'n.
GPU Nuclear Corporation Nuclear
=.it; 88 Forked River, New Jersey 08731-0388 609 971-4000 Wnter's Direct Dial Number:
November 14, 1995 C321-95-2338 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 1
Dear Sir:
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219
. Monthly Operating Report - October,1995 In accordance with the Oyster Creek Nuclear Generating Station Operating License No. DPR-16, Appendix A, Section 6.9.1.C, enclosed are two (2) copies of the Monthly Operating Data (gray book information) for the Oyster Creek Nuclear Generating Station.
If you should have any questions, please contact Brenda DeMerchant, Oyster Creek Licensing Engineer at (609) 971-4642.
Sincer ly, S
J 'hn J. Ba, ice Presi nt and Director Oyster Creek JJB/BDEM Attachment cc: ' Administrator, Region 1 Senior NRC Resident Inspector Oyster Creek NRC Project Manager
$d0090 9511300170 951031
(
PDR ADOCK 050 29
,E --
--~gp0 Nuclear Corporation is a subsidiary of General Public Utilities Corporation
SUMMARY
October,1995 Oyster Creek operated the entire month at full power. During the month, the plant generated 468,215 net MWH electric and attained a MDC net capacity factor of 101.5 %.
l I
MONTIILY OPERATING REPORT
\\
LICENSEE EVENT REPORTS j
.No LER's were submitted during the month of October 1995.
d 1
i
f Oyster Creek Station #1 Decket No. 50 219 REFUELING INFORMATION. OCTOBER,1995 Name of Facility: Syster Creek Station #1 Scheduled date for next refueling shutdown.
i September,1998 Scheduled date for restart following refueling: Currently projected for
+
November,1998 Will refueling er resumption of operation thereafter require a Technical Specification change er other license amendment?
Ne Important licensing considerations associated with refueling, e.g., new or different fuel design er supplier, unreviewed design er performance analysis methods, significant changes in fuel design, new operating precedures:
1.
General Electric Fuel Assemblies Fuel design and performance analysis methods have been approved by the NRC.
The number of fuel assemblies (a)in the cors 580
=
(b) in the spent fuel storage pool
- 2048 (c) in dry storage 24
=
The present licensed spent fuel peel storage capacity and the size of any increase in licensed storage capacity that has been requested er is planned, in number of fuel assemblies:
Present Licensed Capacity: 2845 The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:
Full core discharge capacity to the spent fuel peel will be available through the 1998 refueling outege.
. (pndocs-95\\$414-95\\opdata.cor\\ report 30)
AVERAGE DAILY POWER LEVEL NET MWe DOCKET #........... 50 219 UNIT........ 0YSTER CREEK #1 REPORT DATE........11l8195 COMPILED BY........ PAUL EDELMANN TELEPHONE #...... 809 9714097 MONTH: OCTOBER.1995 RAI M
HA1 M
1.
831 18.
832 2.
831 17, 833 3.
830 18.
833 4.
824 19.
831 5.
823 20.
828 8.
820 21.
823 1
7.
824 22.
633 S.
825 23.
830 9.
830 24.
829 10.
828 25.
828 11.
828 28.
831
)
12.
828 27.
831 a
13.
828 28.
828 14.
823 29.
832 15.
825 30.
835 31.
835 (p:\\ docs-95\\5414-95\\opdata.cor\\ report:31)
OPERATING DATA REPORT OPERATING STATUS 1.
DOCKET:
50 219 2.
REPORTING PERIOD: Oct 95 3.
UTILITY CONTACT: PAUL EDELMANN (808-9714097) 4.
LICENSED THERMAL POWER (MWt):
1930 5.
NAMEPLATE RATING (GROSS MWe): 887.5 x 0.8 = 550 8.
DE81GN ELECTRICAL RATING (NET MWe): 850 7.
MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 641 8.
MAXIMUM DEPENDANLE CAPACITY (NET MWe): 819 9.
IF CHANGES OCCUR AB0VE SINCE LAST REPORT, GIVE REASONS:
NONE
- 10. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWe):
NONE
- 11. REASON FOR RESTRICTION,IF ANY:
NONE MONTH YEAR CUMULATIVE
- 12. REPORT PERIOD HOURS 745.0 7296.0 228656.0
- 13. HOURS RX CRITICAL 745.0 7298.0 153096.7
- 14. RX RESERVE SHUTDOWN HRS 0.0 0.0 918.2
- 15. HR$ GENERATOR ON LINE 745.0 7296.0 149595.1 i
{
l
- 17. GROSS THERM ENERGY (MWH) 1438449 13741450 258265154 i
i
- 18. GROSS ELEC ENERGY (MWH) 485706 4624925 86651216
- 19. NET ELEC ENERGY (MWH) 468215 4457891 83132778 i
4
- 20. UT SERVICE FACTOR 100.0 100.0 66.0
- 21. UT AVAIL FACTOR 100.0 100.0 86.0 i
- 24. UT FORCED OUTAGE RATE 0.0 0.0 9.8
- 25. FORCED OUTAGE HRS 0.0 0.0 16289.8
- 28. SHUTDOWNS SCHEDULED OVER NEXT 8 MONTHS (TYPE, DATE, DURATION):
NONE
- 27. IF CURRENTLY SHUTDOWN, ESTIMATED STARTUP DATE: NlA I
(pMocs 95\\5414-95bpdata.cor\\ report:32) 4
'i
.I
, i 4
'3
, i,
4 s
6 4
h
( S R
- d. c..b a 1 U E
) l P
t 1
O RA R
RRME ER T
eeaq AY g fiu Sh M
- u. uni O
N O
letp N
o.
N alem T
t ine H
onan rg nt y
c eF R
a e
oi O
s rl c
t u
t r
Tr o
i ee b
c s
e t
t (
r i
E o
x D
1 n
p A
9 l
T 9
a E
5 in
-)
.h g f e.
SF OOAO tp dp SF heme co erir hr rana ec t it deT
( is o udY Eot r l
P xnr e
E p aaT d
llt r a
ia iEvi nren
) r i
o n
r g
U
(
N E
I x
L T
p i
l e
S a
H h
i U
n T
)
D D
m U
O
(
h R
W oA N
u T S
r I
s O
A
)
N ND P
(
O 4 3 212 W
)
ER OAMMM R
t uaa E
E ht nn T
D eouu H
U rmaa O
R C
allD E
T
( t A
I EiS S
O xcc O
N p
r N
lSa TCDUD S
EOANO acm
(
LMTIC ir 1
EPETK na
)
m PL:
E
)
HT NT O
- A ND MN E
- B RDM Y
EOE DWT UNH C
O ITD 9
D N O 5
NH 7
a o
y 0
GEO 1
v v s
F i
e t
2 PR 4
d m e 1
OES 8
b r
9 M e WAH 1
ECU 8
r C
RTT r
OT E
0 e
( RI r
9 e
2 N
a k
OG n
)
R 1
9 9
5 p t rssT AC eheihh CO ridg ue TR is unt r IR o
cide OE drt f o NC eiiww ST p ocne
/ I onasr CV rsn e
OE t
t o M
id
- r. n M
nup o
E g ro N
iw T
ne S
g r
!I