ADMINISTRAT!vE CONTROLS

,,HIGH RADIATION AREA (Continued) b.

A radiation monitoring device which continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received.

Entry into such areas with this monitoring dev1ce may be made after the dose rate level in the area has been established and personnel have been made_ knowledgeable of them.

c.

A health physics qualified individual (i.e., qualified in radiation i

protection procedures) with a radiation dose rate monitoring device who is responsible for providing positive control over the activities within the area and shall perform periodic radiation surveillance at the frequency specified by the facility Radiation Protection Superintendent-Nuclear in the RWP.

6.12.2 In addition to the requirements of Specification 6.12.1, areas accessible to personnel with radiation levels such that a major portion of the body could receive in one hour a dose greater than 1000 mrems* but less than 500 rads ** shall be provided with l

i locked doors to prevent unauthorized entry, and the keys shall be maintained under the administrative control of the Shift Supervisor on duty and/or health physics supervision / designee. Doors shall remain locked except during periods of access by l

personnel under an approved RWP which shall specify the dose rate levels in the immediate work area-and the maximum allowable stay time for individuals in that area. For individual areas accessible to personnel with radiation levels such that a major portion of the body could receive in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> a dose in excess of 1000 mrems* but less than 500 rads ** that are l located within large areas, such as PWR containment, where no enclosure exists for purposes of locking, and no enclosure can be reasonably constructed around the individual areas, then that area shall be roped off conspicuously posted and a flashing light shall be activated as a warning device. In lieu of the stay time specification of the RWP, direct or remote (such as use of closed circuit TV cameras) continuous surveillance may be made by personnel qualified in radiation protection procedures to provide positive exposure control over the activities within the area.

6.13 PROCESS CONTROL PROGRAM (PCP) 6.13.1 The PCP shall be approved by the Commission prior to implementation.

6.13.2 Licensee-initiated changes to the PCP:

a.

Shall be documented and records of reviews performed shall be retained as required by Specification 6.10.3p. This documentation shall contain:

1.

Sufficient information to support the change together with the appropriate analyses or evaluation justifying the change (s) and

  • Measurement made at 48 inches 30 centimeters from the radiation source of radioacthity.0 i

or from any surface that the radiation penetrates.

    • Measurement made at 1 meter from the radiation source or from any surface that the radiation penetrates.

WATERFORD - UNIT 3 6-23 AMENDMENT NO.68 9508300228 950829 PDR. ADOCK 05000382 P