Text

.___

l' i

t.

8405290165 840521 TABLE 3,13-1 SHEET 2 l'

PDR ADOCK 05000250 l

P PDR SAFETY RELATED SNUBBERS - UNIT 3

~-

Snubbers Snubbers Snubbers Approximate Snubbers in High Especially Inaccessible Accessible FPL Elevation Radiation Areas Difficult to During Nermal During Normal Tag No.

System (Feet)

Durina Shutdown

  • Remove Operation Operation 25 Pressurizer Relief 73 X

X 26 Pressurizer Spray 73 X

X 27 Pressurizer Spray 73 X

X 23 Pressurizer Spray 73 X

X 29 Pressurizer Spray 73 X'

X 30 Pressurizer Relief 73 X

X 31 Pressurizer Relief 73 X

X 32 3A S/G Blowdown in Cubicle 32 X

33 3A S/G Blowdown in Cubicle 32 X

34 3A S/G Blowdown in Cubicle 32 X

35 3C S/G Blowdown in Cubicle 33 X

36 3C S/G Blowdown in Cubicle 33 X

i 37 3C S/G Blowdown in Cubicle 21 X

l 38 Residual Heat Removal 2

X X

39 Residual Heat Removal 2

X X

40 Residual Heat Removal 2

X X

41 Residual Heat Removal 2

X X

42 Safety Injection 12 X

X 43 44 45 46 Steam to Aux. Feedwater 26 X

3 47 Steam to Aux. Feedwater 26 X

48 Steam to Aux. Feedwater 26 X

4 Amendment Nos. _. and..

L

TABLE 3.13-1 SHEET 3a SAFETY RELATED SNUBBERS - UNIT 3 Snubbers Snubbers Snubbers Approximate Snubbers in High Especially L e essible Accessible '

'FPL System (Feet)

During Shutdown

  • Remove Operation Operation Elevation Radiation Areas Difficult to During Normal During Normal Tag No.

95 "A" RTD Loop 22 X

X 96

' "A" RTD Loop '

22 X

X

-97 "A" RTD Loop 19 X

X 98 Excess Letdown Line 15 X

99 "A" RCP CCW Line 23 X

X l

l 100 "A" RCP CCW Line 23 X

X 101 "A" RCP CCW Line 23 X

X 102 "A" RTD Loop 27 X

X 103 "A" RTD Loop 23 X

X 104 105 Excess Letdown Line 15 X

106 "C" RCP Seal Return 37 X

X 107 CCW to C RCP Cooler 30 X

X 108 CCW to C RCP Cooler 32 X

X 109 CCW to C aCP Cooler 22 X

X 110 "B" RTD Loop 26 X

X 111 "B" RTD Loop 27 X

X 112 Cont. Spray Pump Room 19 X

113 RWST Line 19 X

114 RWST Line 19 X

.115 Charging Pump Room 26 X

116 14" RWST Line in Pipeway 12 X

X 117 14" RWST Line in Pipeway 12 X

X 118 14" RWST Line in Pipeway 12 X

X Amendment Nos. __ and.

Y TABLE 3.13-1 SHEET 3b SAFETY RELATED SNUBBERS - UNIT 3 Snubbers Snubbers Snubbers Approximate Snubbers in High Especially Inaccessible Accessible FPL Elevation Radiation Areas Difficult to During Normal During Norma! '

Tag No.

System (Feet)

During Shutdown

  • Remove Operation Operation 119 12" RWST Line in Pipeway 12 X

X 120 RHR Heat Exchanger Room 28 X

X 121 RHR Heat Exchanger Room 24 X

'. X 122 RHR Heat Exchanger Room 7

X X

123 RHR Heat Exchanger Room 5

X X

124 RHR Heat Exchanger Room 5

X X

q s

Amendment Nos.

and

STATE 0F FLORIDA

)

)

ss.

COUNTY OF DADE

)

C. O. Woody, being first duly sworn, deposes and says:

That he is Vice President Nuclear Operations of Florida Power & Light Company, the licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said 4

Licensee.

b. 0, UoveAt /

C. O. Woody Subscribed and sworn,to before me this d

d e of

' I d(/-

, 1984.

r undM didh )

NOTAR PUBLIC, in d for the County of Dade, State of Florida.

My commission expires:

Y k?lt " " C" ^fWra-a u r, im

"^ '" : 4

.a w. w, g,; ;, y o

l l

.,