ML20087K404

From kanterella
Jump to navigation Jump to search
ISI Summary Rept Cycle-8 Refueling Outage
ML20087K404
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 08/10/1995
From:
SOUTHERN CALIFORNIA EDISON CO.
To:
Shared Package
ML20087K401 List:
References
NUDOCS 9508230273
Download: ML20087K404 (447)


Text

{{#Wiki_filter:_ h 1 C 1 SAN ONOFRE NUCLEAR GENERATING STATION l UNIT 2  ! O I i i INSERVICE INSPECTION

SUMMARY

REPORT CYCLE-8 REFUELING OUTAGE l AUGUST 10,1995 ( -

                                              ...r, 9508230273 950816 PDR  ADDCK 05000361                                                                   -

O PDR i l

g . SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT  : i UNIT 2 1 OF 16 . t _, y: r i s I (s. L TABL.E OF CONTENTS i t SECTION- PAGE = I 1 Introd u ction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Pl an & S ch edule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 i

  ,                 3    Summary Report . . . . . . . . . . . . . . . . . . . . . .         ............. . .............. ..                          .............4 Refuelling Outage Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5                                      j Form NI S- 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6          _;

Abstract of Examinations & Tests... .................................... 8 i Abstract of Results of Examinations & Tests............. ..... .... 9 Ab stract of Corrective Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 i 4 Abstract of NIS-2 Repair & Replacements........... .........................11 , 1 5 pd NDE R e cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -. - . . . . . . . . . NDE Proced ures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . 12 i Personnel Certifications... .... ..... . . .. ...... . .. . . . ..... . .. ... .... ... . . . . . .. .. 13 i; i 6 ISI Procedures & Travelers (CWO's)............................ ................14 i 7 Augm ent e d Exammations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 t 8 Steam Generator Exammations.............. ........... ............................. 16 1 4 ATTACHMENTS  : t 9 List of Completed ISI NDE Examinations and System Pressure Tests l 10 Form NIS-2 Owner's Reports For Repairs OR Replacements  ! t i T I I i I

       '                                                                                                                                                                                           [

y,. SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2 2 OF 16 i l 1 INTRODUCTION This document refers to the implementation of the Inservice Inspection (ISI) conducted at the San Onofre Nuclear Generating Station (SONGS) Unit 2 for the 1 40-year life of the plant from August 18,1983 thru August 18,2023. Inspection Program B which uses a four 10-year intervals has been adopted by SONGS. These 10-year intervals are shown below: 1st Interval August 18,1983 thru August 17,1993 2nd Interval August 18,1993 thru August 17,2003 3rd Interval August 18,2003 thm August 17,2013 4th Interval August 18,2013 thru August 17,2023 Each 10-year Interval is further divided into 3 periods which is adjusted to j accommodate 2 refueling outages in each period. Adjustments of the intervals to i accommodate these refueling outages is allowed by the code to extend or decrease the interval by as much as 1 year. These extension was used in the 1st 10-year interval which ended in March 1994. The 1st and 2nd 10-year intervals are: 1st Interval August 18,1983 thru March 31,1994 2nd Interval April 1,1994 thru August 17,2003 The 3 periods for the 2nd 10-year interval are as follows: PERIODS DATES OUTAGES _ 1 Apr 1,1994 - Aug 17,1997 U2C8, U2C9 2 Aug 18,1997 - Aug 17,2001 U2C10,U2Cl1 3 Aug 18,2001 - Aug 17,2003 U2Cl2,U2Cl3 ASME Code Section XI, Anicle IWA-6000, Records & Reports, the ISI Program Plan Doc. # 90063 Rev 1 and the ISI procedures were used to put this report together. This repon is intended to provide a summary of the ISI activities performed during the Unit 2 Cycle 8 outage. Detailed descriptions of these activities are documented, controlled and maintained in accordance with the Owner's Technical Specification commitments. J

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT  ! ,. UNIT 2 3 OF 16 p

  .jy                                                                               ,

wj t o 2 PLAN & SCHEDULE , CLASS CATEGORY TOTAL PERIOD PERIOD PERIOD EXAMS REQUIRED 1 2 3  ; 1 B-A 27 3 3 21

  • B-B 10 2 3 5 B-D 34 6 8 20 i B-E 55 18 18 19 '

B-F 28 8 10 10  ! B-G-1 264 87 87 90 B-G-2 163 53 53 57  ! B-H 2 1 0 1 B-J 191 62 63 66 i B-K-1 10 3 3 4 B-L-1 2 0 0 2 B-L-2 1 0 0 1 ( L]- B-M-1 B-M-2 8 11 2 3 3 4 4 3 1 i B-N-1 3 1 1 1 B-N-2 30 0 0 30-B-N-3 2 0 0 2 - B-O 36 0 0 36 B-P Each Refueling Outage B-Q Per Tech Spec 2 C-A 15 3 '6 6 C-B 16 3 6 7 C-C 57 18 18 21 C-F-1 220 72 72 76 C-F-2 31 9 10 12 C-G 5 1 2 2 C-H Each Inspection Period 3 D-A 12 3 3 6 D-B 91 25 26 40 D-C 21 5 6 10 IWF F-A 270 86 89 95

g SAN ONC FRE NUCLEAR GENERATING STATION -

SUMMARY

REPORT . UNIT 2 4 OF 16 lv' . 3

SUMMARY

REPORT

                       . Date of Document Corpletion.................. . ..................... August 10,1995                   -

Name & A.ddress of Owners: Southern California Edison San Diego Gas & Electric Co. 2244 Walnut Grove Ave. 101 Ash St. Rosemead, CA 91770 San Diego, CA 92112 City of Anaheim City ofRiverside

     .                 Public Utilities Department                                  Public Utilities Department City Hall West - lith Floor                                  3900 Main St.

O 201 S. Anaheim Bivd. Anaheim, CA 92805 Riverside, Ci 92522 Name & Address of Generating Plant: San Onofre Nuclear Generating Station . 14000 Basilone Road,4 Miles South of San Clemente San Clemente, CA 92522 Number Designation of the Unit.... .......................................... ....... Unit 2 Commercial Service Date for the Unit..... ..... ................. August 18,1983 0

L S AN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT ., UNIT 2 5 OF 16 _[') REFUELING OUTAGE NO. E i t i Refueling cutage Number: I O l U2C8 1 I l e I l l 1 O l 1 l

                                    .g . .    -     .   .        -      - - -       -      - -.. ,      .-           .    .- -,-

i z SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2 6 OF 16 I

    ,.   'g i

j '

                                . FORM NIS-1. OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules l

1 i

1. Owner: Southem Califomia Edison Company i 2244 Walnut Grove Avenue, Rosemead, CA 91770
2. Plant: San Onofre Nuclear Generating Station l 14000 Basilone Road,4 Miles South of San Clemente  :

4 San Clemente, CA 92674-0128 j

3. Plant Unit: 2 4. Owmer's Certificate of Authorization: N/A
                                                                                                                                        )
5. Commercial Service Date: 8/18/83 6. National Board Number for Unit: N/A l
7. Components Inspected.

mmmmmmmmmmmmmmme imummmmmmmmmmmmmm imummmmmmmmmmmme imummmmmmmmmmmen .- Component Manufacturer Manufacturer State or National

                                                                                                                                        ]

or or orInstaller . Province Board  ; Appurtenance Installer Serial Number Number - Number O Reactor Vessel 2MV1101 Combustion Engineedng 71170 N/A- 22000 Steam Gen Combustion 2ME088 Engineenng 71270-2 __ 35203-82 22219-Steam Gen Combustion 2ME089 Engmeermg 71270-1 35203-82 -22218 Pressurizer Combustion -] 2ME087 Engineering 70602 N/A 21495 l Reactor Coolant Pump 2MP001 Byron Jackson 701-N-0558 N/A N/A Reactor Coolant Pump 2MP002 Byron Jackson 701-N-0559 N/A N/A Reactor Coolant Pump 2MP003 Byron Jackson 701-N-0560 N/A N/A l 1 Reactor Coolant i Pump 2MP004 Byron Jackson 701-N-0557 N/A N/A Letdown Heat Combustion , Exchanger ME062 Engineedng 78826 , N/A 10781

   ' SAN ONOFRE NUCLEAR GENERATING STATION                                                          

SUMMARY

REPORT UNIT 2 7 OF 16 , n V FORM NIS-1 (back) r

8. Examination Date April 1.1994 to Anril 22.1995 >
9. Inspection Period Identification: X lst Period 2nd Period 3rd Period
10. Inspection Interval: 1st 10-Yr12nd 10-Yr 3rd 10-Yr 4th 10-Yr
11. Applicable Edition of Section XI... ...............................1989 Edition. No Addenda
12. Date/ Revision ofInspection Plan. .... ....... . October 1.1993 Doc # 90063. Rev 1
13. Abstraet of Examination & Test.......... .......................... ....... . ........ ..See page 8 j
14. Abstract of Results of Examinations & Tests- See page 9
15. Abstract of Corrective Measures:.......... . ............. ............ ......... ...See page 10 We certify that a) the statement made in this report are correct, b) the examinations and tests .

meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures  ! taken conform to the rules of the ASME Code, Section XL Certificate of Authorization No. N/A Expiration Date: N/A I Date 8//0 19 ffSigned Southern California Edison By N ) (Owner) Mpiager, Site Technical Services O _ i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of California and employed by Arkwright Mutual Insurance Company

    &actorv Mutual Engineerine Association) ofNorwood. Massachusetts have inspected the components described in this Owner's Report during the period _ April 1.1994 to Aue.17.1995 and state that to the best ofmy knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. p m Commissions fgM AA BOD;lME, 'N~Y Inspector's S' ignature / NB, State, Province or Endorsements Date 8h // 19 95' O "

SAN ONOFRE NUCLEAR GENERATING STATION '

SUMMARY

REPORT l UNIT 2 8 OF 16 l t.

  ]}

ABSTRACT OF EXAMINATIONS & TESTS This report covers the inservice examination activities conducted at the San Onofre Nuclear Generating Station (SONGS), Unit 2. This activity is one of the two that are scheduled for the 1st period of the 2nd 10-year interval as described i in the ISI Program Plan Doc. 90063, Rev.1. The inservice examinations were l . , . conducted in accordance with the of the ASME Boiler and Pressure Vessel Code -  ! Section XI, 1989 Edition No Addenda. In addition to the surface (PT & MT) and visual examinations (VT-1,3) performed [ by SCE Quality Control Inspectors on components outside the containment, the -  ! services of outside NDE vendors were also employed. The services of NDE  : Levels-I, II & III (UT, PT, MT, & VT) were contracted to and provided by  ! Lambert, MacGill, Thomas, Inc. while additional VT Level-II services were l provided by Volt.  ! A ISI Visual Examinations (VT-2) performed in conjunction with the Reactor Coolant System pressure test was performed by both SCE and Volt VT Level-II examiners. List of examinations and tests are included in appendix A. i Arkwright Mutual Insurance Company (Factory Mutual Engineering Association)'  ! provided the services of the Authorized Inspection Agency (AIA) Authorized Nuclear Inservice Inspector.s (ANII's). l t P I O  : I f l

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORTL UNIT 2 9 OF 16 h y ABSTRACT OF RESULTS OF EXAMINATIONS & TESTS The inservice and preservice examinations conducted at SONGS 2 were performed between 4/1/94 and 4/30/95. This examination was performed to fulfill the requirements of 10CFR50.55(G)(4) and IWA-1400, Owner's Responsibilities of ASME Code Section XI,1989 Edition, No Addenda. The number of components and supports for Class 1,2 and 3 selected for examination was based on the ISI Program Plan Doc. # 90063, Rev. I employing-Inspection Program Plan B of the ASME Code Section XI,1989 Edition, No1 Addenda. This code edition also employs the Mandatory Appendix VII which - requires qualification of NDE personnel for UT examination. Qualification of UT personnel includes a blind test by demonstrating the ability to find flaws on test specimens. The 1989 Edition, No Addenda of Section XI also expanded the scope

         .of examination by including components and their connections down to over NPS .

1-1/2. These change necessitated the fabrication of additional UT calibration - blocks. The Reactor Coolant System pressure test was performed with all insulations . removed on pressure retaining bolted connections which is also a requirement of-ASME Code Section XI 1989 Edition, No Addenda. 242 welds were scheduled for volumetric examination,256 for surface, and a total I of 100 for a combined VT-1 and VT-3. Of those welds scheduled for examinations,228 welds were examined by UT,256 by surface exam PT or MT and 94 by VT-1 and VT-3. The difference in numbers is attributed to those , components whose scheduled examinations were deferred to the next refueling I outage due to ALARA or cost. However, the number ofwelds or components required by ASME Code to be inspected per Period, has to be met by Cycle 9. ) All other NDE examinations were found acceptable with no relevant indications. .t

P SAN ONOFRE NUCLEAR GENERATING STATION SUhBLMWREPORT I' UNIT 2 - 10 OF 16 ~l(~) u.)  : 1 ABSTRACT OF CORRECTIVE MEASURES  ! A VT-3 visual examination of a sway strut pipe suppon reported 3 loose bolts out- ' of 4 that holds the support base plate. A nonconfonnance report (NCR  : 9501004000) was generated to document and disposition this condition. The  ! disposition of the nonconformance was " rework". The nuts were tightened and -  : retorqued. As a result of this condition, the number of supports to be inspected . l was expanded as required by the code. Two more adjacent supports were selected j and inspected with no relevant conditions.  ! During a VT-3 visual examination of the reactor pressure vessel interior, a weld - was suspected of having insufficient throat dimension (underfill). This initiated a l nonconformance report (NCR 9503005800). After a detailed additional l examination with more light, no relevant conditions were found. The { nonconformance report was dispositioned " accept as-is". l o 1 k f e 3 0

i

                ! SAN ONOFRE NUCLEAR GENERATING STATION         

SUMMARY

REPORT UNIT 2 11 OF 16 e

         /\,

1,U-  ! ( 4 ABSTRACT OF NIS-2 REPAIRS & REPLACEMENTS -  !

                                                                                   *b k

O l 1 i e O 4 e

 ~,s--

8/09/95 Unit 2 cyclo 8 Page 1 Abstract of Records of Repairs and Replacements Mo Traveler EQID class NIS-2 Worksun (~~>') ........... .......... ...................... ..... ........ .................................................. 1 None SO2 86-110 080-10289 III 1 6/13/94 Replaced torq carriers, pinoin gear i 2 None S02 86-112 S2ST001H007A III-1 6/13/94 Replaced torg carriers, pinoin gear, cylinder 3 None 502-86-114 S2ST001H0078 III-1 6/13/94 Replaced torq carriers, pinoin gear  : 4 None 502-86-121 080-10289 III-1 6/13/94 Replaced torq carriers, pinoin gear l 5 None 502-86-125 080-10289 III-1 6/13/94 Replaced torq carriers, pinoin gear, cylinder 6 None S02-86-127 080 10289 III 1 6/13/94 Replaced telescroping cylinder 7 None $02-86-134 080-10289  !!!-1 6/13/94 Replaced inertie mass, torq carr, cylinder, gear 8 88062545001 024 26435 III 2 6/15/94 Repaired valve plug 9 90062403003 S21204MR040, 2-51-139- III-2 6/27/95 Replaced valve 00A 10 91041131001 S02-91-032 521204MR171 III-2 5/05/94 Modified SI vent line, added valve 11 92040105000 $21204MUO73 III 1 8/09/95 Replaced hinge pin cover botting 12 92061092002 S21208MW247 III 2 8/15/94 Rebuilt accumilator 13 92072166002 SA1513MU393 III-2 2/18/94 Replaced valve, downstream pipe nipple 14 92090930000 S21204MUO15 III 2 6/27/95 Replaced' valve disc 15 92091550001 2FV0203 III-2 6/13/94 Replaced valve plug 16 92101023002 $21208MU01S III-2 8/06/95 Replaced tennet 17 92101793000 2PSV9320 III-2 2/01/94 Replaced disc, spring, washers, spindle 18 92110881000 2PSV9225 III-2 1/06/94 Replaced nozzle, disc, spring, washers . 19 93013671000 $21204MR352 III-2 2/15/94 Replaced valve bonnet 20 93040963000 025-83508 III-2 4/03/95 Replaced valve disc 21 93051202000 $21204MUO18 111-1 8/09/95 Replaced hinge pin cover bolting 22 93051203000 $21204MUO19  !!I 1 8/09/95 Replaced hinge pin cover botting G 23 93051204000 $21204MUO21 III 1 8/09/95 Replaced hinge pin cover botting

 )  24 93051205000               $21204MU155           III-2 6/26/95 Reptoced hinge pin cover botting 25 93051206000               S21204MUO17           III-2 6/26/95 Replaced hinge pin cover botting 26 93051207000               S21204MUO40           III-1 8/09/95 Replaced hinge pin cover botting 27 93051208000               S21204MUO41           III-1 8/09/95 Replaced hinge pin cover botting 28 93051209000               S21204MUO43           III 1 8/09/95 Replaced hinge pin cover bolting 29 93060988000               025-21680             III 2 8/06/95 cannibatized bonnet, performed hydro 30 93072001000               S21212MU294           III-2 8/04/95 Replaced valve disc 31 93080054000               $21206MR017           III-2 8/01/95 Replaced disc 32 93080073000               S21212MU296           III-2 8/06/95 Replaced disc & bonnet 33 93080076000               2PSV9215              III 2 8/01/95 Replaced valve 34 93080093000               S21212MR219           III-2 8/04/95 Replaced valve disc 35 93090873000               2HVB419               !!I-2 1/17/94 Repaired bonnet drain Line 36 93100171000               027-66749             III-2 12/28/93 Repaired damaged stud hole threads 37 931002 % 001              S21301MU1000          III-2 8/04/95 Replaced valve 38 93100519000               2HV4048               III-2 7/13/95 Replaced tube connector 39 93101071001               S21208MU107           III-2 12/28/93 Replaced valve dise 40 93110109000               S21301MU637           III 2 7/31/95 Seplaced valve 41 93111177000               2NV6569               III-2 2/16/94 Rework solenoid valve 42 93111180000               2HV6570               III-2 2/16/96 Rework solenoid valve 43 93111843000               2HV6569               III-2 2/16/94 Performed hydro 44 94010417000               2HV8419               III-2 8/04/95 Replaced valve plug 45 94011452000               025-83508             III-2 7/13/95 Replaced valve internals 46 94020429000               S21301MU1257          III-2 8/04/95 Replaced valve 47 94020694001               S21204MUO74           III 1 8/09/95 Replaced hinge pin cover botting 48 94020697000               S21204 MUD 42         III-1 8/09/95 Replaced hinge pin cover botting                          ,

49 94020858001 521204MUO75 III 1 8/09/95 Replaced hinge pin cover botting / ] j Q 50 94021405000 2HV9204 III-1 8/01/95 Replaced valve plug l l l

8/09/95 t$it 2 Cycta 8 Page 2 Abstract of Records of Repairs and Replacements m i  ; M0 Traveler EQID Class NIs-2 Worksua

 \ ~j        ........... .......... ...................... ..... ........ ..................................................

51 94031297000 2PSV9226 III-2 4/03/95 Replaced valve 52 94040946000 521201MP001 III-1 8/01/95 Replaced pump seat cartridge 53 94041244001 521201MP003  !!I-1 8/01/95 Replaced pump seat cartridge 54 94050237001 2P18204M, 2PsL8204 III 2 4/03/95 Replaced instr iso valves, tube /etbows 55 94050508001 2HV9324 III-2 8/01/95 Cut / reseal-welded body to bonnet ' 56 94050922000 2PSV0200 III-1 8/01/95 Replaced valve, intet studs & nuts 57 94050942000 2PSV0201  !!!-1 8/01/95 Replaced valve, intet studs & nuts 58 94051480000 2PSV8401 III-2 7/31/95 Replaced valve & intet nuts 59 94C51485000 2PSV8402 III-2 7/31/95 Replaced valve & inlet nuts 60 94051486002 521208ME062 III-2 8/07/95 keplaced studs & nuts 61 94051487000 2PSV8404 III-2 7/31/95 Reptaced valve & inlet nuts 62 94051488000 2PsV8406 III 2 7/31/95 Replaced valve & inlet studs 63 94051489000 2PSV8407 III 2 7/31/95 Replaced valve & intet studs 64 94051492000 2PSVB416 III-2 7/31/95 Replaced valve & inlet studs 65 94052031001 2HV8204 III 2 8/03/95 Replaced valve nut 66 94052378000 s21101MV001 III-1 6/09/95 Installed modified reactor head vent spool S21201MU995, MLD58 67 94052571000 2Pv0100B III 1 8/06/95 Replaced @ per bonnet assembly, nuts 68 94060552001 521208MR320 (MW247) III 2 4/07/95 Replaced instrument line & valve 69 94061023000 521204MR292 III 2 8/01/95 Replaced valve disc 70 94061026000 s21204MR095 III-2 6/26/95 Replaced disc & bonnet 71 94061068000 S21208MR320 (MW247) III-2 4/07/95 Machined adapter for sW prep 72 94061280000 s21208MW219 III-2 4/07/95 Replaced valve stem fm 73 94062923000 S21208MF020, III-2 6/26/95 cvCS ultrafiltration, vendor feb . filter internals (* ) 74 94070315000 531208MF020 2PSV9349 III-2 6/27/95 Replaced valve 75 94071412001 s21208ML007, III 2 6/06/95 Material verification and prefab 1204MLO48,052,050 76 94071416000 s21301MUO20 III-2 7/31/95 Replaced valve & pipe nipple 77 94071419000 521208MU216 III-2 6/06/95 Material verification and pre-fab 78 94071537000 S2Cs019H009 III-2 5/18/95 Stubber deletion 79 94071543000 s2S1050H003 III 2 5/18/95 Replaced srshber w/ rigid strut 80 94071544000 s2sI052H010 III 2 5/18/95 Srmeber detetton 81 94071550000 s2RC027H004 III-2 5/18/95 Srshber/ spring can deletion, rept srabber w/ strut. 82 94071579000 S21206MR082,ML008, III-2 6/15/95 Added new lines & drain valves MR083,MR009 83 94071581000 s21206MR080,ML006, III-2 6/15/95 Added new lines & drain valves MR081,MR007 84 94080194000 52CC287H009 III-2 4/03/95 snubber deletion 85 94080195000 52CC287H011 III 2 4/03/95 Replaced srnbber w/ rigid str"t 86 94080278000 52CC275H008 III 2 4/03/95 Snubber deletion 87 94080282000 $2CC275H009 III-2 4/03/95 Replaced snubber w/ rigid strut 88 94080283000 $2RC073H031  !!I-2 4/04/95 srabber deletion 89 94080284000 52RC073H038 III-2 4/03/95 Replaced snubber w/ rigid strut 90 94080324000 s2SIO77H006, H008, III-2 4/03/95 snubber deletions N019 91 94080325000 s2s!077H012 III-2 4/03/95 Replaced snubber w/ rigid strut 92 94080388000 s2VC008H004,7,11,S2VC0 III-2 4/03/95 snubber deletions 59H005 p 93 94080390000 $2VC008H029 III-2 4/03/95 Replaced snubber w/ rigid strut (j 94 94080391000 52VC008H001 III 2 4/03/95 Replaced u-bolt w/ pipe guide

a 1 8/09/95 Unit 2 Cyclo 8 Page 3 i Abstract of Records of Repairs and Replacements

   )         M0          Traveler EQID                       Class NIS 2     Worksta V            '........... .......... ...................... ..... ........ .................................................. i 95 94080394000             52VC008H042              III 2 4/04/VS P1pe sulde de!etion 96 94080395000             528M037H004              III-2 4/04/95 Replaced srnJbber w/ rigid strut 97 94080491000             52Fs057H075              III 2 4/03/95 Replaced srnbber w/ rigid strut 98 94080494000             5275057H074              III-2 4/03/95 spring hanger deletion 99 94080498000             52VC012H007              III 2 4/04/95 snubber deletion 100 94080499000             52VC003H019E W           III-2 4/03/95 Replaced snubbers w/ rigid struts 101 94080596000             $2sID21HD11,14,17,21,2 III-2 4/03/95 SrmJbber deletions 3,31 102 94080597000             52sI146H004N-s, H005     III-2 4/03/95 snubber deletions 103 94080956000              52sIO21H013             III 2 4/03/95 spring support oeletion
  • 104 94080999000 52VC058H035 III 2 4/03/95 Pipe guide deletion 105 94081017000 521201MR042 III-2 12/23/94 Replaced downstream ttbe-fitting (DOWNSTREAM) 106 94081166000 s21212MR073 III 2 8/07/95 Replaced valve disc 107 94081552000 S2s!048H004, 007, III-2 4/03/95 srabber deletions 003, 186H001 l 108 94031553000 s2sID53H003 III 2 4/03/95 Replaced snubber w/ rigid strut 109 94081555000 s2sI185H001 III-2 4/03/95 Replaced snubber w/ rigid strut 110 94081654000 52sIO48H002 III-2 4/03/95 Installed pipe guide 111 94081661000 52sIO49H011 III-2 4/04/95 Installed pipe guide 112 94081662000 52sI185H002  !!!-2 4/04/95 Pipe stop, mounting plate deletion 113 94081687000 52sIO14H012, H018, III-2 4/03/95 Snteber deletions H021 g 114 94081688000 $2sIO14H019 III-2 4/04/95 Replaced stubber w/ rigid strut

('j 115 94081689000 52sIO21H002A-B III 2 4/04/95 Replaced srubbers w/ rigid struts , 116 94082002000 s2sIO83H0AE III 2 4/03/95 Replaced stubber w/ rigid strut f 117 94082003000 52Cs003H011, 053A-6, III 2 4/03/95 Srmbber deletions 063A-B 118 94082005001 52Cs003H061 III-2 4/03/95 Replaced rigid strut 119 94082007000 52Cs003H065B-T III 2 4/03/95 Replaced snubbers w/ rigid struts l 120 94082017000 52Cs003H041 III 2 4/03/95 srabber deletions j 121 94082019000 52Cs003H043 III-2 4/03/95 Replaced stabber w/ rigid strut ' 122 94082020000 s2Cs003H044 III-2 4/07/95 Replaced armbber w/ rigid strut  ! 123 94082021001 52Cs003H046A III-2 4/03/95 Replaced snubbers w/ rigid struts l 124 94082022000 52Cs003H047 III 2 4/03/95 Replaced stubber w/ rigid strut I 125 94082256000 52sID38H116 III-2 8/04/95 Added new pipe support assenbty 126 94082257000 52VC008H039A-B III 2 4/03/95 Replaced arabbers w/ rigid struts l 127 94082258000 s2VC104H019A-8 III-2 4/03/95 Replaced srabbers w/ rigid struts { 128 94082321000 521208MLD07, III 2 6/06/95 Adjed vent valve for IST s21208MR671 129 94082323000 521208MR050, III-2 6/06/95 Modify line, add valve, replace valve 521208MLI216,MLD98 130 94082325000 $21204MLO48, III-2 6/06/95 Added vent valve for IST S21204MR446 131 94082326000 $21204MLD52, III-2 6/06/95 Modified line, added vent valve for IST S21204MR445 f 132 94082327000 521204MLD50, III-2 6/06/95 Added drain valve for IST l 521204MR447 1 133 94082421000 52sT002H026 III-2 4/04/95 Replaced snubber w/ rigid strut l 134 94082425000 52sT002H013A-B III-2 4/04/95 spring can deletions j

  ) 135 94082528000                52sT002H041, H046       III-2 4/04/95 snubber deletions                                      I

l l 8/09/95 Unit 2 Cyclu 8 Page 4 Abstract of Records of Repairs and Replacements j i

             )       MO          Traveler EQID                      Class WIs-2      Workaum s   _j         ........... .......... ...................... ..... ........ ..................................................     -

136 94082529000 52sT002H040 III-2 4/03/95 Replaced snubber w/ rigid strut, lugs 137 94082530000 52sT002H042 III-2 4/03/95 Replaced snthber w/ rigid strut, tugs 138 94082532000 52sT002H047. III-2 5/04/95 Replaced snubber w/ rigid strut 139 94082566001 2P!4048M N/A 7/13/95 Replaced valve, elbows, tubing 140 94090086000 s2Fs107H006 III 2 4/04/95 Replaced snubber w/ rigid strut 141 94090088000 S2Fs107H007A-B III 2 4/03/95 Replaced snubbers w/ rigid struts 142 94090173000 s21301ME088 III-2 5/18/95 Replaced hand hold stud & nut 143 94090289000 521301ME089 III-2 5/18/95 Replaced secondary handiole studs & nut 144 94090490000 521301ME088P III.1 8/04/95 Replaced manway studs & nut 145 94091025001 2F00296, s21201MU995, III-1 6/09/95 Modified reactor head vent spoot, valve added

  .                                         MLD58 146 94092057001             s21206ML006,ML007,ML00 III 2 6/15/95 Material verification and prefab 8,MLOO9 147 94100193000             521204MUO73             III-1 6/23/95 Cuts all-thread for hinge pin cover studs 148 94100582001             521301ME088             III-2 5/18/95 Replaced aanway cover stud & nut 149 94100692000             521301ME089P            III-1 8/04/95 Replaced manway stud & nuts 150 94100709000             $21220Mx015             III 2 5/09/95 Rewelded wear plate to fuel transfer tube 151 94110421000             521206MR080,ML006,      III 2 6/15/95 Tubing tie-ins, sigports MR081,MLOO7 152 94110424000              S21206MR082,ML008,      III 2 6/15/95 Tibing tie-ins, steports MR083,MLOO9 153 94110491000              s2-1305-ML-187         III-2 6/09/95 Fab'd garaan plugs 154 94110658000              s2130$ML190            !!I-2 6/09/95 Fab'd gasmia plugs (qV) 155 94111649001             s21305ML189, 2-FW-189- III-2 6/09/95 Repaired feedwater line cracks 5, -6 156 94111654001             52130$ML190, 2-FW-190- III-2 6/09/95 Repaired feedwater line cracks 5, -6 157 94120052000             2PSV9207, S21208ML111 III-2 6/06/95 Deleted valve and capped pipe 158 94120179001             S21208MF020             III-2 6/26/95 CVCs ultrafiltration, installed mod & vt-2 159 94120187000             521208MUO73             !!!-2 6/06/95 Check valve internals permanently deleted 160 94120362000             521208MF020             III-2 6/26/95 CVCs ultrafiltration, vendar machining of housing 161 94120373000             52-PREFAB, s21208MF020 III-2 6/26/95 CVCS ultrafiltration, prefab cover arpurtenance 162 94120446001             521301MR11,5            III-2 8/01/95 Replaced pipe-to-tthe adapter 163 94120695001 S21212ML004             III-2 7/13/95 Removed valve, capped line 164 94121829000             2PSV8154                III 2 7/31/95 Replaced spring w/ washers & spindle 165 95010533000             CLOSURE BOLT PRE-FAB    III-2 6/26/95 CVCs ultrafiltration, welded washer to closure bolt 166 95010620001             521208MUO17            III-2 8/01/95 Replaced disc and cover 167 9502015800G             2HV6216-               III-2 7/13/95 Replaced flange botting 168 95020801000             2PSV9226               III-2 7/31/95 Replaced valve
  • 169 95020807000 S21201MR074 III-1 6/26/95 Replaced disc 170 95020822000 521208MR119 III-2 8/01/95 Replaced valve disc 171 95020881000 521201MUO21 III-1 8/08/95 seat welded body to bonnet 172 95020882000 S21201MUO21 III 1 8/08/95 Replaced disc & cover 173 95021078000 2PDT0123 VALVE III-2 8/01/95 Replaced valve manifold, tubire MANIFOLD 174 95021158000 52ss037H006 III-2 5/04/95 Replaced load stud w/ load pin 175 95021160000 $2sT018H041 III 2 5/04/95 Replaced load stud w/ load pin 176 95021212000 52RC149H00C III-2 5/04/95 Replaced load sttd w/ load pin 177 95021213000 s2sIO74H002 III-2 4/04/95 Replaced load pins

(] t / 178 95021216000 179 95021301000 52ss042H010, H021 52ss072H00Y III-2 6/09/95 Replaced load studs w/ load pins III-2 5/04/95 Replaced snubber V

,~ 8/09/95 Unit 2 Cycto 8 - Page 5 Abstract of Records of Repairs and Replacements r

p. '
       )        No           Traveler E0!D                       Class N!s 2 - Workstan

_ . (d. k? 180 95021302000 52sT014H041 III 2 6/09/95 Replaced arm &ber 181 95021465000 ~ 52sIO66H030 III-1 6/09/95 Replaced armeber + 182 95021485000 $21201ME087 III 1 8/01/95 Replaced manway studs & nuts  ; 183 95021534001 2HV9348 III-2 8/06/95 Repelred segment seating surface ' 184 95021577000 s2sIO43H0188 III 1 4/18/95 Replaced snubber r 185 95021655000 82RC147H0018 T '!!I 1 7/13/95 Replaced snubbes 186 95021661000 521901MU573 III-2 5/18/95 Replaced valve cover, disc 187 95021798000 $2s!165H006 III-1 6/09/95 Replaced arm &ber 188 95021927000 52sIO74H002 III 2 6/09/95 Replaced arm &ber 189 95021980000 2NV0517 III-2 8/07/95 Reptoced valve plus 4 190 95030412000 52SIO64H030 III-1 8/04/95 Replaced enubber 191 95030474000 521208ME062 III 2 8/07/95 Cut all thread into studs 192 95030517000 52-Cs-003-H-061 111-2 4/03/95 Replaced load pins 193 95030543000 82sID64H004 III-1 T/13/95 Replaced snubber ' 194 95030584000 52sIO45H028E III-1 5/04/95 Replaced snubber 195 95030819000 521104CEDM III-1 8/07/95 Welded the housins nut 196 95030863000 2PSV0201 (REF) III-1 8/01/95 Machined flange surface 197 95030958000 522418MU002 III-2 6/26/95 Replaced disc & cover l 198 95031173000 821301ME088  !!!-2 6/06/95 Repaired safe end nozzle 199 95031254000 s2RC031H001 III 1 6/09/95 Replaced snubber 200 95031256000 s2ss042H021 III-2 6/09/95 Replaced snubber 201 95031302000 2-RC-152-D III 2 8/01/95 Replaced flange studs & nuts i 202 95031348000 521305ML190 III-2 5/18/95 Removed linear indication on elbow l gs 203 95031365000 2PT0101-3 III-2 8/03/95 Replaced tihe & tube fitting ( \ 204 95031389000 s2sT016H013 III-2 6/09/95 Replaced erm&ber 205 95031402000 $2sT002H026 III-2 4/04/95 Replaced toed pin 206 95031529001 2PSV0201 III-1 8/01/95 Machined intet seating surface 207 95031606000 521201MR038 III-1 7/13/95 Replaced tube & time fitting 208 95031738000 522423Mu248 III 2 8/06/95 Replaced disc 209 95031944000 52FW190H014T III 2 7/13/95 Replaced arm &ber , 210 95031945000 s2FW190H018E III-2 7/13/95 Replaced snubber ' 211 95031946000 52FW190W018W III 2 7/13/95 Replaced arm &ber 212 95040023000 2LT1125-1 N/A 5/04/95 Replaced 3 directional clamp 213 95040851000 2PSV9388 III-2 7/31/95 Replaced valve 214 95041301000 521201MP003 III 1 8/04/95 Reptoced 2 seat heat exchanger / driver mount studs 215 95050587001 2PV0100A III-1 8/08/95 Reassembled valve, vt2 216 95050588001 2PV01008 III-1 8/07/95 Replaced upper bonnet assembly 217 95050593000 2PV0100A III-1 8/08/95 Installed / seat welded pipe caps 218 95050594000 2PV01006 III-1 8/07/95 Instatled/ seat welded pipe caps l 219 95050673000 2NV9433 III-1 7/13/95 Capped / seat welded pecking tenk-off line l ASMEMO.R1 l

                                                                                                                                      )

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2 12 OF 16

 - /

5 NDE RECORDS NDE PROCEDURES: SO23-XXVII-20.28 Ultrasonic Evamination of Reactor Vessel Flange Stud Hole Threads SO23-XXVII-20.47 Magnetic Particle Exammation SO23-XXVII-20.48 Liquid Penetrant Exanunation SO23-XXVII-20.49 Visual Exanunation Procedure to Determme the Condition of Nuclear Parts, Components and Surfaces SO23-XXVII-20.50 Visual Evamination Procedure for the Evidence of Leakage SO23-XXVII-20.51 Visual Examination Procedure for Operability of Nuclear Components and Supports and Conditions Relating to their Functional Adequacy SO23-XXVII-20.52 UT Examination of Nozzle Inner Radius Areas SO23-XXVII-20.53 UT Examination of Tidekness Measurement C/ SO23-XXVII-20.54 UT Examination of Nuclear Cooling System Ferritic Piping SO23-XXVII-20.55 UT Examination of Nuclear Cooling System Austenitic Piping SO23-XXVII-20.56 UT Flaw Sizmg SO23-XXVII-20.57 UT Examination of Steel Forged Bolts & Studs,2" and Greater in Diameter. SO23-XXVII-20.58 UT Examination of Ferritic Steel Welds Using Time-of-Flight l Diffraction Method i SO23-XXVII-20.59 Planar Size Characterization to ASME Section XI Code Requirements SO23-XXVII-20.60 Permanent Weld Marking i SO23-XXVII-20.61 Preparation of the "ADAhf' System l SO23-XXVII-20.62 Evaluation & Analysis of UT C-Scan Data Using ADAM Plus UT Imaging System SO23-XXVII-20.63 UT of Reactor Coolant Pump Flywheel

,m.        SO23-XXVII-20.66  UT of Vessel Welds & Adjacent Base Metal                                 ;

/ \  ! '%_) l l

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT , UNIT 2 13 OF 16 ([  !. ' NDE PERSONNEL CERTIFICATION RECORDS F_D.E NAMES METHOD LEVEL Cert Eve Test Lambert MacGill & Thomas, Inc. Al Whealdon PT, MT, UT III X X VT-1,2,3,4 III X X Scott Erickson MT, PT III X X VT-1,2,3,4 III X X UT II X X Jeffrey Devers MT I X X VT I 'X X PT,UT II X X Quirino Loredo UT, PT, MT II X X ( VT-1 II X X Mark Seiwald ET I X X MT, PT, UT II X X Charles McElroy UT, PT, MT II X X l VT-1,2,3 II X X Norvel Bollingmo UT II X X . l Jeffrey Johnson UT, PT, MT II X X VT-2,3,4 II X X VOLT , Bany Seaholts l ( Certified under l SCE program ) VT-1,2,3,4 II X X Southern California Edison Jason Janke VT-1,2,3,4 II X X O ' I

        " SAN ONOFRE NUCLEAR GENERATING STATION                                                                       . 

SUMMARY

REPORT

        -UNIT 2                                                                                                          14 OF 16 A
k. f 6 ISI PROCEDURES & TRAVELERS c

ISI Procedures  : m . L SO23-IN-1 . Inservice Inspection Program  : l SO123-XVII-1 Inservice Inspection Program Implementation SO123-XVII-1.1 Insenice Inspection Maintenance  ! u SO123-XVII-3.1 Inservice Inspection of Class 1 Components and Their - Supports  ; i SO123-3.1.1 Refueling Outage Interval Examination of the Reactor Coolant Pressure Boundary to Detect Leakage' -l l i SO23-XVII-3.2 Inservice Inspection of Class 2 Components and Their O Sngverte l i SO23-XVII-3.3 Inservice Inspection of Class 3 Componentrs and Their y Supports SO123-XVII-2 Inservice Inspection of Reactor Coolant Pump Flywheels - ISI Construction Work Orders (Travelers) . Inside Containment.. . . . . .. . . . .... ... . . . ... ... ... . . ... . . ........... ... ......... ....... .. . . 94 0825 04 Outside Contaimnent. . . . ..... ............................... .. ... ... . .. ....... . ... . . . .. . . . 941005 78 l f O

                                                                                      *1'   .h i     <

i SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2 15 OF 16 p 7- AUGMENTED EXAMINATIONS i Low Pressure Turbine Disc UT Examination , ISIID Repetetive Maintenance Order (Traveler)  ; S21301MK003 10000661200  ; S21301MK004 10000661200 ' t

                                                                                               ?

i 1 i f I i i l O l

j

                                                                                                         -l SAN ONOFRE NUCLEAR GENERATING STATION     

SUMMARY

REPORT

                                         ' UNIT 2                                        ' 16 OF 16 :
 . ; ~,

_ .k. 8.0 STEAM GENERATOR EXAMINATIONS < 1 1 l O  : i e b

                                                                                                           )

h r O l i

                                                                                                           ?

i o m gg7

   ,    h L)                                                    Southem Califomia Edison Company P. O. Box 128 SAN CLEMENTE, CALIFOFtNSA D2674 0128
          ._ ,=" L'=*1__.                                                                          2*::=,,

U. S. Nuclear Regulatory Commission Document Control Desk

 ,              Washington, D.C. 20555 Gentlemen:

Subject:

Docket No. 50-361 Special Report Inservice Inspection of Steam Generator Tubes San Onofre Nuclear Generating Station, Unit 2

References:

PWR Steam Generator Examination Guidelines, Revision 3, Electric Power Research Institute (EPRI) Report Number NP-6201, dated November 1992. Pursuant to Surveillance Requirement 4.4.4.5(b) of Appendix A, Technical' ~

   /,_'l       Specifications to facility Operating License NPF-10, this report. is being submitted to the Commission following the completion of an inservice
   \- /        inspection of steam generator tubes at San Onofre Nuclear Generating Station,                4 Unit 2.

i Eddy current inspection of the steam generator tubing was completed March 5,  ! 1995. A total of 18,054 tubes (100% of the tubes in service) in two steam generators were inspected full length and 45 tubes were removed from service ' by mechanical plugging. This inspection significantly exceeded the amount of tubing required to be inspected per Surveillance Requirements 4.4.4.0 through 4.4.4.2. The inspection programs for both steam generators were fully consistent with the referenced industry recommendations. The programs included inspection of - the full length of all tubes with the bobbin probe, and inspection of all I tubes with a motorized rotating pancake coil (MRPC) at the inlet top-cf- . tubesheet location. The programs also included inspection of seven percent of the tubing with an MRPC probe at the outlet top-of-tubesheet location. In Steam Generator E-088, 9073 tubes were inspected full length. Fourteen tubes were found with the MRPC probe to have circumferential indications at the inlet top-of-tubesheet location and were plugged. One tube was found with the MRPC probe to have both circumferential and axial indications at the inlet top-of-tubesheet, and was plugged. One tube was found with the MRPC probe to have a volumetric indication (i.e., no specific axial or circumferential aspect) at the inlet top-of-tubesheet, and was plugged. One tube was found o

 ,6      Document Control Desk                  '

a

    )

with the MRPC probe to have a distorted indication at the outlet top-of-tubesheet, and was plugged. MRPC probe testing of this indication revealed that it was a volumetric indication. One. tube was preventively-plugged due to tie-rod denting. One tube in E-088 was found to be defective, due to a 84% throughwall indication within the explosively expanded region within the tubesheet, and was plugged. An additional tube was found with a non-quantifiable bobbin probe indication within the explosively expanded region within the tubesheet, and was plugged. MRPC probe testing of both of these tubes within the tubesheet revealed that the indications are oriented axially. One tube in E-088 was found with a distorted support indication by bobbin probe at the seventh eggerate support on the inlet side of the tube, and was pl ugged. One other tube in E-088 had a non-quantifiable indication by bobbin probe at the sixth eggerate support on the inlet side of the tube, and was plugged. MRPC probe testing of the indications in these two tubes, revealed an axial orientation of each of these indications. In Steam Generator E-089, 8981 tubes were inspected full length. Twelve tubes were found with the MRPC probe to have circumferentia'l indications at the inlet top-of-tubesheet location and were plugged. Two tubes were found with the MRPC probe to have axial indications at the inlet top-of-tubesheet, and were plugged. Four tubes were found with the MRPC probe to have a volumetric n indication (i.e., no specific axial or circumferential aspect) at the inlet (v) top-of-tubesheet, and were plugged. Also, in E-089 one tube was preventively plugged due to degradation at a vertical strap support. Two tubes in E-089 were found to be defective, due to greater than 90% throughwall indications within the explosively expanded region within the tubesheet, and were plugged. MRPC probe testing of these two tubes within the tubesheet revealed that the indications' are oriented axially. One tube in E-089 was found with a distorted support indication by bobbin probe at the sixth eggerate support on the inlet side of the tube, and was plugged. One other tube in E-089 had a non-quantifiable indication by bobbin probe at the seventh eggerate support on the inlet side of the tube, and was plugged. MRPC probe testing of the indications in these two tubes, revealed an axial orientation of each of these indications. As required by Surveillance Requirement 4.4.4.5(b), complete results of the recently completed inservice inspection of steam generator tubing are provided in the enclosures. Enclosure 1 provides the steam generator internal location reference guide. The eddy current indication locations listed in the remaining enclosures are based upon this guide. Enclosure 2 provides a list of abbreviations used to describe the indications from MRPC probe testing in the remaining enclosures. Enclosures 3 and 5 provide a list of eddy current testing indications, including tube identification, indication depth for bobbin probe indications, indication description for MRPC probe indications, bV

7 x Document Control Desk

  • and the axial location of the indication in the tube. Enclosures 4 and 6 provide a list of tubes plugged after completion of _the inservice inspection.

If you require any additional information, please so advise. Sincerely, Enclosures (6): cc: L. J. Callan, Regional Administrator, NRC Region IV J. E. Dyer, Director, Division of Reactor Projects, NRC Region IV K. E. Perkins, Jr., Director, Walnut Creek Field Office, NRC Region IV '4 J. A. Sloan, NRC Senior Resident, San Onofre Units 1, 2 & 3 M. B. Fields, NRC Project Manager, San Onofre Units 2 and 3 Institute of Nuclear Power Operations (INPO)

      #^

(,-) Code Case Used: American Society.of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code, Section XI Code Case N-401-1. Diaitized Collection and Storace of Eddv Current Test Data. I l I i

  /        \

U I l

eg,g. ,;

                                        . <                  y                                  -
                                                                                                                                                                          ~--
  ,g                 ;g
                                                <r                  1                                                                                               -
          ,,'n                                                                                                                                                                     -
                                                                                                                                                                                                          '1
         ; n .+                                                                                                                                                                 ..s.

a  :'^t . Page21:,of 43 o

                               . . .y c

t.. x- .. Enclosure 1" nyN. ..

     'kj/                                                               CE MODEL'3410 TUBE SUPPORT DRAWING VH2-          VSM                  VC2:
         -1
          .^

VH1' VH3 ' 'VC3 VC1 4

                     .s.                                                               .
                                                                                                  . g_                3                           g D8H.                                                         

1 DBC 10H. y ==== 10C I 30.75*- j 09H 0' ' 09C' n, 30,75* 08H OSC 30.75* 07H 07C' 38*

                                                                        .06H                                                                                 OSC
                                                                                                 -o 36*

OSH OSC o 9 35 *

                                             .                             MH                                                                                MC 38-03H                                                                              03C l

l' 36' 02H * 02C

j. .6 l

l l l.

                                                                                               .35*

01H ' h 01C

                                                                                ~I M 8.2 5 t        "
                                                                                                                                                          ~

p TSH t o u f% J TSC 23.00* O.

                                                                                                                                                                                                        .1 TEH                     Y r                                   ,       ,                         ,   TEC ItJLET                                         OUTLET 1<

R lL

                                                                                                                                                                                            ........A

m. L Page 2 of 3 , , , s.

