.l GE NERAL OF FICE gn; P,0 DOX 499, COLUMBUS. NEDRASKA G8602@99 Nebraska Public Power District
- "T&"sF%'n'"
- a
-.n.
.._-gmm,
-..gaw
=____.
NSD920254 -
March 10, 1992
.U. S.-Nuclear Regulatory Commission Doewnent Control Desk Vashington, DC 20555
Subject:
Reactor Containment Building Integrated 1.eak Rate Test Cooper Nuclear Station NRC Docket No.
50 29P, DPR-46 Centlemen:
Pursuant to Appendix J of 10 CFR Part -50, the re.sults of the " Reactor Containment Building Integrated Leak Rate Test" _ conducted December 8-10, 1991, at Cooper Nuclear Station are submitted herewith.
Should you have any questions or require additional information, please contact me,.
Sine ely, b0~~--
Ilo rn -
Nu ar Power Group Manager GRH/dnm:
Enclosure:
.cc:
-Regional Administrator NRC Region IV'-
Arlington, TX NRC Resident inspector Cooper Nuclear Station I
D L\\ \\
9203170257 920310 l
PDR ADOCK 05000298 p-
~PDR owerktf9Hde in Ne asks '~ w a ~
^
"r
^
g=mm==
==mmm.m=mmmme.m m
._=
= _ _ _ _ _ = = _
...m_....-
REACTOR CONTAINMENT llUILDING INTEGRATED LEAK RATE TEST NEBRASKA PUllLIC POWER DISTRICT COOPER NUCLEAR STATION DECEMBER 8-10,1991 DOCKET NO. 50-298 OPERATING LICENSE NO. DPR-46 7
9 i
e
(:
l-
a m,u o
TABLE OF CONTENTS i
TITLE PAGE TABLE OF CONTENTS 11 LIST OF ATTACHMENTS iii
1.0 INTRODUCTION
1 2.0 PREREQUISITES 1
- 3.0 INSTRUMENTATION 1
3.1 Pressure 1
3.2 Dewpoint Temperature 1
- 3.3 Drybulb Temperature 1
3.4 Flow Rate 2
3.5
-Data Acquisition 2
4.0 TEMPERATURE STABILIZATION 2
5.0 TYPE A TEST 3
6.0 VERIFICATION TEST 3
7.0 -
TEST
SUMMARY
3 kgm iA 8.0 '
LOCAL LEAK RATE TEST DATA 4
9.0 BACKUP DATA 4
10.0 EDITED LOG OF EVENTS 5
ii
.. - ~
LIST OF ATTACilMENTS r
i ATTACllMENT TITLE 1
TECllNICAL DATA
SUMMARY
2 INSTRUMENT SELECrlON GUIDE j
3 INSTRUMENTATION 3A Instrumentation List 3B Pressure and Flow Instrumentation 3C Dewcell Imations 3D RTD Locations 4
TEMPERATURE STABILIZATION 4A-Temperature Stabilization Report 4B Graph - Average Temperature 4C Environment Listing 4D Sensor List
-5 TYPE A TEST 5A-Total Time Report 5B Graph - Total Time 5C Mass Point Report
.5D Graph - Mass Point SE Mass Loss Report 5F Graph - Mass Loss 4
SG Graph - Pressure 5H Graph - Average Temperature 51 Graph - Vapor Pmssum :
SJ Environment Listing 5K Sensor List 4
(
,s iii s.
a e
=
b LIST OF ATTACllMENTS ATTACHMENT TrrLE 6-VERIFICATION TEST 6A Total Time Report 6B Graph - Total Time 6C Mass Point Report 6D Graph - Mass Point
-l 6E Mass less Report 6F Graph - Mass Loss 6G Graph - Pressure 611 Graph - Average Temperature 61 Graph - Vapor Pressure 6J Envimnment Listing 6K Sensor List 7-TEST RESULTS 7A Type A Test 7B.
_ Verification Test 8
LOCAL LEAK RATE TEST DATA 8A 1989 - 1991 LLRT Data 8B 1991 LLRT Adjustments for ILRT t
iV
. ~ _ _
1.0 INTRODUCr10N A Primary Containment Integmted 1.cak Rate Test was conducted at Cool,:r Nuclear Station December 8 10, 1991 per CNS Technical Specification 4.7A, CNS Surveillance Pzucedure 6.3.1.3, and 10CFR Part 50, Appendix J, His repon contains a description and analysis of the test as required by 10CFR -
Part 50, Appendix J. Paragraph V.B. The test Technical Data Summary is listed on Attachment 1, 2.0 PREREQUIStrFS All instrumentation used for the Cooper K.tclear Station ILRT met the instrument selection guide (see Attachment 2), and the six month calibration and loop check requirements of ANSI N45.4 - 1972 and ANSI /ANS 56.8 - 1987.
The drywell and suppression chamber were inspected to uncover any structural
' deterioration that could affect the containment integrity or leak tightness. No structural discrepancies were noted. The valve lineups were performed and independently verified, the twelve suppression chamber to drywell vacuum breakers were blocked open to allow pressurization of the torus and two oil-free air compressen with a capacity of 2400 scfm were connected to the air cryer skid and prepared for operation.
3.0 INSTRUMENTATION The following instrumentation was used in the performance of the 1991 Cooper Nuclear Station Integrated Leak Rate Test.
3.1 Pressure Two (2) precision pressure gauges with vibrating stainless steel cylinder type sensors monitored containment pressure. The average of the two readings was utilized in the leakage rate calculations.
3.2' Dewpoint Temperature Six (6) chilled mirror dewpoint hygrometers were installed to measure the containment dewpoint temperature.
3.3 Drybulb Temperature Containment drybulb temperature was monitored by twenty-six (26) platinum Resistance Temperat: re Detectors (RTDs).
1
3.4 Flow Itate The Dow rate of the superimposed leak required for the veriReation test was measured by a thermal mass Dowmeter.
3.5 Data Acquisition The CNS Plant Management Information System (PMIS) was utilized to collect data from all sensors. A personal computer received the data from the PMIS and performed the necessary calculations.
Instrument weighing factors and locations are listed on attachment 3A.
Pressure and flow instrumentation are shown on Attachment 311.
Pressure and Deweell and IRTD locations are illustrated on Attachments 3C and 3D respectively.
4.0 TEMPEllATUltE STAlllLIZATION The temperature stabilization period began at 14:00 on December 9,1991. The criteria for temperature stabilization were:
1)
The latest rate of change of the weighted average containment air temperature, averaged over the last hour, does not deviate by more than 0.5'F/ hour from the average rate of change of the weighted average contained air temperature over the last four hours (ANSI /ANS 56.8-1987).
2):
. The rate of change of average temperature is less than 1*F/ hour averaged over the last two hours (llechtel Topical Iteport ilN-TOP 1).
3)
The. rate of change of temperature changes less than 0.5'F/ hour averaged over the last two hours, All of the above criteria were met at 18:00 on December 9,1991. Supporting graphs and listings are contained in Attachment 4.
L 2
I'
5.0 TYPE A TEST The Type A Test started at 20:15 on December 9,1991. Containment pressure, weighted average temperature and weighted average dewpoint temperature were recorded at appmximately fifteen minute intervals. The total time leakage rate was calculated per Bechtel Topical Report BN-TOP-1, Section 6.0. The mass point calculations were based on ANSI /ANS 56.8-1987, Section 5.7.
The Type A Test was concluded after 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> at 04:15 on December 10,1991. contains supporting graphs and listings pertaining to the Type A Test.
6.0 VERIFICATION TEST Immediately following the Type A Test, a metering valve was adjusted on flowmeter FR2 to a flow rate of approximately 5.14 scfm. The Verification Test began at 05:30 on December 10,1991. Containment pressure, weighted average temperature, and weighted average dewpoint temperature were again recorded at appmximately fifteen minute intervals. The total time and mass point leak rate analysis techniques were again employed.
The Verification Test ended at 09:30 on December 10, 1991. Graphs and listin.3 related to the Verification Test are contained in Attachment 6.
7.0 TEST
SUMMARY
Pressurization for the ILRT began at 17:30 on December 8,1991, at a rate of approximately 7.0 psi per hour. - At 01:13 on December 9,1991, a leak was discovered on the drywell vent monitor. The leak was quantified at 3.2 scfm using an electronic mass flow meter and the vent monitor was isolated. The pressurization equipment was secured at 02:05 on December 9,1991 with a peak instantaneous pressure of 72.876 psia.
The temperature stabilization period began at 14:00, the test criteria were satisfied at 18:00 and the Type A Test began at 20:15 on December 9,1991.
Temperature, dewpoint temperature, and pressure data were recorded at approximately fifteen minute intervals during the test.
The Type A Test was completed at 04:15 on December 10,1991, with a Total Time Upper Confidence Level leak rate of.19507% wt/ day and a Mass Point Upper Confidence leak rate of.18013% wt/ day. See Attachment 7A for complete test results.
3
A superimposed leak of appmximately 5.14 scfm was metered through a mass flowmeter and'the verification test began at 05:30 on _ December 10, 1991.
Acceptability-of the 'ILRT was; demonstrated (see Attachment 7B) and the verification test was completed at 09:30. Depressurization of the primary _
containment began at 11:10 and was completed at 20:15.
The Cooper Nuclear Station Primary Containment Integrated Leak Rate Test was successfully completed demonstrating the leak-tight _ integrity of the reactor -
primary containment and~ the systems and components which penetrate the primary containment.
8.0 -
LOCAL LEAK RATE TEST DATA The 1989,1990, and 1991 local leak rate test results aflect the total leakage as determined by testing between containment isolation valves. In 1991, the individual leakage from the inboard and outboard valves of each penetration
- which requimd cornetive or preventive maintenance was also quantified. The
' diffemnce was reported in addition to the Type A leakage. This was done in order to reconstruct the "as found" condition of the primary containment befom repairs were made.
' A summary of the local leak rate test data from 1989,1990 and 1991 can be L
found in Attaclunent 8A. 'Ihe data includes the as found leakage rates and the as left leakage rates. The leakage adjustments to the 1991 ILRT are listed on -
1 Attaciunent 8B.
9.0 BACKUP DATA The backup data retained at Cooper Nuclear Station includes the following:
Integrated Leak' Rate Test Procedure 6.3.1.3 -
Local Leak Rate Test Procedme 6.3.1.1 System' Piping and Instrumentation Diagram-Test Instrument Calibration Data Computer Program Verification and Validation Containment Penetration Listing System Status (at'the time of the test)
Test Director's Log -
e' Instrument Weighing Factor Data i
4 l
L
l l
10.0 EDITED LOG OF EVENTS DECEMBER 8,1991 1430
- Completed Drywell and Torus Inspection 1730-Started Pressurization of Containment DECEMBER 9,1991 0035 Drywell vent monitor particulate detector found blown out, leakt.ge quantified at 3.2 scfm 0205 Isolated ILRT gate valve at test pressure 0930 Valves PC-AOV-243AV,-244 AV, and PC-MOV-233MV had leaks at the valve shaft. These leaks were not repairable nor was there any acceptabic method to quantify the leaks. leakage.was observed out of the exhaust port of NM-SOV-SV1. The manual valve was isolated. The leak was later determined to be from check valve NM-CV-1CV, was quantified at 0.24 SCFM, and was isolated. 'Ihe check valve was replaced by MWR 91-4035. The new installation LLRT yielded at leakage of 0.37 SCFH.
1315-Repressurized containment to 58.50psig as single burp 1400 Temperature Stabilization period begun 1800 Temperature Stabilization criteria met 2015 Type A Test started DECEMBER 10,1991 0415 Type A Test complete 0430 Commenced I hour Stabilization for Verification Test using FR2 at 5.14scfm -
0530 Started Verification Test 0930 Ended Verification Test 1110 Started Depressurization 2015 Depressurization complete 2325 Completed post ILRT containment inspection 5
Attichment 1 2
COOPER NUCLEAR STATION
-1991 ILRT TECllNICAL DATA
SUMMARY
- A.
GENERAL DATA '
Owner: -
Nebraska Public Power District Docket No.:
50-298
- Location:
Brownville, Nebraska Containment
Description:
BWR 4, Mark I Date Test Completed:
December 10,1991
- B.
TECIINICAL-DATA' n
Containment Free Volume:
242,550 cu. ft.-
- Design Pressure:
56.0 psig Design Temperature:
281 F Calculated Accident Peak Pressure:
46.2 psig Calculated Accident. Peak Temperature:
293*F C..
TEST DATA-Test Method:
Absolute Data Analysis _ Technique:
Total Time / Mass Point Test Pressure:
~ Start:
72.263 psia End:
72.231 psia Maximum Allowable Leak Rate (L,):.
.635 %/24 hr.-
' Calculated Leakage UCL:
Total Time:
.19507 %/24 hr.
Mass Point:
.18013 %f24 hr.
Measured Leakage (L,,)
Total Time:
.17103'%/24 hr.-
Mass Point:
.17768 %/24 hr.
. D.-
- VERIFICATION Calibrated Leak Superimposed N):
.636 %/24 hr.-
Composite I.eakage A):
Total Time:.7408 %/24 hr.
Mass Point:
.7353 %/24 hr.
Page 1 of 1-u,
INSTRUMENT SELECTION GUIDE instrument selection guide ISG leakage mte, percent per day L
test duration, hours t
containment atmosphere total absolute pressure P
containment atmosphere panial pressum of water vapor Pv containment atmosphere weighted average absolute drybulb temperature T
error associated with measurement of change in a given parameter c-error associated with sensor (sensitivity)
E error associated.with measumment system (excluding sensor) e A.
TEST PARAMETERS L.
.635 %/ day 72.231 psia P
539.569 R drybulb T
.73.195 F dewpoint
. T, 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> t-B.
INSTRUMENT PARAMETERS
-L Total absolute pressure error ('P)
No. of sensors:
2 Range:
0-100 psia Pressum sensor sensitivity error (EP):
.005 psia Pressum measurement system error ('P):
.00076 psia if('P)2, (.p)2 ) in / [no, of sensors] '"
'P
=
1[(.005)2 + (.00076)'] '" / [2]'"
'P
=
=
.0050574 / 1.4142136
'P 0035761 psia
'P
=
Page 1 of 3
- 2,
r
.....,~
2.
Water vapor pressure error ('Pv)
Dewcells No. of sensors:
6 Range:
40-100 F Vapor pressure sensor sensitivity error ('Pv)
.54 F (.0074142 psia)*
Vapor pressure measurement system ermr ('Pv):
.027% fs (.00037071 psia)*
1[(Epy)2 4 [epy)2jtn / (no of sensors]'#
'Pv
=-
1[(.0074142)2 + (.00037071)2 '" / [6]'"
1
'Pv
=
2 0074235 / 2.44949
'Pv
=
.0030306 psia
'Pv
=-
The equivalent water vapor change between 73 F and 74 F is.01373 psia / F. (from Steam Tables) 3.
Temperature error ("Il No. of sensors:
26 Range:
0-200 F Temperature sensor sensitivity error (*1'):
.09 F Temperature measurement system error ("T):
.0323'F fl("T)* + CT)]'d / [no, sensors]'"
'T
=-
3I(.09)2 + (.0323)2) in / [26]'8
'T
=
.09562 / 5.0990195-
'T
=
'T
_.018753'R
=
Page 2 of 3
<~-
4.
ISG =1(2400/t) [2('P/P)'+ 2('Pv/P)2+ 2("r/r)2)in ISO =1(2400/8) [2(.0035761/12.231)2+ 2(.0030306/12.231)2+
2(.018753/539.569)']'"
ISG = i300 [4.9E-09 + 3.5208E4) + 2.416E-09]'"
ISG = 0.03123%/ day The ISG formula does not exceed 0.2512 (0.15875%/ day) and it is therefore concluded that the instrumentation selected was acceptable for use in determining the reactor containment integrated leakage rate.
Page 3 of 3
. A INSTRUMENTATION LIST No. - Descript!on Location Elev.
Azim.
W1.
-DC1 Dewpoint Drywell West 901' O
.1500 DC2' Dewpoint Drywell Southwest 901' 240
.1500
- DC3 Dewpoint' Drywell West 962' O
.1500 DC4 Dcwpoint
. Drywell Nonhwest 901*
120
.1000 DC5 Dewpoint Torus East 876' 180
.2250 DC6 Dewpoint Torus West 876' 0
.2250
.DC7 Dewpoint Toms East RTD 876' 180
.0000 DC8 Dewpoint Toms West RTD 876' 0
0000 T1 Temperature Drywell South 901' 270
.0285 T2 Temperature Drywell Nonhwest 901' 60
.0257 T3 Temperature Drywell orth 901' 90
.0228 N
T4 Temperature Drywell Southeast 901' 220
.0513 T5 Temperature Drywell South 901' 270
.0285 T6 Temperatme Drywell Northwest 901' 60
.0256 T7 Temperature Drywell Nonh -
901' 90
.0227 T8 Temperature
- Drywell Southwest 888' 300
.0375 T9 Temperature Drywell Southwest 888' 300
.0375 T10 Temperature Drywell Northeast 888' 120
.0375 Til - Temperature Drywell Northeast 888' 120
.0375 T12 Temperature :
Drywell West 933' 0
.0349 T13 Temperature Drywell Northeast 933' 145
.0282 T14 Temperature
_ Drywell Southeast 933' 225
.0266 T15 Temperature Drywell West 974' O
.0173 T16 Temperature Drywell Northwest 974' 70
.0113 T17 - Temperature
- Drywell_ Nonheast _
974' 140
.0125 T18 Temperature
- Drywell Southeast 974' 220
.0185 T19 Temperature _
Drywell West
'978' 15
'.0204
'T20 Temperature Drywell Southeast 978' 255
.0204 T21-Temperature Tonis West 876' 0
.0758 T22 Temperature Torus Nonhwest 876' 60
.0758
'T23 Temperarme Torus Nonheast.
876' 120
.0758 T24 Temperature Torus East.
876' I80
.0758 T25 Temperature
- Torus Soutuast
-876' 240
.0758 T26' Temperature Torus Southwest 876' 300
.0758 P1 Pressure 1 Reactor Bldg. SE 931' N/A
.5000 P2!
Pressure 2 -
Reactor Bldg. SE 931' N/A
.5000 FR1 Flow Raz 1 Reactor Bldg. SE 931' N/A
.0000 FR2 Flow Rate 2 Reactor Bldg. SE 931' N/A 1.00(X)
Page 1 of 1
.x.
AI Isolation
/
)
110V Power Supply Ta.sformer P1 u
(
)
Volumetrics
. M-1000 Pressme Ganges y;
o100 PSIG Q
l g
(
3
'gF P2 s
mm pyc
's g
TUBNG
(
j
-+.
w vee Q
W)
M
%.)
,,7%e.
- y E
%PC100
- y, o
ep } Pc l
W FRI
- e~
[4 f
x o,
$~
~Sl
- ' O' I
Y Y
i a,
numetncs g4$
==
m wers i
0-10 SCFM r
M t
25-6 Rack W
FR2 R.931-SE J
PC 11111111-puis Cabinet 9-Si Link 4 PRESSURE AND FLOW l
n-903-se INSTRUMENTATION SCHEMATIC i
a
>1 a5 T
R.
I I
R E
PO O
N C
O ITAC O
L m
4, L
=-
L EC W
ED I5 i
I l:l i
i:
iiI I:
i 1
>l9 0
r R
I I
R E
P OOC SN O
IT A
n.
C h.
. i O
^
L D
- s-
- 3 1il ll.!
lll:l
Attaciunent 4A e,"*******************
TEMPERATURE STABILIZATION DATE 13-1991 TIMT. - 09:22:56 TIME TEMP TEMP DN-TOP-1 DN-TOP-1 TEMP ANSI (DELTA)
DIFF AVG AVG RATE AVG CRIT (HOURS) TEMP.
INCR (1 HR)
(2 HR)
(2 IIR)
(4 HR) 0.00-539.842 0.000 0.000 0.000 0.000 0.000 0.000 0.25 539.848 0.006 0.000 0.000 0.000 0.000 0.000 0.50 539.860 0.012 0.000 0.000 0.000 0.000 0.000 0.75 539.859
-0.001 0.000 0.000 0.000 0.000 0.000 1.00 539.844
-0.015 539.843 0.000 0.000 0.000 0.000 1.25 539.809
-0.036
( 19.828 0.000 0.000 0.000 0.000 1.50 539.752
-0.056
!39.806 0.000 0.000 0.000 0.000 1.75 539.703
-0.049 s39.781 0.000 0.000 0.000 0 000 2.00 539.666
-0.037 539.755
-0.088 0.091 0.000 0.000 2.25 539.627
-0.039 539.718
-0.111 0.111 0.000' O.000 2.50 539.591
-0.035 539.672
-0.134 0.134 0.000 0.000 2.75 539.564
-0.027 539.634
-0.147 0.147 0.000 0.000 3.00 539.546
-0.019 539.606
-0.149 0.149 0.000 0.000 3.25 539.531
-0.015 539.579
-0.139 0.139 0.000 0.000 3.50 539.517
.-0.014 539.554
-0.118 0.118 0.000 0.000 3.75 539.510
-0.007 539.537
-0.097' O.097 0.000 0.000
-4.00 539.501
-0.008 539.524
-0.082 0.082
-0.085 0.041 4.25 539.497
-0.004 539.514
-0.065 0.065
-0.088 0.054 4.50 539.485
-0.012 539.501
-0.053 0.053
-0.094 0.061 4.75 539.483
-0.002 539.496
-0.041 0.041
-0.094 0.067 5.00 539.473
-0.009 539.487
-0.036 0.036
-0.093 0.065 5.25 539.480 0.006 539.488
-0.026 0.026
-0.082 0.065 5.50 539.474
-0.006
-539.479
-0.022 0.022
-0.070 0.059 5.75 539.472
-0.002 539.477.
