n KANSAS GAS AND ELECTRIC COMFANY THE ELECTAC COMPANY OLENN LMOESTER vcr pers.csNT. Nucttan March 16, 1984
@ MOW 2 V I
Mr. J.E. Gagliardo, Acting Chief L
Reactor Project Branch 2 g
U.S. Nuclear Regulatory Commission f bb Region IV g
[
j 611 Ryan Plaza Drive, Suite 1000 JL Arlington, Texas 76011 KMLNRC 84-032 Re:
Docket No. STN 50-482 Ref: 1) Letter KMLNRC 83-034 dated 3/25/83 from GLKoester, KG&E, to WCSeidle, NRC
- 2) Letter KMLNRC 83-060 dated 5/26/83 from GLKoester, KG&E, to WCSeidle, NRC
- 3) Letter KMLNRC 83-093 dated 7/18/83 from GLKoester, KG&E, to WCSeidle, NRC
- 4) Letter KMLNRC 83-138 dated 10/21/83 from GLKoester, KG&E, to JEGagliardo, NRC
- 5) Letter KMLNRC 84-010 dated 1/31/84 from GLKoester, KG&E, to RPDenise, NRC Subj: Withdrawal of Potential 10CFR50.55(e) -
Welds on Bergen-Paterson Sway Struts
Dear Mr. Gagliardo:
On February 24, 1983, Kansas Gas and Electric Company (KG&E) reported a potential 10CFR50.55(e) matter concerning welds on Bergen-Paterson sway struts and additional information was subsequently provided in References 1) through 5). The evaluation of the welds in question have now been completed and KG&E has determined that welds would not have adversely affected safety of operations had they gone uncorrected.
Therefore, KG&E has concluded that this matter is not reportable pursuant to 10CFR50.55(e).
Please contact me or Mr. Otto Maynard of my staff if you have any questions concerning this subject.
Yours very truly, pfl/
GLK:bb cc: RCDeYoung WSchem
,9 (
8403270163 840316 gDRADOCK 05000482 Il O PDR I
201 N. Market - Wichita, Kansas - Mail Address:Mu. cua s.~, Wichita, Kansas 67201 -Telephone: Area Cods (316) 261-6451