ML20093B678

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Subcooling Core Monitor Sys. Initially Reported on 840821.Testing Revealed Subcooling Core Monitor Processor Impaired When Sys Goes Into Alarm State.Engineering Evaluation Being Conducted by Ae
ML20093B678
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 09/20/1984
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Hunter D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
KMLNRC-84-162, NUDOCS 8410100185
Download: ML20093B678 (1)


Text

-

KANSAS GAS AND ELECTRIC COMPANY THE ELECTM LOMB3ANY GLENN L M O E S T E ft vecs petssoresT huctsam September 20, 1984 Mr. D.R. Hunter, Chief Reactor Project Branch 2 ggql1.g U.S. Nuclear Regulatory Commission

.7 y !

Region IV 611 Ryan Plaza Drive, Suite 1000 g) pgg Arlington, Texas 76011 KMLNRC 84-162 L

Re:

Docket No. STN 50-482 Subj: Potential 10CFR50.55(e) Interim Report -

Subcooling Core Monitor Alarm and Caution Relays

Dear Mr. Hunter:

ThJ s letter provides an interim report on a potential 10CFR50.55(e) concerning the subcooling core monitor system installed at Wolf Creek Generating Station (WCGS). This concern was initially reported by Mr. H.K. Chernoff of Kansas Gas and Electric Company (KG&E) to Mr. Lawrence Martin of the Nuclear Regulatory Commission, Region IV, on August 21, 1984.

During final testing, which utilized field inputs, of the subcooling core monitor system, it wac observed that when the system goes into the alarm state the functioning of the subcooling core monitor processor is impaired.

Initial investigation indicated that this condition is possibly the result of arcing or ' noise' interference from an adjoining alarm relay. An engineering evaluation of this matter is presently being conducted by the Architect / Engineer.

The status of this potential 10CFR50.55(e) will be carried on the monthly status update as file 53564-K150. The final report or any eignificant new information will be submitted by separate correspondence. In the interim, please direct any questions concerning this subject to me or to Mr. Otto Maynard of my staff.

Yours very truly,

//

GLK bb xc RCDeYoung Po 'Connor HBundy "h

84101001g58 h

l PDR ADOC PDa

'l0 S

201 N. Market -Wictuta, Kansas - Mail Address: RO. Box 208 l 'Mchita, Kansas 67201 - Telephone: Area Code (316) 261-6451