-0.019 0.019
-0.058 0.047 6.00 539.466
-0.006 539.470
-0.018 0.018
-0.050 0.043 6.25 539.470 0.004 539.475
-0.013 0.013
-0.039 0.030 6.50 539.473 0.003 539.473
-0.006-0.006
-0.030 0.029 l
l Page 1 of 1 i
?
AVERAGE TEMPERATURE - TEMPERATURE STABILIZ.ATION COOPER - DECEMBER 9.1991 80.258 80.200 N
s 80.150 \\
80.100 D
\\
E 88.850
\\
g
\\
R 88.800
\\.
E s
E 79.950 N
S N
79,900 s
' N ~'
p 79.850
~_
m
%~
79.800 t
0.00 0.65 1.38 1.95 2.60 3.25 3.98 4.55 5.20 5.85 6.58 (13:30)
(14:48)
(16: 6)
(17:24)
(19:42)
(20: 8)
E 13:38: 0 DELTA TIME IN HOURS REC.82 - 108
.m
.m
. C EtNIRONMENT LISTING DATE - 11.13-1991 TIME - 09:23:00 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE A7R PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE E
82 9 1330 539.842
=0.3896 72.4334 76.39 0.3622 0.00000 83 9 1345 539.848 0.3891 72.4339 76.27 0.3622 0.00192 84 9 1400 539.860 0.3906 72.4269 76.54 0.3621
-0.02811 85 9 1415 539.859 0.3903 72.4182 76.49 0.3621
-0.03482 86 9 1430 539.844 0.3913 72.4052 76.72 0.3620
-0.05194 87 9 1445 539.809 0.3911 72.3904 76.77 0.3620
-0.05930 88 9 1500 539.752 0.3911 72.3774 76.91 0.3619
-0.05194 89 9 1515 539.703 0.3917 72.3618 77.15 0.3619
-0.06229 90 9 1530 539.666 0.3924 72.3511 77.3D 0.3619
-0.04291 91 9 1545 539.627 0.3923
-72.3512 77.46 0.3619 0.00049 92 9 1600 539.591 0.3933 72.3427 77.75 0.3619
-0.03403 93 9 1615 539.564 0.3937 72.3368 77.90 0.3619
-0.02368 94 9 1630 539.546 0.3931 72.3324 77.82 0.3619
-0.01749 95 9 1645 539.531 0.3938 72.3272 77.99 0.3618
-0.02063 96 9 1700 539.517 0.3940 72.3235 78.07 0.3618
-l.01489 97 9 1715 539.010 0.3938 72.3197 78.04 0.3618
-0.01511 98-9 1730-539.501 0.3943 72.3162 78.17 0.3618
-0.0140" 99 9 1745 539.497 0.3946 72.3129 78.25 0.3618
-0.01340 100 9 1800 539.485 0.3948 72.3096 78.32-0.3618
-0.01294 101 9 1815 539.483 0.3950 72.3065 78.36 0.3618
-0.01260 102 9 1830 539.473 0.3951 72.3039 78.41 0.3618
-0.01044 103 9 1845 539.480 0.3950 72.3015 78.37 0.3617
-0.00958 104 9 1900 539.474 0.3950 72.2985 78.37 0.3617
-0.01184 105 9 1915 539.472 0.3956 72.2889 78.51 0.3617
-0.03860 106 9 1930 539.466 0.3964 72.2796 78.69 0.3616
-0.03729 107 9 1945 539.470 0.3966 72.2714 78.70 0.3616
-0.03250 108 9 2000 539.473 0.3959 72.2641 78.57 0.3616
-0.02939 Page 1 of 3
Attaclunent 4C 1
ENVIRONMENT LISTING 1
DATE 13-1991 ZONE -
1 TIME - 09:23:02 l REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE
. AIR PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE
.a.
82 9 1330 542.693 0.3457 72.4753 61.82 0.3605 0.00000 83 9 1345 542.820 0.3451 72.4759 61.46 0.3604 0.00253 84 9 1400 542.905 0.3480 72.4680 61.01 0.3603
-0.03100 85 9 1415 542.939 0.3479 72.4591 61.71 0.3602
-0.03534 86 9 1430 542.942 0.3496 72.4454 62.01 0.3602
-0.05487 87 9 1445 542.892 0.3496 72.4304 62.12 0.3601
-0.06015 88.
9 1530 542.815 0.3498 72.4172 62.30 0.3601
-0.05258 89 9 1515 542.742 0.3506 72.4014 62.59 0.3601
-0.06311
.90-9 1530 542.680 0.3518 72.3902 62.93 0.3601
-0.04504 91 9 1545 542.625 0.3518 72.3902 63.04 0.3601 0.00015 92 9 1600 542.564 0.3535 72.3805 63.47 0.3601
-0.03888 93
-9 1615 542.530 0.3541 72.3748 63.66 0.3601
-0.02261 94 9 1630 542.510 0.3535 72.3705 63.59 0.3601
-0.01755 95 9 1645 542.492 0.3546 72.3644 63.82 0.3600
-0.02435 96 9 1700 542.473 0.3549 72.3611 63.92
-0.3500
-0.01328 97-9 1715 542.463 0.3548 72.3572 63.91 0.3600 -0.01544 98
.9 1730 542.471 0.3556 72.3534 64.05 0.3600 -0.01535 99 9 1745 542.460 0.3561 72.3499 64.15 0.3600 -0.01376 100 9 1800 542.453 0.3566 72.3464 64.26 0.3600 -0.01413 101-
'9 1815 542.457 0.3571 72.3429 64.33-0.3600 -0.01376 102 9 1830 542.449 0.3575 72.3395 64.43 0.3600
-0.01379 103 9 1845 542.461 0.3575 72.3375 64.41 0.3599
-0.00800 104 9 1900 542.460 0.3572 72.3348 64.35 0.3599
-0.01077 105 9'1915 542.466 0.3586-72.3244 64.58 0.3599
-0.04144 106 9 1930 542.469 0.3600 72.3140 64.84 0.3598
-0.04181 107 9 1945 542.486 0.3605 72.3055 64.89 0.3598
-0.03394 108 9 2000 542.487 0.3593 72.2987 (4.67 0.3597
-0.02722 Page 2 of 3 i
- 0 ENVIRONMENT LISTING
.DATE 13-1991 ZONE -
2 TIME - 09:23:04 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE B2 9-1330 536.424 0.4496 72.3754 98.60 0.3642 0.00000 83-9 1345 536.285 0.4494 72.3756 98.99 0.3643 0.00101 84 9 1400 536.210 0.4487 72.3703 99.10 0.3643
-0.02136 85 9 1415 536.167 0.4402 72.3618 95.13 0.3643
-0.03406 86
'9 1430
-536.131 0.4480 72.3300 99.21 0.3642
-0.04733 87-9 1445 536.112 0.4476 72.3354 99.16 0.3642
-0.05804 88 9 1500 536.080 0.4473 72.3227 99.21 0.3641
-0.05103 89 9 1515 536.060 0.4476 72.3074 99.33 0.3641
-0.06097 90 9-1530
-536.052 0.4475 72.297b 99.34 0.3640 -0.03964 91 9 1545 536.033 0.4472 72.2978 99.35 0.3641 0.00098 92' 9 1600-536.029 0.4471 72.29"9 99.35 0.3640 -0.02768 93 9 1615' 536.009 0.4472 72.26.c 99.43 0.3640
-0.02432 94 9 1630 535.993~
0.4466 72.2864 99.34' O.3640 -0.01740 95 9:1645 535.981.
0.4466.
72.2764 99.37 0.3640
-0.01599 "96 9:1700 535.973 0.4467 72.2723 99.42 0.3640 -0.01633 97 9 1715 535.969 0.4463 72.2687 99.36 0.3639
-0.01471 98 9 1730 535.942 0.4463 72.2657 99.45 0.3640 -0.01199 99
- 9 1745 535.946 0.4466 72.2624 99.49 0.3639
-0.01297 100 9 1800 535.926 0.4463 72.2597 99.50 0.3639
-0.01102 101 9 1815 535.918 0.4461 72.2569 99.47 0.3639
-0.01102 102 9 1830 535.906-0.4457 72.2553 99.42 0.3639
-0.00638 103 9 1845 535.906 0.4454 72.2526 99.37 0.3639
-0.01102 104 9 1900-535.894 0.4458 72.2492 99.48 0.3639
-0.01331 105 9 1915 535.882 0.4453 72.240:
99.43 0.3639
-0.03436
'106 9 1930 535.867.
O.4453 72.2327 99.46 0.3638
-0.03168 107-9 1945 535.855 0.4449 72.2231 99.41 0.3638
-0.03036 108 9 2000 535.859 0.4450 72.2170 99.43 0.3638
-0.03265 l~
L l
Page 3 of 3 L
. D SENSOR LIST RECORD NUMBER - 82 DATE - 12/ 9 TIME - 13:30: O PRESSURES 72.82500 72.82100 2_
1 0.00000 0.00000 INACT INACT 0.00000 0.00000-INACT INACT AVG PRESSURE 72.82300 RTD/S 1
81.647 2
84.613 3
83.023 4
78.658
'S 80.318 6
81.362 7
80.935 8
79.109 9
79.132 10 79.227 11 79.156 12 85.798 13 85.292 14 85.141 15 92.310 16 92.191 17 91.929 18 93.260 19 87.605 it0 87.605 21 75.174 22 76.809 23 77.164 24 76.738 25-76.548.
26
-78.089 INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 INACT 50.254 INACT 0.033 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
'O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 80.172 DEW CELLS 1
67.361 2
68.734 3
69.752 4
68.081 5
76.614 6
76.038 INACT 76.738 INACT 75.174 INACT-0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG' DEW CELL 72.032 14.43219-AMBIENT PRESS VAPOR PRESS
- =.3895716 72.43343 DRY PRESSURE FLOWS
.3009 0
TOTAL FLOW 0
Page 1 of 27
o J
Attcchment -4D SENSOR LIST RECORD NUMBER -
83 DATE - 12/ 9 TIME - 13:45: O PRESSURES-72.82500 72.82100 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.82300
-RTD/S 1
81.694 2
84.922 3
83.142 4
78.682 5
80.271 6
81.410 7
80.911 8
79.038 9
79.038 10 79.132 11 79.061 12 86.014 13 85.765 14 85.655 15 92.642 16 92.666 17 92.452 18 93.760 29 87.843 20 87.795 21 75.055 22 76.690 23 77.022 24 76.596 25 76.406 26 77.923 INACT 0.000 INACT 0.000 INACT O.000 It\\CT 0.000 INACT 49.033 INACT 0.033 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000-INACT 0.000 INACT
-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 AVG RTD 80.178 DEW CELLS 1
67.505 2
68.280 3
69.719 4
68.302 5
76.581 6
76.038 INACT 76.596 INACT 75.055 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 AVG DEW CELL 71.995 AMBIENT PRESS
- 14.43219
.3890888 VAPOR PRESS 72.43391 DRY PRESSURE
.2498 0
FLOWS TOTAL FLOW 0
Page 2 of 27
. D SENSOR LIST RECORD NUMBER -
84-DATE - 12/ 9 TIME - 14: 0: 0 PRESSURES 72.81900 72.81600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.81750 i
RTD/S 1
81.694 2
85.041 3
83.189 4
78.682 5
80.271 6
81.457 7
80.911 8
78.990 9
'79.038 10 79.085 11 79.061 12 86.014 13 86 023 14 86.040 15 93.046 16 92.975' 17
-92.761-18 93.997 19 88.033 20 88.009 21 74.984 22 76.572 23 76.951 24 76.548 25 76.311 26 77.876 INACT 0.000 INACT 0.000 INACT
-0.000
-INACT 0.000 INACT 47.910 INACT O.033 INACT.
0.000 INACT 0.000 INACT 0.000 INACT 0.000
,INACT.
0.000 INACT 0.000-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000-INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 80.190 DEW CELLS 1
67.915 2
68.678 3
69.763 4
68.391 5
76.581 6
75.950 INACT 76.548 INACT 74.984
- INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT
-0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.112
. AMBIENT PRESS - 14.4319
.3906228
' VAPOR PRESS 72.42688
' DRY PRESSURE
.2877-0 FLOWS TOTAL FLOW O
Page 3 of 27
. D SENScR LIST RECORD NUMBER -
85 DATE - 12/ 9 TIME - 14:15: O PRESSURES 72.81000 72.80700 2
1 0.00000 0,00000 INACT INACT 0.00000 0.00000 IllACT INACT AVG PRESSURE 72.80850 RTD/S 1
81.718 2
85.064 3
83.237 4
78.650 5
80.271 6
81.481 7
80.911 8
78.943 9
79.038 10 79.005 11 79.061 12 86.143 j
13 86.152 14 86.003 15 93.379 16 92.951 17 92.714 la 93.902 19 88.199 20 80.151 21 74.937 22-76 148 23 76.927 24 76.453 25 76.264 26 77.852 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 46.963 INACT 0.033 INACT 0.000
.INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000
-INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 IldACT 0.000 AVO RTD 80.189 DEW CELLS 1
60.081 2
68.468 3
69.741 4
68.413 5
76.548 6
75.917 INACT 76.453 INACT 74.937 INACT 0 000 INACT 0.000 INACT 0.000 INACT O.000 INACT
-0.000 INACT 0.000 INACT 0.000 AVG DEW CELL
.089 14.43155 AMBIENT PRESS
.3903244 VAPOR PRESS 72.41817 DRY PRESSURE
.2251 0
FLOWS TOTAL FLOW 0
Page 4 of 27
Attaclunent 4D SENSON LIsr RECORD NUMBER -
86 DATE - 12/ 9 TIME - 14:30: 0 f
PRESSURES 72.79800 72.79500 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVO PRESLURE 72.79649 RTD/S 1
81.718 2
85.064 3
83.237 4
78.682 5
80.247 6
81.528 7
80.935 8
78.943 9
79.038 10 79.061 11 79.038 12 86.402 13 86.195 14 86.083 15 93.213 16 92.690 17 92.452 18 93.688 19 88.294 20 88.246 21 74.913 22 76.524 23 76.880 24
'76.430 25 76.240-
-26 77.781 IhACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.338 INACT 0.033
~
INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 l
AVG RTD 80.174 DEW CELLS 1
68.191 2
68.723 3
69.829 4
68.523 4
5 76.525 6
75.917 INACT 76.430 INACT 74.913 1NACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 1NACT 0.000 INACT 0.000 INACT 0.000 l
AVG DEW CELL 72.163 14.43155 AMBIENT PRESS
.3913007 VAPOR PRESS 72.40519 DRY PRESSURE
.1543 0
FLOWS TOTAL FLOW 0
i Page 5 of 27
Attadunent 4D sensor LIST RECORD UUMBER -
87 DATE - 12/ 9 TIME - 14:45: O PRESSURES 72.78300 72.78000 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.78149 RTL5/S 1
81.718 2
85.017 3
85.237 4
78.682 5
80.271 6
81.528 7
80.911 8
78.943 9
79.014 10 79.061 11 79.061 12 86.316 13 86.152 14 85.997 15
't.690 16 92.452 17 92.143 18 93.403 19 88.341 20 88.270 21 74.889 22 76.524 23 76.856 24 76.406 25 76.216 26 77.757 INACT 0.000 1NACT 0.000 INACT 0.000 INACT 0.000 INACT 45.695 INACT 0.033 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.090 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.006 INACT 0.000 AVG RTD 80.139 DEW CELLS 1
68.280 2
68.546 3
69.907 4
68.557 5
76.525 6
75.850 INACT 76.406 INACT 74.889 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.150 14.43318 AMBIENT PRFSI
.3911257 VAPOR PRESS 72.39037 DRY PRESSURE
.2449 0
FLOWS TOTAL FLOW 0
t O
Page 6 of 27
i Attechment 4D l
SENSOR LIST RECORD NUMBER - 88 DATE - 12/ 9 TIME - 15: 01 0 PRESSURES 72.77000 72.76700 2
1 0.00000 0.00630 INACT INACT 0.00000 0.0000' INACT INACT AVG PRES $URE 72.76..y RTD,
1 81.742 2
84.946 3
83.213 4
70.682 5
60.295 6
81.528 7
00.911 0
78.943 9
79.014 10 79.005 11 79.038 12 83.057 13 86.023 14 85.826 15 92.405 16 92.048 17 91.715 38 92.975 19 88.318 20 88.246 21 74.842 22 76.453 23 76.833 24 76.382 25 76.216 26 77.733 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.605 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.Os )
INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 80.002 DEW CELLS 1
68.457 2
68.291 3
69.984 4
68.623 5
76.503 6
75.839 INACT 76.382 INACT 74.842 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000' INACT 0.000 INACT 0.000 AVG DEW CELL 72.149 14.43318 AMBIENT PRESS
.3911148 VAPOR PRESS 72.37738 DRY PRESSURE
.0984 0
L TLOWS TOTAL FLOW 0
Page 7 of 27
. -. _ D SENSOR LIET RECORD NUMBER - 89 DATE - 12/ 9 TIME - 15:15: O PRESSURE 3 72.75500 72.75200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.75349 s
RTD/S 1
81.742 2
84.874 3
83.142 4
78.682 5
80.295 6
81.576 7
80.911 8
78.919 9
79.014 10 79.061 11 79.014 12 86.057 13 85.851 14 85.740 15 91.953 16 91.644 17 91.287 18 92.571 19 88.246 20 88.175 21 74.818 22 76.430 23 76.809 24 76.382 25 76.169 26 77.733 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.893 INACT 0.033 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 85.s33 DEW CELLS 1
68.490 2
68.435 3
70.062 4
68.001 5
76.514 6
75.861 INACT 76.382 INACT 74.818 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.193 14.43445 AMBIENT PRESS
.3916872 VAPOR PRESS 72.36181 DRY PRESSURE
.2893 0
FLOWS TOTAL FLOW 0
Page 8 of 27
Attadunent 4D SENSOR List PTCOPD NUMDER - 90 D ATE - 12 / 9 TIME - 15:30: O PRESSURES 72.74500 72.74200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.74350 RTD/S 1
81.742 2
84.803 3
83.142 4
78.682 5
80.271 6
81.576 7
80.911 0
78.943 9
79.014 10 79.061 11 79.038 12 85.970
~
13 85.722 14 85.612 15 91.834 16 91.287 17 90.883 18 92.119 19 88.151 20 88.104
~
21 74.818 22 76.453 23 76.785 24 76.358 25 76.145 26 77.733 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.449 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.996 DEW CELLS 1
68.601 2
68.678 3
70.040 4
68.670 5
76.503 6
75.861 INACT 76.358 INACT 74.818 INACT 0.000 INACT 0.000 INACT 0.000 INhCT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.248 14.43530 AMBIENT PRESS
.3924144 VAPOR PRESS 72.35108 DRY PRESSURE 0
0 TLOWS TOTAL FLOW U
Page 9 of 27
. D 1
nENs0R LIST RECORP NUMBER -
91 DATE - 12/ 9 TIME - 15:45: O PRESSURr,s 72.74500 72.74200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.74350 RTD/S 1
81.718 2
84.780 3
83.110 4
78.682 5
80.295 6
81.552 7
80.935 8
78.943 9
79.038 10 79.085 11 79.014 12 85.970 13 85.636 14 85.526 15 91.525 16 90.931 17 90.551 18 91.739 19 88.056 20 87.985 21 74.794 22 76.430 23 76.738 24 76.358 25 76.145 26 77.710 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.979 INACT O.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.957 DEW CELLS 1
68.623 2
68.557 3
70.004 4
68.745 5
76.492 6
75.839 INACT 76.358 INACT 74.794 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.239 14.43539 AMBIENT PRESS
.3922936 VAPOR PRESS 72.3512 DRY PRESSURE 0
0 FLOWS TOTAL FLOW O
Page 10 of 27
Attadmient 4D i
SENSOR LIST RECORD NUMBER -
92 DATE - 12/ 9 TIME - 16: 0: O PRESSURES 72.73000 72.73400 2
1 0.00000
~
0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVO PRESSURE 72.73600 RTD/S 1
81.718 2
84,803 3
83.071 4
70.658 5
80.271 6
81.552 7
80.911 8
78.966 9
79.038 10 79.109 11 79.038 12 85.798 13 85.550 14 85.440 15 91.145 16 90.670 s
17 90.313 18 91.430 19 87.961 20 87.866 21 74.794 22 76.430 23 76.761 24 76.335 25 76.145 26 77.686 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.861 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 IDACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.921 i
DEW CELLS 1
68.656 2
68.911 3
70.184 4
68.800 5
76.492 6
75.828 INACT 76.335 INACT 74.794 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.315 14.43381 AMBIENT PRESS i
.3932998 VAPOR PRESS 72.3427 DRY PRESSURE
.1642 0
FLOWS TOTAL FLOW 0
Page 11 of 27
_ _... D SENSOR LIST RECORD NUMBER -
93 DATE - 12/ 9 TIME - 16:15: O PRESSURES 72.73200 72.72900 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.73050 RTD/S 1
81.718 2
84.803 3
83.094 4
70.682 5
80.271 6
81.552 7
80.935 8
78.919 9
