Forwards Proprietary & Nonproprietary Vols 1 & 2 of RESAR-SP/90 Westinghouse Advanced Pwr,Module 5, Reactor Sys. Proprietary Rept Withheld (Ref 10CFR2.790)
ML20094D159
Person / Time
Site: 05000601
Issue date: 07/31/1984
From: Rahe E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Harold Denton, Eccleston K
Office of Nuclear Reactor Regulation
Shared Package
ML19273A435 List:
References
NS-EPR-2944, NUDOCS 8408080278
Download: ML20094D159 (2)


Text

~

F m j <

Ba 355 Westinghouse Water Reactor Pittsburgh Pemsylvania15230 Electric Corporation Divisions NS-EPR-2944 July 31,1984 Pr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Docket No STN-50-601 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 SJBJECT: Westinghouse Advanced Pressurized Water Reactor (MAPWR) Reference Safety Analysis Report, RESAR-SP/CO , PDA Module 5, " Reactor System" (Voltrnes 1 and 2)

ATTENTION : K. T. Eccleston, Project Manager, SSFB

Dear Mr. Denton:

Enclosed are:

1. Forty-one (41) copies of a Westinghouse document entitled, Westinghouse Advanced Pressurized Water Reactor RESAR-SP/90, PDA Module 5, " Reactor System" (Voltmes 1 and 2) (Proprietary).
2. Four (4) copies of a Westinghouse doctznent entitled, Westinghouse Advanced Pressurized Water Reactor RESAR-SP/90, PDA Module 5, " Reactor System" (Voltrnes 1 and 2) (Non-Proprietary).
3. One (1) copy of an Application for Withholding Proprietary Information From Public Disclosure, AW-84-77 (Non-Proprietary) .
4. One (1) copy of an original affidavit, AW-82-57 (Non-Proprietary).

The enclosed document; RAIMR RESAR-SP/90, PDA Module 5, "Reacter System",

(Volumes 1 and 2); is the fif th in a series of modular PDA doctznents planned for sutinittal throughout 1984 and early 1985.

This sutxnittal contains proprietary information of Westinghouse Electric Cor;: oration. In confonnance with the requirenents of 10CFR 2.790, as amended, of the Commission's regulations, we are enclosing with this sutmittal an application for withholding proprietary information from public disclosure and an affidavit. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Ccemission. Ok

,WI g 0 8408080278 840731 W @q'Up W- 19 PDR ADOCK 05000601 K PDR Q

  • q N

'Mr. H. R. Denton Page Two Correspondence with respect to the affidavit or application for withholding should reference AW-811-TT and shcf d be addressed to R. A. Wiesemann, Manager of Regulatory and Legislative Affairs, Westi.nghouse Electric Corturation, P.O. Box 355, Pittsburgh, Pennsylvania iba:1 Very truly yours,

'N' g/ ) 'O. - [(. u %

ye [E.,P. Rahe, Jr. , Manager Tuclear Safety Department MDB/kk Enclosures cc: D. Eisenhut R. Bernero F. R. Miraglia, Jr.

C. O. Thomas