PROGRESS REPORT FOR THE THIRTY-SIXTH QUARTER On STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK NUCLEAR GENERATING STATION To GPU NUCLEAR CORPORATION May 31,1984 by R.E. Hillman and C.I. Belmore REPORT NO.15235 February 1,1984 to April 30,1984 BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts 02332 Battelle is not engaged in research for advertising, sales promotion, or publicity purposes, and this report may not be reproduced in full or in part for such purposes.
8406210370 840613 PDR ADOCK 05000219 R
TABLE OF CONTENTS Page EXECUTIVE SUMM ARY " + " + ' ' " " ' " ' + ' " " ' ' " ' " ' " " ' " "
i INTRODUCTION " ' ' ' ' " " ' ' " ' " " " ' " ' ' " " ' " " ' ' ' " ' " -
1 PROCEDURES AND INTERIM DATA " " "
' + " "
" + + "
2 Exposure Panels " ' " " " ' ' " ' ' ". " " " " " ' ' " " " ' ' ' ' ' "
2 Water Quality " ' " " " '. ' ' " " " ' " ' ' ' ' " ' " ' " " ' ' ' " "
2 Teredinid Gonadal Development Studies " " " " ' ' " ' ' ' ' " ' ' ' " '
2 LIST OF TABLES Table 1.
Geographical Locations of Exposure Pane! Arrays in Barnegat Bay, New Jersey..
4 Table 2.
Incidence of Teredinidae in Panels Removed February 13-14, 1984 " ' "
8 Table 3.
Incidence of Teredinidae in Panels Removed March 19-20, 1984 " " " "
9 Table 4.
Incidence of Teredinidae in Panels Removed April 16-17, 1984 " ' ' "
10 Table 5.
Incidence of Limnoria in Panels Removed February, March and April, 1954 " " "... " ' ' " ' " " ' " " ' ' " " ' " ' " -
11 Table 6.
Water Quality at Exposure Panel Stations, February 13-14, 1984 ' ' "
12 1
Table 7.
Water Quality at Exposure Panet Stations, March 19-20, 1984 ' ' ' ' -
13 Table 8.
Water Quality at Exposure Panel Stations, April 16-17, 1984 ' " " " -
14 Table 9.
Condition of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from January through March,1984 """"
15 LIST OF FIGURES Figure 1.
Outline of Barnegat Bay Showing Geographical Locations of Exposure Panels. " ' ' ' " " ' ' ' '. " ' " " ' ' '. ' ' ' ". '
3
i EXECUTIVE
SUMMARY
This progress report presents data from field and laboratory work during the period February 1 to April 30,1984. Also included are the results of observations on gonad development in samples collected in January, February and March,1984.
All field work during this quarter was carried out by GPU Nuclear personnel.
Tcmperature, salinity, dissolved oxygen and pH were measured and recorded at each of the 20 stations during the three periods of exposure panel exchange.
The exposure panel exchange in March,1984, was a week later than scheduled due to weather conditions. Panels installed in March were pre-soaked for three weeks instead of the standard two weeks.
A few timnoria tunnels were found in the long-term exposure panels removed fr:m the station at the mouth of Oyster Creek in February,1984. Two of the tunnels were occupied and five of the seven tunnels were made by juveniles.
No unusual aspects in the biology of the teredinids collected during the present r: porting period were observed. Gonadal tissues from the January collections showed mostly spent or early active stages.
Those studied from the February and March c:llections showed mostly early active stages, as gonad development proceeds toward the spring and early summer spawning periods.
1 PROGRESS REPORT FOR THE THIRTY-SIXTH QUARTER on STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK NUCLEAR GENERATING STATION to GPU NUCLEAR CORPORATION May 31,1984 by R ht E. Hillman and C.I. Belmore REPORT NO.15235 February 1,1984 to April 30,1984 from BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts 02332 INTRODUCTION Battelle's New England Marine Research Laboratory is ccnducting an investigation to determine whether the Oyster Creek Nuclear Generating Station is offecting the resident marine borer population in Oyster Creek to the extent that that population is contributing significantly to marine borer-caused damage in Barnegat Bay.
