p Beaver Valley Po.ser Station Shippmpport PA 15077-0004 (41?) 393-5255 JOHN D. SIEDER v<e PromKlont Nuclear Group l
October 14, 1991 U.
S.
Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555 Subject. Bcavor Valley Powcr Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Eighth Refueling Outage Inservice Inspection Report This' letter forwards the Inservice Inspection Ninety-Day report on ASME Class 1,
2,-
and 3
components sxamined during the eighth refueling. outage at Beaver Valley Unit No.
1.
The ASME Boiler and Pressure Vessel
- Code,Section XI, Article IWA-6230 requires that an inservice inspection report be submitted to the enforcement and regulatory authority having jurisdiction at the plant site within ninety days after completion of an inservice inspection.
The recent inservice inspection term at Beaver Valley Unit No. 1 ended on July 15, 1991.
These examinations are part of Interval 2, Period 2 of the Unit No.
1 ISI inspection schedule.
The inservice inspections were performed in accordance with Section XI of the ASME Boiler and Pressure vesse' Code, 1983 edition through Summer 1983 addenda.
If you have any questions, please contact Steve Sovick at (412) 393-5211.
Sincerely,
(
.4 L'
r--
(. D.
S er Attachment cc:
Mr. J. Beall, Sr. Resident Inspector Mr. T.
T.
Martin, NRC Region I Administrator Mr. A. W.
DeAgazio, Project Manager Mr. M.
L. Bowling (VEPCO) 9110290192 911014 PDR ADOCK 05000334 k\\
O PDR i.