_ PIIILADELPIIIA ELECI'RIC COMI%NY P12CilllOrlOM A1DMIC POWER STArlON R. D.1, um 208
--4; hij Delta, lYnnsylvania 17314 nun sormu-.ms romu or ncstam pl7) 45G7014 D. B. Miller, Jr.
Yke President May 13, 1992 Docket Nos. 50 277 50-278 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
SUBJECT:
Peach. Bottom Atomic Power Station Monthly Operating Report Gentlemen:
Enclosed are twelve copies of the monthly operating report for Peach Bottom Units 2 and 3 for the month of April 1992 fonvarded pursuant to Technical Specification 6.9.1.d under the guidance of Regulatory Guide 10.1, Revision 4.
Sincerely, Ak im 476
/
DBM/AAF/1 N DRM/MJB: cmc Enclosure cc:
R.A. Burricelli, Public Service Electric & Gas T.M. Gerusky, Commonwealth of Pennsylvania JJ. Lyash, USNRC Senior Resident Inspector R.I. McLean, State of Maryland T.T. Martin, Administrator, Region I, USNRC H.C. Schwemm, Atlantic Electric C.D. Schaefer, Delmarva Power lINPO Records Center CCOWLNRC 920S190306 920430
'POR ADOCK 05000277
- q R
PDR f
1-NRC Monthly Operations Summary lT Peach llottom Atomic Power Station April 1992 ME.2 Unit 2 began the month shut down as a result of the reactor water level instrument problera that occurred last month. Unit 2 returned to service on April 5 but was manually shat down on April 7 when a one inch vent line o!T the condensate header failed. Following repairs, the unit was returned to senice but was shut down within hours due to a steam leak on a recombiner flow control transmitter. Repairs were completed and the unit returned to senice on April 10. Noatinal 100% power was reached on April 12 and remained at that level for the rest of the month.
UNIT 3 Unit 3 began the month at nominal 100% power wil t no major evolutions. On April 12, p(wr was reduced to l
72% to perform cor: trol rod scram time testing and PCIS testing. Power returned to 100% following testing and remained at that level for the rest of the month.
A progrevive leak on the "P moisture separator drain tank manway is being monitored. A six day outage is scheduled to begin on May 4 to effect repairs.
i CC0f/2.NRC
m h
3-
- -w Docket No. 50-277 Attachment to Monthly Operating Report for April 1992 UNIT 2 REFUEL.lFG INFORM ATION 1.
Name of facility:
Peach Bottom Unit 2 2.
Scheduled date for next refueling shutdown:
Reload 9 scheduled for September 12,1!x)2.
3.
Scheduled date for restart following refuelirg-Restart following refueling forece t for November 30,1992.
4,
- Will refueling or resumption of operation therefore require a technical specincation change or other license amendment?
. No, If answer is yes, what, in general, will these be?
5.
Scheduled date(s) for submitting proposed licensing action and supporting informatiem N/A 6.
Important licensing considerations associated with refueling, e.g., new or different fuel design or supplier, unrevicwed design or performance anahsis methods, significant changes m fuel design, new operating procedures:
- N/A COM92.NRC
L Docket No. 50-277 Attachment to Monthly Operating Report for April 1992 Page 2 UNIT 2 REFUEL.ING IN'. ORh.aTION (Continued) 7.
The number of fuel assemblics (a) in the core and (b) i; the spent fuel storage gwl:
(a)
Core - 764 Fuel Assemblics (b)
Fuel Pool 1896 Fuel Assemblics,58 Fuel Rcds 8.
The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies:
The spent fuel pool storage capacity lias been relicensed for 3819 fuel assemblics.
9.
The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present capacity:
September 2003 without full core offload capability.
September 1997 with full core offload capability.
COM92.NRC
L Docket No. 50-278
' Attachment to Monthly Operating Report for April 1992 UNIT 3 REFUELING INFORMATION
../
1.
Name of facility:
Peach Bottom Unit 3 2.
Scheduled date for next refueling shutdown:
Reload 9 scheduled for September 4,1993 3.
Scheduled date for restart following refueling Restart following refueling scheduled for October 29,1993 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
No If answer is yes, what, in general, will these be?
1 N/A 5.
Scheduled date(s) for submitting proposed licensing action and supporting information:
N/A
-6.
Important licensing tonsiderations associated with refueling, e.g., new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design, new operating i
- procedures:
N/A COM92.NRC 1
l
i ;-
Docket Ne.4L278 Attathment to Monthly Operating Report for April 1992 Page 2 WIT 3 REFUELING INFORRELos (continued; 7.
The number of fuel assemblies (a) in the core and (b) in the spent fuel storage pool.