               '~ ~'

1 Enclosure 1 CLARIFICATION OF TUBING / SUPPORT INTERFACES AB0VE THE 7TH FULL EGGCRATE SUPPORT ROW (S) TUBING / SUPPORT INTERFACES 120-147 08H.09H.10H.DBH.VH1.VH1.VH3.VSM.VC3.VC2.VC1.DBC.10C.09C.08C 115-119 08H.09H DBH.VHl.VH2.VH3.VSM.VC3.VC2.VC1.DBC 09C.08C 84-114 08H.09H DBH VH2.VH3,VSM.VC3.VC2 DBC 09C.08C 83 08H DBH VH2.VH3.VSM.VC3.VC2 DBC 08C 51-82 08H DBH VH3.VSM.VC3. DBC 08C , Oc 49-50 08H DBH VSM DBC 08C

                    )

19-48 DBH VSM DBC 1-18 DBH DBC e 9 9

                  )

i i

E n cl o s u.re 1 Page 3'of 3 s pi  :

                                     ,,        e Al     ,.
                                                                      . a                        e,l'.           y                                                                           <,

i to-w' c ll: l: ~ I l i x> d sg; l [l!!! n M ik

                                                                                                                             !! +
                                                                                                                                   ; s                                                                                        a 5

t-, as-

                                              ;c c

3 c

e ~: :s m s 43 c
                                              ;.               :   i ill                               eqp, 7            q           j; <j;;                                        :S                             3

{.- 3 .,-  : l h NINe .!l,!! ? :0: .- _ E g z v: .! ;0; & 3 .it:::; z 80-n e

                                                                                   !!W h          :

g f m fT1. 65- ' _ g  !* E f i --

-~ ., b  :

i b W!ili!ili.u 3 8 F p [p: E- +#j: jf i g*  : : a w

                   =                                                                 '                                           ~
                                                                                                                                   ;    .l      !  .!    h p
lf:l: 5 N

[: el p i .,- x u  : o too- h.j:! f

                                                                                                                                                                               ~
                                                                                                                    !        ll!L                                    hl               -

A ny;; %p(!!0 \\ w ;i

                                                                                                                          !d j!! d!l#l
                                                                                                        ~

j>  ; i  !

m. ~ :y  :

m . m o g tao- l , I sas- [ [

                                 ~
                                           $                                                                                                           y                                                                     8 l                             h                                                                       .

m g

                                --         m                                                                                                                                                                                 x iso-                 <                                                                           6 iss-             E 170
      /"'                373, w

a $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $$ )

                                                                                                          <- ROWS -->

_ _ _ _ _ _ _ - _ \

ks l Enclosure 2 LIST OF ABBREVIATIONS USED TO DESCRIBE THE INDICATIONS FROM MRPC PRODE TESTING Abbreviation Exolanation of the Abbreviation SCI Single Circumferential Indication MCI Multiple Circumferential Indications

  • SAI - Single Axial Indication-MAI Multiple Axial Indications
           .SVI-                      Single Volumetric Indication (i.e.,~ no specific axial or circumferential aspect)

I O  ; i a { 9 h

                                                     *                                                                                                   [

ENCLOSURE (3) CUMULATIVE REPORT 02/95, ' SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2 TEAM GENERATOR  : 88 . PAGE: 1 OF 3 TAGE DATA SET  : CURRENT DATE: 04/03/95 CTION VARIABLES: Percent TIME: 12:21:20 *

  ~ '

i j EXAM EXTENT l l l CURRENT l r

          ; ROWiCOL              LEG PROGRAM l ACTUAL EXP              CAL - PROBE       LOCATION                   VOLTS l MIL lDEG         %    CH l   ;

1 I I I I 31 11 lC TEC-TEHjTEC-TEH l00016 580UL DBH+ 1.78 0.58l 0 <20lP 2l 48 16 lC TEC-TEH TEC-TEH 00015 580UL TEH+ 14.27 10.73 52, 84lP 1l l l H 'TEH-TSH TEH-TSH 00114' 600RC TEE + 15.23 l41.88 l 30lSAI) 4; I l 43 19! lC ' TEC-TEH TEC-TEH l00016; 580ULl02H+ 0.87 l 0.66 l 0ll<20 P 2; ' l 89 19L lC TEC-TEH TEC-TEN l00029 580ULlVC2+ 0.88 l 0.64 l 0; <20 P 2;l ' l lC TEC-TEH TEC-TtH [00029 580ULlDBC+ 1.56 l 1.15'- l 0; 28 P 2]  ! l 78 22 lC TEC-TEHlTEC-TEH l00029 580UL VC3- 0.90 0.67 l 0L 20 P 2l I l~ 86 ' 24; lC TEC-TEHlTEC-TEHl ,00029 ;5800L 06H+ 0.00 0.76 l 01 22 P 2l l 54 28; lC, TEC-TEHlTEC-TEHl 00016 ,580UL 05C+ 19.31 0.33 l150 <20 1 88 28l lC TEC-TEH[TEC-TEHl 00029 580UL 09H- 0.37 0.70 l 0 <20 P2 27 -33 lC TEC-TEH TEC-TEH ,l 00011l 580UL 04H+ 1.81 1.13 l164 <20l 1 i 92 36 C TEC-TEH TEC-TEH [00031)580UL VH2- 0.70 0.63 l 0 <20 P2 [ l C l TEC-TEH TEC-TEH. l00031l580UL1VC2+ 0.93 0.62 0 <20 P 2' , l 82l 38;' C lTEC-TEHlTEC-TEH l00032l580ULlVC3+ 0.92 , 0.94  ; 0l 24 P 2  ! l113 39 C lTEC-TEH TEC-TEH l00031l580UL DBH+ 1.90 l 0.53 l 0 <20lP 2] . l 39 45 j H TSH-TSH TSH-TSH l00016l600RC TSH+ 0.00 j 1.90l 33 SVIl lj 37 47; [C TEC-TEH TEC-TEH *l00022l580UL VSM+ 0.75 l 0.27l 0, <20lP 2l , 561 48; jH TSH-TSH TSH-TSH l00018l600RC.TSH- 0.17 { 7.10l 19 SCI l .4 , l 24 1 52 lH l 07H-07HL07H-07H jo0108l600RCl07H+ ,0.00 l 0.38l 33 SAI ( 4 lC [TEC-TEHlTEC-TEHL l00021l580ULjoSC+ 20.61 l 0.74l ,151 . <20 ' 1 Ou;53, J7) 61l lC TEC-TEHlTEC-TEHl l00022l580UL VSM+ 0.83 l 0.61: l 0 <20; P 2l l 3 21l 65l lC ; TEC-TEHlTEC-TEH) l00022l580UL 01H+ 1.07 l 0.55 l 0 <20lP 2l  : l 71] 65l lC .lTEC-TEHlTEC-TEH l00025l580UL 02H- 1.20 l, 0.50l l O! <20 P 2l l l123; 65l LC ]TEC-TEHjTEC-TEH l00061l580UL DBH+ 1.07 , 0.33l l 0; <20,P 2l

                                                                                                                 ,1 0.84l j . 88' 66l          .

C TEC-TEHLTEC-TEH l 000391580UL[ 02C- 1.22 l. O. 20; P 2l.  ;

       } 58 l 68l           ,1 C TEC-TEHLTEC-TEH                  ! 00026 ;580UL, TSH+    1.49                   ,l 0.94            i 142    28      1l  l l 46 70              lC TEC-TEHi TEC-TEH                       00024 580UL TSH+    1.92                         1.23  ;        149    21     1 l 71 73             lC lTEC-TEH TEC-TEH                       00023 580UL 02H+    0.72                         0.35  ,

O <20; P2 l 73' 73 . lC lTEC-TEHl TEC-TEHj  ; 00040l580UL VSM+ 0.88 0.37 l 0l<20lP 2l  ; l133 l 75 . l .C lTEC-TEH)TEC-TSHl ),00066l5BOULHDBH+ 1.78 0.59 i 0l<20lP 2l 00066';580ULlDBH+ 1.82 l 0.85l 24' P 2] 145l 75l lC lTEC-TEH TEC-TSHl l 0 , 50l 76l l C lTEC-TEH TEC-TEHl  ; 00023; 580ULl01H+ 0.97 l 0.35l l 0.<20 P 2l l146l 76l lC lTEC-TEH TEC-01Hl [00066l580ULlDBH+ 2.12 0.55l l 0 24lP 2 , l 77l 77l lH lTSH-TSH' TSH-TSHl l00030l600RClTSH- 0.09 1.44l l 25 SCI l 4  ! l 95 77 lH TSH-TSH; TSH-TSHl l00031l600RC TSH- 0.08 5.12l l 11 SCI 4L l l101 77; lC TEC-TEH]TEC-TEHj l00052l580UL DBH+ 1.91 0.72l l 0 <20 ,P f.  ! l119l 77l lC [TEC-TEH TEC-TEHl l00053l580UL VH2- 1.00 0.63l l 0 <20lP 2 t l146l 78l lC lTEC-TEH TEC-TEHl l00066l580UL DBC- 1.68 1.07] l 0 . 28lP 2 l l 69l 79l C lTEC-TEHlTEC-TEHl l00023j580ULl03H- 0.67 0.50 l 0l<20]P 2; l 77l 79l H lTSH-TSHlTSH-TSHl l00030l600RClTSH- 0.23 5.43 l 16l SCI l 4 l 0.48l 0 <20l,P 2 143l 79 ]C lTEC-TEHlTEC-TEHl l00132l580ULlDBC+ 1.38 l  !

      '144l 80              lC lTEC-TEHlTEC kTEH                  l00068l580ULl DBH+ 2.08                          1 0.24l          l   0 .<20) P 2;      6 l145           811    lC JTEC-TEH TEC-TEH                   l00069]S80UL VH1- 1.06                               0.31             0 <20 P 2l       l
 ,    l                  l  lC lTEC-TEH TEC-TEHL                  l00069l580ULlDBC- 1.61                               0.48    ,

0 .<20lP 2l [

      . 147;     Bli    lC        TEC-TEH TEC-TEH                 00068' 580UL DBC- 1.48                           0.34             O   <20 P2 CONAH NUCLEAR, INC.

l

CUMULATIVE REPORT 02/95, SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2 ' STEAM GENERATOR  : 88 PAGE: 2 OF 3 M *"TAGE DATA SET  : CURRENT DATE:

        ),ECTIONVARIABLES: Percent 04/03/95 (v                                                                                                           TIME:             12:21:20 i            EXAM Ex m r           l        l                                   CURRENT                        l
       ; ROW COL                  LEG PROGRAM l ACTUAL EXPl CAL l PROBE                  LOCATION     VOLTS     MIL' DEG '% 'CH l                 I I              I        I                                                                  l 55: ~83l             lC       TEC-TEHlTEC-TEH             00138 580SM DBH-      1.58        0.49 j
52) 84l 00140; 580SM lDBC-0:<20lP 2[

l C lTEC-TE lTEC-TEH 1,81 0.45l 0l<20lP 2l 84l 84 E TSH-TSHlTSH-TSH l00085,600RClTSH- 0.11 8.00 4 15l SCI 138l 86 C TEC-TEHjTEC-TEHj i00068 580ULjvH1- 0.83 0.60 0l<20 P2 l140 86 C TEC-TEH, TEC-TEH l00069 580UL,VH1- 0.90 1.00 0l 27, P 2ll l142l 86, C TEC-TEH TEC-TEH.' l00068j580UL DBH+ 1.88 , 0.30l 0 <20jP2' I l147 87' lC TEC-TEH lTEC-TEH] l00068l580UL DBC+ 1.77 ) 0.53 0 <20lP

  • j 84 88' lH 'TSH-TSHilTSH-TSHj l00037l600RC ITSH+ 0.02 l 5.26' 183 SCI l 4 l123 89l C lTEC-TEH TEC-TEH l00126l580UL. VH2+ 0.87 0.42[ O <20l P ~

l147, 89 C lTEC-TEH TEC-TEH l001261580ULJVC1+ 0.77 0.42) l 0 <20 P* l 72l 90j l C lTEC-TEHjTEC-TEHl  ; 00137 '580SM) VSM+ 1.07 0.56l l 0 <20 lP *

.      L137l 91L               l C lTEC-TEH TEC-TEHl              l 00128 580SM 10H-       0.96    l 0.26              l    0 <20j P 2.,         !

49 93, lC (TEC-TEH TEC-TEHl l00140 '580SM 'DBC- 1.94 l 0.63, 145 93; l 0l<20 lP 2 i lC LTEC-TEH TEC-TEH! l00128 580SMl VC1+ 0.83 jl 0.56 L l 0]<20 P2 50 94l Cl TEC-TEH. TEC-TEH l00102, 580ULLDBC- 1.94 0.42l l 0 '<20 P 2l L147 95l C TEC-TEH TEC-TEH l00127 580SM; VC1+ 0 28 P 2l 0.96 0.59l l

84) 96l lH TSH-TSH lTSH-TSH l00041 600RCl TSH- 0.22 l11.35l l 25 SCI : 4l 72] 98l lC TEC-TEH!TEC-TEH l l 00101 l 580UL) 02C+ 2.60 0.94l l151,<20L 1l 144l 98 l l C lTEC-TEHlTEC-TEHl l00127l580SMlDBC+ 1.63 1.34 l l 0 28'P 2l
    .' 79l 99 l                l C lTEC-TEHlTEC-TEHl             l00106l580UL 02H-       *1.41    l    0.71 l      0 <20       P 2l
       }6l102          I       l C )TEC-TEH TEC-TEHl             l00120l580UL. DBH+       0.89    l 0.24             l      0; <20     'P 2l vi8 L102                     lC        TEC-TEH TEC-TEHl        l 00121 l 580SM ,l DBH-  2.59    j 0.74'            l      0,<20;P 2l

[ l C TEC-TEHlTEC-TEHl l00121l580SM DBH+ 2.95 1.03l l 0J 24lP 2l 138;!102 C lTEC-TEH.TEC-TEHl l00127l580SM DBH-l 1.79 1.28l l 0; 28lP 2l 75l'103 HjlTSH-TSH; TSH-TSHl ,'19.01l l00106l600RClTSH- 0.05 l 5 SCI l 4l 72l104 lH i TSH-TSH TSH-TSHl l00045l600RClTSH+ 0.07 0.92l l 0 , SCI] 4] l l l H TSH-TSH TSH-TSHl l00045 600RC TSH+ 0.21 1.45[ 113 SAIL 4l l 31j105l C TEC-TEH;TEC-TEHl l00087,580UL DBH- 1.78 l 0.61l OQ<20lP 2l l 90 110 C ;TEC-TEHlTEC-TEHl l00105'580UL VH3+ 0.72 0.24l l 0 <20]P 2[ l 31 111 , H lTEH-TSHlTEH-TSHl l00109 '600RC, TSH- 14.16 29.03l ] 17 SAI:l 4l l 60L112; lH lTSH-TSHlTSH-TSHl l00104 600RC TSH- 0.16 3.53; l 29l SCI 4l l 79 l113 l: lC lTEC-TEHlTEC-TEHl l00105l580UL 03H+ 9.66 0.56, l152l<20 1l l 9l115; H l06H-06Hl06H-06Hl l00109l600RC I 06H+ 0.07 j 1.24l l 65lSAIl 4l l133l115 C lTEC-TEHlTEC-TEHl l00128l580SM 10H- 0.98 j 0.25l l 0l<26lP 2l l 29 l119 ll , H TSH-TSHlTSH-TSHl l00080l600RC.lTSH- 0.14 l 9.18l [ 26l SCI l 4l lH TSH-TSHjTSH-TSHl l 24l122l l00080j600RClTSH- 0.07 l15.41l 14l MCI l 4l l 51l123 il l C iTEC-TEHlTEC-TEHj l00097 580UL l DBC+ 0.06 l 0.32l 0. <20lP 2l l122l124ll lC! TEC-TEHlTEC-TEHl l00116 58 0SM . DBH+ 1.80 0.35l , O <20lP 2l l131l127 ) C TEC-TEHjTEC-TEHl lOO129j580SM 03C+ 0.75 0.37l l114 <20 P 1 l l 50!l128 , H ; ;TSH-TSHlTSH-TSHl l00088l600RC' TSH- 0.15 7.05l l 9 SCI 4 58! 132 H lTSH-TSHlTSH-TSHl l00103l600RC)TSH- 0.13 l16.51l l 11 SCI 4l < l 86 132 , C lTEC-TEHlTECaTEHl l00102l580ULjoSH- 0.21 l 0.70j l 0 (<20 P 2l ,

    ,1 45' 133       .

lC lTEC-TEHlTEC-TEHl l00094l580ULlO1H+ 0.95 l 0.57l l 0 <20lP 2[

    ] 73 133         ,

l C lTEC-TEHjTEC-TEH] l00102l580ULlVH3+ 0.93 l 0.37l l 0,<20lP 2l l 28 134 .l lC lTEC-TEHlTEC-TEHl l00082l5BOULlVSM+ 1.20 l 0.62l l Ol<20lP 2l 1 1 I l I i i l i l I I i l I I CONAM NUCLEAR, INC.

CDMULATIVE REPORT 02/95, SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2 STEAM GENERATOR  : 88 PAGE: 3 OF 3

    ~~
 ,-      s  AGE DATA SET          : CURRENT                                                             DATE:       04/03/95
        )'ECTIONVARIABLES:           Percent                                                            TIME:       12:21:20               ,

I l l HAM ETENT l , l l CURRENT l l ROW COL l LEG PROGRAM; ACTGALlEXP CAL lPROBEj LOCATION tr CH I VOLTS l MIL lDEGl l l l L H . I  !  ! , l 76 l134l lC lTEC-TEH TEC-TEH l 00101l 580'JL; VH3+ 0.71 l 0.35 0j<20 P 2; , 1105.135l lC lTEC-TEH TEC-TEH. J00115l580SMj08H- 0.09 l 0.64 0d<20 P 2l I l123]135 lC lTEC-TEH TEC-TEHL J00129l580SMiVH2+ 1.32 l 0.58i 0ll<20lP 2l l l 23 '137 lH lTSH-TSH TSH-TSHl  ; 00076 i600RCjTSH- 0.18 l 3.34 j 27 'SCIj 4l  ! 97 143l C lTEC-TEH lTEC-TEH 00112 580SM VH2- 0.78 0.45; O <20 P 2l 112 144l C lTEC-TEH TEC-TEH 90112 580SM. DBH+ 1.97 1.28: 0 27 P 2] 00112' 580SM[VH3-74[146l  ; C LTEC-TEH TEC-TEH 1.00 l 0.70l O' 23 P2 ' l l C TEC-TEH) TEC-TEH ;00112l 580SM 'VC3+ 0.74 l 0.58 0l 20 P2 83l155l ,C TEC-TEH TEC-TEH :00152l580UL 05H+ 0.72 l 0.21 0l<20 P2 l 1l157l lC lTSC-TSC'TSC-TSCj  ; 00076 l 600RC.lTSC- 0.01 l43.10 57lSVI 4l 67l159l C lTEC-TEH)TEC-TEHj l00111l580UL VH3- 1.00 l 0.27 0) <20 P2 i 75l161l C TEC-TEH TEC-TEHl l00111l580UL. VSM+ 0.81 l 0.29 0i <20 P2 67l165l ,lC TEC-TEH TEC-TEHj 00110l580SM VH3- i.87 l 1.21] 0; 28 (P 2 l l 111691 lC .ITEC-07C TEC-07CI 00010l580un 02C+ 3.75  ! 1.11l l159; <20l 11 l 1 1 I I L i I I _1 I l I I NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: l 97 i NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 104 NO TREND ANALYSIS REQUESTED

            . SELECTION CRITERIA:

V rcent: MAI, MCI,MVI,SAI, SCI,SVI, O to 100t REPORT OPTIONS: Only examination results matching criteria are included e ( CONAM NUCLEAR, INC. L)

                                                                                  ,   j .

7- - Page 1 of 2

 .I C'                                Enclosure 4 LIST OF TUBES PLUGGED San Onofre Unit 2 Steam Generator.E-088-l Row        Column                        Reason 48 16                 84% Indication at TEH + 14.3 i'

39 45 Preventive Maintenance 56 48 Preventive Maintenance i t 24 52- Preventive Maintenance 46 70 Preventive Maintenance ' 77 77 Preventive Maintenance , 95 77 Preventive Maintenance 77 79 Preventive, Maintenance 84 84 Preventive Maintenance 84 88 Preventive Maintenance  : 84 96 Preventive Maintenance 1 75 103 Preventive Maintenance , 72 104 Preventive Maintenance 31 111 Preventive Maintenance i 60 112 Preventive Maintenance l 9- 115 Preventive Maintenance 29 119 Preventive Maintenance  ! i

  • s i

V m

             +                                                                                                                                                 -

I l

        .o                                                                                                                                                        l l
                                                                                                                                           -Page 2 of 2.         :
     /"'T '
     \' /'                                                                                            Enclosure 4 i

I l LIST OF TUBES PLUGGED ' San Onofre Unit'2 Steam Generator E-088 , i Row' Column -Reason 24- 122 Preventive Maintenance  ! 50 128 Preventive Maintenance l 58' 132 Preventive Maintenance ~! I t

                       -23                                                                137                 Preventive Maintenance.

1 157. Preventive Maintenance t i i 1 r

                                                                                                                                                            . l 5

l P k i

 - -. -_       . . - . . - - . - _ _ ~ . - . . . - - - - - . . _ . . _ . . . - . . .                                    . . - - . - . - ..               . . -

ENCLOSURE (5) . CUMULATIVE REPORT l 02/95, SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2 7 g TEAM GENERATOR  : 89 PAGE: 1 OF 4 i ) TAGE DATA SET  : CURRENT DATE: 04/04/95 V 2LECTION VARIABLES: Percent TIME: 09:17:22 l l l EXAM EX m T l l l CURRENT, l l ROW COLj l LEG l PROGRAM ACTUALjEXPl CAL PROBE LOCATION l VOLTS MIL lDEG.l't . lCH l l l  ! l l l l t 1 l 4 11 1l C lTEC-TEH TEC-TEHl '00003l580UL !TSC+ 6.77 O.60 l160 <20l 1l

       -          22:        2                   C lTEC-TEH; TEC-TEHI                  000031580n!vSM- 0.71                        0.82           ;
                                                                                                                                                        'O      22 -P 2l, 48l        8              lC lTEC-TEH TEC-TEHl                    L 00013l580UL'DBH-        2.07           ;     0.67                  0 <20;P 2l 13l        s              lC lnC-TEH nC-TEHI                      i00002l580ut      02C+    6.78           l     0.80,             156 <20l          1l 64l 10                    l C lTEC-TEH TEC-TEHj                   l00013l580UL 03C-         0.94           j 0.75                      0    <20lP 2' 59,      11              l C lTEC-TEH TEC-TEH]                    f00013l580UL VH3-         0.92           l 0.69                      0 i

54; 12

                                                                                                                                                              <20lP : l l C lTEC-TEH ;TEC-TEHj                                                            l 0.56 l00016'580UL .VH3+       1.01                                       O     <20'   Pl       f 53l 13                   i C InC-TEH nC-ml                        l00016 580n; vH3+        0.35            l 0.62                     0 <20        P :l l 26l 14             (             C lnC-TEHlnC-TEHl                  l00004'580ULlVSM+         0.96           l 0.64                     0 <20        P     ;

l 71l 15 [ H lTEH-TSHlTEH-TSH l00102.600RClTEH+ 13.94 l 9.11 9,SAIl 4j l l H TEH-TSHlTEH-TSH. !00102 L600RC TEH+ 14.75 '43.92' 18 '. SAI l 4l C TEC-TER TEC-TEH 00035 580UL, TEH+ 14.83 37 98lP l l , 10.03 1l 7s 15l l C l TEC-TEH ) TEC-TEH ;' l 00036 l 580s; DBH+ 2.00 1 0.36l 0;<20lP 2l c 70: 16l C lTEC-TEHjTEC-TEH ' l00036l580ULl0BH+ 4.40  ; 0.81, .l158 ll <20 l 1l l  : C L TEC-TEH inC-TEH , l00036l580nivSn- 2.09 0.28 0  !<20lP 2 l 14l 18, C n C- m lTEC- m 1000061580ULlDBC- 1.71 ,. 0.14 0;<20lr 2 44 18,l C TEC-TEH TEC-TEH, l00017 !580UL VSM- 0.88 l 0.30 0l<20lP 2] 62 18L lC ln C- m nC-TEHL 100018 580s vH3+ 1.11 il 0.52 0 <20lP 2L l 53 19l lC lTEC-TEH; TEC-TEHi l00017 580UL VC3+ 0.80 0.27l 0 <2 0, P2 18 20l lC ,lTEC-TEH TEC-TEHj l00017L580UL. DBH+ 'O.90 0.30l 0 <20, P 2; H, 48 22l 1 C. TEC-TEH nC-m l l00019l580unlDBH+ 0.32 , 0.17l  ;! 0l<20 P 2l 54; 22l C ; TEC- m TEC-nHl l00020l580utlDBH- 1.26 l 0.411 1180l<20 P 2l l 58l' 221 'H ITSH-TSH TSH-TSHI O00031600RCITSH+ 0.04 l 6.25  ! 45lSvIl 4l l 73l 23l , C lTEC-TEH TEC-TEHl . 00036l580ULlVC3- 1.47 l 0.32 ; , 0l<20lP 2l lC lTEC-nH TEC-nHl 74l 26l j00036l580ULlDBC+ 0.30 l 0.43 l 0 <20lP 2l i 75l 27l ' H j o6H-06H 06H-06Hl l00102l600RCl06H- 0.65 l17.38 l 23, MAIl 4l 10j 28l C E C-nHlnC- m l l0000Sj580ULjDBC+ 1.26 l 0.24 ll 0 <20 P 2l 72l 281 , C n'C-m l TEC-m l 1000351580ULIDBC- 0.30 1 0.53 , 0; <20 P 21 l 18l 30l i C , TEC-TEH l nC-m l 00009l580ULlDBH+ 1.75 0.37l 0 <20; P 2[ l 84l 301 C TEC-minC-TEHI 00036l580ULl07H+ 27.25 , 1.45l 160l<20L 11 l sil 311 C l TEC-nH l TEC-TEH l l 00035 l 580nlVH2+, 0.89 l 0.36l 0]<20lP 1l l 47l 33l C lTEC-TEH.TFC-TEHl l00022l580ULlDBH+ 1.90 l 0.45: 0l 23) P 2l , l 44l 34 C lnC-TEH TEC-TEHl l00021 580ULlDBH+ 1.86 l 0.64 0 <20) P 2l l 841 34 C ;I TEC-TEH) TEC-TEH I l00035 580nlvH2+ l 0.66

                                     ,                                                                       0.67                                      0       22 P 21 l Gli 39                    lC n C- m lTEC-TEHI                        l 00021l 580nivC3 +          2.27      l 0.78L                     157 L<20 i il l 76         l 42j          lC ;TEC-TEHlTEC-TEHl                       l00037l580ULlDEC-            1.44     l 0.47                           01<20;P 2l 108       42L        l C ,TEC-TEH TEC-TEHl                      l00037l580ULlDBH-           2.50      l 0.39                 l         0 <20lP 2l l'

lC nC-TEH TEC- m ] l00037H580ULlDBH+ 2.22 l 0.45) l 0 <20lP 2l 122j 42 C TEC-TEH lTEC-TEH :00038 580ULjDBC- 2.65 1.05: 0,. 26lP 2j 121 ' 45 C, TEC-TEH; TEC-TEH '00039 580ULlVC2- 0.62 j 0.58l 0j<20 P 2l lC TEC-TEH TEC-TEHI 0003sll580utlvC1- 1.2s 0.311 0 <20 P2 75 47 jC TEC-TEH TEC*-TEHl 0004 2 )l 580UL l TEH+ 17.38 2.19l 44 92 P1 l l 1 H lTEH-TSM- TEH T3Hl l00101l600RClTEH+ 17.70 l15.44l . 9lSAI 4l l 43 L Sil C 1TEC-nH. REC- m l l00030l580ULIDBH- 1.36 l 0.22l l 0l<20 P 2l 63l 51] j C TEC- m lTEC-nHl l00030l580UL DBH- 1.12 l 0.15l l Ojc20]P 2l _l l l l l l l l l l l l P CONAH NUCLEAR, INC.

h CUMULATIVE REPORT 02/95, SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2

      ' TEAM GENERATOR.                  : 89                                                                       PAGE:                2-OF      4

[ IAGE DATA SET  : CURRENT DATE: 04/04/95 b ELECTION VARIABLES: Percent TIME: 09:17:22 I l l I EXM EXTENT l j CURRENT ll l ROW COLj LEG PROGRAM l ACTUAL lEXPj CAL PROBE LOCATION VOLTS MIL. DEG l t CH l

   .I                   i            ,                                                                                                                     I
         ;  51] 53l              H lTSH-TSH TSH-TSN        :         ; 00018 600RC TSH+     0.09               3.79l               21 SCI)         1       l
89) 53l H lTSH-TSH TSH-TSH l00017) 600RC TSH- 0.04 4.64 16LSCIl 4l 74 54 j C lTEC-TEH TEC-TEH' 00042[580DLl04H+ 24.31 O.68 .

149 20l 1l  ; 118, 54 C TEC-TEHl TEC-TEH , 00048l580ULjVH1- 0.75 0.66 0 <20lP 2l

  • 74, 56 C')TEC-TEH TEC-TEH .  ; 00042 580ULlDBH+ 1.12 0.47 O <20lP 2!

51;i 57 H l07H-07H. 07H-07H, f00101 600RCl07H+ 0.42 L24.17 24 MAI; P lj 50 l 58 C.lTEC-TEH TEC-TEHl l00030 580ULl02H- 0.93 l 0.57 0 <20 !P 2l 104 64 C lTEC-TEH TEC-TEHl I;00049 580ULlVH2- 0.75 l 0.24 0 <20lP 2] 49, 65 lC lTEC-TEH TEC-TEH'  ; 00033 580ULlVSM- 0.67 l 0.43; O <20' P 2l- - 131' 65, <20,P 2j lC lTEC-TEH TEC-TEH '00059l580ULlVH1+ 0.93 l 0.42; O l 133, 65 l lC lTEC-TEHlTEC-TEHj l00060 580UL DBC- 2.61 i 0.50l 0 <20lP 2 33 671 lC lTEC-TEH]TEC-TEHl- l00029 580UL VSM- 0.68 0.36l 0l<20lP 2 143; 67 lC lTEC-TEHlTEC-TEHl 00059l580UL DBH+ 1.85 0.62 0l<20lP 2] 49l'69 lH lTSH-TSHlTSH-TSH 00031l600RC TSH+ 0.07 5.89 , 131l SCI, 4j 137l 69l l C lTEC-TEHlTEC-TEH l00061l580UL VH1+ 0.53 .l 0.84l 0l<20; P 2L  ; l 143l 69l lC lTEC-TEHlTEC-TEH l l 00062 l 580UL ,l10H+ 1.09 ,l 0.94l 0 25 P 2j t 50; 70;  : l C lTEC-TEHlTEC-TEL! l 00032 l 5800L' 08H+ 0.80 0.25l 0 <20 P2 l:138 l 70; C lTEC-TEHlTEC-TEHj ;iOOO62l580UL DBH+ 0.58 0.58l 0 . <2 0 ;lP 2; i l 31 71) C lTEC-TEHlTEC-TEHl , 00028l580UL DBH- 1.87 0.46] l 0 <20lP 2l  ; C lTEC-TEHlTEC-TEH) . 00028j580UL DBC '1.48 , 0.44l 0 <20lP 2l ' 35; 71 lH lTSH-TSHjTSH-TSH 00035l600RClTSH+ 0.07 l 2.39l  ; 124 SVIl 4 51l 71;l lH HTSH-TSHjTSH-TSH l00035l600RClTSH- 0.07 ) 4.26l 28, SCI l 4 l141 71 ,lC TEC-TEH TEC-TEHl l00061 580UL;.DBH+ 28.00 0.88l L156, <20l 1) l116 72 ' C . TEC-TEH TEC-TEHl l00051 580UL; VC3 + 0.89 0.42l 0 <20lP 2]

  • l00037l600RC. TSH+' O.14 55 L 73 )! H lTSH-TSH TSH-TSHl 2.24 0lSVIl 4 l143l 73l l C lTEC-TEE TEC-TEHl l00061l580ULjDBC+ 1.94 0.31 Oj<20lP 2 l1451 73l lC lTEC-TEHl TEC-TEH. l00062l580UL]DBC- 1.75 1.05l 0 24lP 2 l l 50 74l lC . TEC-TEH TEC-TEH l00033l580ULlDBC- 1.84 0.47l 0 <20lP'2 l
      ] 90          74]          C . TEC-TEH TEC-TEHl            ll 00055 l 580UL l 02H-    1.15       j 0.67l                      0,    <20lP 2L         r l 118l 74l                 C ; TEC-TEHj7EC-TEHl                  00052l580ULl05H- 1.10          l 0.58]                   ,

O <20lP 2l 55 75l H TSH-TSH.TSH-TSHj 00037 l,600RC lTSH- 0.18

                                                                                                            ; 2.61;         l171l MCI l           4l       j 59      75ll     lCl       TEC-TEH TEC-TEN)          l 00032l580ULlTSH+         0.73               0.86;        l146l 24l             ll        l 44l 76ll        ]C         TEC-TEHjTEC-TEH i; 00032 l 580UL; DBC ' 1.21          .

0.33 0l<20lP 2 l l 50l 76)  ! C TEC-TEHlTEC-TEH'  ;'00033; 580UL DBC- 1.71 l 0.27 0l<20lP 2 ' l 54l 78 C jTEC-TEHlTSC-TEH] 1 00033i 580UL 04H+ 8.50 l 0.62) jl54]<20l 1l 1

l. C . TEC-TEHlTEC-TEHj l00055l 580ULlO4H+ 8.62 l 0.72 152 <20 l ll  ;

108) 78 l C TEC-TEHlTEC-TEHj l00053l 580ULl09H+ 14.64 l 1.18 158 <20 i 1  !

   .l 87l 79                ) C lTEC-TEH]TEC-TEHj                l 0004 6 l 580ULl 02H-     1.11      l 0.43ll                      0l <20'P 2;l           l 119 79           lC lTEC-TEHlTEC-TEH                  l00054l580UL ;VH3+ 1.09              l 0.56                        0     <20lP'2)l        j 145 ' 81                                                                                   l 0.46 lC lTEC-TEHlTEC-TEH                  l00061l580UL VH1+ 0.77                                    ,

O <20lP 2[ q 56, 82l C l TEC-TEH lTEC-TEH l l00032l580ULlVH3- 1.02 , 0.41] l 0 20.lP 2l j 60 84l H lTSH-TSH TSH"TSHj l 17 MAI' l00044l600RClTSH- 2.18 5.51 il 118 84; jC lTEC-TEH TEC.-TEHl l00054 580ULlVC2+ 0.53 0.44 l 0  ;<20i P 2l 105' 85' lC lTEC-TEH!TEC-TEH] l00053 580ULlVC2+ 0.97 0.43 i l 0 <20l P 2l 125 85! C TEC-TEHjTEC-TEH l00061 SBOUL 10H- 1.10 0,58 0 23; P 2l __ l i __ CONAH NUCLEAR, INC.

1 l CUMULATIVE REPORT 02/95, SOUTHERN CALIFORNIA EDISON, SAN ONOFRE, UNIT 2 STEAM GENERATOR  : 89 PAGE: 3 OF 4 7 6 TAGE DATA SET.  : CURRENT DATE: 04/04/95  !

                .uECTION VARIABLES: Percent                                                                                          TIME:               09:17:22        l l            l      EXAM EXTENT                     l                                     CURRENT ROW COL                                                                                                                                                 l LEG lPROGRAMl ACTUAL EXP.

CAL LPROBE I4 CATION  ; VOLTS l MIL DEG t CH l l l ! l146 ' 86, C TEC-TEH TEC-TEH )l 00062 ; 580UL DBH+ 1.90 1.13 i 56 0L 27lP 2l 88l lC TEC-TEHlTEC-TEH l00125 580UL;VSM+ 0.75 0.41 O! <20lP 2'

65) 91l lH i TSH-TSH 'TSH-TSH( l00046 '600RClTSH- 0.08 4.94; 9 SCI 'P 1 147 93l lC TEC-TEH; TEC-TEH l00121 580UL VC1+ 0.86 0.27 0 <20 P2 72 94l lC TEC-TEH TEC-TEH l00096)580UL VC3- 1.04 0.35 0 <20 P2 88l 94j lH TSH-TSH TSH-TSH; l60046j600RC TSH- 0.03 3.44 27 SCI, P1  !

491 99 lC ITEC-TEH TEC-TEHl l00093 580UL DBH- 1.80 0.49 0 <20LP 2;  ! 51L 99 lC TEC-TEH TEC-TEHl l00092 580UL VSM- 0.90 0.34 0, <20 P 2;; 103 99 TSH-TSH TSH-TSHl l lH l00048 600RC. TSH- 0.06 3.67 18 SCI 4l j146jl00l lC i TEC-TEHlTEC-TEHl l00121l580ULjDBH+ 1.55 1.43 l l 0l 23;P 2l l ) l C lTEC-TEH TEC-TEHl jo0121J580ULl01C+ 0.79 l 1.24j 0] 24lP 2l l 36; 102 l C lTEC-TEH TEC-TEHl l00085;l580ULlDBC- 1.89 l 0.53! 0 (<20lP 2]

 ,          l 69 l103                      lC ,lTEC-TEHlTEC-TEHl                        l00093ll580UL TSH+      3.79         l 1.23              Il159 <20l        1j    l l 34 110                      lH /TSH-TSHlTSH-TSHl                          l00076[600RC TSH-       0.70        l 7.28                 l 20;SAIl 4l l 99)'111l                    lH                  TSH-TSHlTSH-TSHl          l00052 600RC ;lTSH-     0.08        l 3.46[                  14l SCI l 4l l 20l112l                      lH                  TSH-TSHlTSH-TSHl          l00077,600RCjTSH+       0.00       l 8.79]                   24lSVIl 4l l 44l112l                      l C llTEC-TEHjTEC-TEHl                        l00092l580ULlVSM-       0.73            0.36l                 0l<20lP 21         l l 14l116l                      llC lTEC-TEHhTEC-TEHl                         l00084l580ULl07H-       0.03            0.65;                 0l<20lP 2 l 74l118, I

C lTEC-TEH TEC-TEHl l00105l580UL VH3+ 0.90 l 0.59 j 0 .<20 lP 2j l' l . C lTEC-TEH TEC-TEHl l00105l500UL VSM+ 0.90 0.62  ! 0 <20 !P 2] ll l 1C TEC-TEHlTEC-TEHl l00105 580UL VC3- 0.90 0.34; O <20 P 2l (O]f57l123) 95l123l

                                            ,H        ;     TSH-TSHlTSH-TSHl C lTEC-TEHlTEC-TEH l00098 600RClTSH-l00105, 580ULlVH2-0.08 0.58 3.21  l              52 SCI.       4[
                                                                                                                          ,     0.64  l           l   0.<20 P 2l         l l        l         l       .

C lTEC-TEHlTEC-TEH l 00105 l 580UL lVH2 + 0.74 l 0.70l 0 ' <2 0,l P 2 l ) l 60l124l lH lTSH-TSHjTSH-TSH l00098l600RC TSH- 0.16 l 4.00l [ 13 SCI l 4l I l122l126l lC lTEC-TEHlTEC-TEH l00114l580UL VH3+ 0.85 l 0.891 j 0 24lP 2l l 81l127l C lTEC-TEHlTEC-TEH l l00105l580ULlVSM- 0.92 l 0.9"l l O l 24lP 2 l l l l C lTEC-TEHlTEC-TEHl l00105l580ULlVC3- 0.74  ! 1.33l 0 29lP 2' l 74l128l C lTEC-TEHlTEC-TEHl lOO105l580ULlVSM . 1.08 l 1.47l 0 31lP 2L l 78l130l , C lTEC-TEHlTEC-TEHl l00105l580ULlVSM- 1.11 l 0.70l 0; <20lP 2

   '      l 74l132l              'l C lTEC-TEHlTEC-TEHj                               l00105l580ULlVC3- 0.83             l 0.27l               j      0;  <20lP 2l l 80l136l                 lC lTEC-TEHlTEC-TEHl                               l00096l580ULlVH3- 1.03             l 1.14l              l       01   27lP 2l l 68l140                  lC lTEC-TEHlTEC-TEHl                              l00096l5BOULlTSH+ 4.01             l 0.29l               l120l<20l 1l l 66l144,                lC lTEC-TEHlTEC-TEHl                               l00099l580ULlVSM- 0.39             l 0.4Gl               l      0l<20P 2l
           ' 21 '149 lH lTSH-TSHlTSH-TSHl                               l00084l600RClTSH+ 0.10             l 0.96l              l       0l SCI.      4l 42 150;             lC lTEC-TEHj7EC-TEHj                               l00087l580ULlDBH+ 1.99             l 0.45l             l        0l<20lP 2l.

51 153l lC lTEC-TEH]TEC-TEHl l00087l580ULlDBC+ 0.19 0.51 0l<20lP 2, 74l156l lC lTEC-TEHjTEC-TEHl l00103l580UL;VSM- 0.86 0.70 i 0l<20lP 2 l 49l157.' lC lTEC-TEHlTEC-TEHl l00123l580UL.VSM- 0.65 l 1.22ll 0l 29lP 2 l 74l160i lC lTEC-TEH TEC-TEHl l00102l580ULlVH3- 0.68 l 0.27] , 0l<20LP 2-l 24l164 lC lTEC-TEH TEC-TEHl l00077 580ULl01H+ 29.30 l 0.64 l139 27 il i I l l 1 1 I I I I I CONAH NUCLEAR, INC. [O

I

  .')'

4 e ! ;:l:-' -

                                                -           .                                       CCMUKATIVE REPCRT -                                                                   .s--
                                              - 02/95, SOUTHERN. CALIFOItNIA EDICOST, SAN ONOFRE,' UNIT 2 :                               -

I STEAM GENERA 1DR'  : 39

  • PAGE: . 4 OF. .-4 j W E DATA SET'  : CURRENT

,'7j- '

  • 4/04/95 l LECTION VARIABLES: Percent - TIME: = 09:17:22  !
                                                                                                                                                                                          ,3 4
                                                                                                                                                                                               +

NEMBER OF TURES SELECTED PROM' CURRENT OUTAGE: 118 i NtMBER OF DATA RECORDS SELECTED ' FROM . CURRENT. OUTAGE: ~ 131  ;;

              ~ NO TREND ANALYSIS REQUESTED                                                                      -
  ,           ' DATA SELECTION CRITERIA:-                                                                                                                                                 .
              = Percent: MAI, MCI,MVI,SAI, SCI,SVI, O to 100t'                                                                                                                            -['

nREPORT OPTIONS: '

              -Only examination results matching criteria are included                                                                                                                    .

I 1 i

          ~      .

I l l t t CONAM NUCLEAR, INC.

                   ---m   , = =   ,   r-  ,         - ~ , , - ~ , - ,       , - , , , , . - , - -      r, - - , -x, ,.  --%,- , 1- ,y,---   ,-.- . . . , - - - ,. n,,-,,,   , - , ,    -
  .,e                                                          Page 1 of 2    i
, 3%,y/                            Enclosure 6 LIST OF. TUBES PLUGGED San Onofre Unit 2 Steam Generator E-089                     .

Row Column Reason  ; , 71 15 -98% Indication at TEH + 14.8 . t 58 22 Preventive Maintenance 75 27 Preventive Maintenance - 75 47 92% Indication at TEH + 17.4 -i 51 53 Preventive Maintenance 89 53 Preventive Maintenance  ! 51 57 Preventive Maintenance- 1

        .s   49          69                 Preventive Maintenance            ;

35 71 Preventive Maintenance , 51 71 Preventive Maintenance 55 73 Preventive Maintenance 55 .75 Preventive Maintenance 60 84 Preventive Maintenance , 65 91 Preventive Maintenance i 88 94 Preventive Maintenance 103 99 Preventive Maintenance. r 34 110 Preventive Maintenance  ! 99- 111 Preventive Maintenance

                    ~

20 112 Preventive Maintenance 57 123 Preventive Maintenance w

i i

l
      -3                                                    Page 2 of 2       !
    ' ,' ')

Enclosure 6 LIST OF TUBES PLUGGED j San Onofre Unit 2 Steam Generator E-089 i l Row Column Reason , i 60 124 Preventive Maintenance 74 128 Preventive Maintenance , 21 149 Preventive Maintenance I 1 V O

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2

   ,r's .
 '.. 'qj                                                                    j ATTACHMENT 9                                           !

t LIST OF COMPLETED ISI NDE EXAMINATIONS AND  ; SYSTEM PRESSURE TESTS x 1 I i 5 O  : 4 0

UNTT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

,m Southern California Edison (w/

ISI ID NO. Area Description Cat Item Method Exam _Dt Report _num Result ZONE:1 02-001-054-01 REACTOR VESSEL FLANGE UGAMENT #1 BG1 B6.40 UT 02/22/95 295-08IUT-092 ACCEPT 02-001-054-02 REACTOR VESSEL FLANGE UGAMENT #2 BG1 B6.40 UT 02/22/95 295-08RTT-092 ACCEPT 02-001-054-03 REACTOR VESSEL FLANGE UGAMENT #3 BG1 B6.40 UT 02/22/95 295-08RTT-092 ACCEPT 02-001-054-04 REACTOR VESSEL FLANGE UGAMENT #4 BG1 B6.40 UT 02/22/95 295-08RTT092 ACCEPT 02-001-054-05 REACTOR VESSEL FLANGE UGAMENT #5 BG1 B6.40 UT 02/22/95 295-08IUT-092 ACCEPT ' 02-001-054-06 REACTOR VESSEL FLANGE UGAMENT #6 BG1 B6.40 UT 02/22/95 295-08RTT-092 ACCEPT 02-001-054-07 REACTOR VESSEL FLANGE LIGAMENT #7 BG1 B6.40 UT 02/22/95 295-081UT-092 ACCEPT 02-001 054-08 REACTOR VESSEL FLANGE UGAMENT #8 BG1 B6.40 UT 02/22/95 295-08IUT-092 ACCEPT i 02-001-054-09 REACTOR VESSEL FLANGE UGAMENT #9 BGl B6.40 UT 02/22/95 295-08KTT-092 ACCEPT l 02-001-054-10 REACTOR VESSEL FLANGE UGAMENT #10 BGl B6.40 UT 02/22/95 295-081UT-092 ACCEPT p 02 4 01-054-11 REACTOR VESSEL FLANGE UGAMENT #11 BG1 B6.40 UT 02/22/95 295-08IUT-092 ACCEPT 02-001-054-12 REACTOR VESSEL FLANGE UGAMENT #12 BG1 B6.40 UT 02/22/95 295-08IUT-092 ACCEPT 02-001-054-13 REACTOR VESSEL FLANGE UGAMENT #13 BG1 B6.40 UT 02/22/95 295-081UT-092 ACCEPT 02-001-054-14 REACTOR VESSEL FLANGE LIGAMENT #14 BG1 B6.40 UT 02/22/95 295-08KTT-092 ACCEPT 02-001-054-15 REACTOR VESSEL FLANGE UGAMENT 815 BGl B6.40 UT 02/22/95 295-08RTT092 ACCEPT 02-001-054-16 REACTOR VESSEL FLANGE UGAMENT #16 BGl B6.40 UT 02/22/95 295-08RTT-092 ACCEPT 02-001 054-17 REACTOR VESSEL FLANGE UGAMEPT #17 BG1 B6.40 UT 02/22/95 295-08RTT-092 ACCEPT 02-001-054-18 REACTOR VESSEL FLANGE UGAMENT #18 BG1 B6.40 UT 02/22/95 29508RTT-092 ACCEPT 02 101-056 01 REACTOR VESSEL CLOSURE STUD #1 BG1 B6.30 MT 03/02/95 295-081MT-010 ACCEPT 02-001-056-01 REACTOR VESSEL CLOSURE STUD #1 BG1 B6.30 UT 03/04/95 295-08RTT-173 ACCEPT 02 001-056-02 REACTOR VESSEL CLOSURE STUD #2 BG1 B6.30 UT 03/04/95 295-081UT-175 ACCEPT 02-001-056-02 REACTOR VESSEL CLOSURE STUD #2 BGl B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056 03 REACTOR VESSEL CLOSURE STUD #3 BG1 B6.30 UT 03/04/95 295-08RTT-174 ACCEPT 02-001 056 03 REACTOR VESSEL CLOSURE STUD #3 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001 4 56-04 REACTOR VESSEL CLOSURE STUD #4 BG1 B6.30 UT 03/04/95 295-081UT 172 ACCEPT 02-001-056-04 REACTOR VESSEL CLOSURE STUD #4 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-05 REACTOR VESSEL CLOSURE STUD #5 BG1 B6.30 UT 03/04/95 295-08RTT-171 ACCEPT 04/21/95 Page 1

I I UNIT 2 CYCLE 8 l ISICOMPLETED F.XAMINATIONS n Southem Califomia Edison , ( ) l L.J ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-001 056 05 REACTOR VESSEL CLOSURE STUD #5 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001 056-06 REACTOR VESSEL CLOSURE SWD #6 BGl B6.30 MT 03/02/95 295-08IMT-010 ACCEPT l 02-001-056 06 REACTOR VESSEL CIDSURE STUD #6 BG1 B6.30 UT 03/04/95 295-081UT-170 ACCEPT 02-001-056-07 REACTOR VESSEL CLOSURE SWD #7 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-07 REACTOR VESSEL CLOSURE STUD #7 BG1 B6.30 UT 03/04/95 295-08IUT-169 ACCEPT 02-001-056-08 REACTOR VESSEL CLOSURE STUD #8 BG1 B6.30 UT 03/04/95 295-08IUT-168 ACCEPT 02-001-056 08 REACTOR VESSEL CLOSURE STUD #8 BGl B6.30 MT 03/02/95 295-081MT-010 ACCEPT 02-001-056-09 REACTOR VESSEL CLOSURE SWD #9 BG1 B6.30 UT 03/04/95 295-081UT-167 ACCEPT 02-001-056-09 REACTOR VESSEL CLOSURE SIUD #9 BG1 B6.30 MT 03/02/95 295-081MT-010 ACCEPT , 02-001 4 56-10 REACTOR VESSEL CLOSURE STUD #10 BG1 B6.30 UT 03/04/95 295-081UT-166 ACCEPT 02-001-056-10 REACTOR VESSEL CLOSURE STUD #10 BG1 B6.30 MT 03/02/95 295-081MT-010 ACCEPT 02-001-056-11 REACTOR VESSEL CLOSURE STUD #11 BGl B6.30 MT 03/02/95 295 08IMT-010 ACCEPT (v/ 02-001 056-11 REACTOR VESSEL CLOSURE STUD #11 BG1 B6.30 UT 03/04/95 295-081UT-165 ACCEPT 4 l 02-001 056-12 REACTOR VESSEL CLOSURE STUD #12 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-12 REACTOR VESSEL CLOSUP2 STUD #12 BGl B6.30 UT 03/04/95 295-08IUT-164 ACCEPT 02-001-056-13 REACTOR VESSEL CLOSURE STUD #13 BG1 E6.30 UT 03/04/95 295-08IUT-163 ACCEPT l 02-001-056-13 REACTOR VESSEL CLOSURE SIUD #13 BG1 B6.30 MT 03/02/95 295-08IMT010 ACCEPT 02-001-056-14 REACTOR VESSEL CLOSURE STUD #14 BGl B6.30 UT 03/04/95 295-08IUT-162 ACCEPT 02-001-056-14 REACTOR VESSEL CLOSURE STUD #14 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-15 REACTOR VESSEL CLOSURE STUD #15 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-15 REACTOR VESSEL CLOSURE STUD #15 BG1 B6.30 UT 03/04/95 295-081UT-161 ACCEPT 02-001-056-16 REACTOR VESSEL CLOSURE STUD #16 BG1 B6.30 UT 03/04/95 295-08IUT-160 ACCEPT 02-001-056-16 REACTOR VESSEL CLOSURE STUD #16 BGl B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02-001-056-17 REACTOR VESSEL CLOSURE STUD #17 BG1 B6.30 MT 03/02/95 295-08IMT-010 ACCEPT 02 001-056-17 REACTOR VESSEL CLOSUPI STUD #17 BGl B6.30 UT 03/04/95 295-08IUT-159 ACCEPT 02-001-056-18 REACTOR VESSEL CLOSURE STUD #18 BG1 B6.30 MT 03/02/95 295-08IMT010 ACCEPT 02-001-056-18 REACTOR VESSEL CLOSURE STUD #18 BGl B6.30 UT 03/04/95 295-081UT-158 ACCEPT 02-001 057-01 REACTOR VESSEL CLOSURE NUT #1 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-02 REACTOR VESSEL CLOSURE NUT #2 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 04/21/95 Page 2

i l UNIT 2 CYCLE 8 ISICOMPLETED EXAMINATIONS

   -,     Southern Cahfarnia Edison e    N N

ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-001-057-03 REACTOR VESSEL CLOSURE NUT #3 BGl B6.10 MT 03/01/95 29548IMT-009 ACCEPT 02-001-057-04 REACTOR VESSEL CIDSURE NUT #4 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCIFT 02-001-057 05 REACTOR VESSEL CLOSURE NUT #5 BGl B6.10 MT 03/01/95 295-081MT-009 ACCEPT 02-001-057-06 REACTOR VESSEL CLOSURE NUT #6 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-07 REACTOR VESSEL CLOSURE NUT #7 BG1 B6.10 MT 03/01/95 295-08IMT009 ACCEPT 02-001-057-08 REACTOR VESSEL CLOSURE NUT #8 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT i 02-001-057-09 REACTOR VESSEL CLOSURE NUT #9 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-10 REACTOR VESSEL CLOSURE NUT #10 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-11 REACTOR VESSEL CLOSURE NUT #11 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-12 REACTOR VESSEL CLOSURE NUT #12 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-13 REACTOR VESSEL CIDSURE NUT #13 BGl B610 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-14 REACTOR VESSEL CLOSURE NUT #14 BGl B6.10 MT 03/01/95 295-08IMT009 ACCEPT j p 1 G) ( 02-001-057-15 REACTOR VESSEL CLOSURE NUT #15 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCEPT l

                                                                                                               \

02-001 4 57-16 REACTOR VESSEL CLOSURE NUT #16 BG1 B6.10 MT 03/01/95 295-08IMT-009 ACCEPT { 02-001-057-17 REACTOR VESSEL CLOSURE NUT #17 BGl B6.10 MT 03/01/95 295-08IMT-009 ACCEPT 02-001-057-18 REACTOR VESSEL CLOSURE NUT #18 BG1 B6.10 MT 03/01/95 29548IMT-009 ACCEPT j 02 001-058-01 REACTOR VESSEL CLOSURE WASHER #1 BGl B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT i 02-001-058-02 REACTOR VESSEL CLOSURE WASHER #2 BG1 B6.50 VT-1 03/01/95 295-08IVT 069 ACCEPT 02-001-058-03 REACTOR VESSEL CLOSURE WASHER #3 BG1 B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-058-04 REACTOR VESSEL CLOSURE WASHER #4 BGl B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-058-05 REACTOR VESSEL CLOSURE WASHER #5 BGl B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 02-001-058-06 REACTOR VESSEL CLOSURE WASHER #6 BG1 B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 02-001 4 58-07 REACTOR VESSEL CLOSURE WASHER #7 BGl B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-058-08 REACTOR VESSEL CLOSURE WASHER #8 BG1 B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 02-001-058-09 REACTOR VESSEL CLOSURE WASHER #9 BGl B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 02-001-058-10 REACTOR VESSEL CLOSURE WASHER 810 BG1 B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT

 ,/]    02-001-058-11 REACTOR VESSEL CLOSURE WASHER #11      BG1   B6.50  VT-1 03/01/95 295-081VT-069 ACCEPT V

02-001-058-12 REACTOR VESSEL CLOSURE WASHER #12 BGl B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT I 02-001-058-13 REACTOR VESSEL CLOSURE WASHER #13 BG1 B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 04/21/95 Page 3

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS 7, Southern California Edison < i  ;

    .)

ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02'001 058-14 REACTOR VESSEL CLOSURE WASHER #14 BGl B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-058-15 REACTOR VESSEL CLOSURE WASHER #15 BG1 B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02 001-058-16 REACTOR VESSEL CLOSURE WASIM #16 BG1 B6.50 VT-1 03/01/95 295-08IVT-069 ACCEPT 02-001-058-17 REACTOR VESSEL CLOSURE WASHER #17 BG1 B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-058-18 REACTOR VESSEL CLOSURE WASHER #18 BGl B6.50 VT-1 03/01/95 295-081VT-069 ACCEPT 02-001-080 AREAS ABOVE AND BELOW REACTOR CORE BNI B13.10 VT-3 03/08/95 295-08IVT-079 ACCEPT ZONE:2 02 002-001-S REACTOR CLOSURE HEAD FLANGE-TO-TORUS B-A Bl.40 MT 03/02/95 295-08IMT-013 ACCEPT WELD 02 002-001-V REACTOR CLOSURE HEAD FLANGE-TO-TORUS B-A Bl.40 UT 03/03/95 295-081UT-188 ACCEPT WELD 02-002-002 PEEL SEGMENT WELD @ l8 DEGREES B-A Bl.22 UT 03/03/95 295081UT-189 ACCEPT C 02-002-003 B-A Bl.22 d PEEL SEGMENT WELD @ 90 DEGREES 02-002-015-01 INSTRUMEhT NOZZLE #92 TO FTITING WELD B-J B9.11 UT PT 03/03/95 295-081UT-190 ACCEPT 03/02/95 295-08IPT-075 ACCEPT 02-002-015-01 INSTRUMENT NOZZLE #92 TO FTITING WELD B-J B9.11 UT 03/03/95 295-08IUT-182 ACCEPT 02-002-015-03 INSTRUMENT NOZZLE #94 TO FITTING WELD B-J B9.11 PI 03/02/95 295-08IPT-075 ACCEPT 02-002-015 03 INSTRUMENT NOZZLE #94 TO FTTIING WELD B-J B9.ll UT 03/03/95 295-08IUT-184 ACCEPT 02-002-015-N INSTRUMENT NOZZLE #95 TO FITTING WELD B-J B9.11 PT 03/02/95 295-081PT-076 ACCEPT 02 002-015-04 INSTRUMENT NOZZLE #95 TO FTITING WELD B-J B9.11 UT 03/03/95 295-08IUT-186 ACCEPT 02-002 015A-01 INSTRUMENT NOZZLE #92 -ICI FLANGE TO B-J B9.11 PT 03/02/95 29548IPT-075 ACCEPT GRAYLOCK FITTING 02-002-01 SA-01 INSTRUMENT NOZZLE #92 - ICI FLANGE TO B-J B9.11 UT 03/03/95 29548IUT-183 ACCEPT GRAYLOCK FITTING 02-002-015A-03 INSTRUMENT NOZZLE #94 -ICI FLANGE TO B-J B9.11 UT 03/03/95 295-08IUT-185 ACCEPT GRAYLOCK FTTI1NG 02-002-015A-03 INSTRUMENT NOZZLE #94 -ICI FLANGE TO B-J B9.11 PT 03/02/95 295-08IPT-075 ACCEPT GRAYLOCK FITIING 02-002-015A-04 INSTRUMENT NOZZLE #95 -ICI FLANGE TO B-J B9.11 UT 03/03/95 29548IUT-187 ACCEPT GRAYLOCK FITTING 02-002-015A-04 INSTRUMENT NOZZLE #95 -ICI FLANGE TO B-J B9.11 PT 03/02/95 295-08IPT-076 ACCEPT GRAYLOCK FITIING 04/21/95 Page 4

UNIT 2 CYCLE 8 ISICOMPLETED EXAMINATIONS

 ,_s   Southern Califania Edison

/ N,l) ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result ZONE : 12 02-012-001 SAFE END-TO-PUMP SUCTION NOZZLE WELD B-J B9.11 UT 03/09/95 295 08IUT-201 ACCEPT 02 012-00i SAFE END-TO-PUMP SUCTION NOZZLE WELD B-J B9.11 PT 02/27/95 295-08IPT-069 ACCEPT 02-012-002 SAFE END-TO-ELBOW WELD B-F B5.130 UT 02/20/95 295-081UT 142 ACCEPT 02-012 002 SAFE END-TO ELBOW WELD B-F B5.130 PT 03/01/95 295-08IPT-069 ACCEPT 02-012403 P ELBOW LONGITUDINAL WELD (TOP)-PUMP B-J B9.12 UT 02/28/95 295-081UT-143 ACCEPT END 02-012403 P ELBOW LONGITUDINAL WELD (TOP)-PUMP B-J B9.12 MT 02/27/95 295-08IMT006 ACCEPT END 02-012-003 SG ELBOWLONGTIUDINALWELD-S/G END B-J B9.12 MT 02/27/95 295-08IMT-006 ACCEPT 02-012-003 SG ELBOW LONGTIUDINAL WELD - S/G END B-J B9.12 UT 02/27/95 295-081UT 141 ACCEPT 02-012-004 P ELBOW LONGITUDNAL WELD (BOTTOM)- B-J B9.12 MT 02/27/95 295-08IMT006 ACCEPT ' O (./ 02-012-004 P ELBOW LONGITUDINAL WELD (BOTTOM)- B-J B9.12 UT 02/28/95 295-08IUT-144 ACCEPT PUMP END 02 012-004 SG ELBOW LONGTIUDINAL WELD - S/G END FJ B9.17 UT 02/27/95 295-08IUT-140 ACCEPT 02-012-004 SG ELBOW LONGrTUDNAL WELD - S/G END B-J B9.I2 MT 02/27/95 295-08IMT-006 ACCEPT l 02-012-005 ELBOW-TO PIPE WELD B-J B9.11 MT 02/27/95 295-08IMT-005 ACCEPT 02 412-005 ELBOW-TO PIPE WELD B-J B9.11 UT 02/27/95 295-08IUT-135 ACCEPT , I 02-012 006 P PIPE LONGITUDMAL WELD- PUMP END B-J B9.12 UT 02/27/95 295-08IUT-136 ACCEPT 02-012 006 P PIPE LONGITUDINAL WELD -PUMP END B-J B9.12 MT 02/27/95 295-08IMT005 ACCEPT 02-012-006 SG PIPE LONGTTUDINAL WELD - S/G END B-J B9.12 UT 02/27/95 295-08IUT-138 ACCEPT 02-012-006 SG PIPE LONGTTUDINAL WELD - S/G END B-J B9.12 MT 02/27/95 295-08IMT007 ACCEPT l 02-012-007 P PIPE LONGITUDINAL WELD- PUMP END B-J B9.12 UT 02/27/95 295 081UT 137 ACCEPT j 02-012-007 P PIPE LONGITUDNAL WELD- PUMP END B-J B9.12 MT 02/27/95 295 08IMT-005 ACCEPT 02-012-007 SG PIPE LONGITUDNAL WELD - S/G END B-J B9.12 UT 02/27/95 295-08IUT-139 ACCEPT l 02-012-007 SG PIPE LONGITUDNAL WELD - S/G END B-J B9.12 MT 02/27/95 295-08IMT-007 ACCEPT i 02 012-008 PIPE-TO-ELBOW WELD B-J B9.11 UT 02/2//95 295-08IUT-132 ACCEPT 02-012 008 PIPE-TO-ELBOW WELD B-J B9.11 MT 02/27/95 295-08IMT007 ACCEPT 02-012 009 P ELBOW LONGIIUDINAL WELD - PUMP END B-J B9.12 UT 02/27/95 295-08IUT-133 ACCEPT 04/21/95 Page 5

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS Southern Califomia Edison ISIID NO. Area Description Cat Item Method Exam Dt Report _num Result 02-012-009 P ELBOW LONGI 1VDINAL WELD-PUMP END B-J B9.12 MT 02/27/95 295-08IMT-007 ACCEPT 02412-009 SG ELBOW LONGITUDINAL WELD - S/G END B-J B9.12 UT 03/07/95 295481UT-195 ACCEPT 02-012-009 SG ELBOW LONGITUDINAL WELD - S/G END B-J B9.12 MT 03/07/95 295-08IMT-015 ACCEPT 02-012-010 P ELBOW LONGTIUDINAL WELD- PUMP END B-J B9.12 UT 02/27/95 295-081UT-134 ACCEPT 02-012-010 P ELBOW LONGTIUDINAL WELD -PUMP END B-J B9.12 MT 02/27/95 295-08IMT-007 ACCEPT 02-012-010 SG ELBOW LONGITUDINAL WELD - S/G END B-J B9.12 MT 03/07/95 295-08IMT-015 ACCEPT 02-012 010 SG ELBOW LONGTTUDINAL WELD - S/G END B-J B9.12 UT 03/07/95 295-08IUT-194 ACCEPT 02-012-011 ELBOW-TO-ELBOW WELD B-J B9.11 MT 03/07/95 295-08BfT-015 ACCEPT 02-012-011 ELBOW-TO-ELBOW WELD B-J B9.11 UT 03/07/95 295-081UT-193 ACCEPT 02-012-012 P ELBOW LONGITUDINAL WELD (OUTSIDE)- B-J B9.12 MT 03/07/95 295-08IMT-015 ACCEPT PUMP END 02-012-012 P ELBOW LONGITUDINAL WELD (OUTSIDE). B-J B9.12 UT 03/07/95 295-08IUT-1% ACCEPT PUMPEND n 02-012-012 P ELEOW LONGITUDINAL WELD (OUTSIDE)- B-J B9.12 UT 03/07/95 295-081UT-197 ACCEPT rUuP END 02-012-013 P ELBOW LONGITUDINAL WELD (INSIDE)- B-J B9.12 MT 03/07/95 295-08IMT-015 ACCEPT PUMP END ZONE : 13 02-013-001 PUMP-TO-SAFE END WELD B-J B9.11 PT 02/28/95 295-08IPT-068 ACCEPT 02-013-001 PUMP-TO-SAFE END WELD B-J B9.11 UT 03/09/95 295-08IUT-202 ACCEPT 02-013-002 SAFE END TO-PIPE WELD B-F B5.130 PT 02/28/95 295-08IPT-068 ACCEPT 02-013-002 SAFE END-TO-PIPE WELD B-F B5.130 UT 02/28/95 295-08IUT-145 ACCEPT 02-013-003 P PIPE LONGITUDINAL WELD- PUMP END B-J B9.12 MT 02/28/95 295-08IMT-008 ACCEPT 02-013-003 P PIPE LONGITUDINAL WELD-PUMP END B-J B9.12 UT 02/28/95 295-08IUT-147 ACCEPT 02-013-0M P PIPE LONGITUDINAL WELD - PUMP END B-J B9.12 MT 02/28/95 295-08IMT-008 ACCEPT 02 013 004 P PIPE LONGITUDINAL WELD - PUMP END B-J B9.12 UT 02/28/95 295-081UT-146 ACCEPT 02-013-011 SAFETY INJECTION NOZZLE-TO-SAFE END B-F B5.130 UT 03/06/95 295-08IUT-191 ACCEPT WELD / Q 02-013 4 11 SAFETY INJECTION NOZZLE-TO-SAFE END B-F B5.130 PT 03/06/95 295-08IPT-077 ACCEPT WELD 04/21/95 Page 6

UNIT 2 CYCLE 8 ISICOMPLETED EXAMINATIONS Southern California E6 son [- T ( ,/ ISI ID NO. Area Description Cat Item Method Etam_Dt Report _num Result 02-013-012 CHARGING NOZZLE-TO-SAFE END WELD 2" B-F B5.140 PT 02/28/95 295-08IPT-068 ACCEPT ZONE : 19 02 019-051 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/21/95 295-081PT 054 ACCEPT 02-019-051 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-081UT 099 ACCEPT 02-019-052 8" SCH 140 ELBOW-TO PIPE B-J B9.11 PT 02/21/95 295-08IPT 054 ACCEPT 02-019-052 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT-100 ACCEli 02-019 054 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/16/95 295-08IPT-051 ACCEPT 02-019-054 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/16/95 295-08IUT-091 ACCEPT , 02 019-055 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/16/95 295-08IUT-090 ACCEPT 02-019-055 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/16/95 295-08IPT-051 ACCEPT i 02-019-057 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/16/95 295-08IPT-051 ACCEPT (q ' 02-019-057 8" SCH 140 FIPE-TO-ELBOW B-J B9.11 UT 02/16/95 295-08IUT-089 ACCEPT 02 019-058 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/23/95 295-08IPT-062 ACCEPT 02-019-058 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT 101 ACCEPT 4 02-019-059 S" SCH 140 FIPE-TO-EIBOW B-J B9.11 PT 02/21/95 295-08IPT-053 ACCEPT 02-019-059 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-08IUT-102 ACCEPT 02-019-062 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/21/95 295-08IPT-053 ACCEPT 02-019-062 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-081UT-103 ACCEPT 02-019-063 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PI 02/21/95 295-08IFT 053 ACCEPT 02-019-063 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295 081UT-104 ACCEPT 02-019 064 8" SCH 140 PIPE-TO-REDUCER TEE B-J B9.11 UT 02/23/95 295-08IUT-106 ACCEPT 02-019 4 4 8" SCH 140 PIPE-TO-REDUCER TEE B-J B9.11 PT ' 02/21/95 295-08IPT-052 ACCEPT 02-019-065 8" SCH 140 REDUCER IEE-TO-PIPE B-J B9.11 PT 02/21/95 295-08IPT-052 ACCEPT 02-019-065 8" SCH 140 REDUCER TEE-TO-PIPE B-J B9.11 UT 02/23/95 295-OSIUT-105 ACCEPT 02-019-066 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/16/95 295-OSIUT-088 ACCEPT n 02-019 066 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/15/95 295-08IPT-047 ACCEPT 02-019-067 8" SCH 140 ELBOW-TO-PIPE B-J E9.11 PT 02/15/95 295-08IPT-047 ACCEPT 02-019-067 8" SCH 140 ELBOW TO-PIPE B-J B9.11 UT 02/16/95 295-081UT-087 ACCEPT 04/21/95 Page 7

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS Southern California Edison 7 t t ) v ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-019-069 8" SCH 140 PIPE-TO-VALVE B-J B9.11 FT 02/15/95 295-08IPT-047 ACCEPT 02-019 069 8" SCH 140 PIPE-TO-VALVE B-J B9.11 UT 02/16/95 295-081UT-086 ACCEPT 02-019-072 SIDE PLATE BOL71NG (2 PLACES)(DRAWING BG2 B7.70 VT-1 03/09/95 295-08IVT-078 ACCEPT NO. SO23-408-16 47) 02-019-110-F GUIDE F-A Fl.10A VT-3 03/01/95 295-081VT-071 ACCEPT 02-019-110-1 GUIDE W/ INTEGRALLY WELDED LUGS BK1 B10.10 PT 02/23/95 295-08IPT-063 ACCEPT 02-019-111-F AXIAL STOP F-A F1.10A VT-3 03/01/95 295-081VT-070 ACCEPT ZONT : 20 02-020-047 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/22/95 295-08IPT-057 ACCEPT 02-020-047 B" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT-107 ACCEPT 02-020-048 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/23/95 295-08IPT-061 ACCEPT 02 020-048 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-08IUT 108 ACCEPT n k 02-020-049 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/23/95 295-08]PT 061 ACCEPT 02-020-049 8" SCH I40 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT-109 ACCEPT 02-020-050 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/23/95 295-08IPT-059 ACCEPT l 02-020-050 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-08IUT-110 ACCEPT 02 420-051 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT-111 ACCEPT 02-020-051 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/23/95 295-08IPT-059 ACCEPT 02-020-052 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-08IUT-112 ACCEPT 02-020-052 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 PT 02/23/95 295-08IPT-064 ACCEPT 02-020-053 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UI 02/23/95 295-081UT-113 ACCEPT I 02-020 053 8' SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/23/95 295-08IPT-064 ACCEPT 02-020 054 8' SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-08IUT-114 ACCEPT 02-020 054 8" SCH 140 PIPE-TO-ELBOW B-J E9.11 PT 02/23/95 295-08IPT-060 ACCEPT 02-020-055 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 PT 02/23/95 295-08IPT-060 ACCEPT l 02-020-055 8" SCH 140 ELBOW-TO-PIPE B-J B9.11 UT 02/23/95 295-08IUT-115 ACCEPT f 02-020-056 8" SCH 140 PIPE-TO-ELBOW B-J G B9.11 PT 02/23/95 295-08IPT-060 ACCEPT 02-020-056 8" SCH 140 PIPE-TO-ELBOW B-J B9.11 UT 02/23/95 295-081UT-116 ACCEPT 04/21/95 Page 8

1

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS Southem Califomia Edison
j'_N, l O ISIID NO. Area Description Cat Item Method Exam ,Dt Report num Result l

1 02-020 063 8" SCH 140 PIPE-TO-VALVE B-J E9.11 PT 02/22/95 295-08IPT-055 ACCEPT ; 02-020-063 8" SCH 140 PIPE-TO-VALVE B-J B9.11 UT 02/23/95 295-081UT-117 ACCEPT ! l 02-020 084-I OUIDE & Y-STOP W/ INTEGRALLY WELDED BK1 B10.10 PT 02/23/95 295-08IPT-065 ACCEPT LUGS 1 l ZONE : 21 j 02-021 013 18" SCH 160 PIPE-TO-ELBOW B-J B9.ll UT 02/27/95 295-08IUT-127 ACCEPT 02-021-013 18" SCH 160 PIPE-TO-ELBOW B-J B9.11 PT 02/27/95 295-08IPT-066 ACCEPT 02-021-014 18" SCH 160 ELBOW-TO-PIPE B-J B9.ll PT 02/27/95 295-08IPT-067 ACCEPT 02-021-014 18" SCH I60 ELBOW-TO-PIPE B-J B9.11 UT 02/27/95 295-08IUT-128 ACCEPT 02-021-014A 18" SCH 160 PIPE-TO-ELBOW B-J B9.11 PT 02/27/95 29508IPT-067 ACCEPT l 02 021-014A 18" SCH 160 PIPE-TO-ELBOW B-J B9.11 UT 02/27/95 295-081UT-129 ACCEPT l 02-021-015 18" SCH 160 ELBOW-TO-PIPE B-J B9.11 UT 02/27/95 295-081UT-130 ACCEPT 02 421-015 18" SCH 160 ELBOW-TO-PIPE B-J B9.11 PT 02/27/95 295-08IPT-067 ACCEPT 02-021-016 18" SCH 160 PIPE-TO-ELBOW B-J B9.ll UT 02/27/95 295-08IUT-131 ACCEPT 02-021-016 18" SCH 160 PIPE-TO-ELBOW B-J B9.ll PT 02/27/95 29508IPT 067 ACCEPT l l l ZONE : 23 02-023-028-1 AXIAL STOP & Y-STOP W/NIEGRALLY BK1 B10.10 PT 03/01/95 29548IPT 072 ACCEPT l WELDED LUGS l l 02-023-280 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 UT 03/01/95 295-08IUT-157 ACCEPT l 02 023-280 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 PT 03/01/95 295-08IPT-074 ACCEPT 02-023-290 4" SCH 120 PIPE-TO ELBOW B-J B9.11 PT 03/01/95 295-08IPT-071 ACCEPT l 02-023-290 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 UT 03/01/95 29508IUT-156 ACCEPT 02-023-300 4" SCH 120 ELBOW-TO-PIPE B.J B9.11 PT 03/01/95 295-08IPT-071 ACCEPT 02-023-300 4* SCH 120 ELBOW-TO-PIPE B-J B9.11 UT 03/01/95 295-08IUT-155 ACCEPT 02 023-310 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 UT 03/01/95 295-081UT-154 ACCEPT 02-023-310 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 PT 03/01/95 295-08IPT-071 ACCEPT f} 02 023-320 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 UT 03/01/95 295 081UT-153 ACCEPT 02-023-320 4* SCH 120 ELBOW-To-PIPE B-J B9.11 PT 03/01/95 295-08IPT-071 ACCEPT 1 1 04/21/95 Page 9

UNIT 2 CYCLE 8 , ISI COMPLETED EXAMINATIONS l Southern Califamia Edison f i A) ISIID NO. Area Description Cat Item Metbod Exam _Dt Report num Result 02-023-350 4" SCH 120 PIPE-TO-TEE B-J B9.ll PT 03/01/95 295-08IPT-073 ACCEPT 02 023-350 4" SCH 120 PIPE-TO TEE B-J B9.11 UT 03/01/95 295-081UT-152 ACCEPT 02-023-370 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 UT 03/01/95 295-081UT-148 ACCEPT 02-023-370 4" SCH 120 PIPE TO-ELBOW B-J B9.11 PT 03/01/95 295-08IPT 070 ACCEPT 02-023 380 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 UT 03/01/95 295081UT-149 ACCEPT 02-023-380 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 PT 03/01/95 295-08IPT-070 ACCEPT 02-023-390 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 UT 03/01/95 295-08IUI-150 ACCEPT 02-023-390 4" SCH 120 PIPE-TO-ELBOW B-J B9.11 PT 03/01/95 295-08IPT-070 ACCEPT 02-023-400 4" SCH 120 ELBOW-TO-PIPE B-J B9.11 UT 03/01/95 295-08IUT-151 ACCEPT 02-023-400 4" SCH 120 ELBOW-TO-PIPE B-J B9.ll PT 03/01/95 295-08IPT-070 ACCEPT i ZONE : 25 (] 02-025-001 6" SCH 160 NOZZLE-TO-ELBOW B-J B9.11 UT 02/24/95 29548IUT-120 ACCEPT 02-025-001 6" SCH 160 NOZZLE-TO-ELBOW B-J B9.11 PT 02/24/95 295-08IPT-058 ACCEPT 02-025-016 VALVE BONNET BOLTING (SIUDS & NUTS) BG2 B7.70 VT-1 02/24/95 295-081VT-068 ACCEPT 02 025-017 VALVE CAP BOLTING (STUDS & NUTS) BG2 B7.70 VT-1 02/24/95 295-081VT-067 ACCEPT ZONT : 35 02-035-112 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT NO. S023-922-231-6) 02 435-113 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT066 dCCEPT NO. S023-922-231-6) 02-035-114 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT066 ACCEPT NO S023-922-231-6) 02-035-115 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 J2/17/95 295-081VT-066 ACCEPT NO. S023-922-231-6) 02-035-116 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT066 ACCEPT NO. S023-922-231-6) 02-035-117 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT NO. S024922-231-6) r i V 02-035-118 SEAL HOUSING-TO-FIANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT NO. S023-922-231-6) 04/21/95 Page 10

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

 , _    Southem Califamia Edison
  ~

ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02 4 35-119 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT NO. S023-922-2316) 02-035-120 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT NO. S023-922-2316) 02-035 121 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT1 02/17/95 295-081VT-066 ACCEPT NO. S023 922-231-6) 02-035-122 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-066 ACCEPT NO. S023 922-231-6) 02-035-123 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VI-l 02/17/95 295-081VT-066 ACCEPT NO. S023-922-231-6) 02-035-124 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 29548IVT-066 ACCEPT NO. S023-922-231-6) 02-035-125 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-066 ACCEPT ) NO. S023-922-2316) 02-035-126 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-066 ACCEPT CN NO. S023-922-231-6) 02-035-127 SEAL HOUSING-TO-FLANGE CAISCREW (DWG. BG2 B7.60 VT-1 02/17/95 295 081VT-066 ACCEPT NO. S023-922-2314) l ZONE : 36 i 02-036-112 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT NO. S023-922-231-6) 02 4 36-113 SEAL HOUSING-TO FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT065 ACCEPT l No. S023-922-231-6) 02-036-114 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 29548IVT-065 ACCEPT NO. S023-922-2314) 02-036-115 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-065 ACCEPT NO. S023-922-231-6) 02-036-116 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-065 ACCEPT NO. S023-922-231-6) 02-036-117 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT NO. S023-922-231-6) 02-036-118 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-065 ACCEPT /3 NO. S023-922-231-6) \ ) 02 036-119 B7.60 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 VT-1 02/17/95 295-081VT-065 ACCEPT NO. S023-922-231-6) 04/21/95 Page 11

UNIT 2 LTCIE 8 ISI COMPLETED EXAMINATIONS Southern Califomia Edison i \ LJ ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-036-120 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295 081VT-065 ACCEPT NO. S023-922-231-6) 02-036-121 SEAL HOUSING-TO FLANGE CAPSCREW (DWG. 3G2 B7.60 VT-1 02/17/95 295-081VT-065 ACCEPT NO. S023-922-231-6) 02-036-122 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT No. S023-922-231-6) 02-036-123 SEAL HOUSING-TO-1LANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT No. S023-922-231-6) 02-036-124 SEAL HOUSING-TO-FLANGE CAPSCREW(DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT NO. S023-922-131-6) 02-036-125 SEAL HOUSING-TO-FLANGE C. " SCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-08IVT-065 ACCEPT NO. S023-922-231-6) 02-036-126 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT 065 ACCEPT NO. S023-922-231-6) 02-036-127 SEAL HOUSING-TO-FLANGE CAPSCREW (DWG. BG2 B7.60 VT-1 02/17/95 295-081VT-065 ACCEPT [] NO. S023-922-231-6) () ZONE : 42 02-042-043 FEEDWATER NOZZLE-TO-EXTENSION WELD CF2 C5.51 UT 03/25/95 295-081UT-211 ACCEPT 02-042-043 FEEDWATER NOZZLE-TO-EXTENSION WELD CF2 C5.51 MT 02/16/95 295-08IMT-001 ACCEPT 02-042-043 FEEDWATER NOZZLE-TO-EXTENSION WELD CF2 C5.51 UT 02/16/95 295 081UT-098 ACCEPT ZONE : 43 I l 02-043 043 FEEDWATER NOZZLE-TO-EXTENSION WELD CF2 C5.51 MT 02/21/95 295 08DiT-002 ACCEPT 02-043-043 FEEDWATER NOZZ.LE-TO-EXTENSION WELD CF2 C5.51 UT 03/25/95 295-081UT-212 ACCEPT 02-043-043 FEEDWATER NOZZLE-TO-EXTENSION WELD CF2 C5.51 UT 02/21/95 29%081UT 097 ACCEPT l ZONE : 44 02-044402 18" SCH 80 EXTENSION-TO-ELBOW CF2 C5.51 UT 03/25/95 295-081UT-207 ACCEPT  ; l 02-044-002 18' SCH 30 EXTENSION-TO-ELBOW CF2 C5 51 MT 03/18/95 29508IMT-018 ACCEPT i 02-044 003 18" SCH 80 ELBOW-TO-PIPE CF2 C5.51 MT /,,1 03/15/95 295-08IMT-016 ACCEPT (,,/ 02 044-003 18" SCH 80 ELBOW-TO-PIPE CF2 C5.51 UT 03/25/95 295-08IUT-208 ACCEPT l 02 444-004 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 MT 03/16/95 295-08IMT-017 ACCEPT 04/21/95 Page 12

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

           ,_ s     Southan Califamia Edison

( \ () ISIID NO. Area Description Cat Item Method Esam_Dt Report _num Result 02 044-004 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 UT 03/25/95 295-081UT-209 ACCEPT 02-044-006 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 MT 03/21/95 295-08IMT-019 ACCEPT 02-044-006 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 UT 03/24/95 295-08IUT-210 ACCEPT 02-044-006A 18" SCH 100 PIPE-TO-SWEEP-O-LET CF2 C5.81 MT 03/07/95 295-08IMT-014 ACCEPT ZONE : 45 02-045-002 18" SCH 80 EXTENSION-TO-ELBOW CF2 C5.51 MT 03/23/95 295-081MT-022 ACCEPT 02-045-002 18" SCH 80 EXTENSION-TC-ELBOW CF2 C5.51 UT 03/25/95 295-08IUT-203 ACCEPT 02-045 003 18" SCH 80 ELBOW-TO SCH I)0 PIPE CF2 C5.51 UT 03/25/95 295-08IUT-204 ACCEPT 02-045-003 18" SCH 80 ELBOW-TO-SCH 100 PIPE CF2 C5.51 MT 03/16/95 295-08IMT020 ACCEPT 07-045 004 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 MT 03/16/95 295-08IMT-023 ACCEPT 02 045-004 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 UT 03/25/95 295-081UT-205 ACCEPT q 02 045-006 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 UT 03/24/95 295-081UT-206 ACCEPT 02-045-006 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 MT 03/22/95 295-08IMT021 ACCEPT 02-045-007 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 MT 03/03/95 295-08IMT-011 ACCEPT 02 045-007 18" SCH 100 PIPE-TO-ELBOW CF2 C5.51 UT 03/06/95 295-08IUT-177 ACCEPT 02-045-009 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 UT 03/06/95 295-08IUT-176 ACCEPT 02-045-009 18" SCH 100 ELBOW-TO-PIPE CF2 C5.51 MT 03/03/95 295-08IMT-011 ACCEPT 02-045-010 18* SCH 100 PIPE-TO-REDUCER CF2 C5.51 MT 03/06/95 295-08IMT-012 ACCEPT 02-045-010 18" SCH 100 PIPE-TO-REDUCER CF2 C5.51 UT 03/06/95 295-08IUT 178 ACCEPT 02-045-011 20" SCH 100 REDUCER-TO-PIPE CF2 C5.51 MT 03/06/95 295-081MT-012 ACCEPT 02-045-011 20" SCH 100 REDUCER-TO-PIPE CF2 C5.51 UT 03/06/95 295-081UT-181 ACCEPT 02-045-012 20" SCH 100 PIPE-TO-VALVE CF2 C5.51 MT 03/06/95 295-08IMT-012 ACCEPT 02 045-012 20" SCH 100 PIPE-TO VALVE CF2 C5.51 UT 03/06/95 295-08PJT-180 ACCEPT 02-045-015 20" SCH 100 VALVE-TO-PIPE CF2 C5.51 MT 03/06/95 295-08IMT-012 ACCEPT 02-045-015 20" SCH 100 VALVE-TO-PIPE CF2 C5.51 UT 03/06/95 295-081UT-179 ACCEPT l V)

       <          ZONE : 50 02-050-027A-DS40" ELBOW LONGTIUDINAL WELD - OUIER         CF2   C5.52                 UT         02/24/95 295-081UT-123 ACCEPT RADIUS 04/21/95                                                                                                            Page    13

UNTT 2 CYCLE 8 ISI COMFLETED EXAMINATIONS Southern California Edison 7 ISIID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-050-027A-DS40" ELBOW LONGITUDINAL WELD - OUTER CF2 C5.52 MT 02/24/95 295-08IMT-003 ACCEPT RADIUS 02-050 027B-DS40" ELBOW LONGITUDINAL WELD - INNER CF2 C5.52 UT 02/24/95 295-08RIT-124 ACCEPT RADIUS 02-050 027B-DS 40" ELBOW LONGTIUDINAL WELD - INNER CF2 C5.52 MT 02/24/95 295-081MT-003 ACCEPT RADIUS 02-050 028 40" ELBOW-TO-PIPE CF2 C5.51 UT 02/24/95 295-08IUT-126 ACCEPT 02-050-028 40* ELBOW-TO-PIPE CF2 C5.51 MT 02/24/95 295-08IMT-003 ACCEPT 02-050-028A-DS40" PIPE LONGTTUDINAL WELD CF2 C5.52 UT 02/24/95 295-08IUT-122 ACCEPT 02-050-028A-DS40" PIPE LONGIIUDINAL WELD CF2 C5.52 MT 02/24/95 295-08IMT-004 ACCEPT 02450-028A-US40* PIPE LONGIlVDINAL WELD CF2 C5.52 MT 02/24/95 29548IMT-003 ACCEPT 02-050-028A-US40' PIPE LONGrTUDINAL WELD CF2 C5.52 UT 02/24/95 295-08IUT-121 ACCEPT 02450430 40" PIPE-TO-PENETRATION WELD CF2 C5.51 UT 02/24/95 295-08IUT-125 ACCEPT I l fG. 02-050-030 40" PIPE-TO-PENEIRA110N WELD CF2 C5.51 MT 02/24/95 295-08IMT-004 ACCEPT 02-050440-F SNUBBER F-A F1.20C VT-3 03/07/95 295 08IVT-074 ACCEPT ZONE : 61 02-061-170A-LP 14" SCH 40 SR ELBOW BODY WELD - OUTSIDE CFI C5.12 PT 02/02/95 295-08IPT-026 . ACCEPT RADIUS 02-061-170B-LP.14' SCH 40 SR ELBOW BODY WELD -INSIDE CFI C5.12 PT 02/02/95 295-08IPT-026 ACCEPT RADIUS 02-061-171 14" SCH 40 ELBOW-TO-PIPE CF1 C5.11 PT 02/02/95 295-08IPT-026 ACCEPT 02 061-171 A-CB14" SCH 40 PIPE LONGTTUDINAL WELD CFI C5.12 PT 02/02/95 295-08IFT-026 ACCEPT 02-061-196-F SNUBBER F-A Fl.20C VT-3 01/18/95 295-08IVT-034 ACCEPT 02 061-217-F GUIDE & Y-STOP F-A Fl.20B VT-3 01/18/95 295-08IVT-035 ACCEPT 02-061-217-I GUIDE & Y-STOP W/ INTEGRALLY WELDED C-C C3.20 PT 01/18/95 295-08IPT-002 ACCEPT LUGS ZONE : 65 02-065-ll10-F VARIABLE SPRING F-A F1.20C VT-3 01/23/95 295-08IVT-042 ACCEPT V 02-065-ll20-F AXIAL STOP F-A F1.20A VT-3 02/01/95 295-08IVT-056 ACCEPT 02-065-1120-1 AXIAL STOP W/ INTEGRALLY WELDED LUGS C-C C3.20 PT 02/01/95 295-08IPT-037 ACCEPT 04/21/95 Page 14

l UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

       ,_     Southern California E& son
   !       )                                                                                                                                                                                                                                                                               i
          /                                                                                                                                                                                                                                                                                '

K.__ ISIID NO. Area Descripti?n Cat Item Method Exam Dt Report _num Result 02-065-1140-F GUIDE & Y-STOP F-A Fl.20B VT-3 02/01/95 295-08IVT058 ACCEPT j 02-065-1140-I GUIDE & Y-STOP W/ INTEGRALLY WELDED C-C C3.20 PT 02/01/95 295-08IPT 036 ACCEPT I f l WRAPPER PLATE ZONE : 66 1 l 02-066-132 FLANGE-TO-16' SCH 40 PIPE CFI C5.11 PT 01/27/95 295-08IPT-012 ACCEPT 02 066-132A CB16' SCH 40 PIPE LONGITUDINAL WELD CF1 C5.12 PT 01/27/95 295-08IPT-011 ACCEPT l l

                                                                                                                                                                                                                                                                                           ?

02-066-132A-LP 16" SCH 40 PIPE LONGITUDINAL WELD CFI C5.12 PT 01/27/95 295-08IPT-012 ACCEPT ) 02-066-134 16" SCH 40 PIPE-TO-ELBOW CF1 C5.11 PT 01/27/95 295-08IPT-011 ACCEPT 02-066-136A-CB 16" SCH 40 ELBOW BODY WELD - OUTSIDE CFl C5.12 PT 01/27/95 295-08IPT-010 ACCEPT RADIUS I 02-066-136A-LP 16" SCH 40 ELBOW BODY WELD - OUTSIDE CFI C5.12 PT 01/27/95 29548IPT-011 ACCEPT RADIUS 02-066-136B-CB 16" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 PT 01/27/95 295 08IPT-010 ACCEPT

   /                                                     RADIUS O         02-066-136B-LP 16* SCH 40 ELBOW BODY WELD - INSIDE                                                                                                                                                        CFI                     C5.12   PT  01/27/95 295-08IPT-011 ACCEPT RADIUS 02 066-140                                  16" SCH 40 PIPE-TO-VALVE                                                                                                                                      CFI                     C5.ll   PT  01/27/95 295-08IPT-009 ACCEPT 02-066-150                                  16" SCH 40 PIPE-TO-ELBOW                                                                                                                                      CF1                     C5.11   PT  01/27/95 295-08IPT-010 ACCEPT 02-066-151-CB 16' SCH 40 PIPE LONGTIUDINAL WELD                                                                                                                                                           CF1                     C5.12   PT  01/27/95 295-08IPT 009 ACCEPT 02466-151-LP 16" SCH 40 PIPE LONGITUDINAL WELD                                                                                                                                                            CFI                     C5.12   PT  01/27/95 295-08IPT010 ACCEPT 02-066-152                                  16" VALVE-TO-PIPE                                                                                                                                             CFI                     C5.11   PT  01/27/95 295-08IPT-009 ACCEPT 02-066-153-LP 16* SCH 40 PIPE LONGITUDINAL WELD                                                                                                                                                          CFI                      C5.12   PT  01/27/95 295-081PT-009 ACCEPT ZOhT : 69 02 069-090                              4* SCH 80s PIPE-TO 4' ELBOW                                                                                                                                      CFI                      C5.21   PT  02/02/95 295-08IPT-024 ACCEPT 02-069-090                              4' SCH 80S PIPE-TO 4' ELBOW                                                                                                                                      CFI                      C5.21   UT  02/08/95 295-08IUT-041 ACCEPT 02 069-100                              4' ELBOW-TO-4" SCH 80S PIPE                                                                                                                                      CFI                      C5.21   UT  02/08/95 295-08IUT-042 ACCEPT 02-069-100                              4" ELBOW-TO-4' SCH 80S PIPE                                                                                                                                      CFI                     C5.21    PT  02/02/95 295-08IPT-024 ACCEPT

( 02 469-110 4" SCH 80S PIPE-To-4" ELBOW CF1 C5.21 PT 02/02/95 295-08IPT-024 ACCEPT

   \/

02-069-110 4* SCH 80S PIPE-TO-4" ELBOW CFI C5.21 UT 02/08/95 295-08IUT-043 ACCEPT 04/21/95 Page 15

UNTT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS 7, . Southern California Edison

 /           T kj ISIID NO.                                                Area Description                                                                  Cat Item Method  Exam Dt Report._num     Result i

1 02-069-120 4* ELBOW-TO 4" SCH 80S PIPE CFI C5.21 PT 02/02/95 295-OSIPT-024 ACCEPT l 02-069-120 4" ELBOW-TO 4" SCH 80S PIPE CF1 C5.21 UT 02/08/95 295-08IUT-044 ACCEPT 02-069-130 4" SCH 80S PIPE-TO-4" ELBOW CFl C5.21 PT 02/02/95 295 08IPT-025 ACCEPT 02-069-130 4" SCH 80S PIPE-TO-4" ELBOW CFI C5.21 UT 02/08/95 295-08RTT-045 ACCEPT 02-069-140 4* ELBOW-TO# SCH 80S PIPE CFI C5.21 UT 02/08/95 295-08IUT046 ACCEPI' 02-069-140 4" ELBOW-TO-4" SCH 80S PIPE CFI C5.21 PT 02/02/95 295-08IPT-025 ACCEPT 02-069-150 4" SCH 80S PIPE-TO# ELBOW CFI C5.21 UT 02/08/95 295-081UT-047 ACCEPT 02-069-150 4" SCH 80S PIPE-TO-4" ELBOW CFI C5.21 PT 02/02/95 295-08IPT-025 ACCEPT 02-069-160 4" ELBOW-TO 4" SCH 80S PIPE CF1 C5.21 PT 02/02/95 295-08IPT 025 ACCEPT 02 069-160 4" ELBOW-TO-4" SCH 80S PIPE CF1 C5.21 UT 02/08/95 295-08IUI-048 ACCEPT 02-069-1610 3" SCH 160 PIPE TO-3" VALVE CFI C5.21 PT 02/10/95 295-081PT-039 ACCEPT 02-069-1610 3" SCH 160 PIPE-TO-3" VALVE CFI C5.21 UT 02/10/95 295-08IUT-028 ACCEPT  ! ( 02-069-1630 3" VALVE-TO-3" SCH 160 PIPE CFI C5.21 PT 02/10/95 295-08IPT-039 ACCEPT l 02 4 9-1630 3" VALVE-TO-3" SCH 160 PIPE CFI C5.21 UT 02/10/95 295-08IUT-027 ACCEPT l l 02-069-1640 3" SCH 160 PIPE-TO-3" ELBOW CFI C5.21 PT 02/03/95 295-08IPT-027 ACCEPT l 02-069-1640 l 3" SCH 160 PIPE-TO-3" ELBOW CFI C5.21 UT 02/08/95 295-081UT-055 ACCEPT l 02 069-1650 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 PT 02/03/95 295-08IPT-027 ACCEPT 02-069-1650 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-08IUT-056 ACCEPT 02 & 9-1670 3" SCH 160 PIPE-TO-ELBOW CFI C5.21 PT 02/03/95 295 08IPT-027 ACCEPT 02-069-1670 3" SCH 160 PIPE-TO-ELBOW CFI C5 21 UT 02/08/95 295-081UT-057 ACCEPT 02 & 9-1680 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-08IUT 058 ACCEPT l 02-069-1680 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 PT 02/03/95 295-08IPT 027 ACCEPT { 02-069-1720 3" SCH 160 PIPE-TO-3" ELBOW CFI C5.21 PT 02/03/95 295-08IPT-028 ACCEPT 02 4 9-1720 3" SCH 160 PIPE-TO-3* ELBOW CFI C5.21 UT 02/08/95 295-081UT-059 ACCEPT 02-069-1730 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-081UT-060 ACCEPT 02-069-1730 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 PT 02/03/95 295-08IPT-028 ACCEPT 02 069-1740 3" SCH 160 PIPE-TO-3" ELBOW CFI C5.21 UT 02/08/95 295-08IUT-061 ACCEPT

   ~

02-069-1740 3" SCH 160 PIPE-TO-3" ELBOW CFl C5.21 PT 02/03/95 295-08IPT-028 ACCEPT 02 4 9-1750 3" ELBOW-TO.3" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-08RTT-062 ACCEPT 04/21/95 Page 16

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

 ,m  Soutim California Edison ISIID NO.      Area Description                           Cat Item Method Exam Dt Report _,num     Result -

02 059-1750 3" ELBOW-TO-3" SCH 160 PIPE CFI C5.21 PT 02/03/95 295-08IPT 028 ACCEPT 02-069-1790 3" FLANGE-TO-3" SCH 160 PIPE CFI C5.21 UT 02/14/95 295-08IUT-096 ACCEPT 02-069-1790 3" FLANGE TO-3" SCH 160 PIPE CF1 C5.21 PT 02/14/95 295-08IPT-041 ACCEPT 02-069-1970 3" FLANGE-TO-3" SCH 160 PIPE CF1 C5.21 UT 03/10/95 295-08IUT-200 ACCEPT 02 4 69-1970 3" FLANGE-TO-3" SCH 160 PIPE CFl C5.21 PT 03/10/95 295-08IPT-078 ACCEPT 02-069-2050 3" X 2" REDUCER-TO-2" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-08IUT 074 ACCEPT 02-069-2050 3" X 2" REDUCER-TO-2" SCH 160 PIPE CF1 C5.21 PT 02/02/95 295-08IPT-021 ACCEPT 02-069-2060 2" SCH 160 PIPE-TO-2" VALVE CFI C5.21 UT 02/13/95 295-08IUT-035 ACCEPT 02-069-2060 2" SCH 160 PIPE-TO-2" VALVE CF1 C5.21 FT 02/13/95 295-08IPT 040 ACCEPT 02-069-2080 2" VALVE-TO-2" SCH 80S PIPE CFI C5.21 PT 02/13/95 295-08IPT-040 ACCEPT 02-069-2080 2" VALVE-TO-2" SCH 80S PIPE CFl C5.21 UT 02/13/95 295-08IUT-038 ACCEPT 02-069-2090 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 PT 02/02/95 295-08IPT-021 ACCEPT 02-069-2090 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 UT 02/08/95 295-081UT-068 ACCEPT 02-069-2100 2" ELBOW-TO-2" SCH 80S PIPE CFl C5.21 UT 02/08/95 295-081UT-069 ACCEPT 02-069-2100 2" ELBOW-TO-2" SCH 80S PIPE CF1 C5.21 FT 02/02/95 295-08IPT-021 ACCEPT 02-069-2350 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 UT 02/08/95 295-081UT-070 ACCEPT 02-069-2350 2" SCH 80S PIPE-TO-2" ELBOW CF1 C5.21 PT 02/03/95 295-08IPT-030 ACCEPT 02-069-2360 2" ELBOW-TO.2" SCH 80S PIPE CFI C5.21 PT 02/03/95 295-08IPT-030 ACCEPT 02-069-2360 2" ELBOW-TO-2" SCH 80S PIPE CFI C5.21 UT 02/08/95 295-08IUT-073 ACCEPT 02-069-2370 2" SCH 160 PIPE-TO-2" VALVE CFI C5.21 UT 02/14/95 295-081UT-036 ACCEPT 02-069-2370 2" SCH 160 PIPE-TO-2" VALVE CFI C5.21 PT 02/14/95 295-08IPT-043 ACCE'T P 02-069-2700 2" SCH 80S PIPE-TO-2" ELBOW CFl C5.21 UT 02/08/95 295-08RTT-071 ACCEPT 02-069-2700 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 PT 02/03/95 295-08IPT-029 ACCEPT 02-069-2710 2" ELBOW-TO.2" SCH 80S PIPE CFl C5.21 PT 02/03/95 295-08IPT-029 ACCEPT 1 02-069-2710 2" ELBOW-TO-2" SCH 80S PIPE CFI C5.21 UT 02/08/95 295-081UT-072 ACCEPT 02-069-2720 2" SCH BOS PIPE-TO-2" VALVE CFl C5.21 PT 02/h93 295-08IPT-042 ACCEPT 02-069-2720 2" SCH 80S PIPE-TO-2" VALVE CF1 C5.21 UT 02/14/95 295-081UT-029 ACCEPT 02-069-3040 GUIDE F-A Fl.20A VT-3 01/23/95 20-081VT-045 ACCEPT 02-069-3050 GUIDE & Y-STOP F-A Fl.20B VT-3 01/25/95 295-081VT-043 ACCEPT l 04/21/95 Page 17

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS

 -    Soutlen California E& son

! 3 \J ISIID NO. Area Description Cat Item Metbod Exam Dt Report _ num Result 02-069-3060 GUIDE F-A Fl.20A VT-3 Ol/25/r 5 295-081VT-044 ACCEPT 02-069-3220-F ANCHOR STRAP F-A Fl.20B VT-3 01/19/95 295-081hT-037 ACCTFE 02-069-3220-I INTEGRALLY WELDED ANCHOR STRAP C-C C3.20 PT 01 19/95 295-08IPT 003 acchr 02-069-3580-F SWAY STRUT F-A Fl.20A VT-3 01/19/95 295-08IVT-050 ACCEPT 02 069-3580-1 SWAY STRUT W/ DUMMY STUB (SNUBBER C-C C3.20 PT J1/19/95 295-08IPT-004 ACC15 REPLACED DCP 2-6683.lSM) 02-069-3590 GUIDE F-A F1.20B VT-3 01/19/95 295-08IVT-038 ACCEPT 02-069-3620 Y-STOP F-A Fl.20A VT-3 01/19/95 295-081VT-038 ACCEPT I 02-069-3720 GUIDE F-A F120B VT-3 01/19/95 295-081VT-036 ACCEPT 02-069-3760 GUIDE F-A Fl.20B VT-3 01/23/95 295-081VT-046 ACCEPT 02-069-3770-F Y-STOP F-A Fl.20A VT-3 01/23/95 295-08IVT-047 ACCEPT 02-069-3870 Y-STOP F-A F1.20A VT-3 01/23/95 295-081VT-048 ACCEPT 02-069-390 4" SCH 80S PIPE-TO-4* ELBOW CFI C5 21 PT 02/02/95 295-08IPT 022 ACCEPT 02-069-390 4" SCH BOS PIPE-TO4" ELBOW CFI C5.21 UT 02/08/95 295-08IUT-049 ACCEPT 02-069-3930-F 3-WAY STOP F-A F1.20B VT-3 01/23/95 295-08IVT-049 ACCEPT 02-069-3930-1 3-WAY STOP W/ INTEGRALLY WELDED LUGS C-C C3.20 PT 01/24/95 295-08IPT-018 ACCEPT 02-069-400 4* ELBOW-TO-4" SCH 80S PIPE CFI C5.21 UT 02/08/95 295-08IUT-050 ACCEPT 02-069 400 4" ELBOW-TO-4' SCH 80S PIPE CF1 C5.21 FI 02/02/95 295-08IPT-022 ACCEPT 02-069-410 4" SCH 80S PIPE-TO-4* ELBOW CFI C5.21 UT 02/08/95 295-081UT-051 ACCEPT 02-069-410 4* SCH 80S PIPE-TO-4" ELBOW CFI C5.21 PT 02/02/95 295-08IPT-022 ACCEPT 02-069420 4" ELBOW-TO 4" SCH 80S PIPE CFI C5.21 UT 02/08/95 295-08IUT-052 ACCEPT 02-069420 4" ELBOW-TO-4" SCH 80S PIPE CFI C5.21 PT 02/02/95 295-081PT-023 ACCEPT 02-069 430 4' SCH 80S PIPE-TO.4" ELBOW CFI C5.21 PT 02/02/95 295 08IPT-023 ACCEPT 02-0694 30 4" SCH BOS PIPE-TO-4" ELBOW CFI C5.21 UT 02/08/95 295-08IUT-053 ACCEPT 02-069440 4" ELBOW-TO4* SCH 80S PIPE CFI C5.21 UT 02/08/95 295-08IUT 054 ACCEPT 02-069-440 4' ELBOW-TO-4" SCH 80S PIPE CF1 C5.21 PT 02/02/95 295-081PT-023 ACCEPT 02-069-810 2* SCH 80S PIPE-TO-ELBOW CFI C5.21 PT 02/03/95 295-08IPT-031 ACCEPT  ! /,,h 'w) 02-069-810 2* SCH SOS PIPE-TO-ELBOW CFl C5.21 UT 02/08/95 295-08IUT-067 ACCEPT 02-069-820 2* ELBOW-TO-2" SCH 80S PIPE CF1 C5.21 PT 02/03/95 295-08IPT-031 ACCEPT j l 1 04/2I/95 Page 18

l UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS  !

