AO-50-219/75-06:on 750310,stack Gas Sample Sys Failed to Continuously Monitor Stack Releases While Reactor in Unisolated Condition.Caused by Circuit Design.Request to Modify Circuit for Stack Gas Sample Pumps Submitted
ML20090D780
Person / Time
Site: Oyster Creek
Issue date: 03/19/1975
From: Ross D
JERSEY CENTRAL POWER & LIGHT CO.
To: Anthony Giambusso
Office of Nuclear Reactor Regulation
References
AO-50-219-75-06, AO-50-219-75-6, NUDOCS 8303020359
Download: ML20090D780 (3)


Text

r.-

geg,u.u t._ fa.,

..~. ~f0 e'

~

,[~]

p Jersey Central Power & Light Company MADISON AVENUE AT PUNCH BOWL ROAD

  • MORRISTOWN, N. J. 07960
  • 201-539-6111

,.n or r,,,

f "E**

Public Utilities Corporation General g

,K

, nr, e./

c,.

.x O,

\\ l'h 3

/..)'7.

j' March 19, 1975

~ - in ' *. C x

/

,4,

~v,

- f.,

~

. f

.yr

. ~.

g N

g I'

Mr'. A. Giambusso Tl

4 P 9 - ' O:

Director, Division of Reactor Licensing N

N

Office of Nucicar Reactor Regulation

(.3 4'}

United States Nuclear Regulatory Commission Washington, D.-C.

20545

,s

Dear Mr. Giambusso:

L_"f;c ~

a

Subject:

Oyster Crcok Station Docket No. 50-219 Abnormal Occurrence Report No. 50-219/75-6 The purpose of this letter is to forward to you the attached abnormal occurrence report in compliance with paragraph 6.6.2.a of the Technical Specifications.

Enclosed are forty copics of this submittal.

Very truly yours, A

m Donald A. Ross, Manager Generating Stations-Nuclear es Enclosures cc:

Mr. J. P. O'Reilly, Director Office of Inspection and Enforcement, Region 1 8303020359 750319

{DRADOCK 05000219 D//

PDR

.; h' O

O Jersey Central Power & Light Company MADISON AVENUE AT PUNCH BOWL ROAD

  • MORRISTOWN, N.J. 079ti0
  • 201-539-6111 unusan w rus General

{e,e Public Utihties Corporation sysrs =

OYSTERCREEKNUCLEARGENERATINGSTATION,,,,,,._/, LdCl !I 0

%. :. r1-FORKED RIVER, NEW JERSEY 08731 nQiL.C JJ.

l Abnormal Occurrence Report No.'50-219/75-6 Report Date March 19, 1975 Occurrence Date March 10, 1975 Identificatien cf Occurrence Violation of the Technical Specifications, paragraph 3.6. A.3,(failure of the stack gas sample system to continuously monitor _ stack re.1 cases _while the reactor swM an, unit 51~ated con ~di'tioiG_)"This ~6vW: is considered to be an abnormal occurrence as defined in the Technical Specifications, paragraph 1.15B.

Conditions Prior to Occurrence The plant was operating at steady-state power with major parameters as follows:

Power:

Core, 1882 FMt Electric, 660 MNe 4

Flow:

Recirculation, 16.0 x 10 gpm 6

Feedwater, 7.50 x 10 lb/hr Reactor Pressure:

1020 psig Stack Gas:

34,225 pei/sec Description of Occurrence At 1125 on March 10, 1975, an operator was dispatched to the boiler house to change over from the "B" stack gas sample pump to the "A" pump.

Since it had been reported that the "A" pump was losing oil, the intent was to operate this pump long enough for maintenance personnel to troubleshoot. Noting that the "A" pump was extremely noisy upon starting, the operator advised the shift foremen of this condition.

The shift foremen, in turn, dispatched an assisting

p 1

ty.

=

'., e J

Abnormal Occurrence Report No. 50-219/75-6 Page 2 shift foreman to evaluate the prob 1cm. The "A" stack gas sample pump sub-sequently tripped off while the assisting shift foreman was checking out the pump. The assisting shift foreman immediately attempted to restart the "B"

pump; however, the pump failed to start. lie then reset the thermal overload (common to both' stack gas sample pumps) and switched back to the "A" pump.

The "A" stack gas sampic pump started at this time.

While the "A" pump operated, it was noted that flow was low (about I cfm), and that vacuum was higher than normal.

Consequently, the assisting shift foreman started the "B" stack gas sample pump.

The total amount of time during which neither stack gas sample pump was operating was less than one minute.

Apparent Cause of Occurrence The cause of the failure of the "B" stack gas sample pump to start following the trip of the "A" pump is considered to be circuit design.

The existing circuit provides just one thermal overload for both pumps.

Consequently, a trip of one pump on thermal overload requires the manual resetting of the thermal overload before the other stack gas sample pump can be started.

Analysis of Occurrence A review of the stack gas radiation monitor recorder traces showed the Icvels of both monitor channels to be relatively constant (at 900 cps) before and after this event.

In a further effort to determine if excessive stack releases might have occurred during the approximate period that neither stack gas sample pump was operating, recorder traces of radiation monitoring systems associated with two gaseous streams released through the stack were reviewed.. A review of the off gas radiation monitor recorder traces showed that the IcVels of both monitor 3

channels were relatively constant (at approximately 2.0 x 10 mr/hr) with no spiking for a period of approximately 60 minutes prior to this event.

Sixty minutes is the approximate off gas system holdup time prior to releasing to the stack.

In addition, a review of the reactor building ventilation exhaust radiation monitor recorder traces showed that at the time of this event, the levels of both monitor channels were relatively constant (at approximately 1.5 mr/hr) with no spiking.

Based on these considerations and the very short period of time that neither stack gas sample pump was operating, the safety significance of this event is considered te be minimal.

Corrective Action An engineering request will be submitted to Generation Engineering to modify the electrical circuit for the stack gas sa.nple pumps.

"A" stack gas sampic pump will be disassembled, inspected, and reassembled in order to determine the cause of its tripping the thermal overload.

Failure Data i

Previous abnormal occurrences involving the stack gas sample pumps:

1.

Abnrrmal Occurrence Report No. 50-219/74-53 2.

Abnormal Occurrence Report No. 50-219/74-54 3.

Abnormal Occurrence Report No. 50-219/74-57 4.

Abnormal Occurrence Report No. 50-219/74-61 i