(a)
Core - 764 Fuel Assemblies (b)
Fuel Fool - 1945 Fuel Assemblies,6 Fcel Rods
- 8. -
The present liensed spent fuel poc! storage capacity and the si7e of any increase in license -.toraFC capacity that has been requested or is planned, in numiser of fuel assemblies:
The spen: fuct pool atoragt capacity has been reticensed for 3819 fuel assemblics.
9, T!.: proPeted date cf the last refueling that can be discharged to the spent fuel pool assuming the present capacity:
Septemler 2004 without full cor( offload capability.
September 1998 with full core eftload capability.
~
CGW1NRC
hi AWRAGE DAILY UNii PWER LEVEL i
DOCKET NO. 50
- 2/7 UNIT PEACH BOTTOM UNIT 2 DATE MAY 15, 1992 COMPANY PHILADELPHIA ELECTRIC COMPANY M. J. BARON SUPERVISOR REPORis CROUP PEACH BOTTOM AT(EIC PWER STATION YELEPHONE (717) 456 7M 4 EXf. 3321
--j.
MONTH APRIL 1992
- DAY AVERACE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (hWE-NET)
(MWE NET) 1 0-17 1053 2
0 18 1065 3
3-19 1051 4
0 20 1043 5
13 21 1056
(
6 640 22 1047 i
7 414 23 1068 8-5 24 1059 9'
0 25 1063 10' 532-26 1059 11 1042" 27 1057 12 -
1065 28-1069 13-1064 29 1096 14 1065-30 1025 15
-1062 16 '
1061
4 AVERAGE DAILY UNIT POWER LEVEL-DOCrFT No. 50 - 278 UNIT PEACM COTTOM UNIT 3 DATE MAY 15, 1992 COMPANT PHILADELPHIA ELECTRIC COMPANT M. J. BARON t
SUPERVISOR REPORTS GROUP PEACM BOTTOM ATOMIC POWER 51 AT10N TELEPHONE (717) 456-7014 EXT. 33?1 MONTH-APRIL 1992 A
DAY AVERAGE DA!LY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-NET)
(MWE* NET) 1 1066 17 1055 2
1054 18 1059 3
1069 19 1061 4
1076 20 1064 5
1029 21 1077 6
1062 22 1065 If 7
1059 23 1065 6
8 106L 24 1052 9
1D56 25 1063 10 1004 26 1055 11 9 74 27 1057 12 1067 25 1057
'13 1065 29 1055
+
14 1058 30 1063 15 1064 16 1055
. _.. ~ - -
n.
r m
c : 4,.
1 gy 5'
~
f A _..,.
J
+
- T 7 tMy J
+
..?-
~-
1.E.;
?
in>am
")' 'l_ Y " ',' ' i sOPERATING DATA REPORT -
7; fo O
L DOCKET Wo. 50 5 277'
= {
{
~
DATE. MAT. 15, 1992 -
..........L...'...............
, o l$
1 COMPLffED BY PHILADELPNTA ELECTRIC COMPANY
.f a ?
3 N. J. BARDW SUPERVISOR REPORTS GROUP I
s
^ *
'PEACN SOTTOM ATOMIC POW 7R STAfl0N TELEPHONE (717) 456 7014 EXT, 3321 c
.0PERATING STATUS m.
ff?
- 11. DNIT KAME: PEACH BOTTOM UNIT 2-NOTESI-y[
[
- 2. REPORTING PERIOD:
APRIL, 1992 pi 3i LICENSED THERRAL POWER (MWT):
3?93 1
j,
~4.'NAME MATC RATING (GROSS MWE):
- 1152
~
~
1065-
'5. DESIGh ELfCTRICAL" RATING (NET MWE) -
t 6.' MAXIMUM DEPEMDASLE CAPACITY (GROSS MWE)t -1098 l
- 7. MAXIMUM DEPEND 48LE CAPACITY (NET MWE):
55.
4................
- 8. IF CHANGES.0CCUR. IN CAPACITY RATINGS '(ITEMS WUMBER 3 THROUGH.7) SikCE LAST REPORT, CIVE RE ASCtist
-9.~ POWER LEVELLTO WHICM RESTRICTED, IF ANY (NET MWE):
i L_
.104 REASONS FOR RESTRICTIONS, IF ANY7 THis MONTH YR To DATE:
CUMULATIVE I
111.~ NOULS 1h REPORTING' PERIOD 719 2,903 156,239-
--[J(
t.12. NUNS &R Of h00RS REACTOR WAS CRITitAL '
542.0.
