. __ ___ _-__ _ - - ____ - _ _ _ __.

i Page 1 of 6

~

.g FC'RM Nil 2 OWNER'8 REPORT FOR REPAlR$ OR REPLACEMENTS As Reevited by the Prov6sions of the ASME Code Section XI t, o,ne, Metropolitan Edison Comyany n,,,_12-17 91 2800 Pottaville Pike **e Reading, Pennsylvania.

poet 1

1 Three Mile Is16M" Nuclear 3 rient Generating Station un,, _1 No" BA 412571 DRF 6573 W ~~~

~

_Rt. 441 South Middletown. Pennsylvania

. A 37571A1.0 T1-MM-412571-001 W

a.., e -

a

.e.t o sen,e ei,en e.o. se., so. % e, ei..

n

3. Wott Performed by CPU Nuctfar._

Type Code $ymbol $ tem,. NA 100 Interpace Pkwy.

Ne" Autneria.i on No-NA Pareidoany. NJ t miret,on oeie -- NA Ae o,0

4. ioent,ficei on of sveiem._Emenancy Feedwater 6 <ei Aeoiceo.. construction caos_AN11 B31.1 is. 67_ Edmon _NA

_ Anoenee.. N-416 cose ca..

top Aponceo., td tion of section mi vimsed v Repe,r or Repiecements ie _74 Edition vith addenda thru Strmer 7$

6. Ideetdisation of Components Repoi'ed or Replaced and Repiscement Components A$ME' Code National
Receited,

$temped!

Nome of Nome of Menutecturer Board Other Year

Replaced, lyes Component Menwfectu er serisi No, No.

loentdication swiit or Replacement or Not r

_m Peerless lFE779/788 gRepaired/

j 6" Venturi Nuclear Corp NA N)

NA sReplaced NO j feerless l

iRepaired/ l NO 4

6" Venturi riuelear Corp NA NA TE 782/791 NA

!eplaced l

R i

L i

l 7, oe.cription ef wornReplace existing E 'gency Feedwater System Annubars B. Tests Conducted, Hydrc static Pnewmetic O Nominei operetias ereieure T othe' O Preceu,e 86o PSIG psi Test remo,liA

  • p FE 779/788, 900 PSIG - FE 782/791 NOTE: Swoolement4J s' eet in form of lists, sketches, or dronings mev be used, provided til site is 8% in, a 11 in., (2(informe.

tion in items 1 througt 6 on this report is 6ncluoed on each sheet, and (3) occh sheet is numbered end the number of sheets is tecnroed at the top of $1s fomt (12 82)

This Form (E00030t mov to ooteined ' rom the Oroer Dept., A$ME,345 f. 47th st-, New Yoru, NY.10017 9202200226 920213 PDR ADOCK 05000209 G

PDR

i e

e 3

r i

f f

i l

l FORM Nis 2 stocM

9. Memores NONE l

Apesuebie uen futwiers Dete eiweets to be ertwhee

+

t I

f E

CERflFICAff 07 COMPLIANCg repair /

We certify that the sietements made in the report are correct end this rtplacainantronterms to the rv.es of the reeeie er eepewoment A&Mt Code, Section x1, NA Type code symbol stemo NA Certibeste of Authorisation o.

tuoireiion oete NA

}

Manager, t

NDE/ISI Servf eeLDeie bOS

'N to y 2.

ms sened_baner er ownere omienee, ime i

. CERilFICAf t or 148tRvlCE INePactl0N l

i the unders.eed.

.id,n. e esiid eo

.s.n i.e.ed i,y ihe seisone, e,d of so,ier end e,e core veseenn.p.ciers eed ihe sie,e or province of _ Pennsylvania ene empio,ed i,y liartford Steam Boiler I61 Co.

of 1

11 art ford. Conn.

have inspected the components otocrited in this Owner's Report during the per6ed 04-04 01-10-92

_ end state that l

to the test of my knowledge end tellef. the Owner has serformed eneminations and taken corrective menwres descrited in this Owner's Report in accoroonce with the roouirements of the ASME Code, Section Xi, By e.gning this certificate neither the inspector nor his employer mehee any worrenty, supreemd or imphed, concerning the eneminations and sorrective measures descritred m this Owner's Report. Perthermore, neither the inspector not his employer shell be 11eose in any menner for any personal iniuy or propony domese or e toes of any kind erient from or conn *cted with this inspection.

i

.r i

/

Comm6nsong Yf=1807

_ Ll0 * $ A 9 A (Th taedekters 4:enetwei Natione Seers, Stete, Provines, one $neereements I

De'te

[f CI II 19 NL r

I 02/026

!t f

r P

,w r..,,-,r,

,y y

4

.,we r..,

w.