A description of the program and procedures used may be found in the eighth cnnual report titled, " Study of Woodborer Populations in Relation to the Oyster Creek Generating Station", dated February 15,1984.
This report presents data for the thirty-sixth quarterly period from February 1 to Aprl! 30, 1984.
2 PROCEDURES AND INTERIM DATA Exposure panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods of February 13-14, March 19-20, and April 16-17,1984. Long-term and short-term panels at all stations were retrieved and r;placed by personnel from GPU's Oyster Creek Nuclear Generating Station.
Exposure panels installed in March,1984 were pre-soaked for three (3) weeks due to postponement of the panel exchange for one week because of weather conditions.
Table 1 describes the geographical locations of the exposure sites. Data from the laboratory examination of the panels are presented in Tables 2 through 5.
P-ter Quality Salinity, water temperature, dissolved oxygen and pH were taken at each site by the GPU Nuclear field team.
Results for February, March, and April,1984 are pr:sented in Tables 6 through 8.
Teredinid Gonadal Development Studies Table 9 shows the gonad condition of teredinid borers collected in January, FIbruary, and March,1984. Included are results from panels exposed for periods ranging fr:m 6 to 12 months.
3 j@
MANASQUAN
'NLII SmitLLE PO. INT
- %AS mA, IN?mAC0ASTAL -
wafgewAv CANAL MANTO8.0MileG 1S N
LE Castg 5
)
SEAS 40E te F
SLOOP CREEK ATLANfic CCE AN
'd MOLLY Pang C*
STOUTS CREEK ICS g
sgoog i
to ISLANO 1,
)Ov5ftm 1
t0A o
S$
9Q
((CAEEK 0,7 l 8
SARNEGAf INLET OYSTER CREEK J 4'
SAANEGAf Starfoy 4A WARETOWN l CITY 4
l SARNEGAf StACH f
f5 0
$ PANEL Ammay 0
0 2
3 A
MeLES 4
[
I SARNEGAf INLET NEW Jgmsgy e
LAM
- se ass N
[
LM8 wee 1 A 04 0 W 2
'4 k
FIGURE 1.
OUTLINE OF BARNEGAT BAY SHOWING GEOGRAPli!C LOCATIONS OF EXPO 5URE PANELS
l TABLE 1.
GEOGRAPHICAL LOCATIONS OF BATTELLE NEW ENGLAND MARINE RESEARCH LABORATORY'S EXPOSURE PANEL ARRAYS IN BARNEGAT BAY, NEW JERSEY Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Lorptude 1.
Barnegat Coast Guard Finger Pier WC1 Lat. 390 45.8'N Station, Barnegat Inlet Bulkhead WFCL 1948-l%7 Long. 740 06.5'W 2.
Ashton Marina Bulkhead WC 13,14 Lat. 390 40'N 1450 Bay Ave.
Long. 74013'W Manahawkin 3.
Iggie's Marina Bulkhead WC 16,17,18,19 Lat. 390 45'N East Bay Ave.
Long. 740 12.5'W Barnegat (Conklin Island) 4.
Liberty Harbor Marina Bulkhead WC 21 Lat. 390 47'N Washington Ave.
R. Turner Long.740 ll'W Waretown Rutgers U.
l 4-A *.
Holiday Harbor Marina Bulkhead WC 21 Lat. 390 48'N l
Lighthouse Drive R. Turner Long. 740 Il'N Waretown Rutgers U.
5.
Mouth of Oyster Creek, Dock WC 29,30 Lat. 390 43.5'N Lot 4, Compass Road Rutgers U.
Long. 740 10.3'W Offshore End 6.
Oyster Creek 1 Dock Lat. 390 48.5'N Lagoon, Inshore End Long. 740 10.35'W 37 Capstan Drive i
I
l l
l l
TARE F 1. (Continued) l l
Structure 4o be used for Nearest Previous
?
ste Latitude 1
See No.
Site
'n of Rack Data Stations
"" and Langitude 7.
Private Dock End of Dock WC 27,28 Lat. 390 48.5'N Dock Ave.
R. Turner Long. 740 ll.I'W Oyster Creek Rutgers U.
Sands Pt. Harbor Waretown 8*.
