PUBLIC SERVICE SEABROM $ TAM Engi& ONiw.

Companyof NewHampshire 1671 Worcester Road Framinghora, Mossochusetts 01701 (617) - 872 - 8100 June 7, 1984 SBN-664 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Project and Resident Programs l

References:

(a) Construction Permies CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of May 16, 1984, A. L. Legendre, Jr. (YAEC) to R.

W. Borchardt (NRC Region I)

Subject:

Interim 10CFR50.55(e) Report:

Gould Molded Case Circuit Breakers

Dear Sir:

On May 16, 1984, we reported a potential 10CFR50.55(e) deficiency

[ Reference (b)] regarding Gould molded case circuit breakers. The reportability of this item is under evaluation.

Description of Deficiency The testing of an incoming shipment of 15 Gould molded case circuit breakers resulted in 10 failing to pass the instantaneous magnetic overcurrent trip test. The 15 breakers were identical; 40-amp trip, Model HE3M040.

Approximately 75 of these 40-amp trip Gould breakers supplied in previous shipments have tested satisfactorily.

Safety Implications We are investigating the cause and safety implications of the subject deficiency.

Corrective Action We have informed Gould of the subject deficiency. The breakers are being returned by Gould to their supplier, ITE/Siemens-Allis, for inspection. Their response will determine the corrective action. We will submit an additional report to Region I by September 14, 1984.

8407020361 840607 PDR ADOCK 05000443 S

PDR

{ l oc ar t

5'

.- 6 f

i r

United States Nuclear Regulatory Commission June 7, 1984 Attention:'. Mr. Richard W. Starostecki, Director Page 2 i

This letter is being filed pursuant to the interim reporting provisions of 10CFR50.55(e)(3).

-Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY W

M i

J. DeVincentis Engineering Manager r

cc:. Atomic Safety 'and Licensing Board Service List Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 7

i r

t L

h e

William S. Jordan, III, Esquire Brentwood Board of Selectmen Harmon.& Weiss RED Dalton Road 1725 I Street K.W. Suite 506 Brentwood, New Hampshire 03833 Washington, DC 20006 Roy P. Lessy, Jr.,-Esquire Office of the Executive Legal Director Edward F. Meany U.S. Nuclear Regulatory Commission Designated Representative of

-Washington, DC 20$55 the Town of Rye 155 Washington Road Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O. Box 516 Calvin A. Canney

_!kncehster, NH 03105 City Manager

~

City Hall

' Philip Ahrens,-Esquire 126 Danie! Street Assistant Attorney General Portsmouth, NH 03801 Department of the Attorney General Augusta. ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr.. John B..Tanzer Office of the Attorney General Designated Representative of 208 State House Annex the Town of Hampton Concord, NH 03301 5 Morningside Drive Hampton, NH 03842 Anne Verge, Chairperson L

Board of Selectmen Roberta C. Pevear Town Hall Designated Representative-of South Hampton, NH 03842 the Town of Hampton Falls Drinkwater Road Patrick J. McKeon

.Hampton Falls, NH 03844-Selectmen's Office 10 Central Road Mrs. Sandra Gavutis Rye, NH 03870 Designated Representative of the Town of Kensington Carole F. Kagan, Esq.

RFD 1 Atomic Safety and Licensing Board Panel East Kingston, NH 03827 U.S. Nuclear Regulatory Commission

~'

Jo Ann Shotwell, Esquire Assistant Attorney General.

Mr. Angie Machiros Environmental Protection Bureau Chairman of the-Board of Selectmen

_ Department of the Attorney General Town of Newbury L0ne Ashburton Place,~19th' Floor Newbury, MA 01950 Boston, MA 02108 Town Manager's Office

. Senator Gordon J. Humphrey Town Hall - Friend Street U.S. Senate Amesbury, Ma.

01913 Washington, DC 20510

(Attn: Tom Burack)

Senator Gordon J. Humphrey 1 Pillsbury Street Diana P. Randall Concord, NH 03301 70 Collins Street (Attn:. Herb Boynton)

]

SEabrook, NH 03874 Richard E. Sullivan, Mayor Donald E. Chick City Hall Town Manager Newburyport, MA 01950 Town _of Exeter l'; U T:d l l C C: 22 10 Front Street Exeter,lNH 03833

'J F El!.5.C G.'d !

I 1