,,,...n,,.

-.u.,,e..,v,._,,

y,-v%

w..

_.w3.,,_

..,w

,,.,m

.mmm,,e.v,,-

...-wr.

,.,..ere,w, y e_-r =,#

Page 2 of 6 o.

s i

i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPL ACEMENf 8 As Requhed by the Provisions of the A$ME Code Section XI

. ~ -. -.. - - -. -,. _ _.

t I

,, g n,,, Metropolitan Edison Cotopany n,,,' 12-17-91~~ ~ ~ ~ '~ ~

2800~7ottsvIlh F b N -+

-~

Reading s Pennsylvania 1

1 i

y,,,

o, WrFeMHe~~W.F ~ ~

~

2. Pient Island Nuclear Cencrating Station 1

un;, _

re e m, f

Rt. 441 South Middletown,."ennsylvania,

J.O.8?B4_@5, CMR#90-117 "1[dde[

~

~

FeDeir OresNISUOn P 0, NO, Jteb N6., etc, p

3. Work Performed by_ CPU Nuclear

~

is pe code 5.mooi stamp NR 100 Interpace Pkwy.

authoorei on Nd 6 t

Parsippany. NJ-E.pi,,oon oei, 'l-13-92 aa are.s 1

e. ioentificei.on of system _ _llydrogen Reccnnhiner_

i 1

6. (*) AripitcW4e Coastruction Code ASME III.

is 74_ Eda.on. S 74 Adoends.._lI&l coo.cne (t,) Appbcobie Ldition of $ntiert xl utilised foe Mepairs or Heplacements 19.SL

-'f f

6 (dentification of Components Repeired or Repined ered Heptetement Componeats ASME Code Netions!

H opetred, Stemred

- Name of Name of Manufecturer Board Other Y eer Heplored.

(Yes Component Menutocturer Serial No, No.

'identif acetion Bui):. or Replacemet ofNo)

I l

Rockwo13 RTil HR-R;1A

'InternationaT 313 J1A _

iMQ000001-01.NA_ Aepaired_ lf L Rockwell NPT#

i llR-R-1B Internationa.l 312 NA

?QQQQQQJ.-QdJA Jppa_ludiUS f

- f

7. oncreon of work Etplaud _ the expanaion 10.inkhc1Lon on the inlcLand_cutic.Llincs I

of liydrogen Recombiners, llR-R-1A and IIR-R-1B with pipe.

- 9, Tests Conducted: Hydrostatic 0 Paeumatic N Nomiaal Operatina Pres.ufe O t

Other O Pressure 30.5 PS10,sl int Temp. JA

.' F NOTE: Supplemental sheets in form of lists, sketches, or diewings mey be used provided (1) site is 84 in. u 11 in., (2) intorms.

~

tion in items 1 through 6 on this report is included on es;h sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/92)

This F orm (E000301 may te obtained from the Order Dept., ASME. 345 E,47th 6t, Nm York, N.Y.10017.

l

,,,wme.,r.,,.---w.m.-,..,..mmm..-

,..-.-.m m.r..,..

y..,.m.,..m_,

_.2.m,,

...-,.~,-,._,.s..

..-.,+_,,.-,.-..,-+.,,---.m,24,--..--

~,-

. e

/

FORM NIS 2 (Back)

EE

9. Remarks Anonceme Mens.ciorer s ceia neports to de enecne:

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and th4 repair contorms to the rules of the ASME Code.Section XI.