Oyster Creek Bulkhead 1500 it.
WC 26 Lat. 390 48.7'N Discharge Canal east of the R.R.
Long. 74012'W bridge l
9 *.
Forked River Metal pier WC31 Lat. 390 49.2'N South Branch Long. 74012.2'W Intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 390 50.I'N Bay Ave.
Long. 740 ll.6'W Forked River 10A*.
Private Dock Under Dock Lat. 390 49'N 1217 Aquarius Ct.
Long. 74010'W Forked River i
10B*.
Private Dock Under Dock Lat. 390 49.4'N 1307 Beach Blvd.
Long. 74010.I'W Forked River i
11.
Forked River Bulkhead WC 35 Lat. 390 49.7'N (near rnouth)
Rutgers U.
Long. 74010'W I413 River View Drive i
l
TABLE 1. (Continues 0 Structure to be used for Nearest Previous Appra='-se Latitude Site No.
Site Suspens;on of Rack Data Stations and Longitude 12.
Stouts Creek Bulkhead WC 38, 40, 41 Lat. 390 50.5'N 1273 Capstan Drive R. Turner Lor.g. 740 08.8'W Wurtz Rutgers U.
13.
Rocknak's Yacht Basin End of Pier WC 46 Lat. 390 52'N Seaview Ave.
Long. 740 09'W Lanoka Harbor Cedar Creek 14.
Dicks Landing Pier WC 49 Lat. 390 54'W
'-land Drive R. Turner Long. 740 08.I'W Bayville (Holly Park)
Nelson 15.
Winter Yacht Basin Inc.
Pier WC57 Lat. 400 02.5'N Rt.328 Long. 740 04.9'W Mantoloking Bridge 16 *.
Berkely Yacht Basin Pier WC 60,61 Lat. 390 55.9'N
- 3. Street Long. 74o 04.9'W Seaside 16A*.
Municipal Dock Pier WC 60,61 Lat. 390 56.6'N Seaside Heights Long. 740 04.9'W 16B *.
Bayside Boats Pier WC 60,61 Lat. 390 36.6'N State Highway 35 and Long. 740 04.9'W Bay Bouievard I
Seaside Heights, N3 l
1
TABLE 1. (Continesed)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Sasspension of Rack Data Stations and Lorptude 17.
Island Beach Pier WC 68 Lat. 3a0 47.!N State Park Long. 740 05.9'W (Sedge Island)
All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Racks hung with nylon line from existing structures so the bottom panels are close to, but not touching the bottom.
WC = Woodward-Clyde WFCL = William F. Clapp Laboratories N
Site 4-A installed April,1977.
Sites 10A,10B installed April,1978.
Site 16 discontinued November,1981.
Site 16A installed December,1981 - discontinued June,1982.
Site 16B installed June,1982.
Sites 3 and 9 moved from original locations November,1983.
8 TABLE 2. NCIDENCE OF TEREDINIDAE M PANEL 5 REMOVED PEtatUARY lble,1984 No. of Percent Siae Range Station Penel "g::: r Philed in mm.
Specase identification Romerke 1
P*
600+
99 600 Teredinideen only 13% of panel received. None live.
C 0
2 P
1
<2
!!)
! T. navails
~
C 0
4 P
3
<1
<l 3 Teredinidae" C
0 3
P i
<l 32 I g. gog C
0 10A P
1 2
145 i J,. navalls C
0 105 P
1 2
133
- 13. god, C
0 11 P
9 3
2 163 33 2
navalls C
0 12 P
1 1
85 I I. navain C
0 13 P
2
<l
< l.6 2 Teredinidae" C
0 14 P
3 1
41 100 2 0. ouldi, i Tere ini 4e" C
0 15 P
1 41 41 i Teredinidae" C
0 17 P
20 2
41 83 12 J,. navalis, I faredo opp.,
7 Teredinidae" C
0 Stations 3,4A,610,168 No Teredinidae present.
P e Long term panel submerged August 1 2,1983.
C e Shott. term panel submerged January 910,1984 a Long. term panel removed November 7,1983 due to teverity of attack.
" e Not spectated due to size or condition.
