,t I'lilLADICLi'lilA I?l.itCTRIC COMi%NY NUCLEAR GROUP llBADQUARTERS 955 65 Cill!STERilROOK lilND.

WAYNE, PA 19087 5691 (21$) 640 WK)

NUCilAR E.NOtNE1 RINO & $11NICf314J%RTMI:N1 January 23, 1992 Docket IJos. 50-352 50-353 License llos. 11PF-39 11PF-85 U.S. 11uclear Regulatory Commission Attn Document Control Desk Washington, DC 20555

Subject:

Limerick Generating Station, Units 1 and 2

!!RC Safety Evaluation Report Discrepancy Gentlemen:

-This letter is being submitted to inform the IJRC of a discrepancy in its Safety Evaluation Report (SER) for Limerick Generating Station, Units 1 and 2 (i.e., liUREG-0991, " Safety Evaluation Report Related to the Operation of Limerick Generating Station, Ur.its 1 and 2," dated August 1983) regarding the seismic category classification of the new fuel inspection stand.

Specifically, Section 9.1.4 (page 9-9) of the 11RC SER states that l

the new fuel inspection stand at LG5 is designed to moet seismic category I requirements, flowever, Table 3.2-3 and Tabic 9.1-7 of the LCS Final Safety Analysis Report (FSAR) and Updated Final Safety Analysis Report (UFSAR) state that the new fuel 4.nspection stand is classified as seismic l

Category II (i.e.,

non-seismic) and therefore, is not designed to maintain its structural integrity duricg or after a Safe Shutdown Earthquake (SSE).

In addition, there are no regulatory requirements stipulating that the now fuel inspection Stand needs to meet the design requirements of a seismic Category I structure.

Accordingly, we considor that the correct classification of the now fuel inspection atand.is non-coismic.

iv Q'Ob k

)

9202030132 920123 i

PDR ADOCK 05000352 E

PDR

i

,a U.S.'Huclear R3gulatory Commission January 23, 1992

[

Document Control. Desk Pago 2 r

-c i

If you have any questions or require additional information, please do not hositato to contact us.

i l

Very truly yours, 4$h ?

/s G. J'/. Beck Manager Licensing Section r

cc T. T. Martin, Administrator, Region I, US!!RC T. J. Kenny, USNRC Senior Resident Inspector, LCS P

i I

L

.-...,;.... -. ~... ~ -.. - - -. -. -. -..

.;---..,-~...

_...,.,... -.,.. -.. - - -.. -..... - -,.. ~.. - -

-