Dose & Curie Corrections for 1988-1990
ML20090B423
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 12/31/1990
From:
CENTERIOR ENERGY
To:
Shared Package
ML20090B330 List:
References
NUDOCS 9203030388
Download: ML20090B423 (12)


Text

-___ - _______ _.

Dose and curie Corrections 1988 - 1990 The following data tabulations include changes to the SRERRs submitted from 1988 to 1990 as a result of the inoperable flow monitor for the Turbine Building / Heater Bay ventilation system (LER 91-012).

1988 Quarter 1 - No corrections 1988 Quarter 2

. Attachment 1 Radiological _ Impact on Han.(Dose Summaries)

Summary of. Maximum-Individual Doses from To

-Iodine & Particulates (mrem) 4.53E+00 4.76E+00 Population Doses Total Body-(rem)

N/A Thyroid (rem)

N/A Radiological Impact on-Man (Land Based Sectors) from To Iodine & Particulates (mrem) 3.40E+00 3.53E+00 Gaseous Effluents Iodines from To-Total Iodine 131 (Ci) 3.37E-02 3.75E-02 Avg. Release Rate (uCi/sec) 4.29E-03 4.77E-03 Isotopes (Ci) 1133 l'.79E-02 2.13E-02 Onsite doses for Gaseous Effluents from To Total Body (mrem)

N/A t

l Organ (mrem) 4.9E-01 7.6E-01 9203030388 901231 PDR ADOCK 05000440

.R PDR

_ _ _. _. _ _ _ _ _. _. _. _. ~ _ _ _ _ _

i Dose and curie Corrections 1988 - 1990 1988 Quarter 1 & 2 Radiological Impact on Man (Dose Summaries) 1 Summary of Maximum Individual Doses From To Iodine & Particulates (mrem) 4.56E400 4.79E+00 Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Dased Sectors)

From To Iodine & Particulates (mrem) 3.40E+00 3.53E+00 Gaseous Effluents Iodines From To Total Iodine 131 (Cl)

N/A See individual quarters Avg. Release Rate (uCi/sec)

Isotopes (Ci)

Onsite doses for Ganeous Effluents from To Total Body (mrem)

N/A Organ (mrem) 4.9E-01 7.6E-01 1988 Quarter 3 i Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To Iodine & Particulates (mrem)

N/A Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors)

From To Iodine & Particulates (mrem)

N/A Gaseous Effluents Iodines From To Total Iodine 131 (Ci) 6.65E-03 6.73E-03 Avg. Release Rate (uCi/sec) 8.37E-04 8.46E-04 Isotopes (Cl)

Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A organ (mrem) 9.9E-02 1.6E-01 n

-..,-m._,

.._,.__.,,.__,__.-_.,_.~.mm

._.,_..,,,_,.-..,_._,,,_,,.,.__-m..__m

- _,.m__._.---_

_.--.-.,,,,,--..v_

_ m., -. m m _--,....,,-.-

Dose and curie Corrections 1988 - 1990 1988 Quarter 4 - No Corrections i

i 1988 Quarter 3 & 4

> Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses from To

. Iodine & Particulates (mrem)

M/A Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors)

Prom To Iodine & Particulates (mrem)

N/A Gaseous Effluents Iodines From To Total Iodine 131 (Ci)

N/A Avg. Release Rate (uCi/sec)

Isotopes'(Ci)

Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A Organ (mrem) w

-- - =

orv,,,-.,--+,n-,-..-,-,-+-,,,v,-,.,-v-w v.

m %,

.,v--~=,-w-.-%-my,<-w.-w,w.,r,w,-,,ww,--....-ww wv.-,.-

e w

-,g--,

c-=.-e n,-

myy-++.,e

Dose and Curie Corrections 1988 - 1990 1988 YEAR Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses rrom To Iodine & Particulates (mrem) 6.19E+00 6.42E+00 Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors)

From To

)

Iodine & Particulates (mrem) 4.55E+00 4.67E+00 Gaseous Effluents Iodines from To Total Iodine 131 (C1)

N/A Avg. Release Rate (uCi/sec)

N/A Isotopes (Ci)

Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A Organ (mrem) 6.7E-01 1.0E400 i

1989 Quarter 1 - No Corrections l

1 Y

--,-.-.ve..,

--..-.vr-m.w

-e,-

-,v=m-


r--'- - - - - - - = - - ' - - - - - " - ' - - - - " ' -

Dose and Curie corrections 1988 - 1990 1989 Quarter 2 - No-Corrections 1989 Quarter 1 &

2-- No Corrections l

1:

~,. -, ~, - -.. - - -,

- - ~ - -

--- ~ ~-~ - - ' ~ ' ' '

- ~ - ~ ~ '

' ~ ~ ~ * " ~ ^ ' * '

Dose and Curie corrections 1988 - 1990 1989 Quarter 3 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To Iodine & Particulates (mrem) 5.68E-03 5.86E-03 Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors)

From To Iodine & Particulates (mrem) 4.43E-03 4.45E-03 Gaseous Effluents Iodines From To Total Iodine 131 (Ci)

N/A Avg.-Release Rate (uCi/sec)

N/A Isotopos (C1) 1133 4.38E-05 5.21E-05 Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A Organ (mrem)

N/A 1989 Quarter 4 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To Iodine & Particulates (mrem) 2.87E-02 3.03E-02 Population Doses Total Body (rem)

N/A Thyroid (rem) 9.8E-03 1.0E-02 Radiological Impact on Man (Land Baseo

tors)