79.038 10 79.065 11 79.038 12 85.798 13 85.507 14 85.398 15 90.931 16 90.456 17 90.123 18 91.216 19 87.890 20 87.795 21 74.771 22 76.406 23 76.738 24 76.335 25 76.121 26 77.662 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.793 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 1NACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.894 DEW CELLS 1
68.745 2
69.021 3
70.150 4
68.844 5
76.470 6
75.861 INACT 76.335 INACT 74.771 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.347 14.43126 AMDIENT PRESS
.3937214 VAPOR PRESS 72.33678 DRY PRESSURE
.2367 0
TLOwS TOTAL FLOW 0
Page 12 of 27
Attachinent 4D SENSOR LIST RECORD NUMBER -
94 DATE - 12/ 9 TIME - 16 30: O PRESSURES 72.72700 72.72400 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.72549 R7D/S 1
81.694 2
84.780 3
83.094 4
78.682 5
80.247 6
81.552 7
80.935 8
78.943 9
79.038 10 79.109 11 79.061 12 85.755 23 85.507 14 85.398 15 90.812 16 90.313 17 90.004 18 91.026 19 87.843 20 87.748 21 74.747 22 76.382 23 76.738 24 76.311 25 76.098 26 77.662 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 47.744 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.276 DEW CELLS 1
68.822 2
68.689 3
70.206 4
68.867 5
76.470 6
75.773 INACT 76.311 INACT 74.747 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVi; DEW CELL 72.299 14.43028 AMBIENT PRESS
.3930913 VAPOR PRESS 72.33241 DRY PRESSURE
.1198 0
FLOWS TOTAL FLOW 0
Page 13 of 27
l D SENSOR LIST
- a*****************
RECORD NUMBER -
95 DATE - 12/ 9 TIME - 16:45: O PRESSURES 72.72300 72.71900 2
1 0.00000 0.00000 INACT INACT 1
0.00000 0.00000 INACT INACT AVG PRESSURE 72.72100 RTD/S 1
81.742 2
84.756 3
83.118 4
78.658 5
80.247 6
81.552 7
80.911 8
78.943 9
79.038 10 79.109 11 79.061 12 85.798 13 85.464 14 85.355 15 90.741 16 90.194 17 89.814 18 90.955 19 87.795 20 87.700 21 74.747 22 76.382 23 76.714 24 76.287 25 76.098 26 77.639 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.686 INACT 0.036 INACT 0.000 INACT 0.000 IPACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.861 DEW CELLS 1
68.778 2
69.044 3
70.228 4
68.867 5
76.437 6
75.806 INACT 76.287 INACT 74.747 INACT 0.000 INACT 0.000 JNACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.349 14.43092 AMBIENT PRESS-
.3937508 VAPOR PRESS 72.32725 DRY PRESSURE
.263 0
rL0wS TOTAL FLOW 0
Page 14 of 27
Attaciunent 4D SENSOR LIST RECORD NUMBER - 96 DATE - 12/ 9 TIME - 17: 02 0 PRESSURES 72.71900 72.71600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.71750 RTD/S 1
81.671 2
84.780 3
83.118 4
78.658 5
80.247 6
81.552 7
80.935 6
78.966 9
79.038 10 79.109 11 79.061 12 85.755 13 85.421 14 85.355 15 90.693 16 S0.099 17 89.696 1r 90.836 19 87.748 20 87.653 21 74.723 22 76.358 23 76.714 24 76.311 25 76.074 26 77.639 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.578 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.847 DEW CELLS 1
68.789 2
69.088 3
70.217 4
68.044 5
76.448 6
75.806 INACT 76.311 INACT 74.723 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.366 14.42934 AMBIENT PRESS
.3939743 VAPOR PRESS 72.32352 DRY PRESSURE FLOWS
.3025 0
TOTAL 'AMi 0
Page 15 of 27 l
Attadiment 4D t+
SENSOR LIST RECORD NUMBER -
97 DATE - 12/ 9 TIME - 17:15: O PRESSURES 72.71500 72.71200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.71350 RTD/S 1
81.647 2
84.780 3
83.094 4
78.658 5
80.271 6
81.552 7
80.935 8
78.966 9
79.038 10 79.132 12 79.061 12 85.798 13 85.421 14 85.355 15 90.432 16 90.028 17 89.672 18 90.788 19 87.724 20 87.629 21 74.723 22 76.335 23 76.690 24 76.311 25 76.074 26 77.662 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.441 INACT 0.036 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.840 DEW CELLS 1
68.667 2
69.044 3
70.339 4
68.944 5
76.437 6
75.773 INACT 76.311 INACT 74.723 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.349 14.4319 AMBIENT PRESS
.3937543 VAPOR PRESS 72.31975 DRY PRESSURE
.1955 0
FLOWS TOTAL FLOW 0
Page 16 of 27
. D SENSOR LIST RECORD UUMbER -
98 DATE - 12/ 9 TIME - 17:30: 0 PRESSURES 72.71200 72.70900 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT "uACT AVG PL '9SURE 72.71049 RTD/S 1
81.694 2
84,803 3
83.094 4
78.65B 5
80.271 6
81.552 7
80.935 8
78.990 9
79.061 10 79.109 11 79.061 12 85.841 13 85.464 14 85.355 15 90.503 16 89.981 17 89.648 18 90.693 19 87.724 20 87.629 21 74.700 22 76.335 23 76.690 24 76.264 25 76.050-26 77.591 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.373 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.831 DEW CELLS 1
68.800 2
69.077 3
70.339 4
09.077 5
76.426 6
75.784 INACT 76.264 INACT 74.700 D
INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG L'E:( CELL 72.387 14.43126 AMBIENT PRESS
.3942606 VAPOR PRESS DRY PRESSURE 72.31623
.2202 0
TLOWS TOTAL FLOW 0
Page 17 c.
. D SENSOR LIST RECORD NUMBER - 99 DATE - 12/ 9 TIME - 17:45: O PRESSURES 72.70900 72.70600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.70750 RTD/S 1
81.694 2
84.803 3
83.118 4
78.658 5
80.271 6
81.552 7
80.935 8
78.966 9
79.061 10 79.132 11 79.061 12 85.755 13-85.464 14 85.355 15 90.384 16 89.933 17 89.601 18 90.670 19 87.724 20 87.629 21 74.700 22 76.335 23 76.690 24 76.264 25 76.050 26 77.615 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.334 INACT 0.036 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
.0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 int.CT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.827 DEW CELLS 1
68.878 2
69.088 3
70.361 4
69.110 5
76.448 6
75.795 INACT 76.264 INACT 74.700 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 4
AVG DEW CELL 72.415 14.43637 AMBIENT PRESS
.3946239 VAPOR PRESS 72.31288 DRY PRESSURE
.2169 0
FLOWS TOTAL FLOW 0
Page 18 of 27
Attadunent 4D SENSOR LIST RECORD NUMBER -
100 DATE - 12/ 9 TIME - 18: 0: O PRESSURES 72.70600 72.70300 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.70450 RTD/S 1
81.694 2
84.003 3
83.142 4
78.634 5
80.271 6
81.528 7
80.935 8
78.990 9
79.061 10 79.132 11 79.061 12 85.755 13 85.464 14 85.398 15 90.289 16 89.886 17 89.553 18 90.646 19 87.700 20 87.605 21 74.700 22 76.287 23 76.667 24 76.240 25 76.050 26 77.591 INACT 0.000 INACT 0.000 INACT
-0.000 INACT 0.000 INACT 47.207 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.815 DEW CELLS 1
68.807 2
69.243 3
70.350 4
69.154 5
76.459 6
75.751 INACT 76.240 INACT 74.700 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 AVO DEW CELL 72.431 14.43858 AMBIENT PRESS
.3948479 VAPOR PRESS i
72.30965 DRY PRESSURE FLOWS
.2548 0
TOTAL FLOW O
Page 19 of 27 i
i
. D
- ..******************aa SENs0R LIST RECORD NUMBER -
101 DATE - 12/ 9 TIME - 18:15: O PRESSURES 72.10300 72.70000 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.70150 RfD/S 1
81.671 2
84.803 3
83.142 4
78.634 5
80.247 6
81.576 7
80.935 0
78.990 9
79.085 10 79.156 11 79.085 12 85.755 13 85.507 14 85.398 15 90.266 16 09.862 17 89.529 18 90.598 19 87.700 20 87.605 21 74.652 22 76.311 23 76.667 24 76.240 25 76.027 26 77.591 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.129 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.813 DEW CELLS 1
68.999 2
69.176 3
70.427 4
69.132 5
76.437 6
75.740 INACT 76.240 INACT 74.652 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL
'72.443 14.43509 AMBIENT PRESS
.3950066 VAPOR PRESS 72.3065 DRY PRESSURE 0
0 FLOWS TOTAL FLOW 0
Page 20 of 27
Attadunent 4D SENSOR LIST RECORD NUMBER -
102 DATE - 12/ 9 TIME - 18:30: O PRESSURES 72.70100 72.69700 2
1 INACT -
0.00000 INACT -
0.00000 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.69900 RTD/S 1
81.694 2
84.803 3
83.142 4
78.634 5
60.247 6
81.576 T
80.959 8
78.966 9
79.085 10 79.156 11 79.061 12 85.755 13 85.507 14 85.398 15 90.171 16 89.862 17 89.529 18 90.551 19 87.676 20 87.581 21 74.676 22 76.287 23 76.643 24 76.240 25 76.027 26 77.544 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.070 INACT O.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT ' O.000 INACT 0.000 INAct 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.803 DEW CELLS 3
68.977 2
69.243 3
70.460 4
69.221 6
76.404 6
75.717 INACT 76.240 INACT 74.676 1HACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELI.
72.451 14.43062 AMBIENT PRESS
.3951125 VAPOR PRESS 72.30389 t
DRY PRESSURE
.3042 0
FLOWS TOTAL FLOW 0
Page 21 of 27 8
m________
Attaclunent 4D SENSOR LIST RECORD NUMBER -
103 DATE - 12/ 9 TIME - 18:45: O PRESSURES 72.69800 72.69500 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT l
AVG PRESSURE 72.69650 RTD/S 1
81.694 2
84.827 3
83.166 4
78.658 5
80.271 6
D1.576 7
80.959 8
78.990 9
79.085 10 79.156 11 79.109 12 85.755 13 85.507 14 85.440 15 90.218 16 89.838 17 89.434 18 90.527 19 87.700 20 87.581 21 74.652 22 76.264 23 76.667 24 76.240 25 76.027 26 77.568 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.012 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.810 DEW CELLS 1
68.988 2
69.110 3
70.538 4
69.287 5
76.393 6
75.695 INACT 76.240 INACT 74.652 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.444 14.4319 AMBIENT PRESS P
.3950137 VAPOR PRESS 72.30149 DRY PRESSURE
.2861 0
FLOWS TOTAL FLOW 0
Page 22 of 27
Attedunent 4D
- ........***e SENSOR LIST RECORD NUMBER -
104 DATE - 12/ 9 TIME - 19: On O PRESSURES 72.69500 72.69200 2
1 0.00000 0.00000 IHACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.69350 RTD/S 1
81.694 2
84.874 3
83.166 4
78.658 5
80.271 6
81.600 7
80.959 8
78.990 9
79.085 10 79.180 11 79.109 12 85.755 13 05.507 14 85.440 15 90.123 16 89.814 17 89.434 18 90.503 19 87.676 20 87.558 21 74.652 22 76.264 23 76.643 24 76.216
-25 76.003 26 77.568 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.953 INACT 0 039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
-0.000 INACT 0.000 INACT 0.000 1HACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 IHACT 0.000 AVG RTD 79.804 DEW CELLS 1
68.988 2
68.999 3
70.527 4
69.331 5
76.393 6
75.740 INACT 76.216 INACT 74.652 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CEL1 72.440 4
14.43283 AMBIENT PRESS
.3949625 VAPOR PRESS 72.29853 DRY PRESSURE
.1214 0
FLOWS TOTAL FLOW 0
k Page 23 of 27
. D SENSOR LIST RECORD UUMBER -
105 DATE - 12/ 9 TIME - 19:15: O PRESSURES 72.68600 72.68300 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.68449 RTD/S 1
81.718 2
84.851 3
83.189 4
78.634 5
80.247 6
81.576 7
80.983 8
79.014 9
79.085 10 79.180 11 79.109 12 85.798 23 85.550 14 85.440 15 90.194 16 89.790 17 89.458 18 90.503 19 87.676 20 87.558 21 74.628 22 76.264 23 76.643 24 76.216 25 76.003 26 77.520 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.865 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT O.000 AVG RTD 79.802 DEW CELLS 1
69.121 2
69.176 3
70.604 4
69.365 5
76.370 6
75.706 INACT 76.216 INACT 74.628 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.489 14.43347 AMBIENT PRESS
.3956132 VAPOR PRESS 72.28888 DRY PRESSURE
.2679 0
FLOWS TOTAL FLOW 0
Page 24 of 27
M
- -... - D
- ease **eemeneena**
srgson Lysy i
RECORD NUMBER -
106 DATE - 12/ 9 TIME - 19:30: 0 PRESSURES 72.67000 72.67400 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.67500 RTD/S 1
81.694 2
84.874 3
83.189 4
78.658 5
80.295 6
81.600 7
80.983 8
78.990 9
79.061 10 79.180 11 79.109 12 85.798 13 85.550 14 85.483 15 90.147 16 89.790 17 89.458 18 90.527 19 87.653 20 87.558 21 74.628 22 76.240 23 76.619 24 76.193 25 75.979 26 77.520 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 46.846 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.796 DEW CELLS 1
69.254 2
69,387 3
70.660 4
69.420 5
76.370 6
75.695 INACT 76.193 INACT 74.628 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.552 14.43126 AMBIENT PRESS
.3064495 VAPOR PRESS DRY PRESSURE 72.27956
.2647 0
FLOWS TOTAL FLOW 0
l i
Page 25 of 27
Attadunent 4D eeeeeeeeeeeeeeee*******
SENSOR LIST RECORD NUMBER -
107 DATE - 12/ 9 TIME - 19:45: O PRESSURES 72.66600 2
72.67000 1
0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.66800 RTD/S 1
81.718 2
84.874 3
83.213 4
78.658 5
80.271 6
81.600 7
80.983 8
79.038 9
79.109 10 79.180 11 79.132 12 85.884 13 85.593 14 85.483 15 90.171 16 89.814 17 89.482 18 90.480 19 87.653 20 87.558 21 74.605 22 76.216 23 76.596 24 76.193 25 75.979 26 77.520 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.768 INACT O.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.800 DEW CELLS 1
69.176 2
69.652 3
70.615 4
69.420 5
76.337 6
75.673 INACT 76.193 INACT 74.605 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.561 14.43092 AMBIENT PRESS
.3965711 VAPOR PRESS 72.27143 DRY PRESSURE
.2515 0
FLOWS TOTAL FLOW
-0 L
Page 26 of 27
.. D SENSOR LIST RECORD NUMBER -
108 DATE - 12/ 9 TIME - 20: 0: O PRESSURES 72.66200 72.65000 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.66000 RTD/S 1
81.671 2
84.898 3
83.189 4
78.682 5
80.271 6
81.600 7
81.006 8
79.014 9
79.109 10 79.204 11 79.132 12 85.884 13 85.636 14 85.526 15 90.172 16 89 767 17 89.434 18 90.480 19 87.629 20 87.534 21 74.605 22 76.240 23 76.596 24 76.193 25 75.979 26 77.520 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 46.689 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
'O.000-INACT C.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.803 DEW CELLS 1
69.154 2
69.232 3
70.671 4
69.464 5
76.326 6
75.706 INACT 76.193 INACT 74.605 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.512 14.42934 AMBIENT PRESS VAPOR PRESS
.3959228 DRY PRESSURE 72.26408' 0
0 FLOWS TOTAL FLOW 0
Page 27 of 27
l Attaclunent 5A TOTAL TIME CALCULATION RESULTS DATE 13-1991 TIME - 09:34:29 CORR.
LSF UPPFR MEASURED VAPOR DEW AIR LEAK CONF LEAK TIME TEMP PRESS POINT PRESS RATE LEVEL RATE l
2015 539.473 0.3967 72.573 72.263 0.0000 0.00000 0.00000 2030 539.473 0.3969 72.587 72.261 0.0000 0.00000 0.23811 2045 539.477.0.3974 72.622 72.260 0.2132 0.00000 0.21325 2100 539.482 0.3978 72.656 72.259 0.2281 0.43169 0.23604 2115 539.479 0.3981 72.674 72.257 0.2126 0.29549 0.20642 2130 539.485 0.3983 72.690 72.256 0.2132 0.26806 0.21839 2145 539.487 0.3985 72.706 72.255 0.2058 0.24686 0.20333 2200 539.493 0.3994 72.771 72.254 0.2120 0.25755 0.22526 2215 539.494 0.3989 72.737 72.254 0.2053 0.24269 0.19975 2230 539.492 0.3993 72.762 72.252 0.1987 0.23237 0.19366 2245 539.495.0.3998 72.801 72.251 0.1943 0.22435 0.19374 2300 539.498 0.3994 72.771 72.251 0.1895 0.21708 0.18795 2315 539.505 0.4001 72.823 72.249 0.1886 0.21583 0.19631 2330 539.500 0.4004 72.848 72.249 0.1841 0.20900 0.18227 2345 539.502 0.4001 72.828 72.248 0.1800 0.20344 0.17939 0 539.515 0.4010 72.894 72.246 0.1807 0.20721 0.19501 15 539.508 0.4012 72.908 72.245 0.1789 0.20303 0.18441 30 539.508 0.4014 72.924 72.245 0.1765 0.19943 0.17942 45 539.516 0.4014 72.919 72.244 0.1755 0.19876 0.18423
'100 539.514 0.4016 72.937 72.243 0.1736 0.19566 0.17782 115 539.520 0.4024 72.995 72.242 0.1729 0.19556 0.18286 130 539.519 0.4024 72.995 72.241 0.1719 0.19398 0.17970 145 559.523 0.4027 73.019 72.240 0.1710 0.19306 0.17972 200 539.528 0.4029 7'J. 032 72.239 0.1708 0.19329 0.18218 215--539.532 0.4028 T3.029 72.238 0.1703 0.19261 0.18025 230' 539.537 0.4031
/3.048 72.237 0.1700 0.19250 0.18091 245 539.542 0.4039 73.105 72.236 0.1706 0.19432' O.18621 300 539.545 0.4038 73.100 72.236 0.1704 0.19360 0.18122 315 539.544 0.4041 73.123 72.234 0.1701 0.19311 0.17990 330c 539.554 0.4044
- /3.14 6 -
72.234 0.1703 0.19396 0.18372 345 539.558 0.4046 73.158 72.233 0.1705 0.19409 0.18271 400- 539.566 0.4047 73.162-72.232 0.1707 0.19465 0.18393 415 -539.569 0.4051 73.195 72.231 0.1710 0.19507 0.18397 MEASURED LEAK. RATE USING TOTAL TIME:
0.171030
-THE MEAN TOTAL TIME RATE OF 0.183109 IS LESS THAN ALLOWADLE MAXIMUM RATE OF
.635 Page 1 of 1 v
,-mm
.we--
4 u
TOTAL TIME - TYPE A TEST COOPER - DECEMBER 9-10,1991 8.988 TOTAL TIME - LSF
.75 MAX ALLOUED 8.888 TOTAL TIME - UCL
'8.788 8.588
.x 8.588
/
480 0
4 4
Y CZ_o m
o
~-
i 8.188 l
8.888 I
g h
0.88 8.88-1.68 2.49 3.28 4.88 4.88 5.68 6.48 7.28 8.08 (28:15)
(21:51)
(23:27)
( 1: 3)
( 2:39)
( 4:15) 28:15: 8 DELTA TIME IM fr!OURS REC 189
-141 E
w
. C i
KASS POINT DATE 13-1991 TIME - 09:34:34 CORR.
