ML20094M172

From kanterella
Jump to navigation Jump to search
Requests That Proprietary WCAP-14496, Fsv Technical Basis Documents for Piping Survey Implementation Be Withheld from Public Disclosure (Ref 10CFR2.790)
ML20094M172
Person / Time
Site: Fort Saint Vrain 
Issue date: 11/08/1995
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Weber M
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML19317C115 List:
References
CAW-95-898, NUDOCS 9511210303
Download: ML20094M172 (13)


Text

-

{m

~

s l

i l

l Westinghouse Energy Systems Nuclear Technolon myision Electric Corporation su 333 Pittsburgh Pennsylvania 15230-0355 November 8,1995 CAW-95-898 Document Control Desk U.S. Nuclear Regulatory Commission

. Washington, DC 20555 Attention: Mr. Michael F. Weber, Chief Decommissioning and Regulatory Issues Branch APPLICATION FOR WITHHOLDING PROPRIETARY INFORMATION FROM FUBLIC DISCLOSURE J

Subject:

" Fort St. Vrain Technical Basis Documents for Piping Survey Instrumentation",

WCAP-14496, (Proprietary)

.I

Dear Mr. Weber:

The proprietary information for which withholding is being requested in the above-referenced report is further identified in Affidavit CAW-95-898 signed by the owner of the proprietary information, Westinghouse Electric Corporation. The affidavit, which accompanies this letter, sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of 10 CFR Section 2.790 of the Commission's regulations.

Accordingly, this letter authorizes the utilization of the accompanying Affidavit by Public Service l

Company of Colorado.

Correspondence with respect to the proprietary aspects of the application for withholding or the Westinghouse affidavit should reference this letter, CAW-95-898, and should be addressed to the undersigned.

Very truly yours,

)

N. J. Liparulo, Manager Nuclear Safety Regulatory and Licensing Activities Enclosures cc: Kevin Bohrer/NRC (12H5) 95112103o3 951115 PDR ADOCK 05000267 W

PDR t&#x'-BDIA:110895

a 4

A s

a he A

m mn-A J

p

.m4-A e

i e

4 4

1 j

ATTACHMENT 5 l

TO P-95102 s

AFFIDAVIT 4

5 J

e

CAW-95-898 1

AFFIDAVIT COMMONWEALTH OF PENNSYLVANIA:

i l

ss COUNTY OF ALLEGHENY:

Before me, the undersigned authority, personally appeared Henry A. Sepp, who, being by me duly sworn according to law, deposes and says that he is authorized to execute this Affidavit on behalf of Westinghouse Electric Corporation (" Westinghouse") and that the averments of fact set forth in this Affidavit are true and correct to the best of his knowledge, information, and belief:

k sh

<1

(

f

('l Henry A. Sepp, Manager Regulatory and Licensing Initiatives Sworn to and subscribed before me this

\\O day of AfDU4AthoA

.1995 Natans ses Denise K Horderson,obtary PutAc unoem soro. AL county 3_ *r yg pjYfyWp "Y C""*

  • 28
  • Momter. Penneyhrania Assocean of Nutanes Notary Public

\\

l 1844C-Biat:110M3

- - -.. _ _.. -. ~ ~ _ _.... - -

i l

i CAW-95-898 e

(1)

I am Manager, Regulatory and Licensing Initiatives, in the Nuclear Technology Division, of i

the Westinghouse Electric Corporation and as such, I have been specifically delegated the function of reviewing the proprietary information sought to be withheld from public disclosure in connection with nuclear power plant licensing and rulemaking proceedings, and am authorized to apply for its withholding on behalf of the Westinghouse Energy Systems Business Unit.

(2)

I am making this Affidavit in conformance with the provisions of 10CFR Section 2.790 of the Commission's regulations and in conjunction with the Westinghouse application for withholding accompanying this Affidavit.

(3)

I have personal knowledge of the criteria and procedures utilized by the Westinghouse Energy Systems Business Unit in designating information as a trade secret, privileged or as 4

confidential commercial or financial information.

(4)

Pursuant to the provisions of paragraph (b)(4) of Section 2.790 of the Commission's regulations, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld, (i)

The information sought to be withheld from public disclosure is owned and has been i

held in confidence by Westinghouse.

1 (ii)

The information is of a type customarily held in confidence by Westinghouse and not i

customerily disclosed to the public. Westinghouse has a rational basis for determining

?

the types of information customarily held in confidence by it and, in that connection, j

utilizes a system to determine when and whether to hold certain types of information in confidence. The application of that system and the substance of that system constitutes Westinghouse policy and provides the rational basis required.

Under that system, information is held in confidence if it falls in one or more of several types, the release of which might result in the loss of an existing or potential competitive advantage, as follows:

I i

e ISMC BIE-2:110WS

- _, _ _ ~

CAW-95-898 (a)

The information reveals the distinguishing aspects of a process (or component, _

l structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies.

(b)'

It consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), the application of which data secures a competitive economic advantage, e.g., by optimization or improved marketability.

(c)

Its use by a competitor would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing a similar product.

(d)

It reveals cost or price information, production capacities, budget levels, or commercial strategies of Westinghouse, its customers or suppliers.

(e)

It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.

(t)

It contains patentable ideas, for which patent protection may be desirable.