 ,    Southern Cahfarnia Edson l

Y l ISIID NO. Area Description Cat Item Method Exam _Dt Report num Result , 02-069-820 2" ELBOW-TO-2" SCH 80S PIPE CFI C5.21 UT 02/08/95 295-081UT-066 ACCEPT 02-069-890 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 PT 02/03/95 295-08IPT-032 ACCEPT 02-069-890 2" SCH 80S PIPE-TO-2" ELBOW CFl C5.21 UT 02/08/95 295-081UT-065 ACCEPT 02-069-900 2" ELBOW-TO-2" SCH 80S PIPE CFl C5.21 UT 02/08/95 295-08IUT-064 ACCEPT 02-069-900 2" ELBOW-TO-2" SCH 80S PIPE CFI C5.21 PT 02/03/95 295-08IPT-032 ACCEPT 02-069-910 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 UT 02/08/95 295-081UT-063 ACCEPT 02-069-910 2" SCH 80S PIPE-TO-2" ELBOW CFI C5.21 PT 02/03/95 295-08IPT 032 ACCEPT 02 069-920 2" ELBOW-TO-2" SCH 160 PIPE CFI C5.21 UT 02/08/95 295-08IUT-075 ACCEPT 02-069-920 2" ELBOW-TO-2" SCH 160 PIPE CFI C5.21 PT 02/03/95 295 08IPT-032 ACCEPT 02-069 950 2" VALVE-TO-2" SCH 160 PIPE CFI C5.21 UT 02/14/95 295-08IUT-037 ACCEPT 02-069-950 2" VALVE TO-2" SCH 160 PIPE CFl C5.21 FT 02/14/95 295-081PT-044 ACCEPT (~] ZONE : 73 02 073-069 8" SCH 140 PIPE-TO-VALVE CF1 C5.11 UT 02/13/95 295-081UT-093 ACCEPT 02-073-069 8" SCH 140 PIPE-TO VALVE CFI C5.11 PT 02/10/95 295-08IFT-038 ACCEPT 02-073-071 VALVE-TO-8" SCH 140 PIPE CFI C5.ll UT 02/13/95 295 081UT-094 ACCEPT 02-073-071 VALVE-TO-8" SCH 140 PIPE CFI C5.11 FT 02/10/95 295-08IPT-038 ACCEPT 02-073-072 8* SCH 140 PIPE-TO-PENETRATION NO. 51 CFI C5.11 UT 02/13/95 295-081UT-095 ACCEPT 02-073-072 8" SCH 140 PIPE-TO-PENETRATION NO. 51 CF1 C5.11 PT 02/10/95 29508IPT 038 ACCEPT 02-073-072A PENETRATION NO. 51-TO-8" SCH 140 PIPE CFI C5.Il UT 02/23/95 295-08IUT-119 ACCEPT ' 02-073-072A PENETRATION NO. 51-TO-8" SCH 140 PIPE CFI C5.ll FI 0'J22/95 295-08IPT-056 ACCEPT  ! 02-073-072B 8" SCH 140 PIPE-TO-VALVE S21204MUO75 CFl C5.11 UT 024V95 295-081UT-118 ACCEPT 02-073-072B 8" SCH 140 PIPE-TO VALVE S21204MUO75 CFI C5.11 PT 02/22/95 295-08IPT 056 ACCEPT 02-073 141 PENEIRATION NO. 50-TO-8* SCH 140 PIPE CFI C5.11 UT 02/16/95 295-08IUT-084 ACCEPT 02-073-141 PENETRATION NO. 50-TO-8* SCH 140 FIPE CFl C5.11 PT 02/15/95 295-08IPT-046 ACCEPT 02-073-142 8" SCH 140 PIPE-TO-VALVE CFI C5.11 PT 02/15/95 295-08IPT-050 ACCEPT s 02-073-142 8' SCH 140 PIPE-TO-VALVE CFI C5.11 UT 02/16/95 295-08IUT-085 ACCEPT , C 02-073-142 8" SCH 140 PIPE-TO-VALVE CFI C5.11 PT 02/15/95 295-08IPT-045 REJECT l 02-073-165 PENETRATION NO. 49-TO-8" SCH 140 PIPE CF1 C5.11 UT 02/16/95 295-08IUT-080 ACCEPT 04/21/95 Page 19

UNTT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS Southern California Edison g J ISI ID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-073-165 PENETRATION NO. 49-TO-8" SCH 140 PIPE CFl C5.11 PT 02/15/95 295-08IPT-048 ACCEPT 02-073-166 8" SCH 140 PIPE-TO-ELBOW CFI C5.11 UT 02/16/95 295-081UT-081 ACCEPT 02-073-166 8' SCH 140 PIPE-TO-ELBOW CFI C5.11 PT 02/15/95 295 081PT-048 ACCEPT 02 073-167 8" SCH 140 ELBOW-TO. PIPE CF1 C5.11 UT 02/16/95 295-08IUT-082 ACCEPT 02-073-167 8" SCH 140 ELBOW-10-PIPE CF1 C5.11 PT 02/15/95 295-081PT-048 ACCEPT 02-073-168 8" SCH 140 PIPE-TO VALVE CFI C5.11 PT 02/15/95 295-08IPT-048 ACCEPT 02-073-168 8" SCH 140 PIPE-TO-VALVE CF1 C5.11 UT 02/16/95 295-08IUT-083 ACCEPT 02-073-187 8" SCH 140 PIPE-TO-VALVE CF1 C5.11 PT 02/06/95 295-08IPT-033 ACCEPT 02 073-187 8" SCH 140 PIPE-TO VALVE CF) C5.1i UT 02/06/95 295-08IUT-030 ACCEPT 1 02-073-189 VALVE-TO-8" SCH 140 PIPE CF) C5.Il UT 02/06/95 295-08IUT-031 ACCEPT 02-073-189 VALVE-TO-8" SCH 140 PIPE CFl C5.ll PT 02/06/95 295-08IPT-033 ACCEPT 02-073-190 8" SCH 140 PIPE-TO-ELBOW CFI C5.11 PT 02/06/95 295-08IPT-033 ACCEPT 02-073-190 8" SCH 140 PIPE-TO-ELBOW CFI C5.Il UT 02/06/95 295-08IUT 032 ACCEPT I 02-073-191 8" SCH 140 ELBOW-TO-PIPE CFI C5.11 UT 02/06/95 295-08IUT-033 ACCEPT 02-073-191 8" SCH 140 ELBOW-TO-PIPE CF1 C5.11 FT 02/06/95 295 081PT-033 ACCEPT 02-073-192 8" SCH 140 PIPE-TO-PENETRATION NO. 48 CF1 C5.11 FT 02/06/95 295-08IPT-033 ACCEPT 02-073-192 8" SCH 140 PIPE-TO-PENETRATION NO. 48 CFI C5.11 UT 02/06/95 295-08IUT-034 ACCEPT 02 073-193 (SEE SKETCH BELOW) CF1 C5.11 UT 02/16/95 295-081UT-076 ACCEPT 02-073-193 (SEE SKETCH BELOW) CF1 C5.11 FT 02/15/95 295-081PT-049 CCEPT 02-073-194 8" SCH 140 PIPE-TO-ELBOW CF1 C5.11 FT 02/15/95 295-08IPT 049 ACCEPT 02 473-194 8* SCH 140 PIPE-TO-ELBOW CF1 C5.11 UT 02/16/95 295-08IUT-077 ACCEPT 02 073-195 8" SCH 140 ELBOW TO-PIPE CFI C5.11 PT 02/15/95 295-08IPT 049 ACCEPT 02 073-195 8" SCH 140 ELBOW-TO-PIPE CFI C5.11 UT 02/16/95 295-08IUT-078 ACCEPT 02-073-196 8" SCH 1-40 PIPE-TO-VALVE CF1 C5.11 PT 02/15/95 295-08IPT-049 ACCEPT 02-073-l % 8" SCH 140 PIPE-TO-VALVE CFl C5.ll UT 02/16/95 295-08IUT-079 ACCEPT 02-073-234-1 Y-STOP W/ INTEGRALLY WELDED LUGS C-C C3.20 PT 01/12/95 295-08IFT-001 ACCEPT 02-073-241-F GUIDE & Y-STOP F-A Fl.20B VT-3 01/24/95 295-081VT-041 ACCEPT 02-073-241-1 GUIDE & Y-STOP W/LVTEGRALLY WELDED C-C C3.20 PT 01/24/95 295-08IPT-020 ACCEPT LUGS 04/21/95 Page 20

UNIT 2 CYCLE 8 EI COMPLETED EXAMINATIONS Southern California E& son f ) LJ ISI ID NO. Area Description Cat Item Method Exam _Dt Report _num Result 02-073-242-F Y-STOP F-A Fl.20A VT3 01/24/95 295-OSIVT 041 ACCEPT 02-073-242-I Y-STOP W/ INTEGRALLY WELDED LUGS C-C C3.20 PT 01/24/95 29548IPT-019 ACCEPT 02 073-243-F SWAY STRUT F-A Fl.20A VT-3 01/24/95 295-081VT-040 ACCEPT ZONE : 75 02-075-059-F GUIDE & AXIAL STOP F-A F1.20B VT-3 01/30/95 295081VT-053 ACCEPT 02-075-059-I GUIDE & AXIAL STOP W/ INTEGRALLY C-C C3.20 PT 01/30/95 295-08IPT-035 ACCEPT WELDED LUGS & CURVED PLATE 02-075-060-F VARIABLE SPRINGS F-A Fl.20C VT-3 01/24/95 295-081VT-039 ACCEPT 02-075-060-1 VARIABLE SPRINGS W/ INTEGRALLY WELDED C-C C3.20 PT 01/24/95 295-08IPT-016 ACCEPT LUGS 02-075-062-F SNUBBER F-A F1.20C VT-3 02/02/95 295-081VT-059 ACCEPT ZONE : 76 k 02-076-141 12" SCH 40 FIANGE-TO-REDUCER CF1 C5.11 PT 02/07/95 295-OSIPT-034 ACCEPT 02-076-141 12" SCH 40 FLANGE-TO-REDUCER CF1 C5.11 UT 02/07/95 295-08RTT-039 ACCEPT 02-076-142 REDUCER BODY WEC $ CF1 C5.12 UT 02/07/95 295-08RTT040 ACCEPT , 02-076-142 REDUCER BODY WELI[ CFI C5.12 PT 02/07/95 295 081PT-034 ACCEPT 1 ZONE : 78 - 02-078-080-F GUIDE & AXIAL STOP F-A F1.20B VT-3 02/02/95 295-08IVT 057 ACCEPT l 02-078-080-1 GUIDE & AXIAL STOP W/ INTEGRALLY C-C C3.20 PT 01/24/95 29548IPT-017 ACCEPT , WELDED LUGS l 02-078-101 VARIABLE SPRING HANGER (FORMERLY F-A F1.20C VT-3 01/31/95 295-08IVT-052 ACCEPT S2 CS-004-H-075) 02-078-110A-CB12" SCH 40 PIPE LONGIIUDINAL WELD CFI C5.12 UT 01/31/95 295-081UT-013 ACCEPT 02-078-110A-CB12" SCH 40 PIPE LONGTIUDINAL WELD CFI C5.12 PT 01/26/95 295-08IPT-008 ACCErh 02-078-110A-H 12" SCH 40 PIPE LONGITUDINAL WELD CFI C5.12 PT 01/26/95 295-08IFT-005 ACCEPT X

p 02-078-110A-H 12" SCH 40 PIPE LONGTIUDINAL WELD CF1 C5.12 UT 01/31/95 295-08IUT-001 ACCEPT x

l

 \)u 02-078-111       12" SCH 40 PIPE-TO-FLANGE               CFI   C5.11   PT  01/30/95 295-08IPT-013 ACCEPT 04/21/95                                                                                      Page    21

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS ,- ss Southern California Edison ( ) V l ISIID NO. Area Description Cat Item Method Eram_Dt Report _num Result 02-078-111 12* SCH 40 PIPE-TO-FLANGE CFI C5.11 UT 0101/95 295-081UT-024 ACCEPT 02-078-111 A-CB 12' SCH 40 PIPE LONGTTUDINAL WELD CFI C5.12 UT 01/31/95 295-081UT-003 ACCEPT 02-078-111A-CB12" SCH 40 PIPE LONGITUDINAL WELD CFI C5.12 PT 01/26/95 295-08IPT-006 ACCEPT 02-078-Ill A-H 12" SCH 40 PIPE LONGTIUDINAL WELD CFI C5.12 PT 01/30/95 295-08IPT-013 ACCEPT X 02-078-Illa-H 12" SCH 40 PIPE LONGTIUDINAL WELD CFl C5.12 UT 01/31/95 295-081UT-002 ACCEPT X

                                                                                                                  ]

02-078-112 12" SCH 40 PIPE-To-ELBOW CFI C5.11 PT 01/26/95 295-08IPI.006 ACCEPT 02-078-112 12" SCH 40 PIPE-TO-ELBOW CFI C5.ll UT 01/31/95 295-08IUT-025 ACCEPT 02-078-113 12" SCH 40 ELBOW-TO-PIPE CFI C5.11 UT 01/31/95 295-081UT-004 ACCEPT  ; l 02-078-113 12" SCH 40 ELBOW-TO-PIPE CFI C5.11 UT 01/31/95 295-08RTT-005 ACCEPT 02-078-113 12" SCH 40 ELBOW-TO-PIPE CFl C5.11 PT 01/26/95 295-08IPT-005 ACCEPT i [2 078-115 12" SCH 40 PIPE-TO-TEE CFl C5.11 UT 01/31/95 295-08RTT-014 ACCEPT f h 02-078-115 12" SCH 40 PIPE-TO-TEE CFI C5.11 PT 01/26/95 295-08IPT-008 ACCEPT 02-078-116-DS 12"X 12*X 8" TEE BODY WELD - LONG SEAM CF1 C5.12 PT 01/26/95 295-08IPT-007 ACCEPT 02-078-116-DS 12*X 12"X 8" TEE BODY WELD - LONG SEAM CFI C5.12 UT 01/31/95 295-08RTT-009 ACCEPT 02-078-116-US 12"X 12"X 8' TEE BODY WELD . LONG SEAM CFl C5.12 UT 01/31/95 295-081UT-Oll ACCEPT 02-078-116-US 12*X 12"X 8" TEE BODY WELD-LONG SEAM CFI C5.12 PT 01/26/95 295-08IPT-008 ACCEPT 02-078-Il6A-US 12'X 12*X B" TEE BODY WELD - SHORT SEAM CFI C5.12 PT 01/26/95 295-08IPT-008 ACCEPT 02-078-116A-US 12*X 12*X 8" TEE BODY WELD - SHORT SEAM CFl C5.12 UT 01/31/95 295-08IUT-012 ACCEPT 02-078-116B-DS 12"X 12"X 8* TEE BODY WELD - SHORT SEAM CFI C5.12 PT 01/26/95 295-08IPT-007 ACCEPT 02-078-116B-DS 12"X 12"X 8" TEE BODY WELD - SHORT SEAM CFI C5.12 UT 01/31/95 295-08IUT-010 ACCEPT 02-078-117A-DS 12" SCH 40 ELBOW BODY WELP 11TTSIDE CFI C5.12 UT 01/31/95 295-081UT-007 ACCEPT RADIUS 02-078-117A-DS 12" SCH 40 ELBOW BODY WELD - OUTSIDE CFI C5.12 PT 01/26/95 295-08IPT-005 ACCEPT RADIUS 02-078-117A-US 12" SCH 40 ELBOW BODY WELD - OUTSIDE CFI C5.12 PT 01/26/95 295-08IPT-006 ACCfb RADIUS /9 02-078-117B-DS 12" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 UT 01/31/95 295-081UT-008 ACCEPT Cl RADIUS 02-078-117B-DS 12" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 PT 01/26/95 295-08IPT-005 ACCEPT 04/21/95 Page 22

4 UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS Southern Califomia Edison ! \ V ISI ID NO. Ares Description Cat Item Method Exam _Dt Report _num Result RADIUS 02-078-117B-US 12" SCH 40 EL30W BODY WELD -INSIDE CFI C5.12 PT 01/26/95 295-08IPT-006 ACCEPT RADIUS 02-078-117B-US 12" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 ITT 01/31/95 295-08IUT-006 ACCEPT RADIUS 02-078-135 12" SCH 40 TEE-TO-ELBOW CFl C5.11 PT 01/26/95 295-08IFT-007 ACCEPT 02-078-135 12" SCH 40 TEE-TO. ELBOW CFI C5.ll UT 01/31/95 295-08IUT-019 ACCEPT 02-078-137A-CB12" SCH 40 ELBOW BODY SEAM - OUTSIDE CFI C5.12 PT 0180/95 295 08IPT-014 ACCEPT RADIUS 02 078-137A-CB12" SCH 40 ELBOW BODY SEAM - OUTSIDE CFI C5.12 ITT 01/31/95 295-08RTT-015 ACCEPT I RADIUS l i 02-078-137A-H 12* SCH 40 ELBOW BODY SEAM - OITTSIDE CFI C5.12 PT 01/26/95 295-08IPT-007 ACCEPT X RADIUS 1 02 078-137A-H 12" SCH 40 ELBOW BODY SEAM - OUTSIDE CFI C5.12 UT 0181/95 295-081UT017 ACCEPT eg X RADIUS k I d 02478-137B-CB 12" SCH 40 ELBOW BODY WELD -INSIDE CF1 C5.12 PT 01/30/95 295-08IPT 014 ACCEPT RADIUS 02 078-137B-CB 12" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 UT 01/31/95 295-08RTT-016 ACCEPT  ; RADIUS l 02 078-137B-H 12" SCH 40 ELBOW BODY WELD -INSIDE CFI C5.12 PT 01/26/95 295-08IPT-007 ACCEPT X RADIUS l 02 078-137B-H 12" SCH 40 ELBOW BODY WELD -INSIDE CFl C5.12 ITT 0181/95 295-081UT018 ACCEPT  ! X RADIUS l 02-078-140 12" SCH 40 ELBOW-TO-PIPE CFl C5.11 UT 0181/95 29548IUT-020 ACCEPT I 02-078-140 12" SCH 40 ELBOW-TO-PIPE CF1 C5.11 PT 0180/95 295-08IPT-014 ACCEPT 02-078-140A-CB12" SCH 40 PIPE LONG17UDINAL WELD CFI C5.12 PT 0180/95 295-08IFT-015 ACCEPT  ; 02-078-140A-H 12" SCH 40 PIPE LONGITUDINAL WELD CFI C5.12 PT 0180/95 295-08IPT-014 ACCEPT x l l 02-078-140A-H 12" SCH 40 PIPE LONGITUDINAL WELD CF1 C5.12 UT 01/31/95 295-081UT-023 ACCEPT X ' 02-078-145 12" SCH 40 PIPE-TO-12"X 10" REDUCER CFl C5.11 PT 01/30/95 295-08IPT-015 ACCEPT 02-078-146-CB 12" X 10" SCH 40 ECCENTRIC REDUCER BODY CFI C5.12 UT 01/31/95 295-08IUT-021 ACCEPT l V SEAM 02-078-146-CB 12" X 10" SCH 40 ECCENTRIC REDUCER BODY CFI C5.12 FT 01/30/95 295-08IPT-015 ACCEPT i 04/21/95 Page 23 l l

UNIT 2 CYCLE 8 ISI COMPLETED EXAMINATIONS __ Sou:hern California Edison I ,)

 \_/

ISI ID NO. Area Description Cat Item Method Exam _Dt Report _num Result SEAM 02 078-146-HX 12" X 10" SCH 40 ECCENTRIC REDUCER BODY CFI C5.12 UT 01/31/95 295-08IUT-022 ACCEPT SEAM 02-078-146-HX 12" X 10' SCH 40 ECCENTRIC REDUCER BODY CFI C5.12 PT OlG0/95 295-08IPT-015 ACCEPT SEAM 02-078-150 12* SCH 40 REDUCER-TO-VALVE CFI C5.11 UT 0101/95 295-08IUT-026 ACCEPI 02 078-150 12* SCH 40 REDUCER-TO-VALVE CFI C5.11 PT 0100/95 295-08IPT-015 ACCEPT 02-078-2130 Y-STOP F-A Fl.20A VT-3 01/31/95 295-08IVT-051 ACCEPT 02-078-2140 GUIDE F-A Fl.20A VT-3 01G1/95 295-081VT-055 ACCEPT 02-078-2160 Y-S1DP F-A Fl.20A VT-3 01G1/95 295-081VT-055 ACCEPT 02-078-2170 Y-STOP F-A F1.20A VT-3 01G1/95 295-08IVT-054 ACCEPT ZONE : 81 (3 l 02-081-001 GIRTH WELD- SHELL END C-A Cl.10 UT 03/08/95 295-081UT-198 ACCEPT ( 02-081-002 GIRTH WELD- FLANGE END C-A C1.10 UT 03/08/95 295-081UT-199 ACCEPT L./ 04/21/95 Page 24

                                                                    ~

e-f i

\"/

UNIT 2 CYCLE 8 SYSTEM PRESSURE TESTS i I PRESSURE TEMPERATURE EXAM MVSTEM Pl. ANT LM ATION REQT/AM.ncia D ROT /ACT.9F DA3E [ A. SYSTEM LEAKAGE TESTS: RCS PIPING INSIDE - REACTOR COOLANT (1201) ' CONTAINMENT 2250 i 25/2254 2.350/478 4/14/95 , B. SYSTEM FUNCTIONAL TESTS: LOW PRESSURE PUMP NO.1/MP015 NOP /165 NOT2/AMB' 3/01/95 SAFETY INJECTION 1204 - LOW PRESSURE SAFETY PUMP NO.2/MPOl6 NOP/180 NOT/AMB 3/10/95 INJECTION 1204. HIGH PRESSURE SAFETY PUMP NO.1/MP017 NOP/1010 NOT/AMB 12/8/94 INJECTION 1204 i HIGH PRESSURE SAFETY PUMP NO. 2/MP018 NOP/1650 NOT/AMB 11/17/94 - INJECTION 1204 HIGH PRESSURE SAFETY PUMP NO. 3/MP019 NOP/1550 NOT/AMB 10/27/94 INJECTION 1204 ['~} CONTAINMENT PUMP NO.1/MP012 NOP/247 NOT/AMB 4/12/95 SPRAY 1206 CONTAINMENT PUMP NO. 2/MP013 NOP/247 NOT/AMB 4/12/95 SPRAY 1206 C. SYSTEM INSERVICE TEST: INSIDE CONTAINMENT NOP/2250-RCS' NOT/2545-RCS 2/11/95 CHEMICAL & VOLUME CONTROL 1208 l I MAIN STEAM 1301 INSIDE CONTAINMENT NOP/1005 NOT/547 - 2/11/95 STEAM GEN.ME088/ME089 MAIN FEEDWATER 1305 INSIDE CONTAINMENT NOP/1066 NOT/270 2/11/95 PENETRATIONS 28 AND 29 l AUXILIARY INSIDE CONTAINMENT NOP/984 NOT/543 4/14/95  ! FEEDWATER l'05 l l AUXILIARY CONTAINMENT NOP/1385 NOT/544 4/14/95 FEEDWATER 1305 ISOLATION VALVES 2HV4715 & 2HV4730 I 8 Normal Operating Pressure ( 2 3 Normal Operating Temperature Ambient or Room Temperature Reactor Coolant System

SAN ONOFRE NUCLEAR GENERATING STATION

SUMMARY

REPORT UNIT 2 - O . %../ ATTACHMENT 10 FORM NIS-2 OWNER'S REPORTS FOR REPAIRS OR REPLACEMENTS i B B k b e Y I e O .

         .' s 7,
                               , .,.            .           . . .          +-          -           -         -

n -.

                                                                                                                                          =-
                                                                                                                                                 , ~ , - ,           .      -   - -                      .
    ,              +     ,                                                                             -3                                                        ,                   .        ,_     .
                                                      .;                                                                          m                                                                     j
  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS
         "'       ^

As nagered by en reestdess er the Asas ced. Sesmas n -

< 1 4 .

i{ b ~ Sheet 1 of 2

       ? U.F               fl,'        . Owner: Seathern Califorale Edises Ceepany -                      .

Unit: - 2/3 224d Walent Grove Avense, Rosemead, CA 91770 Treveler: See Block 7 RS: See Eleck 7 ,

2. Plant: San Onofre Naclear Generatin8 Staties P&ID: 'N/A- I P.O.Bes 128, Sam th==8e CA 926744128 . N-5: N/A ** '

1 3.' . Work Perfonned by: Seathern Califerala Edisse Ceepany Type code Symbol Stamp: 1N/A  ! Authortzehoa No: N/A - 2

                   -      " d.           Identi6cetion of System:               N/A                                                    Espantaan Date:                        'N/A                       !
                                                                                                                                                                                                       ~l'
5. (a) Applieeble Construedon Code: ASME Section III, Class 1,197d Edities, '7d Addenda, Code Cases: Nome . ~

(b) Applicable Edition of Seenon XI UtMad for Repairs or Replacements.1977 Edities, S'79 Addenda j

6. Ideati6 cation of C - - Repelred or Replaced and Replacement 't __, _ - j!

RePoised, ASME ) Name of Naras of Meaufacturer National - Other Year Repleeed,or . Code l Component Meaufacturer Serial No. ' Board No. Identi6 cation Buik Replaa=====* Stamped l Yes/No .! Madamcel Snubber Paci6c 120 N/A RSO 386146 N/A - No  ! PSA 100 Scienti6c Torque Carriet (ehell) Paci6e Seteau6c Heat A24092 N/A Port 1801415 N/A  ? ,' No  ! US Steel Trese N-2403 j Torque Carrier (hub) - Paci6c Scienti6e Heat AS096785 N/A Pan 1801416 N/A Replesoment No { Republic Steel Trees N-2522-H  : Pinion Geer . Posi6c Seienn6s Hem:45638 N/A Pen 1801418 N/A Replesoment - No l E.M. 3ergensen Tsees N-23al-B Meehemsel smubber Paci6c 122 N/A RS0 322946 N/A - No 1 PSA 100 scienti6c I 1 Tosque Carrier (ehell) Paci6c Scienti6c Heat A24092 N/A Port 1801415 N/A Replacement No j

          *4.'

(C US Steel Trees N 2403 s Torque Carrier (hub) Paci6c Seisati6c HeatA8096785 N/A Pen 1801416 N/A * ,' No l Republic Steel Trees N-2522-H l Teleseaping Cylinder Paci6e Scienti6e Heat B92372 N/A Part 1801434 N/A *

                                                                                                                                                                       .'                 No US Steel                                              Trees N-1387 C Pinion Geer                      Paci6c Scientinc     Heat 45638                 N/A         Part 1801418                  N/A       Replacement            No           'I E.M. Jorgensen                                            Trace N 2302-3                                                              .l MechemselSnubber                         Paci6c       297                        N/A         RSO 386146                    N/A              -               No PSA 106                                 Scienti6c Telescoping Cylinder              Paci6c Scienti6c     Heat 892372                N/A         Pen 1801434                   N/A       Replacement            No
                                .                                   US Stes!                                               Trece N-1387-C
7. Description of Work: ,

1

                                        'Ihe failed enubbers were shipped to Paci6e Scleati6c for testing, diseseeably,lampaction, rebuil(tag and testing (Referense SCE PO                              l 61A56014). '!he Sectaon XI Travelers were lost, NCR O-1029 was generened to identify this. The listing below ideati6es the                                      i applicable SCE document numbers.                                                                                                                             .l SN          NCR       - Traveler         MERS          SN      NCR           Traveler           MERS                                         5 120          2-1818    802-12146         56046          130     2-1816     802-11046              55946 122          2-1811    SO2-112-86*       558-86        297      2 1824     802-127-86             578-86 124          2-1823    802-125-86        577-86        310      2-1814     802-117-86             576-86 127          2 1812    S02-114-86*       557-86        313      2 1800     802 13446*             57546 Nopes of thens travelers were evennaelly found.
8. Tests Conducted: System'Leekage [] System Functional [] System laservice [] Hydrostatic [] Pneumatic [] Oiber []

g Pressure: N/A psig Temp: N/A 'F ij , "

         .w
                           - Note:      Supplemental sheets la the form of lists, sketches, or drawings may be used provided (I) size is 8 % in. x 1I lo., (2) Informanon la hems 1 through 6 on this report is included on each ehest, (3) each ehest is numbered and the number of sheets le recorded et the top of this form. and to each ehese le lakieled and dated by the Owner er Owner's Desinose sad the AIA.
                                                                                                                                                                                                  /

j

FORM NIS-2 (back) .

9. Remarks: None.

(Applicable Manufacturer's Data Repons to be enached) CERTIFICATE OF COMPLIANCE We cernfy that the statements made in the report m correct and this reotacement conforms to the nales of the ASME Code, Section XI. Type Code Symbol Stamp: N/A Certi6cate of Authorization No: N/A Expiradon Date: N/A Signed: /[/ .Sovervis'or ASME Codes Enrineer Date: 19 cKnder cuner'TDuignes, Title CERTIFICATE OF INSPECTION I, se undersigned holding a valid commission issued by the Nations! Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwrirht Mutual Insurance Comnany (Feetory Mutual Enrineerine Association) of b'orwood. Massacbtocets have inspected the components described in this Owner's Repon during the period 8426/9//- to 6// ::r/942 .and state that to the best of my knowledge and belief, the Owner has performed examinations ind'talien cor'rective inusures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranry, expressed or implied, concerning the examinations and corrective rosasuru described in this owner's Report. Funbermore, neither the Inspector nor his employer shall be .m s liabis in any manner or any personalinjury or propeny damage or a loss of any Idnd arising from or connected with this inspeedon. ( ' MfWf8#y1 Commissions b California b I'spector's n Signatpfs N s (National Board, State, Province, and Endorsements } Date _ /Atk i 19 h

       /                                                                .

6

                                      ~

1 FORM NIS.2 OWNER'S REPORT IOR REPAIRS OR REPLACEMENTS As Required by dw Provhs of the ASME Code Esdjan XI

     /                                                                                                        Sheet 2 of 2
1. Owner: Southern California Edison Compacy Unit: 2/3 2244 Walnut Grove Avenue, Rosemead, CA 91770 Traveler: See Block 7 RS: See Block 7 I
2. Plant: San Onofre Nuclear Generating Station P&ID: N/A s.

P.O. Box 128, San Clemente, CA 92674-0128 N-5: N/A

3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identi6cadon of System: N/A Expiration Date: N/A
5. (a) Applicable constructi on Code: ASME Swtion HI, Class 1,1974 Edition, '74 Addenda, Code Cases: None (b) Applicable Edidon of Section XI Utilized for Repairs or Replacements: 1977 Edition, S'79 Addenda i
6. Idendfication of Components Repaired or Replaced and Replacement Components:

Repaired, ASME , Name of Name of Manufacturer National Other Yur Repisce<!, or . Code l Component Manufacturer Serial No. Board No. Idendfication Built Replacement Stamped Yes/No j Medanicts) Snubber Pacinc 124 N/A RSO 3861-86 N/A - No l PS A 100 scientific Torque Carrier (shell) Pacific Scienufic Heat A24092 N/A Part 1801415 N/A Replacement No US Steel Trace N-2403 Torque Carrier (hub) Pacine Scienti6c Heat A8096785 N/A Pan 1801416 N/A Replacement No j Republic Steel Trace N-2522-H Telescoping Cylinder Paci6c Scientific Heat B92372 N/A Part 1801434 N/A Rep!acement No US Steel Trace N-1387-C j Pmion Gear Paci6c Scientine Heat 45638 N/A Part 1801418 N/A Replacement No E.M. Jorgensen Trace N-2302-B Mechanical Snubber Paci6c 127 N/A RSO 3229-86 N/A - No l PSA 100 Scienti6c l Torque Carrier (shell) Paci6c Sciendfic Heat A24092 N/A Pan 1801415 N/A Replacement No US Steel Trace N-2403 l Torque Carrier (hub) Pacific Scienufic Heat A8096785 N/A Part 1801416 N/A Replacement No j Republic Steel Trace N-2522-H Pinion Gear Pacine Scienti6c Heat 45638 N/A Pan 1801438 N/A Replacement No E.M. Jorzensen Trace N-2302-B Mechanical snubber Pacific 130 N/A RSO 3473-86 N/A - No PSA 100 Scienti6c Torque Carner (shell) Pacific Scientinc Heat A24092 N/A Pan 1801435 N/A Replacement No US Steel Trace N-2403 Torque Carrier (hub) Paci6c Scient6c Heat A8096785 N/A Part !801416 N/A Replacement No Republic Steel T:see N-2522-H Pmion Gear Pacine Scientinc Heat 45638 N/A Part 1801418 N/A Replacement No E.M. Jorgensen Trece N-?.302-B Mechanical $nubber Paci6c 333 N/A RSO 2894-87 N/A - No PSA 100 Sdendfic Inenia Mass (she!!) Paci6c Scientific Heat 6061240 N/A Part 1801406 N/A Replacement No Republic Steel Trece N-2419-B inenis Mass (hub) Paci6c Scientific Heat 74976 N/A Pan 1801407 N/A Replacement No Copperweld Trace N-2521-F Torque Carrier (shell) Pacine Scientific Heat A24092 N/A Pan 1801415 N/A Replacement No US Steel Trace N-2403 Torque Carrier (hub) Pacific Scientific Heat A8096785 N/A Part 1801416 N/A Replacement No Republic Steel Trace N-2522-H

 ,s           Telescoping Cylinder          Paci6e Scient 6e    Heat B92372              N/A        Part 1801434           N/A     Replacement       No

/ M.l i US Steel Trace N 1387-C C/ Pmion Gear Pacific Scientific Heat 45638 N/A Pan 1801438 N/A Replacement No E.M. Jorgensen Trece N-2302-B Planetary Gears (3) Pacanc Scienufic Heat 93743 N/A Part 1801419 N/A Replacernent No Copperweld Trace N-1695-D Owner: M}d 9Blt14

                    ,f    G       'V   F ANII: [8 8     /
                                                                                                                                                              .l l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS

4. m.,er.a by as pre,um. .r s. Asus c.a. s h. x:

fm . tf j . Sheet 1 of1 "

 ~V.
1. . Owner: Southess California Edison Company Unit: 2/3 2244 Walent Grove Avemme, a -- A.CA 91770 MO: 88062545 RS: 440 89
2. Plant: San Onofre Nuclear C=.  ; Station P&ID: n/a -

P.O. Bos 128, Sam rs . CA 92674-0128 N-5: n/a 6

3. Work Performed by: Control Components Inc. Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identi6 cation of System: ' m/a Expiretion Date: N/A
5. . (a) Applicable Construction Code: ASME Section III, Class 2,1974 rahaa, S'74 Addenda, Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacemerms: 1977 Edition, S'79 Adda=As
6. Identi6 cation of Components Repaired or Replaced and Replacement Cv- : i Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or '

Code Corrponent Manufacturer Serial No. Board No. IdentiEcation Bulk Replacement Statnped . Yes/No Valve Flug Control Ht.88317 N/A RSO 2940-89 N/A Rspaired No -i Componsens,Inc

7. Description of Work:

j The valve plug wee returned to CCI for design modi 6 cation in accordance with NCR O-949. All welding was performed in accordance with CCI weldhg procedures. Instatistion was perfonned in accordance with FCN $1854J and MO 89040445 and was , documented on a separets NIS-2. ' (

 ./

i NOTE: h MO package which docu====ead the information from the CCI wortsheets was lost. This NIS-2 is bened on the l receiving package, RSO 2940 89, which had undergone a satisfactory receiving inspection by QC and the ANII. '!be -! receiving package contains copies of the CCI worksheets. i 8. Tests Conducted: System Laakage[] System Functional [*] SystemInservice[] Hydrostatic () Pneumatic () Other[]

  • Performed on installation MO 89040445 l

l l l i l 2

                                    .                                                                                                                            l I

O kw Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information in hems 1 through 6 on this nport is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded of this form. and (4) each sheet is initialed and dated by the C;;.,.; or Owner's IMM ; and the AIA.

FORM NIS.2 (back)

9. Rernarks: None.

(Applicable Manufacturer's Data Reports to be anached) CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _ repair. conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp: N/A Certi6cate of Authorization No: N/ Expiration Date: N/A Signed: 8 Owner or 6wner's designee, Tnie

                                                                    .Sur ervisine ASME Codes Enrineer            Datet
                                                                                                                                   /         19h CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Prusure Vene! Inspecton and the State or Province of California, and employed by Arkmicht Mutual InsurBare Comnany (Fsetorv Mutual Eazi a R Association 1 j

Norwood. Mansebu<etts have inspected the components described in this owner's Report during 7 tothe period _ //>/AS 6// (/C f 44 ,and state that to the best of my knowledge and belief, the Owner has performed examindions and taken j correctivsfmeasures dueribed in this owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certi6cate, neither the Inspector nor his employer makes any warranty, expremed or implied, concerning the i examinations and corrective measures described in this Ommer's Report. Furthernere, neither the Inspector nor his employer shall liable in any manner for any penoaalirGury or property damage or a loss of any kind arising from or connected with this inspecti

                                 /2///dI/M1 inspector'sSignature /
  • Commissions M8 Califorr6a 3

(National Board, State, Province, and Endorsements)

                                                               \

Date b*f /[, 19 h

               /                                                                                                                                                 l 1
                                                                                .                                                                                I l

1 1 9

                                                                                                                                                                                          .       t FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS                                                                                                                 ,
4. a.,*.d hr a. m.res A5h5 Cah SammXI shesti erI
,,     1. Owner: Southern California Edison Company                                                                                Unit: 2

[ i 2244 Walnut Grove Avenue MO: 90062403003 \d R--d. California 91770 FCN: F9207M i

2. Plant:

San Onofre Nuclear Generating Station Rspec : 288-90 R2 i San Clemente, Califamia 92674-0128 P&ID: 40123B B-7

3. Work Performed by: - Southern CaliforniaEdison Company N-5: S2-1204-12 Type Code SymbolStamp: N/A Authorization No: N/A  ;
4. IdentiScation of System: Chemical and Volume Control ExpirationDate: N/A  ;

i S. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 A AA=4a (Installation 1 1971 Edition. S*73 ' Addenda (Valvel Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda l

6. IdentiScatiEof Components Repaired or Replaced and Replacement Components:

Reged, ASME Name of Narne Of Manufacturer National Other Year Replaced or Code e- Manufacturer Identification Built R1

                                                                                                                                                                           ^

Seria!No. Board No. stanced YesHe . 1* Diam. Pipe Spool AlTech Heat 01968 N/A 2-SI 139-00A, N/A Repaired No S21204ML139 l' Y-type Globe Kerotest OS23-23 N/A S21204MR040 1976 Replaced Yes  ! Valve l' Y-type Globe Kerotest AEV12-2 N/A RSO 8654-84 1984 Replacement Yes Valve L i

7. Description of Work: 1 The valve was replaced due to valve leakage. ' Since the valve could not be accessed for maintenance due to an I-beam interference, FCN F9207M was generated to relocate the valve to a vertical position to allow adequate access Installation was t performed in accordance with weld records WR2 91-482 Rev. I and WR2-91-485. l l

l

8. Tests Conducted: System Functional Pressure Test Pres: 193.79 nsic Temp: N/A

\.j - um ssi m s. sa 6 w ,h. d - o) a.naanu.ar _

  • i.s w . . s,.,os a d . * *.si.

3)each shest a . f and sw menhar of shese a sus-ded as en og of aus saan, out (4)and shast a sanaled and enand by Ow owner er Ownert dangnes and sa AIA

_ . j FORM NIS-2 (b:ck) ll

9. Remarks : None. i w -.r. r. x,.n . = e l

1

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renair and replacement conforms *
                                                                     ~

to the rules of the ASME Code, Section XI. repairorreplacement T3pe Code SymbolStamp: N/A i Certi6cate ofAuthonzationNo: N/A ExpirationDate: N/A Signed: I/ Sunervisine ASME Codes Enrineer Date: 6!J 7f Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Californis. and employed by Arkwriebt MutualInsurance comoanv (Fsetorv Mutual En eineerine Association) of Norwood. Massachusetts havey*ns3wted the components described in this Owner's Report during the period 9/-3a47/ to 4/M/99 . and state that to the best ofmy knowledge and belief, the Owner has psformed ' examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, spessed or implied, concernmg the examinations and corrective measures desenkd in this Outer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this " 'on. - ME2fSA- Commissions /[ M Californis Inspector's Signature / National Board, State, Prosince, and Endorsements

                                                              \

Date

               /
                   /A$2 NW                                                                                     -

1 1 l l l 1 e I Mo: DCKMG40Kl03 SI I

                                                      ~

a . 1

                                                       ~.

a =... -;.

                                ,.                t            ..
                                                                                                . , .                                                                                                                 :1
                                                               ~
       . ,.     ..                                                                                                                                                            PAGE 1 OF 13     L J

i 4 [e1 *

  • FORM NIS-2 OWNER'SREPORT FOR REPATRS OR REPLACEMENTS
                                                                                                                                                      ~

As aespaired ly the Prowlstens of the ADE Code section XI

  • ys,

- f. E Sheet I of l' -

1. . Oo1mr: - Sedern Califerais Edison Comysey Unit: 2' 2244 Walms Orove Avsame, Reesmead, CA 91770 ~ .Treveler: ' 302-91 032 - I MMp: 2/34&lADSM ;j
2. ' Plant: . Sen Oso6e Nuelser ' , Siedes PalD: 40ll2C l P.O. Bos 128, San Osmesse, CA 9267J.0128 - N 5: 82-1204 I
                                                                                                                                                                                                                      <j
3. Work Performed bys Bashiel (* _
                                                                                                                 ' Compesy                        i Type Code Symbol 5:eey:             N!A -                         '!

P.O. isos 430 Authorization No: N/A Sea Clemmene, CA 92674 0125 Empiration Date: N/A

4. Iden16cedon of Symem: . Safery laqieselee (120d)

(e) 5.. Appliesble Construction Code: ASME Seedom III, Cls u 2,1F14 Edition, S*74 Addende, ASME Semios ll! Claes 2', . 1983 Edidos, 3*SS Addende (Valve) Code Casse: Ne se l (b) . . Applicable Edition of Section XI Utilized for Repairs tr Raphomments: IFTIEdidae, $*79 Addesda

6. . Idend6eation of Components' Repaired or Replaced and Raphseman Components: -

I

                                                                                            -                               .                                                                                              l
                                                                                                                         .                                                                     ASME Repaired.       Code -

Neem of Name of , Manufsemrer Nadonal *

                                                                                                                                                 ~ Oiber.               Year   Repleesd, or   Stamped
      .                               Componess                       Manufseawrer              Serial No.             Board No.               Identi6cedoa .           Bulk   Repleemment    Yes/No hem 25 CWO F plN!!31001
                                          . .                                                                                           DWG # $212NM1A16 M'X .065 WaB Tube                   Sanda Steel Co. HT # SW610
  • N/A RSO # 0879 92 N/A Replacement No g/ . hem 29 ,

CWO # 91N.131001 3/4' Buu Weld , DWG # $212NMIA16 ConeestHm Parker Hannina HTF UAMP N/A RSO f'14'5 91 N/A Raiplacement ' No

  • hem 30 CWO # PIN 1131001 DWG # $212NMIA16 3/4* Tube End Reducer Parker Hennina HT# CAZN N/A RSO F 1469 91 N/A Replacement No hem 31 ,

CWO # 91041131001 DWG # S21204MLD16 M* Tube Union Parker Hanni6a HT# UA01 N/A RSO # 1675-91 N/A Replacement No ~ hem 38 -

  • CWO # PINil31001 DWG # $21204M1A16
                              %* Male Connession                    Parker Hanalna       NT # CSHW                       'N/A           RSO F !$1191                    N/A    Replee-w           No 4                                                               .                                                               ham 34
  • CWO # 91041133001 Andersoa DWG # S21204MI.016 M* Globe Velve Greenerood & Co. S/N N70051 - N/A RSO F144191 1991 Repheement Yes
7. Descripden of work: MMP 2/34697.00$Medding tubing, valve to extend nefety leiection vent line.

Deg.821204M1A16, Weld 'U* performed in eesordance with WR-5.

8. Tems Conducted: CWO 9105031200lVT.2: Hydrostatic IX) Pressure: 2400psis Ternp: 70*F v

r- . . i PAGE 2 OF i3 .- 1 FORM NIS-2 (baek) l

9. Remarks: Documentation for hems listed in Block 6 sre available on site.  :
                                                   'N plirable Manufacturer's Daa Repons to be at:ad.d) l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this relacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol $ tamp: N/A Cer6ficate of Authorizadon No: N/A Expiradon Date: N/A r Signed: [ # Data: 6 C .Ip dah or neerT6esignk, N - - t CERTIFICATE OF INSPECTION I,the sndersigned holding a valid commission issued by the Nadonal Board of Boiler and Pressure Vesse! Inspectors and the State or Province of Cardernia .and employed by . AstwrMe Mutual Insurance company Gecemy Mutual Enrineerine Associadonlof Norweed. Masaechueens have inspectad the components described in this owner's Report during the period .M/EC/94 to MY9//. and state that to the best of my knowledge and belief, the Owner has performed exami6ations 'and'talien corriend measurus described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this card $cate, neither the Inspector not his employer makes any warrancy, expressed or implied, concerning the examinadons and corrective measures described in this Owner's Report. Furthermors, neither tbs Inspector nor his employer shsH, be liable in any manner for any personal indury or property damage or a loss of any kind arising from or connected with this ' inspeedon. b / 7A # d M / />f-' ' Commissions NdM CaEfemie Inspee&s Sigaanarf (National Board, State. Province, and Endorsements ) a /

                             . i
                           .                        O hj

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS as a ed by e %n.mm .f e.asur e.d. sechonu

1. Owner: Southern California Edison Company Unit: 2

/,,) 2244 Walnut Grove Avenue MO: 92040105000,94100193000 () Rosemead California 91770 FCN: F8116M Rspec . I19-94, GEN 139

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128
40112D N-5: S2 1204-4
3. WorkPerformedby: Southern California Edison Company Type Code SpubolStamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section III. Class 1.1971 Edition. S'73 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 F2ition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Nameof Name of Manufacturer Nadonal Other Year Replaced or Code Component Manufacturer Serial No. Board No. Ideraification Buik Replacement Stamped YesNo 8" Tilting Disc Check Anchor / Darling 1N-231 N/A S21204MUO73 1976 --- Yes Valve 5/8"-l1x36" All Nova Machine Heat 6L9541 N/A RSO 1377 93, N/A Replacement No Thread Products SA-453 Gr. 660B 5/8"-lI Heavy Hex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacement No Nuts (8) Products SA-453 Gr. 660B ,O) %)

7. Description of Work:

The hinge pin cover studs and nuts were replaced with an alternate material with greater resistance to stress cotrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT 1 examination was performed on the replacement bolting.

Reference:

FCNF8116M j l i l I

8. Tests Conducted: System Leakare Pressure Test Pres: 648 psia Temp: N/A O

O NOTE. Supplansmal sheet e en farm of hsts, skache, a 6somes awy tw med pnmded (1) sur m 8 IQ m a il m, Q) mfcennban e Itens I trough 6 an $s repan a meluded on each sheet,

3) each sham a menbased and to msnba of shoes is sanneded at ow top of Ous form, and (d)such shed a sutoded and daand by tu Osmar or Owner's designee and Ow AR j

I l

FORM NIS-2 (b:ck)

9. Remarks : None.

w a.mam .wo w . % CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstotherules of the ASME Code, Section XI. repair er reptuement Type Code Syrnbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed:. / / Owner or Oumer's Designee, Title Suoervising ASME Codes Enrineer Date: 7 ' 95 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvince of California. and employed by Arkwricht MutualInsurance Comoany (Factorv Mutua}, - Eneineerine A sociation) of Norwood. Masssehusetts have inspected the components described in this Outer's Repon during the period fl2//f/ M to_ M M A G. T . and state that to the best of my knowledge and belief, the Owner has perfdrme(examinations asitak6n corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from er connected with this ~ spection.

