ENERGY Donald C. SheMon 300 Madison Avenue Vce President Nudes Toledo, OH 436520001 Davis Besse M242300 Docket Number 50-346 License Number NPF-3 Serial Number 2035 April 14, 1992 United States Nuclear Regulatory Commission Document Control Desk
-Vashington, DC 20555 s
Subj ec t : Withdrawal of Request for Temporary Vaiver of Compliance f rom Technical Specification 3.4.11 (Reactor Coolant System -
Reactor Coolant System Vents) l Gen t le.aen; j
Toledo Edison, by letter dated March 13, 1992 (Reference Serial Number 2026), submitted an application for an amendment to the Davis-Besse Nuclear Pover-Station (DBNPS), Unit 1 Operating License Number NPF-3 Appendix A, Technical Specifications (fS), proposing changes involving TS 3.4.11, Reactor Coolant System - Reactor Coolant System Vents, and-TS 6.9.2,-Reporting Requirements - Special Reports.
The Reactor Coolant System (RCS) Loop 2 vent path became inoperable on March 1, 1992, when it was manually isolated by valve RC 44-to minimize rotential RCS leakage. To avoid an unwarranted plant shutdown in the j.
event that the inoperable RCS Loop 2 vent path could not-be returned to l-
- operable status within the 30 day allowed outage time of TS 3.4.11, Toledo Edison requested that this license amendment application be processed in the manner alloved by 10-CFR 50.91(a) for exigent or emergency circumstances.
l Toledo Edison, by letter dated March 20, 1992-(Reference Serial Number 2032), also submitted a request for a Mmporary valver of compliance with TS Action 3.4.11.a to allow the plant to continue operating in Mode 1 while the previously submitted application for a license amendment was processed.
Toledo Edison has kept the Nuclear Regulatory Commission (NRC) staff-informed (by telephone) of its ef forts to restore the affected RCS Loop 2 vent path to operable status.
On March 25, 1992, the RCS Loop 2 vent path solenoid valves RC 4610A and RC 4610B vere stroked (from the control room) to ensure a proper seating.
On March 26, 1992, a o
L containment entry was made to open upstream manual valve RC 44.
No discernible leakage,from RC 4610A and RC 4610B vas observed at that timo.
Therefore, Valve RC 44 was left opea and the TS 3.l.11 Action
~
. statement was exited at 0922 hours0.0107 days <br />0.256 hours <br />0.00152 weeks <br />3.50821e-4 months <br /> on March 26, 1992.
Ba ul on the opemnpa co 9204210204 920414 I
y cieveiqreMehces @nng
@d POR ADOCK 0500 6
?
Tofedo Ed: son P
l:
... - - =.
Docket. Number 50-346 License Number NPF-3 Serial Number 2035-Page 2
'above, Toledo Edison notified NRC Office of Nuclear Reactor' Regulation (NRR) Project Directorate III-3 Director J. N. Hannon by telephone on March 30, 1992, that the request for a temporary valver of compliance was withdrawn, and that exigent or emergency processing of the license amendment application was no longer required. However, Toledo Edison requests that the proposed license amendment application be processed in an expeditious manner.
Toledo Edison vill be contacting the'NRC staff shortly with regards to providing requeste' information.
concerning the continuous vent line.
In the meantime, should further information be required, please contact Mr. Robert V. Schrauder, Manager - Nuclear Licensing, at (419) 249-2366.
Very truly yours, is
~(:7 e
v'\\.e v ^ N m MKL/vab cc:
A. S. Davis, Regional Administrator, NRC Region III J. B. Hopkins, NRC/NRR DB-1 Seniot Proj ec t Manager l
V. Levis, NRC Senior Resident Inspector J. R. Williams, Chief of Staff, Ohio Emergency Management Agency,.