There are sound policy reasons behind the Westinghouse system which include the following:

(a)

The use of such information by Westinghouse gives Westinghouse a 1

competitive advantage over its competitors. It is, therefore, withheld from disclosure to protect the Westinghouse competitive position.

l (b)

It is information which is marketable in many ways. The extent to which such information is available to competitors diminishes the Westinghouse ability to sell products and services involving the use of the information.

l touc-stuttom CAW-95-898 (c)

Use by our competitor would put Westinghouse at a competitive disadvantage by reducing his expenditure of resources at our expense.

l (d)

Each component of proprietary information pertinent to a particular competitive advantage is potentially as valuable as the total competitive advantage. If competitors acquire components of proprietary information, any one component may be the key to the entire puzzle, thereby depriving Westinghouse of a competitive advantage.

(e)

Unrestricted disclosure would jeopardize the position of prominence of Westinghouse in the world market, and thereby give a market advantage to the competition of those countries.

(f)

The Westinghouse capacity to invest corporate assets in research and development depends upon the success in obtaining and maintaining a competitive advantage.

(iii)

The information is being transmitted to the Commission in confidence and, under the provisions of 10CFR Section 2.790, it is to be received in confidence by the Commission.

l l

(iv)

The information soua,ht to be protected is not available in public sources or available l

l information has not been previously employed in the same original manner or method to the best of our knowledge wt belief.

l (v)

The proprietary information sought to be withheld in this submittal is that which is appropriately marked in " Fort St. Vrain Technical Basis Documents for Piping Survey Instrumentation", WCAP-14496 (Proprietary), November,1995 for Fort St. Vrain, being transmitted by Public Service Company of Colorado letter and Application for Witholding Proprietary Information from Public Disclosure, to the Document Control Desk, Attention Mr. Michael F. Weber. The proprietary information as submitted for use by Public Service Company of Colorado for Fort St. Vrain is

)

expected to be applicable in othec licensee submittals in response to certain NRC l

1844C-BID 4110995

. CAW-95-898 requirements for justification of technical basis documents for piping survey instrumentation.

This information is part of that which will enable Westinghouse to:

(a)

Provide documentation of the methods used to perform radiological surveys of plant system piping.

(b)

Establish applicable calibration methods for piping radiological surveys.

j l

(c)

Establish the use of multiple detector assembly designs for surveying piping (including small bore embedded piping with bends.)

(d)

Establish the design methodology of detectors to perform radiological surveys of small bore embedded piping with bends.

(e)

Assist the customer to obtain NRC acceptance of the methods.

Further this information has substantial commercial value as follows:

(a)

Westinghouse plans to sell the use of similar information to its customers for purposes of performing characterization or final site release surveys of plant system piping (including small bore embedded piping with bends).

(b)

Westinghouse can sell support and defense of the technology to its customers for the purpose of documenting the capabilities.

Public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Westinghouse because it would enhance the ability of competitors to provide similar instrumentation and licensing defense services for commercial power reactors without commensurate expenses. Also, public disclosure of the information would enable others to use the information to meet NRC requirements for licensing documentation without purchasing the right to use the information.

18MC Bl&5:110W5

. CAW-95-898 l

l l

The development of the technology described in part by the information is the result j

of applying the results of many years of experience in an intensive Westinghouse 1

effort and the expenditure of a considerable sum of money.

In order for competitors of Westinghouse to duplicate this information, similar' j

technical programs would have to be performed and a significant manpower effort, having the requisite talent and experience, would have to be expended for developing procedure in methodology for testing and utilization.

Further the deponent sayeth not.

1844C-BLD4:1107)5

ATTACHMENT 6 TO P-95102 COPYRIGHT NOTICE

Copyright Notice The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted j

to make the number of copies of the information contained in these reports which are necessary for its internal use in connection with generie and plant-specific reviews and approsals as well as the issuance, denial, amendment, transfer, renewal, moditication, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.790 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection notwithstanding. With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copies beyond those necessary for its internal use which are necessary in order to have one copy available for public viewing in the I

appropriate docket tiles in the public document room in Washington, DC and in local public document rooms as may be required by NRC regulations if the number of copies submitted is I

insufficient for this purpose. Copies made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.

1 I

i i

I 1

l l

\\

ATTACHMENT 7 TO P-95102 PROPRIETARY INFORMATION NOTICE i

l i

Proprietary information Notice Transmitted herewith are proprietary and/or non-proprietary versions of documents furnished to the i

NRC in connection with requests for generie and/or plant-specific review and approvat.

In order to conform to the requirements of 10 CFR 2.790 of the Commission's regulations concerning the protection of proprietary information so submitted to the NRC, the information which is proprietary in the proprietary versions is contained within brackets, and where the proprietary information has been deleted in the non-proprietary versions, only the brackets remain (the information that was contained within the brackets in the proprietary versions having been deleted).

The justification for claiming the information so designated as proprietary is indicated in both versions by means of lower er.se letters (a) through (t) contained within parentheses located as a superscript immediately following the brackets enclosing each item of information being identified as proprietary or in the margin opposite such information. These lower case letters refer to the types of information Westinghouse customarily holds in confidence identitled in Sections (4)(ii)(a) through (4)(ii)(f) of the aftidavit accompanying this transmittal pursuant to 10 CFR 2.790(b)(1).

l 1

1 l

1 f