               !       f/J#s@24A_                      Commissions Md:2                            California Inspector's Signatur/                                       National Board, State, Province, and Endorsements Date b uO. 9.$$ 9 5 MO: 920aD106000
         .,                   w,,              . .,                                             -            ..            ..            ..        .-                                  - ,                      , ~ .   .
       );
                   . - lfu<

PORM NIS-2 OWNER'S REPORT POR REPAIRS OR REPLAN 8WIS j unoms are e=as== se e mas c=* s=m== m  ; f.i; , q

                                                                                                                                             ' Sheet 1 of 2                                                                  ,
1. Owner: Southern QNorula Edson Conapany . Unit: - 121
                                                      - 2344WalnutGrove Anasse,W CA 91770                                                      MO:        ~ 93061092                                                      ;;

RS: 07343 Rev.1 .;

2. ' . Plant: See Ono6e Medaar Gensuales Station P&ID: 40124B l
                                                      . PD. Bos las, see Gamann, CA 93674 4128                                              , N-5:          53-1208                                                                                                                                                                                                                               .
                                                                                                                                                                                                                           's
3. Work Performed by: seuduen CaWornia Edison r a r-y Type Code Symbol Stamp: N/A  !

Authorisation No: N/A  ;

4. .- Identiikation of System: th=3=I and Volumme Control . Expiration Date: -N/A 5.' (a) . ' Applicable Construction Code: ASME Section IR, Ones 2,1974 E6 tion, F75 Addenda, code Camas: None j e

(b) Applicable Edition of Secuon XI Utilized for Repairs or R-T-------.ts: 1989 Edition, No Addenda

                                                                                                                                                                                                                          .l
6. Identification of Components Repaired or Replaced and PT- ;- - t e mts: l Repaired, ASME  ;

Name of . Name of Manufacturer National Other. Year Replaced, or - Code * , Component Manufacturer Serial No. Board No. Mentification Built Replacement Stamped l Yes/No Suction Stabilizer Greer Hydraulics GHI-2987. 240 521208MW247 1978 ... Yes.  ! inc. End Plate ABB e - _ _ ; _-- SN 3140-3 N/A R'iO 3329-93 N/A Reptar* mat . No ; . l Pj 15 Hr.3A837 Part 404528 ~! 71uended Ring ABBE '_. - SN 3140-7 N/A R50 3329 N/A -, t. No

                                                                  'j- .i Ht.33366                                                  Part 404529                                                             .

Valve Stem ABB r - ' ' N/A N/A RSO 0745-94 N/A P*Pl an= = 9t No

                                                                                                                                                                                                              ~

Engineering Part 408524 > Adapter ABBE - - N/A N/A R50 0745-94 N/A -, - - - - No .i Engineering Part 552775 i Union Nut ABB r - ' "= N/A - N/A R50 0745-94 N/A T, t No Engineering Part 552774  : Bag Stem Adapter ABBR - N/A N/A R50 0745-94 N/A Pertarwment No Engincanns Part 552773 Nut ABB r - - N/A.. N/A. R50 0745-94 N/A , ---

                                                                                                                                                                                                       .No F-j         '.4
                                                                              .                                                    Part 408325 Sintered Tube Assembly                  ABBE                 '=   N/A                         N/A          RSO 0745-94               N/A        " ,-       - -

No Engineering Part $52776

7. Description of Work:

1he sucnon stabiliser was rebuilt in accordance with NCR 92060024.1he Code parts listed above required . . * - t. MO- , 92061092001 performed the ram-=bly and MO 92061092002 performed the instaBadon.

8. Tests Conducted: System Isakage [ } System Funcuonal [X] System Innervice [ ] Hydrostatic [ ] Pneumatic [ ] Other [ ]

Pressure: 22.4 psig Temp: N/A Note: Supplemental sheets in the form of lists, sketches, or drawings inay be used primded (1) size is 8 % in. x 11 in, (2) Information ' in Items 1 through 6 on this suport is included on each sheet, (3) each sheet is numbered and the number of sheets is . secorded at the top of this fann and (4) each sheet is inidaled and dated by the Owner or Owner sa desinnee and the AIA. r , ,w.4  %- -- -r - s w - - . - e ,-, , .- _- - _ - e - < - - - -

                      ~

e W2.1 NIS-2 (back)

9. Remarks: None ,

4 (Applicable Manufacturers Data Reports to be attached) CERIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this renlacement Section XI. e Code, conforms to I Type Code Symbol Stamp: N/A 1 Certificate of Authorization No: N/A Expiration Date: N/A l Signed:

                             /h Owner or(C.a.a's Designee, 71rje
                                                           .Simervisine AS   Codes Enrineer         Date:           /I        19 l

i CERIFICATE OFINSPECUC?! l i I, the undersigned holding a valid commission issued by the Nationaln Board of Boiler an or Province Norwood. of _Califgab Massachusetts havejpspectcQeand employed by Artwrirbt MutualInsurance Company t e tate (Factor 5/PS/M to _ & / Z / 7 mponents described in this Ownefs Report during the period

                                                      . and state that to the best of my knowledge and belief, the Owner has performed exarninations and taken corrective measures descnM in this Owners the ASME Code, Section XI.             *
o. Report By signing this certificate, neither the Inspector nor his employer makes ,

any warranty, expre erning the examinations and corrective measures described in this Owners Report. be sa Furthermo ins; e in any manner for any\\personal Irgury or property damage or a loss of any kind arisin

           'on.

i

                                  }                                                                                                         '

1 Irspiors Signature Comminions _ cA f 5T4 CaHfornia (Nationa) Board, State, Province, and Endorsements ) DateMM 19 Ud I 1 l i

                                                                                                                                       ^

9 l l j

                                                                                                                                                              '~

3 o . .. . . . . , , . . . . . a. . .. , .: . .. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMEN13  !

                                                                     , as paraised by as Pmbisms'ef de Asas rade Sandse M                                                     [

J ., b,[ k 1. Owner: . Southern California FJison Company Sheet 1 of1 Unit: 2/3

    .                                     2244 Walnut Getwe Avenue, PM, CA 91770                                          MO:         92072166
                                             ..                                                                        ' RS:          182 92, Rev. I                           '
2. Plant: San Onofru Nudear Generadng Station PacID: 40179A 01-S)

P.O. Box 128, San Gesmente, CA 92674-0128 N S: SA-1513 5  ; 3 Work Performed by: Southern California fem Company ' Type Code Symbol Stamp: N/A j

                                                                                                                                                                              ~

Authorization No: N/A

4. Identificadon of System: Onilled Water Expiration Date: N/A j S. (a) Applicable Construction Code: ASME Secuan III, Cass 2,1971 Edition, S73 W= (Valve),

1974 Editioit S74 Mdenda (Piping) Code Cases: None , (b) Applicable Edidon of Section XI Udlized for Repairs or Replacements: 1977 Edition, S79 Addenda

6. Idendficadon of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Namc. of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identificadon Bullt Replacement Stamped Yes/No w" Globe Valve Kerotest AAE10-7 N/A SA1513MU393 1979 Replaced Yes r

                      %" Globe Valve                  Kerotest       AUQ1-25                     N/A          RSO 3013-91             1991    Replacement        Yes
                      %"$ Pipe Nipple                 Quanex         Ht.82995                    N/A          RSO 0177-93             N/A     Replacement        No.

Sch 80 SA-106, Gr. B t, d

   ,!     /,         7.        Descripdon of Work:
  ~

The %* globe valve in plant position SA1513MU393 and the downstream pipe nipple were replaced (ref. WR2/3-92 458).

  .                            MT examinadons of the replacement welds were performed.

t

8. Tests Conducted: System Izakage [ ] System Functional [X] System 1nservice [ ] Hydrostatic [ ] Pneumade [ ] Other [ ]

Pressure: 38 psig Temp: N/A

  • i 4

f

   >                                                                                                                                                                          t
  &V                 Note:     Supplemental sheets in the fonn of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in, (2) j k                            information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of j                            sheets is reconied at the top of this form.

G t 1 i  :,

.- FORM NIS-2 (back) .

9. Remarks: None -

(Applicable Manufacturers Data Reports to be attached) l l 4 CER~nFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and :his replacement confonns to the rules of the ASME Code,' Seedon XI. Type Code Symbol Stampi N/A Certificate of Authorizadon No: N/A Expiradon Date: N/A Signed: . I/ # .Supervisinr ASME Codes Enrineer Date- 2 .19 Owner or Owneff Designee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission Issued by the National Board of Boller and Pressun: Vesselinspectors and the State or Province of California and employed by Arkwright MutualInsurance Company fFacrory Mutual Edmi.i Assodadon) of ectep Jhe com Norwood. W/#/4 Me- er J.astohave,insp/H/ A2,/ 94/- ponents

                                                                        . and statedescribed     in of that to the best this myOwners knowledgeReport     during and belief,       the period the Owner has perf6rmed examinadons and then correcdve measures desenhd in this Owners Report in accordance with the requirements of

. the ASME Code, Secdon XI. By signing this certificate, neither the Inspector nor his employer makes any, warranty, expressed or implied, concerning the examinadons and corrective measures desenhd in this Owners Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspeedon. [ ###bMm # Commissions ///IS California (Nadonal Board, State, Province, and Endorurnents ) Inspectors Signature

     .            Date           I                ,  19 h M h\

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. n a.4 by m. pna- <m. asia cod. s 6.xx ,

shast i et 3 s, ' l. Owner: Southern CaliforniaEdison Company Unit: 2

 /

b] 2244 Walnut Grove Avenue Rw A. California 91770 MO: 92090930000 Rspec- 037 93 R1 P&lD: 40112A

2. Plant: San Onofre Nuclear Generating Station N-5 '- S2-1204 34 San Clemente, Califamia 92674-0128
3. WorkPerformedby: Southem CaliforniaEdison Company Type Code Symbol Stamp: N/A Authanzation No: N/A
                                                                                                        *         *               ^
4. Identification of System: Safetyinjection and Shutdown Cooling
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition. S'73 Adhda Code Cases None

- (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repand ASME Name of NameOf Manufacturst National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identificahon Buik Replacement Stamped Yes/No . 4" Stop-Check Globe Anchor Darling 2N-773 N/A S21204MUO15 1977 - Yes Valve ' Disc Anchor Darling Heat 30415 N/A RSO 1157-91, 1991 Replacement Yes SA-479 Tp 316 w/ Stellite b d i

7. Description of Work:

The valve dise was replaced nAer boric acid c ystals were observed on the packing gland and valve stroking had become difficult. ' l i 1

                                                  ~

I l 4

8. Tests Conducted: System Functional Pressure Test Pressure: 1485 usic Temp: H!/A
        - .-. . sunbered                                                                                  .a- - .           -. - . -

3)each sheet and su member of shoem . sesordsd at tw top of aus fana, and (4)see shout is amenled and deemd by de Owner er ow

FORM NIS-2 (b:ck)

9. Remarks: None.

w ru. a,.n, a _ c,, CERTIFICATE OF COMPLIANCE We certify that the statements taade in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. . repair orreplacement T3pe Code Symbol S'. amp: N/A Certif2cate ofAuthanzation No: N/A Expiration Date. N/A I Siped: M Supervisine ASME codes Encineer Date: 6/2 SS Owner or dwaer's Desipec, Title ' CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orPrmince of California. and employed by Arkwrfcht Mutual Insurance Comoanv (Factorv Mutual Eneineerior Associationiof Norwood. Massschusetts have iW' ~4 he tcomponents described in this Owner's Report during the period S&B/Ft./- to #>/JU/94~ . and state that to the best ofmy knowledge and belief, the Owner has pe'rformed examinations and 14 ken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, agd or implied, concerning the examinations and conective measures described in this Owners Report. Furthermere, neither the Inspector nor his empicycr shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connectedwith ' inspection.

                  . hhAC//A/                         Commissions       /[dA                        Califomia Isspectors Sipat6re                                        National Board, State, Province, and Endorsements              '
y. -
                                                           \

Date Ad A7, lW

                                                                                                                                       \

i l I i i l 1 i i I l l Mo: e20eoricooo  ;

                                                                                              .W
  .                                                                                       .:      :,--~.              .-........s.             . ... .           .           .                         ' ~ ~ ~ ~v FORM NIS-2 OWNER'S REPORT FOR REPMRS OR REPLACEMENTS uwwen                 .a masna ca se m Sheet 1 of1
~
1. Owner: Southern California Ed'non Company Unit: 2 2244 Walnut Grtw Avenue, Rosemead, CA 91770 MO: 92091550 RS: 243-92
2. Plant: San Onofre Nudear Genaating Station P8dD: 40123B P.O. Box 128, San Gemente, CA 92674-0128 N.S: S2-1208 11
3. Work Performed by: Southern California M- Company Type Code Symbol Stamp: N/A Authorizadon No: N/A
4. Identificadon of System: Quenucal and Volume Contral Expiradon Date: N/A S. (a) Applicable Construction Code: ASME Secdon III, Class 2,1974 Edition, S76 Addenda, Code Cases: None (b) \ Applicable Edidon of Secdon XI Udlized fer Repairs or Replacements: 1977 Edition, S79 Addenda
6. Idendficadon of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer Nadonal other Year Replaced, or

  • Code Component Manufacturer Serial No. Board No. Identificadon Built Replacement Stamped Yes/No 3" Control Valve Copes-Vulcan 7620-95400-29-5 1449 2FV0203 1977 ... Ycs Valve Flug Copes-Vulcan 9321 96397 1 1 N/A RSO 1893-93, Rev.1 N/A Replacement No SAS64, Gr. 630 l
7. Descripdon of Work:
                                                   'Ihe valve was daassembled and the valve plug replaced.

(Q'! 1

8. Tests Conducted: System Izakage [ ] System Funcdonal [X) System Inservice [ ],Hydrostade [ ] Pneumade [ ] Other [ ]

Pressure: 320 ps'g Temp: N/A . Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) s 2e is 8 % in. x 11 in., (2) Informadon 2 in Items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this forTn, and (4) each sheet is initialed and dated by the owner or Owner's designee and the AIA.

FORM NIS-2 (back) 9 Remarts: None O (Applicable Manufacturefs Data Reports to be attached) CERTIFJCATE OF COMPilANCE We certify that the statements made in the report are correct and this rC-a,t conforms to the rules of the ASME Code, Seedon M. Type Code Symbol Stamp: N/A Certificate of Authoriz.adon No: N/A Expiration Date: N/A Signed: /[ .Sumvisinr ASME Codes Enrineer Date: .19h

 ,                 Owner or Owne/s Designee,Ilde CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of BoDer and Pressurt Vessellnspectors and the State or Province of Califomia and employed by Artwriebt Mutual losurance Comneny (Facttwv Mutual Enrincerior Assodation) of the com Norwood.
          /;9/C//4/   M.--de A have to /0hinspecte(#Al
                                            -7/           ponents    described in this owners Report during the period
                                                            . and state that to the best of my knowledge and belief, the Owner has perfor6ed dxaminadons and'tlken correedve measures desenhd in this owners Report in accordance with the requirements of the ASME Code, Secdon M.

By signing this certiScate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the I examinadons and correctin measures described in this owners Report. Furthermore, neither the Inspector nor his employer shan be liable in any manner for any personal Irdury or property damage or a loss of any kind arising from or connected with this inspeedon.

                                 /M?M2f
  • Commissions / 2. Califomia inspectorTSFgna'ture ' / { National Board, State, Province, and Endorsements )

Date /AN/ $, 19 ~ Y ' l u .. I h

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS < A.nW Wto Pnmaau oftw ASME CMM asmien 6

1. Owner: Southem Califomia Edison Company Unit: 2 l g) .

,t 2244 Walnut Grove Avenue MO: 92101023002 93060988000  ; b/ Rosemead,Califomia 91770 Rspee. 229-92  ! P&ID: 40124B C-2 >

2. Plant: San Onofre Nuclear Generating Station I N-5: S2-1208-5 San Clemente, Califomia 92674-0128 l
3. WorkPerformedby: Southem Califomia Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A ExpirationDate: N/A I
4. _ Identification of System: Chemical and Volume Control  ;
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1971 Edition. S'73 Addenda. Code Cases: None f (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda j i
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared. ASME Name of Nameof Manufacturer National Other Year Replaced or Code - Component Manufacturer Seria1 No. Board No. Ident fication Built Replacement Stamped t Yes% ' 2" Y-type Globe Kerotest MC8-7 N/A S21208MU018 1976 - Yes Valve  ; Bonnet Kerotest Ht Code DAS N/A RSO 5736-84, N/A Replacement No SA-479 Tp 316 i

  /                                                                                                                                                                                                  I
7. Description of Work: l Leakage was observed from the valve while perfonning maintenance on another component. The bonnet required j I

replacement. The replacement bonnet was cannibalized from a new valve (SN AFH4-17). SCE perfonned a ten-minute hydro on the new valve prior to removing the bonnet. s

8. Tests Conducted: System Functional Pressure Test Pressure: 2350 nsin Temp: N/A 1

.(  ! l

        - .                _ . -., _ ..w                                   r - m_ .. ... mz                                          m .s   . ._e, . _ _ _

3)each shes e ownband and de nianha of shese s recorded et On top of Gus fem and (s) each shest e inmaled and esend h tw owner er Owners desyse and em AIA, l 1

                                                                                                                      . - - -                 .                           _                .--   .l

FORM NIS-2 (b:ck)

9. Remarks : None.

v - w, u. m a . a-a> CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reniscement codormstotherules of the ASME Code, Section XL npair or nptuemar Type Code Symbol Stamp: N/A Certificate ofAuthonzation No: N/A Expiration Date: N/A Signed:_N/ Sunervisine ASME Codes Encineer Date: &/k/35 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors a the State or Province of California, and employed by A rkwricht Mutual Insura nee Comnanv (Factorv Mutual -- - Encineerine A esoelation) of Norwood. Massachusetts b4ve inspected the components described in this Oume

                                                                                                                                  -    ~

during the period 6/3 /'43 to / 8/ 4 MS . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, con examinations and corrective measures desciibed in this Owner's Report. Furthermore, neither the Inspector nor his empl5yer shall be liable irphy manner for any personal injury or property damage or a loss of any kind arising from or cornected wi tion. th>t c Inspector's Signature b Commissions 1574 california illI h National Board, State, Province, and Endorsements Date b/b/36 W: 921010230c2

i 1

                                                  ' FORM NIS-2 OWNER'S REPORT FOR REPMRS OR REPIACEMEN13
4. n.,4 or s. n % .t a. ama ca s i m l
 -(                                                                                                                                                                            l 5                                               .

Sheet 1 of 1 1'

           ,e-
1. Owner: Southern California Edisoo Company Unit: 2 2244 Walnut Giove Avenue, PM, CA 91770 MO: 92101793 i RS: GEN 428 Rev 0
2. Plant: San Onofre Nuclear C-.4 Stadon P&.!D: 40112C (H-7)

P.O. Box 128, Sanr %= ente, CA 92674 0128 N-5: S2-1204-34 ,

3. Work Performed by: Southern California Edison Company Type Code Sy1nbol Stamp: N/A l Authorizadon No: N/A .f
4. Identification of System: Safety lajecnon Expiradon Date: N/A S. (a)' Applicable Construedon Code: ASME Secuon III, Class 2,1974 Edition, S74 Ald-tm, Code Cases: None j

(b) Applicable Edidon of Secdon XI Udlized for Repairs or Replacements: 1977 Edition S79 Addela

6. Identifi~c ation of Components Repaired or Replaced and Replacement Components:
                                   ,                                               ,                                                        Repaired,        ASME Name of                   Name of           Manufacturer        Nadonal               Other          Year    Replaced, or      Code-Component               ~ Manufacturer         Serial No.       Board No.         Identificadon       Built   Replacement      Stamped Yes/No
                 +
                      !" Nozzle 7)pe                     Crosby         NS9370-00-0003          N/A        2PSV9320-               1978        --              Yes Relief Valve                                                                         JR-WR S-SPL Valve Duc                           Crosby         N91250-37 0022          N/A        RSO 1379-92             N/A     Replacement         No           j i

Valve Spring Crosby NX2659-0011 N/A RSO 0548-92 N/A R$~-t No A313, Tp 316

         ~

Spring Washers (2) Crosby N91252-36-0018 N/A RSO 0548-92 N/A Replacement No

      %                             .                                   N91252-36-0019                     Stellite 6B Spindie                            Crosby         N912SI-35-0013          N/A        RSO 1251-92             N/A     Replacement         No Stellite 68
7. Descripdon of Work: .

i Relief valve was removed from plant locadon 2PSV9320 and was bench tested. De bench test failed and the valve was rebuilt, retested (passed) and reinstalled. l l l

8. Tests Conducted: System leakage [ ] System Functional [X] System Inservice ( ) Hydrostade [ ] Pneumatic [ ] Other [ ]
                                'ressure: 1350 psig Temp: N/A i

l l k

    =
    .- ?%..

Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 5 % in. x 11 in., (2)Information in hems I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the inn of this form. 1

FORM NIS-2 (b:ck) P. Remarks: None (Applicable Manufacturers Data Reporu to be attached) l CERTIFICATE OF CdMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,

 ,       Section XI.

Type Code Symbol Stamp: N/A Certificate of A thorizadon No:' N/A Expiradon Date: N/A . Signe aAr . 2A/Y .Supenising ASME Codes Endneer Date: M. / 19 M Owner or vs Desigg Tide CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pr.ature vessel Inspectors and the State or Province of Califomia. and employed by Arkwritht Mutual Insurance Company (Factory Mursal Enrincerinz Amdation) of eet e mponents described in this Owners Report during the period Norwond. SN/ MManachusetts to , d/ have insg/

                                                     /         . and state that to the best of my knowledge and dief, the Owner has perfo'rmed examinadons and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Secdon XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implief, concerning the examinations and corrective measures described in this owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspeedon.

                     - , /VM,*M1

_ Commissions /[NN California inspector's signature (Nadonal Board, State, Province, and Endorsements ) 8

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS u w w .c .c a.ma c.a. s m n i l L ,/ . Sheet 1 of 1

1. Owner: . Southan California Edisco Company Unit: 2 2244 Walnut Grwe Avenue, Ph. CA 91770 MO: 92110881 RS: GEN-012, Rev.1
2. Plant: San Onofre Nudear C_.Gog Stadoo P&ID: 40124B 01,2)

PD. Box 128, San Ocmentr, CA 92674-0128 N-S: S2-120lLS

3. Work Performed by: Southern California r h Company Type Code Spnbol Stamp: N/A Authorizadon No: N/A
4. Idendficadon of System: Chenucal and Volume Control Expiration Date: N/A S. (a) Applicable Construcdon Code: ASME Secnon ID, Class 2,1974 Edition, S74 Addenda, Code Cases: None (b) Applicable Edidon of Section XI Udlized for Repairs or Replacements: 1977 Edidon, S*79 Addeda
6. Idendficadon of Compsnents Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer Nadonal Other , Year Replaced, or Code Component Manufacturer Serial No. Board No. Identificadon Built Replacement Stamped Yes/No 1%" x 2" Relief Valve Crosby N5938040-0010 N/A 2PSV9225 1985 -- Yes Disc Crosby N91241-44-006S N/A RSO 2505-92 N/A Replacement No Stellite 6B Spring Crosby NX3055-3482 N/A RSO 2202-85 N/A Replacement No A313, 'I). 316 6 Spring Washers (2) Crosby N90982-54 0467 N/A RSO 2202-85 N/A Replacement No

 ',                                                                               N90982-S4-0469                    Stellite 6D
                                                                                                                                                                       ~

i> i Nozzle Crosby N91243-39-0035 N/A RSO 045192 N/A Replacement No SA-479, Tp. 316L

7. Description of Work:

The relief valve in plant posidon 2PSV9225 was disassmbled to determine the cause of the leakage. The valve was

               .                             re-assembled using the replacement parts listed airwe.
8. **[e Ccmducted: System Leakage [ ] System Tunctional (X) System Inservice [ ] liydrostade made'.1 [] Other []

Pressure: 2310 psig Temp: N/A J I j [ 4

               )                                                                                                                                                                                 1
 ;                    Note:                 Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information in Iterns 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

m FORM.a.r2 (back)

9. Remarks: None (Applicable Manufacturers Data Rev eits to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reptammet conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stampt N/A Certificate of Authorizadon No: N/A Exptradon Date: N/A

                                                         .Sutervisine ASME Codes Enrineer            Date:     /            .19M Signed:                                                                                                     '

Ciwner otDwners Designee, Title CERTIFICATE OF INSPECTION . I, the undersigned holding a valid cohunission issued by the National Board cf Boiler and Pressure vesselinspectors and the State or Province of California. and employed by Ad *ar Mutua1 Insurance Comonov (Factory Mutual Fa% Assndation) of Norwood. Massachusetts have inspected the con.ponents descnkd in this Owners Report during the period

         % - X> // -%Yto / 9t/ . and state that to the best of my knowledge and belief, the owner has performed examinadons and taken correedve measures described in this owner's R,eport in accordance with the requirement the ASME Code, Seedon XI.
  • By signing th'is certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningithe examinadons and correedve measures described in this owners Report. Furthennore, neither the Inspector nor his employer sha!! j g be liable in any manner for any penonal injury or property damage or a loss of any kind arising from or connected with this inspeedon. ,i
                          /OWMdar#T                           Commissions /8[ N                             California Inspeftd/s Signatur/                                           (National Board, State, Province, and Endorsements )         f l

17 , 'i- 19h Date , e.--~. . . I l i

4

, f
                                                                                                                                                           ~I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMEN13 a.ama p m..tesesc.a.s a a                                                      ,

N. Jg% > 3 wi

          /                                                                                                   Sheet 1 of 1
 ' 'ff            1.          Owner: Soutbern CnWornia FAimaa twap==y 2344 Walnut Grove Avenue, PM, CA 91770 Unit:        2                                 [

MO: 93013671

                                                                          .                                   RS:          074-95
                ' 2.          Plant:     San Onofre Nucleare -. '. ; Stados                                   P&ID:        40112A (G-3)

P.O. Box 128, San r L==> CA 92674 4128 N-S: S2 1204-34

3. Work Performed by: Southan CaEfornia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identificadon of System: Safety injamaa Expiradon Date: N/A
  • S. (a) Applicable Construcdon Code: ASME Genaa IE, C3am 2,1971 Edition,573 Add =da, Cbde Canes: None i

(b) Applicable Edidon of Section XI Udlized for Repairs or Replacements: 1977 Edicon, S79 Addade i

6. - Identificadon of Components Repaired or Replaced and Replacement Components:

Repaital. ASME Name of Name of Manufacturer Nadonal Other Year Replaced, or Code Component Manufacturer Serial No. Board No. {

                                                                                                      .Identificadon       Built  Replacement     Stamped    e Yer/No     I
                  %" Y-Type Globe Valve             Kerotest      VH12-2                  N/A       S21204MR352            1978         -.           Yes Bonnet                           Kerotest     JSY13-1                  N/A       RSO 1798-93            1993   PT-t               Yes     i SA-479, Tp 316                                           1
7. Description of Work:
  /7 I

The valve was disassembled to detennine the cause of the rough operadon. The valve bonner was replaced and the valve was reassembled. g:

8. Tests Conducted: System leakage [ ] System Tunctional [X) System Insemce [ ] Hydrostade [ ] Pneumatic [ ] Other [ ] '  :

Pressure: 1140 psig Temp: N/A I

  \
    ?d%

Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in, (2) information in 1: ems 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 (back) . 9, Remarks: The replacement bonnet was cerdfied to ASME III, Class 1. (Applicable Manufacturefs Data Reports to be attached) CERTIFICATE OF COMPLIANCE - We cerdfy that the statements made in the report are correct and this iuA.wr4 conforms to the rules of the ASME Code, Seedon XI.

           'Iype Code Symbol Stamp: N/A Certificate of Authorizadon No: N/A            -

Expiradon Date: N/A Signed: MA .Supervistne ASME Codes Enrineer Date: N*N .198

   -                   Owner or Ow' nets Designee, Tide CERTIFICATE OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vesse'.I Inspectors and the State or Province of California and employed by Arkwriebt Mutua11osurana Company (Factory Mutual Engineerine Assodation) of Norwood. MM is have inspectedjhe components desenM in this Ownefs Report during the period
              .#/#7/9A                to 4//6~/98 . and state that to the best of my knowledge and belief, the Owner has perf6rmed Examinadons and taken cferective measures desenM in this Ownefs Report in accordance with the requirements of the ASME Code, Seedon XI.                                                                                                             g-By signing this certificate, neither the Inspector nor his employer makes any' warranty, expressed or implied, concerning the     i examinadons and corrective measures described in this Ownefs Report. Furthermore, neither the Inspector nor his employer shall        v be IIable in any manner for any personal injury or prcperty damage or a loss of any kind arising from or connected with this inspection.
                                        &*od/M                           Commissions      /Idj                       Califomia Inspectors' Signature #                                         , (Nadonal Board, State, Province, and Endorsements )         ,

Date / I 19 k N ' N O

                                                                                                                                                                   ]

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As ll:4used 17 Gw herwers ef 9w ASME Code 5ccweN,

                      '                                                                                         Sheet i ofi
1. Owner: Southem Califomia Edison Company Unit: A
 .~N 2244 Walnut Grove Avenue                                                                MO:

(j Rosemead,Califomia 91770 93040963000 Rspec: GEN-112, RI

2. Plant: San Onofre Nuclear Generating Station P&ID: N/A San Clemente, Califomia 92674-0128 N-5 '- N/A
3. Work Performed by: Southem Cahfornia Edison Company Type Code SpnbolStamp: N/A Authorization No: N/A
4. IdentificationofSystem: N/A Spare Expiration Date: N/A

, S. (a) Applicab'.e Construction Code: ASME Section III. Class 2.1974 Edition. S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

NameV Repaired. ASME Name Of Manufacturer National Other Component Year Reptaced er Code Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 1 1/2* x 2* Nozzle Crosby N59380-00-0006 N/A 025-83508 Spare 1978 --- Yes Type Relief Valve DiseInsert Crosby N91241-47-0082 N/A RSO 1125-93 N/A Replacement No Stellite 6B

7. DescriptionofWork:

[N The valve was removed from position 2PSV9227 on MO 92080825 and was reworked under the rebuild program. The disc was replaced and the valve was reassembled, tested and returned to warehouse stock.

8. Tests Conducted :ES Pres:N_!% Temp:El%

_s

3) and ahee e awad and ou mesnbar of shoes _.._.,,s a sweeed _ ._,._..
a. tw top of _om larn6 and _(4) and aheet s' estidad an

V FORM NIS-2 (b:ck)

9. Remarks : None.

m umm m m mt,.as O CERTIFICATE OF COMPLIANCE We eenify that the statements made in the repon are correct and this renlacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: MM M Owner or Own'er's Desicnee, Title Sunervisine ASME Codes Encineer Date: 9 !96 CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkw rirht Mutual Insurance Comoanv (Factorv Mutual Enrineerine A siociation) of Norn ood, Massachusetts have inspected the components described in this Owner's Report during the period 6 //3/'/4 to 3/2//95 , and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X]. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this

        /           ,1 h g[

ucM  % -JLo Commissions Califomia f574 Inspector's Signature National Board, State, Province, and Endorsements Date 4/3/95 . . _ O

n FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS un d era = pr - -.re.4xha cois s 6.nxi

   .-         1. Owner: Southem California Edison Company                                                     Unit: 2
 /    i                        2244 Walnut Grove Avenue                                                       MO:        93051202000,94100193000 V                             Rosemead, California 91770 FCN: F9656M Rspec : 116-94, GEN-139
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40112C D-3 N-5: S2-1204-5
3. WorkPerformedby: Southern Califamia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Reactor Coolant Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 1.1971 Edition. S*73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared, ASME Name of Name Of Manufacturer National Other Year Replaced or Code Component Manufactuur Serial No. Board No. Identification Built Replacement Stamped - YeWNo 3* Tilting Disc Check Anchor / Darling IN-218 N/A S21204MU018 1977 - Yes Valve 1/2* 13x36" All Nova Machine Heat 16925 N/A RSO 3299-93, N/A Replacement No nread Products SA 453 660B 1/2*-13 Heavy Hex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacement No Nuts Products SA-453 660B

7. Description of Work:

The hinge pin cover studs and nuts were replaced with an attemate material with greater reststance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCNF9656M l

8. Tests Conducted: System Functional Pressure Test Pres: 647 t, sic Temp: N/A v) N0rt-
  • 4 _.cJ slwen m en farm of bst, sketches, or dresmgs may be med psovuled (1)aus u 810 m a il m, Q) sdannonan m hans a through 6 on aus report a su:luded an sash sheet, h each shast a susnbensi and en number of sheets a sneerded at tw top of thes ions and (4)each sheet a subated und dead by to ommer er Owners darqmee and the AR

FORM NIS-2 (b:ck)

9. Remarks : None.

wn m,sw n.m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conformstotherules of the ASME Code, Section XI. mirww Type Code Symbol Stam;i: N/A Certificate ofAuthorizationNo: N/A Expiration Date: N/A Signed: , MSunervisine ASME codes Encineer Date: /M' Owcer or Owner's Designee, Title L CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rimicht MutualInsurance Comcanv (Factorv Mutual - - Eneineerine during the period Aesoefstion)p/4/G4f fj/ toNorwood. _A/G/Q5 Massschu setts have insp~ected the components described

                                                                                  . and state that to the best ofmy knowledge and belief, the Owner has perfonne'd examinations and tfien'conective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this in9ection.

                  !            ~

Inspector's Signsture / MM Commissions /I N Califomia National Board, State, Province, and Endorsements Date AB, Q. /@8

                    /~

Mo: 93051202000 Wi i l 1

                                                                            ~

1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A. me,*ed by s. was ofk ASME Coe hW , 1. Owner:. SouthemCalifomiaEdisonCompany Unit: 2 () N._ / 2244 Walnut Grove Avenue Rosemead,Califomia 91770 MO: 93051203000,94100193000 FCN: FM57M Rspec : 117-94, GEN 139

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 PalD: 40112C C-3 N-5: S2-1204-4
3. WorkPerfonnedby: Southern California Edison Company Type Code SpnbolStamp: N/A AuthorizationNo: N/A'
4. IdentificationofSystem: ReactorCoolant Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 1.1971 Edition. S'73 AMmda Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared, ASME Name of Name Of Manufacturer National Oiher Year Replaced or Code Componera Manufacturer Serial No. Board No. Ihm~4 Built Replacemerd Stamped . Yes/No 3* Tilting Disc Check Anchor / Darling 1N-205 ' N/A S21204MU019 1976 - Yes Valve "2"-13x36" All Nova Machine Heat 16925 N/A RSO 3299-93, N/A Replacement No 3 read Products SA-453 660B 1/IM Heavy Hex Nova Machine Heat 24848 N/A RSO l377-93, N/A Replacement No Nuts Products SA-453 660B O

7. Description of Work: >

The hinge pin cover studs and nuts were replaced with an alternate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT-1 examination was perfonned on the replacement bolting.

Reference:

FCNFMS7M

8. Tests Conducted: System Functional Pressure Test Pres: 648 psig Temp: N//A J
     - -- . - 3)och
              . amber        elsheen ehest a nunbered and eu
                                                               .~n
                                          ' sesordedsat the 69 of Sus form,. .and     to n (4) nsm eache shoes e aumeled
                                                                                                                 . eb.. and-- --a.h dee.d by Ow .swner er Owne

FORM NIS-2 (b:ck)

9. Remarks : None.

e; x - = % .. . - CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reviseement corformstotherules of the ASME Code, Section XI. repair er reptacemar. Type Code SymbolStamp: N/A Certificate of AuthorizationNo: N/A Expiration Date: N/A Siped: M Supervisine ASME CodesEnginar Date: S!8 f Owner or Owner's Desipee, Title CERTIFICA~E OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vesse! Inspectors and --= the State or Province of California. and employed by .Arkwricht MutualInsurance Comnanv (Factorv Mutual - EnrIneerine Association)9f Norwood. Mass achusetts hpe inspected the components described in this Owner's Report during the period /S//A/G46 to /7/G/C6 . and state that to the best of my knowledge and belief, the Owner has performe'd examinations and4aker/cdrective measures described in this Owner's Report in i accordance with the requirements of the ASME Code, Section XI. J By siping this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in this Owr er's Report. Furthermore, neither the Inspector nor his  ! employer shall be liabic in any manner for any personal inymy or property damage or a loss of any kind arising from or 4 connected with this in tion. Af/22/ht Commissions /Id California i National Board, State, Province, and Endorsements

                                       ~

Inspector's Sipature / i 1 l Date 4pf. 9. $$9T

r i.. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.a m s h .csi,Asusca.s m

1. Owner: Southern Califamia Edison Company Unit: 2
   /O                       2244 Walnut Grove Avenue                                                    MO:     93051204000,94100193000
   -V                       Rosemead,Califamia 91770 FCN: FM59M Rspec : 118-94, GEN 139
2. Plant: San Onofre Nuclear Generating Station San Cicmente, California 92674-0128 P&ID: 40112C N 5: S2-1204 2
3. WorkPerformedby: Southern Califomia Edison Company Type Code SymbolStamp: N/A Authorization No: N/A l
4. Identification of System: Reactor Coolant Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 1.1971 Edition. S'73 AMenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No AManda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufacturer National Other Year Replaced or Code Coruponent Manufaaurer Serial No. Board No. Identification Built Replacement Stamped YeaWo 3' Tilting Disc Check Anchor / Darling iN-345 N/A S21204MU021 1978 - Yes Valve 1/2* 13x36* All Nova Machine Heat 16925 N/A RSO 3299-93, N/A Replacement No Thread Products SA-453 Gr. 660B 1/2*-13 Heavy Hex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacement No Nuts (8) Products SA-453 Gr. 660B s

7. Description of Work:

The hinge pin cover studs and nuts were replaced with an altemate material with greater resistance to stress conesion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all thread material, with the required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCNF9659M

8. Tests Conducted: System Functional Pressure Test Pres: 645 psta Temp:N/A O -

w.=:=:=w.==== =:=.=== -

FORM NIS-2 (back)

9. Remarks : None.

m -,, u. v . .e- ~, CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this rentacement conformstotherules of the ASME Code, Section XI. repairerrep:_ n T)pe Code Symbolstamp: N/A Certificate ofAuthorizationNo: N/A ExpirationDate: N/A M Y Signed: / / Stmervisine ASME Codes Encineer Date: ' Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure VesselInspectors an -- the State or Province of California. and employed by Arkwicht MutualInsurance Comoanv (Factory Mutual Enelneerine Association)of Norwood. Massachusetts hjve ~ ed the cornponents described in this Owner's Report to 8/G/9 . and state that to the best ofmy knowledge and during the period M//4 /AV4 belief, the Owner haiperforined examinations and"taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. By siping this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, con examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with thisin 'on. hdA>nt Commissions M1 California National Board, State. Province, and Endorsements Inspector's Sipa'tufe f" ~ Date Mud. Q I9M i Mo: examacao

                                                                                                                                                    ~

p .

                                        ~

4 y:L FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ua m e,. % .rm.4weea, - t

l. Owner: Southern Califamia Edison Company Unit- 2
   /   \                      2244 Walnut Grove Avenue                                          MO:     93051205000,94100193000                       ;

C! Rosemead, California 91770 FCN: F9671M

2. Plant: Rspec : 135-94, GEN-139 San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&lD: 40112C N-5: S2 1204-15
3. WorkPerformedby: Southern California Edison Company Type Code S3 tnbol Stamp: N/A Authonzation No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition. S*73 Addmda Code Case None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repauwl, ASME Name of NameOf Manufacturer National Other N Year Replaced er Code F Manufacturer Scrial No. Board No. Identification Buits Replacement Stamped Yes/No 3* Tilting Disc Check AnchorDarling 2N-1411 N/A S21204MU155 1978 - Yes Valve 1/2*-13x36" All Nova Machine Heat 16925 N/A RSO 2991-93, N/A Replacement No Thread Products , SA-453 660B ' I/2*-13 HeasyHex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacement No Nuts Products SA-453 660B

   ,A          1/2*-13 Heavy Hex          Nova Machine       Heat 24848                N/A     RSO 299193,           N/A Replacement       No Nuts                       Products                                              SA-453 660B
7. Description of Work:

The hinge pin cover studs and nuts were replaced with an altemate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCN F9671M l i

8. Tests Conducted: System Functional Pressure Test Pres: 1511 osie  !

Temp: N/.A C) - 1

                   ;w w =a=:w:=ra:='=b:::e=.' c::r=--

n " Y C CM 9h ,, C V ) v vv

                           ~

FORM NIS-2 (b:ck) .

9. Remarks : The replacement bolting was ecrtified to a higher code class, ASME III-1, as allowed by ASME III, paragraph NCA 2134.

w- . . w -a s,, -- : CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ren1 cement conformstotherules of the ASME Code, Section XI. upak a reptuemes Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Signed: 8/ [M Supervisine ASME Codes Eneineer Owner or dwner's Designee, Title Date: NW CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orProvince of California. and empicyed by Arkwricht Mutus1 Insurance Comnany (Factorv Mutual - Eneineerine Aesociation)ofNorwood.Massnebusetts b ve ~ ted the coc2ponents desenkd in this Owner's Report during theperiod /,")/// /6/C" to /o/ 424~~~ . and state that to the best ofmy knowledge and belief, the Owner has p'erfor:6ed examinations and taken ceirrective measures described in this Owner's Report in accordance with the requirtments of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations a:id corrective measures described in this Owner's Report. Ftuthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thisir "on. [ #A ,r. add e ~ Commissions / /If - California Inspect'oP' s tij;naturd \ National Board, State, Province, and Endorsements Date . MI, /NT

    ,/                 '

e OIO OO 93O l} l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4 sea.n -..re.asiac.*-=

1. Owner: Southern CaliforniaE&aan Company Unit: 2 2244 Wilnut Grove Avenue

[~j)

 \                          R-a. California 91770 MO:    93051206000,94100193000 FCN: F9669M Rspec : 130-94, GEN-139
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40112AC 1 N-5: S2-1204-11 i
3. WorkPerfannedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A AuthonzationNo: N/A
4. Identification ofSystem: SafetyInjection and Shutdown Cooling ExpirationDate: N/A
5. (a) Applicable Construction Code ASME Section IIL Class 2.1971 Edition. S'73 AAAanAm. Cnde Case
  • None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No A AAanda
6. IdentiScation of Components Repaired or Replaced and Replacement Components:

Repairaf. ASME Narr.e er Nameof Manufamurer National Other Year Replaced or Code Component M - h =or SerialNc6 Board No. Th h Buik Rept====d Stangud Yes/No 4" Tilting Disc Check AnchorDarling 2N-874 N/A S21204MUOl7 1977 - Yes Valve 1/2*-13x36" All Nova Medduc Heat 16925 N/A RSO 3299-93, N/A Replacement No nread Products SA-453 660B 1/2"-13 HeavyHex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacened No Nuts (8) Products SA-453 660B p d

7. Description ofWork:

He hinge pin cover studs and nuts were replaced with an altemate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces.

Reference:

FCN F9669M

8. Tests Conducted: System Functional Pressure Test Pres: 1486 osir Temp: E O -

w====e==== =.. o====- ' i

                              ~

FORM NIS-2 (back) I

9. Remarks : The replacement bolting materials were certi5ed to a higher code class, ASME III-1, as allowed by ASME I III,parag aph NCA 2134.
                                                     ;-           _, w =         m                                                 {

CEREFICATE OF COMPLIANCE l We certify that the statements made in the report are correct and this renlacement conformstotherules  ! of the ASME Code, Section XI. repairorrept c ama ' Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Siped: unervidnc ASME Codes Encineer Date: 4 Owner or Dwner's Desipee, Title i CERTIFICATE OFINSPECTION  ! I I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Califomla and employed by A rkuriebt Mutual Insurance Comnany (Factorv Mutual ' Enrineerine Assoelation) of Norwood. Massaebusette hyvfjpspected the cornponents described in this Owner's Report , during the period //44/G(~ to fe/S6./vf . and state that to the best of my knowledge and  ! belief, the Owner has pdfoinied examinations an'd taken conective measures desenkd in thi,s Owner's Report in accordance with the requirements of the ASME Code, Section XI. l By siping this certificate, neither the Inspector nor his employer makes any warranty,ra-- M or implied, conceming the  ! examinations and corrective measures desenhd in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ' 'on. [ #/le h Inspector's Sipature'

                                              ~

Commissions /Ilv2 Califomia

                                                        \              National Board, State, Province, and Endorsements
                                                        \

Date-J

                         %IW  '

O b . .

g FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Reemed byh h ofb ASW Cok $scomM

1. Owner: Southern California Edison Company Unit: 2
 -(',                       2244 Walnut Grove Avenue                                                             MO:       93051207000,94100193000 Q                         Rosemead,Califomia 91770 FCN: F9673M
                                                                           .                                     Rspec : 13194, GEN-139
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40113A N-5: S2 1204-5
3. WorkPerformedby: Southem Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 1.1971 Edition. S'73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of Name of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 12" Tilting Disc Anchor / Darling IN-179 N/A S21204MUO40 1976 - Yes Check Valve 3/4"-l0x36" All Vitco,Inc. Ht. Code NBM N/A RSO 0318-94, N/A Replacement No Dread SA-453 Gr. 660B, CCase 1649 3/4"-10 Heavy Hex Nova Machine Heat 74853 N/A RSO 1846-94, N/A Replacement No Nuts SA-453 Gr. 660B l'- a (.J

7. Description of Work:

The hinge pin cover studs and nuts were replaced with an altemate material with greater resistance to stress conosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCN F9673M

8. Tests Conducted: System Leakace Pressure Test Pres: 647 psia Temp: N_/A l

V = -

                   .      ~..w          - .r                           - m..                        .m.                 . m it ,.             -                  ~
3) each ahem o numbered and en surnher ofsheets a seemded at tw kg of tus farm. and M each sheet a swunkd and deced by tw O=nst er Owner's daugnes and tw A1A.

[ _ l FORM NIS-2 (b:ck) t

9. Remarks : None.
                                                      % e          ==.r-aw.%         a CERTIFICATE OF COMPLIANCE We certtfy that the sute ments made in the report are correct and this renlacement conformstotherules of the ASME Code, Section XL                                          repererreptuanent Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A                     ExpirationDate: N/A                                                            I Siped:             [           N           unenisine ASME Codes Encineer           Date:       [            f Owner or Owner's Desipee, Title                                                          '    '

CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance comnanv (Factory Mutual - -= Eneineerine Association)pf Norwood. Massachusetts haye i ed the components described in this Owner's Report - during the period //.d/G6 to ,94G/G - . and state that to the best of my knowledge and belief, the Owner has pedornied examinations and tMe'n t!ctrective measures described in this Owner's Report in accordary;e with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any ustranty, expressed or implied, concerning the  ! examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his  ! cmployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or  ! connected with this ~ ion.

                           . Awf82M' inspec' tor's Sipature /

Commissions MN Califomia National Board, State, Prosince, and Endorsements Date AuO, . 9, f995 l l l l l l l W: 93051207000 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. m.,*ed sv es e-uson..re. Asm e.d. s.es xl 1

_ l. Owner: Southern Califomia Edison Company Unit: 2 ( 2244 Walnut Grove Avenue (,T/ Rosemead, California 91770 MO: FCN: F9674M 93051208000,94100193000

                                                                               .                                        Rspee 132-94, GEN-139
2. Plant: San Onofre Nuclear Generating Station P&ID; 40113A San Clemente, Califamia 92674-0128 N-5: S2-1204-4
3. WorkPerformedby: Southern Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section III. Class 1.1971 Edition. S*73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaared. ASME Name of Nameof Manufacnacr National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped. _ ,_ YeuNo 12" Tilting Disc Anchor / Darling IN-181 N/A S21204MUO41 1976 - Yes Check Valve 3/4"-10x36" All Vitco,Inc. Ht. Code NBM N/A RSO 0318-94, N/A Replacement No "Diread SA-453 Gr. 660B, CCase 1649 3/4".10 Heasy Hex Nova Machine Heat 13564 N/A RSO 1846-94, N/A Replacement No Nuts

p) SA-453 Gr. 660B '

Q.)

7. Description of Work:

The hinge pin cover studs and nuts were replaced with en altemate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the required markings being transferred to the cut pieces. A VT 1 examination was performed on the replacement bolting.

Reference:

FCN F9674M

                                                                                                                                                                                                        -l 1

l l

8. Tests Conducted: System leaksee Pressure Test Pres: 648 psia Temp: N/A (A) v i

No7E:

              *.,,L.wntal sherk m Ow form of bsts. shsubes. er sommes may be used pnmded (!) mee is $ 1/2 n a il sq (2) rJormaban en hems 16pough 6 on the report b included on each sheet j
3) sech ehest a membered and the number of shoes a secorded at tw top of Gus farnt and (4) each sheet is inshaled and deced by tw Ownes or Owners designse and ew ALA 1

l l

b - FORM NIS-2 (b:ck)

9. Remarks : None.
                                                     ,        ..- ,,m. ,, _

CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this reolacement conformstotherules of the ASME Code, Section XI. repair er replaecmers Type Code Syrnbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped: Supervisine ASME Codes Engineer Date: T Owner or Owner's Desipee, Title ' CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvince of California. and employed by Arkwricht MutualInsurance Comosnv (Factory Mutual - - Ensincerine Association) of biorwood. Massachusetts b ve inspected the components described in this Owner's Report during the period /M/GF to M/G _ C . and state that to the best of rny knowledge and belief, the Outer has perfonned examinations and faken"corresive measures described in this Ownefs Repon in accordance with the requirements of the ASME Code, Section XI. By siping this certificate, neither the Inspector nor his employer makes any wananty, expressed orimplied, conceming the examinations and corrective measures described in this Outers Report. Furthennore, neither the Inspector nor his employer shall be liabic in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

  • apection.

