KANSAS GAS AND ELECTRIC COMPANY T&E ELECTAC COMPANY GLENN L NOESTER vect enssiormT-mucLEa#
August 8, 1984 Mr. D.R. Hunter, Chiefgg]g] Reactor Project Branch 2 U.S. Nuclear Regulatory Commission Region IV AUG I 31984 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 I KMLNRC 84-138 Re: Docket No. STN 50-482 Subj: Potential 10CFR50.55(e) Final Report - Reactor Vessel Level Instrumentation System
Dear Mr. Hunter:
This letter provides the final report on a potential 10CFR50.55(e) con-cerning an incorrect differential pressure correction in the Reactor Vessel Level Instrumentation System (RVLIS). This matter was initially reported by Mr. H.K. Chernoff of Kansas Gas and Electric Company (KG&E) to Mr. William McNeil of the Nuclear Regulatory Commission, Region IV, on April 27, 1984. During scaling of the RVLIS, an error was detected in the temperature / differential pressure correction for the RVLIS tubing. This error was caused by a RVLIS tubing modification made by the Architect Engineer (A/E) during construction. The A/E had added an additional vertical rise and drop to the RVLIS tubing, which changed the differential pressure correction for the tubing. To remedy this situation, the input circuitry for the RVLIS into the 7300 process cabinet was reworked to correct the sign of the density correction summing. This corrective action has now been completed and the RVLIS tubing has the proper differential pressure correction. If you have any questions concerning this matter, please contact me or Mr. Otto Maynard of my staff. Yours very truly, f/fu GLK:bb xc: RCDeYoung PO'Connor HBundy 8408220479 840808 PDR ADOCK 05000482 S PDR H-17 201 N. Markst - Wictuta, Kansas - Mail Address: RO. Box 208 i Wichita, Kansas 67201 - Telephore: Area Code (316) 261-6451}}