9 TABLE 3. INCL 0ENCE OF TEREDINIDAE IN PANEL 5 REMOVED MARCH 19-20, 1984 No. of Porcent 5tae Range Station Panel Specimens Pilled in mm.
Species identification l
i P
300+
10
<!-44
!)0 f. navalis, 370 Teredinidac
~
a C
0 11 P
22
<l
<!-12
) Teredo spp.,
l 17 Teredinidae*
C 0
14 P
4
<1 15 i Bankla spp.,
3 Tete"dinidae
- C 0
17 P
16
<1
<! 6 2 Teredo spp.,
14 Teredinidae*
C 0
Stations 2-108,12,13, IS,1615 - No Teredinidae present.
P e Long terrn panel submerged Septernber 6 7,1983.
C = Short term panel subrnerged February 13 14, 1984.
- . Not speclated due to size or condition.
i 10 l
TA8LE 4. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED APRIL 16-17, 1984 No. of Percent Slae Range i
Station Panet Specinions Filled in mm.
Species identification P
630 1
<!-2 680 Teredinidae*
C 0
1 17 P
2
<l 1
2 Teredinidae*
C 0
l Stations 2-161), - No Teredinidae present.
{
P = Long terrn panel submerged October 4 5,1983.
C e Short-terrn panel submerged March 19-20, 1984.
- e Not speclated due to size.
?
i P
11 i
l TABLE 3. INCIDENCE OF LIMNOMIA IN PANEL 5 REMOVED FEBRUARY, MARCH, AND APRIL, IM4 M__
February March Astil No. of No.of No. of No.of No. of No.of Station Panel Tunnels Specirnens Tunnels Specirnens Tunnels Specirnern i
P 0*
5 0
3
)
C 0
0 0
2 P
50 10 5
2 2
i C
0 0
0 3
P 2
2 1
0 0
C 0
0 0
4A P
380 300 30 10 0
C 0
0 0
P 7
2 0
0 C
0 0
0 0
5tations 4,617, no I.,lrnnoria present.
P o Long terin panel, subinerged 6 rnonths.
p a Short terin panel, subinerged ! rnonth.
- o Panel reinoved Noveinber 7,198) etue ta severe teredinid attack.
l 12 i
e TABLE 6. WATER QUALITY AT EXPO 5URE PANEL STATIONS FEBRUARY,1984 m,_-_._,
=-
.-_ _ __m__
Depth in Salinity Temperatwe 02 Station Date Time Poet o/oo
(*C)
(mg71) pH I
2/I3/84 0920 2.5 28.2 4.8 11.6 8.2 2
2/13/84 1000 2.0 19.8 3.3 11.6 8.2 1
2/13/84 10)0 1.0 21.8 3.0 13.2 8.3 4
2/13/84 1030 3.0 21.8 3.0 12.2 8.1 4A 2/l)/84 1100 1.3 17.3 3.0 12.6 8.3 3
2/13/84 1842 1.0 7.0 6.4 13.2 7.2 6
2/13/84 1200 1.3 11.8 3.6 13.8 8.1 7
2/l)/84 1213 2.0 17.0 6.0 12.6 8.1 8
2/13/84 1234 1.3 3.)
7.2
- 13. )
6.7 9
2/11/84
!)30 3.0 16.5 3.)
12.0 7.7 10 2/l)/84 1323 3.0 11.1 3.)
12.6 7.9 10A 2/11/84 1420 0.8 14.6 3.3 12.8 8.0 10ft 2/l)/84 1440 2.0 16.9 3.)
13.2 8.2 11 2/l)/84 1436 0.8 17.1 3.4 12.6 8.)
12 2/13/84 1530 1.3 13.3 3.0 12.4 7.9 13 2/14/84 1242 2.0 2.8 8.6
!).0 6.7 14 2/14/84 1223 3.0 14.2 6.8 13.1 8.)
13 2/14/84 0900 2.0 18.2 6.)
12.4 7.9 161) 2/14/84 0938 3.3 14.)
3.4 13.6 8.2 17 2/14/84 1040 1.0 24.8 8.8 12.1 8.)
i
= = = =.
= =
= = =
_====--
= =
1
13 TAnLE 7. WATER QUALITY AT EXPOSURE PANEL STATIONS MARCH,1984
.a
_ _ = _ _ - - = - - _ = - - = = =
= = = -,
Depth in Salinity Temwatwe 02 Station Date Time Feet e/so iSC)
(mg/l) pH I
3/19/s4 0910 7.0 25.2 5.2 10.4 7.s 2
J/19/s4 0945 5.s 19.2 6.0 9.5 7.7
)
3/19/s4 1012 2.0 18.2 6.0 9.6,, 7.7 4
J/19/s4 103) 4.0 is.s 6.0 9.4 7.6 4A J/19/s4 1050 2.5 18.0 6.2 9.s 7.6 s
J/19/44 1110 2.0 4.s 7.0 10.8 6.s 6
3/19/s4 112) 3.0 11.s 6.2 11.2 7.1 7
J/19/s4 1140 4.0 16.5 6.2 10.6 7.)
s 3/19/s4 1200 3.0 16.2 6.s 10.5 7.s 9
3/19/s4
!)20 5.5 is.s 6.1 10.4 6.s 10 3/19/s4 141s 4.9 13.0 7.0 10.4 7.1 10A 3/19/s4 l)45 2.0 13.5 s.s 10.2 7.)
10M 3/19/s4 1400 3.s 17.1 7.1 9.s 7.7 11 3/19/s4 1415 2.0 6.6 s.
11.6 7.0 12 3/19/s4 1500 3.0 16.2 6.5 11.2 7.7
!)
3/19/s4 1526 1.0 15.s 6.2 11.1 7.7 14 3/19/s4 1343 3.s 16.5 6.2 11.0 7.s is 1/20/s4 0:40 3.0 16.6 6.5 11.)
7.s 16n 3/20/s4 0917 4.0 14.0 6.2 10.s 7.5 17 1/20/s4 loss 1.5 21.s 7.5 9.s 7.s
= - -.
.. =
= = = = =
==
:==
14 TABLE 8. WATER QUALITY AT EXPOSURE PANEL STATIONS APRIL,1984
-.-
- n =
-. - _ - _ =.n m_-
a=_,- -
Depth in Salinity Tom prature Station Date Time Feet e/se ieC)
(
!)
pH i
4/16/84 0940 7.5 23.9 8.0 9.6 7.8 2
4/16/84 1034 6.5 17.2 10.2 9.8 7.6 3
4/16/84 1803 3.0 13.2 10.8 9.6 7.5 4
4/16/84 1830 4.8 13.2 11.0 8.8 7.2 4A 4/16/84 1135 3.0 14.1 11.4 9.0 7.5 3
4/16/84 1214 2.5 2.0 11.4 10.7 6.4 6
4/16/84 1244 3.5 2.1 11.4 10.8 6.4 7
4/16/84 1258 2.5 0.5 11.6 10.8 4.5 8
4/16/84
!)24 3.5 1.1 11.9 10.6 S.1 9
4/16/84 161) 3.0 11.2 11.5 7.6 6.6 10 4/16/84 1506 S.0 7.3 13.0 8.7 6.4 10A 4/16/84 1525 2.5 12.1 12.8 9.8 7.4 106 4/16/84 IS)6 4.0 11.0 12.1 9.6 7.2 11 4/16/84 1532
- 2. 5 7.1 12.6 10.2 7.1 12 4/11/84 1217 3.3 14.5 13.3 9.4 1.5 13 4/17/84 1852 4.0 14.2 12.6 9.1 7.5 14 4/17/84 l125 3.0 12.0
- 13. )
9.6 7.3 IS 4/11/84 0848 4.0 14.8 11.2 10.0 7.5 161%
4/17/84 0925 S.0 9.6 12.0 9.8 7.4 17 4/17/84 1010 2.0 20.0 13.3 8.4 1.8 w== m m=== ====a n,mm m m e m m mu-==;== m m m I
h
15 TABLE 9. CONDITION t-woNADS OF TEREDINID BORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM 3ANUARY THROUGH MARCH,1984 EA=Early active; LA= Late active; R= Ripe; PS= Partially spawned; $= Spent; M= Male; F= Female; H= Hermaphrodite Month No. Months Ganad Specimei No.