A44#2rA ~ Commissions M4I Califomia Inspectors Sipatur/ National Board, State, Province, and Endorsements Date buQ, A, f9QA" W h MO: 93051208000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A.am e. m ore. A5MICode SAM

1. Ouner: Southern California Edison Company Unit: 2

[] V 2244 Walnut Grove Avenue Rosemead, California 91770 - MO: 93051209000,94100193000 FCN: F9676M

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&lD: 40113B N-5: S2-1204-2
3. Work Performed by: Southern CaliforniaEdison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification ofSystem: SafetyInjection and Shutdown Cooling ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1971 Edition. S*73 AMmda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. p ;ro.% Built Replacemers Stamped Yes/No 12" Tilting Disc Anchor / Darling IN 183 N/A S21204MUO43 1976 - Yes Check Valve 3/4"-10x36" All Vitco,Inc. Ht. Code NBM N/A RSO 0318 94, N/A Replacement No Thread SA-453 Gr. 660B, CCase 1649 3/4*-10 Hensy Hex Nova Machine Heat 13564 N/A RSO 1846-94, N/A Replacement No m Nuts SA-453 Gr. 660B

7. Description of Work:
        'Ihe hinge pin cover studs and nuts were replaced with an alternate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN 139, eight studs were cut to the proper size from all-thread raaterial, with the required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCNF9676M

8. Tests Conducted: System Leakace Pressure Test Pres: 645 psia Temp: N/A
  " If.GKN.SIo*.'.N.ArY,."al.'[mY. orNNIEI.5MU[ od.Yo. I.D.*a7E

FORM NIS-2 (b:ck)

9. Remarks : None.
                                           .            ,, w ~~ w w CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonnstotherules of the ASME Code, Section XI.                                        repir erreptuement Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A                 ExpirationDate: N/A Siped:                                 Suoervisine ASME Codes Encineer            Date:          8 Owmer or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors a the State or Province of California. and employed by A rkwrfcht Mutual Insurance com nanv (Factorv Mutual               - --

Enrineerine Associstion) of Norwood. Massschusetts havein ed the components desented in this Owner's Repon during the period /M/GS to M/G . and state that to the best ofmy knowledge and belief, the Owner has p6rfo/med examinations and tfken dorrective measures dese:ibed in this Owner's Pqort in accordance with the requirements of the ASME Code, Section >3. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conc examinations and corrective measures described in this Outets Repon. Funbermore, neither the Inspector nor his employer shall be li2ble in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with thisins tion.

                     /)Xd2///I                 Commissions /MM                             Califemia Inspecicir's Sipature #'

National Board, State, Province, and Endorsements Date kfA9' .Q f99$

                                                                                                                            )

FORM NIS-2 OWNER'S ua REPORT FOR REPAIRS OR REPLACEMENTS e>yei,r, an Ashae.d.s oo

1. Owner: Southern Califamin Edison Compar,y Unit: 2 0 2244 Walnut Grove Avenue Rosemead,Califomia 91770 MO: 93072001000 Rspec 205-93 P&ID: 40134A G-7
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 N-5 *- S2-1212-5
3. WorkPerformedby: Southern Califamia Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identification ofSystem: NuclearPlant Sampling
                                                                                                                                                                                                                                              * * *                                 ^
5. (a) Applicable Constmetion Code: ASME Section III Class 2.1971 Edition. S*73 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized far Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer National Other Year Replacedor

  • Code' Componers Manufacturer Scrial No. Board No. Identification Built Replacement Stamped Yes W 3/4" Y type Globe Kerotest IUI 2 N/A S21212MU294 1976 - Yes Valve Disc Kerotest ARP18-8 N/A RSO 2485-91, 1991 Replacement Yes 9915-9-(l) l
7. Description of Work:

The valve disc was replaced due to seat leakage. l

8. Tests Conducted: System Functional Pressure Test Pressure: 2254 nsis Temp: N/A O NOTL ? ,. "

_ sheets an Sw fans afhsta, shaches, er 1 m. say be used gwo.wird (1)apu a 8 la et a il sL C) m hems i Ovough 6 en the separt s included am sect. sheet.

3) each shes a nenhand ered av mwnber of shese a escarded at pu sop ef tus fann, and(4) each shuss a sunnho mW dated by Ow Osmer av Owners designes and the A1JL

FORM NIS-2 (baek)

9. Remarrs: The replacement dise was ceni5ed to ASME HI 1, as allowed by ASME HI, paragraph NCA-2134.

ws .=,,,a.anr.aup . - ; CERTIFICATE OF COhELIANCE We eenify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair orreplacement Type Code Symbol Stamp: N/A Certi5cate ofAu' orizati No: N/A ExpirationDate: N/A Siped: 6 M Owiler or Osmer's Desipee, Title Lm.i ASME CodesEncineer Date: 8/' CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comnanv (Factory Mutual ,_ Enrincerine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report ... during the period WJB/G5 to 6 /4f/ Q T . and state that to the best of my kno'wledge and belief, the Owner has ti erfamied examinations and faken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector not his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this in "on.

                       #JXfd/ M     -

Commissions /I6A California inspectors Sipaturee Nationai Board, State, Province, and Endorsements Date 02/A A _fQ9T '

              //

o: 9mmu 1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u ne, ed by e.pr e .rs=4sia c.* s nxi sa.o .f A ,

1. Owner: . Southern California Edison Company Unit: 2 CN

(,) 2244 Walnut Grove Avenue Rosemead, California 91770 MO: 93080054000 Rspec: 223-93

                                                                          .                                     P&ID: 40114B G-4
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5 ~ S2-1206-1
3. WorkPerfonnedby: Southern California Edison Company Type Code Symbol Stamp: N/A Authonzation No: N/A
4. Identification of System: Containment Spray
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition. S'73 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda l
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesHo l' Y type Globe Kerotest TNE6-4 N/A S21206MR017 1976 -- Yes . Valve Disc BW/IP Inti. 4 N/A RSO 3450-93, Pan 1993 Replacement Yes l 72609993

                                                                                                                                                                                    ]4 b

O

7. Description of Work:

The Kerotest drain vahr in plant location S21206MR017 was disassembled for inspection due to heavy boric acid build-up on i the valve body. The vahe was cleaned, and the damaged parts were replaced. The valve disc was the only pressure retaining i pan replaced. A system functional test could not be performed due to the system configuratien (open ended), IWC-5222(c). A local leak test was performed with satisfactoryresults. {! I 1 I

8. Tests Conducted: H% Pressure: N% Temp: U]%

b v =u s,e. . 5 . % ei . .e es + d , d m . n . .i,,, o .r .iie . . .e,.n. d e.a = M and shes, e eumbered and e. nwaher of she,ts a see.eded ei 6. e.p of Om fa,m, and (4)each sheet a .vnnled and dated by 9. Owne er owner's desgnes and G. AIA.

1 FORM NIS-2 (back)

9. Remarks : The replacement dise was certified to a higher code class, AshE III 1, as allowed by AShE III, paragraph NCA-2134
                                                    === u        .cc. s upon, n. .m, .

CERTIFICATE OF COMPLIANCE ' We cenify that the statements made in the repon are correct and this renlacement conforms to therules of the AShE Code, Section XI. repair or replacenent Type Code Spnbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: 8/ / Sunervisine AShE Codes Encineer Date: _ f *J 5 Oumer or Owner's. Designee. Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California.and employed by Arkwricht MutualInsurance Comnanv (Factorv Mutual En cineerinc A ssociation) of Nonvood. Massschusetts have inspected the components described in this Outer's Repon during the period 3

  • 7 - 'M to 7-3/~'75 , and state that to the best of my knowledge and belief, the Oumer has performed examinations and taken corrective measures described in this Outer's Repon in accordance with the requirements of the AShE Code, Section XI.

By signing this cenificate, neither the Inspector nor his empicyer makes any warranty, expressed or implied, concerning the examinations and conective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or conn with 'sinspec bn. h ctXLT b dC'n Commissions California A-[ Inspector's Signature National Board, State, Prodnce, and Endorsements Date I, Ob a 1 Wl B30600$4000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As n.i, d by su enm.or..fe. Asur cod.s nxi

1. Owner: Southern Califomia Edison Company Unit: 2

/ 2244 Walnut Grove Avenue MO: 93080073000 () Rosemead, California 91770 FCN: F10974M Rspec : 216-93

2. Plant: San Onofire Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40134A C-7 N-5: S2-1212-6
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A
4. Identification of System: Nuclear Plant Sampling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III Class 1.1974 Edition. S'75 Addenda. Code Cases- 1539.1580-1 (See B.emaid (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer National - Other Year Repk W or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped - Yes/No 3/4" Globe Rockwell AN602 N/A S21212MU296 1979 Repaired Yes Herma-valve Intemationa! . Disc Rockwell Lot H3584 N/A RSO 2-P-1448-81 N/A Replacement No Intemational Bonnet Rockwell Lot H5760, Heat N/A RSO 2-P-2128-83, 1983 Replacement Yes Intemational X15979 SA479 Tp 316 f) U

7. Description of Work:

ne valve was disassembled for inspection due to seat leakage. The body-to-bonnet seal weld was removed to allow replacement of the valve disc and bonnet. The body-to-bonnetjoint was then seal-welded in accordance with FCNF10974M and weld record WR2-93-502.

8. Tests Conducted: Svstem Functional Pressure Test Pres: 2255 nsia Temp: N/A v

NOTE: Sussarmental sluem m tw forra ornsas, skeisham, er dresumgs any be used provuled (0 na m 8 l!2 m a il n. Q) mformanon a hems I $wough 6 ce #im report a meluded on each sheet, 3)each sheet a numtweed and tw msnbar of sheen a rueerded at $m top of the fog and (4)each sheet a sunnled and daned by on Owner er Oumers daugnee and Ow AIA

FORM NIS-2 (b ck)

9. Remarks:

This class I valve is currently installed in a class 2 syrfm. as allowed by ASME III, paragraph N v;; m.r.= % ~ , CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this of the ASME Code, SectionXI. renlacement conformstotherules upair ornptacement Type Code Symbol Stamp: N/A Certificate ofAuthonzation No: N/A Expiration Date: N/A Signed: _

                                        / Supervisinr ASME codes Encineer Owneror Owners Designee, Title Date:  f/7/35 CERTIFlCATE OFINSPECTION the State or Province of California. and employed by Arkwricht M                                                   .

Eneineerine Association) during the period a/ p/8/Mf to-Norwood. Mas sachusetts have inspected the componen 6/4/6 belief, the Owner has performed examinations and taken corrective measures dese accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any wananty, ex examinations emp and corrective measures described in this Owners Report. Furthermore, neither the I Ger, centect sha!! be with liabic in arymanner for any personal injury orproperty damage or a loss of an m:tiyn., Swet ( en / bI7& Commissions _ Califomia AH[ Inspectors Signature National Board, State, Province, and Endorsements @ l D w wk $,l.9]5 l m :c = = xxo _l I I 1 l

r. .. . . . . . . . . - . -- .. - - - - - - - - - - - - - - - - - - . - - - - - - . - - - - - - - - - - _ - - - - - - - ,

i-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS  ; u n ediru p .f=unae.d.s x m.asau

1. Owner: Southem Califomia Edison Company Unit: 2
    ' /m)                                              2244 Walnut Grove Avenue                                                               MO:                    93080076000 V                                                 Rosemead,Califamia 91770                                                               Rspec GEN-027 P&ID: 40124A E-2
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N 5~- S2-1201-6
3. WorkPerformedby: Southem Califomia Edison Company T)pe Code SymbolStamp: N/A  ;

Authorization No: N/A J ExpirationDate: N/A

4. Identification ofSystem: Reactor Coolant j I

l S. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 Addenda. Code Cases None i (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repausd, ASME Name of Nameof Manufacturer National other Year Replaced or Code Corryonent Manufacturer Serial No. Board New IdentiGeation Built Replacement Stamped YesNo l 3/4" Nozzle Type Crosby Valve & N60065-00-0005 N/A 2PSV9215 1986 Replaced Yes . , ReliefVahe Gage 1 3/4" Nozzle Type Crosby Valve & N60065-00-0004 N/A RSO 4239-85 1985 Replacement Yes - ReliefValve Gage

7. Description of Work:

j The valve was replaced due to leakage between the valve base and the cylinder. The removed valve was placed into the rebuild program. 1

8. Tests Conducted: System Functional Pressure Test Pressure: 2250 osia Temp: Fj/A NOTE: S,,
                                               . shout a tu fem of hsm, eheishes, or drewegs may be used provided (1) as b 81/2 at a 11 st.Q) afarmenan ei tums I 6emgh 6 en sus report a enetuned on each aluet.

3)ensh shest a manheres and tu seember of sheen a sneerded at eis any of dus farin, and(4)each shest a summled and emesd by te Owner er Owners desgner and the m l--i ir

FORM NIS-2 (bock)

9. Remarks : None.
                                                 %-.- mnen.ww                 . w; CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this rentacement conforms to the rules of the ASME Code, Section XI.                        repair or replacement Type Ccde Symbol Stamp: N/A Certificate ofAutho:ization No: N/A                 Expiration Date: N/A Siped:              [                  Surenisine ASME Codes Encineer            Date:         8 6
           - Owner or Oufers Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsuranee Comoanv fFactorv Mutual are '

Eneineerine duringthe period Association) 8//3 /9d of Norwood. to 8/ Massachusettsp/ /9 ected the components described

                                                                           . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owmer's R eport in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conc examinations and corrective measures described in this Outer's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected iththisinsp ction. t24 e d 0 Commissions / California [ Inspector's Sipature National Board, State. Prosince, and Endorsements Date $ Ih5 l . . - - 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.a ed>ye. ore.uwea.s xi

 /~N
1. Owner: Southern California Edison Company Unit: 2 2244 Walnut Grove Avenue C) Rosemead, California 91770 MO: 93080093000 Ripec: 217-93
2. Plant San O%&e Nuclear Generating Stat 2on P&ID: 40111A D-6 Sara (;1emente, California 92674-0128 N-5-* S2-1212-5
3. Work Performed by: Southern CaliforniaEdison Company Type Code Symbol Stamp: N/A AuthorizationNo: N/A
4. Identification ofSystem: NuclearPlant Sampling
                                                                                                                               **                  ^
5. (a) Applicable Construction Code: ASME Section III. Class 1. I971 Edition S'73 Addenda. Code Case: None (See Remarksi (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of Nameof Manufacturer National Other Year " Replacedor ~ Code' Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 3/4" Y-type Globe Kerotest BAE21-9 N/A S21212MR219 1979 - Yes Valve Disc Kerotest ARPl718 N/A RSO 2779-90, 1990 Replacement Yes 9915-9-(l) (m) v

7. Description of Work:

The valve disc was replaced due to leakage from the pipe cap.

8. Tests Conducted: System Functional Pressure Test Pressure: 2256 nsia Temp: N!%
 ,m

_. .. -..__.,_._,,_._.,,__.-t._c,.._.___

3) each shee a menbared and om an.nbar of shesu s roernded at Ls tem of the foran, and (4) each shed a puheled and daud by em Owner or Osmar's dessnee and em A1A.

4 FORM NIS-2 (b:ck)

9. Remarks : This class ! valve is currently installed in e class 2 system, as allowed by ASME III, paragraph NCA-2134.
                                                  %            =. r ag =. w - i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of the ASME Code, Section XI.                            repairorreplacement Type Code Spnbolstamp: N/A Certificate ofAuthorizationNo: N/A                       Expiration Date: N/A Siped:            /                        Suoervisine ASME Codes Enrineer          Date:       8 fN' 6 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwriebt MutualInsurance Comosuv (Factory Mutual                              ,. .

Encineerine Associatlon) of Norwood. Massaebusetts have inspected the components described in this Owner's Report - - - during the period e9/14/R3 to R M / Q S - . and state that to the best of my knowledge and belief, the Owner has p(rfornied examinations and'tarc'n corrective measures described in this Outer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec 'on.

                          #A#1hn                      Commissions      lblS-                      California Inspector's Signature [                                       National Board, State, Province, and Endorsements Date $/A d /.9GE V

Ne

6 m , y , , c. -- .

                                                                                                                                                             .                c    a :~       .              U-    . .   .      .         - . . .
                                       ;;^                                             .
                               $p             -
                                       * : g.
                                            'l '                                                           PORM N15-2 OWNER'S REPORT POR REPAIRS OR REPIACEMENTS a.n.,s ee,e om.em..re m eo.=s.sh m
  • J' N.
                               )                                                                                                                                              .                   ,

Sheet 1 of 1 Asd 1.' Owner: Soushara QEforala Edison Company . Unit: 2 j- 2344 Walnut Geove Avenue, Renamend, CA F1770 MO: . 93090873

                                                                                                                                              .        .                                RS:           23043,Rev.0
2. Plant: - Een Coolke Nedser Gemaradag Smelon P&lD: ' 40141D (54)

P.O. Das 128, saa casamer, CA 936744128- N-S: 52 1301-1

3. Work Peiforened by: Sousbern California Edison Compesy .1)pe Code Symbol Stamp:
                                                                                                                                                                                      .                                    N/A i         I                                                                                                                                                                              Anchorization No:                  N/A
4. Identificadon of System: Main Semans Expiration Date: N/A S. (a) Apphenble Construeden code: ASME secdos BI, Class 2,1974 Edidae,574 Addende, code r h* Nome -

(b) Apphcable Edidon of Secdon XI Udlized for Repairs or Replacements: 1977 Edition,Ir79 Addeda

6. Identificadon of Components Repaired or Replaced and P=p=---- --t Components:

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Idendfication Built Replacement Stamped Yes/No A= . -* Dump Valve Babcock & Wilcox 18447-3-1 N/A 2HV8419 1979 Repaared Yes (8" x 12") .

7. Description of Work:. \

l' 1he threaded joint at the We bonnet drain line (S2-1301 MIr921) to valve bonnet was seal welded on atmosphenc dump a valve 2HVH19. A PT esamination was performed on the completed seal weld. ,

References:

FCN F8713M, WR2-93-537

    .i                                                                                                                                            s i                                                                                                                                            \                                                                                                l
   .s                                                                                                                                                \                                                                                              1
      =
                                                                                                                                                                                                                                                    \

1 I l

                                                                                                                                                                                                                                                'l
                                                                                                                                                                                                                                                 'i
8. Tests Conduc'ted: System Isakage'[] Systero Funcdonal [X] System Inservice [ ] Hydrostade [] Pneumatic [ ] Other []  ;

Pressure: 380 psig Temp: N/A i 1 (.* ? Note: Supplemental sheets in the form of lists, sketches, or drawings may be used pronded (1) size is 8 % in. x 11 in, (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recon %d er the too of this fann.

                               .                                        FORM NIS-2 (back)
9. Remarks: None (Applicable Manufacturers Data Reports to be attached) <

CERTIFICATE OF COMPLJANCE We certify that the statements made in the report are correct and this Ignir conforms to the rules of the ASME Code, Seedon XI. Type Code Symbol Stamp: N/A Cestificate of Authorizadon No: N/A Expiradon Date: N/A Signed: e /[ .Supervisinr ASME Codes Enrineer Date: / /k

                                                                                                                                              . 39~8 I Owner or Owhefs Designee, Tide
 .                                                               CERT 1FICATE OF INSPECYION 1, the undersigned holding a valid commission issued by the Nadonal Board of I!oller and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwrirht MutualInsurance Company (FadorY Mutual Er.Gedii Associadon) of Norwood. Massachusetts have in3pecte4the components described in this owner's Report during the period W ///7/ W "6             to   ///7/8// . and state that to the best of my knowledge and belief, the Owner has' peifonned 6xaininations and/aken c6rrEcdve measures desenhd in this Owners Report in accordan'ce with the requirements of the ASME Code, Section XI.                   ,

By signing this certificate, neither the Inspector nor his employer ma kes any warranty, expressed or implied, concerning'the , examinadons and correedve measures described in this Owners Report. Furthermore, neither the Inspector not his employer shall

                                                                                                                                                          ,\

f be liable in any manner for any personal irduty or property damage or a loss of any kind arising from or conn, acted with this q g inspection.

                                  //2/Wf'28 A                      '

Commissions ~

                                                                                               /     1                   California "Inspfct'or's STgnargf                       '

(Nadonal Board, State, Province, and Endorsements ) Date _ 44, / 7 , 19

                                                     ~

[ D l'

.......a 4
             .1                                   ,
                                                                                                                               . PORM NIS-2 OWNER'S REPORT FOR REPMRS OR REPLACEMEIGS as n.psw my e e-en .ae ans cw.s.m a
D
'b -(,               1.               ' Owner: Soutbara California Edison Company.

Sheet 1 of 1 Unit: A 2344 Walnut Grove Avenue, ph, CA 91770 ' MO: 93100171 RS: 233-93

2. Plant: San Omote Nuclear 7
                                                                                                                                                        '; Stadon P&ID:        N/A
                          +

PD. Box las, Saa r h-m, CA 92674-0128 N-5: N/A

      ~
3. Work Performed by:~ Southern CaEfornia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identificadon of System: Main Steam Empiradon Date: ~N/A S. (a) Applicable Construction Code: ASME cvw=t BI, Oass 2,1974 Edhtion,574 Addenda, Code Cases: Nome (b) Applicable Edidon of Secdon XI Udlized for Repairs or Replacements: 1977 Eddon, S77 Addends
6. Idendficadon of Components Repaired or Rep! aced and Replace mt Components:

Repaired, ASME Name of Name of Manufacturer Nadonal Other- Year Replaced, or Code Component Manufacturer Serial No. Board No. Idendficadon BuDt Replacement Stamped l Yes/No 6* x 10" Main Steam Crosby N58737-00 0012 - N/A Spare 027 66749 1976 Repaired Yes j Relief Valve 1 l

                                                                                                                                                                                                                                                    \
7. Descripden of Work: '

Damage occurred to one of the valve body threaded inlet stud holes during shipment from the manufacturer. The Inlet stud ' hole threads were chased in accordance with WNCR WO480-93. I k9

s. Tests Conducted: System Isakage [ ] System I'unctional [ ] System Inservice [ ] Hydrostade [ ] Pneumatic [ ) Other [ ]

Pressure:N/A Temp:N/A To be perfonned upon installadon.

     }.                                                                                                                                                                 .
   .::i Note:             Sopplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 In, (2)

Information in items 1 through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is secorded at the too of this form. - -

FORM NIS-2 (back)

9. Remario: None (Applicable Manufacturefs Data Reports to be arrached) 1

{ f CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code, Secdon XI. Type Code symbol stamp: N/A Certificate of Authorizadon No: N/A Expiration Date: N/A Signed: .Sunervisine ASME Codes Enrineer Date: /4/Z4 .19M Owner or Ow'iiefs Designee, Tide CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the Nadonal Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by Arkwrkht Mutual insurance Company (Factory Mutual Enrinennr Association) of Norwood. Manchusetts have inspqef th components i described in this Owners Report during the period

         /O-7-43 to /# MK -Y 3 . and state that to the best of my knowledge and belief, the Owner has performed examinadons and taken correcdve measures described in this owners Report in accordance with the requirements of the ASME Code, Seedon XI.                                             -

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinadons and corrective measures described in this owners Report. Furthermore, neither the Inspector nor his ernployer shah k 4 be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ,

                            #4/uddh                                   Commissions       .

[> b California inspeftors Signature 7 (National Board, State, Province, and Endorsements } Date 4e j 19 G 9

a-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ua m =ri .cm asisc a,so m , . #. ;_h -

l. Owner: Southern California Edison Company Unit: 2 ,

2244 Walnut Grove Avenue MO: 93100206001 .V- Racar A. California 91770 Rspec- 006-94

                                                                                  .                                  PAID: 40141D F-3
2. Plant- San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2 1301-2
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
                                                                                                  -                          a n ae                        A
4. Identi5 cation of System: Main Steam I
5. (a) Applicable Construction Code: ASME Section M. Class 2.1974 Edition. S'75 AAAanda Code C==ae None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements; 1989 Edition.No AAAanAn
6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                                                                                               .Repased, ,        ASW    <

Name of Name Of Manufacturer National Other Year

  • Replacedor Code t'

Manufacturer SerialNow Board No. Irlardifientw' m Built Reptar===d Stamped Yes/No l' SW Gate Valve Henry Vogt 21-214966 N/A S2130lMU1000 1983 Replaced Yes l' SW Gate Valve Henry Vogt 24 216859 N/A RSO 3271-93, 1993 Replacement - Yes CR-88-007 '

7. Description of Work:

d The vah c was replaced due to body-to-bonnet leakage as described in NCR 9312004602. The valve wasinstalled bywelding i in accordance with weld record WR2-94-009. i l l

8. Tests Conducted: System Functional Pressure Test Pressure: 903 pmc Temp: N/A i O _. __.___.._...._a___,0_.__.___._

H emet, shut b nunehmed and en nienbar of shes. . fecorded at tw are of te farm and (4) each sheet . subalud and sheed by Ou Owaar a Owner's d.e.nse and to AIA

l FORM NIS-2 (b:ck) j

9. Remarks: None.

w _- - ,, n n , - . CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this . renlacement conforms to the rules of the ASME Code, Section XI. ,epair a rw Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Signed: Owner or Ouver's Desipee, Title Dunervisine ASME Codes Eneineer Date: [f' 5 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comnany (Factorv Mutust . ---- EnrIncerine A ssociation) of Norwood. Massachusetts hjve inspected the components described in this Owner's Rep --

                                //4 /J"X1 during the period                            to M4d/CS                      . and state that to the best of my knowledge and belief, the Owner has pefformd! examinations and (aken corrective measures desenkd in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemi examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any mannerfor any personal injury or property damage or a loss of any kind arising frora or connected with this ~ 'on. Inspector's Signature /

                                   #td//7f             Commissions       /MM                           Califomia     ,_

National Board, State, Prosince, and Endorsements Date M, M./dQ$ U Mo: 93100200001 1

                                                                                ' FORM NIS-2 OWNER iS REPORT FOR REPAIRS OR REPLACEMENTS us.w dhi == w       .rt. ASMBcohassemM m s.n                 '
              '1. Owner: . Southern Cahfarnia FAgenn Company                                                                                                                   _ Unit: . 2 t                                                                                    2244 Walnut Grove Avenue                                                                  MO: 93100519000
 '\                                                                                   Pa-ne=<t, Cahfornia 91770                                                                  Rapoc 097-94 PAID: 40156C H-5
2. Plant: San Onofre Nuclear Generating Station N-5*- S2-1305-7 San Clemente, California 92674 0128
3. WorkPerfannedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A.
                                                                                                                                                                               ' AuthonzationNo:          N/A
4. Identifw ahan ofSystem: Feedwater
5. (a) Applicable Construction Code: ASME hreiaa III. Plaan 2.1974 FAidnn S'74 AAAawla raA.re None (b) Applicable Edition of Section XI Utihzed for Repairs or Rep 1= nan =*=- .1989 Edition.No Addenda 4
6. Identification of O-- ; =2= Repaired or Replaced and Replacement C---; =- 2--

Repened, ASME Nanu of Nante of M=h-er , Nahanal Osbar Year Raylened or Cods c hh-ar BW SerialNo. BosnlNo. M=hna=hast Bulk senaped Ysseio 1/2* x 3/8' Male Swagelok Ht.R12IM0500B, N/A RSO 1121-93 N/A Rep 1=aament No C-ae SS-600-1-8

7. Description ofWork:

The tube male ennnerenr between isolation valve S21305MR850 and the bushmg adapter at the actuator dome was replaced due to N2 leakage. The existing tubing was reused. l. 1

                                                                                                                                                                                                                                '1 I
8. Tests C*~l: System Fnar*lan=1 Pr --e Test _

Pressure: 1550 osir Temp: N/A i M" W desRI 5t Of lum 0% N Gr W may be med pusended(1)e b 8 /26L a II k (D h h hm I W 6 en h w h histmend a and M

3) sash shes b membasse and es member of shesh a mussdad a $s tap of Gus funn, and ($ sash shast a huhuled and dated by he Ouest er Osmart emuytus and es AIA.

FORM NIS-2 (back)

9. Remarks: Ncce. '

n , a. % ,, m CERTIFICATE OF COMPLIANCE We certfy that the statements made in the report are correct and this renlacement conformstotherules of the ASME Code, SectionXI. npair arreptacement Type Code Symbol Stamp: N/A - Certdicate ofAuthorizationNo: N/A ExpirationDate: N/A Signed: 88 b Supervisine ASME Codes Encineer Date: MM/95 Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure VesselInspectors and the State orProvince of California. and employed by Arkwricht MutualInsurance Comnanv (Factorv Mutual Enrineerine A ssoelationlof Norwood. Massschusetts have inspected the 9 ;=xe desenkdinthis Owner's Report during theperiod ff/849#- to 7//R/9<~ . and state that to the best ofmyknowledge and belief, the Owner has p'erfarined examinatices and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his empicycr makes any wananty, ,M or implied, concerning the examicstions and corrective measures desenhd in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury orproperty damage or a loss of any kind arising from or ceanected with this * - on.

                                                   \ nmmi" C         tons /IS2_J                       Califomia Inspector's Signature /                                  National Board, State, Provmee, and Endorsements
                                                      \s i

Date M7./696~

            /      (l v

l

{~f 4 ,  : -w .

                                                                                                        +

a 1 . PORM NIS-2 OWNER'S REPORT POR REPAIRS OR REPUGMENTS aa e nye si as-..ta. masc s.-m , r

    ;(
    ,.,           ~
     A                                                                                                                   Sheet 1 of 1 M' '                     2.        Owner: Southens California Edison Company                                           Unit:              2-2344 Walnut Geese Avuone, Rasemand, CA 91770 -                         ' MO:                93101071 RS:                259 93
2. - Plant: . San Onofra Nudmar Genssating stadoa PadD: ' 40123C (54) l PD. Box 124, Sam h, CA S3674 0128 N-S: 53l h 11  !
                            '3 .       Work Performed by:               Southsea Califorala Edison %                     ~ Type Code Symbol Stamp:                       N/A Authorizadon No:                              N/A                        !
4. Identincadon of System: th-d.=1 and Vohame Coottal Expiration Date:- N/A.
                           - S..       (a)        Appbcable Construcdon Code: ASME Secsion EI, Class 2,1971 Edidos,573 Addenda, code Case: Nome                                                 s!

l (b) Applicable Edition of Secuan XI UtGised for Repairs or F=.=?= - - 1977 Edloon,579 Addenda  : ) i

6. Identificadon of Components Repaired or Replaced and Replacement Components:

Repnred, ASME .i Name of - Name of ' Manufacturer Nadonal Other Year Repla ad, or Code l

l. Component
                                             ~'

Manufacturer Serial No. Board No. Idend5cadon Built Replacencet - Stamped i Yes/No i 1%" Globe Valve Kerotet YG13-23 N/A S21208MU107 1978 ... Ye I I Duc Eerotest AJU6-2 N/A RSO 5912-44 1984 Ilet Ye

7. Description of Work:  !
                                                                                                                                                                                                -l
                                       *Ihe Kerotet valve was duassembled to comet a seat leakage problem. *the valve was reworked, a new dise was installed, and                                  !
          %                            the valve was reassembled.                                                                                                                                   !
          *W:   3
                                                                                                                                                                                                .]

4 1

                                                                                                                                                                                                  .I
8. Tests Conducted: System laakage [ } System Functional [X] System Inservice [ ] Hydrostatic [] Pneumade [ ] Other [ ] -

Pressure: 40 psig Temp: N/A e 1 f-I l j .' . V * . Note: Supplemental sheets In the form of lists, sketches, or drawings may be used provided (1) size is a % in. x 11 in, (2)  ! infonnadon in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of j sheets is recorded at the top of this form.

                                                                                                                                                                                                   ]
                                                                                                -    -n     + --       w         - - - . -,          , - , - -       -

FORM NIS-2 (back)

p. Remarks: The replacement disc was certified to ASME III, Class 1.
                                             * (Applicable Manufacturefs Data Reports to be attached)

{ CERTIFICATE OF COMPLIANCE We certify that the statements made ist the report are correct and this replacesnent confonris to the rules of the ASME Code, Secdon XL Type Code Symbol Stamp: N/A Certificate of Authorizadon No: N/A Ezpiradon Date: N/A signed: [ M* .Supervisinr ASME Codes Enrineer Date: / 7 ,19M Owner or Dwners Designee, Tide CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the Nadonal Board of Boiler and Pressure Vesse!Inspecton and the State or Province of California and employed by Arkwricht Mutual Insurance Coromy (Factory Mutual EAbi Association) of Norwood. MmLws have inspected th components described in this (%vnets Report during the period

            /6-SW 'r ~3 to /#-ST                        3 . and state that to the be ; of my knowledge and belief, the Owner has performed eTaminadons and taken correedve measures described in thh C snets Report in accordance with the requirements of the ASME Code, Secdon XL By signing this cerdficate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the eraminadons and corrective measures described in this owners Report. Furthennore, neither the Inspector nor his employer shall      h be liable in any manner for any personal Irdury or property damage or a loss of any kind arising from or cormected with this Inspeedon.                                       t dM?df/M Inspecfors SignaturpV              N Commissions               b)                  California (Nadonal Board, State, Province, and Endorsements }

Date , M, lh8 6 3 i 5 i

? FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.a dbys=>== .,n.Asusc.*s.a m Elma 4 et 4

    ,_s         1. Owner: '- Southern Califomia Edison Company                                                                         Unit: 2 t                         2244 Walnut Grove Avenue d[ .                           Rosemead, California 91770 MO: 93110109000 Rspec: 286-93 P&ID: 40141C G-5
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1301-2
3. WorkPerfonnedby: Southem California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identification of System: Main Steam
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition _ S'73 A AA-nda (Valvel 1974 Edition. S'74 Addenda (Installation 1 Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaared, ASME Narne of Narne of Manufaaurer National Other Year Replaced or Code Component Manufaaurer Serial No. Board No. I" h Built Replaosment Stamped Yes/No l' Y type Globe Kerotest FAG 2-10 N/A S21301MU637 1981 Replaced Yes Valve 1* Y-type Globe Kerotest FAG 7-15 N/A RSO 2-P-52-84 1980 Replacement Yes Valve A Q 7. Description of Work: The valve was replaced due to seat leakage. The ASME III socket-weld was performed in accordance with weld record WR2-93-638.

8. Tests Conducted: System Functional Pressure Test Pressure: 904 osig Temp: N!%
                                                                                                                                                                                                )

s I

          =           _         -. . .w , .rm                                 ., i. w ,     d m . .                          , % .             .,

w . . . . se,. 3)each shes a numbered and tw senbe of shrees a sneerded at to 69.f fus % and (4) such sheet a senaled and deesd by su owner r owns,as de gnse and em ADL

c - FORM NIS-2 (b:ck)

9. Remarks : None.

n m. m upm. . % CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstotherules of the ASME Code, Section XI. repair c<reptuement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A ,7 3,/9g Signed: 8  ! Sunervisine ASME codes Encineer Date: ,#, S?, 4FM/ Owner or Owmer's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rlmricht Mutual Insurance Company (Factorv Mutual Encineerin e Association) of Norwood. Massachusetts haye inspected the components described in this Owmer's Report during the period #2/// W to '7/Kf/9A"' . and state that to the best ofmy knowledge and belief, the Owner has p'erf6rmedi:xaminstions an'd'taken corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owmer's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i. ection.

                                   ,#A                       Commissions      /ISS                       Califomia Inspe6 tor's Signature /                                      National Board, State, Prosince, and Endorsements Date
                /
                  .1

(/' E/ $6~~ I uo: n w oeoco

F

                                                                          '                                    it      m:
                                                                                           .                                       . u.           .;g
        '4                                                                                      .

FORM NIS-2 OWNER'SREPORT FOR REPAIRS OR REPLACEMENTS .

   . ,mg                                       As Reptred lyr the Provielers of the ASE! Code Section XI                                                      a
                                                ~

i$

 . t %-) -

i

   -(;9 :.

Sheet i of 1 )

1. Owner: Sou6sra Cardbres Edison Coupesy . Unit: 2 ,

2144 Walam Grove Avemme. Rassened, CA 91770 CWO: 93111171000  ! 93111100000- J

2. Plant: Sea ono6e Nacient e --- . Stados 93111843000 P.O. Box 128, Sea Clemasse CA 92674-0128 DCP: 2 4742.07-0 Pa!D: 40127J
3. ' Work Performed by: Badsel Consowena Coagemy N-5: N/A' P.O. Box 450 , ,

Sea ha CA 926740128 Type Code Symbol stamp: N/A , Authorization No: N/A 4 Identification of System: e , - Cooling Wear (1203) Expiration Date: N/A

5. (a) Applicable Construction Code: ASME Semon W. Class 2,1974 Edinam, W'75 Addende Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 19Til:dison, S'79 Addaule i
6. Identification of Components Repaired or Replaced and Replacement Components: {

No conyoommes imputed Ibr tids emaias.

7. Ducription of Work:

Repair / Replace solenoid valvu 2HV6569/2HV6570, leak test valves. Hydro ponion of Line 821203ML478/479and hydro requirements ofinsta!!ad flar.ges on downstram s'ule of solenoid valves. Performed welds per WR5/WR$A's and WFMCR's: I CWO WELD 1.D. 93111177000 93111177 93111180000 93111180

                                                                                                                                                       ..     )

B. Tests Conducted: VT-2 for CWO's 93111177000/93111150000/93111843000- Hydrostatic [X] Pressure: 168.5psig Temp: 66*F O t e

7.. d FORM NIS-2 (back) ,

7. Remarks: Documentation (gitems listed in Block 6 are available on site. .

(Applicable Manufacturer's Data Reports to be anached) CER11RCATE OF COMPLIANCE We certify that the statemerns made in the report are correct and this nelacemear conforms to the rules of the ASME Code, Section XI. Type Code Syn 6ot Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: </ a+r /M - _uA d L . bW- ' Date: C 2 - / 6" . tpg Owner or Owner's D'esignee, Tide CERTIRCATE OF INSPECITON I,the undersigned holding a valid comrnission issued by the National Board of Boiler and Pressure Vesse! Inspectors and the State or Province of CaEfornia .and employed by Artwnzbt Murual Insusnee Ceacany (Factory Munaal Enrineerme Ammociadou) of Norwond. Massachunents . have inspected the components described in this owner's Report during the period /6/_-7/98 to _M/d/94/ and state that to the best of my knowledge and belief, the Owner has performed examinations'and taken correcave men'sures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI. By signing this certificate, neither the Inspector not his employer rnakes any wrrrardy, expressed or implied, concerning the ' exarninations and corrective rnessures described in this owner's Report. Furtermore, neither the Inspector nor his employer sha!! i be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. W

                                    /MAMM>t                              Commissions                8                 California tripector's Signature /                                             (National Boardl State, Province, and Endorsements )

Date . // /, 19 h l l ISI 1*nmar-- Review: TCLM N . b rikd Mk vnhn // Date: M"Il- k h l l 1 1

                                                                                                                                                       \

i M

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l 4.ne,*whysur====<n.Asusc.de - x 1. Owner: Southern CaliforniaEdison Company Unit: 2

 /   \                         2244 Walnut Grove Avenue                                                                   MO: 94010417000 1

l Af Rosemead, California 91770 Rspec: EREF-0142 l P&ID: 40141D E-8

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1301-1
3. WorkPerformedby: Southem California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A a n ate WA
4. Identi5 cation of System: Main Steam i
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 AAhda Code Cases: None ]

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaned. ASME Name of Nanwof Manufaturer National Otlwr Year - keplaced or

  • Code CW Manufacturer Serial No. Board No. Idenufication Built R7 - stamped Yes/No j 8" Drag Valve Babcock & 18447 3-1 N/A 2HV8419 1979 -

Yes Wilcox Valve Flug Control Heat 8080095 N/A RSO 2157-90 1974 Replacement Yes Components n

7. Description of Work:

The valve was disassembled for inspection due to seat leakage. The valve was cleaned and reassembled using a new valve plug. t

8. Tests Conducted: System Functional Pressure Test Pressure: 903 esig Temp: N/A Woft Supplanmuel sheris e ou fann orksm, dethes. er drawegs may te med prended 0) se e 8 la a a 11 sw C)mfannamon a hems I throtagh 6 en ths report a mishaded en each abast,
3) each sheet s numbered and the aunha of shoem a recorded at tu top of dis form, and (4)each sheet a tuteled and dated by the Owns er Owner's desgnee and the AIA j

i i

FORM NIS-2 (b:ck) .

9. Remarks: None.

e.- - . a. a p.n.  % CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rentacement conformstothtrules of the ASME Code, Section XI. repair er reptuemco Type Code Symbol Stamp: N/A Certificate of uthorization o: N/A Expiration Date: N/A Siped: lir i Owner or O'uters Desipee, Title Stmervisine ASME Codes Encineer Date: 8!k bi CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Comnanv (Factory Mutual . . Encineering A ssoelation) of Norwood. Massnehusetts have inspected the components described in this Owner's Report -- during theperiod Q/A/FM to cO/4/6 . and state that to the best ofmy knowledge and belief, the Owner has performed' examinations and'take'n corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this ce tificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ' 'on. [ . />sph Commissions 16;S California Inspecior's Sipa~ture/ National Board, State, Province, and Endorsements Date $/A A _fQW ' f/ dem. Mo: 94010417000 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS . u a.,*.dby m.ca.ma c s x men t att

1. Owner: Southern CaliforniaEdison Company Unit: A
 = (n                        2244 Walnut Grove Avenue                                                                   MO: 94011452000
 ' V)                        Rosemead, California 91770                                                                 Rspec GEN-112R1 P&ID: N/A -
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 N
  • N/A
3. WorkPerformedby: Southern CalifamiaEdison Company Type Code SymbolStamp: N/A Authornatw= No: N/A
                            .                                                                                           Expiration Date:                     N/A
4. Identification of System: N/A - Spare
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. S'74 A AAanda Code C=_=e None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements ,1989 Edition. No Addenda l
6. Identification of Components Repaired or Replaced and Replacement C-~= ants:

Raped. ASME l Narne of Name Of Manufacturer National other Year Code Replaced or- l Ce Manufacturer SerialNeu - Board No. Identdication Buik . * ,' Stamped  ! Yes/No 11/2' x 2' Nozzle Crosby N59380-004008 N/A 025-83508 Spare 1984 - Yes Type Relief Valve Disc Crosby N91241-46-0080 N/A RSO OO88-93 N/A Raplu -a'* No Spindle Crosby N91242-410029 N/A RSO O848-93 N/A Replacement No Spring w/ Spring Crosby NX3055-0067, N/A RSO 3069-85 N/A Replacement No ( Washers N90982-55-0508, 0496 -

7. Description ofWork:

~ The valve was removed from position 3PSV9226 on MO 93020315 and was reworked under the'ribuild program. The i* ens listed above were replaced and the valve was reassembled, tested and returned to warehouse stock. 4

8. Tests Conducted: N!.A Pressure: N/A Temp: N/A n

_ _._.-_,-_b,,_..,_.-,._,b.___ 3)eneb abset is-  ? and to mrnbar of share b remaremi et en top of eiis farm and (4)sesh sham b henied and deasd by as oumar er Omners emmenes and as a

FORM NIS-2 (back)

9. Remarks : None.

v..  :, w = m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confordstotherules of the ASME Code, Section XI. npuernplumnas Type Code SymbolStamp: N/A Certt6cate ofAuthorizationNo: N/A ExpirationDate: N/A Siped: M b Sunenisine ASME CoderEnrineer Date: 7/2 /95, Owner or Owners Desipec, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and tbc State or Province of California. and employed by A rkwirbt MutualInsurance Comnanv (Factory Mutual Enrineerine Ass'oeistion) of Norwood. Massacbusetts hgve ' the emts described in this Owncts Report dcringtheperiod_ ff//6/94 to _ 7/f 4/G . and state that to the best ofmy knowledge and belief, the Owner has perfon6ed exammations and'taken' corrective measmes described in this Ownefs Report in recordance with the requirements of the ASME Code, Section XI. By sipin8 this certificate, neither the Inspector nor his employer makes any warranty, ayd or implied, concemmg the examinations and corrective measmes described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising frem or connected with thisinspection.

                         ~

Chef 2&>t Commissions /M>2 California laspectorsSipatur15 National Board, State, Province, and Endorsements

                                                                \

Date

                      /
                                   $31986 (l'

m-se; *

           . e \ ;',    .   .u    '
                                           ,,\.   < * ~
                                                                                       ,                      s                       * +

FORM NIS-2 OWNER'S A.wy r. REPORT

                                                                                          .re.asusc         s ooFOR REPAIRS OR REPLACEMENTS
1. Owner: Southem California Edison Company 2244 Walnut Grove Avenue Unit: 2 1 Rosemead,Califomia 91770 MO: 94020429000 f Rspec 019 94
2. Plant: San Onofre Nuclear Generating Station P&ID: 40141D E-4 San Clemente, Califamia 92674-0128  : S2-130b2
3. WorkPerfonnedby:

Southern CalifomiaEdison Company Type Code SymbolStamp: N/A Authorization No: N/A

4. Identification ofSystem: Main Steam ** ^
5. (a) Applicable Construction Code:

ASME Section IR Class 2.1971 Edition. S'73 Addenda. Code Cases Non (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Repaired orReplaced and Replacement Components:

Name of NameOf Manufacturer Repaired, ASME Component Natier.al Other Manufacturer Serial No. Year - Replacedor

  • Code ~

Board No. IdentiScation Buik Replacerres St=- 7_? l' SW Globe Valve Kerotest YesHo FAG 25 3 N/A S2130lMU1257 1981 Replaced l' SW Globe Vahc Kerotest XA21-6 Yes N/A RSO 2-P-147-84 1979 Replacement Yes

7. Description ofWork*
 }          The valve WR2-94-05).      leaked and was scheduled for replacement. Installation was perfonned in accordan I
8. Tests Conducted: System Functional Pressure Test Pressure: 903 psig Temp:H%

1 _ _ m .m _ .._~ r . _.,.. _ _ _ _ _ _ _ _ _ _ _ _ - --- ~~

FORM NIS-2 (b ck)

9. R-arks : None.
                                                            ,,w --
e. _

CERTIFICATE OF COMPLIANCE renlacement conforms We certify that the statements made in the report are correct and this repairorreplacement to the rules of the ASME Code, Section XI. Type Code Symbol Stamp: N/A ExpirationDate: N/A Certificate of Authorizati . No: N/A Date: 8' / / 06 Siped: A Stmervisine ASME Codes Encineer Owner or Owner's Designee, Title CERTIFICAIE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Prersure Vessel Insp . the State or Province of Canfornia. and employed by Arkwrfebt MutualInsurance Comnanv (Factory Mutual ~ EneIneerine Assoelation) of Norwood. Massachusetts pave inspected the components desenkd in this Ouner's Report

                                                                               . and state that to the best of my knowledge and dmingthe period         /A fA96               to M/4/94~

belief, the Owner has performed examinations and'taken corrective measures described in this Owner's Report in accordance with the requirements of the AShE Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implie examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising connected withthis inspection. 4m/)drA Commissions /I42 Califomia National Board, State, Province, and Endorsements Inspector's Sipatur6 Date -pkJ/A. 8 ]C")C)X

- - - - - - ~                                    __               ____

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As n.e-d er a. pi-- . tem A5tE Code Sasaanx! i

    ^   1. Owner: Southern CaliforniaEdison Company                                                                  Unit: 2                                                           I
   /'                        2244 Walnut Grove Avenue                                                                MO:         94020694001 ,94100193000                              )

. h} R-at California 91770 - FCN: F10859M Rspec: 120-94, GEN-139 I

2. Plant: San Onofre Nuclear Generating Stat,.on San Clemente, California 92674-0128 P&IDi 40112A N 5: S2-1204-3
3. WorkPerformedby: Southem California Edison Company Type .: ode SyrnbolStamp: N/A Authorization No: N/A
4. Identification of System: Reactor Coolant Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section IIL Class 1.1971 Edition. S'73 AAA ada Code Cases Mone )

(b) Applicable Edition of Section XI UQized for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Rept. ired or Replaced and Replacement Components: I Repaired. ASME Name of Name Of Manufamirer National Osbar Year Replaced er Code Component Manufacturer Smal No. Board No. Identification Built Replacement Stamped Yes %

8' Tilting Dise Check Anchor / Darling IN 274 N/A S21204MUO74 - Yes Valve 1/2"-13x36' All Nova Machine Heat 16925 N/A RSO 1377 93, N/A Replacement No nread Products SA-453 Gr. 660B 5/8*-11x36' All Nova Machine Heat 22678 N/A RSO 1377-93, N/A Replacement No Bread Products SA-453 Gr. 660B A l/2".13 Heavy Hex Nova Machine Heat 24848 N/A RSO O335-95, N/A Replacement No Q Nuts 5/8* 11 HeavyHex Products Nova Machine Heat 24848 N/A SA-453 Gr. 660B RSO 1377-93, N/A Replacement . No Nuts Products SA-453 Gr.660B

7. Description of Work:

The hinge pin cover studs and nuts were replaced with an altemate material with greater resistance to stress corrosion 1 cracking. Using GEN-139, four 1/2" diameter and four 5/8" diameter studs were cut to the proper size from all thread i material, with the required markmgs being transferred to the cut pieces. He 5/8" diameter studs were cut using MO ' 94100193. A VT-1 examination was performed on the replacement bolting.

Reference:

FCN F10859M 1 i

8. Tests Conducted: System Functional Pressure Test Pres: 643 psig Temp: N/A 1
                                                                                                                                                                                     -1 O  _ =                _.

3)each sheer s-f and $m numba ershese a smearded et en top of es ima, and (4) each sheet s senated and deesd by tw Ones er Owners daugner and Ow A1A.

FORM NIS-2 (back)

9. Remarks : None.

m .m. + . m CERTIFICATE OF COMPLIANCE We cemfy that the statements made in the report are correct and this renlanment conformstotherules of the ASME Code, Section XI. npair orreptument Type Code SymbolStamp: N/A Certifieste ofAuthorization No: N/A Expiration Date: N/A Signed: / Suoervisine ASME Codes Encineer Date: /!9/S T Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid mmmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Cornnanv (Fadorv Mutual Entlecerine Associatlog)pf Norwood. Massacbusetts havp inspected the components desenkd in this Owner's Report during the period /S/fB/G4 to MP/C /C E~ . and state that to the best of my knowledge and belief, the Owner has pedarmcid examinations and talen c6rrective measures desenkd in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Outer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising hem or connected with this ' ection.

