Text

.

AVERAGE DAILY UNIT POWER LEVEL 50-335 r

DOCKET NO.

UNIT St. Lucie #1 I

6-15 84 DATE COMPLETED BY N.W. Grant TELEPilONE (305) 552-3675' May, 1984 MONE DAY AVERAGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL (MWe Net)

-(MWe-Net) 3

,j 195 is 274

~

504

~

3 4

20 550 562

~

5 21 538 6

22 808 7

23 848 8

24 851 25 10 26 852 852

~

Il 3,

3 ~,

28 853 850

~

83 29 14 30 852 7pg

~

Ds 16 35 F

e e

INSTRUCTIONS On this format.hst the average daily unit power lesel in MWe Net for each day in the reporting month. Compute to the nearest whole exgaware.

i (9/771 L

8407020348 840615 PDR ADOCK 05000250 R

pop

._y

OPERATING DATA REPORT DOCKET NO.._ 5S335 DATE 6-1%84 c

COMPLETED BY N.W. Grant TELEPHONE (305) 552-3675 OPERATING STATUS

1. Unit Name:

St. Lucie Unit #1 Notes

2. Reporting reriod:

May 1984 Unit #1 returned to power

3. Licensed Thermal Power (MWI):

2.700 following refueling and 893

4. Namepiste Rating (Gross MWe):

scheduled maintenance.

830

5. Design Electrical Rating (Net MWe):
6. Maximum Dependable Capacity (Gross MWe):

867 822

7. Maximum Dependable Capacity (Net MWe):
8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since I.ast Report, Give Reasons:
9. Power I.evel To Which Restricted. If Any (Net MWe):
10. Reasons For Restrictions. lf Any:

This Month Yr to.Date Cumulative

11. Hours in Reporting Period 744 3.647 65,255
12. Nuznber Of Hours Reactor Was Critical 426.2 479.8 44.945.9 0

0 205.3

13. Rosetor Reserve Shutdown Hours
14. Hours Generefor On.Line 368.5 368.5 43.944.7 0

0 39.3

15. Unit Reserve Shutdown Qours
16. Gross Thermal Energy Generated (MWH) 798.009 800.034 109.467.972
17. Gross Electrical Energy Generated (MWH) 260.820 260.820 35.634.695 240,932 225,726 33.559,999
18. Net Electrial Energy Generated (MWH)'

49.5 10.1 67.3

19. Unit Service Factor
20. Unit Asailability Factor 49.5 10.1 67.4 39.4 7.5 65.1
21. Unit Capacity Factor (Using MDC Net) 39.0 7.5 63.4
22. Unit Capacity Factor (Using DER Net)
23. Unit Forced Outage Rate 4.3 4.3 4.6
24. Shutdowns Scheduled Over Next 6 Momas(Type.Date.and Duration of Each):
25. If Shut Down At End Of Report Period. Estimated Date of Startup:
26. Units in Test Status (Prior io Commercial Operation):

Forecast AtI imed INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPER ATION F

(9/77)

E

+

UNIT N AM N REN

' S 1cie Unit #1 AME DATE f 34 REPORT MONTH MaY' 1984 m gy P..W. Grant TELEPHONE (305) 552-3675

.e 33 3

jY5 Licensee

,E w Cauw & Corrective No.

Date e;-

3g i

2s&

Event p

Eb

^* * ' "

f:

5 jdi.g Repewt a mO Prevent Recurrence g

5 03 830226 S

373.9 C

4 RC FUELXX Unit #1 returned to power following refueling and scheduled maintenance.

04 840517 S

1.6 B

9 HA TURBIN Turbine overspeed trip test.

I 2

3 4

F: Forced Reason:

Method:

Exhibit G - Instructions S. Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenanceof Test 2-Manual Scram.

Entry Sheets for Licensee C-Refueling 3-Automatic scram.

Event Report (LER) File (NUREG.

D-Regulatory Restriction

%-Other (Explain) 0161)

E-Operator Training & Ucense Examination 9,

5 F-Administrative Goperational Error (F splain) 4

/.e 4. A.s w e.;,..,#

Exhibit I. Same Source 19/77)

II-Other (Explain)

y f'UMMARY CF OPERATING EXPERIENCE DOCKET NO.

50-335 St. Lucie Unit 1 UNIT DATE June 15, 1984 COMPLETED BY N.W. Grant TELEPHONE (305)552-3675 REPORT MONTH May, 1984 St. Lucie Unit I returned to power following a refueling and scheduled maintenance outage which included the repair work on the core support barrel and removal of the thermal shield.

Inspectbns and requirements of IE Bulletins and NUREG-0737 are continuing.

Florida Power & Light Company comitments for NUREG-0737 implementation are continuing. Refer to correspondence between FPL and NRC for additional information.

~

In accordance with requiremen;s of NUREG-0737 Item II.K.3.3, there were no challenges to PORV or safety valves during the report month.

e m

(".

~

AVER ACE D4ILY UNIT POWER LEVEL

~

DOCKET NO.