From To Iodine & Particulates (mrem) 1.39E-02 1.54E-02 Gaseous Effluents Iodines From To Total Iodine 131 (C1) 8.74E-04 8.84E-04 Avg. Release Rate (uCi/sec) 1.10E-04 1.11E-04 Isotopes (Ci) Il33 1.33E-03 1.36E-03 Onsite doses For Gaseous Effluents From To Total' Body (mrem)

N/A Organ (mrem) 7.4E-03 1.1E-02

Dose and curie Corrections 1980 - 1990 1989 Quarter 3 & 4 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses from To Iodine & Particulates (mrem) 3.42E-02 3.59E-02 Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors) from To Iodine & Particulates (mrem) 1.83E-02 1.98E-02 Gaseous Effluents Iodines rrom To Total Iodine 131 (Ci)

N/A Avg. Release Rate (uCi/sec)

N/A Isotopes (C1)

Onsite doses for Gaseous Effluents from To I

Total Body.(mrem)

N/A Organ (mrem) 7.1E-02 7.4E-02 1989 YEAR Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses from To Iodine & Particulates (mrem) 1.79E-01 1.80E-01 Population Doses Total Body (rem)

N/A Thyroid (rem)

N/A Radiological Impact on Man (Land Based Sectors) from To Iodine & Particulates (mrem) 3.58E-02 3.73E-02 Gaseous Effluents Iodines from To Total Iodine 131 (C1)

N/A Avg. Release Rate (uC1/sec) _

N/A Isotopes (Ci)

Onsite doses for Gaseous Effluents from To Total Body (mrem)

N/A Organ (mrem) 7.7E-02 9.6E-02

-. ~.

.,. _ ~,_. _,. _ _,,. _, _. _. -.. -

Dose and Curie _ Corrections 1988 - 1990 1990 Quarter 1 - No corrections l

l 1990 Quarter 2 Attachment i Radiological Impact on Man (Dose Summaries) l Summary of Maximum Individual Doses i

From To Iodine & Particulates (mrem) 2.04E-01 2.46E-01 Population Doses Total Body (rem)

N/A Thyroid (rem) 6.4E-02 7.4E-02 Radiological Impact on Man (Land Based Sectors)

From To Iodine & Particulates (mrem) 8.61E-02 1.03E-01 Gaseous Effluents Iodines From To Total Iodine 131 (Ci) 2.62E-03 3.17E-03 Avg. Release Rate (uci/sec) 3.33E-04 4.04E-04 Isotopes (Ci) I133 4.95E-03 5.75E-03 l

l Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A l

Organ (mrem) 2.82E-02 3.2E-02 l

l

. -. _. ~

_ = _-. - -.~.

Dose and curie corrections 1988 - 1990 1990 Quarter 1 & 2 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To

odine & Particulates (mrem) 2.20E-01 2.61E-01 Population Doseh Total Body (rem)

N/A Thyroid (r">)

7.2E-02 8.2E-02 Radiological Impact on Man (Land Based Sectors)

From To Iodine & Particulates (mrem) 9.25E-02 1.09E-01 Gaseous Effluents Iodines From To Total Iodine 131 (Cl)

N/A Avg. Release Rate (uci/sec)

N/a Isotopes (Ci)

Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A Organ (mrem) 5.1E-02 5.5E-02 1990 Quarter 3 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To Iodine & Particulates (mram) 1.07E+00 1.23Ev00 Population Doses Total Body (rem)

N/A Thyroid (rem) 2.7E-01 3.0E-01

' Radiological Impact on Man (Land Based Sectors)

From To Iodine & Particulates (mrem) 6.94E-01 7.BBE-01 Gaseous Effluents Iodines From To Total Iodine 131 (Cl) 5.13E-03 5.87E-03 Avg. Release Rate (uci/sec) 6.46E-04 7.39E-04 Isotopes (Ci) 6.24E-03 7.40E-03 Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A Organ (mrem) 1.2E-01 1.4E-01 l

n

.-s,.,

n a

w

Dose and Curie Corrections 1988 - 1990 1990 Quarter 4 -'No Corrections

.1990 Quarter 3 & 4 Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses from To Iodine & Particulates (mrem) 1.07E+00 1.23E+00 Population Doses Total Body (rem)

N/A Thyroid (rem)_

2.7E-01 3.0E-01 Radiological Impact on Man (Land Based Sectors) from To Iodine & Particulates (mrem) 6.94E-01 7.88E-01 Gaseous-Effluents Iodines From To Total Iodine 131-(C1)

N/A Avg. Release Rate (UCi/sec)

N/A

. isotopes (Cl) i Onsite doses For Gaseous Effluents From To Total Body (mrem)

N/A

-Organ (mrem) 1.3E-01 1.5E-01

e v

Dose and curie corrections 1988_- 1990 1990 YEAR Radiological Impact on Man (Dose Summaries)

Summary of Maximum Individual Doses From To Iodine & Particulates (mrem) 1.25E+00 1.46E+00 Population Doses Total Body (rem)

N/A Thyroid (rem) 3.4E-01 3.9E-01 Radiological Impact on Man (Land Based Sectors) from To Iodine & Particulates (mrem) 7.84E-01 8.95E-01 Gaseous Effluents Iodines From To Total Iodine 131 (Ci).

N/A Avg. Release Rate (uCi/sec)

N/A Isotopes (Ci)

Onsite doses For Gaseous-Effluent.c from To Total Body (mrem)

N/A Organ (mrem) 1.5E-01 1.8E-01 i

-,