                    /As h                             Commissions /Id                          Califomia Inspector's Signature /                                        National Board, State Province, and Endorsements Datebf)O,A.$Q$5
             ;       a 1

O - m.-- W

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As me edwe enm an.fOn AEME Cade $anonXI

1. Outer: Southern Califomia Edison Company Unit: 2 f' 2244 Walnut Grove Avenue MO: 94020697000,94100193000
~ (])                     Rosemead,Califomia 91770                                                                     FCN: F9675M Rspec : 133-94, GEN-139
2. Phnt: San Onofre Nuclear Generating Stat,on San Clemente, California 92674-0128 P&ID: 40113B D-6 N-5: S2-1204-3
3. WorkPerformedby: Southem California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A
4. Identification of System: Safety Injection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1971 Edition. S'73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufacturer National Other Year Replaced er Code Componerg Manufacturer Serial No. Board No. Identif2 cation Buih Replacement Stamped Yes% 12" Tilting Disc Anchor / Darling IN-190 N/A S21204MUO42 1976 - Yes t Check Valve 1 3/4*-10x36* All Vitco,Inc. Ht. Code NBM N/A RSO 0318-94, N/A Replacement No Thread SA-453 Gr. 660B, CCase 1649 3/4*-10 Hensy Hex Nova Machine Heat 13564 N/A RSO 1846-94, N/A Replacement No l

    ,    Nuts                                                                                                          SA-453 Gr. 660B v)
7. Description of Work:

The hinge pin cover studs and nuts were replaced with an ahemate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, eight studs were cut to the proper size from all-thread material, with the , required markings being transferred to the cut pieces. A VT-1 examination was performed on the replacement bolting.

Reference:

FCNF9675M l l l

8. Tests Conducted: System Leakace Pressure Test Pres: 647 psia Temp: N/A

__._._.__m._.,_ _ _ , . - . - . _ _

3) seah shese a nwnbered and tw namnba of sheets a teserM st ow top of cus feein, and (t, sech sheel s sehened and dated by Ow Oe'ner . Owners desense and Gm AUL

a, FORM NIS-2 (b:ck)

9. Remarks : None.

w =_m.. m a.p.n. . m CERTIFICATE OF COh&LIANCE We certify that the statements made in the report are correct and this renlacement conformstotherules of the ASME Code, Section XI. repair erreplacement Type Code Symbol Stamp: N/A Cestificate ofAuthorization No: N/A Expiration Date: N/A SiEned: Owneror' Owner's Designee, Title Sunervisine ASME Codes Encineer Date: [ ' '

                                                                                                                     #J 6 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comnanv (Factorv Mutual                      --

Enrineerine Association) of Norwood. Massachusetts hpve ' ected the components described in this Owner's Repo:t - during the period f // /d7 C to_ A /d 7 A R . and state that to the best ofmy knowledge and belief, the Owner has pf:rforfned examinations andYaken' corrective measures described in this Owner's Report in accordance with the requirements of the AShE Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liab!c in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                     !         /1-s#Af/71 InspectoPs Signature /

Commissions /dlI2_ California National Board, State, Prosince, and Endorsements Date Aur). 9, f995

                      /

Mo: 64:006s7000 l

FORM NIS-2 OWNER'S A.m REPORT w by e.pam FOR REPAIRS OR REPLACEMENTS

                                                                                                                                                                                      .re. Aswa e.e s.w.x:

7'

1. Owner: Southern California Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 94020858001,94100193000 hs R-d California 91770 FCN: F10861M
2. Plant: Rspec 121-94, GEN 139 San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40112D N 5: S2-1204 2
3. WorkPerformedby: Southern California Edison Company fype Code SymbolStamp: N/A AuthorizationNo: N/A
4. Identification ofSystem: Reactor Coolant Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section Ill Class 1.1971 Edition. S*73 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Repared, ASME Nameof Manufacturer Nadonal Other Year Replaced or Component Manufacturer Code Serial No. Board No. Identificanon Buik Replacement Stamped Yes,No 8" Tilting Disc Check Anchor / Darling 1N-229 N/A S21204MUO75 1976 -- Yes Valve 1/2* 13x36" All Nova Machine Heat 16925 N/A RSO 2991-93, RSO N/A Replacement Thread No Products 1377-93, SA-453 Gr. 660B 5/8*-11x36' All Nova Machine Heat 22678 N/A RSO 1377-93, N/A Replacement No y Thread Products SA-453 Gr. 660B (u) 1/2*-13 HeavyHex Nuts Nova Machine Products Heat 24848 N/A RSO O335-95, SA 453 Gr. 660B N/A Replacement No 5/8* 11 HeanHex Nova Machine Heat 24848 N/A RSO 1377-93, N/A Replacement Nuts No Products SA-453 Gr. 660B

7. Description ofWork:

The hinge pin cover studs and nuts were replaced with an alternate material with greater resistance to stress corrosion cracking. Using MO 94100193 and GEN-139, four 5/8" diameter studs were cut to the proper size from all-thread material, with the required markings being transferred to the eut pieces. The four 1/2" diameter studs were cut to the proper size on MO 94020858001. A VT-1 examination was performed on the replacement bolting.

Reference:

FCN F10861M

8. Tests Conducted: System Leakace Pressure Test Pres: 635 67 osia Temp: N/A m t l

v wmr .. e e. e, ro .rn ~ _..dr y 6. =-d n a m = a s to .a n o> =*o .m i e h e.e= =p i. *aad..un x I

3) each shast a menbeed and e. a.nbar efeheet a noorded at Ois kip of ei. Form, and @ each sheet u estaled and ested by the Own. er Owners desense and e. AIA

FORM NIS-2 (bcek)

9. Remarks : None.
v. ~  :, um nmm CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstotherules of the ASME Code, Section XI. repair er reptacement Type Code Spnbol Stamp: N/A Cenificate ofAuthorizationNo: N/A Expiration Date: N/A Siped: M Supervisine ASME Codes Enmneer Owner or Outer's Desipee, Title Date: J'
                                                                                                          /J5          ~

CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwriebt MutualInsurance Commanv (Factorv Mutual Eneineerine Association) of Norwood. Massschusetts have inspected the components described in this Owner's Repon during the pe iod ff//9/B4 to M/C/4M . and state that to the best ofmy knowledge and belief, the Owner has pe(forme'd examinations and t'aken' corrective measures described in this Oster's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng th examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injtuy or propeny damage or a loss of any kind arising from or connected with thisin 'on. [ inspector'sSipature # h Commissions fM2. Califomia National Board, State, Province, and Endorsements Date /)}/A,, A, f9QT

              -- y         <
 ~ ~ - .

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u n.cs.s w e. n of as ASW C.h 5.st.XI a.mswa

1. Owner. Southern Califomia Edison Company Unit: 2
   .m                    2244 Walnut Gmve Avenue                                                 MO: 94021405000 Rosemead, California 91770                                              Rspec 018-94                                            ,

P&ID: 40123A G-6  !

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 N-5: S2-1201 3-10
3. WorkPerformedby: Southern CalifomiaEdison Company Type Code SymbolStamp: N/A Authonzation No: N/A
                                                                                                        *         *                ^
4. Identification of System: Chemical and Volume Control
5. (a) Applicable Construction Code: ASME Section III Class 1.1974 Edition No Addanda Code Case: 1637 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No A AAanda j
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Nameof Nameof Manufacturer ' National Other Year Replaced or Code ce Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 2" Control Valve Fisher Controls 6287963 3754 2HV9204 1979 - Yes - Valve Plug Fisher Controls AA5676-1 N/A RSO 2406-89 1989 Replacement Yes -

7. Description ofWork:
    %       The valve was disassembled for inspection due to seat leakage. The valve plug was replaced. Snubbers S2RC022H008 and H009 were required to be removed to enable valve maintenance and were then remstalled. After installation the snubber -

assemblies were visually examined with satisfactory results. i l i l

8. Tests Conducted: System Leakare Pressure Test Pressure: 2255 osia Temp: 512'F i
      -      ,s .          _ - _ . ~ . ~.. --.am.-
              -~.e.,.,-o,-.-,_.mm....n~,...,----                                                                    .               .                     1

FORM NIS-2 (bick)

9. Remarks : None.

(Appwabie Manu:ur. ars Lea kepara io be anasneef CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reniseement conformstotherules of the ASME Code, Section XI. repair erreplacement O Type code Syrnbol Stamp: N/A Cenificate of Authe ' ti No: N/A Expiration Date: N/A Signed:_ /2 / Simervisine ASME Codes Eneineer Date: [// I Owner or" Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California, and employed by Arkwricht Mutual Insurance Comoanv (Factorv Mutual Enrincerine Association) of Norwood. Massschusetts have inspected the components described in this Outer's Report during the period 5//'7/ 94 to 7/3//75 , and state that to the best ofrny knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ov.mer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desenbed in this Osmer's Report. Funbermore, neither the Inspector nor his employer shall be liabic in any manner for any personal injury or property dr. mage or a loss of any kind arising from or connect th this ins on. / TdGUI u-Inspector's Signature Commissions / 74' Califomia A!/[ National Board, State, Province, and Endorsements Date Glu A, Y L/ V l ua; uwa.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u n==4 w e. % .reasur ca.smu si i .ri

f N
1. Owner: Southern Califomia Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 94031297000

( ~~

    )                       Rosemead, California 91770 Rspec: GEN-112
2. Plant: San Onofre Nuclear Generating Station P&ID: 40124B E-2 San Clemente, California 92674-0128 N-5: S2-1208-5
3. Work Performed by: Southem Califomia Edison Company Type Code Spnbol Stamp: N/A Authorization No: N/A
4. Identification of System: Chemical and Volume Control Expiration Date: N/A S. (a) Applicable Construction Code: AShE Section IIL Class 2.1974 Edition. S74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired orReplaced and Replacement Components:

Namrof Repaired. ASME Name Of Manufacturer National 0 her Component

                                                                                                  .              Year   Replaced or    Ccde Manufacturer           Serial No. Board No.      Identification      Built   Reptacement   Stamped YesNo 1 1/2" x 2' Nozzle        Crosby               N59380-00 00)3        N'A      2PSV9226                1985    Replaced        Yes Tme Relicf Valve i 1/2' x 2" Nozzle        Crosby               N59380-00-0002        N/A      MO 92102143             1977 Replacement       Yes Type Relief Valve Spare
7. Description of Work:

N The valve was replaced due to evidence ofleakage around the upper body flange and body plug. A refurbished sp had previously been reworked using MO 92102143, was used as the replacement valve.

8. Tests Conducted : Svstem Functional Pressure Test Pres :2350 nsie Temp :M

( .

       "" hJ.2%'LWl,. z:W.< C '!.".2'2. 2' 3 M ;a'.*~l.*,:t'~*C* la M *
  • FORM NIS-2 (back)
9. Remarks: None.

4Appmbes Mariuss&*gers Late Kaporta 60 be anadasd/ O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rentacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed- ///M . Supervisine ASME Codes Encineer Date: y [9 5 Ouver or Duner's Desicnee, Title ' CERTIFICATE OF INSP' CTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Compant (Factorv Mutual Eneineerine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 7/7/94 to J/8//S5 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be lia) le in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this ' mspektion. p ettw '. pdi~m Ce::urdiske California lO74f Inspector's Signature ihtional Board, State, Province, and Endorsements Date 1 1 II Mo ' GdC31297000

FORM NIS-2 OWNER'S 4.m REPORT a,ys.p== FOR REPAIRS OR REPLACEMENTS

                                                                                  .re.Asurc s a.nxi
1. Owner: Southern Califamin Edison Company Unit: 2  ;

2244 Walnut Grove Avenue MO: [\ Rosemead, California 91770 94040946000 FCN: F9273M,F9275M

2. Plant: Rspec : GEN-106 R1 San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40111A N-5: S2-1201-3
3. Work Performed by: - Southern California Edison Company Type Code Symbol Stamp: N/A AuthonzationNo: N/A
4. Identification ofSystem: Reactor Coolant Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1980 Edition. S'82 Addenda. Code Cases: None j

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:  !

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesHo Reator Coolant Pump Byron Jackson 701 N-0558 N/A S2120 IMP 001 1977 - Yes Seal Cartridge Bingham. 1714880 3 1172 SO23-CART-22 1986 Replaced Yes Willamette Seal Cartridge Bingham- 1714880-1 1169 SO23-CART 19, 1986 Replacement Yes Willamette Rebuild MO 94050050 0 7. Description of Work: The RCP seal cartridge was replaced with a spare which had been rebuilt in accordance with MO 94050050. and FCNs . F9273M and F9275M. A VT 1 examination was perfonned on the housing assembly capscrews with satisfactory results. removed seal canridge was placed into the rebuild program.

8. Tests Conducted: sys_emi.cakace Pressure Test Pres: 1258 psia Temp:ilD*E i

i I wotT.: s_,. r .h.n. m e. ta .r n =h .t.et, j

                         . ~ m .b.a.nnche.,e    .rm am.e,
                                                     .      anyi
                                                             . . u.ed-.poid.d ..(1).m- .-:in, a si m,c)mrwamm.on
                                                                                                        .~.~          a.new. ..I ovoush a mieu. .epet ' s.

> ~ FORM NIS-2 (b:ck) ' i

9. Remarks: None. ,

w w -2co,a % .w. % CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are conect and this renlacement confonnstotherules of the ASME Code, Section XI. repair er nptxement Type Code Symbol Stamp: *N/A Certificate of Autho tion No: N/A Expiration Date: N/A Siped: Suoervisine ASME Codes Encineer Date: 5'///95 Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Californla. and employed by A rkwricht MutualInsurance Comnanv &setorv Mutual I Encineerine during the period Association) E//b/VS of Norwood. to Massschusetts 7/3 Jy// 95vg inspected the components described in this Owne

                                                                                       . and state that to the best of my knowledge and belief, the Owner has perfonned examinations and taken corrective measures desented in this Oumer's Report in accordance with the requirements of the ASMS Code, Section XI.

By signing this certificate, neither the Inspector nor his emplo)er makes any wananty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connect with thisin ecti O01AXUL W M- l57b C Inspector's Sipature Commissions u'~;* lI National Board, State, Province, and Endorsements ' 1 Date 8///95 I l I l Mo; 940emm

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS unon dbye= enm nsvs. Asur ca s=m=x: I 73 1. Owner: Southern CaliforniaEdison Company Unit: 2 l ( '

    )                        2244 Walnut Grove Avenue                                                                        MO: 94041244001                                                       )

Rosemead, California 91770 FCN: F9274M, F9276M i Rspec: GEN-106 R1

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40111A N-5: S2 1201-3
3. WorkPerformedby: Southern California Ed%on Omnpany Type Code SymbolStamp: N/A Authorization No: N/A
4. Identification of System: Reactor Coolant ExpirationDate: N/A S. (a) Applicable Construction Code: ASME Section III. Class 1.1980 Edition. S'82 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced er Code C- Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesNo Reactor Coolant Byron Jackson 701-N-0560 N/A S2120lMP003 1978 - Yes ) Pump Seal Cartridge Bingham- 1714880-2 1171 SO23-CART-21 1986 Replaced Yes Willamette , 1 Seal Cartridge Bingham- 1659057-2 1173 SO23-CART-23, 1986 Replacement Yes  ; Willamette Rebuild MO j Q 93120392  ! d ,

7. Description ofWork:

The RCP seal cartridge was replaced with a spare which had been rebuilt in accordance with MO 93120392, and FCNs I F9274M and F9276M. A VT-1 exammation was performed on the housing assembly capscrews with satisfactory results. The , removed seal cartridge was plad into the rebuild program. l l i I S. Tests Condueled: System Leakace Pressure Test Pres: 2258 nsis Temp: iLQ'E Q.) NOTI. sigykenental abeets a $w lans of hsg sketches or drawmes muy be mind prended (1) em u 8 t/2 m a l a n, Q) sderasson am leems I throach 4 on tus seport a su:baded on och shee(

3) each sheet a numbered and the surnba of sheets a rumorded at the by of dus forrg and (4) each shees a subaled and deled by the Owner or Owners ess6nes and the AR

FORM NIS-2 (back)

9. Remarks : None.

w-- -

                                                              -m . t.. #.       ....
                                                                      ~

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reefacement conformstotherules of the ASME Code, Section XI. repair er replacement Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped: Ms Sunervisinc ASME Codes Encineer Oumer or Owner's Desipee, Title Date: 1/b5 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orProvince of California. and employed by Arkwricht MutualInsuranee Comoanv (Factorv Mutual En cineerine A ssociation) of Nornood. Massachusetts have inspected the components described in this Owner's Repon during the penod .:2//i/95 to 7/3//76 . and state that to the best ofmy knowledge and belief, the Owter has performed examinations and taken corrective measures described in this Outer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conce examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer hall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connec hith this inspect'on. itarr . Inspector's Sipature Commissions /EIIcalifornia National Board, State. Province, and Endorsements I Date _ e Y

                                                                                                                                                      ......._l FORM NIS-2 OWNER'S REPORT FOR REPMRS OR REPLACEMENTS u not a i,, n e--      .t n. ma ce s.e. x
         )                                                                                                Sheet 1 of 1
1. Owner: Southern California Edison Company Unit: 2 2244 Walnut Grove Avisue, Sn.emead, CA 91770 MO: 94050237 FCN: F9395M
2. ' Plant: San Onofm Nuclear Generating Station RS: 026-94 P.O. Box 128, San Ocmente, CA 92674-0128 P&ID: 40141G (H-4)
                                                                   .                                      N.S:         S2-1301-2
3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A
4. Identification of System: Steam Authorization No: N/A Expiration Date: N/A S. (a) Applicable Construction Code: ASME Section III, Cass 2,1974 Edition, S75 Addenda (Valn),

1974 Edition, S74 (Tubing and Fittings) Code Cases: None (b) Applicable Edidon of Section XI Utilized for Repairs or Replacements: 1989 Edition, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer Nadenal Other Year Replaced, or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 3/8" Isolation Valve Gould 23684 N/A Reference 1979 Replaced Yes 2PI8204M 3/8" Isolation Valve Anderson N89280 N/A RSO 1307-93 1983 Replacement Yes Greenwood 3/8" Isolation Valve Gould 24034 N/A Reference 1979 Replaced Yes 2 PSIA 204 (nb) 3/8" Isolation Valve Anderson Greenwood N89266 N/A RSO 1307-93 1983 Replacement Yes 3/8" Obow (2) Parker Hannifin Hr. Code IBAW N/A RSO 2382-93 N/A Replacement No SA 182, Gr 316

                                                                                                                                                               ]

3/8" x .065" Iubing Sandvik Steel Ht. Code MSS 18 N/A R50 2359-93 N/A Replacement No SA-213, Gr 316 I

7. Description of Work:

j The isolation valves to 2P18204M and 2PS12204 were replaced along with associated tubing and tube fittings. Installation was l performed in accordance with FCN F9395M. Gould valves were replaced with Anderson Greenwood valves as allowed per j SEE 94-0072. l

8. Tests Conducted: 53 stem Izakage [ ] System Functional [X] System Inservice [ ] Hydrostatic [ ] Pneumatic l ] Other [ ]

Pressure: 2450 psig Temp: N/A A l

   \.))

Note: Supplemental sheets in the form oflists, sketches, or drawings may be used provided (1) size is 8 y in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form, and (4) each sheet is initialed and dated by the Owner or Owner's designee and the AIA.

4 FORM NIS-2 (bcck) 9 Remarks:

                                 %e replacement valves were certified to 1983 Edidon, S'85 Addenda. Reconciliation CR 89-003 applies.

(Applicable Manufacturer's Data Reports to be attached) CERTIFICATE OF COMPLIANCE i We cenify that the statements made in the report are correct and this reclamment conforms to the rules of the ASME Code, Section XI. T)pe Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed:  ! 8/h .Supersisine ASME Codes Engineer Date: .19 Owner or Owrier's Designet, Tide ' CERTIFICATE OF INSPEC110N I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors vid the State or Province of California. and employed by Arkwright Mutual Insuranm Company (Factory Mutual Enginer5 int Assochtjgp] of Norwood. Massachte.erts have ins ed a com nents desenbed in this Owners Repon during the period 6VM/W to _ _ .3 ._

                                                     . and state that to the best of my knowledge and belief, the Owner 7,as performed' examinations and faken corrective measures described in this Owners Report in accordance with the regrerernen the ASME Code, Section XI.

By signing this cenificate, neither the inspector nor his employer makes any warranty, expressed or implied, cor cerning the examinations and corrective measures described in this owners Report. Furthermore, neither the Inspector nor sis employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connec ed with this inspection.

                             ~ mde Inspectofs Signature /              '

Commissions /Y/S California (National Board, State Province, and Endomments } Date

           /

A E ' 19kC L een. 9

1 l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u n ered by ae %== ora. Asus ce4.ss =x Ekseti en i fm 1. Owner: Southem Califomia Edison Company Unit: 2 ) (U )' 2244 Walnut Grove Avenue MO: 94050508001 Rosemead, California 91770 Rspec 006-95,EREF-0179  ; P&ID: 40ll2C D-5

2. Plant: San Onofre Nuclear Generating Statim San Clemente, Califamia 92674-0128 N-5-* S2 1204-34
3. WorkPerformedby: Southern CalifomiaEdison Company T3pe Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Boric Acid Mix and Storage
                                                                                                                       "*          *                   ^
5. (a) Applicable Constmetion Code: ASME Section 111. Class 2.1974 Edition. No Addenda. Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Narne Of Manufacturer National 00wr Year Replaced or Code Component Manufacturer Serial No. Board No. Idersification Built Replacemset Stamped YesNo 2" Y-type Globe Target Rock 74R-002-10 N/A 2HV9324 1977 Repaired - Yes Valve

7. Description of Work:

[

  • The valve was disassembled for inspection due to packing leakage. This required the removal of the bWy-to-bonnet seal weld. The valve internals were cleaned and remstalled. The body-to-bonnetjoint was the s seal-welded in . ecordance with  ;

weld record WR2 95105.

8. Tests Conducted: System Functional Pressure Test Pressure: 151I nsie Temp: E!A O

_ s _ _ ._ _ . _ . . _ . _ . _ _ .. , _ .. _ .... _ _ _ _ ,. - d _ m _ _ 3)and sheet is numband and ou nenher of sheets a socorded et On Inp of tw Swm, and (4) eneb shes a suenlud and deed by the Owner er Ouests deugnee mid Ow AtA.

FORM NIS-2 (b:ck)

9. Remarks: None.

mm= uwe m.m.p.n.w .rm CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are con ect and this of the ASME Code, Section XI. unak conformstotherules repair or reptuement Type Code S 3 7nbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: [ Sunenisinc ASME codes Encineer Date: [/ 6 OwnerorOwner'sDesignee Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoihr and Pressure Ves the State or Province of California. and employed by Ark,vright Mutual Insurance Comnany (Factorv Mutual Enclneerinc during the period A ssociation) J////95 of Nomood. to 7/3y9.5Massschusetts have inspected the components desenbed belief, the Owner has performed examinations and taken corrective measures describ accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any wa: examinations and corrective measures described in this Owner's Repon. Furthennore, neither th conne ed withshall employer be liable this inspe ion. in any manner for any personal injury or property damage or a loss of any kin h h MN Inspector's Signature

                                        'n                Commissions                                 Califomia A![

National Board, State, Province, and Endorsements Date Etd $ lYVS V .3 O Mo: 94050505001 W \

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.n e n.r== n..tm.AsMECoe M a.as.u ,

 ,\

I. Owner: Southern CaliforniaEdison Company Unit: 2 l [d 2244 Walnut Grove Avenue Rosemead, California 91770 MO: 94050922000 Rspec EREF-0173

                                                          .                            P&ID: 40111B G-5                                      l
2. Plant: San Onofre Nuclear Generating Station N-5*- S2-1201-2  !

San Clemente, California 92674-0128 j

3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A j AuthonzationNo: N/A l
4. Identification of System: Reactor Coolant
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1974 Edition. No AMavin (Valvel S'74 AMavla (Inlet Boltind Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repausd. ASME Name of Name Of Manufacturer National Other Year Replaced or Code ce Manufacturer Serial No. Board No. Identifxation Built Rept=mant Stamped Yes/No 6*x8" Pressurizer Dresser BSO3212 N/A 2PSV0200 1978 Replaced Yes , Safety Valve 6"x8" Pressunzer Dresser BSO3209 N/A RSO O341-94, 1978 Replacement Yes safety Valve Tested Spare , 2*-8x141/2" Inlet CardinalIndustrial Ht. Code B4 N/A RSO 3073-91, N/A Replacement No [ Studs (3) Products SA 193 B7 2*-8x141/2* Inlet CardinalIndustrial Ht. Code B4 N/A RSO 2982-91, N/A Replacement No Studs (2) Products SA 193 B7 > Inlet Nuts (8/3) Nova Machine K4T & K7M N/A RSO 2060-93, N/A Replacement No SA 194 Gr. 7 Inlet Nuts (4) Nova Machine K4H N/A RSO 1415-93, N/A Replacement No SA 194 Gr.7 , Inlet Nuts (l) Nova K7M N/A RSO l869-93, N/A Replacement No ' MachineNova SA-194 Gr. 7 Machine

7. Description ofWork:

The pressunzer safety valve was replaced as a scheduled maintenance action. The inlet flange bolting was VT-1 examined and replaced based on the examination results. The removed valve was placed into the rebuild program.

8. Tests Conducted: System Leakace Pressure Test Pressure: 2258 osia Temp: 510*F l I

O 1

w. ===:====== = :=e.==- 1 1

FORM NIS-2 (back)

9. Remarks : None.

v m mca. u. u n we u sa,a > CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair er replacemmt T3 pe Code SpnbolStamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: Sunenisine ASME Codes Eneineer Date: # 6 Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vesse! Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insuranee Comoanv (Factorv Mutual Encineerine Anociation) of Norwood. Massachusetts have inspected the components described in this Owner's Repon during the period // / O / '/3 to '7/5//75 . and state that to the best ofmy knowledge and belief, the Owner has perforined examinations and taken conective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employ shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or conn t d with this ~ specti . . G/E4 . Inspector's Signature Commissions  ! California f National Board, State, Province, and Endorsements Date (N , .55

    - n

. a__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS - 4.ame.mmm wn.asmcoms wm

1. Owner: Southem California Edison Company Unit: 2
     ./m 2244 Walnut Grove Avenue                                                                                          MO: 94050942000 95030863000 95031529001
   ' b                                                  Rosemead, California 91770 Rspec 073 94,100-95,EREF-0173
2. Plant: San Onofre Nuclear Generating Station P&ID: 40111B G-5 San Clemente, Califorma 92674-0128 N-5: S2-1201-2
3. Work Performed by: Southem Cahi= FAison Company Type Code SymbolStamp: N/A Authorization No: N/A
4. Identification of System: Reactor Coolant ae A
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1974 Edition. No Addenda (Valvel S'74 A AAman (Inigt.

Boltind Code Cases: None

   .                                        (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer National Other Year Replaced or Code Componera Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yan/No 6"x8* Pressunzer Dresser BUO6253 N/A 2PSV0201 1980 Replaced Yes Safety Valve 6*x8' Pressurg.cc Da BUO6254 N/A RSO O341-94, 1980 Replacement Yes Safety Valve Tested Spare Repaired 2*-8x141/2" Inlet CardinalIndustrial Ht Code B4 N/A RSO 3073-91, N/A Replacement No [ Studs (6) Products SA-193 B7 Inlet Nuts (16) Nova Machine T7208, K4H N/A RSO 1415 93, N/A Replacement No Products SA 194 Gr. 7

7. Description of Work:

The pressunzer safety valve was replaced as a scheduled maintenance action. He inlet flange bolting was VT-1 exammed and replaced based on the examination results. The removed valve was placed into the rebuild program. Gouges and marks were noted on the inlet seating surface of the replacement valve and the gasket sealing surface of the flange as documented in NCRs 95030149 and 95030078. The gasket sealing surface of the flange was machined and PT examined on MO 95030863. The valve seating surface was machined and PT examined on MO 95031529001. -

8. Tests Conducted: System leaksce Pressure Test Pressure: 2258 tisia Ternp: 510*F l l

hhm W 9w a 8w W Ou s

FORM NIS-2 (b:ck)

9. Remarks: 'None.
                                                   = ==x.,mamm. m .p.n . . m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renair and renlacement conforms to the rules of the ASME Code, Section XI.                                            repair er replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A                      Expiration Date: N/A Signed:                                     Stmervising ASME Codes Encineer             Date:         JP!/IPf Owner or 6wner's Designee, Title                                                             //

CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwriebt Mutual Insurance Comnanv (Factorv Mutual Encineerine during the period Assoefation)p/7/75f

                              //                  toNorwood.

8///T5 Massachusetts

                                                                               . and statehave that to inspected the best of my the components knowledge and  described in belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his empi er shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or conn ed with this ' ti OOtocut . ' a4b Commissions IN Califemia National Board, State, Province, and Endorsements [ Inspector's Signature Dae (Let I. ! W .. _ h Mo: 9405094 m 9'

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS um aw m .<= maces m m awi 1.- Owner: . Southern Califomia Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 94051480000 (O/ Rosemead,Califamia 91770 Rspec EREF-0185 P&ID: 40141D

2. Plant: San Onofre Nuclear Generating Station N-5 *- S2-1301-1 San Clemente, Califamia 92674-0128
3. WorkPerformedby: Southem CalifomiaEdison Company Type Code SymbolStamp: N/A AuthorizationNo: N/A
                                                                                               *         *               ^
4. Identification of System: Main Steam
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 Addenda. Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Narne of Manufacturer National Other Year Replaced er Code Component Manufaciunr Seria!No. Board No. Identification Built Replacement Stamped Ym% 6"x10" Main Steam Crosby Valve & N58737-00-0037 N/A 2PSV8401 1984 Replaced Yes Safej Valve Gage t'"x10" Main Steam Crosby Valve & N58737-01-0028 N/A Rebuild MO 1977 Replacement Yes Safety Valve Gage 93110758 Inlet Nuts (12) Nova Machine Ht. Code K8H N/A RSO 1373 93, N/A Replacement No 1 Products SA 194 Gr 7 V , 1

7. Description of Work:

The main steam safety valve was replaced as a scheduled preventative maintenance action with a spare valve which had been j retumed to the vendor for rework and flexi-disc modification. A new valve nameplate was created by Crosby which altered the

                                                                                                                                             )

serial number from N58737-00-0028 to N58737-01-0028 to show that the flexi-disc modification had been completed. The i inlet nuts were also replaced. The removed valve was placed into the rebuild program. I l i

8. Tests Conducted: System Functional Pressure Test Pressure: 904 psig Temp: N/6 0 -
            =====:====== =.. o===-

FORM NIS-2 (b:ck)

9. Remarks : None.
                                                   =        wm,n aam ., %

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonnstotherules of the ASME Code, Section XI. repair er reptuement Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped: / Sunenisine ASME Codes Encineer Date: 95 Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Comnanv (Factory Mutual Eneineerine Association) of Norwood. Massachusetts 1; ave inspected the components described in this Owner's Report duringthe period 9/fA/44 to7/3fAW . and state that to the best of my knowledge and belief, the Owner has perforded examinations and'taken corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or , connected with this ' tion. [ Ard&>t Inspecto(s Sipature /

                                              ~

Commissions /MM California National Board, State, Province, and Endorsements Date A Al /$9[

          ,#     (/N /

4 9 id

FORM NIS-2 OWNER'S REPORT FOR un.,-wwe rre REPAIRS OR REPLACEMENTS stumusca,- m sas 1, Owner: Southern California Edison Company Unit: 2 [ ,) 2244 Walnut Grove Avenue MO: 94051485000 .V Rosemead,Califomia 91770 Rspec: EREF-0186

2. Plant: P&lD: 40141D San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 N-5
  • S2-1301-1
3. WorkPerfonnedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A Authorization No: N/A
4. IdentificationofSystem: MainSteam
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S*74 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No AhAm
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared, ASME Name of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Seria! No. Board No. Identification Built Replacement Stamped Yes% 6" x 10" Main Steam Crosby Valve & N58737-00-0020 N/A 2PSV8402 1977 Replaced Yes Safety Valve Gage 6" x 10" Main Steam Crosby Valve & N58737-010029 N/A RebuildMO 1977 Replacement Yes - Safety Valve Gage 93110744 Inlet Nuts (1) Nova Machine Ht Code U6U N/A RSO 1779-94, N/A Replacement No [, Products SA-194 Gr 7, (, CR-2001-93 Inlet Nuts (11) Nova Machine K8H N/A RSO 1373-93, N/A Replacement No Products SA-194 Gr. 7

7. Description of Work:

The main steam safety valve was replaced as a scheduled preventative main:enance action with a spare valve which had been , returned to the vendor for rework and flexi-disc modification. A new valve nameplate was created by Crosby which altered the serial number from N58737-00-0029 to N58737-01-0029 to show that the flexi-disc modification had been completed. The l inlet nuts were also replaced. The removed valve was placed into the rebuild program. { l l l l

8. Tests Conducted: System Functional Pressu're Test Pressure: 204_ pig Temp: E!A r l w.==.===w.=====;== ==-
                                  -                                                                                                1 FORM NIS-2 (baek)                                                        l
9. Remarks:

CR 2001c93 reconciles the replacement nuts from RSO 1779-94,which were certi5ed to ASME III .2,1989

           .             Edition, No Addenda.

v.- u a.~,,u,, w u-1 CERTIflCATE OF COMPLIANCE l We certify that the statements made in the report are correct and this renlacement conformstotherules of the ASME Code, Section XI. repair orrep1=ama Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A ?- Siped: / // Sunervisine ASME Codes Eneineer Owner or Owner's Desipee, Title Date: 4!9 '5 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comnanv (Factory Mutual Incineerine Anociation) of Norwood. Massachusetts h ve inspected the components described in this Owner's Repor during the period .9//A/M tog /W- . and state that to the best ofmy knowledge and belief, the Owner has perforrried examinations an6takert'co:rective measures de cribed in this Owner's Report in accordance with the requirements of the AShE Code, Section XI. By siping this certificate, neither the Inspector nor his employer makes ag am W, expressed or implied, concerning examinations and corrxtive measures described in this Owner's Report. Ftn Nn .se, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ~ 'on. A/ldfr>r ~ Commissions /Idd Califomia Inspector's Sipature / National Board, State, Prosince, and Endenements Date.. 2 /13 f f.Q W

              /       W        '

O MO: 540$1465000

                                                   ..                                                                              l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As n,.ed w as %.f on ASME Coe $semM [] \m/

1. Owner: Southern Califomia Edison Company 2244 Walnut Grove Avenue Unit: 2 MO: 94051486002 95030474000 Rosemead, California 91770 FCN: F10935M,F10937M Rspec : 055-95 R1
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40123B C-6 N-5: S2-1208-4
3. WorkPerformedby: Southern California Edison Compxny Type Code SytnbolStamp: N/A Authorization No: N/A
4. Identification of System: Chemical and Volume Control Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. No Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer Naticeal O her Year Replaced or Code Component Manufacturer SerialNo. Board No. Identification Built Replaatnent Stamped Yes/No Heat Exchanger Ametek 78826 10781 S21208ME062 1977 - Yes l' Nickle Plated Nuts B&G Mfg. Ht Code 4AD N/A RSO 4666-86, N/A Replacement No (10) SA-194 2H, CR-3001-94 Nickel Plated Studs B&G Mfg. Heat 88319 N/A RSO 4666-86, N/A Replacement No p) l, (5) SA-193 B7, CR-2001-93 Studs (8) Nova Machine 94170009 N/A RSO 2276-93, N/A Replacement No Products SA193 B7, CR-2001-93 Studs (7) Nova Machme 8090323 N/A RSO 2064-93, N/A Replacement No Products SA193 B7, CR-2001-93 Studs (8) CardinalIndustrial Ht Code G2 N/A RSO 0763-93, N/A Replacement No Products SA193 B7, CR-2001-93

7. Description of Work:

The heat exchanger channel cover studs showed evidence of corrosion as described in NCR 95030046. "Ihe corroded studs were replaced. Five of the replacement studs were nicide plated and were placed in the bottom positions of the channel cover joint, their associated nuts were also replaced with nickle plated nuts.

Reference:

NCR 95030046, FCNs F10935M, F10937M

8. Tests Conducted: System Inservice Pressure Test Pres: 320 psig Temp: Na

( v 3 m and om a abw s a se=rdadYou tar of [ n e and [ om edesenseab An

FORM NIS-2 (baek) { 9. Remarks : l

           )

ASMEIII-2,1983-S'85 Addenda. CR-3001-94 ASME III 2,1983-S'85 Addenda. n aand reconciles e o { y i _.,, m % w . , i

         '                                                                    CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this of the ASME Code, Section XI.                                               replacement conformstotherules repair <<reptucant i

Type Code SymbolStamp: N/A CenificateofAuthorizati No: N/A ExpirationDate: N/A Siped:_ // Owner or Oher's Desipee, - Sunervisine Title ASME Codes Encineer Date: # ~ CERTIFICATE OFINSPECTION the State or Province ofCalifornla. andomoanv Encineerine Association)pf Norwood. Mattachusetts h ve ~ employed spectorsby (Factory Mutual and Arkwri9ht Mu during the period _ J/7/9S' to 8/8 ted the components desenkd in this Owner's Repon accordance with the requirements of the ASME wner'sCode, Reportin Section XI. belief,th By siping this cenificate, neither the Inspector nor , phis employer makes any warranty u M examinations and corrective measures described in this Owner's employ , Report. mplied, concerning pectornorhis the Funhermore neith

                  . conn edwis  hall be liable in an manner for any personal injury or property s ng from or damafe or a loss of a 4

Men fS74 Inspector's Sipature ~ Commissions __ National Board, State, Province, and Endorsements c iiromia A/ i42f 7, l$?$ i 1* h Mo: 640514860c2

                                                                     ~

FORM MS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.a ,-anya.r <umac d.s axi so o.o m 1. Owner: Southern California Edison Company Unit: 2

 /                             2244 Walnut Grow Avenue                                                          MO:

(-)> Rosemead, California 91770 94051487000 Rspec EREF-0188 P&ID: 40141D

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califorma 92674-0128 N-5: S2-1301-1
3. WorkPerformedby: Southem CalifomiaEdison Company Type Code S3 mbol Stamp: N/A Authonzation No: N/A
4. Identification of System: Main Steam WradonDate: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. S'74 Addenda. Code Cases None

. (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manafacturer National Other Year Replaced or Code C.ompceent Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes.Wo 6' x 10" Main Steam Crosby Valve & N58737-00-0004 N/A 2PSV8404 1976 Replaced Yes Safety Valve Gage 6" x 10' Main Steam Crosby Valve & N58737-01-0025 N/A Tested Spare, 1977 Replacement Yes Safety Valve Gage Rebuild MO 93110750

 /]

(j Inlet Nuts (12) Nova Machine Products Ht Code U6U N/A RSO 1779-94, SA-194 Gr 7, N/A Replacca.:nt No CR-2001-93

7. Description of Work:

The main steam safety valve was replaced as a scheduled preventative maintenance action with a spare valve which had been retumed to the vendor for rework and flexi-disc modification. A new valve nameplate was created by Crosby which altered the serial number from N58737-00-0025 to N58737-01-0025 to show that the flexi-disc modification had been completed. The inlet nuts were also replaced. The removed valve was placed into the rebuild program.

8. Tests Conducted: System Functional Pressure Test Pressure: 904 psic Temp: N/A
  /~'N\                                                                                                                                                                               ,

t O

        ,, ort

_ w - <w.- . ,. o. .a d.d m . m u ., m r.n

  • n.,,. i
                                                                                                                                      . . - . -- 4
3) each sheet e n nbared and O. number of sheets a sesorded al ou icy of aus form, and (4) and sheet s eunnled and daind by te Oumar er Oumer's d.agnse and es AIA.

FORM NIS-2 (b:ck)

9. Remarks: CR-2001 93 reconciles the replacement nuts, which were certified to ASME III-2,1989 Edition, No Addenda.

w- -. u upon. . .n.a.,e CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are con ect and this replacement conformstotherules of the ASME Code, Section XI. repairor reptuement Type Code Spnbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped: M b Suoervisine ASME Codes Encineer Date: I Owner or Osmer's Desipee, Title 1 CERTIFICATE OFINSPECTION ' i I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Irgectors and the State or Province of California. and employed by Arknticht Mutual Insurance Company (Factory Mutual Encineerine Association)pf Norwood. Massachusetts haye inped the components described in this Owner's Report during the period . 4//4,/C42' to ':f/3f/G$ . and state that to the best ofmy knowledge and i i belief, the Owner has pe'rforme$ examinations asitaker(corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the l examinations and corrective measures described in this Owner's Report. huthermore, neither the Inspector nor his  ! employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or l connected with this in tion.

                      ,    . f/)psh                        Commissions          /Id2                   California Inspector'sSipature /                                         National Board, State, Prosince, and Endorsements Date          M3f YW V       U^

Mo; 94051487000

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As agne.4 by e. en-== . rem AshiE coh e-a m f Shea a of a

1. Owner: Southern California Edison Company Unit: 2 O 2244 Walnut Grove Avenue MO: 94051488000
 '(                      Rosemead,Califomia 91770                                                        Rspec: EREF-0190 P&ID: 40141D
2. Plant: San Onofre Nucleat Generating Station San Clemente, Califomia 92674-0128 N-5: S2-1301-1
3. WorkPerformedby: Southern Califomia Edison Company Type Code SymbolStamp: N/A AuthonzationNo: N/A
4. Identification of System: Main Steam i

S. (a) Applicable Constnaction Code: ASME Section IIL Class 2.1974 Edition. S'74 AAA-nA= Code C==**: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repassd, ASME  ! Nameof NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Bmit Replacement Stamped Yes/No 6* x 10" Main Steam Crosby Valve & N58737-01-0001 N/A 2PSV8406 1976 Replaced Yes Safety Valve Gage 6" x 10" Main Steam Crosby Valve & N58737-01-0022 N/A Tested Spcre, 1977 Replacement Yes Safety Valve Gage Rebuild MO 93110747 O Inlet Nuts (12) Nova Machine Ht Code U6U N/A RSO 1779-94 N/A Replacement No. Products SA 194 Gr 7, ' CR 200193 i

7. Desciiption of Work:

The main steam safety valve was replaced as a scheduled preventative :naintenance action with a spare valve which had been , retumed to the vendor for rework and flexi-disc modification. A new valve nameplate was ercated by Crosby which altered the  ; serial number from N58737-00-0022 to N58737-01-0022 to show that the flexi-disc modification had been completed. The , inlet nuts were also replaced. The removed valve was placed into the rebuild pmgram. I i l l l l

8. Tests Conducted: System Functional Pressure Test Pressure: 904 psic Temp: M l
                     -              . - . w - ,. - .                       - ..             .. - - . - .                      h.     - .             . -
3) each sheet u menbeed and Om number of sheen s sauceded a de top of tus fann. and (4)each sheet a sunded sid deed by tu Done or Owners dangner and the A1A.

l

FORM NIS-2 (b:ck)

9. Remarks : CR 2001-93 reconciles the replacement nuts, which were certified to ASME III-2,1989 Edition, No Addenda.
n. =.r, u= % a ,e CERTIFICATE OF COMPLIANCE We certify that the statements made in the repoit are correct and this replacement conformstotherules of the ASME Code, Section XI. repair erreplacement Type Code Symbol Stamp: N/A Certificate ofAuthorizationNo: N/A Expiration Date: N/A Siped: /

Owner or Osmer's Desipee, Title Sunervisine ASME Codes Ene ngg Date: 7 9[96 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comnanv (Factorv Mutual Enclneerine Anociatior0 of Norwood. Massachusetts have inspected the e ponents t'escribed in this Owner's Report during the period 9 ///W'G 4 to *7/5f/M . and stu: that to the best ofmy knowledge and belief, the Owner has performed examinations and takeri corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ' 'on. f J}/ M 2A m InspectoriSignature #

                                                  ~

Commissions lkf5$ Califomia National Board, State, Province, and Endorsements Date .e59S W r u' i l Mo: 9405148a000 i

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. m.,ded e rn= rnm m..f am ASME Code sacemXI sb.maeri
   .3       1. Owner: - Southern Califomia Edtson Company                                                                  Unit: 2
 /    )                        2244 Walnut C-rove Avenue                                                                   MO:          94051489000 V                             Rosemead, California 91770 Rspec EREF-0191 P&ID: 40141D
2. Plant: San Onofre Nuclear Generating Statim p3
  • San Clemente, California 92674-0128 S2-1301-1
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A
4. Identification of System: Main Steaun
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition S*74 Addends. Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1289 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared, ASME Name of Nameof Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Starnped Yes/No 6' x 10" Main Steam Crosby Valve & N58737-00-0007 N/A 2PSV8407 1976 Replaced Yes Safety Valve Gage ' 6* x 10" Main Steam Crosby Valve & N58737-01-0032 N/A Tested Spare, 1977 Replacement Yes Safety Valve Gage Rebuild MO l 93110752 Inlet Nuts (12) Nova Machme Ht Code U6U N/A RSO 1779-94, N/A Replacement No [VD Products SA 194 Gr.7, i I CR-2001-93 l

7. Description of Work:

The main steam safety valve was replaced as a scheduled preventative maintenance action with a spare valve which had been returned to the vendor for rework and flexi-disc modi 5 cation. A new valve nameplate was created by Crosby which altered the serial number from N58737-00-0032 to N58737-01-0032 to show that the flexi-disc modification had been completed. The inlet nuts were also replaced. The removed valve was placed into the rebuild program.

8. Tests Conducted: System Functional Pressure Test Pressure: 904 vsic Temp: N/.A p/

C

  • NOTE f shoes si$m form arbA skmchua.er drawmg5 NWy be used picWDdad (I) Mar 5 I M R 3 $) R.Q) ' E hems I $UOugh 6 On Ous Deport B Wlduded en EGGb Shed.
3) and shaus e awnbared and tu misaber of sheet u essarded at em top of ess fann, and (4) and sheet is sunnled and dated by en Owns or Owners daugnes and em AUL

l FORM NIS-2 (b::ck)  :

9. Remarks: i' CR-2001 93 reccociles the replacement nuts, which were certified to ASME III-2,1989 Edition, No Addenda.

vc= , m -. . w, 3 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rentacement conformstotherules of the ASME Code, Section XI. repairerreplacement Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A EnirationDate: N/A Signed: M Supersisine ASME codes Enrlmu Date: 9 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors an the State or Province of California. and employed by A rkwricht MutualInsurance Comoanv (Factory Mutual Encineerine during the period Associatiop./)f4/G#of 6 to Norwood. 7/3ff.W Massachusetts have inspected the components des

                                                                            . and state that to the best ofmy knowledge and belief, the Owner has performe'd examinations and takeri corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concer examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ~ tion. k MAder _ Commissions /W6:2 Califomia Inspector's Signature ' National Board, State, Province, and Endorsements Date />I4 e T[ f9.9f" W

           /~ W\          '

e

 .      b

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS uamur .eu m a c.s - = Shen 4 et t ,.~ 1. Owner: . Southern Califomia Edison Company Unit: 2 /\ 2244 Walnut Grove Avenue O ' Rosemead, California 91770 MO: 94051492000 Rspec. EREF-0191 P&ID: 40141D

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1301 2
3. WorkPerformedby: Southern Califomia Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identification of System: Main Steam  :
5. (a) Applicable Construction Code: ASME Section III Class 2.1974 Edition. S'74 AAAmda Code Cases: None  :

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

I Repared. ASME Name of Name of Manufacturer National Other Year Replaced or ce Code Manufacturer Serial No. Board No. Idernification Built Repisonment Stamped Yes/No 6* x 10" Main Steam Crosby Valve & N58737-00-0038 N/A 2PSV8416 1984 Replaced Yes Safety Valve Gage ' 6' x 10" Main Steam Crosby Valve & N58737-010033 N/A Tested Spare, 1977 Replacement Yes Safety Valve Gage Rebuild MO - 93110746 fi V Inlet Nuts (12) Nova Machine Products Ht Code U6U N/A RSO 1779-94, SA-194 Gr. 7, N/A Replacement No i CR-2001-93 i

7. Description of Work:

The main stearn safety valve was replaced as a scheduled preventative maintenance action with a spare valve which had been returned to the vendor for rework and flexi-disc modification. A new valve nameplate was created by Crosby which altered the  ! serial number from N58737-00-0033 to N58737-01 0033 to show that the flexi-disc modification had been completed. The inlet nuts were also replaced. The removed valve was placed into the rebuild program. , i r

8. Tests Conducted: System Functional Pressure Test Pressure: 904 t>sg Temp: b_i/A ,

O

        =.=.==. =e==== _ =:= ==-

i l

                                                                                                                                  ]

FORM NIS-2 (b:ck)

9. Remarks : CR-2001 93 reconciles the replacement nuts, which were certified to ASME III-2,1989 Edition, No Addenda.
v. ,,.... ~,w - , m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstotherules
cf the ASME Code, Section XI. upair or replacment Type Code SymbolStamp
N/A Cenificate ofAuthorization No: N/A ExpirationDate: N/A Siped- Sunervisine ASME Codes Enrineer Date:

Owner or Owner's Desipee, Title CERTIFlCATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arlmricht MutualInsuranee Comosnv (Factorv Mutual Encineerine Association) pf Norwood. Massachusetts b ve inspected the components desenkd in this Owner's Report during the period . G//Ad34 to . 7/ 3/ m 5 . and state that to the best ofmy knowledge and belief, the Owner has pefforni2d examinations ancftaker(corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures desenhd in this Owner's Report. Funhennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. [ /)/x/2dr>t Commissions M4A California Inspector'(Sipaiure ' National Board, State, Province, and Endorsements Date AcIIIN[

             //     ( /.       '

d Mo: 640514s2000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. % >your=_=..renAsm cod.s.ce_xi

,3 1. Owner: Southern California Edison Company Unit: 2 ( ) 2244 Walnut Grove Avenue MO: 94052031001 w/ Rosemead, California 91770 Rspec: EREF-0172 P&ID: 40141C B-2

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128  : S2430b2
3. WorkPerformedby: Southern California Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A Expiration Date: N/A
4. Identification of System: Main Steam
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. S'75 Addenda (Vah ei Code Case: 1781.1974 Edition. S'74 Addenda (Flance Boltirici (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Kepaired, ~ ASME Name of Name of Manufacturer National Other Yeir ~ Replaced or Code Component Manufacturer Serial No., Board No. Identdication Built Replacement Stamped YeWNo 40" Gate Valve WKM 484772 1377 2HV8204 1978 - Yes 5/8"-l1 Heavy Hex Nova Machine Ht. Code C9N N/A RSO 2648-93, N/A Replacement No Nut SA-194 Gr. 2H (~~h 7. Description of Work: One flange nut was replaced for main steam isolation valve 2HV8204. l I I l

8. Tests Conducted: System Functional Pressure Test Pressure: 904 psie Temp: N/A n

\-

     -                _ . _ .                                             - _ ..,n....                              _ _ .,_              ,._e,..           _ . _ _ , -
3) each sheet a numbered and ou mante of shoes a tocorded at Sw top of th. % and (4) each sheet a svnaled and dated by On Onner er Owns's dengnse and Ow A1A.