CONT LSF UPPER VAPOR DEW AIR AIR LEAK CONT TIME TEMP PRESS POINT PRESS MASS RATE LEVEL 2015 539.473 0.3967 72.573 72.263 87694.95 0.00000 0.00000 2030 539.473 0.3969 72.587 72.261 87692.77 0.00000 0.00000 2045 539.477 0.3974 72.622 72.260 87691.05 0.21338 0.00000 2100 539.482 0.3978 72.656 72.259 87688.48 0.23126 0.26716 2115 539.479 0.3981 72.674 72.257 87687.41 0.21218 0.24296 2130 539.485 0.3983 72.690 72.256 87684.98 0.21442 0.23287 2145 539.487 0.3985 72.706 72.255 87683.00 0.20599 0.22175 2200 539.493 0.3994 72.771 72.254 87683.55 0.21503 0.23023 2215 539.494 0.3989 72.737 72.254 87680.35 0.20634 0.22125 2230: 539.492 0.3993 72.762 72.252 87679.03 0.19855 0.21291 2245 539.495 0.3998 72.801 72.251 87677.25 0.19413 0.20660 2300 539.498 0.3994 72.771 72.251 87676.06 0.18912 0.20064 2315 539.505 0.4001 72.823 72.249 87673.43 0.18936 0.19901 2330 539.500 0.4004
-72.848 72.249 87673.30 0.18449 0.19410 2345 539.502 0.4001 72.828 72.248 87672.01 0.18026 0.18959 0 539.515 0.4010 72.894 72.246 87668.23 0.18258 0.19104 15 539.508 0.4012 72.908 72.245 87668.00 0.18109 0.18866 30 539.508 0.4014 72.924 72.245 87667.09 0.17861 0.38576 45 539.516
~0.4014 72.919 72.244 87664.66 0.17822 0.18461 100 539.514 0.4016-72.937 72.243 87664.09 0.17628 0.18233 115 539.520 0.4024 72.995 72.242 87661.54 0.17618 0.18164 130 539.519 0.4024 72.995 72.241 87660.48 0.17539 0.18040 145 539.523 0.4027 73.019 72.240 87658.84 0.17484 0.17943 200 539.528 0.4029 73.032 72.239 87656.67 0.17503 0.17924 215 539.532 0.4028 73.029 72.238 87655.43 0.17483 0.17869 230 539.537 0.4031 73.048 72.237 87653.63 0.17485 0.17841 245 539.542 0.4039 73.105 72.236 87650.73 0.17600 0.17949
-300 539.545 0.4038 73.100 72.236 87650.25 0.17601 0.17924 315 539.544 0.4041 73.123 72.234 07648.94 0.17580 0.17881 330 539.554 0.4044 73.146 72.234 87646.28 0.17637-0.17923 345 539.558 0.4046 73.158 72.233 87644.88 0.17669 0.17938 400.539.566 -
0.4047 73.162 72.232 87642.87 0.17720 0.17978 415 53Q.569 0.4051 73.195 72.231' 87641.17 0.17768 0.18013 MAX ALLOWABLE LEAK RATE :
.635 75% OF MAX ALLOWABLE LEAK RATE
.47625 EPRI EQUATION #6 IS SATISFIED.
EPRI EQUATION #7 IS SATISTIED p
L Page 1-of 1
MASS POINT - TYPE A TEST COOPER - DECEMBER 9-10.1991 B.988 MASS POINT - LSF
.75 MAX ALLOUED 8.888 MASS P0ltil - UCL 8.788 B.688
- /.
8.588
/
8.488 D
8.300 A
Y
.<%h M.188 8.888 8.88 8.88 1.68 2.48 3.28 4.88 4.88 5.68 6.48 7.28 8.88 I.
(20:15)
(21:51)
(23:27)
( 1: 3)
( 2:39)
( 4:15)
E 28:15: 8 DELTA TIME IN HOURS REC 189 - 141 l
, e
Attaclunent 5E MASS LOSS DATE 13-1991 71ME - 09:34:41 REC TIME CONT MASS MASS MASS
-hdM-DELTA AIR-LOSS LOSS LOSS (HOURS)
MASS INCR (I HR)
(x 24) 109 0.00 87694.953 0.000 0.000 0.000 110 0.25 87697.773
-2.180 0.000 0.000 111 0.50 87691.055
-1.719 0.000 0.000 112 0.75 87688.484
-2.570 0.000 0.000 113 1.00 87687.406
-1.078 7.547 181.125 114 1.25 87604.97'
-2.430 7.797 187.125 115 1.50 87683.00's
-1.172 7,250 174.000 116
-1.75 87680.bri 3.258 7 +: 3 8 -
190.500 117 2.00 87680.352
-0.195 7.055 169.313 118 2.25 87679.031
-1,320 5.945 142.688 119 2.50 87677.250
-1.781 6 555 157.313 120 2.75 87676.063
-1.188 4.48-107.625 121-3.00 87673.430
-2.633 6.92L 166.125-122 3,25 87673.305
-0.125 5.727 137.438 123 3.50 87672.008
-1.297 S.242 125.813 124-3.75 87668.227
-3.781 7.836 188.063 125 4.00 87668.000.
-0.227 5.430 130.313 126 4.25 87667.086
-0.914 6.219 149.250 127 4.50 87664.656
-2.430 7.352 176.438 128 4.75 87664.086
-0.570
-4.141 99.375 1129
-5.00 87661.539
-2.547 6.461 155.063
'130 5.25 87660.477
-1.063 6.609 158.625 131 5.50 87658.836
-1.641 5.820 139.688 132 5.75
'87656.672
-2.164 7.414 177.938
-133 6.00 87655.430
-1.242 6.109 146.625 134 6.25 87653.633
-1.797 6.844 164.250 135 6.50:
-87650.727
-2.906
-8.109 194.625 136 6;75 87650.250
-0.477 6.422 154.125
-137
-7.00 87648.938
-1.313 6.492-155.813
'138 7.25-87646.281
-2.656 7.352 176.438 139-7.50 87644.883
-1.398 5.844 140.250 140-
.7.75-87642.867
-2.016 7.383 177.188 141 8.00 87641.172
-1.695 7.766 186.375 Page 1 of 1
. MEASURED MASS - TYPE A TEST COOPER - DECEMBER 9-10,1991 87.730 g
87.720 1
1 87.718 8
8 87.788 8
_N87.698 87 f
87.678 N
L 87.668 l
S
.87.658 87.648 i
t i
c 8.80 8.88 1.68 2.48 3.28 4.88 4.98 5.68 6.48 7.28.
8.08 g
(20:15)
(21:51)
(23:27)
( 1: 3)
' 2:39)
( 4:15)
E-2H :1t;" H DRI.TA TTMF IN HailRR REC iWJ - 141 g
l
~
.7
! AVERAGE PRESSURT
~"YPT A TEST COOPER - DECEMB!.
'1
... ~
72.688 72.675 72.678 72.665 72.660.-
7N P
7235 l
S I
72.658 72.645
w 72.648 w N l
72.635 j
g
'8.88 0.88 1.68 2.48
.3.28 4.88 4.08 5.68 6.48 7.28 8.08 3.-
(28:15)
(21:51)
(23:27)
( 1: 3)
( 2:39)
(.4:15)
E I
20:15: DELTA TIME IM HOURS REC 189 - 141 O.
,d AVERAGE TEMPERATURE
' TYPE A TEST COOPER'- DECEMBER 9-10,1991 79.912 79.988
.79.887
/
79.875
/
['
D E
79.862
/
-G R
79.858 g
E p \\- /;~ e E
79.837
/
g f.)
79.825 F
79 812 j j
./
" 79.888 I
8.88 8.88
.1.68 2.48 3.28 4.00 4.88 5.66 6.48 7.28 8.88 (28:15)
-(21:51)-
(23:27)
( 1: 3)
( 2:39).
( 4:15) 3" 20:15: 8 DELTA TIME IM HOURS REC 189 - 141.
1 q-AVERAGE VAPOR 1 PRESSURE - TYPE A TEST COOPER - DECEMBER 9-10,1991 :
8.485 8.484 8.483
,/
0.482 8.481
/
l P
8.488
[N' i
S
/'N/
I 8.395
/'V
/
8>398,
-j 8.397
'8.396 E
0.88
- 8.88 1.68 2.48-3.20' 4.88 4.88-5.68
'6.48 7.28 8.88 3
(28:15)
(21:51)
(23:27)
( 1: 3)
( 2:39)
( 4:15) j.
j28:15:8 DELTA TIME IN HOURS REC 189 -- 141
-i
)
a
+
r
- _ _ _ _ _ _ _ _ _ - _ _ - _ _ _ - _ - _ _ _ _ _ _ _ _ _ J ENVIRON *4ENT LISTING DATE 13-1991 TIME - 09:34:50 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE 109 9 2015 539.473 0.3967 72.2628 78.73 0.3616 0.00000 110 9 2030 539.473 0.3969 72.2611 78.76 0.3615
-0.00674 111 9 2045 539.477 0.3974 72.2601 78.85 0.3615
-0.00391 112 9 2100 539.482 0.3978 72.2587 78.92 0.3615
-0.00580 113 9 2115 539.479 0.3981 72.2574 78.98 0.3615
-0.00491 114 9 2130 539.485 0.3983 72.2562 79.01 0.3615
-0.00494 115 9 2145 539.487 0.3985 72.2555 79.04 0.3615
-0.00281 116 9 2200 539.493 0.3994 72.2536 79.20 0.3615
-0.00751 117 9 2215 539.494 0.3989 72.2536 79.11 0.3615
-0.0vo21 118 9 2230 539.492 0.3993 72.2522 79.18 0.3615
-0.00528 119 9 2245 539.495 0.3998 72.2512 79.28 0.3615
-0.00409 120 9 2300 539.498 0.3994 72.2506 79.19 0.3615
-0.00241 121 9 2315 539.505 0.4001 72.2494 79.31 0.3615
-0.00479 122 9 2330 539.500 0.4004 72.2406 79.39 0.3615
-0.00336 123 9 2345 539.502 0.4001 72.2479 79.33 0.3615
-0.00287 124 10 0
539.515 0.4010 72.2465 79.47 0.3614
-0.00552 125 10 15 539.508 0.4012 72.2453 79.53 0.3614
-0.00435 126 10 30 539.508 0.4014 72.2446 79.57 0.3614
-0.00284 127 10 45 539.516 0.4014 72.2436 79.54 0.3614
-0.00369 128 10 100 539.514 0.4016 72.2429 79.59 0.3614
-0.00299 129 10 115 539.520 0.4024 72.2416 79.73 0.3614
-0.00516 130 10 130 539.519 0.4024 72.2406 79.73 0.3614
-0.00400 131 10 145 539.523 0.4027 72.2398 79.79 0.3614
-0.00330 132 10 200 539.528 0.4029 72.2386 79.81 0.3614
-0.00473 133 10 215 539.532 0.4028 72.2382 79.79 0.3614
-0.00177 134 10 230 539.537 0.4031 72.2374 79.83 0.3614
-0.00305 135 10 245 539.542 0.4039 72.2356 79.97 0.3614
-0.00711 136 10 300 539.545 0.4038 72.2357 79.95 0.3614 0.00024 137 10 315 539.544 0.4041 72.2344 80.01 0.3614
-0.00516 138 10 330 539.554 0.4044 72.2336 80.04 0.3614
-0.00327 139 10 345 539.558 0.4046 72.2329 80.07 0.3613
-0.00266 140 10 400 539.566 0.4047 72.2323 80.06 0.3613
-0.00223 141 10 415 539.569 0.4051 72.2314 80,14 0.3613
-0.00375 s
Page 1 of 3 J
l f
l ENVIRONMENT LISTING DATE 13-1991 ZONE -
1 TIME - 09:34:53 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE 109 9 2015 542.497 0.3606 72.2973 64.89 0.3597 0.00000 110 9 2030 542.509 0.3611 72.2949 64.95 0.3597
-0.00970 111 9 2045 542.518 0.3621 72.2939 65.11 0.3597
-0.00409 112 9 2100 542.527 0.3630 72.2920 65.25 0.3597
-0.00742 113 9 2115 542.536 0.3633 72.2907 65.29 0.3597
-0.00537 114 9 2130 542.549 0.3630 72.2892 65.35 0.3596
-0.00595 115 9 2145 542.563 0.3644 72.2876 65.42 0.3596
-0.00629 116 9 2200 542.564 0.3654 72.2856 65.62 0.3596
-0.00836 117 9 2215 542.575 0.3649 72.2861 65.50 0.3596 0.00217 118 9 2230 542.582 0.3654 72.2846 65.57 0.3596
-0.00601 119 9 2245 542.588 0.3663 72.2827 65.72 0.3596
-0.00751 120 9 2300 542.593 0.3658 72.2822 65.63 0.3596
-0.00217 121 9 2315 542.610 0.3667 72.2813 65.75 0.3596
-0.00363 122 9 2330 542.613 0.3675 72.2795 65.88 0.3595
-0.00696 123 9 2345 542.618 0.3671 72.2789 65.79 0.3a95
-0.00232 124 10 0
542.638 0.3684 72.2776 66.00 0.3595
-0.00555 125 10 15 542.637 0.3688 72.2762 66.06 0.3595
-0.00537 126 10-30 542.638 0.3693 72.2747 66.15 0.3595
-0.00607 127 10 45 542.C46 0.3692 72.2738 66.11 0.3595
-0.00354 128 10 100 542.656 0.3696 72.2734 66.17 0.3595
-0.00168 129 10 115 542.670 0.3710 72.2710 66.40 0.3595
-0.00977 130 10 130 542.672 0.3708 72.2702 66.35 0.3595
-0.00308 131 10 145 542.675 0.3713 72.2697 66.42 0.3595
-0.00177 132 10 200 542.687 0.3716 72.2684 66.46 0.3594
-0.00540 133 10 215 542.688 0.3716 72.2674 66.46 0.3594
-0.00412 134 10 230 542.705 0.3721 72.2669 66.51 0.3594
-0.00183 135 10 245 542.710 0.3734 72.2646 66.73 0.3594
-0.00919 136 10 300 542.723 0.3733 72.2647 66.69 0.3594 0.00043 137-10 315 542.720 0.3739 72.2631 66.80 0.3594
-0.00650 138 10 330 542.742 0.3743 72.2617 66.82 0.3594
-0.00543 139 10 345 542.745 0.3746 72.2614 66.86 0.3594
-0.00113 140 10 400 542.761 0.3748 72.2602 66.88 0.3594
-0.00507 141 10 415 542.767 0.3752 72.2598 66.93 0.3593
-0.00143 Page 2 of 3 d
4 **T
- 166 h.*44-g Attaclunent 5J -
ENVIRONMENT LISTING DATE 13-1991 ZONE -
2 TIME - 09:34:55 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR NUM PRESSURE PRESSURE HUMIDITY DENSITY. VARIANCE 109 9 2015=
535.847 0.4450 72.2160 99.47 0.3638 0.00000 110 9 2030 535.835 0.4449 72.2151 99.47 0.3638
-0.00333 111 9 2045 535.831 0.4445 72.2145 99.41 0.3638
-0.00275 112 9 2100 535.831 0.4444 72.2136 99.38 0.3638
-0.00333 113 9 2115 535.815 0.4444 72.2125 99.45 0.3638 -0.00433 114 9 2130-535.811 0.4443 72.2117 99.42 0.3638 -0.00336 115 9 2145 535.799 0.4440 72.2120 99.39 0.3638 0.00131 116 9 2200 535.811 0.4445 72.2105 99.48 0.3638
-0.00629 117 9 2215 535.799 0.4442 72.2098 99.44 0.3638
-0.00269 118 9 2230 535.788 0.4443 72.2087 99.50 0.3638
-0.00433 119 9 2245 535.788 0.4443 72.2087 99.50 0.3638 0.00000 120 9 2300 535.768 0.4440 72.2080 99.43 0.3638
-0.00269 121 9 2315 535.784 0.4444 72.2066 99.53 0.3638
-0.00562 122 9 2330 535.768 0.4441 72.2069 99.53 0.3638 0.00098 123 9 2345 535.768 0.4440 72.2060 99.51 0.3638
-0.00369 124 10 0
533.772 0.4442 72.2048 99.53 0.3638
-0.00464 125 10 15 535.756 0.4442 72.2038 99.59 0.3638
-0.00400 126 10 30 535.756 0.4440 72.2040 99.53 0.3638 0.00098
. 0.00400 127 10 45 535.764 0.4440 72.2030 99.51 0.3638 123 10 100 535.748 0.4440 72.2020 99.56 0.3638
-0.00400 129' 10 115
-535.744 0.4438 72.2022 99.53 0.3638 0.00064 130 10 130 535.740 0.4441 72.2009 99.62 0.3638
-0.00531 131 30 145' 535.744 0.4443 72.1997 99.64
.0.3638
-0.00467 132 1.0 200 535.740 0.4442 72.1988 99.64 0.3638
-0.00366 133 10 215 535.748 0.4440 72.1990 99.58 0,3637 0.00064 134 10 230' 535.740 0.4440 72.1980 99.60 0.3637
-0.00400 135 10 245x 535.744 0.4440 72.1970 99.59 0.3637
-0.00400 136 10 300 535.736 0.4440 72.1970 99.62 0.3637 0.00000 137 10 315 535.736 0.4439 72.1961 99.58 0.3637
-0.00333 138-10 330 535.732 0.4441 72.1959 99.65 0.3637
-0.00098 139-10 345 535.736 0.4441 72.1949 99.63 0.3637
-0.00400-140 10 400 535.736 0.4439 72.1951 99.58 0.3637 0.00098 141 10 415 S35.736 0.4444 72.1936 99.71 0.3637
-0.00629 Page 3 of 3
Attadunent 5K SENSOR LIST RECORD NUMBER -
109 DATE - 12/ 9 TIME - 20:15: O PRESSURES 72.66100 72.65800 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PHESSURE 72.65950 RTD/S 1
81.694 2
84.922 3
83.213 4
78.706 5
80.295 6
81.600 7
81.006 8
79.038 9
79.156 10 79.204 11 79.156 12 85.927 13 85.593 14 85.526 15 90.099 16 89.767 17 89.387 18 90.456 19 87.629 20 87.534 21 74.605 22 76.216 23 76.596 24 76.169 25 75.979 26 77.496 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 46.611 INACT 0.039 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.803 DEW CELLS 1
69.176 2
69.497 3
70.726 4
69.553 5
76.337 6
75.695 INACT 76.169 IF CT 74.605 INACT 0.000 INACT 0.000 INACT 0.000 I h..CT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.573 AMBIENT PRESS -
14.43028
.3967262 VAPOR PRESS DRY PRESSURE 72.26277
.2647 0
FLOWS TOTAL FLOW 0
Page 1 of 33
Attoclunent 5K SENSOR LIST RECORD NUMBER -
110 DATE - 12/ 9 TIME - 20:30: O PRESSURES 72.66000 72.65600 2
1 0.00000 INACT -
0.00000 INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.65800 RTD/S 1
81.718 2
84,922 3
83.213 4
78.729 5
80.295 6
81.623 7
81.030 8
79.061 9
79.132 10 79.204 11 79.156 12 85.927 13 85.636 14 85.569 15 90.123 16 89.767 17 89.458 18 90.456 19 87.605 20 87.534 21 74.581 22 76.216 23 76.572 24 76.169 25 75.932 26 77.520 INACT 0.000 INACT 0.000 INACT 0.000
.INACT 0.000 INACT 46.572 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000
.INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
.0.000 INACT 0.000 AVG RTD 79.803 DEW CELLb 1
69.243 2
69.531 3
70.770 4
69.531 5
76.348 6
75.662 INACT 76.169 INACT 74.581 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT.
0.000 INACT 0.000 AVG DEW CELL 72.587 14.429 AMBIENT PRESS VAPOR PRESS
.3969183 DRY PRESSURE 72.26109 FLOWS
.0951' O
TOTAL FLOW 0
Page 2 of 33
> K SENSOR LIST RECORD NUMBER -
111 DATE - 12/ 9 TIME - 20:45: O PRESSURES 72.65900 72.65600 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.65750 RTD/S 1
81.742 2
84.946 3
83.237 4
78.753 5
80.318 6
81.647 7
81.030 8
79.038 9'
79.132 10 79.227 11 79.156 12 85.970 13 85.679 14 85.569 15 90.052 16 89.767 17 89.434 18 90.432 19 87.629 20 87.510 21 74.557 22 76.193 23 76.596 24 76.193 25 75.932 26 77.496 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 46.533 INACT 0.039 INACT-0.000 INACT-0.000 INACT 0.000 INACT O.000 INACT
-0.000 INACT
'O.000 INACT 0.000 INACT 0.000
'INACT 0.000
.INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 AVG RTD 79.807 DEW CELLS 1-
~69.420 2
69.641 3
70.770 4
69.553 5
76.326 6
75.640 INACT-76.193 INACT 74.557 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.622 14.42934 AMBIENT PRESS
.3973913 VAPOR PRESS 72.26011 DRY PRESSURE
.2186 0
FLOWS
~
TOTAL FLOW O
Page 3 of 33 l
Attaclunent 5K SENSOR LIST RECORD NUMBER -
112 DATE - 12/ 9 TIME - 21: 0: O PRESSURES 72.65800 72.65500 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT-AVG PRESSURE 72.65649 RTD/S 1
81.766 2
84.993 3
83.260 4
78.753 5
80.318 6
81.623 7
81.030 8
79.061 9
79.132 10 79.227 11 79.204 12 85.927 13 85.722 14 85.612 15 90.028 16 89.790 17 89.458 18 90.456 19 87.605 20 87.486 21 74.581 22 76.216 23 76.596 24 76.145 25
-75.932 26 77.496 INACT 0.000 INACT 0.000 INACT
-0.000 INACT 0.000 INACT 46.504 INACT 0.039 INACT
-0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000
'INACT
-0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.812 DFW CELLS 1
69.464-2 69.741 3
70.814 4
69.652 5-
-76.326 6
75.618 INACT 76.145 INACT 74.581 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEU CELL 72.656 AMBIENT. PRESS- -
14.42964 VAPOR PRESS'
.3978349 DRY PRESSURE
- 72.25866
.1231
'O FLOWS TOTAL FLOW 0
- Page 4 of 33
Attochment 5K h
SENSOR LIST RECORD NUMBER -
113 DATE - 12/ 9 TIME - 21:15: O PRESSURES 72.65700 72.65400 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.65550 RTD/S 1
81.718 2
84.969 3
83.260 4
78.777 5
80.342 6
81.623 7
81.054 8
79.061 9
79.100 10 79.227 11 79.204 12 86.014 13 85.722 14 85.612 15 90.052 16 89.814 17 89.434 18 90.456 19 87.581 20 87.463 21 74.557 22 76.169 23 76.572 24 76.145 25 75.932 26 77.496 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 46.348 INACT 0.039 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 AVG RTD 79.809 DEW CELLS 1
69.376 2
69.874-3 70.859 4
69.674 5
76.337 6
75.618 INACT - 76.145 INACT 74.557 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG. DEW CELL 72.674 14.42802 AMBIENT PRESS VAPOR PRESS
.398075 72.25743 DRY PRESSURE
.0984
'O TLOWS TOTAL FLOW 0
Page 5 of 33
_. K SENSOR LIST RECORD NUMBER - 114 DATE - 12/ 9 TIME - 21:30: O PRESSURES 72.65600 72.65300 2
1 INACT -
0.00000 INACT -
0.00000 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.6:3450 RTD/S 1
81.766 2
85.017 3
83.260 4
78.777 5
80.318 6
81.647 7
81.077 8
79.085 9
79.180 10 79.251 11 79.180 12 86.014 13 85.765 14 85.655 15 90.123 16 89.790 17 89.458 18 90.456 19 87.558 20 87.486 21 74.557 22 76.193 23 76.572 24 76.121 25 75.932 26 77.473 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.289 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACI 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.815 DEW CELLS 1
69.564 2
69.796 3
70.870 4
69.708 5
76.326 6
75.607 INACT 76.121 INACT 74.557 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 AVG DEW CELL 72.690 AMBIENT PRESS - 14.42836 VAPOR PRESS
.3982976 72.2562 DRY PRESSURE FLOWS
.2169 0
TOTAL FLOW 0
Page 6 of 33
. K SENSOR LIST RECORD NUMBER -
115 DATE - 12/ 9 TIME - 21:45: O FRESSURES-72.65600 72.65200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.65400 RTD/S 1
81.766 2
84.993 3
83.284 4
78.800 5
80.342 6
81.647 7
81.077 8
79.085 9
79.180 10 79.275 11 79.227 12 86.057 13 85.808 14 85.697 15 90.052 16 89.838 17
.89.434 18 90.480 19 87.558 20 87.463 21 74.534 22 76.169 23 76.548 24 76.121 25 75.932 26 77.473 INACT 0.000 INACI O.000 INACT 0.000 INACT-0.000 INACT 46.230 INACT 0.039 INACT O.000
-INACT
'O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INI.CT.
0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 AVG RTD 79.817 DEW CELLS lt 69.453' 2
69.962 3
70.947 4
69.763 5
76.304 6
75.585 INACT 76.121 INACT 74.534 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 AVG DEW CELL 72.706 14.43062 AMBIENT PRESS
.3985046 VAPOR PRESS 72.25549
-DRY PRESSURE
.0951-0
-FLOWS TOTAL FLOW.
O P
Page 7 of 33
. K SENSOR LIST RECORD NUMBER -
116 DATE - 12/ 9 TIME - 22: 0: O PRESSURES 72.65500 72.65100 2
1 0.00000 0.00000 INACT INACT INACT -
0.00000 INACT -
0.00000 AVG PRESSURE 72.65300 RTD/S 1
81.766 2
85.017 3
83.284 4
78.824 5
80.366 6
81.647 7
81.077 8
79.085 9
79.180 10 79.275 11 79.275 12 86.014 13 85.808 14 85.697 15 90.004 16 89.790 17 89.410 18 90.456 19 87.558 20 87.463 21 74.557 22 76.169 23 76.572 24 76.145 25 75.932 26 77.473 INACT O.000 INACT O.000 INACT O.000 INACT O.000 INACT 46.162 INACT 0.042 INACT O.000 INACT O.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT O.000 i
AVG RTD 79.823 DEW CELLS 1
69.564 2
70.084 3
71.014 4
69.796 5
76.370 6
75.596 INACT 76.145 INACT 74.557 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT O.000 AVG DEW CELL 72.771 AMBIENT PRESS -
14.429
.3993837 VAPOR PRESS DRY PRESSURE
- 72.25362 FLOWS
.1017 O
TOTAL FLOW O
10 Page 8 of 33
Attechment 5K SENSOR LIST RECORD NUMBER - -117 DATE - 12/ 9 TIME - 22:15: O PRESSURES 72.65100 2 -
72.65400 1
0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.65250 RTD/S 1
81.766 2
85.041 3
83.308 4
78.848 5
80.366 6
81.694 7
81.101 8
79~132 9
79.227 10 79.299 11 79.275 12 86.057 IS 85.765 14 85.697 15 89.886 16 89.790 17 89.363 18 90.503 19 87.534 20 87.439 21 74.534 22 76.169 23 76.548 24 76.145 25 75.908 26 77.473 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 46.094 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 AVG RTD
- 79.824-DEW CELLS 1
69.564 2
69.918 3
70.992 4
69.840 5
76.326 6
75.596 INACT 76.145 INACT 74.534 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.737 14.42517 AMBIENT PRESS
.3989312 VAPOR PRESS DRY 1 PRESSURE
- 72.25356
.2136 0
FLOWS TOTAL FLOW
'O Page 9 of 33
l Attadunent 5K l
SENSOR LIST RECORD NUMBER -
118 DATE - 12/ S TIME - 22:30: O PRESSURES 72.65000 2
72.65300 1
0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.65150 RTD/S 1
81.766 2
85.041 3
83.308 4
78.872 5
80.366 6
81.694 7
81.101 8
79.132 9
79.227 10 79.2C9 11 79.275 12 86.014 13 85.808 14 85.697 15 90.052 16 89.814 17 89.410 18 90.503 19 87.510 20 87.415 21 74.534 22 76.145 23 76.544 24
/6.121 25 75.908 26 77.473 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 46.025 INACT 0.039 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.822 DEW CELLS 1
69.553 2
69.973 3
71.058 4
69.896 5
76.348 6
75.585 INACT 76.121 INACT 74.534 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.762 14.42581 AMBIENT PRESS
.399261 VAPOR PRESS DRY PRESSURE
- 72.25224
.072 0
FLOWS TOTAL FLOW 0
Page 16 of 33
. K SENSOR LIST RECORD NUMBER -
119 DATE - 12/ 9 TIME - 22:45: O PRESSURES 72.65300 72.64900 2
1 0.b0000 INACT 0.00000 INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.65100 RTD/S 1
81.789 2
85.064 3
83.332 4
78.848 5
80.390 6
81.694 7
81.125 8
79.109 9
79.227 10 79.299 11 79.299 12 86.057 13 85.851 14 85.740 15 90.028 16 89.790
-17 89.387 18 90.480 19 87.486 20 87.391 21 74.510 22 76.145 23 76.548 24 76.145 25 75.908 26 77.449 INACT 0.000 INACT 0.000 INACT
-0.000 INACT O.000 INACT 45.967 INACT 0.039 INACT 0.000 INACT.
0.000 INACT 0.000 INACT 0.000 INACT-0.000 INACT O.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT~
0.000 INACT O.000 AVG RTD
-79.825 DEW CELLS 1
69.619 2
70.095 3
71.113 4
69.918 5
76.304-6 75.629
.INACT -76.115 INACT -74.510 INACT 0.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
' AVG DEW CELL 72.801 14.42134 AMBIENT PRESS
.399781 VAPOR. PRESS 72.25122 DRY PRESSURE
.2202 0
flows TOTAL FLOW 0
Page 11 of 33 K
SENSOP LIST RECORD NUMBER -
120 DATE - 12/ 9 TIME - 23: 0: O PRESSURES 72.65200 72.64800 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.65000 RTD/S 1
81.789 2
85.088 3
83.332 4
78.895 5
80.366 6
81.718 7
81.125 8
79.132 9
79.227 10 79.322 11 79.299 12 86.057 13 85.851 14 b5.740 15 89.933 16 89.814 17 89.387 18 90.527 19 87.463 20 87.344 21 74.534 22 76.169 23 76.548 24 76.098 25 75.908 26 77.449 INACT O.000 INACT O.000 INACT O.000 INACT 0.000 INACT 45.850 INACT 0.042 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000
' AVG RTD 79.828 DEW CELLS 1
69.663 2
69.885 3
71.102 4
69.984 5
76.304 6
75.585 INACT 76.098 INACT 74.534 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.771 14.41525
' AMBIENT PRESS
.39938 VAPOR PRESS DRY PRESSURE
- 72.25062 FLOWS
.0687 0
TOTAL FLOW 0
Page 12 of 33
Attedunent 5K l-SENSOR LIST RECORD NUMBER -
121 DATE - 12/ 9 TIME - 23:15: O PRESSURES 72.65100 72.64800 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64951 RTD/S 1
81.837 2
85.088 3
83.355 4
78.872 5
80.390 6
81.694 7
81.149 8
79.132 9
79.251 10 79.346 11 79.346 12 86.057 13 85.851 14 85.783 15 90.076 16 89.814 17 89.434 18 90.503 19 87.463 20 87.368 21 74.510 22 76.145 23 76.572 24 76.098 25 75.908 26 77.449 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.869 INACT O.042 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.835 DEW CELLS 1
69.741 2
70.029 3
71.146 4
69.984 5
76.359 6
75.585 INACT 76.098 INACT 74.510 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000-INACT 0.000 INACT O.000 AVG DEW CELL 72.823 14.41397 AMBIENT PRESS
.4000821 VAPOR PRESS s
DRY PRESSURE
- 72.24942
.2186 0
FLOWS TOTAL FLOW 0
Page 13 of 33
Attadunent 5K SENSOR LIST RECORD NUMBER -
122 DATE - 12/ 9 TIME - 23:30: 0 PRESSURES 72.65100 72.64700 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64900 RTD/S 1-81.837 2
85.088 3
83.332 4
78.895 5
80.390 6
81.718 7
81.149 8
79.156 9
79.299 10 79.346 11 79.322 12 86.057 13 85.894 14 85.783 15 90.028 16 89.814 17 89.410 18 90.503 19 87.439 20 87.320 21 74.486 22 76.169 23 76.548 24 76.074 25 75.884 26 77.425 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.723 INACT 0.042 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT.
0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.830 DEW CELLS 1
69.730 2
70.184 3
71.191.
4 70.029 5
76.337 6
75.574 INACT 76.074 INACT 74.486 INACT 0.000 INACT
.0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL
-72.848 14.41431 AMBIENT PRESS VAPOR PRESS-
.4004205 72.24858 DRY PRESSURE
.1494 0
FLOWS TOTAL FLok 0
Page 14 of 33
. K SENSOR LIST RECORD NUMBER -
123 DATE - 32/ 9 TIME - 23:45: O PRESSURES 72.65000 72.64600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64800 RTD/S 1
81.813 2
85.112 3
83.332 4
78.895 5
80.413 6
81.718 7
81.172 8
79.156 9
79.275 10 79.370
-11 79.370 12 86.057 13 85.894 14 85.826 15 89.981 16 89.790 17 89.387 18 90.527 19 87.415 20 87.320 21 74.534 22 76.121 23 76.524 24 76.098 25 75.884 26 77.425 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 45.625 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT.
0.000 AVG RTD-79.832 OEW CELLS 1
69.719 2
70.040 3
71.180 4
70.095 5
76.326 6
75.574 INACT 76.098 INACT 74.534 INACT 0.000 INACT.
0.000
-INACT 0.000 INACT 0.000-INACT 0.000 INACT 0.000 JNACT 0.000 AVG DEW CELL 72.828 14.41171 AMBIENT PRESS VAPOR PRESS
.400142 72.24786
-DRY PRESSURE
.2153 0
FLOWS TOTAL FLOW 0
Page 15 of 33
4 4 K SENSOR LIST RECORD NUMBER -
124 DATE - 12/10 TI'ME -
0: 0: O PRESSURES
.72.64600 2 -
72.64900 1
0.00000 0.00000 INACT
.INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64751 RTD/S 1
81.884 2
85.159 3
83.379 4
78.919 5-80.413 6
-81.742 7
81.172 8
79.156 9
79.299 10 79.393 11 79.370 12 86.057 13 85.937 14 85.783 15 90.171 16 89.862 17 89.387 18 90.527 19 87.391 20 87.296 21 74.510 22 76.145 23 76.524 24 76.098 25 75.884 26-77.449 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.557 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000
-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.845 DEW CELLS 1
69.752 2
70.383 3
71.202 4
70.106 5
76.326 6
75.596 INACT 76.098 INACT 74.510 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.894 14.41043
. AMBIENT PRESS VAPOR PRESS
.4010273 DRY PRESSURE
- 72.24648
.2218 0
FLOWS TOTAL FLOW 0
Page 16 of 33
l 1
Armchment G 1
SENSOR LIST RECORD NUMBER -
125 DATE - 12/10 TIME - C:15: O PRESSURES 72.64800 72.64500 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64650 RTD/S 1
81.860 2
85.159 3
83.379 4
78.919 5
80.413 6
81.766 7
81.196 8
79.204 9
79.322 10 79.393 11 79.370 12 86.057 13 85.937 14 85.826 15 90.004 16 89.838 17 89.339 18 90.527 19 87.368 20 87.273 21 74.510 22 76.121 23 76.524 24 76.074 25 75.884 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.527 INACT 0.042 INACT 0.000' INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT' O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.838 DEW CELLS 1
69.852 2
70.305 3
71.279 4
70.106 5
76.326 6
75.596 INACT 76.074 INACT 74.510 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT.
0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.908 14.40405 AMBIENT PRESS
.4012284 VAPOR PRESS 72.24527 DRY PRESSURE
.2004 0
FLOWS
-TOTAL FLOW 0
Page 17 of 33
.. K -
SENSOR LIS7 RECORD WUMBER -
126 DATE - 12/10 TIME -
0:30: O PRESSURES 72.64400 2 -
12.64800 1
O<00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRSSSURE 72.64600 STC/S 1
81.860' 2
85.159 3
83.379 4
78.91?
.5 80.437 6
B. 766 7
31.190 8
79.204
- 9.370 12 86.014 9
79.322 10 79.393 11 13 d5.980 14 85.82J 15 90.052 16 69.814 l'i 89.363 18 90.503 19 87.344 20 87.273 21 74.406-22 76,39.1 23 76.524 24 76.098 25 75.884 26 77.4C2 INACT 0.000 INAOT 0.000 JNACT 0.000 INACT 0.000 INACT 45.410 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 IEACT 0.000 IK;.CT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INAC2 0.000 INACT 0.000 INACT 0.000 INAC7 0.000 INACT 0.D00 INACT 0.000
.i AVG RTD 79.838 DEW CELLS 1-69.907 2
70.383 3
71.268 4
70.150 5-76.304 6
75.585 INACT 75.D98 INACT 74 486 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 AVG DEW CELL 72.924 14.40056 AMBIENT FRESS r
.4014331 VAPOR PRESS 72.24456 DRY PRESSURE
.2216 0
FLOWS TOTAL FLOW 0
Page 18 of 33
4 Attachmcnt 5K
- **Ae*********e*******w*
SENSOR LIST RECORD NUMBER -- 127 DATE - 12/10 TIME -
0:45: O PRESSURES 72.04700 72.64300 2
1, 0.00000 0.00000 INACT INACT 0.00000 0.00000
-INACT JNACT AVG PRESSURE-72.64500 RTD/S
.1 01.908 2
85.183 3
83.379 4
78.943 5-80.463-6 81.766 7
81.210 8
79.227 4
79.346 10 79.393 11 79.393 12 30.014 13 (15.980 14 85.826 15 39.933 16 09.838 17 89.410 18 90 503 19 87.320 20 87.225-21 74.4C6 22 76.145 23 76.548 24 76.09B 25.
75.884 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.400 INACT 0.042-INACT 0.000 INACT' O.000-INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 4-INACT 0.009 INACT 0.000 INAC7
-0.000 INACT 0.000 INACT.
0.000 INACT-0.000 INACT O.000 INACT 0.000
-INACT 0.000
-INACT 0.000 AVG RTD 79.846
. DEW CELLS 1.
69.907 2
70.239 3
71.357 4
70.184
'5 176.3~7 6
75.551 INACT 76 098 INACT 74.406 s
'i INACT-0.000-
,INACT.
0.000..
INACT.
0.000 INACT 0.000 INACT~
0.000 INACT-0.000 INACT 0.000 4VG DEWECELL' 71.919 I
/.MBIENT PRESS..
-14.39864
- VAPOR PRESG
.4013661 72.24364 VRY PRESSimd '
.1543-0 FLOWS TOTAL FLOW
-O J.
I i
j.:
L l
Page 19 of 33
-1 I
l
./ _
_ K SENSOR LIST
. RECORD NUMBER -
128 DATE - 12/10 TIME -
1: 0: O PRESSURES 72.64600 72.64300 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64450 RTD/S 1
81.884 2
85.207 3
83.379 4
78.943 5
80.437 6
81.789 7
81.220 8
79.227 9
79.346 10 79.417 11 79.393 12 86.014 13 85.980 14 85.869 15 90.099 16 89.838 l'7 89.410 18 90.551 19 87.296 20 87.225 21 74.486 22 76.121 23 76.501 24 76.050 25 75.884 26 77.4?.5 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 45.352 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.844 DEW CELLS 70.250 1
69.840 3
70.394 3
71.346 e
5 76.337 6.
75.551 INACT 76.050 II.c 74.486 INACT O.000 INAC7 0.000 INACT
'O.000 INl 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.937 14.39604 AMBIENT PRESS
.4016123
' VAPOR PRESS 72.24289.
DRY-PRESSURE
.1823 0
FLOWS TOTAL FLOW-D Page 20 of 33
Attadunent 5K SENSOR LIST RECORD NUMBER -
129 DATE - 12/10 TIME -
1:15: O PRESSURES 72.64600 72.64200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64400 RTD/S 1
81.908 2
85.231 3
83.427 4
78.966 5
80.461 6
81.813 7
81.244 8
79.227 9
79.37v 10 79.417 11 79.393 12 86.057 13 85.980 14 85.869 15 90.076 16 89.862 17 89.458 18 90.527 19 87.296 20 87.225 21 74.486 22 76.121 23 76.524 24 76.050 25 75.061 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 IhACT 0.000 INACT 45.254 INACT 0.042 INACT 0.006 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.J00 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.0?0 INACT 0.090 I N *.CT 0.000 INACT O.000 INACT.
0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVO RTD 79.850 DEN CELLS 1
69.951 2
70.604 3
71.423 4
70.283 5
76.304 6
75.563 INACT 76.050 INACT 74.486 INACT 0 ( 30 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.995 14.39412 AMBIENT-PRESS
.4023963 VAPOR PRESS 72.2416 DRY PRES $vRE
.1231 0
FI ',WS TOTAL TLOW 0
i Page ti of 33 L
y,....,
, K i
SENSOR LIST RECORD NUMDER -
130 OATE - 12/10 TIME -
1:30: O PRESSURES 72.64500 72.64100 2
1 0.000C0 INACT 0.00000 INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64300 RT0/9 1
81.932 2
85.231 3
83.403 4
78.966 5
80.461 6
81.813 7
81.244 8
79.251 9
79.370 10 79.417 11 79.417 12 86.057 13 86.023 14 85.911 15 90.004 16 89.814 17 89.410 38 40.551 19 87.273 20 87.178 21 74.463 22 76.121 23 76.501 24 76.074 25 75.861 26 77.402-INACT 0.000 INACT 0.000 31ACT 0.000 INACT 0.000 INACT 45.215 If4ACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INA6T 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.007 INACT 0.000 AVG RTD 79.849 DEW CELLS 1
69.962 2
70.482 3
71.445 4
70.316 5
76.337 6
75.574 INACT 76.074 INACT 74.463 3'
i.
INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 72.995 14.39157 AMBIENT PRESS
.4023961 VAPOR PRESS 72.2406 DRY PRESSURE
.0605 0
FLOWS TOTAL FLOW 0
Page 22 of 33
Attadunent 5E censor LIST RECORD NUP. DER -
131 DATE - 12/10 TIME -
1:45: O PRESSURES 72.64400 72.64100 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSU"E 72.64250 RTD/S 1
81.908 2
85.231 3
83.427 4
78.990 5
80.508 6
81.013 7
81.267 8
79.251 9
79.370 10 79.441 11 79.441 12 86.014 13 86.023 14 85.911 15 89.981 16 89.838 17 89.410 18 90.551 19 87.249 20 87.154 21 74.486 22 76.098 23 76.524 24 76.050 25 75.884 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.127 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.853 DEW CELLS 1
70.040 2
70.538 3
71.434 4
70.327 5
76.348 6
75.585 INACT 76.050 INACT 74.486 INACT 0.000 INACT 0.000 INACT 0.000
.INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.019 14.38808 AMBIENT PRESS
.402725 VAPOR PRESS 72.23978 DRY PRESSURE
.111:
0 TLOWS TOTAL FLOW 0
t l
l Page 23 of 33
l l
Attadunnt 5K SENSOR LIST RECORD NUMBER -
13?.
DATE - 12/10 TIME -
2 0: 0 l
PRESSURES 72.64300 72.64000 2
1 0.00000 0.00000 IMACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64149 RTD/S 1
81.955 2
85.254 3
83.450 4
78.990 5
80.484 6
81.837 7
81.267 8
79.299 9
79.370 10 79.465 11 79.465 12 86.014 13 86.023 14 85.911 15 90.004 16 89.814 17 89.458 18 90.551 19 87.225 20 87.154 21 74.486 22 76.098 23 76.524 24 76.074 25 75.837 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.107 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
-0.000 INACT 0.000 INACT d.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.858 DEW CELLS 1
70.117 2
70.416 3
71.523 4
70.416 5'
76.348 6
75.574 INACT 76.074 INACT 74.486 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.032 14.38489 AMBIENT PRESS
.4029011 VAPOR PRESS 72.23859 DRY PRESSURE 0
0 FLOWS TOTAL FLOW O
Page 24 of 33
Attedunent 5K
)
i neeeeeeeeeeee*ese******
SENSOR LIST RECORD NUMBER -
133 DATE - 12/10 TIME -
2 15: O PRESSURES 72.64300 72.63900 2
1
+
0.00000 l
1HACT 0.00000 INACT 0.00000 t
0.00000 INACT INACT AVG PRESSURE 72.64100 RTD/S 1
81.908 2
85.302 3
83.450 4
79.014 5
80.500 6
81.837 7
81.267 8
79.299 9
79.393 10 79.465 11 79.465 12 86.014 13 86.023 14 85.011 15 89.981 16 89.838 17 89.434 10 90.551 19 87.201 20 87.106 21 74.486 22 76.090 23 76.524 24 76.090 25 75.861 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 45.020 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.862 DEW CELLS I
70.051 2
70.527 3
71.479 4
70.427 5
76.343 6
75.551 INACT 76.098 INACT 74.486 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.003 AVG DEW CELL 73.029 14.38455 AMBIENT PRESS-
.4028485 VAPOR PHESS 72.23815 DRY PRESSURE 0
0 rLOWS TOTAL FLOW 0
Page 25 of 33
u Attadunent 5K SENSOR LIST RECORD NUMBER -
134 DATE - 12/10 TIME -
2:30: O PRESSURES 72.64200 72.63900 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.64050 RTD/S 1
81.979 2
85.278 3
83.450 4
79.038 5
B0.532 6
81.060 7
81.291 8
79.299 9
79.417 10 79.465 11 79.488 12 86.057 13 86.023 14 85.911 15 90.052 16 89.790 17 89.482 18 90.575 19 87.178 20 87.106 21 74.463 22 76.121 23 76.524 24 76.050 25
?5.884 26 77.378 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.951 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.867 DEW CELLS 1
70.150 2
70.471 3
71.523 4
70.493 5
76.340 6
75.551 INACT 76.050 INACT 74.463 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.048 14.38165 AMBIENT PRESS
.4031179 VAPOR PRESS 72.23739 DRY PRESSURE
.0951 0
FLOWS TOTAL FLOW-O Page 26 of 33
Attachraent 5K SENSOR LIST RECORD NUMBER -
135 DATE - 12/10 TIME -
2:45: 0 PRESSURES i
72.64100 72.63800 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63950 RTD/S 1
81.955 2
85.326 3
83.498 4
79.038 5
80.532 6
81.060 7
81.291 S
79.299 9
79.417 10 79.488 11 79.512 12 86.057 13 86.066 14 85.954 15 90.028 16 89.862 17 89.363 IB 90.527 19 87.154 20 87.083 21 74.486 22 76.098 23 76.524 24 76.074 25 75.861 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.912 INACT 0.042 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT.
0.000 INACT 0.000 INACT 0.000
.INAC7 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.872 DEW CELLS 1
70.139 2
70.814 3
71.567 4
70.493 5
76.348 6
75.551 INACT 76.074 INACT 74.486 INACT 0.000 INACT 0.000.
INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.105 14.3786 AMBIENT PRESS
.4038819 VAPOR PRESS 72.2356L DRY PRESSURE
.2037 0
-FLOWS TOTAL FLOW 0
Page 27 of 33
Attadtment $K sENson List RECORD NUMDER -
136 DATE 12/10 TIME -
3: 0: O PRESSURES 72.64100 72.63800 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63950 ETD/S 1
81.955 2
85.326 3
83.474 4
79.061 5
80.556 6
81.860 7
81.291 8
79.346 9
79.441 10 79.488 11 79.488 12 86.057 13 86.109 14 85.997 15 90.123 16 89.838 17 89.410 18 90.551 19 87.130 20 87.059 21 74.463 22 76.098 23 76.501 24 76.074 25 75.861 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.814 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
.tNACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.875 DEW CELLS 1
70.228 2
70.615 3
71.656 4
70.482 5
76.370 6
75.529 INACT 76.074 INACT 74.463 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 c
AVG DEW CELL 73.100 14.37782 AMBIENT PRESS
.4030217
-\\
VAPOR PRESS 72.23567 DRY PRESSURE
.1757 0
FLOWS TOTAL FLOW 0
Page 28 of 33
,._ _... __ K
- " a***=**************
sENS0h LIST RECORD NUMBER - 137 DATE - 12/10 TIME -
3:15: O PRESSURE 3 72.64000 72.63700 2
1 0.00000 i
0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63850 RT*)/S 1
81.955 2
85.349 3
83.498 4
79.061 5
80.556 6
81.860 7
81.315 8
79.346 9
79.441 10 79.512 11 79.512 12 86.014 13 86.066 14 85.997 15 90.004 16 89.838 17
-89.434 18 90.551 19 87.130 20 87.035 21 74.486 22 76.098 23 76.501 24 76.098 25 75.837' 26 77.378 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.775 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.874 DEW CELLS 1
70.217 2
70.814 3
71.611 4
70.538 5
76.348 6
75.529 INACT 76.098 INACT 74.486 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.123 14.37305 AMBIENT PRESS
.4041218 VAPOR PRESS 72.23438 DRY PRESSURE
.1939 0
TLOWS TOTAL FLOW 0
1 Page 29 of 33
, K SENSOR LIsr RECORD NUMBER -
138 DATE - 12/10 TIME -
3:30: O PnEssuREs 72.64000 72.63600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESS'lRE 72.63800 RTD/S 1
82.026 2
85.373 3
83.498 4
- 79. C'8 5 5
80.579 6
81.908 7
81.339 8
79.370 9
79.465 10 79.512 11 79.512 12 86.014 13 86.109 14 85.997 15 90.171 16 89.862 17 89.482 18 90.551 19 87.106 20 87.011 21 74.463 22 76.098 23 76.501 24 76.074 25 75.861 26 77.378 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 44.727 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.884 DEW CELLS 1
70.261 2
70.792 3
71.656 4
70.593 5
76.337 6
75.574 INACT 76.074 INACT 74.463 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.146 14.36794 AMBIENT PRESS
.4044331 VAPOR PRESS 72.23357 DRY PRESSURE
.2136 0
FLOWS TOTAL FLOW 0
Page 30 of 33
. = _ -.
Attaciunent 5K 1
.'NSoR LIST RECORD NUMBER -
139 DATE - 12/10 TIME -
3:45: 0 PRESSURES 72.63900 72.63600 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63750 RTD/S 1
81.979 2
85.349 3
83.521 4
79.085 5
80.579 6
81.884 7
81.339 8
79.370 9
79.488 10 79.536 11 79.536 12 86.143 13 86.109 14 85.997 15 90.099 16 89.862 17 89.434 18 90.551 19 87.059 20 86.988 21 74.463 22 76.098 23 76.501 24 76.050 25 75.884 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INAct 0.000 INACT 44.658 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT' O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT
- 0.000 AVG RTD 79.888-DEW CELLS 1
70.316 2
70.848 3
71.633 4
70.582 5
76.359 6
75.551 INACT 76.050 INACT 74.463 INACT 0.000 INACT 0.000 INACT 0.000 IMACT G.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.158 7
14.36662 AMBIFNT PRESS
.4045982 VAPOR PRESS 72.2329 DRY PRESSURE
.0901 0
FLOWS TOTAL FLOW 0
I Page 31 of 33 l
1 I
i-l
_m.
' K SENSOR LIST RECORD NUMBER -
140 DATE - 12/10 TIME -
4: Os O PRESSURES 72.63900 72.63500 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63700 RTD/S 1
82.050 2
85.397 3
83.545 4
79.085 5-80.579 6
81.932 7
81.339 8
79.393 9
79.465 10 79.536 11 79.559 12 86.143 13 86.109 14 85.997 15 90.218 16 89.838 17-89.482 18-90.575 19 87.059 20 86.964 21 74.463 22 76.098-23 76.524 24 76.074 25 75.861 26 77.378 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 44.580 INACT 0.046 IN1.CT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.00J INACT 0.000 AVG RTD 79.896 DEW CELLS 1
70.327 2
70.770 3
71.711 4
70.682 5
76.348 6
75.529 INACT 76.074 INACT 74.463 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.162 14.3647 AMBIENT PRESS
.4046544 VAPOR PRESS-72.23235 DRY PRESSURE
.0967 0
? LOWS TOTAL = FLOW 0
Page 32 of 33
s 1 K
.********=*************
SENSOR LIST i
RECORD NUMBER -
141 DATE - 12/10 TIME -
4:15: O PRESSURES 72.63600 J
72.63500 2
1 0.00000 0.00000 INACT 1HACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.63651 RTD/S 1
82.026 2
85.397 3
83.545 4
79.132 5
80.603 6
81.932 7
81.362 8
79.370 9
79.400 10 79.559 11 79.559 12 86.143 13 86.152 34 86.040 15 90.147 16 89.814 17 89.458 18 90.575 19 87.035 20 86.940 21 74.463 22 76.121 23 76.501 24 76.074 25 75.861 26 77.378 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 44.502 INACT 0.046 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT D 000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.899 DEW CELLS 1
70 ^50 2
70.792 3
71.755 4
70.704 5
7L.370 6
75.585 INACT 76.074 INACT 74.463 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.195 14.3647 AMDIENT PRESS
.4051012 VAPOR PRESS 72.23141 DRY FRESSURE
.1132 0
FLOWS TOTAL FLOW 0
Page 33 of 33
Attachment GA TOTAL TIME WITH VERIFICATION TEST DATE 13-1991 TIME - 09:40:30 TOTAL TIME VERIFICATION GROSS GROSS NET NET TIME MASS LSF 95% UCL SCFM LSF 954 UCL 545 87616 0.0000 0.0000 5.156
-0.6369
-0.6369 600 87610 0.6593 0.0000 5.151 0.0229
-0.6364 615 87601 0.7561 0.9830 5.151 0.1196 0.3466 630 87597 0.7315 0.8928 5.14C 0.0963 0.2576 645 87590 0.7249 0.8255 5.140 0.0896 0.1902 700 87584 0.7202 0.7970 5.140 C.0849 0.1617 715 37575 0.7298 0.7896 5.146 0.0938 0.1536 730 87570 0.7261 0.7793 5.140 0.0907 0.1439 745 07563 0.7284 0.7737 5.142 0.0927 0.1383 800 S7558 0.7242 0.7662 5.142 0.0885 0.1305 815 87549 0.7289 0.7655 5.140 0.0934 0.1300 830 87543 0.7293 0.7630 5.142 0.0935 0.1271 845 87537 0.7300 0.7608 5.142 0.0941 0.1250 900 87529 0.7324 0.7607 5.140 0.0967 0.1250 915 87521 0.7368 0.7630 5.142 0.1009 0.1270 930 87514 0.7408 0.7651 5.142 0.1048 0.1291 LEAK RATE < MAX AND > MIN ALLOWED (Lo + Lam -.25 La) <=
Lc
<- (Lo + Lam +.25 La) 0.6483
<=
0.7408 <=
0.9658 Page 1 of 1 t
4 i
TOTAL TIME.- VERIFICATION TEST COOPER - DECEMBERJ 10,' 1991 -
l 1.125' TOTAL flME - LSF 3
L
.75 MAX ALLOUED i
-1.888 10TAL IIME - UCL i
i 8.875 i
i 8.7s0 t
j-6.
l I
i-
/
8.
i i.
D 8 375 i
[
v
.2sy
.if
(
~
i k
a 8.08 8.48
'8.89
'i 28 1.68 2.88 2.48 2.88 3.28 3.68 4.88
( 5:30)
.( 6:18)
( 7: 6)
( 7:54)
C 8:42)
( 9:38) i 5:38: 8 DELTA TIME IN HOURS m2C 146 - 162 E
i I
t 6-
,ep--
p... - - - - -r w---,
,.+-.--e
-3 vs--
y.
,--g
--,v-e--
---w-.-,.u.--
- ,--,-,-.<,-,,r-
,y-,
,,m,-v-w-
. C MASS POINT WITH VERIFICATION TEST DATE 13-1991 TIME - 09: 40:34 MASS POINT VERITICATION GROSS GROSS HET NET
. TIME MASS LSr 95% UCL SCFM LSF 95 UCL 530 87621.8 0.0000 0.0000 5.151
-0.6363
-0.6363 545 87616.2 0.0000 0.0000 5.156
-0.6369
-0.6369 600 87609.8 0.6595 0.0000 5.151 0.0231
-0.6364 615 87600.8 0.7607 0.9355 5.151 0.1142 0.2991 610 87596.7 0.7195 0.8178 5.140 0.0843 0.1826 vs 87589.9 0.7106 0.7699 5.140 0.0754 0.1346 700 87583.6 0.7058 0.7458 5.140 0.0705 0.1105 715 87575.4 0.7194 0.7520 5.146 0.0834 0.1160 730 87570.4-0.7144 0.7396 5.140 0.0790 0.1042 745 87562.9 0.7179 0.7380 5.142 0.0822 0.1023 800 87557.8 0.7126 0.7297 5.142 0.0769 0.0940 815 87548.9 0.7196 0.7355 5.140 0.0841 0.0999 830 87543.3 0.7202 0.7335 5.142 0,C644 0.0977 845 87536.6 0.7211 0.7325 5.142 0.0853 0.0966 900 87529.0 0.7245 0.7349 5.140 0.0888 0.0992 915 87520.9 0.7304 0.7412 5.142 0.0944 0.1052 930 87513,8 0.7353 0.7460 5.142 0.0993 0.1100
( Lo + Lam -.25 La) <=
Lc
< = ( Lo + Lam +.25 La) 0.6550
<=
0.7353 <=
0.9725 l-Page 1 of 1 l
MASS POINT - VERIFICATION TEST COOPER - DECEMBER 10,1991 1.125 MASS P0lMT - LSF
.75 MAX ALLOUED 1.988 MASS POINI - UCL 8.875 8.750 t
x o.
j f
/
8.
D 8 375 A
Y
.2
.1 l
g age i
8.08 8.48 8.88 1.28 1.68 2.88 2.48 2.88 3.28 3.68 4.88 g.
( 5:38)
(-6:18)
( 7: 6)
C 7:54)
( 8:42)
( 9:38) 5:38: 8 DELTA TIME IN HOURS REC 146 - 162 E
G
- - ~
Attadunent GE
- ea*******************
MASS Loss DATE 13-1991 TIME - 09:40:37 REC TIME CONT MASS MASS MASS NUM DELTA AIR LOSS LOSS LOSS (HOURS)
MASS INCR (1 HR)
(x 24) 146 0.00 87621.828 0.000 0.000 0.000 147 0.25 87616.195
-5.633 0.000 0.000 148 0.50 87609.789
-6.406 0.000 0.000 149 0.75 87600.820
-8.969 0.000 0.000 150 1.00 87596.680
-4.141 25.148 603.563 151 1.25 87589.930
-6.750 26.266 630.375 152 1,50 87583.586
-6.344 26.203 628.875 153 1.75 87575.430
-8.156 25.391 609.375 154 2.00 87570.414
-5.016 26.266 630.375 155 2.25 87562.891
-7.523 27,039 648.938 156 2.50 87557.773
-5.117 2S 813 619.500 157 2.75 87548.891
-8.883 26.539 636.938 158 3.00 87543.320
-5.570 27.004 650.250 159 3.25 87536.586
-6.734 26.305 631.313 160 3.50 87528.977
-7.609 28.797 691.125 161 3.75 87520,883
-8.094 28.008 672.188 162 4.00 87513.789
-7.094 29.531 708.750 r
l l
Page 1 of 1 l
l'
MEASURED MASS - VERIFICATION TEST COOPER - DECEMBER 10,1991 87.625 h x612 1
87.688 4
8 8
87.587 8
87.575
- \\
87.562 0.
l f
87.558
{
i L
87.537 N
B N
S 87.525 87.512 6
8.08 8.48-8.88 1.28 1.68 2.00 2.48 2.88 3.28 3.68 4.00
( 5:30)
( 6:18)
( 7: 6)
( 7:54)
( 8:42)
( 9:38) 5:38: 8 DELTA TIME IN HOURS REC 146 - 162 E
al
AVERAGE PRESSURE - VERIFICATION TEST COOPER - DECEMBER 10,1991 72.638 i
72.618 i
72.600 72.598 4
P 72.588
\\
S N
I 72.578 l
72.568 72.558 N
72.548 i
y i
8.00 8.48 8.88 1.28 1.68 2.88 2.48 2.88 3.28 3.68 4.08
[
( 5:30)
( 6:18)
( 7: 6)
( 7:54)
( 8:42)
( 9:38) 5:38: 8 DELTA TIME IM HOURS REC 146 - 162 E
o
AVERAGE TEMPERATURE - VERIFICATION TEST COOPER - DECEMBER 10,1991
' N.8W 79.998.
79.988 79.978 D
E 79.968 G
,O H
79.958 E
E 79.948
/
.79.938 N'
79.928 / D
~/
/A918 t
i 8.08 8.48 0.88 1.28-1.68 2.88 2.48 2.88 3.28 3.68 4.88 E.
C 5:38).