2,610.0 94;864.0
,a s
- 13. REACTOR RESERVE $NUTDOWN NOURS.-
0.0 0.0 0.0
- 14. NOURS GENERATOR ON LINE 542.0 :
2,610.0 91,447.5
?
d ?-
~ 15, UN!T RESERVE SRUTDOWN HOURS 0.0 0.0 0.0 p,
".16. ' GROSS THERMAL ENERGY, GENERATED (MWH)'
1,714,872 1 8,447,640 270,987,369-t
- 17. GROSS ELECTRICAL ENERGY GENERATED NWH) 566,800
-2,822,100 89,110,690
- 18. NET ELECTRICAL-ENERGY GENERATED (n.3) 545,822 2,739,028-85,356,261 PAGE 1 0F 2 1
'7*
r w e
f--
- W T g
(
y:
G-1 Ei.:'
OPERATING DATA REPORT (CONTINUED)
DOCKET NO. 50
- 277 DATE MAY 15, 1992 THIS MONTM YR TO-DATE CLMULATIVE 19;' UNIT SERvlCE FACTOR 75.4 89.9 58.5
- 20. L'Wii AVAILABILITT FACTOR 75.4 89.9 58.5
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 72.0 89.4 51.8
- 22. UPlT C8.PACITY FACTOR (USING DfR NE')
71.3 88.6 51.3
- 23. UNIT FORCED OUTAGE RATE 24.6 10.1 14.5 c...........
- 24. SdJTDOWNS % HEDULED CVER NEXT 6 MONTHS (TtPE, DATE, AND DURA!!ON OF EACH):
Refuel, 9/12/92 start, 80 days
- 25. IF $HUTDO.Al AT END OF kEPORT perla), E$flHATED DATE Or STARTUP: N/A i;
- 24. UNITS IN TEST STATUS (PRIOR To COMMERCIAL OPERATION):
FORECAST ACHIEVED INITIAL CRITICALITY 09/16/73 INITIAL ELECTEIClif 02/18/74 COMMERCIAL OPERATION 07/05/74 4
PAGE 2 0F 2
gv in " + o w.
7__,.
i uQ @ n gM V'i g '
':p j,4 M-I-
't 3
OPERATING DATA REPORT:
1 t
_g.
Q, DOCKET NO. 50 i 278I
^
- DATE MAY 15, 1992' 1
COMPLETED GT PHILADELPHIA ELECTRIC COMPANT
. M.
J.' SARON
-7 SUPERV!SOR-s REPORTS GROUP PEACH 90TTOM ATOMIC POWER STATION TELEPHONE (717) 456 7014 EXT. 3321-
- OPERATING STATUS -
-1.' UNIT NAME: PEACH BOTTOM UNIT 3 NOTES:
j
- 2.. REPORTING PER100:1 APRI', 1992.
i 7p 13 L Ll';ENSED THERMAL' PC.WER(MWT): --
3293-i
- 4. NAMEPLAIE RATING (GROSS MWEin' 1152
- 5. DESIGN ELECitlCAti RATING WET MWE):
L1065
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 1D78 TiMAX1HuhEEPENDA8LECAPACITY'(NETMWEin 035-8..lF_ CHANGES OCCUR _lW CAPACITY RATINGR (ITEMS WUMBER 3 !HROUGH 7) SINCE LAST REPORT, GIVE REASONS -
i e
,9. POWER f.EVEL TO WHICH RESTRICTED, IF ANY (NET MWE):
d
- 10s REASCMS FOR RESTRICTIONS, IF ANT -
-THIS MONTH-'
.YR TO DATE
-CUMULATIVE-
.11. HOURS IN REPORTING PERIOD--
719; 2,903' 152,135-
-12.-NUMBER pc HOURS REACTOR WAS CRITICAL 719.0 2,876.6
'93,233.7
+
.13. AFACTOR RESERVE CHUTDOWN HOURS 0.0:
0.0
' 0.0,
- 14. HOURS GENERATOR ON*LINE 719.0.
2,700.4 90,005.4-
- 15. Ut!T RESERVE SHUTDOWN HOURS-
- 0.0.
0.0 0.0' Y
y
'16. GROSS THERMAL'ZhERGY GENERATED (WWH).
2,352,072
- 8,229,336-264,323,266
~
l,
-17. GROSS ELECTRICAL ENERGY GENERATED (MWH)
M3,500'
,2,746,600 86,749,132
- 7.
- 18.' NET ELECTRICAL ENERGY GENERATED (MWM) 759,644 2,666,091
'83,149,108 Y
PAGE 1 0F 2 i.
I f:
j f.
i I UJ
-. k
'D b
e p
e.