Type Code Syrdbo! Stamp NR Ib l'13~92 Cert;ficate of Authorization No. -

Empiration Date

  1. 2.r S Services Date

[ b'-

M 19 M Sign'ed Owner or Owner's Designee Title

- CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hotdmg a va'id commission issued by the National Board of Boder and Pressure Vesset inspectors and the State or Province of Pennsylvania and employed byHartford Steam Boiler Ibl CO.

og Martford,' Conn

  • have inspected the components described in' this Owner's '*ys; wt during the period 04-04-90 01-10-92 ia

, eno,se,e ih.,

to the best of my knowledge end belief, the Owner has performed exammJtions and taken corrective measures descritied in tnis Owner's Report m accordance with ina requirements of the ASME Code, Sectiori XI, By signing this certificate neit> ** Inspector nor his employer makes any warranty, expressed or emptied, concerrung the examinations and corrective s.ee ac-ibed in this Owner's Report. Furthermore, neither the inspector nor his employer small be lisok lit any manne or ? - Sonal injury or property damage or a loss of any kind gr! sing from or connected with this

' inspection,

/,

bM'I Commissions PA-188.l. NB-5478(I)

F-inspector a Sie ature

' National Board, State, Province, and E ndorsernents

- Date 8-

/

19 k1 (12/87) m_

r~~

Page 3 of-6

. FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS L

A4 Required by the Proylsions of the ASME Code Section XI i, o norFetropolitan Edison Cotnpany osie__12-17 2800 Pottsville Pike **e Reading. Pennsylvania Sheet 1

o#

1 Three Mile

2. Pient Island-Nuclear Generating Station unit 1..

me me.

Rt. 441 South Middletown. PennE vania 1.o. 2175. 2176I 2199-1 Aserem neo it ore.niesoen e o. we., aos %e., et.,

3. Work Performed by CPU Nuclear Type Code Symboi Stemo M

100 Interpace Pkwy..

Authonsecon No, NA Parsippany, NJ Experei;on oei. - NA Ad dress

4. Identificei on of System Main Steatn
5. (el Apolicebte Construction CodeMLB31 I te.,62, Edition. NA Anoenos, N-416 Coo Come thi Acciacee9. taition of section xi uuiised for m oeirs or nooinements is74 edition with addenda Summer 1975
s. loentification of Components nopeired or nooixed end meci coment Components ASME Coos
Receired, Stemoed National

.eme of -

Name of Manufacturer Board Other --

Y ear

Roolaced, lyes c noenent uenuf=turer serial No.

No.

toontification Built or Rool=ement or Nel I~

Repatr/

'j Valve Yarway NA NA MS-V-29D 1974 Replace NO Repair / _

E2" Valve' Yarway NA ~

NA MS-V-29A 1974 Replace NO Repatr/

_ 2" Valve Yarway NA_

NA MS-V-290 1974 Replace NO 7, ce.cri;ition of wort Reclaced (3) Hancock 600# valves with (3Y Yarway 1500# valves ancj

~

associated pipigj.

8. Tests Conducted: Hydrostetic 0 Paeumeiic 0 Nomiasi Operei'aiPreesure 3 Other O Presaure_.187 1.1938 Test Tomo *

'e NOTE: Sucolemental eheets in form of liets, sketches, or drowings frwy be used, prtwiend til size is 84 in. m 11 in,. (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered an't the number of sheets is recorded et the top of this form.

(12/821 This Form (E00030) may be obtained from the Order Dept, ASME,345 E,47th St., New York, N.Y,10017 n

L I..

s t

i a

I.

+

t!'

r FORM NIS 2 (Bock)

9. Fiemarks_Th0J!Prgy,_ heads are not within Section XI scope, only the velds e,ncame u. nut-t

,e, s o... n.,o,,s to h..n. he.

,Icquired_to_facilitaic_ the _i r r ep l a c etne n t.

._ Code _CastJ-s1ftinvoked._to_ relieve _. hydro requirement.

CERTIFICATE OF COMPtlANCE We certify that the statements made in the report are correct and this_lePai r conforms to the rules of the

'***""D'""1 ASME Code, Section xis N

Type Code Symbol Stamp Ib Certificate of Authorization No.

Expiration Date.

Managers NDE/ISI 3ervices o,,, MS

//

ig_9 2.