~

UNIT St. Lucie #2 DATE 6.15 84 COMPLETED BY N.W. Grant TELEril0NE - (305) 552-3675' s

MONTH Ma y, 1984 DAY AVER AGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL (MWe Net)

.(MWe NetI 808 37 809 810 812 2

3 809 ggp 804 812 4

20 5

786 812 21 757 812 6

22 7

777 813 23 808 811 s

24 RI2 25 812 to 812 011 26 II NI?

27 812 811 011 12 25 13 810 29 811 808 813 34 30 810 794 15 3

16 809 o

INSTRUCTIONS On this foundt. hit the aserage daily unit power leselin MWe N* for each day in the reporting in,,oth, Compute to lhe peJfft! wholt tyyJwatt, (9/77) 8 4

F OPERATING DATA REPORT 50-389 DOCKET NO. 1-15-84 DATF.

COMPLETED BY.N.W. Grant 5 TELEPHONL f305)

MTING STA TUS

1. Unit Ns ne:

it. Lucie Unit #2 Notes

2. R*P8'8 4 F*'iod-

'Y

3. Liesne J Timemel Power (MWt): - -.!'

560 Unit #? Operated at 03u essentially. full power.

4. Nanw',lete Rating (Groes MWe):
5. Desiti Electelsel Reting (Net MWe):

804

6. Most oom Depndeble Cepecity (Groes MWe):

]

832

  1. UD
7. Mealnom Dependable Cepecity (Net MWe):

S. If C1 anys Occur in Capacity Ratings (items Number 3 Through 7) 31nce Last Report.Give Reasone

9. Pc wt Leel Te which Restaleted,1f Any (Net MWe):
10. R stoni For Nestrictioru.lf Any:

This Month Yr..to.De'e Oeimilatise 74 4 3,647

,,,,,,_, 7,15 2

11. Hows la Reporting Period 12 Number Of Foots Reector Wes Critical 744 3,628.4 6.115 5.4
13. Reector Reeme Sheldown H(urs 0

0 0

3.4 IE'5""

6,623 I

14. Mours Generstw On Line 744 0

0 0

15. L' nit Reeme Shutdown (ours

-:1.829,801

,,LiOL745 3

16. Grose Thermel Energy Generated (MWil)
l ROR M4
17. Groes Electrieel Energy Genereted (MWH) 6 33,4 0L,,,

2,9 6 1,6110 5,604dOO

14. Net Electricel Energy Generated (MWH) 699,952 2,801.006 6,198,592 100.0 9 5. 11 92.6
19. Unit Serv 6ev Facto, 100.0 95.0 92.6
20. Unit Avoilobility Factor 102.6 97.7

_ J 2.5

21. Unit Cornity Factos (Using MDC Net)
22. Unit cepeesty Factor (Using DLR Net) 100.3 95 1 90.4
23. Unit Forced Outage Net, 0

3.4 7.0

24. Shutdown Scheduled Oier Nent 6 Montlit (Type.Dete.end Duration of Eachl:
25. If $liut Down At End Of Neport l'eriod.titimated Date of Startup'
26. Units in Test sielui(Prior to Commerciel operation):

Forecast Ailisi sed INiflAL CHIIICALIIY INiilAL ElIC1HICliY COM41LMCI4L OPI N Ail 0N I'l/771

50-389 UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKETNO. St. Lucie Unit #2 UNIT NAME DATE-6-15-84 REPORT MONTH MaY' 1984 COlWLETED BY N.W. Grant TE1.EPHONE (305) 552-3675

-_E E

.5 ?

3 jI3 Licensee g*,

j*t Cause & Corrective No.

Date i

3g s

2s&

Event g7

['3 a.

Acthm to 5

jdi.g Report a mO Prevent Recurrence d

Unit #2 had no shutdowns or significant power reductions.

1 M

/

^

/

a y

_f 4

I 2

3 4

F: Ferced Reason:

Method:

Exhibit G - Instructims S: Scheduled A Equipment Failure (Explain)

1. Manual for Preparation of Data i

B. Maintenance or Test.

2 Manual Scram.

Entry Sheets for Licensee i

/

C-Refueling ~

3-Automatic Scram.

Event Report (LER) File (NUREG.

D-Regulatory Restriction ~

@-Other (Explain) 0161)

E-Operatar Training (x Ucense Examination p

5 F Administrative

G.Operationalf. wir (F splain) 6. 4e ao 44 eve,..cl Exhibit I - Saine Source t')/77 )

Il-Other (E xpbin)

/-

t..

' SUIG1ARY OF ' OPERATING EXPERIENCE DOCKET NO, 50-389 UNIT St. Lucie Unit #2 DATE June 15, 1984 COMPLETED BY ll.W. Grant.

(

TELEPHONE REPORT HONTH

-Hav. 1983 Unit 2 operated at essentially full pow'er.

. Inspections and requirements' of IE Bulletins and fiUREG-0737 are continuing.

Florida Power'& Light Company commitments for flVREG-0737 implementation are continuing. Refer to correspondence between FPL and fiRC for additional

- information.

In accordance with requirements of Technical Specification 6.9.1.6 there

- were no challenges to PROV or safety valves during the report month.

. c,.

r.*.

1 '.

.l

~

D

%r

' f

+

' (