ML20093B441

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept DER 84-06 Re Possible Defects in Absolute & Deviation Alarm Modules Supplied by Foxboro. Initially Reported on 840216.Due to Extensive Investigation & Evaluation,Final Rept Will Be Submitted on 841031
ML20093B441
Person / Time
Site: Palo Verde  
Issue date: 09/19/1984
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
ANPP-30563-TDS, DER-84-06, DER-84-6, NUDOCS 8410100072
Download: ML20093B441 (2)


Text

m 7

o

} ^Mlt-50-5/3,5/9j53f

1ECElVED 1mc e

Arizona Public Service Company.

% SEP 24 pg g,9g September 19; h198(Cl0Ntrisp

~ ANPP--30563-TDS /1RB '

~

m UL S. Nuclear Regulatory Commission

Region V.

Creekside Oaks Office Park'

< 1450 Msria Lane -L Suite 210 Usinut' Creek; California - 94596-5368 Attention: Mr. T. W. Bishop, Director

^

Division of Resident Reactor -Projects' and Engineering Programs

Subject:

Time Extension For Report - DER 84-06 A 50.55(e) Potentially Reportable Defic 1=rg ".clati G T?

Possible Deficiencies In Absolute And Deviation Alarm Modules Supplied By Foxboro.

File: 84-019-026; D.4.33.2 Ref erence : (A) T$lephone conversation between P. Narbut and T. Bradish on February 16, 1984 (B) ANPP-29030, dated March 9,1984 (Interim Report)

(C): ANPP-29665, dated June 5,1984 (Time Extension)

(D) ANPP-30305, dated August 23, 1984 (Time Extension)

Dear Sir:

The NRC was notified of a potentially reportable deficiency in Reference ( A), an Interim Report was transmitted by Ref erence (B),

and Time Extensions were requested by References (C) and (D); ' At that time, it was estimated that a Final Report would be available by September 20, 1984 Due to the extensive investigation and evaluation required, it is now expectedEthat this inf ornation will be finalized by October-31, 1984, at which time -a: complete report will be ' submitted.'

There is no new information or change to the Interim Repor* at this time.

Very-truly yours, h

E. E. Van Brunt, Jr.

i

,8410100072 840919 PDR;ADOCK 05000528 APS Vice President PDR

.ANPP Project Director-Nuclear' Production S

EEVB/TRB/nj 1

~

cc:. See Page Two r

~

'I p.27; L:

.?.
. y

^

/

c "N

Y Mr.1T.~ W. Bishop DER 84-06 Page Two

.ce:

Richard DeYoung, Director -

Office of Inspection and Enforcement U.

S.' Nuclear Regulatory Commission Washington, D. ;C.,.20555 T. G. Woods, Jr.-

-D. B. Karner W. E. Ide D. B. Fasnacht-A. C. Rogers L. A. Souza D. E. Fowler T. D.. Shriver.

C. N. Russo J. Vorees J. R. Bynum J. M. Allen J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher H. D. Foster D. R. Hawkinson L. E. Vorderbrueggen R. P. Zimmerman S. R. F ros t L. Clyde M. Woods T. J. Bloom

. Records Center i

Institute of Nuclear Power Operations 1100 circle 75 Parkway, Suite 1500 Atlanta, GA 30339 i

f 1

-