ML20093H674

From kanterella
Jump to navigation Jump to search
Forwards Leakage Reduction Surveillance Test Procedures & Test Data Sheets Per TMI Item III.D.1.1.Remaining Tests to Be Completed After Fuel Load.Results Will Be Submitted Per Schedule in NRC
ML20093H674
Person / Time
Site: Limerick Constellation icon.png
Issue date: 10/12/1984
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML20093H675 List:
References
CON-#484-537, TASK-3.D.1.1, TASK-TM OL, NUDOCS 8410160347
Download: ML20093H674 (3)


Text

l PHILADELPdlA ELECTRIC COMPANY 23O1 MARKET STREET P.O. BOX 8699 PHILADELPHI A. PA.19101

~

JOHN S. KEMPER V IC E-PR ESID E NT EhesNEE NONG AND RESE ARCH Mr. A. Schwencer, Chief Docket No.: 50-352 Licensing Branch No. 2 U. S. Nuclear Regulatory Ccxrtision Washington, D.C. 20555

Subject:

Limerick Generating Station, Unit 1

'IMI Its III.D.l.1 Primary Coolant Outside Containment

Reference:

J. S. Kenper to A. Schwencer letter dated Septenber 12, 1984 File: GOVT 1-1 (NRC)

Dear Mr. Schwencer:

As documented in the referenced letter, eight (see attachment 1) of the sixteen leakage reduction surveillance tests to be performed prior to fuel load in order to satisfy FSAR section 6.2.8 requirments have been cmpleted. A copy of the cmpleted surveillance test procedures including their test data sheets are provided in attachment

2. 'Ihe control Rod Drive Scram Discharge Volume Contaminated Pipe Inspection, ST-1-047-700-1, will be run again when the system is pressurized to operating reactor pressure prior to initial criticality.

Leakage limits will be established after all sixteen surveillance tests have been cmpleted.

The remaining eight surveillance test procedures to be cmpleted after fuel load including their test results will be subnitted to you in accordance with the schedule provided in the reference letter.

Sincerely, d.S Kempe PJS/mlb/10128408 cc: See Attached Service List ,

h^

0

'lu

'cc: Judge Helen F. Hoyt (w/o enclosure)

Judge derry' Harbour (w/o enclosure)

Judge Richard F. Cole. (w/o enclosure)

Judge Christine N. Kohl (w/o enclosure)

Judge Gary J. Edles (w/o enclosure)

Judge Reginald L. Gotchy '(w/o enclosure)

Troy B. Conner, Jr., Esq.. (w/o enclosure)

Ann P. Hodgdon, Esq. (w/o enclosure)

Mr. Frank R. Romano -(w/o enclosure)

Mr. Robert L. Anthony (w/o enclosure)

Ms. Phyllis Zitzer (w/o enclosure)

Charles W. Elliot, Esq. (w/o enclosure)

Zori G. Ferkin, Esq. (w/o enclosure)

Mr. Thomas Gerusky (w/o enclosure)

Director,~ Penna. Emergency (w/o' enclosure)

Management Agency-Angus R. Love, Esq. -(w/o enclosure)

David Wersan, Esq. (w/o enclosure)

Robert J. Suganren, Esq. (w/o enclosure)

Martha W. Bush, Esq. (w/o enclosure)

Spence W. Perry, Esq. (w/o enclosure) day M. Gutierrez, Esq. (w/o enclosure) I Atomic Safety S Licensing (w/o enclosure)

Appeal Board Atomic Safety & Licensing (w/o enclosure)

Board Panel Docket & Service Section (w/o enclosure)

Mr. James Wiggins (w/o enclosure)

Mr. Timothy R. S. Campbell (w/o enclosure) l

l Attachnent 1 Leak Reduction Program Surveillance-Tests Completed Prior to Fuel Load ST-1-051-701 A Residual Heat Rennval Contaminated Piping Inspection ST-1-051-702-1 B Residual Heat Removal Contaminated Piping Inspection ST-1-051-703-1 C Residual Heat Removal Contaminated Piping Inspection ST-1-051-704-1 D Residual Heat Removal Contaminated Piping Inspection ST-1-052-701-1 A Core Spray Contaminated Piping Inspection ST-1-052-702-1 B Core Spray Contaminated Piping Inspection ST-1-052-705-1 Safeguard Piping Fill Contaminated Piping Inspection ST-1-047-700-l' Control Rod Drive Scram Discharge Volune Contaminated Piping Inspection RJS/mlb/10128409

)