Forwards Nonproprietary WCAP-13139 & Proprietary WCAP-13138, Steam Generator Tube/Tube Support Plate Elevation Alternate Plugging Criterion Summary. WCAP-13138 Withheld
ML20092J078
Person / Time
Site: Farley  
Issue date: 02/13/1992
From: Woodard J
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19344C366 List:
References
NUDOCS 9202240055
Download: ML20092J078 (4)


Text

.

?$ 0,5NY ?Y * ' " '

C2";s%i5""

k L

SoutheIn Nuclear Operating Company J.o woomo vee new i ny m,,c,n g o, a,,,n f avy bcys1 pgggggpy }3, gggg Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTH: Document Control Desk Washington, DC 20555 Joseph H, Farley Nuclear Plant

$_ team Genet t0Llyhc_Eupport Plate Alternale Pluaging Criteri.a t

Gentlemen:

On November 20, 1991, a meeting was held w;th the NRC Staff to discuss staff questions arising frort their review of the steam generator tube support plate alternate plugging criteria amendment.

Enclosed are copies of WCAPs containing copies of the overhead slides presented at that meeting.

Enclosed are:

1.

I copy of WCAP-13138, " Steam Generator Tube / Tube Support Plate Elevation Alternate P!ugging Criterion Summary" (Proprietary),

2.

I copy of WCAP-13139, " Steam Generator Tube / lube Support Plate Elevation Alternate Plugging Criterion Summary" (Non-Proprietary).

Also enclosed are a Westinghouse authorization letter, CAW-92-?SO, accompanying affidavit, Proprietary Information Notice, and Copyright Notice.

As item 1 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information.

The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR Section 2.790 of the Commission's regulations, cisDOY

\\

I 9202240055 920213 hi/'. [,fg /,

)

g ADOCK 0500 0

gDR l(}l Q

.' b $ b N' E

/

l L

/D/C

/

/ A/

o U. S. Nuclear Regulatory Commission Page two Correspondence with respect to the copyright or proprietary aspects of the items listed above or_the supporting Westinghouse Affidavit should reference CAW-92-250 and should be addressed to R. P. 01 Piazza, Manager of Nuclear Safety Licensing, Westinghouse Electric Corporation, P. O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

If there are any questions, please advise.

Respectfully, e-\\h\\b.ds-,k N(.,

. Woodard JDW/REMimap 1821 Enclosures cc: Mr. S. T. Hoffman i

t

+

i f

Proprietary Information Notice i

Trammitted herewith are proprietary and/or non-proprietary versions of documents furnished to the NRC in connection with requests for generic and/or plant-specluc review and approval, e

in order to conforrn to the requirements of 10 CFR 2.790 of the Commission's regulations concerning I

the protxtion of proprietary information 50 submitted to the NRC, the information which 15 pioprietary 1

in the proprietary versions is contained within brackets, and where the proprietary informatlon has been deleted in the non-proprietary versions, only the brackets remain (the information that was contained l

within the brackets in the proprietary versions having been deleted). The justlucation for claiming the Information so designated as proprietary is indicated in both versions by means of lower case letters (a) through (g) contained within parentheses located as a superscript immediately following the brackets

}

enclosing each item of information being identified as proprietary or in the margin opposite such information, These lower case letters refer to the types of information Westinghouse customarily holds i

i in confidence identined in Sections (4)(ll)(a) through (4)(il)(g) of the affidav!t accompanying this transmittal pursuant to 10 CFR 2.790(b)(1).

i I

i 5

i i

l i

CY41 RJM W W2 L^