.Z:!;""~
M8 Jul@ S,* 1pp Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Re: Catawba Nuclear Station Units 1 and 2 Docket Nos. 50-413 and 50-414 S. D. Report No. 413-414/84-03
Dear Mr. O'Reilly:
The subject report, transmitted by my letter of March 23, 1984, stated that corrective action for Unit 1 was expected to be complete prior to fuel load.
The corrective action for this deficiency involves inspection of the over-speed govenor and fuel transfer pump drive hubs. As part of the TDI Owner's Group, we are currently carrying out a comprehensive program of inspection and testing of the Catawba Unit 1 Diesels. This program is to be completed prior to initial criticality, and we have incorporated the corrective action for this deficiency into its schedule.
Very truly yours, Ab Hal B. Tucker LTP/rbs cc: Director INP0 Records Center Office of Inspection and Enforcement Suite 1500 U. S. Nuclear Regulatory Commission 1100 Circle 75 Parkway Washington, D. C.
20555 Atlanta, Georgia 30339 NRC Resident Inspector Mr. Robert Guild, Esq.
Catawba Nuclear Station Attorney-at-Law P. O. Jax 12097 Palmetto Alliance Charleston, South Carolina 29412 21351 Devine Street Columbia, South Carolina 29205 Mr. Jesse L. Riley Carolina Environmental Study Group 854 Henley Place Charlotte, N. C.
28207 04072g60 3
$DRA PDR gn,py st/1,jo p.w