f 's D A LTIMORE GAS AND ELECTRIC

^

/

CHARLES CENTER e P.O. ouX 1475

  • BAl.TIMORE, M ARYL AND 21203 1475 R E DENTON GENf.% M%AGER CAivEHfCt H S February 26,1992 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATI~ENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Annual Report of Power-Operated Relici and Safety-Valve Failures and Challenges for the January 1 through December 31.1991 Period Gentlemen:

We are submitting this report in accordance with Calvert Cliffs Technical Specification 6.9.1.5.c. Tbc report descriacs challenges to, and failures of, Power-Operated Relief (PORV) and Safety Valves.

Two PORVs actuated in 1991.

The first actuation occurred on June 5,1991. Uni: 1 PORV 1-ERV-404 lifted while at COLD SHUTDOWN (MODE 5) with the reactor coolant system depressurized and vented. This occurred while a technician was installing a control-circuit jumper as part of a Surmillance Test Procedure (STP). Ile accidentally shorted the jumper to a power supply terminal during installation. This caused the power-supply fuse to fail and the PORV to actuate.

On June 21,1991, while performing an STP at MODE 5, Unit 1 PORV 1-ERV-402 cycled rapidly several times. This occurred when a jumper, which had a stray wire strand, was shorting to ground.

The PORV leaked by its seat as a result of this rapid cycling. The PORV was intentionally cycled once, shortly aftc : test completion to stop the leakage.

These events were investigated as part of our correctise action program. Appropriate corrective action was taken in both instances.

Should you have any questio", regarding this matter, we will be pleased to discuss them with you.

)urs,

?

M i

RED /REF/ref/bjd cJ:u.I"'L Q((073743M l

Q3noiosv2o22s 76't?

i R

ADOCK 05000317

//O em 1

f a

Document Control Desk I'ebruary 26, lW2 l' age 2 cc:

D. A. lirune,liquire J. IL Silberg, thquite it. A. Capra, NitC D. G. McDonaki, Jr., NitC T. T. hlas tin, NitC l',11. Wilson, NitC 11.1. hiclean, DNil J. I1. Walter, PSC l

l l

l

!