Signed

- r or Owner's oestnee. Title Own CERTIFICATE OF INSERVICE INSPLCTION t, the undersigned, hold ng a valid commission lasued by the National Boerri of Doiler end Pressure Vessel inspectors and the State

{]

Pennsylvania and employed by_artford Steam Botlel 161 Co et x or Province of 11artford, Conn. have inspected 'the components described in this Owner's Report dur!ng the period 04-04_90 01-10-92 , and st.te inat. to to the best of my knowledge and belief, the Owner has performed examinations and tak en corrective measures described in this -- - Owner's Report in accordance with the requirements of the ASME Code, Section XI, - By signing this certificate neither the Inspector nor his empioyer makes any warranty, expressed or imphed, concormng the examinations and corrective measures described in this Owrier's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising f rom or connected with tnis inspection. Commissions _ PA-1887_. NB-541.af1)_ / ~.,i.n...o.,d. S,.... ,0. nc...n. e ne.rsem. : -,4...__or.s.,en.,yrg FES j) ,e 92 ~ Date p 02/s2) s c P 1 VI 2

Page 6'of 6 FORM Nil 2 0WNER'S REPORT POR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI j 1 3, %, Metropolitan Edison Company n,,,_ 12-17-91 2800 Pottsville Pikk a 1 1 1 Reading Pennsylvania

shes, of i

Three Mile 1 2, Pient. Island Nuclear Generating Station un,t Nome J.O. 2367: 2371s 2372, 2377, 2380s Rt. 441 South Middletown, Pennsylvania. 2395. 2397. 2400 ) .e. aweir oreeniseven to. No., Joe No.. eu,

3. work performed py GPU Nuclear Type Coos symeni stemo NA 100 Interpace Pitwy.

Authoriset.oa No. NA N'** Parsippany, NJ Enoireiion Date NA ) i As eroen

4. loentifestion of System Main Steam S. fel Apolleme*onstruction Coon _ AMRT R'll _1 13,,6,2,,, Edition. VA A0dence. _ M-416 Code Case

<ti Aposicanie saiuon of section mi viaised v r Recein or Reciecoments is 74 Mition with Addenda thru Summer 75 o

6. Identdication of Components neceired or Rooieced and Repiecement Component I

ASME Cooe Nationel

Receired, Stemoed Name of '

Name of Manufacturer Board Other Y es,

Reeleced, (Yes Men tecturer Serial No.

No, Identificotson Built or Roolece W nt or Nel Component u Il " 1500# Repaired / s Valves Yarvav NA NA SEE RINAREM NA Reolaced NO - i f 7; 0eectiotton of worm Reclaced (8) erfstinsr % ncock 14" 6004 valven virh (M Yarunv 14" 1500# valves. 8 Tests Conducted:. Hydroetetic 0 Paeumstic O Nomiasi operatia. Proesure T Other C Proesure887. 5 PSTfe4 TestTemo. MA ,r NOTE: Swooiemental shesis in form of tiets, sketches, or drowings vrey be used, provided (1) size is 3416. n 11 in (2) Informs. tion in iteme 1 through 6 on this report is incluesd on each sheet, and (3) each sheet is numeered and the number of sheets is recorood et the too of this form. (12iB2) This F orm (E000301 may be octeined from the Orcer Deot., A5ME,345 E,47th St., New York. NJ.10017 +. 5-% 1_ w r y as, w-v. I'

1 m r= 8 4-r FORM Nis.2 (tecki i - g, nome,s, Replaced (8) 600# Hancock valves MS-V-73B, MS-V-60B, MS-V-59B..MS-V-23A. .l aoeiiceoie uen vecturire ceio asoerie se no eneen.e o MS-V-73A. MS-V-60A. MS-V-59As and MS-V-238 with new 1500# Yarway valves and i ammaelated_picine. - caRTiriCATE or Court.i4NC _ repair / - We certify that the stetements moos in tne report are correct one thier.RP,14 cement. conforms to tne rwies of the _ .f ASME Cooe. Section XI,- = q NA Tvoe Cooo Sympoi Stemo Certificeto of Authorifatio'n No. Empiretion Dete-M b3 // j, 9 L l ' Siened I Services ooge ownee er owners Des *enes. Titie CERTIFICATE OF INSERVICE INSPECTION 1, the uncertigned, holding a vei6d commission steued by the Nationes meerd of Soiler and Proewre veessi inspectors and the State - or province o, Pennsvivania ' .ne empioyee p, Hartford Steam Boiler I&I Co. e, Hartfrerd. Conn. no e in.ected the component, aoecticed in this owner's Report during the oored 04-04-90 01-10-92 io , one sie,e gne, to the nest of my knoweege and beinf, the Owner has performed enemir.ations and taken correctiw meeswees oescribed in this owner's Report la accoreence with the roovirements of the ASME Code, Section XI. By smning this certificeio neither the inspector nor his empioyw mense any worrenty, e pressed or imotied, concerning the 'esammetione and correct w measures described in th s Owner's mooort. Furthermore, neither the ineoector not his empiover snesi ne lieele in any menner for any moreonel laiury or property demase or a loss of any kind arising from or connected with tais - ineoection. Commin.ons PA -1887 'NB S4IO N L 2 y 5amesters tiensfre - Nwenes seers. stew. Province ene a seersemente - no,, ' [Q' M tg k . 112/02)- s l l v. w .--~v r 7 4 - - - + - y w e n +

