Responds to NRC Ltr Re Violations Noted in IE Insp Repts 50-321/84-05 & 50-366/84-05.Corrective Actions:Qc Inspectors Trained to Review Details on Design Documents Before Performing Insps
ML20092F588
Person / Time
Site: Hatch  
Issue date: 04/16/1984
From: Gucwa L
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20092F529 List:
References
NED-84-195, NUDOCS 8406230510
Download: ML20092F588 (2)


Text

..

."~ *i Georgia Power Cornpany '

333 Piedmont Avenue

.7[)

Attanta Georgia 30308 Telephone 404 5266526

~

Marting Address:

Post Office Box 4545 Atlanta, Georgia 30302 h

75 a 9 : 2 4 Georgia Power L T.Gucwa the southern elminc system Manager Nuclear Engineering neef Nucle r Engineer NED-84-195 April 16, 1984 U. S. Nuclear Regulatory Canaission REFEIENCE:

Office of Inspection and Enforcement RII: IKD Region II - Suite 2900 50-321/50-366 101 Marietta Street,IM Inspection Report Atlanta, Georgia 30303 84-05 ATID EION: Mr. James P. O'Reilly GENITREN:

The following information is subnitted 'in response to Inspection Report 84-05, which concerns the inspection conducted by Mr. J. T. Lenahan of your office fran February 21 to February 23, 1984.

One apparent violarion was identified.

VIOIATION:

"10 CFR 50, Appendix B Criterion V, requires that activities affecting quality be prescribed by docunented instructions, procedures or drawings and be accanplished in accordance with these instructions, procedures or drawings. Georgia Power Procedure HNP-821 requires that safety-related plant modifications be inspected to verify that the work is canpleted in accordance with details on the design docunents.

Contrary to the above, during inspection of masonry wall modifications,

. quality control inspectors failed to detect that the welding used in connections of the flanges of W8 x 35 steel' member was not accomplished in accordance with the details shown on the design docunents.

'1his is a Severity Imvel V (Supplanent I) violation."

l l

l 8406230510 840604 i

PDR ADOCK 05000321 G

PDR a

..ps Georgia Power 1 U. S. Nuclear Regulatory Ccanission Office of Inspection and Enforcenent Region II - Suite 2900 April 16, 1984

- Page 'IWo RESK)NSE Admission or denial of alleged violation:

The violation occurred as stated.

Reason for the violation:

%e quality control inspector failed to follow existing plant procedures. %e inspector did not verify that the steel members were welded per the details on the design doctments.

Corrective steps which have been taken and results achieved:

%e discrepancy between the type of welding used and the type specified on design doctments was originally identified as an unresolved iten in Inspection Reports 83-24 and 83-25, dated Septenber 8,

1983.

After reviewing the finding, plant personnel determined that the groove welds used to attach the steel menbers were more appropriate for this application than the fillet welds specified on the design documents.

We Architect / Engineer (A/E) was contacted to obtain its concurrence.

The A/E responded on September 29, 1983, stating that the use of groove welds instead of fillet welds was acceptable.

i future violations:

On Corrective steps which will be taken to avoid Novenber 1,

1983, training was given to all Georgia Power Capany-quality control inspectors.

This training stressed the importance of i

reviewing the details on design doctments before performing inspections.

The training also enphasized that, when weld fabrication details are reviewed, the relationship between the weld symbols - and steel menber configuration should be considered to determine code validity.

Date when full cmpliance will be achieved:

Full cmpliance was achieved on Novenber 1,

1983 when the type of - welding used was determined to be acceptable and the quality control inspectors were trained on the importance of reviewing the details on design doctments before performing inspections.

l Please contact this office if there are any questions.