ML20091F025

From kanterella
Jump to navigation Jump to search
Submits Rept Spr 910007 Re Results of Inservice Insp of Steam Generators During Sixth Refueling Outage Listed.Total of 203 Tubes Plugged in Steam Generators A,B & C & 612 Tubes Repaired in Steam Generators A,B & C
ML20091F025
Person / Time
Site: Summer 
Issue date: 11/01/1991
From: Skolds J
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Ebneter S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
SPR-910007, NUDOCS 9111220224
Download: ML20091F025 (1)


Text

,

South Carolina Doctric & Gas Company hhn koMJ Jenkinsvdie, SC 29365 thciear Operahons (603i 345-4D40 SCE&G

.ms_

.0.

1991 u w

' $3 Mr. S. D. Ebneter Regional Administrator U. S, Nuclear Regulatory Comniission Region II, Suite 2900 101 Marietta Street, NW Atlanta, GA 30323

Dear Mr. Ebneter:

SUBJECT:

VIRGIL C. SUMMER NUCLEAR STATION DOCKET NO. 50/395 OPfRATING LICENSE NO. HPF-12 SPECIAL REPORT (SPR 910007)

This Special Report is being submitted pursuant to the requirements of the Viigil C. Tiummer Nuclear Station Technical Specifications. Section 4.4.5.5.a.

This sectian requires a report be submitted, following the completion of o

inservice inspection of steam generator tubes, indicating the number of tubes plugged or repaired in each generator. Summarized in the table below are the results of the inspections performed during the sixth refueling outage.

A B

C Total Plugged 13 21 169 203 Repaired 211 309 92 612 Should you have any questions, please call at your convenience.

Very truly yours, N-John L. Skolds ARR:JLS: led c:

0. W. Dixon Jr.

R. E. Kelso R. R. Mahan Marsh & McLennan R. J. White Document Control Desk General Managers INPO Records Center G. F. Wunder ANI Library C. A. Price NSRC File (ONO 910060)

RTS NRC Resident Inspector (818.C5 & 018.08)

J. B. Knotts Jr.

9111220224 ?11101 ADOCK-0500{g*>

)

DR NUCLEAR EXCELLENCE - A SUMMER TRADITION!

[(./yN t

/

_