~ Page 5 of 6' e. - N e FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, OwnerEgtropolitan Edison Company osie 17-31 --2800 Pottsville Pike"'** PsgAdinni Pennsylvan1A. sheet 1 af 1 Three Mile 'a e 2i Pient Island Nuclear GeneratinR Station Unit 1 N'** BA 418736 DRF 061297 L 441 South Midd1_q. town. Pennsvivania WA 31736010 T1-MM-418736-139 A s.o. asocir oreenisetion e.o. we., son we, ei.

3. Work Performed by -GPU Nuclear Type Coo, symbol stemo NA 100 Interpace Pkwy.

Authori,sinon No, NA-Parsippany. NJ Espireiion oote _ NA AOdrete 4, loentifwetion of 5vstem Leak Rate Testina ~ AS

5. tel Apoticab4e Construction C& ISI B31. 7 1913 Edition,. N A
Aodence, NA Code cens

- (b) Apoicecie Edition of Section XI Utill:ed for Receirs or Rectocements 19 74 Edition with Addenda Sununer 75 . 6. Identification of Components Repaired or Repieced and Reptocement Components ASME Code National

Receired, siemped

- Nome of 1 Name of Manufacturer Soord Other Year

Replaced, lyes Component Manufacturer Serial No.

No. Identification Built or Roolacement orNot i Penetration

  1. 414

-(SEE REMARKS) 1970 Repair NO l-Penetration

  1. 415 1970 Repair NO Penetration
  2. 416 1970 Repair NO

.= 7; Oescretion of wo,n (SEE REMARKS)

8. Tests Conducted: - Hydroetetic

- Pneumatic @ - Nominal Operating Pressure Other C. Proesure80 PSIG - pol - Test Temp, MA

  • p.

NOTE: Suppiernemel sheets in form of lists, sketches, or drawings truy be used, provided (1) size is B4 in, a 11 in., (2) Informs-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this formJ (12/82) This Form (E000301 may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 .-.e , +, - -+ . -.. -,.- - ~ _, ,+ .n.-,

49 e s FORM NIS 2 (Back) Installed blank flanges on Penetration #414 both inside and outside the g n,.na, s Aeonc.oie venu+.ctu,Get o.t. m.norts to oe att.cneo Reactor Building. eliminating existinR connectinR Leak Rate piping. Also at Penetrations #415 and #416 the_qQnnectitig_ Leak Rate eininn outside of contp_ijiment was modified by adding 2 sets of flanges at each penetratio2. thus provid.iDL removable flanged spoolpiece at both penetrations. CERTIFICATE OF COMPLlANCE We certdy that tne statements mode in the report are correct and this _ reDair conf orms to the rules of the ASME Code, Section x1. NA Type Code Symbot Stamp NA Eng.r.iion o.te NA Certificate of Authorization No. V7 NDE I Servicebie FEa // ,,92._ sign.o o-.c or o-.c : o.sion.. ,,,,e l-CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, hoiding a valid commission issued by the Nationai Board of Boiler and Pressure Vessel Insoectors and the State Hartford SteSM Boiler I61 CO. of -. or Province of PennSV1Vania' and empicyed by Hartford. Conn. h,ve inspected the components described 04-04-90 01-10-92 . ano state inat to _ in tnis Owner's Report during the period to the best of my knowledge and benet, the Owner nos periormed examinations and taken corrective measures descreeo in this Owner's Report in accordance with tne requirements of the ASME Code, Section XI, By signing this certificate neither the insoector nor his employer makst any warranty, espressed or imphed, concernmg the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer small be liaDie in any manner for any personal injury or property damage or a loss of any klad arising from or connected with this inspection. PA-1887 gg f476 @ U Commissions ' inspector's Sienatfe National Boaro, State. Province. ano Encornements .M // gg [2 Date (12/82) - t}}