Station Removed Pupneed Species Sex Condition Comments 1339 o 8
Jan84 6
Bankla gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi M
S d
Bankia gouldi No discernable gonad o
Bankia gouldi F
S 1340 7
Jan84 6
Bankia gouldi M
EA 1341 o 13 Jan 84 6
Bankia gouldi M
EA b
Bankia gouldi No discernable gonad c
Bankia gouldi No discernable gonad d
Bankia gouldi No discernable gonad e
Bankia gouldi F
S 1342 o 14 Jan 84 6
Bankia gouldi F
EA b
Bankia gouldi F
EA e
Bankia gouldi F
EA d
Bankia gouldi F
EA e
Bankia gouldi F
EA f
Bankia gouldi F
EA g
Bankia gouldi F
EA h
Bankia gouldi F
EA I
Bankia gouldi F
EA j
Bankia gould F
S k
Bankia gould.
F EA I
cankia gouldt F
EA 1343 a 12 Jan 84 6
Bankia gouldi M
EA 1344 a 15 Jan 84 6
Teredo navalis F
LA b
Teredo navalis F
LA c
Teredo navalis No discernable gonad 1345 a Jan 84 6
Teredo navalis F
LA b
Teredo navalis M
EA c
Teredo navalis F
LA 1346 a 11 Jan84 6
Bankia gouldi No discernable gonad b
Bankia gouldi No discernable gonad c
Bankia gouldi No discernacle gonad d
Bankia gouldi F
EA e
Bankta gouldi F
EA f
Bankia gouldi No discernable gonad i
i g
Bankia gouldi No discernable gonad h
Bankia wouldi F
S i
Bankta gouldi M
S l
l l
l i
16 TABLE 9. (Continued)
Month No. Months Ganad h+ 'c a No.
Station Removed Exposed Species Sex Condition Comments 1347 2
Jan 84 6
Teredo navalis F
LA 1348 a 17 Jan 84 6
Teredo navalis F
EA b
Teredo navalis M
S Teredo navalis F
LA c
d Teredo navalis M
EA e
Teredo navalis M
EA f
Teredo navalis H
EA g
Teredo navalis H
EA h
Teredo navalis M
S i
Teredo navalis H
EA j
Teredo navalis H
EA k
Teredo navalis H
EA 1
Teredo navalis H
EA 1349 e 17 Jan 84 12 Teredo navalis H
EA Special panel b
Teredo navalis H
EA Teredo navalis M
EA c
1350 a 12 Jan 84 12 Bankia gouldi Special panel; No discernable gonad b
Bankia gouldi F
S Bankia gouldi M
S c-d Bankia gnuidi No discernable gonad 1351 a 11 Jan 84 12 Bankia gouldi M
S Special panel b
Bankta gouldi M
S Bankia gouldi M
S c
d Bankia gouldi F
S e
Bankia gouldi M
EA f
Bankia gouldi M
S Bankia gouldi M
EA g
h Bankia gouldi F
EA i
bankia gouldi M
S j
Bankia gouldi F
S k
Bankia gouldi F
S j
Bankia gouldi F
EA Bankia gouldi M
EA m
Bankta gouldi F
EA n
Bankia gouldi M
EA o
1352 a 7
Jan 84 12 Bankia gouldi Special panel; No discernable gonad b
Bankia gouldi No discerr.able gonad Bankia gouldi No discernable gonad c
1353 2
Feb 34 6
Teredo navalis F
LA 1354 12 Feb 84 6
Teredo navalis F
LA 1355 10A Feb 84 6
Teredo navalis F.
LA
17 TABLE 9. (Continued)
Month No. Months Gened Specimen No.
