5 USERS COPY I i} A GEORGIA POWER COMPANY POWER CENERATION DEPARTMENT VOGTLE ELECTRIC CENERATING PLANT TRAINING LESSON P,*808 TITLE:

INTRC' DUCTION TO TECHNIC..L SPECIPICATIONS NUMBER LO-LP-39201-06-C PROGRANt LICENSED OPERATOR TRAINING REVISION:

6 SME RUBIN DATIt 4/19/91 APPROVEDe Df.TE

.g.}f INSTRUCTOR CUIDELINES 1.

LESSON FORMAT A.

Lecture with visuai aids II.

MATERIALS A.

Overhead projestor

% Transparencies C.

White board with markers III. EVALUATION A.

Written or oral exam in conjunction with other lesson plans IV.

REMARKS A.

All Technical Specificationi Interpretations are contained in this Lesson 9201200242 911231 PDR ADOCK 05000424 yy.

S G

PDR e

j i

l Im J V'

4

~

a i

LO LP-39201-06-c

[

i

[

t i

i Licensed operator objectives for this lesson plan can be found in the Licensed r

operator systes Master Plan Section 2.3 (Qualification signotf criteria) l

~!

Latest Revision of cluster Technical specifications 4

Y i

I O

t l

1 4

.)

4 s

q

S t

8' LO-LP-39201-06-C 2NTENTIONALLY LETT BLANK

=

e+

e 3

I t

f LO-LP-39201-06-C RETERENCES:

1.

10CFR50.36 2.

TECH SPECS VEGP UNIT 1 DOCKET No. 50-424 3.

TRANSPARENCIES:

LO-TP-39201-001 OBJECTIVES LO-TP-39201-002 REQUIRED TECH SPEC CATEcoRIES LO-TP-39201-003 TECH SPEC FORMAT LO-TP-39201-004 TORMAT FOR LCOs AND SURVEILLANCE 5 LO-TP-39201-005 TECH SPEC INTERPRETATION REQUEST FORM 4.

Procedure 10000-C 5.

COMMITMENTS Yr 88.028 CYCLE 2 7.5. CHANGE 6.

Technical specifications Interpretatier.s e

e 4

I i

4 LO-LP-39201-06-c LESSON OUTLINas NOTES INTRODUCTION This lesson is designed to familiarise the students LO-TP-39201-001 with where the requirements for having technical specifications ccee from and to teach the format that the technical specifications are arranged in II.

PRESENTATION A.

Requirements for Technical Specifications 1.

Required by 10cFR50.36 Objective 1 a.

Code of Federal Regulations b.

Chapter 10 is Energy c.

Part 50 is the entitled the Domestic Licensing of Production and Utilisation Facilities d.

section 50.36 is Technical specifications 2.

Requires each applicant to submit a draft a.

In accordance with the following section b.

Nust include summary statement of bases or reasons for spec

1) Other than administrative 2)

Shall not become part of specifications 3.

Each license authorizing operation will include technical specifications a.

Will be derived free. evaluation of FSAR-b.

comunission may include those it finds appropriate B.

Will include the following categories (also LO-TP-39201-002 daecribed in 10CTR50.36) 1.

Gafety Limits, Limiting safety system settings a.

safety Limite

1) Definition-operating limits imposed in objective 3 the plant to prevent damage to the fuwl 5

4

__..m__ _ _ _ _ _ _ _. _ _ _... _ _. _ _ _. _____.__ ______._ _ _ _ _

s a

Lo-LP-39201-06 c LESSON OUTLINE:

NOTES cladding ah4 RCS piping and thereby 1

prevent the r.';ase of radioactivity to the environment i

2) protects the fuel cladding by limiting the departure f rom nucleate boiling of the RCS

a. as the departurn from nucleate boiling increases, the heat transfer from the fuel decrsases
b. regulation of DNB is accomplished by limiting RCS Tave for a given RCS pressure 3) protects the Acs piping by limiting ncs pressure-4)

If exceeded, required actione ares i

a)

Reactor shall be shtt down b)

Notify coussission c) submit report - LER d) Not startup until permission from NRC b.

limiting safety System settings i) settings for sutomatic protective devicae

2) Designed to protect aga'. net exceeding safety limite a) Must be set before safety limit is reached l

3)

If protective action does not occur l

a) Take appropriate action which may include shutting down the reactor l-b)

Notify comunission l

c)

Submit report 2.

