NRC-84-86 h

WISCONSIN PUBLIC SERVICE CORPORATION P.O. Box 1200, Green Bay, Wisconsin 54305 May 24, 1984 Mr. J. G. Keppler, Regional Administrator Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Keppler:

Docket 50-305 Operating License DPR-43 Kewaunee Nuclear Power Plant IE Bulletin 83-07: Apparently Fraudulent Products Sold by Ray Miller, Inc.

References:

Letter from C. W. Giesler of WPSC to Mr. J. G. Keppler of US NRC dated March 30, 1984 In the above referenced letter we responded to IE Bulletin 83-07.

In that response we f ailed to acknowledge the belated submittal date which was agreed upon with our Resident Inspector. The purpose of this submittal is to acknowledge the date and to revise the attachment to the initial bulletin response.

The attached sheets are submitted as an update to the above referenced letter.

Changes are as follows:

(1) a footnote has been added to line 9 to identify the system as safety-related, (2) information has been added to the remarks section of line 15, and lines 20 through 22, and (3) CMTR, C/PR, and LC have been defined in the legend.

Very truly yours, d.M v

Carl W. 'Gieslerb g Vice President - Power Production 8406050478 840524 JSG/js PDR ADOCK 05000305 Attach.

G PDR cc - Mr. S. A. Varga, US NRC Mr. Robert Nelson, US NRC h

Director, Office of I&E, US NRC gk I t

t i

MATERIAL SUPPLIED TO K WP BY RAY MILLER, INC.

Sheet I of 2 STT"LIrR /VD: DOR RM ERANCH REMARKS ORDERED FROM QTY DESCRIPTION SYST DATE Skokie W.S. Patterson 3

3/4 x 3" Sockolet A182F304 CVC 02-13-76 Sent Me talalloy, Inc.

Skokie Direct W.S. Patterson 3

3/4 x 3" Elbolet A182F304 CVC 02-26-76 Sent Texas Metal Works Kenmore Direct W.S.

Patterson 3

3/4 x 15006 S.W. R.F. Flange A182F31(

CVC 02-12-76 s.Cnarleston Sold to Flowline Corp.

Skokie Ship to W.S. Patterson 2

3" Sch 10 45" LR ELL A403WP304 CVC 08-08-72 West Actual G.W. Taylor Farge Caldwell CMTR W.S. Patterson 1

4x3 Sch 40 Red T A403WP304.04 Min C RHR(1) 03-28-72 West l Check (OK)

G.W. Taylor Forge Caldwell l Analysis W.S. Patterson 1

4x3 Sch 40 Red T A403WP304.04 Min C R"R(1) 03-28-72 Actual ggy lawley Forge Skokie CMTR W.S. Patterson 1

2" 600# R.F. Flange Sch 40 A182F304 RHR PV 03-20-72 act6aA gy)

Hawley Forge Skokie CMTR W.S. Patterson 1

3" 600# R.P. Flange Sch 40 A182F304 FHR RV 03-20-72 Alley Actual S1 Test Stainless Prod.

Skokie CMTR W.S. Patterson 1

2 x 3/4" S.W. Red ELL 90' Sch 160 A182?316 Line (1) 03-19-72 West Actual G.W. Taylor Forge Caldwell CMTR W.S. Patterson 3

3" 90' L.R. ELL Sch 40 A403wP304.04 Min C RHR(1) 03-07-72 Alloy Stainless Prod.

Skokie CA 2 W.S. Patterson 12 3/4" 45' S.W. 2000# ELLS A182F316 CVC 06-27-72 Alloy Actual Stainless Prod.

Skokie CMTR W.S. Patterson 18 2/4 x 1/2 3000# SORD Red T A182F304 INST 06-13-73 Alloy Actual lM.S.Patterson 12 1x 1/2 3000s SCRD Red T A192F304 INST 06-13-73 Stainless Prod.

Skokie CMTR (d.S.Patterson Alloy Actual r

6 1x 1/2 3000s SCRD Red T A182F304 INST 06-13-73 Stainless Prod.

Skokie CMTR C/PR Skokie LC W.S. Patterson 306' 3/8 x.065 SMLS Tubino A211Ti16 INST 06-0A-72 Skokie CA 3 W.S. Patterson 50 3/4 x 1/2 S.W. Inserts 3000# Sch 40 A182F304 MDS 05-17-72 SkoPie CA 3 W.S. Patterson 100 3/4" SCRD Caps 3000# A182F304 MDS 05-17-72 Skokie QA 3 kl.S. Patterson 2

1 1/2" SCRD Caps 3000# A182F304 MDs 05-17-72 f7 [f hj

~~~~~

Skokie QA 3 W.S. Patterson 100 1" SCRD Caps 3000# A182F304.04 Min C MDS 05-17-72 rt M D3

$ {f 0o Skokie C/PR LC W.S. Patterson 1356 3/8 x.065 SMLS Tubing A213T316 INST 04-24-72 Of LJ Skokie C/PR LC W.S. Patterson 305' 1" Sch 80 SMLS Pipe A312T316 Stock 04-23-71

@ [j j)

D=

%J Skokie C/PR LC W.S. Patterson 207' 1" Sch 40 SMLS Pipe A312T316 Stock 04-23-71 Fi

>d uD gj 00 Skokie CA 3 W.S. Patterson 1

2" S.W. Cross 3000# A182F304 CVC 04-17-72 La O

rn V

g.

t.

MATERI AL SUPPLIED '!O IO;PP BY RAY MILLER, INC.

Sheet 2 of 2 SUFPT TERivt.muGR RM BRANCit REMARKS ORDERED FROM QTY DFSCRIPTION SYST DATE Actual-r.eystone Tube Skokie CMTR W.S. Patterson 500 3/8" x.065 SS Tubing A213T116 WD 04-06-72 Skokie OA 3 W.S. Patterson 9

3* 40* 1.R B.W. Ett.S Sch 10 A403WP304 EC9T 04-01-??

~~~~~

Skokie QA 3 W.S. Patterson 4

3" 45' LR B.W. ELLS Sch 10 A403WP304 SOBT 04-03-72 Actual Keystone Tube Skokie CMTR W.S. Patterson 200' 3* Sch 10 SMLS Pipe A312T304 SOBT 03-21-72 Actui Eawley Forge Skokie CMTR W.S. Patterson 1

1" 1500# Blind Flange A182F304.04 Min C Testinc 03-10-72 Skokie CA 3 W.S. Patterson 1

2* Cross S.W. 30004 A182F316.04 Min C CVC 03-09-72 Skokie QA 2 Warren Barr 200' 2* Sch 40 SMLS Pipe A312T334 CVC 09-23-70 Skokie QA 2 Warren Earr 18S' 1* Sch 40 SxLS Pipe A312T304 SFPC 04-08-70 LEGEND:

(1) Safety-related System INST - Instrumentation piping and fittings MDS

- Miscellaneous drains and sumps Stock - Miscellaneous pipang used in instrument and drain piping WO Waste Disposal System SOBT - Steam Generator Blowdown Treatment f7 [f $$

SFPC - Spent Fuel Pool Cooling n n 03

% n n er Do CMTR - Certified Mill Test Report

P La

! k$ d)

.C/PR - Chemical & Physical Report

.p=

ma n,.

IC

- Letter of Compliance

  • c u:

m Oo 0Q C

O m

C'

.__ =