Part 21 Rept Re Tension Wires Used for Adjustment of Blades on Grille Model 272 Not Remaining in Place When Blades Closed.Review & Testing Conducted to Identify Number of Grilles & Rework Methods to Be Utilized
ML20094Q807
Person / Time
Site: Palo Verde  
Issue date: 08/07/1984
From: Stewart Schneider
AFFILIATION NOT ASSIGNED, PHILLIPS INDUSTRIES, INC.
To: Strait R
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
REF-PT21-84-419-000 DERF-840807, PT21-84-419, PT21-84-419-000, NUDOCS 8408200333
Download: ML20094Q807 (1)


Text

B S

  • MONG a

aaos curitr o-Richardson, Texas 75081 Division of Philips Industries Inc.

Manufactunng Quality Components for Better Building.

August 7, 1984 Palo Verde Nuclear Generating Station Units I, II, and III P.O.

Box 215 Buckeye, Arizona 85326 Attention:

Robert Strait Project Engineer Subj ect:

Model 272 Grille, Tension Wires It has recently come to our attention that some of the tension wires used for adjustment of the blades on Grille Model 272 will not remain in place when the blades are closed.

A review is being conducted for the total number of grilles supplied and will be forthcoming identifying the total scope.

Testing is being conducted to identify rework methods to be utilized.

Upon completion Titus will schedule personnel to complete rework.

Titus Products has notified the Nuclear Regulatory Commission of this situation in accordance with the requirements of 10 CFR Par t 21.

We will be contacting you with further information and making arrangements to rework the subject grilles.

Sincerely, TITUS PRODUCTS DIVISION Steven L.

Schneider President cc:

Ned Ryan Marv DeHart Richard Yarges 0408200333 840807 PDR ADOCK 05000528 6

PDR 9

i O LASCO DIVISION *LAU DIVISION

  • MALTA DIVISIONeMANUFACTURED HOUSING / RECREATIONAL VEHICLE GROUP RUSKIN OlVISION*TITUS PRODUCTS DIVISION

..