M.'.Burski W3F1-92-0143 A4. 05 QA 1

April 17, 1992 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382

)

License No NPF-38 i

NRC Inspection Report 92-06 Reply to Notice of Violation Gentlemen:

In accordance.with 10CFR2.201, Entergy Operations, Inc. hereby submits in Attachment I the response to the violation identified in Appendix A of the subject Inspection Report.

In addition to corrective actions to be taken in response to the violation, further action is being taken in an effort to enhance Waterford 3's boric acid corrosion program. First, Administrative Pcocedure UNT-007-027, " Control of Boric Acid Corrosion on the Reactor Coolant System", will be revised to require that inspection reports include a. listing of all condition identifications generated as a result of the boric acid corrosion inspections. Secondly, the reactor coolant system components identified in an internal memo (dated May 17, 1988) as being potentially susceptible to boric acid corrosion will be reevaluated for inclusion in the boric acid ccerosion program. These enhancements are scheduled for completion by August 15, 1992.

If you have any questions concerning this response, please contact B.R. Loetzerich at (504) 730 -G636.

Very truly yours,

/

m

,f' h/

i..t

?

RF

/e q#dM8 ac)rfne

/c /,-

R.D. Martin, NRC Region IV c/

D.L. Wigginton, NRC-NRR R.B. McGehee 8([

N.S. Reynolds NRC Resident inspectors Office

/* l l

o n..,

9204'210302 9I20417 PDR ADOCK 05000392 0

PDR

l Attachment to -

- 4 W3F1-92-0143 C

Page 1 of 2 c

ATTACHMENT _1 ENTERGY OPERATIONS, INC. RESPONSE TO THE VIOLATION IDENTIFIED IN APPENDIX A OF INSPECTION REPORT 92-03 VIOLATION NO. 9206-02

-10 CFR 50, Appendix B, Criterion V, requires that activities affecting quality shall be prescribed by and accomplished in accordance with documented instructions, procedures, or drawings, of a type appropriate to the circumstances.

Paragraphs 5.1'.5 and 5.2.1 of Administrative Procedure UNT-007-027, Revision 1, state, respectively, "A condition identification shall be generated to identify the leak, accomplish repair and evaluate the impact on the Reactor Coolant System (RCS) pre ssure boundary", and " Engineering Evaluations shall be performed on all boric acid leaks identified in areas noted on Attachment 6.1".

Contrary to the above, during the performance of a boric acid leak monitoring walkdown in the period March 16 through May 5,1991, three valves (SI-332 A and SI-401 A &.B) were observed by walkdown personnel to_ exhibit boric acid crystal buildup. There was no evidence that either the required condition identification was generated, or that an engineering evaluation was performed.

This is a. Severity Level IV violation (382/9206-02).

-RESPONSE

'(1)

Reason for the Violation Entergy' Operations, Inc. admits this violation and believes that the root cause is procedural inadequacy. Administrative Procedure UNT-007-027,

" Control of Boric Acid Corrosion 'on the Reactor Coolant System", requires that for each identified leak, a Condition Identification (CI) must be initiated and an engineering evaluation performed. : However, a clear definition of identified leakage is needed within the procedure to indicate the specific actions required for certain observed conditions.

3 UNT-007-027 req'uires that Plant Engineering personnel perform the boric acid corrosion hunections. The engineer who performed the visual

' examinatluns during the subject walkdown was familiar with the j-characteristics and oparation of safety injection valves SI-332 A, SI-401 A

~

and SI-401 B. The engineer observed the presence of boric acid crystals on the stem and packing gland of three safety injection valves. _ The engineer documented the observations in his inspection report, and specifically noted that the suspect areas were dry and that no corrosion existed.

l-l ra ww

--7rg

--f'T'W sW T

g-

  • 'N
    • 'F*r 4" " * -

rW=

f n-g

-C-d.-

L

-wr v a e e.*

w

Attachment to W3F1-92-0143 Page 2 of 2 The engineer did not consider the observed conditions to be indicative of identified leakage; rather, he considered the horic acid crystals to be

~

typical of valve actuation. Given the physical characteristics of the valves (size, stem to packing construction, etc.), cycle of operation and the abserved conditions of the crystals, the engineer concluded that further evaluation was not required for the safety injection valves, Therefore, a Ci was not generated based on a field evaluation that no further actitns were required. Although a later inspection confirmed the original field evaluation, a conflict existed with the governing proci dure which lacked a clear definition of identified leakage which indicates required actions for certain observed conditions.

(2)

Corrective Steps That flave Been Taken and the Results Achieved t

Plant Engineering performed another boric acid corrosion inspection

-during tue period of February 17 through February 23, 1992. The inspection report concludes that the observed conditions of the three safety injection valves are not indicative of boric acid leakage. As such, no immediate corrective actions were required.

(3)

Corrective Steps Which Will Be Taken to Avoid Further Violations Plant Engineering will revise UNT-007-027 to clarify the definition of identified boric acid leakage and provide the inspection engineer with detailed instructions for required actions dependant upon the leakage conditions encountered.

(4)

Date When Full Compliance Will Be Achieved i-The procedural revision discussed per item (3) above shall se completed by F

August 15, 1992.

a b