C 6:18)
( 7: 6)
( 7:54)
( 8:42)
C 9:38) j 5:38: 8 DELTA TIME IM HOURS REC 146 - 162
~
j, 1
1
, _ - ~ _ _ _ _ _ _ _. - _ _ _ - _ _ -. - _ _ _ _
AVERAGE VAPOR PRESSURE - VERIFICATION TEST COOPER - DECEMBER 10,1991 i
8.415 i
l 8.414 8.413 8.412 8.411
'/-
P 8.418 S
'7 I
8.489
/
7
\\
A/
J 8.488 r
/
/\\
/
4 8.487 Nj d 486 g
8.88 8.48 8.88 1.28 1.68 2.88 2.48 2.88 3.28 3.68 4.88 Er I
( 5:38)-
( 6:18)
( 7: 6)
( 7:54)
C 8:42)
C 9:38) il E
5:38: 8 DELTA TIME IN HOURS REC 146 - 162 1-a
I J i
i EtNIRONMENT LISTING DATE 13-1991 TIME - 09:40:59 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR NUM PRESSURE PRESSURE HUMID 1TY DENSITY VARIANCE 146 10 530 539.579 0.4067 72.2168 80.42 0.3613' O.00000 147 10 545 539.585 0.4060 72.2130 80.28 0.3612 -0.01547 148 10 600 539.581 0.4069 72.2071 80.45 0.3612 -0.02325 149 10 615 539.597 0.4077 72.2018 80.57 0.3612 -0.02127 150 10 630 539.592 0.4068 72.1977 80.41 0.3611
-0.01645 151 10 645 539.590 0.4081 72.1919 80.67 0.3611
-0.02313 132 10 700 539.592 0.4080 72.1870 80.66 0.3611
-0.01984 153 10 715 539.604 0.4086 72.1819 80.74 0.3611
-0.02036 154 10 730 539.600 0.4084 72.1771 80.70 0.3610 -0.01895 155 10 745 539.603 0.4091 72.1714 80.85 0.3610 -0.02310 156 10 800 539.606 0.4085 72.1675 80.70 0.3610 -0.01526 157 10 815 539.615 0.4096 72.1614 80.90 0.3610 -0.02444 158 10 830 539.615 0.4096 72.1569 80.91 0.3609 -0.01816 159 10 845 539.616 0.4100 72.1515 80.99 0.3609 -0.02176 160 10 900 539.022 0.4105 72.1460 81.07 0.3609 -0.02188 161 10 915 539.626
'O.4107 72.1398 81.10 0.3608 -0.02475 162 10 930 539.622 0.4110 72.1334 81.17 0.3608 -0.02542 Page 1 of 3 l
l
h Attadament 6J ee***********************
EINIROtmENT LIST 1HG DATE 13-1991 ZONE -
1 TIME - 09:41300 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR f
Ntni PRESSURE PRESSURE HUMIDITY DENSITY VAllIANCE 146 10 530 542.8C2 0.3779 72.2441 67.34 0.3592 0.00000 147 10 545 542.803 0.3557 72.2403 67.12 0.3592 -0.01498 148 10 600 542.805 0.3781 72.2339 67.37 0.3592 -0.02576 149 10 615 542.824 0.3793 72.2287 67.55 0.3592 -0.02090 150 10 630 542.817 0.3778 72.2252 67.29 0.3591 -0.01398 151 10 645 542.828 0.3799 72.2181 67.64 0.3591
-0.02823 152 10 700 542.821 0.3797 72.2133 67.61 0.3591
-0.01907
'53 10 715 542.844 0.3808 72.2002 67.77 0.3590 -0.02072 154 10 730 542.842 0.3804 72.2036 67.69 0.3590 -0.01819 155 10 745 542.851 0.3814 72.1976 67.85 0.3590 -0.02393 156 10 800 542.853 0.3804 72.1936 67.68 0.3590 -0.01630 157 10 815 542.870 0.3822 72.1868 67.95 0.3589
-0.02682 158 10- 830 542.877 0.3824 72.1826 67.97 0.3589
-0.01697 159 10 845
$42.882 0.3830 72.1770 60.07 0.3589 -0.02231 160 10 900 542.893 0.3838 72.1712 68.19 0.3588 -0.02328 161 10 91S 542.903 0.3841 72.1649 68.23 0.3588 -0.02502 162 10 930 S42.906 0.3847 72.1583 68.32
- 3587 -0.02664 1
1 Page 2 of 3
_. _... _...... J ee***********************
EINIRONMENT LISTING DATE 13-1991 ZONE - 2 TIME - 09:41:02 REC DATE TIME TEMP VAPOR CORRECT.
RELATIVE AIR PSIA /HR
}NM PRESSURE PRESSURE HUMIDITY DENSITY VARIANCE 146 10 530 535.717 0.4444 72.1806 99.75 0.3637 0.00000 147 10 545 535.728 0.4446 72.1764 99.77 0.3636 -0.01697 148 10 600 535.717 0.4445 72.1715 99.79 0.3636 -0.01971 149 10 615 535.728 0.4440 72.1662 99.01 0.3636 -0.02097 150 10 630 535.724 0.4448 72.1612 99.82 0.3636 -0.01999 151 10 645 535.709 0.4449 72.1571 99.91 0.3636 -0.01666 152 10 700 f.3 5. 720 0.4452 72.1518 99.92 0.3635 -0.02097
)~3 10 715 535.720 0.4449 72.1471 99.87 0.3635 -0.01901 154 10 730 535.713 0.4449 72.1421 99.89 0.3635 -0.02002 155 10 745 535.709 0.4454 72.1366 100.02 0.3635 -0.02194 156 10 800 535.713 0.44S1 72.1329 99.93 0.3634 -0.01468 157 10 815 535.713 0.4453 72.1276 99.99 0.3634 -0.02103 158 10 830 535.705.
0.4451 72.1229 99.96 0.3634
-0.01898 159 10 845 535.701 0.4453 72.1177 100.03 0.3634 -0.02097 160 10 900 535.701 0.4453 72.1127 100.03 0.3633 -0.02002 161 10 915 535.697 0.4454 72.1066 100.06 0.3633 -0.02432 162-10 930 535.685 0.4453 72.1007 100.08 0.3633 -0.02368 Page 3 of 3
., K
- e**e*****************
SENSOR LIST RECORD NUMBER -
146 DATE - 12/10 TIME -
5:30: O PRESSURES 72.62500 72.62200 2
1 0.00000 0.00000 TNACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.62350 i
RTD/S 1-82.050 2
85.444 3
83.617 4
79.156 5
80.650 6
82.003 7
81.410 8
79.441 1
9 79.536 10 79.607 11 79.607 12 86.229 13 86.195 14 86.083 15 90.171 26 89.838 17 89.458 18 90.598 19 86.893 20 86.869 21 74.439 22 76.074 23 76.501 24 76.050 25 75.861 26 77.354 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 47.744 INACT O.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 IllACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 i
INACT 0.000 INACT O.000 AVG RTD 79.909 i
DEW CELLS-1 70.538 2
71.069 3
71.988 4
70.848 5
76.426 6
75.518 INACT 76.050 INACT 74.439 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 l
AVG DEW CELL 73.311 14.36058 AMBIENT PRESS
.406686 VAPOR PRESS 72.21682 DRY PRESSURE
.1889 5.1506 FLOWS TOTAL FLOW 5.1506 L
l 1
Page 1 of 17
l l
Attadunent GK I
SENSOR List
- r*************
{
RECORD NUMDER -
147 DATE - 12/10 TIME -
5:45: 0 PRESbURES 1
72.61700 2
72.62100 INACT 0.00000 INACT 0.00000 INAC" 0.00000 INACT 0.00000 AVO PRESSURE 72.61900
[
RTD/S 1
82.121 2
85.468 3
83.593 4
79.180 5
80.650 6
82.003 7
81.386 8
79.441 9
79.559 10 79.503 11 79.607 32 86.143 13 86.195 14 86.126 15 90.194 16 89.8C2 17 89.434 18 90.575 19 86.916 20 86.821 21 74.439 22 76.074 23 76.501 24 76.074 25 75.861 26 77.402 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.705 INACT 0.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INAC7 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTO 79.915 DEW CELLS 1
70.516 2
70.848 3
71.855 4
70.870 5
76.448 6
75.529 INACT 76.074 INACT 74.439 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 s
AVG DEW CELL 73.265 AMDIENT PRESS 14.35994 VAPOR PRESS
.4060492 DRY PRESSURE 72.21295 TLOWS
.1576 5.1556 TOTAL FLOW 5.1556 Page 2 of 17
Attedunent 6K sENSOn List RECORD NUMBER -
148 DATE - 12/10 TJME -
6: Os O PRESSURES 72.61600 72.61200 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.61400 RTD/G 1
82.098 2
85.468 3
83.569 4
79.180 5
00.650 6
82.003 7
81.410 8
79.465 0
79.559 10 79.583 11 79.654 12 86.143 B6.195 14 86.126 15 90.171 16 89.838
+
89.482 18 90.598 19 86.893 20 86.798 zI 74.439 22 76.098 23 76.501 24 76.050 25 75.837 26 77.354 INACT 0.000
.INACT 0.000 INACT
-0.000 INACT 0.000 INACT 47.617 INACT O.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.911 DEW CELLS 1
70.493 2
71.146 3
71.999 4
70.859 5
76.437 6
75.529 INACT 76.050 INACT 74.439 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.324 14.35959 AMBIENT PRESS
.4068597 VAPOR PRESS 72.20714 DRY PRESSURE
.0918 5.1506 FLOWS TOTAL FLOW 5.1506 Page 3 of 17
Att:clunent 6K SENSOR LIST RECORD IJUMBER -
149 DATE - 12/10 TIME -
6:15: O PRESSURES 72.61100 72.60800 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 P
INACT AVG PRESSURE 72.60950 RTD/S 1
82.093 2
85.492 3
83.617 4
79.204 5
80.674 6
82.026 7
81.433 8
79.441 9
79.583 10 79.631 11 79.654 12 86.229 13 86.238 14 86.126 15 90.242 16 89.909
.1'7 89.458 18 90.551 19 86.845 20 86.774 21 74.463 22 76.074 23 76.501 24 76.074 25 75.861 26 77.378 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 47.598 INACT 0.049 INACT 0.000
- NACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT O.000 INACT 0.000 IN?.OT O.000 INACT O.000 INACT 0.000
'INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG RTD 79.927 DEW CELLS 1
70.582 2
71.368 3
72.010 4
70.903 5
76.492 6
75.507 INACT 76.074 INACT 74.463 INACT 0.000-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.384-14.35959 AMBIENT PRESS
.4076788
. VAPOR PRESS 72.20182 DRY PRESSURS
.2103 5.1506 TLOWS l
TOTAL FLOW 5.1506 l
Page 4 of 17 o
?
. K cv
.+.at****************
SENSOR LIST RECORD NUMBER - '150 DATE - 12/10 TIME -
6:30: O PRESSURES 72.60600 72.60300 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT
'INACT AVG PRESSURE 72.60450 RTD/S 1
82.098 2
85.492 3
83.640 4
79.204 5
80.674 6
82.003 7
81.433 8
79.437 9
79.559 10 79 631 11 79.654 32 86.229 13 86.238 14 86.126 15 90.19, 16 89.862 17 89.410 18 90.598 19 86.'45 20 86.750 21 74.439 22 76.074 23 76 Sci 24 76.074 25 75.861 26 77.378 Int"Y 0.
INACT 0.000 INACT-0.000 INACT-0.000 i v.C.' 47.510 INACT 0.049 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INAC7 0.000 INACT 0.000 INACT:
0.000 AVG RTD 79.922 DEW CELLS 1
70.615 2
70.814 3
72.054 4
70.969 5
76.481 6
75.518 INACT 76.074 IWACT 74.439 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.319 14.35959 AMBIENT PRESS VAPOR PRESS
.4067951 72.19771 DRY PRESSURE
.2037 5.1404 PLOWS TOTAL PLOW 5.1404 Page 5 of 17
~
, K i
- s*******************
SENSOR LIST RECORD NUMBER -
151 DATE - 12/10 TIME -
6:45: O PRESSURES
~
72.60200 72.59800 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVO PRESSURE 72.60000
-.RTD/S 1
82.121' 2
85.516 3
83.617 4
79.227 5
80.696 6
82.050 7
81.457 8
79.441 9
79.583
'10 79.607 11 79.678 12 86.229
- 13 86.238 14 86.126 15 90.194 16 89.862 17 89.404 18-90.575 19 86.821 20 86.750 21 74.415 22 76.050 23 76.501 24 76.074 25 75.837 26 77.354 INACT 0.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT 47.422 INACT 0.049 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000
-INACT 0.000 INACT O.000 INACT 0.000 INACT O.000 INACT 0.000
.INACT 0.000 INACT
-0.00G INACT 0.000 INACT 0.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT-0.000
.INACT 0.000 AVG RTD 79.920 DEW CELLS 1
70.682 2
71.324 3
72.054 4
70.992 5
76.503 6
75.518 INACT 76.074 INACT 74.415 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT.
0.000 INACT 0.000 INACT 0.000
. AVG DEW CELL.
73.413 14.3593 AMBIENT. PRESS-
.4080717 VAPOR PRESS' 72.19193
-DRY PRESSURE
.212 5.1404 FLOWS
--TOTAL FLOW-5.1404 l'
-Page 6 of 17
. - K i'.NSOR LIST RECORD NUMBER -
152 DATE - 12/10 TIME -
7: 0: O PRESSURES 72.59700 72.59300 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.59500 RTD/S 1
82.098 2
85.516 3
83.664 4
79.204 5
80.698 6
82.050 7
81.457 8
79.441 9
79.583 10 79.631 11 79.678 12 86.143 13 86.238 14 86.126 15 90.194 16 89.814 17 89.482 18 90.598 19 86.798 20 86.726 21
=74.439 22 76.074 23 76.501 24 76.074 25 75.837 26 77.378 INACT 0.000 INACT O 000 INACT 0.000 INACT 0.000 INACT 47.354 INACT 0.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.922 DEW CELLS 1
70.648 2
71.268 3
72.054 4
71.025 5
76.514 6
75.540 INACT 76.074 INACT 74.439 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
. AVG DEW CELL.
73.410 14.36023 AMBIENT PRESS
.4080375 VAPOR' PRESS 72.18697 DRY PRESSURE
.1428 5.1404 FLOWS TOTAL FLOW 5.1404 Page 7 of 17
. K SENSOR LIST RECORD NUMBER -
153 DATE - 12/10 TIME -
7:15: O PRESSURES 72.59200 72.58900 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.59050 RTD/S 1
82.145 2
85.516 3
83.688 4
79.227 5
80.722 6
82.050 7
81.481 8
79.465 9-79.607 10 79.621 11 79.678 12 86.316 13 85.238-14 136.165 15 90.242 16 89.838 17 89.458 18 90.551 19 86.774 20 86.703 21 74.463' 22 76.074 23 76.501 24 76.074 25-75.837 26 77.354 INACT 0.000 INACT 0.000 INACT 0.00C
'INACT 0.000 IFACT 47.305 INACT 0.049 INACT 0.000 INACT 0.000
- 1. <.CT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT-
- 0. 0')0 INACT 0.000 INACT 0.000 INACT 0.009 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.934 DEV-CELLS 1
YO.748 2
71.423 3
72.098 4
71.080 5
7t'.481 6
75.540 INACT 76.074 INACT 74.463 INA CT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 IN'sCT 0.000 INACT 0.000 INACT 0.000 LVG DEW CELL 73.453 14.3593 AMBIENT PRESS VAPOR PRESS
.4086241
'i'2.18188 DRY PRESSURE 0
5.1455 FLOWS TOTAL FLOW 5.1455 l-(
Page 3 of 17 l
l
h K SENSOR LIST RECORD NUMBER -
154 DATE - 12/10 TIME -
7:30: O PRESSURES 72.58700 72.58400 2
1 0.00000 0.00000 INACT INACT-0.00000 0.00000 INACT INACT AVG PRESSURE 72.58549
-RTD/S 1
82.145' 2
85.563 3
83.640 4
79.251 5
80.722 6
82.050 7
81.457 8
79.488 9
79.583 10 79.607 11 79.678 12 86.229 13 86.281 14 86.211 15 90.266 16 89.862 17 89.434 18 90.575 19 86.750 20 86.679 21 74.439 22 76.050 23 76.501 24 76.074 25 75.837 26 77.354 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000-INACT 47.256 INACT 0.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT
-0.000-INACT-0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 t
AVG RTD 79.930 DEW CELLS 1
70.759 2
71.169 3
72.220 4
71.069 5
76.514 6
75.507 INACT 76.074 INACT 74.439 INACT 0.000-INAC1 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.434 14.35704 AMBIENT PRESS
.4083592 VAPOR PRESS 72.17714 DRY PRESSURE
.151 5.1404 FLOWS TOTAL FLOW 5.1404 Page 9 of 17
= _
, - ~
- K SENSOR LIST RECORD NUMBER -
155 DATE - 12/10 TIME -
7:45: O PRESSURES 72.58200 72.57900 2 --
1 0.00000 0.00000' INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.58051 RTD/S 1
82.216 2
85.516 3
83.711 4
79.251 5
80.722 6
82.074 7
81.481 8
79.465 9-79.631 10 79.678 11 79.702 12 86.229 13 86.281 14 86.211-15 90.147 16 89.838 17 89.410 18 90.575 19 86.726 20 86.679 21 74.415 22 76.074 23 76.501 24 76.050 25 75.837 26 77.354 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 47.188 INACT 0.052 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000
-INACT 0.000 AVG RTD 79.933 DEW CELLS 1
70.792 2
71.456 3
72.143 4
71.124 5
76.525 6
75.563 INACT 76.050 INACT 74.415 INACT 0.000 INACT 0.000-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.491 14.3564 AMBIENT PRESS VAPOR PRESS
--.4091394 72.17136 DRY PRESSURE FLOWS
.0819-5.1421 TOTAL FLOW 5.1421 Page 10 of 17
_.. _ _ _... K SENSOR LIST RECORD NOMBER -
156 DATE - 12/30 TIME -
8: 0: O PRESSURES 72.57800 72.57400 2
1 0.00000 0.00000 INACT INACT 0.00000 0.00000 INACT INACT AVG PRESSURE 72.37600 RTD/S 1
82.145 2
d5.563 3
83.688 4
79.251 5
80.722 6
82.098 7
81.505 8
79.488 9
79.607 10 79.676 11 79.702 12 86.273 13 86.281 34 86.168 15 90.218 16 89.836 17 89.434 1C 90.575 19 86.726 20 86.655 21 74.439 22 76.050 23 76.501 24 76.074 25 75.837 26 77.354 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.158 INACT 0.049 IMACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
.INACT 0.000 AVG RTD 79.936.
DEW CELLS 1
70.770 2
71.158 3
72.198 4
71.124 5
76.525 6
75.518 INACT 76.074 INACT 74.439 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.441 14.35611 AMBIENT PRESS VAPOR PRESS
.4084577 DRY PRESSURE
- 72.16755
.1741 5.1421 FLOWS TOTAL FLOW 5.1421 1
Page 11 of 17
)
~Q.
Attaclunent 6K SENSOR LIST RECORD NU'4BER -
157 DATE - 12/10 TIME -
8:15: O PRESSURES 72.57300 72.56900-2 1
0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.57100 RTD/$
1 82.216 2
85.587 3
83.711 4
79.275 5
80.745 6
82.121 7
81.505 8
79.536 9
79.631 10 79.678 11 79.726 12 86.273 13 86.324 14 86.254 15 90.028 16 89.838 17 89.482 18 90.575 19 86.703 20 86.631 21 74.439 22 76.074 23 76.501 24 76.050 25 75.837 26 77.354 INACT 0.000 INACT 0.000 INACT O.000 INACT.
0.000.
INACT 47.129 INACT-0.049 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.945' DEW CELLS 1
70.837 2
71.512 3
72.220 4
71.191 5
76.536 6
75.540 INACT 76.050 INACT 74.439 INACT 0.000 INACT O.000 INACT-0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 AVG DEW CELL 73.522 AMBIENT PRESS -
14.35449-
-.4095604 VAPOR PRESS DRY PRESSURE
- 72.16144
.2021 5.1404 FLOWS
. TOTAL FLOW.
5.1404 Page 12 of 17
den's+4e p ersHus@
+ K i
~
SENSOR LIST KECORD NUMBER -
158 DATE - 12/10 TIME -
8:30: O PRESSURES 72.56800 72.56500 2
1 0.00000 INACT -
0.00000 INACT 0.00000 0.00000 INACT INACT AVGEPRESSURE 72.56650 RTD/S 1
.82.193 2
85.587 3
83.735 4
79.299 5
80.769 6
82.098 7
81.505 8
79.488 9
79.654 10 79.702 11
".).726 12 86.316 13 86.324 14 86.211 15 90.194 16 89.862 17 89.434 18 90.598 19 86.679 20 86.631 21 74.415 22 76.027 23 76.501 24 76.074 25
.75.837 26 77.354 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.031 INACT 0.052 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000
.INACT
.0.000 INACT 0.000 AVG RTD 79.945 DEW CELLS 1
70.814 2
71.512 3
72.320 4
71.180 5
76.548 6
75.496 INACT 76.074 INACT 74.415 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.525 AMBIENT PRESS -
14.35385
.4096019-VAPOR-PRESS DRf PRESSURE
- 72.1569
.2186-5.1421 TLOWS TOTAL FLOW 5.1421 Page 13 of 17
Athudunent GK -
- * * * * * * * * * * * * * ~ * * * * * * * *
- SENSOR LIST RECORD NUMBER -
159 DATE - 12/10 TIME -
8:45: O PRESSURES 72.56300 72.56000 2
1 0.00000 0.00000 INACT INACT 0.00000
'INACT -
0.00000 INACT AVG PRESSURE 72.56150 RTD/S 1
82.169 2
85.610 3
83.711 4
79.299 5
20.769 6
82.098 7
81.528 8
79.536 9
79.654 10 79.678 11 79.749 12 86.359 13 86.324 14 86.211 15 90.171 16 89.838 17 89.482 18 90.598 19 86.679 20 86.608 21 74.415 22 76.050 23 76.477 24 76.050 25 75.837 26 77.354 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 47.012 INACT 0.049 INACT 0.000 INACT O.000 INACT O.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0 000 AVG RT3 79.946 DEW CELLS 1
70.859 2
71.567 3
72.353 4
71.224
.5 76.548 6
75.529 INACT 76.050 INAUT 74.415 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 AVG DE% CELL 73.556 14.35227 AMBIENT PRESS VAPOR PRESS
.4100384 DRY PRESSURE
- 72.15146
.1988 5.1421 FLOWS TOTAL FLOW 5.1421 Iage 14 of 17
_m._
. K SENSOR LIST
-RECORD NUMBER -
160 D/.TE - 12/10 TIME -
9: 0: O PRESSURES 72.55800 72.55500 2
1 0.00000 0.00000 INACT INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.55650 RTD/S 1
82.240 2
85.587 3
83.735 4
79.299 5
80.793 6
82.121 7
81.552 8
79.536 9
79.654 10 79.678 11 79.773 12 86.402 13 86.367 14 86.254 15 90.147 16 89.814 17 89.410 18 90.598 19 86.6$5 20 85.584 21 74.391 22 76.050 23 76.501 24 76.074 c 25
-75.837 26 77.330 INACT 0.000 INACT 0.000 INACT 0.000
'INACT 0.000 INACT 46.914
-INACT 0.052 IN1.CT O.000 INACT O.000 INACT
'O.000 INACT 0.000 INACT' O.000 INACT 0.000 INACT 0.000 INACT O.000
-INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD 79.952
. DEW CELLS 1
70.925 2
71.622 3
72.419 4
71.290 5
76.559 6
75.518 INACT -76.074 INACT 74.391 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL
'73.591 14.35095 AMBIENT PRESS VAPOR PRESS
.4105169 72.14599 DRY PRESSURE 1 FLOWS
.1889' 5.1404 TOTAL FLOW 5.1404 Page 15 of 17 l
i
4R.
