DUKE POWER GOMPANY P.O. HOx 33180 CHAMLOTTE, N.C. 28242 f", "
p MA % 10,0i9k6 M ='
Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 Re: Catawba Nuclear Station Units 1 and 2 Docket Nos. 50-413 and 40-414 Dear Mr. O'Reilly In.ny letter of May 4,1984, a completion date of May 11, 1984 was given for corrective action required by Significant Deficiency No. 413-414/84-07. Corrective action for Unit 2 will not be complete by the May ll,1984 date. This is due to other Unit 1 fabrications which are receiving higher priorities at this time.
Unit 2 work on the subject deficiency will be complete by August 1,1984.
Very truly yours, hb-
/h1(J Hal B. Tucker LTP/php cc: Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 NRC Resident Inspector Catawba Nuclear Station Palmetto Alliance 21351 Devine Street Columbia, South Carolina 29205 INP0 Records Center Suite 1500 1100 Circle 75 Parkway Atlanta, Georgia 30339
)
Mr. Robert Guild, Esq.
Attorney-at-Law P. O. Box 12097 Charleston, South Carolina 29412 OppygyE COPY r4o5240007 e40511 PDR ADOCK 05000413 Tc 21 4 0
.