Station Removed Fwpa==d Species Sex Condition Comments 1356 e 17 Feb 84 6
Teredo navalis M
EA l
b Teredo navalis M
EA c
Teredo navalis M
EA d
Teeedo navalis M
EA o
Teredo navalis M
EA f
Teredo navalis F
LA g
Teredo navalis M
EA h
Teredo navalis M
EA I
Teredo navalis M
EA 1357 10B Feb84 6
Bankia gouldi No discernable gonad 1358 a Feb 84 6
Bankia gouldi F
EA b
Bankia mouldi No discernable gonad c
Bankia gouldi No discernable gonad d
Bankia mouldi No discernable gonad 1359 o Feb 84 6
Teredo navalis F
LA b
Teredo navalis H
LA 1360 12 Feb 84 12 Bankia gouldi Special panel; No discernable gonad 1361 5
Feb 84 6
Bankia mouldi No discernable gonad 1362 c 14 Feb84 6
Bankia gouldi No discernable gonad b
Bankia gouldi No discernable gonad 1363 a 17 Feb 84 12 Teredo navalis M
EA Special panel b
Teredo navalis M
EA c
Teredo navalis M
EA d
Teredo navalis H
EA e
Teredo navalis M
EA f
Teredo navalis M
EA g
Teredo navalis M
EA h
Teredo navalis H
EA 1
Teredo navalis M
, 1364 12 Feb 84 12 Rankia gouldi M
S Special panel 1365 a 7
Feb84 Bankia gouldi Special panel; No discernable gonad b
Bankia gouldi M
S 1366 a 11 Feb 84 12 Bankia gouldi M
S Special panel b
Bankia gouldi M
S c
Bankia gouldi No discernable gonad d
Bankia gouldi M
S e
Bankia gouldi M
EA f
Bankia gouldi M
S g
Bankia gouldi M
EA h
Bankia gouldi M
EA i
Bankia gouldi No discernable gonad
IS TABLE 9. (Continue <0 Month No. Months Gened
--:' :7 No.
Station Removed Exposed Species Sex Condition Comments j
Bankia zouldi M
EA k
Bankia zouldi M
EA I
Bankia mouldi M
EA m
Bankia mouldi M
EA n
Bankia zouldi M
EA o
Bankia mouldi M
EA 1367 a 1
Mar 84 6
Teredo navalis M
EA b
Teredo navalis M
EA c
Teredo navalis M
EA d
Teredo navalis F
EA e
Teredo navalis F
EA f
Teredo navalis M
EA g
Teredo navalis F
EA h
Teredo navalis F
EA i
Teredo navalis M
EA j
Teredo navalis F
EA k
Teredo navalis M
EA I
Teredo navalis M
EA m
Teredo navalis M
EA n
Teredo navalis F
EA o
Teredo navalis F
EA p
Teredo navalis M
EA q
Teredo navalis F
EA r
Teredo navalis M
EA 1368 12 Mar 84 12 Bankia gouldi M
EA Special panel 1369 a 7
Mar 84 12 Bankia gouldi M
EA Special panel b
Bankia gouldi M
EA 1370 a 17 Mar 34 12 Bankia gouldi M
EA Special panel b
M EA 1371 a 17 Mar 34 12 Teredo navalis F
LA Special panel b
Teredo navalis M
EA c
Teredo navalis M
EA d
Teredo navaF-M EA e
Teredo navalis M
EA f
Teredo navalis M
EA g
Teredo navalis M
EA h
Teredo navalis M
EA i
Teredo navalis M
EA j
Teredo navalis M
EA k
Teredo navalis M
EA 1
Teredo navalis M
EA m
Teredo navalis F
LA n
Teredo navalis M
LA
19 TABLE 9. (Continued)
Month No. Months Ganad "i+2x.. No.
Station Rernoved Fvpa==d Species Sex Candition Comments 1372 o 11 Mar 34 12 Bankia mouldi M
EA Special panel b
Bankia gouldt M
EA c
Bankia mouldi M
EA d
Bankia mouldi M
EA o
Bankia gouldi No discernable gonad f
Bankia zouldi M
EA g
Bankia mouldi M
EA h
Bankia zouldi M
S Necrotic 1
Bankia gouldi No discernable gonad j
Bankia mouldi M
EA k
Bankia gouldi M
EA 1
Bankia mouldi F
EA m
Bankia zouldi F
EA n
Bankia gouldi M
EA o
Bankia gouldi F
EA I
l
[
I i
i l
{
-, - _ -