Limiting Condition for openation l

6

LO*LP-39201-06-c LESSON OUTLINE:

43's a.

Lowest functional cepability or performance level for equipment required for omte operation b.

When LCO not met 1)

Follow the ' ACTION

  • statement of T.8.

a)

If compliance not met within

' ACTION" time, shutdown may be required

2) Notify the commiselon
3) Review the matter and f.ecord the results of the review 3.

surveillance Requirements a.

Requiremente related to test, celibration or inspection b.

Provides assurance that:

1) Necessary quality of systems and Objective 4 componente is mainte,ned 2)

Facility operation will be within the eafety-limite

3) Limiting conditions for Operation will be met
4. Design Features a.

Features of facility whicht

1) Would have a significant affect on safety if altered or modified, or
2) -Are not covered in safety L! mite, Lcos, or surveillances k

Esamples are:

1) NatorialJ of constriction
2) Geometric arrangenets 5.

Administrative controle a.

Provisione necessary to sesure operation of 7

LO-LP-39201-06-c LESSON OUTLINE:

NOTES facility in a safety manner

1) organisetion and management 2)

Procedures 3)

Record keeping

4) Review and audit 5)

Reporting 6)

Initial Notification a) Reporta to cossaission in response to requir:monts of this section C.

Format of Technical specificatione ir Addresses categories of 10crR 2.

Consists of six sections (modified It standard Lo-TP-39201-003 Tech specs /WUREG 1247 modified for Vogtle design)

Objective 2 a.

section 1.0 - Definitions b.

section 2.0 - safety Limite and L8ss c.

section 3.0 - Limiting conditions for Operation d.

Section 4.0 - Surveillence Requirements o.

sectica 5.0 - Design Features f.

section 4.0 - Administrative controls 3.

Lcos and surveilla.n'es presented in combined objective 2 format (sections 3 and 4) a.

LOO appears at top of page b.

Followed immediately by applicable surveillance requirement c.

Combined section 3/4 further subdivided into 12 subsections

1) Reactivity control - Section 3/4.1 LO-TP-39201-004 2)

Power Distribution - section 3/4.1 0

l l

.ah

LO-LP-39201-06-c

~

LESSON CUTLINE:

NOTES 3)

Instrumentation - Section 3/4.3

4) Reacter Jelalt system - Section 3/4.5
5) Emergency Core cooling system -

Section 3/4.5

6) Containeent systems - section 3/4.6
7) Plant systems - Section 3/4.7
8) Electricel systems
  • Section 3/4.C
9) Refueling - section 3/4.9 10) special Test Exceptions -

Section 3/4.10

11) Radioactive Effluents - Section 3/4.11
12) RaGJ1ogic61 Environment Monitcring -

section 3/4.12

d. - Explain'the LCO and surveillance requirements in section 3/4.0 Applicability and give examples of each.

D.

Technical specification clarification objective 5 1.

. Implemented per plant proc.~1ure 10000-c a.

obtain copy of the curtant T.S.

T.s.

-clarifications and review with class clarifications sAct clarification

- controlled copy.

2.

Helps to clear up discrepincies when may be obtained clarification problems arise from the trg ctr library 3.

Tech spec clarification is the responsibility l_

of the operations Department Management.

i

[

4.

Imp 1wentation Procedure a.

When an immediate need exists for an l-clarification, the requestor will centact one of the following individuals who will l:

give a verbal clarification and a written l

request form may follow l-shift superintencent i

9

1 Lo-LP-39201-06-C LESSON OUTLINE:

NOTES Manager operations An operations superintendent b.

