FLORIDA POWER & LIGHT COMPANY March 29, 1984 L-84-82 Mr. Janes P. O'Reilly Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, GA 30303

Dear Mr. O'Reilly:

Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 IE Bulletin 83-08 Florida Power & Light has reviewed IE Bulletin 83-08 (Electrical Circuit Breakers With an Undervoltage Trip Feature in Use in Safety-Related Applications Other Than the Reactor Trip Systen).

In response to the bulletin FPL reviewed all safety-related circuit breakers at Turkey Point Units 3 & 4 and found no breakers, other than reactor trip switchgear, which utilize an undervoltate trip attachment.

This completes FPL's action on this bulletin. Should you or your staff have any questions on this information, please contact us.

Very truly yours, i

J. W. Willi ans, Jr.

Vice President Nuclear Energy JWW/PLP/js Att achment c'c: Document Control Desk, USNRC Harold F. Reis, Esquire PNS-LI-84-111 8404060187 840329 PDR ADOCK 05000250 G

PDR I

PEOPLE.. St.RViNG PEOPLE m

- s STATE OF FLORIDA

)

ss.

COUNTY OF DADE J. W. Williams, Jr., being first duly sworn, deposes and says:

That he is Vice President of Florida Power & Light Company, the licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

J. W. Willi ans, Jr.

Subscribed and sworn to before me this M day of

[/fld

, 1984.

L

. /N t$,

l v, -

3 NOTARY PUBLIC, in #nd for the County of Dade, State of Florida.

My commission expires:

POWY PU;Uc Sun ori1CCdUf~@

diY CCMMissioN (@ld PLC 41984 O UW h lil5 e UlCLAWElJERS

-