4
,i ENCLOSURE DENTED TUBE SUPPORT PLATE (TSP) SAMPLE FOR DENTS LESS THAN 5 VOLTS If circumferential cracks are identified at dented TSP intersections with rotating pancake coil (RPC) (or equivalent) in the 5-6 volt range (by bobbin coil), expand dent sampling to
. include 20 percent sample of dented intersections less than 5 volts at the affected TSP elevation and a 20 percent sample of dented intersections less than 5 volts at each lower -
elevation if applicable, in the affected steam generator.
if indications are identified in the less than 5-volt dented TSP range, the expansion shall be consistent with Table 1. The result classification, as defined in Technical Specification Section 4.4.5.2, shall be utilized if the result classification is C-3, then the inspection will be expanded to 20 percent sample of the next highest TSP elevation.
9509200150 950915 PDR-ADOCK 05000327
_ P.
_