ML20094P262

From kanterella
Jump to navigation Jump to search
Forwards Results of Visual Insps of Core Spray Spargers,Per IE Bulletin 80-13.GE Internal Core Spray Line Flaw Evaluation at CNS Also Encl
ML20094P262
Person / Time
Site: Cooper 
Issue date: 11/22/1995
From: Mueller J
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20094P264 List:
References
IEB-80-13, NLS950228, NUDOCS 9511280389
Download: ML20094P262 (3)


Text

..

p yv s.

..o.aoxWaow"uvittTcaE 22 p

Nebraska Public Power District

" E " M ""

i I

NLS950228

~ November 22,1995 L U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Subject:

IE Bulletin 80-13 Response ; Visual Inspection of Core Spray Spargers Cooper Nuclear Station, NRC Docket No. 50-298, License No. DPR-46

Reference:

IE Bulletin 80-13, Visual Inspection of Core Spray Spargers 1

' Gentlemen:

Nuclear Regulatory Commission IE Bulletin 80-13 (referenced above) requires all operating

' licensees of Boiling Water Reactors (BWRs) to perfonn a visual inspection of the Core Spray Spargers and the segment of piping between the inlet nozzle and the vessel shroud every refueling outage. This bulletin also requirca a vaitten report of the examination results to be

- submitted to the NRC within 30 days of the completion of the examinations. In accordance with

'I the requirements ofIE Bulletin 80-13, the Nei;raska Public Power District (District) hereby provides the results of the subject inspections for the Fall 1995 refueling outage. The District requests NRC review and approval of the attached results prior to startup from the current refueling outage, which is currently scheduled to conclude December 19,1995.

The Core Spray Spargers and associated piping were inspected by General Electric (GE) In-Vessel Inspection personnel in accordance with IE Bulletin 80-13 and the approved GE procedure. The lighting was sufficient to resolve a 0.0005 inch diameter wire. Three crack-like indications, and two suspect indications were identified. Supplemental ultrasonic examinations were performed to evaluate these indications. Examination Summary Sheet, R-CS-101, is included as Attachment I to this letter.

{ to this letter provides the GE evaluation of the relevant indications per the fracture mechanics methods of ASME Section XI, Subsection IWB-3600, and demonstrates the structural

~ integrity of the' Core Spray internal piping for at least one more operating cycle. The District will continue to inspect the. Core Spray Spargers and associated piping in accordance with IE Bulletin I

80-13.

2800y 9511230389 951122

/ /[ ~

~

.PDR ADOCK 05000299 n

_PDR -.

h s

7

4 NLS950228 jX l~

November 22,1995 Page 2 of 2 -

Please contact me if you have any questions or require any additional information.

l

. Sincerely, l

J hn 11. Mueller Site Manager

/dnm Attachments cc:

Senior Project Manager USNRC - NRR Project Directorate IV-1 Senior Resident Inspector

.USNRC l

Regional Administrator l

USNRC - Region IV L

NPG Distribution 1

l

to NLS950228 F

REPORT NO.:

Page,1 of 1 EXAMINATION

SUMMARY

SHEET GE Nuclear Energy a CS-10L_.

PROJECTL_ COOPER _N_U_CJ. EAR STATION PROCEDURELULCNS-507VD REVLQ_ FRR: _N/A RFO16 M

SYSTEM:_CORESPRAY

_ REV d A FRR 3'L

_ N/A.____ _.

WELD NO.:_SEEBELOW

..N/A _._._

CONFIGURATION: _SEEBELOW N!A.

REV:_N/A FRR: _ N/A.

_N/A_

N/A EXAMINER:_ NICK 1ABELLA LEVEL:Ji O MT O PT G UT O vT EXAMINER:_ MIKE. WEBSTER LEVEL:_JL

$ CIRCUMFERENTIAL WELD TYPE:

EXAMINER: N/A LEVEL:__N/A_ _.

O LONGITUDINAL O OTHER l

DATA SHEET NO.(S):_D-CSd01.0-CS-102 CAL SHEET NO.(S):_C-CS-101

.D-CSdO3 D-CSdO4

_C-CS-102

.D-CS405. D CS-106

.C-CS-103 1

i The purpose of this report is to provide the final results of the Remote Ultrasonic examinations performed Nov. 3 thru Nov 5,1995 on the internal Core Spray Pl ping. This UY exam was performed to confism the presence or absence of cracking in areas identrfied as cracked or suspect areas by the enhanced IVVI inspections.

l These examinations were performed utilizing the Smart 2000 Data Acquision System and the Core Spray piping examination fixture which utilized 3 seperate 80* refracted longitudinal wave ( OD Creeping Wave ) search units. The examination technique utilized circumferential and axial scanning patterns. All scans were performed with the ultrasonic beam directed perpendicular to the weld.

The exams performed are listed below by component ID and Data report number and includes a summary of results obtained A Loop Weld # 1 @ 170* D-CS-101 Visualinspections had reported a crack like indication located between 190* and 350*. The UT examination detected this crack intermittently between 190* and 350*. It does not appear to be ID connected and appears to be limited to the upper 25% of the base material. The exam was performed for 360* and detected no additional cracking.

A-Loop Weld # 21 @ 10* D-CS 102 Visualinspections had reported a crack like indication located between 270* and 360*. The UT examination detected this crack intermittently between 280* and 350*. It does not appear to be ID connected and appears to be limited to the upper 25% of the base material. The exam was performed for 360* and detected no additional cracking A-Loop Weld # 6 @ 170* D-CS-103 Visualinspections had reported a suspect indication located between 290* and 310*. The UT examination detected no evidence of cracking in this area. The exam was performed for 360* and detected no additional cracking.

B-Loop Weld # 12 @ 270* D-CS 104 Visualinspections had reported a crack like indication 1.5* in length, located between O' and 90*. The UT examination detected no evidence of cracking in this area. The exam was performed from 315* clockwise to 180* and detected no cracking. The proximity of the RPV wall prevented any additional UT examination.

A Loop Weld # 7 @ 170* D-CS-105 Visua! inspections had reported a suspect indication located 360* intermittent on the lower side of this weld. The UT examination detected no evidence of cracking in this area. The UT exam was performed for 360* and detected no cracking.

A-Loop Weld # 15 @ 10' D-CS 106 Visual inspections had reported a non-relevant indication located 360* intermittent on the lower side of this weld. The UT examination detected no evidence of cracking in this area. The UT exam was performed for 360* and detected no cracking.

,R_ //22 ' W

SUMMARY

BY LEVEL DATE J

,- GE REVIEWED BY LEVEL-.- N'N fY

/

PAGEtt_ OF:_11_

DATE NPPD ISI ENG EER EVIEW

. TE

_ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ -.