ML20092J850

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Bldg Integrated Leak Rate Test (Preoperational), Per 10CFR50,App J
ML20092J850
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 06/25/1984
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20092J853 List:
References
NUDOCS 8406270152
Download: ML20092J850 (1)


Text

.

Y

(

DITKE POWER GOMPAhT P.O. HOx 33180 CHARLOTTE, N.O. 28241'

" I.".,'. E Y ".

Juae 25, 1984 (E7dE1

.m Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station, Unit 1 Docket No. 50-413

Dear Mr. Denton:

Pursuant to 10 CFR 50, Appendix J, Duke Power Company submits herewith twelve (12) copies of a docement entitled " Reactor Containment Building Integrated Leak Rate Test" for Catawba Nuclear Station, Unit 1.

Very truly yours, dd 6T== h Hal B. Tucker ROS:scs Attachments cc: w/o attachments w/ attachments Mr. Jesse L. Riley Mr. J. P. O'Reilly, Regional Administrator Carolina Environmental Study Group U. S. Nuclear Regulatory Commission 854 Henley Place Region II Charlotte, North Carolina 28207 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Robert Guild, Esq.

NRC Resident Inspector Attorney-at-Law Catawba Nuclear Station P. O. Box 12097 Charleston, South Carolina 29412 Palmetto Alliance 21351 Devine Street Columbia, South Carolina 29205

= a== 05=ogg 3,

i$

8406270152 840625

@