Ni'
, - - _ _. -......_..__._... ~. -
DOCKET NO. 50 278 OPERATING DAT A REPORT (CONTINUED)
I i
DATE MAY 15, 1992 THis MONTH YR*TO-DATE CUMULATIVE 39.2 100.0 93.0
- 19. UNIT SERVICE FACTOR 100.0 93.0 59.2
- 20. UNIT AVATLABILITT FACTOR 102.1 88.7 52.8
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 51.3 99.2 86.2
- 22. UNif CAPACIT) FACTOR (USING DER NET) 12.4 0.0 0.5
- 23. UN!? TORCED CUTAGE RATE
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DAir, AND DURATION O None N/A 2$. IF SHt1L,0WN AT END OF REPORT PERl(D ESTIMATED DATE OF STARTUP:
FORECAST ACHIEVED
08/07/74 INITIAL CRITICALITY 09/01/74 INITIAL ELECTRICITY 12/23/74 COMMERClAL OPERAT10N PACE 2 0F 2
"-"'%m
' " * = ~ ~ _ -, _
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50
- 277 j.
UNIT NAME PEACH BOTTOM UNIT 2 DATE MAT 15, 1992 REPORT MONTH APRIL, 1992 COMPLETED BYi ADELPHIA ELECTRIC COMPANY M. J. BARON -
SUPERVISOR REPORTS GROUP PEACH BOTTOM ATOMIC POWER STATION I
TELEPHONE (717) 456-7014 EXT. 3321 METHCC OF LICENSEE SYSTEM COMPONENT CAUSE AND CORRECTIVE TYPE DURATION REASON SHUTTING DOWN EVENT CCCE CODE ACTION TO NO.
DATE-(1)
(kOURS) : (2)
REACTOR (3)
REPORT #
-(4)
(5)
PREVENT RECURRENCE 4
920401 F
116.0 A
1 2 92 05 ID INSTRU UNIT SRUT DOWN DUE TO REACTOR WATER LEVEL MISMATCH 5
920407-F 32.0 A
1 2-92-06 NH PIPEXX CONDENSATE VENT LINE FAILURE 6
920408 F
29.0 A
1 NA PE RFCOMB STEAM LEAK ON RECOMBINER FLOW TRANSMITTER 177.0 (1)
-(2)
(3)
(4) a'
$1 iiCTp00 EXHIBIT G - INSTRUCTIONS F. FORCED S~~
SCHEDULED A
'UIPMENT FAILURE (EXPLAIN) 1 - MAKUAL FOR PREPARATION OF DATA B. MAINTENANCE OR TEST 2 - MANUAL SCRAM.
ENTRY SHEETS FOR LICENSEE C - REFUELING 3 AUTOMATIC SCRAM.
EVENT REPORT (LER)
D.-
REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)
FILE (NUREG 0161)
E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATlvE (5)
G
- OPERATIONAL ERROR (EXPLAIN)
H - OTHER(EXPLAIN)
EXHIBIT 1 - SAME SOURCE
n% y.
r 1: '
au gf? q.-
+-
4 '
-1 4
y - -
s M
LUNIT. SHUTDOWNS AND POWER REDUCTIONS-
' DOCKET NO. 5'O, 278 i
UNIT NAME PEACN SO TOM UNIT 3 4.....
DATE MAY 15, 1992 -
REPORT MONTN-APRIL, 1992
. COMPLETED BY PHILADELPHIA ELECTRIC COMPANT M. J. BARON n -
SUPERVISOR r
1
REPORTS GROUP
- PEACHBOTTOMATOMICPOWERSTAflDi TELEPHONE _(717) 456*7014 EXT. 3321
-...........J.........................'........................................................................................
- METHOD OF-
' LICENSEE STSTEM COMPOWENT' CAUSE AWD CORRECTlW
=q t.
TTPE DURATION REASON SHUTTING DOWN EVENT CODE CODE
' ACTION TO NO.
DATE-(1) l'(HOURS) s(2)
REAC10R (3)
REPORT #-
-(4)
(5)
PREVENT RECURRENCE
~
jj:
.R j.920410
.S
_ 0.0 :
B 4.
NA CD '
VALVEK' MSIV TESTING REACTOR WAS NOT SHUT DOWN
<h (m
.g
,1 s
4 Gs..,
7 b).
. (2).-
-(3)
(4)-
s FORCED-REASON'
- METH(V EXHIBIT G'-
thSTRUCTIONS
'$4 SCHEDULED' ' A.* EQUIPMENT FAILURE (EXPLAIN}-
1 - MANUAL.
.FOR PREPARATION OF DATA -
.C4 MAINTENANCE OR TEST--
2.- MANUAL SCRAM.
FNTRT SHEETS FOR LICENSEE p',
C - PEFUELING ~
3.- AUTOMATIC SCRAM.
' EVENT REPORT (LER) p.- REGULATORY RCSTRICTION-4 - OTHER (EXPLAIN)
TILE (NUREG 0161)
E - OPERATOR 1 RAINING + llCENSE EXAMINAT!ON'-
Ff~ ADMINISTRATIVE
.(5)
=
G -:0PERATIONAL ERROR (EXPLAIN).
- H - OTHER(EXPLAlW)e EXHIBIT 1 SAME SOURCE.
L 1_
_