.u ua.-
.:h.a w
Attoclunent 6K SENSOR LIST RECORD NUMBER.-
161 DATE - 12/10 TIME -
9:15: O PRESSURES' 72.54900 2 -
72.5S200 1-0.00000 0.00000 INACT INACT 0.00000 INACT 0.00000 INACT AVG PRESSURE 72.55051 RTD/S 1
82.240 2
85.634 3
83.711 4
79.322 5
80.793 6
82.145 7
81.552 8
79.536 9
79.678 10 79.702 11 79.749 32 86.402 13 86.367 14 86.254 15 90.194 16 89.862 17 89.458 18 90.598 19 86.655 20 85.581 21 74.415 22 76.027 23 76.477 24 76.074 25 75.813 26 77.354 INACT 0.000 INACT 0.000 INACT-0.000 INACT r.000 INACT 46.895 INACT 0.052 INACT 0.000 INACT O.000 INACT 0.000 INACT 04000 INACT 0.000
-INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG RTD
-79.956
= DEW CELLS 1
70.980 2
71.700 3
72.353 4
71.301 5
76.548 6
75.540 INACT 76.074 INACT 74.415
.INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 AVG DEW CELL 73.605 AMBIENT PRESS 14.35321 VAPOR PRESS
.4107034 DRY PRESSURE 72.1398
.1494 5.1421 FLOWS TOTAL PLOW 5.1421 Page 16 of 17
. K a**********************
SENSOR LIST RECORD NUMBER 162
.DATE - 12/10 TIME -
9:30: O PRESSURES 1
72.54300 2
72.54600 0.00000 INACT 0.00000 INACT 0.00000 INACT -
0.00000 INACT AVG PRESSURE 72.54449 RTD/S 1
82.216 2
85.634 3
83.735 4
79.322
+
5 80.793 6
82.145 7
81.552 8
79.559
-9 79.654 10 79.702 11 79.773 12 86.445 13 86.367 14 86.254 15 90.218 16 89.838 17 89.434 18 90.598 19 86.631 20 86.584 21 74.391 22 76.027 23 76.477 24 76.050 25 75.813 26 77.330 INACT 0.000 INACT 0.00^
INACT 0.000 INACT 0.000 INACT 46.797 INACT 0.05z INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT' O.000 INACT~
0.000 INACT O.000 INACT 0.000 INACT 0.000 INACT 0.000.
INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 INA CT 0.000 AVG RTD 79.952 DEW CELLS 1
71.014 2
71.777 3
72.4I9 4
71.313 5
76.559 6
75.518 INACT-76.050 INACT 74.391 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT 0.000 INACT O.000 INACT 0.000 AVG DEW CELL 73.630
-14.35483 AMBIENT PRESS VAPOR PRESS
.4110493 72.13345 DRY PREESURE
.1181 5.1421 FLOWS TOTAL FLOW 5.1421 Page 17 of 17 A
TYPE A TEST RESULTS AS LEFT AS FOUND
% Weight / Day
% Weight / Day TOTAL TIME 0.17103 0.17103
- Least Squares Fit Leak Rate (LJ 0.19507 0.19507 95% UCL Leak Rate 0.01094 0.3322. 6 LLRT (Type B & C) Adjustments 0.11052 0.38581 Other Adjustments (Drywell Vent Monitor) 0.31653 0.91314 Total (Lines 2,3, & 4) 0.17768 MASS POINT 0.17768 I.xast Squares Fit Leak Rate (L.)
0.18013 0.18013 95% UCL Leak Rate 0.01094 0.33226 LLRT (Type B & C) Adjustments 0.11052 0.38581 Other Adjustmenes (Drywell Vent Monitor) 0.30159 0.8982 Total (Lines 2,3, & 4)
I Page 1 of 1
_,. -- aw
.n._.g..
'is
)
Attcchment 7B g
VERIFICATION TEST RESULTS TOTAL TIME Superimposed Leakage Rate (L,)
.636 % Wt/ Day 3
- LSF Leak Rate - Type A Test (L,,)
.1710 % Wt/ Day
.25 1
.15875 % Wt/ Day 3
LSF Leak Rate During Verification Test (I ).
.7408 % Wt/ Day s
1
(( + L.,;.25 L.) $ 14 -5 (I, + L, +.25 L.)
l(.636 +.1710 -.15875) 5 7408 5 (.636 +.1710 +.15875)
.6483J5 7408 3 9658 MASS POINT Superimposed Leakage Rate (L,)
.636 % Wr/ Day 1
JLSF Leak Rate - Type A Test (L,.)
.1776 % Wt/ Day
.25 L.-
.15875 % Wt/ Day-i i;LSF Leak Rate' During Verification Test (LJ
.7353 % Wt/ Day; (1, + L,
.25 L ) 5 7353 5 (L, + L., +.25 L )
.(.636 + 1776.15875) s.7353 5 (.636 +.1776 +.15875)
.6550 5 7353 5 9725 Page 1 of 1
{
ne
+
e s.-,
y 3
' ittachment 8Al [y' 1989 1991 LLRT DATA TYPE C; PEN NO. DESCRIPTION -
-1991 1991 1990 1990 1989.
1989 AS FOUND AS LEFT 'AS FOUND AS LEFT AS FOUND AS LEFT -
X-7A
.MSIV Line A 0.83-
'O.83
.0.0765.
0.0765 6.68:
'237 c
.X-7B -
MSIV - Line B-
- 0.45-0.45.-
0.1145 0.1145 5.75 0.84
' X-7C MSIV - Line C 2.08 2.08
'0.59 0.59 4.81 1.59 X-7D L MSIV.- Line D -
0.239 0.239 3345 3345' 3.08 0
X-8 Main Steam Lines Drain
~ 4.22 4.22' 5.74 0.65 8.01' 2.76 X-9A Rx FW Check Line A - Inb 5.4 0.46 63.5 0.92 9.53 0
. X-9A Rx FW Chk. Line A - Outb 600.
1.04 3033 7.7 32.65 0
X-9B
.Rx FW Check Line B - Inb
- 600 4.8
.27.7 1.58 13 13 X-9B Rx FW Chk. Line B - Outb 4i5 0.655 600 4.6 108.03 0
X-10 RCIC Turbine Steam Supply 0.225 1.69-0.76 0.76 034 5.54 X-11 HPCI Turbine Steam' Supply. 2.125 -
4.225 2375 2375 4.15 4.15 X-12 RHR Shutdown Cooling 53 4.95 1.85 2.45 5.94 5.45 System X-13A RHR Loop A Injection 4.43:
4.43 4.775 4.775 24.25 8.73 X-13B RHR Loop B Injection 4.08' O.495 0.2 10
.12.82 12.82 X-14 RWCU Supply 79.2 0.136 4.85 033 2.42 2.42 X-16A' CS Loop A Injection
' O.08 0.0
'O.05 0.05 0'
0 X-16B CS Loop B Injection' O.655 1.0
'0 0
0.28 0.28
. Page 1 of 8
.3 s
- ' Attaclunent 8A.
1989 - 1991 LLRT DATA TYPE C.
PEN NO. L DESCRIPTION
- 1991 1991 1996
- 1990 1989 1989 AS FOUND AS LEFT AS FOUND AS LEFT ' AS FOUND AS LEFT
'X-18 Drywell Equip Drain Sump.
0.1275 0.1275 0.014 038
. 0.84 0.84-Disch X-19
. Drfwell Floor Drain Sump..
0.0275-
.0.0275 0.034 0.65 0.53 0.53
~
Disch '
i X-25
- Drywell Purge & Vent 1.6.
1.6 '
0.1 1.625 335
'O X-25
! SBNI :
0.0075 0.0075 0.004 0.006 0-0.01 X Drywell Purge & Vent 0.145 0.145:
0.1 6.75 0
236-Exhaust X-37C CRD Mini Purge to Rx' O-0.0002' 5.1-0.081 0
0 Pump A X-38C CRD. Mini-Purge to Rx 0.001..
0.0002 -
'036 036 0
0 X-39A e Spray -Loop A 2.175.
1.465 1395 1395 0.7
- 0.7 X-39B Drywell Spray -Loop B '
0.56 0.1875 0
0-131 131 X-39B L SBNI System B to Drywell 0.005 0.P W 0.003 0.29 0.05 0.02 X-41
) Rx Water Sample 0.0015 0.0015 0.0095 0.0095 0
0-X-42 SLC Injection 0.01 0.01 0.002 0.002 0
0 X-205-Torus Purge & Vent Supply 1.75 1.75 2.185 23 25.81 0.71 X-205 Torus Vacuum Relief 3.62.
1.905 2.0'2 2.02 4.6 1.21 X-205 Torus Vacuum Relief 2.5 1.59 1.52 1.52 2.6 2.57 Page 2 of 8 6
+
4
--w, e
3-r
'e y
' Attachment 8A 1989 - 1991 LLRT DATA TYPE C--
PEN NO. DESCRIPTION 1991 1991-
'1990 1990' 1989
' 1989 AS FOUND AS LEFT -AS FOUND AS LEFT AS FOUND : AS LEFT
- X-205 SBNI System A to Torus 0.035 0.035 0.011 0.52 0.01 0.01 X-210A
' RCIC Minimum Flow.
0.485 0.89 0.0215 0.0215 1.12.
1.12 X-210A.
RHR Hx A Drain to TomsL.
0 0
0 0-0 0
X-210A RHR Loop A' Minimum -
0 0
0.095 0.095 0.09 0.83 Flow X-210B HPCI Minimum Flow 0.735 0.68
-0.68 0.68 0.17
. 0.17 X-210B '
RHR Hx B Drain to Torus -
3.85 3.85 0.72 0.55-0.25 0.02 X-210B RHR Loop B Minimum -
0.46 0345 12.1 0
0 0.69 Flow X-210A RHR Loop A to Torus 0.1 7.56
. 0.425 335 0
136 X-211 A'
. X-210B RHR Loop B to Torus 3.225 7.1 0.455 1.7 4.69 4.69 X-2113 X-211B SBNI System B to. Torus
. 0.001 0.001 0.004 0.026 0
0
.-f X-212 RCIC Turbine Exhaust 3.76-6.17 0.855 2.25 11.88 11.88 X-214 HPCI Turbine Exhaust 6.6 6.6 2.715 1.635 139 139 X-214 RHR Hx A Vent 0.003 0.003 0.16 0.16 0.07 0
X-214 RHR Hx B Vent-0.0005-0.0005 1.15 0.005 0.01 0
X-214
. HPCI Turbine Exhaust Drain L 0375 0.0115 2.265 0.195 0.01 0.01 I
Page 3 of 8 -
s t
. i
.~.
m.
1
- 73,r
" Attachment 8Al'~
I i
1989 - 1991 LLRT DATA TYPE C
- PEN NO.
DESCRH"flON
-1991
- 1991'-
1990 1990-1989 1989 AS FOUND AS LEFT AS FOUND -
AS LEFT AS FOUND - AS LEFT X-220 Torus Purge & Vent Exhaust 0.38 1.07
'2.8 1.465 4.76 1.83-X-221 RCIC Vac Pump Disch to 1.52 0.53 1.0 1.51 1.27 1.27 Torus X-222' HPCI Turbine Dmin to
- 0.002 0.002 0.0105 0.0105 0.03
'O.03 Torus X-223A CS Loop A Test 63 0.57 2.26 2.26 0
0-X-223A CS Loop A Minimum Flow '
O.02'
- 0.0 1.85 1.85 0.24 0.24 X-223B CS.. Loop B Test 032L 0.0 0
3.2 0.51 0.51 X-223B CS B Minimum Flow 0.25.'
- 0.5 12.5 0
0.4 0.4 X-224.
RCIC Suction '
2.54 0.132 0.14 0.14 0.26 0.26 X-225A RHR Pump. A Suction 1.55-
' 4.2 2.89 2.89 0
1.71 X.-225B RHR Pump C Suction' 2.08
- 2.08 6.24 6.24' 4.93 1.15 X-225C RHR Pump B Suction.
2.52 0
0.74 9.8 3.0 3.0 X-225D RHR Pump D Suction 7.46 7.46 0.5 0.66 134 134 X-226 HPCI Suction -
13.4 0338 0
0 25.71 2.8 X-227A CS Imop A Suction -
0 0054 1.05 1.05 231 231 X-227B.
CS Imop B Suction 1.23 0
. 0.1 0.1 0.52 0.52 Page 4 of 8 4
g
a.
I
, Attachment 8A 1989 - 1991 LLRT DATA TYPE B PEN NO.
DESCRIPTION-
'.1991;
.1991 1990' 1990 1989'
.1989-AS FOUND. AS LEFT AS FOUND AS LEFT
X-1A NE Drywell. Equip Hatch 0-0 0
0
.0 0
X-1B SW Drywell Equip Hatch.
0'
'O O
O 0
0 X-21 Drywell Airlock -
10.47 8.676
.10
.3.42 0.
0.1 i
X-4 Drywell Head Access Hatch
'0 0
0 0-0 0
X-6 CRD Removal Hatch 0
0.08 0.046 0
0 0
X-7A MS Line A Expansion 0.0361 0.0361 0'
O 038 038 Bellows X-7B MS Line B Expansion ~
.0.1801 0.1801 0.2 0.2 0.44 0.44
. Bellows X-7C MS Line C Expansion 0.1291 0.1291 0.33 033 035 035 Bellows X-7D MS Line D Expansion 0.6 0.6 036 036 0.15 0.15 l
Bellows X-9A RF Line A-Expansion 0.03 0.03 0.11 0.11 0.03 0.03 Bellows X-9B
. RF Line B Expansion 0.03 0.03 0.06 0.06 0
0 i
0 0
0 0
0 X-35B TIP A' 0
0 0
0 0
0 X-35C TIP C-0 0
0.003 0.003 0
0 Page 5 of 8 1
.4 m
.u'
- c.
w e
558 8
8 B
gO O O O dd d O O OO d O 6 O O O d O
-3.) :
e o
O 85$
S 8
O O O O d d d'O O O O d O 6 O O O d 2
m 4
n f
s s
a a
x M
.O O O O d O M O O O O d O d O b O O o'
Z-D.
N
'4-
- O-o p-E w-8 m
m g
S O
=
m-e Q
M4 O O O O.d O M C O O O d O d O M C C pog se a
a w"w e
m w -- > : $ M.
g9N.
,.9 mRC. O O O O O " O O O O 'O O O O O
.O O
M.
g Z
ch D
00-O
'A
.N
-g m 8g m M 4~O -O O O O d M C CO O O O O O O O O m
m m
m 3:g y 3
=
c c-c a
ea u
.6^6 6 6 6
a ;S "6 uN *l5 5
.a W
- u g4 g-g e n.e e S.=g y ) e' y e 4 4 4 g
g 5
g9 g 9 9 s z. 8 g; g 2 -g 2 2 g2 g
~
a a
- a. g
=
8-2 a..a > 2 > >
a>
a-i, (. s -s Es s 3 j j -s s '!- g E ! s ! s p p a! $-.! 6. a g 9-a 1 g 1.1 ca 1 a-g a 2 -
- a -a a 315 Z 3 3 2 z 2 2 3 2.3 m
6
<-m a ox<m oom a z-MBlMR$-@888885555558 zm 99 7 i 9 7 7
- - 7 7
A-X X X-X X X X X X X X X X X X X X-X b
u-
1 g
i' ;
A.
8 tn i
m h.ca T
'tt F
A.
E 9L 8
2 1
1 9 S 1
0 0
1A 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DNUO 9F 8
2 1
1 9 S 1
0 0
1 A 0 0 0'
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T
.FE 0L 8
7 7
7 3
9 3
8 1
1 8
9 S 1
0 0
0 0
1A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DN U
A O
T 0F 8
7 7
3 A
9 3
8 1
8 9 S 1
0 0
0 8
D 1A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o
f
. T
.R B
T 7
F e
-L E
a E
g L.P 1L 7
P 9
0 1.Y 9 S 0
0 1A 9 T 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9
1 D
N 9
U 8
O 9
1F 7
1 99 S 0
6 0
1 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
l l
l l
1 2 3 4 5 o
o o
o r
r r
r h
r r
r r
r t
t t
t t
t t
t t
r c h o
o o
o o
n n
n n
e t
o o
o o
w a
c P P P P P t
g C C C C r
o g r H a
n n
n n
n n
e P n
e H
e s
g o
o o
o o i& & & &
w w
. n t
t t
t t
N i i i i i i
r s
s o
o e
r g o o
e s
a c
c c
c c
t n
n n
n P O
P c e
l e
e e
e e
t o
o o
o a i c
c F d p p p p p i
I n
t n
e A c
a i i i i e
l T
o s
's s
s s
t t
t t
a a
a a g o o
g A
n e n
n n n
n P'
M t
t t
t a V M I
I I
I I
a s
ia H n
n n
n t
I t
u s
r r
r r
r r
R' n
l l
e e
e e
o m
n o
r u D l
e e
e e
e C
o m
m m
mV o
r l
z z
z z
z u
o V T o
e i i i i i r
mru u
u r
s l
l l
l l
T u
wiiiii S
t i
t r
r wd u wW u
t t
t t
b b b b b E'
e s
s s
s r
y e
e o
I I
I I
L MN oN E o
r a
a a
a a
D N
n n
n n
t t
t t
t I
S T D S S S S S O^
N' A B D E A D A B B 3 4 4 4 4 5 5 6 0 0 0 3 H
N 0 0 0 0 0 0 0 0 3 0 0 1
1 2 3 4 5 1
1 1
1 1
1 1
1 2 2 2 2-WP P P P P F
P' X X X X X X X X X-X X X D S S S S S I
I I
I I
~
x
! Attachment 8A 1989 - 1991 LLRT DATA.
TYPE B" PEN NO.. ' DESCRIIrrIO -
1991:
1991 1990 1990
'1989-1989
-AS FOUND AS LEFT : AS FOUND AS'LEFT AS FOUND' AS LEFT SIP 6 Stabilizer Inspection Port 6.;
01 0
0.
0-0 0
~ >
SIP 7' S.tabilizer Inspection Port 7.
0 0
0 0
0 0
SIP 8-
- Stabilizer Inspection Port 8 0
0 0
0
.0 0
X-25 Testable Flange 0
'0 0
0 Inactive
- Inactive -
X-26 Testable Flange -
'O O
O O
Inactive Inactive.
X-205 Testable Flange -
0 0
0 0
Inactive
' Inactive -
X-2.05 Testable Flange 0
0 0
.' O
. Inactive
. Inactive '
+
X-220 Testable Flange 0
0 0
0 Inactive Inactive
,j 3
Totals 236.1148 99.1093 156.5427 88.0912 114.23 56.45 I
Page 8 of 8 A
m.
.. B 1991 LLRT ADJUSTMENTS TO ILRT PEN NO.
AS FOUND AS LEFT DIFFERENCE MIN PATII MIN. PATII SCFII
~ SCFII-SCFII X-9A
- 5.4 0.46 X-9B.
45.5_
0.655 X-12 5.3 -
4.95 X-13B 4.08 0.495 4
- X-14 79.2 0.1335 X-16A :
0.08 0
X-38C 0.001 0.0002 X-39A
.2.175 1.465 X-39B 0.56 0.1875 X 41-0.0015 0
X-205 3.62
-1.905
' X-205 2.5 1.59 3
- X-210B 0.735 0.68 6'
X-210B 0.46 0.345 X-221 1.52 0.53 X-223A 6.3 0.57
- X-223A' O.02 0
X-223B 1.
- 0.32 -
0
- X-224 '
2.54 0.132 X-225C.
2.52 0
X-226'-
13.4 0.338
.X-227B -
1.23
'0 X-2 :
10.47 8.676
- SIP-3 0.16-0
. X-214 -
0.375 0.0115 TOTAL
-188.4675 23.1237 165.3438 Page 1 of 1
- - _