If there is not an urgent need for Lo-TP-39201-005 clarification, a for1m contained in 10000-C is used to request a clarification c.

the requestor fille out the first two portions of the clarification form and forwards it to the Manager of operations d.

after the opwrations Manager clarifies, i.he original is placed in the Clarification scok that is maintained in the Control Room E.

Making Changus to Technical Specifications 1.

Licensing Document change Request (LDCR)

Procedure 00402-is generated-a.

Can be done by anyone on site 2.

LDCR must be processed through chain a.

Each individual reviewing LDCR can approve it and send it to next evaluator on disapprove it and return it to previous individual b.

Each LDCR requires safety evaluation c.

.R11 questions must be reviewed cad approved

1) NSAC coordinates changes d.

PRE approval required t

e.

GM approval required i;

f.

NRC reviews documents change III.

SUMMART l-i e

10

LO-LP-39201-06-c LESSON OUTLINs NOTES

1. Define the requirements placed on the plant to have Tech specs.

- Required by 10CTR50.36

2. List and dsscribe the sections and subsections required in Tech specs.

- Consists of six sections (modified W standard Tech specs /NUREG 1247 modified for Vogtle design) a.

Doction 1.0 - Definitions b.

Section 2.0 - safety Limits and Lsss c.

set. tion 3.0 - Limiting conditions for Operation d.

Section 4.0 - surveillance Requirements e.

Section 5.0 - Design Features f.

Section 6.0 - Administrative controla 9

3. Define " safety Limit."

state what the safety Limits are designed to protect.

- Definition-operating limits-imposed on the plant to prevent damage to the fuel cladding and RC* piping and thereby prevent the release of radioactivity to the environment protects the fuel cladding-protects the RCS piping

4. List the assurances that surveillance requirements provide.

- Necessary quality of systems and components is maintained

- Facility operatiou will be within the safety limits

- Limiting conditions for operation will

,be met

5. State how Tech specs interpretations are made.

11

I LO-LP-39201-06-c LESSON OUTLINE NOTES

- I:nplemented per plant procedurs 10000-c

- Implementation Procedure a.

When an issnedtate need exists for an interpretation, the requestor will contact one of the following individuals who will give a verbal interpretation with a follow-up written request form onshift operation supervisor Manager operations Operations Superintendent b.

if there is not an urgent need for interpretation, a form contained in 10000-c is used to request a interprotation O

4 12

1 l

1D.CL.39 06 LICENSED OPERATOR OMECTIVES 14.LP.39201.C I

PURP05E 5TATEMENT Following completion of this lesson, the ste. tent will t ossess those knowledges systematically identified for the performance of the INTRODUCTION TO TECH SPECS tasks.

~

II LI5T OF OBJECTIVE 5 1.

Define the requirements placed cn the plant to have Tech Speen.

2.

List and describe the sections and subsections required in Tech

Specs, 3.

Define ' Safety Limit." State what the Safety Limits are designed to protect.

4 List the assurances that surveillance requirements provide.

5.

State how T.S. clarific.ations are made.

e W

Page 1

F.N CL.39 DidfNff9fMC/TECM ETAFF OLf ECTIVES I

rustro5E ITf.faJan Following completion of this lesson, the student will possess those knowledges systematically identified for the performance of the INTRODUCTION TO TECH SPECS tasks.

II LI3T OF DBJECTIVE3 1.

Define the requirements placed on the plant to have Tech specs.

(Obj ective: 1D.LF.39201 01) 2.

List and describe the sections and subsections required in Tech Specs.

(Obj ective: LO.LP.39201 02) 3.

Define " Safety Limit." state what the safety Limits are designed to protect.

(Objective: 14.LF.39201 03) 4 List the assurances that surveillance requirements provida.

(Obj ective: ID.LP.39201 04) 5.

State how T.S. interpretations are made.

(objective: 14.LP.39201 03)