ML20093H776

From kanterella
Jump to navigation Jump to search
Amends 102 & 66 to Licenses NPF-39 & NPF-85,respectively, Revising TS Table 3.3.3-3 by Changing HPCI Sys Response Times to Reflect System Response Time of Less than or Equal to 60 Seconds Instead of Less than or Equal to 30 Seconds
ML20093H776
Person / Time
Site: Limerick  
Issue date: 10/16/1995
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Philadelphia Electric Co
Shared Package
ML20093H778 List:
References
NPF-39-A-102, NPF-85-A-066 NUDOCS 9510200338
Download: ML20093H776 (8)


Text

.

e e#* *%

y;.

-4 UNITED STATES i

5

)*

S NUCLEAR REGULATORY COMMISSION

{

WASHINGTON, D.C. 20666-0001 s...../

1 i

PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-352 LIMERICK GENERATING STATION. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.102 License ~No. NPF-39 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated May 19, 1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I; 2

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; 1

C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

4 4

9510200338 951016 PDR ADOCK 05000352 P

PDR

]

I' i

l f 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is hereby amended to read as follows:

Technical Soecifications The Technical Specifications contained in Appendix A and the' Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

102. are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days of issuance.

j FOR THE NUCLEAR REGULATORY COMMISSION 0

h.

Jo n '. Stolz, Director Pr et Directorate I-Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changas to the Teatnical Specifications Date of Issuance: October 16, 1995

1 ATTACHMENT TO LICENSE AMENDMENT NO.102 FACILITY OPERATING LICENSE NO. NPF-39 4

DOCKET NO. 50-352 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 3-39 3/4 3-39 1

i I

4 4

4 h

TABLE 3.3.3-3 EME.RGENCY CORE COOLING SYSTEM RESPONSE TIMES ECCS RESPONSE TIME (Seconds) 1.

CORE SPRAY SYSTEM s 27 2.

LOW PRESSURE COOLANT INJECTION MODE 0F RHR SYSTEM s 40 3.

AUTOMATIC DEPRESSURIZATION SYSTEM N.A.

4.

HIGH PRESSURE COOLANT INJECTION SYSTEM s 60 5.

LOSS OF POWER N.A.

LIMERICK - UNIT 1 3/4 3-39 Amendment No. 102

p* "to p-4 UNITED STATES S

NUCLEAR REGULATORY COMMISSION If WASHINGTON, D.C. 2066H001

\\...../

PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-353 LIMERICK GENERATING STATION. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 66 License No. NPF-85 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated May 19, 1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

i

)

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-85 is hereby amended to read as follows:

3 Technical Snecifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

66, are hereby incorporated into this licensi

%')cielphia Electric Company shall operate the facility in accordance w .... Technical i

Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implecented within 30 days of issuance.

F0k THE NUCLEAR REGULATORY COMMISSION i

i 4

o n F. Stolz, Dir or oject Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: October 16, 1995

ATTACHMENT TO LICENSE AMENDMENT N0.66 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 Replace the following page of the Appendix A Technical Specifications with the attached page.

The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 3-39 3/4 3-39 5

2 TABLE 3.3.3-3 EMERGENCY CORE COOLING SYSTEM RESPONSE TIMES Ef15 RESPONSE TIME (Seconds) i 1.

CORE SPRAY SYSTEM

$ 27 2.

LOW PRESSURE COOLANT INJECTION MODE OF RHR SYSTEM s 40 3.

AUTOMATIC DEPRESSURIZATION SYSTEM N.A.

4.

HIGH PRESSURE COOLANT INJECTION SYSTEM s 60 l

5.

LOSS OF POWER N.A.

LIMERICK - UNIT 2 3/4 3-39 Amendment No. 66