1 FORM NIS-2 (b:ck)

9. Remarks: None.

m mmsaw,wm w uaaue CERTIFICATE OF COMPLIANCE We certtfy that the statements made in the report are correct and this rentacement conformstotherules of the ASME Code, Section XI. repairorreptuement Type Code Symbol Stamp: N/A Certificate ofA on No- N/A ExpirationDate: N/A Signed: o unervisine ASME Codes Encineer Date:

                                                                                                               /6 -

ND Owier or Ow5er's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Californin. and employed by Arkwricht MutualInsurance Companv (Factorv Mutual Enrineerine Associationi of Norwood. Massachusetts has e inspected the components desented in this Owner's Report ---- during the period 2//7/96 to Ef/2/ 8 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures desented in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, reither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his emplo shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or conn led wi' 6is ~ ection tooA Commissions l California #[ Inspector's Signature National Board, State, Prosince, and Endorsements Date w uquof 3,1995 - U()

                                                                                       /

uo: sa m a ,

                                                                  -                                                                   j l
                                                                                                           ^
                                        -                                                           ~

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.n.ee.nrai. w .rm An a c.* - n tIel2

1. Owner- Southern Cahfomia Edison Cornpany Unit: 2-b)

( 2244 Walnut Grove Avenue Rosemead,Califamia 91770 MO: 94052378000, 94091025000,001 FCN: F9329M,F10663M,F10664M

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 Rspec : 005-95,144-94 R2 P&lD: 40lllA
3. WorkPerformedby: Southern CaliforniaEdison Company N-5: S2-1201-3-12 Bechtel Construction Company Type Code SymbolStamp: N/A AuthorizationNo: N/A ,
4. IdentificationofSystem: ReactorCoolant ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1-NF and 2.1974 Edition. S'74 AAAanAm (Pininn/In=tahinni Class 2.1986 Edition.No AdAanA= (Valvel Code C=aac None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements 1989 Edition. No A AAanAm
6. Identification of Components Repaired or Replaced and Replacement Cnmpanents:

Rapeired, ASME Name of NameOf Manufadurer National Other Year Replaced or Code Cornpoucot Manufacturer Seria!No. Board No. Ideaufication Built #1- Stamped Yes/No , Pipe Spool Bechtel N/A N/A S2-RC-058-01C, 1979 Repaired Yes S2120IMIh58 3/4" Orifice Plate N/A 2FOO296 N/A Replaced No , 3/4" NPS Sch 160 Consolidated Heat SW769 N/A RSO 0153-95, N/A Replacement No Pipe PowerSupply SA-376 TP316 1* NPS Sch 160 Pipe Dubose National HeatK36089 N/A RSO 0229-95, N/A Replacement No Energy SA 376 TP316 3/4" 2500# Sch 60 WFI Heat 449WNE N/A RSO 1896-94, N/A Replacement No . RFWNFlange SA-182 F316,

                                                             \                                CR-3004-94 RI 1"x 3/4" Sch 160 Pipe WFI                        Heat 233VNA              N/A       RSO 1896-94,          N/A Replacement      No Reducer                                                                             SA-403 WP316                                                   !

1" NPS Sch 160 Pipe Consolidated HeatD00209 N/A RSO 0533 92, N/A Replacement No Power Supply SA-182 F316 l' 1500# RFWN Sch Energy Steel Heat 1G1048 N/A RSO 0533-92, N/A Replacement No 160 Flange Supply Co. SA-182 F316 12*x12*x 1/2* Plate Consolidated Heat 224554W N/A RSO O153 95, N/A Replacement No Power Supply SA-240 Tp304 12*x12*xl" Plate Consolidated Heat 914435 N/A RSO O153 95, N/A Replacement No Power Supply SA-240 Tp304

7. Description of Work:

In accordance with FCNs F9329M, F10663M and F10664M, flow orifice 2FOO2% was replaced with an orifice gate valve - allowing full flow when needed. The reactor head vent spool 2 RC-058-ID was reconfigured and the project class boundary was relocated. 'Ibe fabrication and NDE were performed by Bechtel on CWO 94091025. Installation andfinalpressure testing were performed by SCE on MO 94052378. n 8. Tests Conducted: System Hydrostatic Pressure Test Pres: 3106 esir Temp:H!/A ( System Leakane/ Functional Pressure 2243 vsie 115E TEi!

  • k.;.
                       .*.".lO'0"h?-l".*:"17eT.ll"s".ll'Til0'A!Of1""'OTA"o".l.'""*                             O.*"."."".Ml*m"*

FORM NIS-2 (b:ck) ,

9. Remarks : ne replacement pipe heat code D00209 was certi5ed to a higher code class, ASME III-1, as allowed by ASMEIII, paragraph NCA-2134.

we u.a= = . a. u , . . e CERTIFICATE OF COMPI.!ANCE We certify that the statements made in the report are correct and this renair and rentaeement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code SymbolStamp: N/A Certi5cate ofAuthorizatiou No: N/A ExpirationDate: N/A Siped: / IMunervisine ASME Codes Eneineer Date: C!f AT Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwrirbt Mutual Insuranee Comoanv (Factorv M6tual Enrineerior Association) of Norwood. Massmebusettspve Wed the components described in this Owner's Report during theperiod f#/ M 9 6'~ to bhN6 . and state that to the best ofmy knowledge and belief, the Owner bas'perfanned examinations and'taken corrective measures desenkd in this Outer's Report in accordance with the requirements of the ASME Code, Section XI. By siping this certincate, neither the Inspector nor his employer makes any warranty, syd or implied, concerning the examinations and corrective measures desenhlin this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ' 'on. ) MActM Commissions /8[d Califomia Insp'ectof's Sipature/ 6 National Board, State, Province, and Endorsements

                                                          \'

Date d 8[

              /

N A Mo: 94052378000

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS un e n. - <n. m ac ar , m e2d2

1. Owner: Suthern Califirnia Edism Company Unit: 2

(^)\ ( 2244 Walnut Grove Avenue MO: 94052378000,94091025000,001 R-a, California 91770 FCN: F9329M,F10663M,F10664M

2. Plant: San Onofre Nuclear Generatmg Statim Rspec : 005 95,144-94 R2 San Clemente, California 92674 0128 P&ID: 40111A
3. WorkPerfannedby: Southern CaliforniaEdison Company N 5: S2 1201 3-12 Bechtel Construction Company Type Code SymbolStamp: N/A AuthonzationNo: N/A i
4. Identification of System: Reactor Coolant ExpirationDate: N/A i

. 5. (a) Applicable Construction Code: ASME Section III Class 1.1-NF and 2.1974 Meion. S'74 ANAm (Pinine/In=tallationi Class 2.1986 Edition.No Addenda (Valvel Code Cases: None < (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda Repaared, ASME Name of Name of Manufacturer National Other Year Replacad or Code Component Manufadurer Serial No. Board No. Identification Built Replamment Stanyed Yes/No 3/4" NPS Pipe NPS Products, Heat 22546NH N/A RSO O142-95, N/A Replacement No Anchor Inc. SA-240 Tp304 1" Bolted Bonnet BW Anchor Darling ET967-1-2 N/A RSO 1481-94, 1994 Replacement Yes Gate Valve S2120IMU995 ' 3/4"-10x31/4deavy Nova Machme Heat 4-9943FA N/A RSO O476-95, N/A Rep!mt No HexBolts(4) Products SA-193 B7

 /*                                                                                                                                           i

( ( 3 1

                                                                                                                                              )
                                                                                                                                        .      i Owner-                Ih $ N                                      ANII: [               d           I                                    l Initialsyste                                                    Initials /Date
  -a u .a- oa_s ,naa-mx---- . r.--.aa w - s 1

r , i 1 O.) i l l 2 l O.! i j l l

+

Y O

1 i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS unwr=r s wmuure. dew.oo

                                                                                                                                                                                       )
1. Owner: Southern CalifomiaEdison Company Unit: 2 D 2244 Walnut Grove Avenue MO: 94052571000 Id Rosemead,Califamia 91770 Rspec EREF-0175,
2. Plant: San Onofre Nuclear Generating Station P&ID: 40lllD l San Clemente, California 92674-0128 N-5'* S2-1201-3-7
3. WorkPerfonnedby: Southern California Edison Company Type Code SymbolStamp: N/A j Authorization No: N/A l Expiration Date: N/A i
4. Identification of System: Reactor Coolant i

S. (a) Applicable Construction Code: ASME Section IIL Class 1.1971 i'@ ion. S'73 Addenda. Code Ca=ev None

                                                                                                                                                                                       ]

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                           .                                                                   Repaired. ASME Name of                      NameOf.                     Manufacturer              National                Other                Year      Replaced or Code Component                    Manufacturer                    Serial No.             Board No.            Identification          Built      Replacement Stamped       ;

Yes/No I 4" Flow Control Hammel-Dahl 74/5797/002 N/A 2PV0100B 1978 ---- Yes Valve Conoflow Upper Bonnet Anchor / Darling ET-455-1-2 N/A RSO2314 93, 1993 Replacement Yes i Assembly CR-2004 93 ) Upper Bonnet Nuts ITT HammelDahl N21-1 N/A RSO 2-P-855-83 N/A Replacement No (7) k Upper Bonnet Nut ITT HammelDahl N21-1 N/A RSO 3115-85 N/A Replacement No l

                                                                                                                                                                                      ],
7. Desenption ofWork:

The pressunzer containment spray valve was disassembled for refurbishment as a repetitive maintenance action. The upper bonnet assembly was replaced, which includes the following ASME items: upper bellows bonnet, valve plug and upper bonnet studs. The upper bonnet nuts were also replaced. The replacement upper bonnet studs and nuts were VT-1 examined with satisfactory results.

8. Tests Conducted: System Leakace Pressure Test Pressure: 2258 psis Temp: 110*E l

0 - - _ - - , - -....t _ . - -..--..- -.-

3) each sham a ai.nhand and the amnbar of sheet a reemded at $m top of ess farm, and M such sheet 5.uheled and daeed by die Owner or Ownerg deugnse and die h 1

i

i,- .

                                 ~

FORM NIS-2 (b:ck)

9. Remarks : CR-2004-93 reconciles the replacement upper bonnet assembly, which was certified t) ASME III 1,1977 Edition, No Addenda.
                                                    =       v , ,, m e m .->

CERTIFICATE OF COMPLIANCE of the ASME Code, Section XI. npairor replacement Type Code Symbol stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: / / Supervisine ASME Codes Encineer Date: 8 9/95 Owser or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessg! Inspectors and. the State or Province of California. and employed by A rkwricht Mutual insurance Company (Factorv Mutual -- Encineerine Association)pf Norwood. Massachusetts have inspected the components described in this Owner's Report during the period // l'l/ 95 to #/4M5 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg th examinations and conective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kbid arising from or confected with od.

                %              DAt                     Commissions.                    1574 Ceiifornia dfl Inspector's Signature                                     National Board, State, Province, and Endorsements Date $rUMLo$ b. $00$

U G 9

I I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4 z..e.e by n= %=. .ro. e.sur e.* s-..m Shees I ofI

1. Owner: Southem Califomia Edison Company Unit: 2 (N

'() 2244 Walnut Grove Avenue Rosemead, California 91770 MO: 94060552,94061068 Rspec 027 94,029-94 P&ID: 40124B D-4 i i l

2. Plant: San Onofre Nuclear Generating Station
                    ' San Clemente, California 92674-0128                                            N 5:        S2-1208-10                      i 1

i

3. WorkPerfonnedby: Southern California Edison Company 1 Type Code Spnbol stamp: N/A i
4. Identification ofSystem: Chemical and Volume Control ^"

E Dat

5. (a) Applicable Construction Code: ASME Section M. Class 2.1974 Edition. S'75 Addenda (Valvel S'74 Addenda (Tubine
                                             & Fittinci Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. IdentiScation of Components Repaired or Replaced and Replacement Components: -

Repaired, ASME Name of . Name of Manufactner National CKher Year Replaced or Code Componers Manufacturer Serial No. Board No. Identification Beilt Replacement Stamped YesWo 3/8" Gate Valve Imperial Clevite 40916 N/A S21208MR320 1984 Replaced Yes 3/8" Gate Valve Imperial Clevite 43155 N/A RSO4623 86, 1986 Replacement Yes -  ! SA-182 Gr. 316 1/2" x 3/8" ParkerHannifm Trace Code UAYU N/A RSO2144 93, N/A Replacement No Pipe-to-tube Adapter SA-479 Gr. 316 3/8* x ,065" Adapter Sandvik Steel Heat MS518 N/A RSO 2359 93, N/A Replacement No .

/O  Tubing O                                                                                     SA 213 Gr. 316
7. Description of Work:

The instrument line from accumulator S21208MW247, up to and including S2120SMR320, was replaced in accordance with FCN F48323. Le replacement pipe-to-tube adapter was machined to accept a socket-weld prep. It was then we,lded to the accumulator using weld record WR2-94-133, Rev.1. Reference NCR 92060024

8. Tests Conducted: System Functional Pressure.les Pressure: 23d3 nsic Temp: N/A
            =. _= e.=.=ce, .=e== = =:== ==-                                                                                                     ,

FORM NIS-2 (b:ck)

9. Remarks : None.

m u-wwa.m u m .ws.a, CERTIFICATE OF COMPLLLNCE We certify that the statements made in the report are correct and this renlacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: / i/[M Sunenisine ASME Codes Encineer Date: f/5/95 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricbt MutualInsurance Comnanv (Factorv Mutual Enrineerine A ssociationfofNomood. Massachusetts have inspected the components described in this Owner's Report during the period (o//d/9// to 4/7/96 , and state that to the best of my knowledge and belief, the Owner has perfo6ned ex'aminations and taken'correctiv'e measures described in this Owner's Report in accordance with the requirements of te ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne 's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. Inspector's Signature / M Commissions /b2 Califomis National Board, State, Prosince, and Endorsements DateN/ 7, /NS~

            /

Mo; D40605!2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ' u % = % erm.asuccs x shamiet3 G-- 1, Owner- . Southern Califamia Edison Company Unit: 2 2244 Walnut Grove Avenue k ). Rosemead, California 91770 MO: 94061023000 Rspec EREF-0004 i

        - 2.' Plant:     San Onofre Nuclear Generating Station                                  P&ID: 40ll2A D-2 San Clemente, Califomia 92674-0128                                    N-5:      S2-1204 34
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A AuthonzationNo: N/A
4. Identification of System: Boric Acid Mix and Storage
                                                                                                                 **                    ^
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition. S'73 Addenda Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: >

Repaired, ASME Name of Name of Manufacturer National other Component Year Replaced or Code l Manufacturer Serial No. Board No. Identification Built Replacement Staged ' Yan/No l' Y-type Globe Kerotest YE3-17 N/A S21204MR292 1978 - Yes c Valve i Dise BW/IP 311023 SN 75 N/A RSO l826-94 1994 Replacement Yes - International ( 7. DescriptionofWork: An active boric acid leak was evident at the Kerotest valve in location S21204MR292. The valve was disassem i cleaning and inspection and reassembled after replacing the valve disc. l l

8. Tests Conducted: System Functional Pressure Test Pressure: 1486 nsin Temp: N!6
      -       _ .                  ., _ _ _ m_..                                    .... _ .-,

3)em.b shes e nebered and tw nurnha of sheets a rumorded er su any of e. farig and (4)each shem sOwner's

                                                                                                                   .vtaleddesgpas and dated and Onby AIA,the Owner . .h . ._._ . ._ _

FORM NIS-2 (back)

9. Remarks : l The replacemen2 dise was certified to a higher code class, ASME III-1, as allowed by ASME III, paragrap ~

NCA-2134 w~ um s. man w .ma > CERTIFICATE OF COMPLIANCE We certify that the ststements made in the report are correct and this rentacement confonns to the rules of the ASME Code, Section XI repair or replicaners Type Code S3 Tnbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped: Owner or Outer's.Desipee, Title Stmervisine ASME Codes Eneineer Date: / M CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors a the State or Province of California. and employed by A rkwricht MutualInsuranee Comoanv (Factorv Mutual Eneineerine Association) of Norn:ood. Massachusetts pare inspected the components described in this Owner' during the period ////4/'74- to 7/ 3//95 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and takeri corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer conne shall be liabic in any manner for any personal inju:y or property damage or a loss of any kind arising from or with s ectio Of.CC/C &. b?[un Commissions d California Inspector's Sipature , National Board, State, Province, and Endorsements Date - . [ I [8.96 VD

                                                                                                                                                                                                               =

MO: 94061023000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS as n d w m. r .re. Asha e.d. s w.m asaseo

n. 1. Owner: Southem CaliforniaEdison Company Unit: 2 2244 Walnut Grove Avenue MO: 94061026000
      -(V)                                           Rm=A.Califamia 91770                                             Rspec EREF-0018 P'&ID: 40112B C-1
2. Plant: San Onofre Nuclear Generating Station N-5: S2-1204-12 San Clemente, California 92674-0128
3. WorkPetformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling
5. (a) Applicable Construction Code: ASME Section III. Class 2.1971 Edition. S'73 A AA=1= Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared. ASME Name of NameOf Manufactunt National Other Year Replaced w Code CP' Manufadurer Serial No. Board No. Identificatum Built Replacement Stamped 1 YmW 1* Globe Valve Kerotest TNE6-16 N/A S21204MR095 1976 - Yes Bonnet Kerotest AD031-6 N/A RSO 2-P-1372-83, N/A Replacement No 9915-3-(l)Z Disc Kerotest CBR2-62 N/A RSO 2758-92, 1992 Replacement Yes 9915-9-1

        ,O V                                                             ~
7. Description ofWork:

ne valve was disassembled for inspection due to the accumulation of dry boric acid crystals at the pipe cap, ne valve bonnet and disc were replaced and the valve reassembled. l t  !

8. Tests Conducted: System Insertice Pressure Test Pressure: 494 psig Temp: N/A .

_ _ _ _ _ _ _ _ m .._.... _ _ ._.. _ _ _

3) each ehem o numbe=1 and su member ersheen a amore.d si se emp ers. % .d M eum ah.m a mama.d and duend by tu owns er osma4 dumpse and te A1A.

, FORM NIS-2 (b:ck)

9. Remarks : The replacement beenet and disc were certi5ed to ASME M 1 as allowed by ASME III, paragraph )

NCA 2134.. - i vw=.m. u . u.= a,-= = = e CERTIFICAE OF COMPLIANCE We certify that the statements made in the report are concet and this renlacement conformstotherules of the ASME Code, Section XI. npah or replacement Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed- Sucenising ASME Codes Enrineer Date: 6!14[9f Owner or Dwner's Designee, Title 7 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vesse1 Inspectors and the State or Province of California. and employed by Arkwriebt Mutual Insurance Comnanv (Factory Mutual Enrineerine Association)pf Norwood.Massaebusetts have ~ the components described in this Owner's Report during the period //)/7/94 to 4. /J4 .s, . and state that to the best of my knowledge and belief, the Owner has pdfordied' examinations and talien corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, syd or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this * 'en.

                          .ZMrM A                      Commissions            (L.2.                 California Inspector's Signature /

National Board, State. Prosince, and Endcrsements g.

                                                          \

Date . JM.$, /99( - i / O Mo' M1M

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Fmqured by 9e Piermons of the ASME Code SectwmXI

                                                                                                                                            $heet I of1
 -       1. Oner: Southern California Edison Company                                                                                         Unit: 2 ,

! 1 2244 Walnut Grove Avenue MO: 94061280000 Cl Rosemead, California 91770 Rspec: 030-94 P&ID: 40124B D-3

2. Plant: San Onofre Nuclear Generating Station N-5 ' S2-1208-5 San Clemente, California 92674-0128
3. WorkPerfonnedby: Southern California Edison Company Type Code SyTnbol Stamp: N/A
4. Identification ofSystem: Chemical and Volume Control Authorir.ation No: N/A Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S*75 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME NameEf Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Iderdification Buik Replacement Stamped Yesh'o Vertical Discharge Greer Hydraulics, GHI-2981 234 S21208MW219 1978 -- Yes Accumulator Inc. Valve Stem Greer Hydraulics, Heat 48361 N/A RSO3253 91, N/A Replacement No Inc. SA-479 Or. 304, l I PN408319 /m (v) 7. Description of Work: The valve stem, an integral attachment to the valve bladder assembly, was replaced due to bladder leakage.

8. Tests Conducted: System Functional Pressure Test Presaire: 2343 psig Temp: N/A

,/

   /

No!T.: Surplemansa! . beats e en lorin af hsis, sketches, or drewmss may be used provided 0) asis s 81/2 et a l a et, o) rdarmation a hems I through 6 on Ota report a mchaded on each sheet.

3) each sheet a nenbered and em nunbes ershese a succeded et 0= tip of om form, and (4)each sheet a estaled and ested by em Osmer er Owners daugnes and the AIA.

l

' l! FORM NIS-2 (back)

9. Remarks: None.

an ,uo m.au.p.n.i.w.wo, . CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this renlacement conforms to the rules of the ASME' Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: MM Ib Surenisine ASME Codes Encineer Date: f/5/96 Owner or Owner's Desience, Title ' CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsuranee Comnanv (Factorv Mutual Encineerine Association) of Norn ood Masischusetts have inspected the components described in this Outer's Report dwing the period 4o//4-/9# to #/7/96 . and state that to the best ofm) hoowledge and belief, the Outer has perfo(med ex'aminitions and tak(n cofrective measures described in this Owner's Report ir.t accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, exprest.ed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection. A/f%df>T In5ector's Signature / Commissions /Y M Califomia National Board, State, Province, and Endorsements Date /) 7> Ek?S~ l l uo: oceneocco

                                           ' FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
4. nw h m. re.*s .r m. Asus c.4. s e x: >
      / , ,;

Sheet 1 of 1

  ' \ )\ t.'      1.          Omner: Southern California Edison Company                              ,          Unit:          2-                                  t 2244 Walnut Grove Avenue, Rosemead, CA 91770                          CW6: '         94061923000,14120373000, 75010533000,94120362000,
2. Plant: San Onofre Nuclear Generating Station . 94120179000,94120179001 San Clemente, CA 92674 0128 DCP:, 2 2012.00SN REV. O
                                                                                                             ~ PAID;           401238 .
3. Work Performed by: Bechtel Construction Company N 5: 3 S2 1208 13 . .

P.O. Bor. 450 Repafr Spec: 2012 2 94 REV.1,2012194 San Clemente, CA 92674 0128 .

     -{                                           ,

Type Code Symbol Stamp: N/A

4. Identification of System: Authorization No:

Chemical and Volume Control (1208) . N/A

     .l1                                                                                                        Erpiration Date:                 N/A
 ..               5.          (a)         Applicable Construcuon Code: ASME Section III, Class 2,1974 Edition, W'74 Addenda, Code Cases: None ASME Section III, Class 2 NF,1974, W'74 Addenda, Code Cases: None (b)         Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

ASME Repaired, Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No. Board No. Identification Built Replacercent Yes/No  ? CVCS Purification Filter Greer Hydraulics S/N 2586 N/A S21208-MF 020 1976 Repaired Yes 1 1 Vendor Dws,1814 AA373-D0002 i v

             )

Item #1 Energy Steel and SA-240 Gr. T304 Housing Cover Suppty Co. HT #2C047 N/A R$0 #1332-94 N/A Replacement No Item #3 Energy Steel and SA-240 Gr. T304 Trunion Lug Supply Co. HT #861483AL N/A RSO #1332-94 N/A Replacement No item #4,5 I Energy Steel and SA-240 Gr. T304 j Bolt Stop Supply Co. HT #861483AL N/A RSO #1332 94 N/A Replacement No  ! llem #6  ! Energy Steel and SA479 Gr.T304 Bolt Trunion Supply Co. HT #30830 N/A RSO #1332-94 N/A Replacement No' liem #7 1 1/8*-8-UNC-2A Energy Steel and SA-193 B8M  ! Closure Bolt Supply Cow HT #41040 N/A RSO #0047-95 N/A Replacement No CR 200193

7. Description of Work:

1

      }                      DCP 2 2012.00SN Rev. O modifies the CVCS purification (11ters to 1.nprove ultrafiltration of RCS pcrticulates and reduce /            ;

eliminate personnel radiation exposure and contamination. The CVCS purification illter housing on S21208-MF-020 was j removed and replaced utilizing replacement parts per Dwg.1814-AA373-D0002 CWO 94062923 tracked the vendor pre. ' fabrication of the modified filter internals. CWO 94120373 performed the finervessel cover modifications. CWO 95010533 welded the closure bolt to the m3 sher. CWO 94120362 performed the vendor machining of the filter housing. CWO 94120179 performed the insta!!stion and pressure testing.

      ,          8.

Tests Conducted: System Leakage [] System Functional [x] System inservice [] Hydrostatic [ ] Pneumatic [] Other [] Pressure: 325 psig Temp: N/A 'F

             \

is

             /

i Noic: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information j' in liems I through 6 on this report is included on each sheet,(3) cach sheet is numbered and the number of sheets is recorded at the top of this form, and (4) each sheet is initialed and dated by the Owner or Owner's Designee and the AIA.

a l 4496-- FORM NIS12 (back)

9.
  • Remarts: The cloture bolis (liem #7) were cenified to ASME 1112, '74 Edition,575 which is acceptable per CR-200193.

(Applicable Manufacturer's Data Repor's to be attached) CERTIFICATE OF COMPLLGCE . e Ue cenS that the statements made in the report are correct and this repair and replacement cor. forms to the rules of the ASME Cc46 'ection XL Type Code Symbol stamp: N/A Cenmcate of Authorization No: N/A Expiration Date N/A Signed: 4; O*wr or O'wner s Designee. Title

                                                                      .Steervisint ASME Codes Eneineer           Date         la b ' .19 3 CERTIFICATE OFINSPECTION I, the undersigned holding a valid cotz: mission issued 1y the National Board of Boiler and Pressure Vesse! Inspectors and the State or Prosince of California, and englatd by Ark,a richt Mutust Insurance Company (Factory Mutuai Enetneerine Associetioni of Norwood.)fessschus have inspected the components described in this Owner's Report during the period ///M/9//

to &/S/9M . and state that to the best of my knomiedge and belief, the Owner has performed exanfmations'and taken correefht measures described in this O*mer's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the q exam %ations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his empleStr shall be liable in any manner for any persor.nl injury or prcpeny damage or a loss of any kind arising from or connected with this inspection, g

                                                       ~

Commissions Id California f Inspector's Signature (National Board, State Prcnince, and Endorsements ) Date . ///L [ h p , - - - 19 8W

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u aw hye.en go. Asiac.* s.m xx sh maw a m 1. Owner: Southern California Edison Company Unit: 2 2244 Walnut Grove Avenue (J) k Ra<am-ad. California 91770 MO: 94070315000 Rspec EREF-0207

2. Plant: San Onofre Nuclear Generating Station P&ID: 40ll2D San Clemente, Califamia 92674-0128 N-5: S2-1201 4
3. WorkPerfonnedby: Southern California Edison company Type Code SymbolStamp: N/A
4. Identif2 cation ofSystem: SafetyInjection and Shutdown Cooling Authonzation No: N/A ExpirationDate: N/A 1
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S*74 Addenda. Code Cases: Ne,ne (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

I Repaned. ASME Name of Nameof Manufacturer National Other Year Repland er . Code e- Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 6*x8" ReliefValve CrosbyValve & N60061-00-0004 N/A 2PSV9349 1984 Replaced Yes Gace 6"x8" Relief Valve Crosby Valve & N60061-00-0003 N/A 026-44409, Tested 1980 Replacement Yes Gage Spare i~ ( 7. Description ofWork: x/ The relief valve was replaced as a scheduled preventative maintenance action with a tested spare. The removed valve was

  • placed in the rebuild program.
                                                                  \
                                                                                                                              \
8. Tests Conducted: System Functional Pressure Test Pressure: 11Qpig Temp: N/A I l

worr. t. t en s= orkm.amw = *>==s s=y w d:-d.d c)== s m at a a.c)mf==== b n = i e me s on em ne t mauda an 4.h se. l

3) each shast a sunbered and ou manbar etshwa a meerdad at te top of as forat and M sed sheet e inenkd and desed by en o.msr er Onei's esense and Ow AR
                                                                                                                                                                             )

1

FORM NIS-2 (b:ck)

9. Remarks : None.

er --. . , m n.om, s. m CERTIFICATE OF COMPIJANCE We certfy that the statements made in the report are correct and this rentacement conforms

                                                                   ~

to the rules of the ASME Code, Section XI. repair orreplacement Type Code SymbolStamp: N/A Certficate ofAuthonzationNo: N/A ExpirationDate: N/A , Siped: 8I Suoervisine ASME Codes Engineer Date: 4[Y&T Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInauranee Comoanv &actorv Mutual l Enrineerine duringtheperiod Association)

                                 ///'7/96of Norwood. to 6/A27/     Massachusetts        have,9Cinspected the components describl
                                                                                   . and state that to the best ofmy knouiedge and belief, the Owner has p(rform'ed examinations and t'a ken 6arrective measures described in this Owner's Report in                       :

accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or j connected with this * 'on. ' [. Brtdfh Commissions /8(>2

                                                                                                ~

California Ins'pector's Sipatde National Board, State, Prosince, and Endorsements

                                                             ~

j

                                                           \-                                                                                  i
                                                             \                                                                                 '

1 Date $Q ' J ' i l i l l l l Mo: 64370315000 *

                                                                                                                                                                                     -l l'

FORM NIS-2 OWNER',S 4a.w ,nioREPORT rr.*s .rFOR REPAIRS OR REPLACEMESTS ne mtr e.e. s.co n / i ("/ 1. *Oumr: Southern Californla Edison Company Sheet 1 of1 Unit: 2 1 2244 Walnut Grove Avenue, Rosemead, CA 91770 CWO: 94071412000,94071412001, 94082321000

2. Plam: San OneDi Nuclear Cenersdng Stadon DCP: 24988.00SN,Rev. 0 San Gemente,CA 92674-0128 f.PalD: 40124A  :

N-5: 52-1208-10

3. Work Performed by: BechtelConstruedon Company Repair Spec: 6988-4-94, Rev. 0
                                                                                                                                                                                       )

P.O. Box 450  : San Clemente, CA 92674-0128 T}pe Code SymbolStamp: N/A Authonzation No: N/A

4. Identification ofSptem: Chemical atd Volume Control (1208) Expiradon Date: N/A
5. (a) Applicable Construcdon Code: ASME Seedon !!!, Class 2.1974 Edidon, S'74 Addenda, Code Cases: None (Piping)
                                                             +

ASME Secdon III, Class 2,1974 Edidon, S*75 Ad dends, Code Cases: None (Valve)

                                            }.

(b) Applicable Edition of Section XI Ud!! zed for Repairs or Replacements: 1989 Ediden,No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

ASME Repaired, Code Name of Fame of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Seria!No. Board No. Identification Built Replacement' Yes/No Pipe (Mat'l Onfv) Babcock & Wifcer Heat #M9774 N/A Spool PS2.VC 007-011 N/A Altered No Item 85 4" x 3/4" 30008 S.S. SA122 Or.P316 , Sockolet %71!ne- lit #775VNA N/A RSO W1396-94 N/A Replacement No item #6 i [m) Consolidated SA376TP304 i \j 3'4* Sc!L 40 $1 Pipe Power Supply HT #9E4490 N/A RSO #3287-93 N/A Replaecment No

                                                                                                              !!cm #7 3/4" 6000# S.S. SW Oats            Henry Vogt                                             $2-1208 MR471 Vahi                               Machine Co.       S/N 16-216845              N/A       RSO #204S.93              1993    Replacement             Yes
7. Description of Work: Vent valve $2120!MR671 was added to line $2120tMIh07 to facilitate the performance ofIST on 2LV0227B.

Material verification and prefab under CWO 94071412, irs.a!!ation and htE under CWO 94082321. Drawings: ISO-521208 ML.007,Sht 2 Rev.4,1DCN S 1 Valve-SO23-4081 10-49 & 182

8. TestsConducted: SystemLeakage[] Syste:nFunctieaal[] Sptemlnsersice[X1 Hydrostabe[] Pneumatic [] 0;her[}

Pressure:50 psig Temp:N/A (s ) Note: Supplemental sheets in the form oflists, sietches. or drswings may be used prodded (1) she is * % hs. x 11 in (2)information in !tems I through 6 on this report is included on each sheet. (3) each sheet is numbered and the number ofsheets is recorded at the top of this form, and (4) each aheet is initiated and dard by the Omr or OmW Designee and the AIA.

FORM NIS-2 (baek)

9. Remarks: None.
                                          @pplicable Manufacturer's Data Reports to be a:tached)
                                                                                    ~                                         -

CERTIFICATE OF COMPLIANCE We certify that6e statements made inthe report are corted and this reelscement_ conforms to t Type Code Spnbol Stamp: N/A ExpirationDate: N/A Certificate ofAtr.horcadonNo: N/A Date: A k ,19_d7 Owner or Ounefs Signee le _Ambine A5ME Codes Eneineer - Deagno,uc . 1 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commasion issued by the National Board cf Boiler and P Californla, and employed by Arkwrteht Mutual Insurance Comnenv //= /- (Factory 444 toMutual Entineerine Asseets Massa chusetta ljve inspected the components described in ithisdtaken corrective Ouner's Report durir!g A//e/96 mdsures' described in this Ouner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his emplopt makes any warranty, expre corrective measur es described in this Ouwe/s Report Tunbennore, neither the Inspector nor his en:p personalinjury or pr -rty damage or a loss of any kind arising from or connected with this inspection. AAoM Commasions [o b Califomia National Board, State, Province, and Endorsements ) Inspeddr's Signature /

                                          ~

Data b.' 19h$ f O l

i l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS { As me, d dye.pi-ms.re. Asur e.d.s.aorm j sh.a s a s

,s       1. Owner: -Southern Califomia Edison Company                                                                   Unit 2

( ) 2244 Walnut Grove Avenue MO: 94071416000 l V Rosemead, California 91770 Rspec 074-94 P&ID: 40141D E-4

2. Plant: San Onofre Nuclear Generating Station p,3*

San Clemente, California 92674-0128 N/A

3. WorkPerformedby: Southem California Edison Company Type Code SymbolStamp: N/A Authon,zation No: N/A
                                                                                                                               *         **                     ^
4. Identification of System: Main Steam
5. (a) Applicable Constmetion Code: ASME Section III. Class 2.1974 Edition. S'74 Addenda (Picine & Installation 11983 Edition. S*85 Addenda (Valvel Code Case: None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufacturer National Other Year Replaced or Code CP Manufacturer Serial No. Board No. IderanScation Built Replacement Stamped Yes/No 1/2" Globe Valve Anderson- N26728 N/A S2130lMUO20 1991 Replaced Yes Greenwood 1/2" Globe Valve Anderson- 2878-2 N/A RSO 0755-94 Replacement Yes Greenwood I/2" Sch 80 Pipe Hub, Inc. Heat MS349 N/A RSO 3087-93 N/A Replacement No r j SA-376 IP316 V

7. Description of Work:

The valve was found frozen in the open position and required replacement. The pipe nipple on the upstream side of the valve was also replaced. Installation and NDE was performed in accordance with weld record WR2-94-2SS.

8. Tests Conducted: System Functional Pressure Test Pressure: 865 usia Temp: hi!/.A a

No!E Sa Ac_" sheets a tu farm of be, sketches, er desevnp may be unesi prended 0) am a t l?J ut a i1 m, C) rJarmaban a hems i Ormyh 6 en the report a mchaded en each shout, 3)each sinet n - 2 and tw nwnber of sheets a recorded at ow top of tps famt and (d) serb stuet a subaned and dated by em Owner e Owner's desense and the A1/L

FORM NIS-2 (biek)

9. Remarks : None.

m_

                                                  .7
                                                  .               , m- %

CERTIFICATE OF COh&LIANCE We ecmfy that the statements made in the report are correct and this renlacement conformsto therules of the ASME Code, Section XI. repair errepluemes Type Code Spnbol Stamp: N/A Certi5cate ofAuthorization No: N/A ExpirationDate: N/A Signed: f// 2. - Suoervisine ASME Codes Eneineer Owner or Oner's Designee, Title Date: 7'

                                                                                                         /!f"3 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orProvince of California. and employed by Arkwrieht MutualInsurance Comnanv (Factorv Mutual Eneineerine Association 1 pf Norwood. Massachusetts haye m' spected the components desented in this Owner's Report during the period      /d/4 f/94- to 7/'5f/95                          . and state that to the best ofmy knowledge and belief, the Owner has perform (d examinations and faken 6ctrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owrer's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this in9ection. Mr7T Commissions /[dd California Inspector's Signature ' National Board, State. Province, and Endorsements Date . 3 $f/9.04~

               /   ( /\ /

q l l i l l l l l 4 hao: pag 7141 goon e l

y' o

                                                                                 ,;                                                                                                                     *"' ~1 m        ,
                                                                                                                                                                                                      .          2
                                                                                                                                                                                                               't 6         .-                             .

l

                                                    ~ FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS                                                                                                      i As m gebed ershe Ps sheims ershe A8ME C=de Sosses M I

D . . l k")i Sheet 1 of1 ,

                        ' 1.          Owner' Southern California Edissa Cessyemy                                                         Unit:                      2                                            l 2244 Walmet Grove Avesse, ma======d, CA 91770                                         CWO:                      :94071527000                                  '

DCP: 24908.00SN Rev. 0 . l

                       ' 2. '         Flenc , San Osehe Noclear Generntlag Staties                                                       FAID:                      N/A              - 

( Seaen sa CA 92674 0128 i N.5: 53 1204 24 f i

                                                                                                                                                                                                               .b 3..         Wort Performed by,                        Beebsei constructica Ceampany .                          Type Code Symbol Stamp:                        .N/A F.O. Bos 450                                                                                                                   .{

Ausbostantion No: N/A -  ; San Clemente, CA 92674 4 128 Expiration Date : N/A' l 1

4. . Identification of System. Safety Indeetlen (1204) 5.. (a) - Ahdicable Construction Code ASME Secties III, Class 2.NF,1974 Edities, Samuner 1974 Add ==da,  !

Code Cases: 16445 J. I

                                                                                                                                                                                                                 \

Applicable Edition of Section XI Utilized for Repain or Reptar*'nents: 1989 Editlee, No Addenda (b)-

6. Identification of components Repaired or Repload and Replacement Components:
                                                                                                                                       ,                                      Repausd,         A5ME              f Name of                    Name of                 Manufacturer            National ~             Other                          Year - Replaced,or .       Code             !

Component Manufacturer Senal No. . Board No. Identification Built Rar8-'. Stamped , Yes/No l Mechanical Snubber . .

                                                                                                                                                                     .       Fer====ely            .

l FSA1/2 21/2 Pacific Scientific 3505 N/A $2C419-H409 1978 Deleted .- Yes  !

7. Description of Work: Remove snubber 52.CS419-H-009. The removed snubber was placed into the snubber rebuild program. '!
8. Tats Conducted: N/A I T

I l J

                                                                                                                                                                                                               'I
                                                                                                                                          ~

J l l

                   .                                                                                                                                                                                               l Cw g
                                                                                                                                                                                                               -I Note:        Supplemental sheets in the fonn of lists, sketches, or drawinCs may be used provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded                                            'j at the top of this fonn. and (4) each sheet is inhialed and dated by the Owner or Owner's Desience sad the AIA.
             ~
                                                                                                                                                                                                               .j j

FORM NIS.2 (back) I

9. Remarts: None.

(Applicable Manufacturer's Data Repons to be attached) l k i i CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this .deletten conforms to the rules of the ASME Code, Section XL Type Code Symbol Stamp: N/A Certificate'of Ai

  • orization No: N/A Expiration Date N/A Signed- #$ .Supervisinr ASME codes Encineer Date /Y .19M

. Owmer or d%er's Designee, Title CERTIFICATE OF INSPECTION I, the undmigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California and employed by Arlmirbt Mutualinsurance Company (Factorv Mutual Fnetneerfar Assocla!!ain o b% ci Massachusetts have inspected the components described in this Owner's Repon during the period /////W to C// W/46 . and state that to the best of my knowledge and belief, the Ommer has perfmed examisfatio6s s'nd taken corrective meisures described in this Omner's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described-irrthis Ommer's Repon. Funbermore, neither the Inspector nor his employer shall j l be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection. Cornminions /((,N California 170t,</228,h4

                                                                                                               ~
                  !aspector's Signature                                              (National Board, State Province, and Endorsements )

Date AJA l $.s 19 h( ,

f 8 FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS a a.,i,.or 6. r.=w.m .t m. asur c.4. sns It

        .Y 'I                                                                                                                            Sheet 1 of1
1. Owner: Southern California Edison Company UrJu 2 2244 Walnut Grove Avenne, Rosemead, CA 91770 CWO: 94071S43000 DCP: 2 69sa.00SN, Rev. 0
2. Plant San Onofre Nuclear Generating Station Pm MA San Clemente, CA 92674 012s N 5: S2-1204-12
3. Work Performed by: Bechtel Construction Company 'l)pe Code Symbol Stamp: N/A P.O. Box 4S0 Authorization No: N/A San Cicmente, CA 92674 0128 Expiration Date N/A
4. IdentiGcation of Sptem: Safety Ig}eedon (1204)
5. -

(a) Applicable Construction Code: ASME Section III, Class 2-NF,1974 Edition, Summer 1974 Addenda. Code Cases: 1644 S (b) Applicable Edition of Section XI Utilhed for Repairs or Replacements: 1989 Edition, No Addenda

6. IdentiGeation of Components Repaired or Rephced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. IdentiGestion Built Replacement Stamped Yes/No Mechanical Snubber Facife PSA1/2 21/2 ScientiGc 2367 N/A S2-51050-H-003 1978 Replaced Yes

                                                                                              $2-SI-050-H-003 Rigid Strut                         Lisega                              3922RR15                N/A       RSO . 0030-95        N/A     Replacement
         ,                                                                                                                                                                     No L) 7 Description of Work: Remove / replace snubber $2-SI-050-H003 with a rigid strut. The removed snubber was placed into the                            ,

snubber rebuild program.

8. Tests Conducted: N/A I

I i I I I ( p) q,/ l Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) she is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this forrn. and (4) each sheet is initialed and dated by the Owner or Owner's Desirnee and the AIA.

FORM NIS 2 (back)

9. Remarks: The VT-3 examination was exempted per code case N.01, Paragraph 1230.

(Applicable Manufacturer's Data Reports to be attached) CERTIFICATE OF COMPLIANCE We cenify that the statemenu made in the report are correct and this _ repiscement conforms to the rules of the ASME Code, Section XI. Type Code SymM Stamp: N/A CertiGcate of Authorization No: N/A Expiration Date: N/A Signed: .Supervisinr ASME codes Enrincer Date: 5!/7 .19E Ommer or[damer's Designee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutus1 Insurance Comnany (Factory Mutual Enrineerine Assorlation) of Nomd. Massachusetts have inspected the components described in this Ommer's Report during the period ///f//W to at// #/&&~ . and state that to the best of my knomiedge and belief, the Owner has performed examinatidns and taken correctfve measures described in this Ommer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certiGcate, neither the Inspector nor his employer makes any astranty, expressed or i:nplied, concerning the examinations and corrective measures described in this Ommer's Repon. Furthermore, neither the Inspector nor his empicycr sha!! l I be liable in any manner for any personalinjury or propeny damage or a loss of any kind arising from or connected with this inspection. m7 hJh Commissions /Idd, Cahfornia Inspector's Signature (National Board, State. Province, and Endorsements ) Date 8A / 19 [ ~

                                                                                                     ~      ~

U '

n. 1 l
                  . .        .                                                                                                                                                  g a                                                                                                                                                                          1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPIACEMENTS                                                                    ' #

As n.g=8s.4 br 6. Ps ess se er 4.asMr cw. s s 2: I 7~- 1

  '{%); J-                                                                                                                                                                      3 Sheet 1of1-                                            l
                        .1.~        Owner: Seattwrn California Edison Casspany                                          Unit         2' 2244 Walent Grove Avenue, "--- - '. CA 91770                                                                                    .l CWO:-       94071544000        ,

j DCP: 2 6988.00SN Rev. 0 l

                       ~ 2.      ~ Plant: ' Saa Omette Neelear Generating Staslea                                       P&ID:        N/A                                        !

Saa r a. , CA 92674 4 128 N-5: S2-1204-34

3. Wont Performed by: Beebtal Construction Company Type Code Symbol Stamp: - N/A 1
                                                                   - F.O. Box 450 -                                     Authorization No:

N/A j San Clemmente, CA 92674 012s - Expiration Date: N/A J; 4.' IdentiGcation of System: Safety injection (1204)  !

5. (a) A'pplicable Construction Code: ASME Sectlen III, Class 2-NF,1974 Edition, Samuner 1974 Addenda, Code Cases: None f 1

(b) Applicable Edition of Section XI UtDized for Repairs or RT-ts: 1909 Edition, No Addenda .!

6.  ;

IdentiGention of Components Repaired or Replaced and Replacement Components: j ASME Repaired, Code - c Name of Name of Manufacturer National Other Component Manufacturer Serial No. Board No. Year Replaced, or Stamped 'j IdentiGcation Buut R ,*- -- st. Yes/No i Mechanical Snubber . ' Fennanently PSA1/2 21/2 PaciGc Scientific #20200 N/A S2 SI.052 H410 1m4 Deleted No i 7. Description of Work: Remove snubber $2-SI-052-H410. The removed snubber was placed into the snubber rebuGd program.

8. Tests Conducted: N/A f

f f i

                                                                                                                                                                             'h e

_ .. I t 4  ! l l

                                                                                                                                                                             -1 l

l i e

                                                                                                                                                                              .i Note:

Supplemental sheets in the form of thts, sketches, or drawings may be used provided (1) size is 8 % in.x 11 in., k(2)informat* m in hems 1 through 6 on this report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the too of this form. an? (4) each sheet is initialed and dated by the Owner or Owner's Desience and the AIA.

FORM NIS 2 (back)

9. Remarks: None.

(Applicable Manufacturer's Data Repons to be attached) CERT $1CATE OF COMPLIANCE , I We cenify that the statements made la the repon are correct and this deletion conforms to the rules of the ASME Code,  ! Section XI. 1 ( Type Code Symbol Stamp: N/A 1 Certificate of Authorization No: N/A Expiration Date: N/A l Signed- / .Simervisine ASME Codes Enrincer Date: I !/ b .19 D l OaTict or Owner's tiesignee, Title l l l CERTIFICATE OF INSPECTION 1 I, the undersigned holding a valid commkdon issued by the National Board of Boiler and Pres:ure Vessel Inspectors and the State or Province of California. and employed by Ark =Tirbt Mutual Inrurance Company (Factory Mutual Enrtneertne Association) of t Norwood. Massachusetts have inspected the components described in this Owners Repon during the period /// / / 9//- l to f //f6 4 6 . and state that to the best of my knomiedge and belief, the Owner has performed examinations and taken conecdve measures described in this Owners Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his emplo3tr shall be liable in any snarmer for any penonal injury or property damage or a loss of any kind arising from or connected with this inspection. M4/28477 ' Commissions NO California f Inspector's Signature (National Board, State, Province, and Endorsements ) DateNzI/A / s 19 [ - V i m

                                                                                                              ~

Q4 ,

                           .                                                                                                                                                               ?l g y 33 .            ...

3 I FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS < l u n.ch.4 6,6. r mi .e n.mes c.a. s s.e m '

  ;jy .                                                                                                                                                                                       :
  .I                                                                                                                                                                                          [
  % ,);                                                                                                                                                                                       1 Sheet 1 of 1 -                            ,
1. Owner: Seeshern Cauferale Edison Company J Unit: 2 (
                                                 ' 2244 Walast Grove Avesne, *                 ', CA 91770                          CWO:         940715$0000                                 -l DCP:          2 490s.00$N, Rev. 9
2. - Plant: - i Sea Omehe Noclear C1. --; Station . ~

{ PAID: . N/A . Saar1 nsa, CA 92674 012s - { N-5: S2-1201 4 ' 1

3. Work Performed by: Bechtel Constructies conspany Type Code Symbol Stamp: , ' N/A - (

P.O. Bax 450 . Authorization No: N/A i San Clemente, CA 92674 0128 - Expiration Date N/A-k

4. Identification of System:  : Rameter Coolant (1201)
5. (a) Appluable Construction Code 'ASME Secties III, Class 2NF,1974 Edities, Saanmer 1974 Addenda, Code Cases:

None (b) Appbcable Edition of Section XI Utilized for Repairs or Replacements: 1989 Editlen, No Addenda ' I Attachment

d. IdentiGcation of Components Repaired or Replaced and Replacement Componente  !

Repaired, A5ME Name of Name of. Manufacturer . National Other Year Replaced, or Code' Component Manufacturer Serial No. Board No. Identification Built R P = =-at Stamped - Yes/No

                                                                                                                                                     ,   7-          ,

Spring Cas N/A N/A ' N/A S2-RC-027-H-003 N/A Deleted No . Mechanical Snubber Permanently PSA1/2 21/2 PaciGe ScientiGe 2633 N/A S2-RC427-H 005 1978 Deleted Yes i M= Snubber i! PSA1/2 21/2 PaciGe Scientific 948 N/A S2-RC427.H404 - 1977 PP-' Yes i S2-RC-027-H 004 Rigid Strut 1.3sega 3922RRIS N/A RSO 0030-95 N/A R P - t' No - I l

7. Description of Woric Remove spring can 52-RC427-H403, snubber $2-RC427-H-005 and replace snubber $2-RC427-H004 1

with sigid strut. '1he reaHrved snubbers were placed into the snubber rebuDd program. 1

8. . Tests Conducted: N/A
                                                                                                                                               ~.
                                                                                                                                                                                              )

_ i i l 1 i Note: Supplemental sheets in the fonn of lists, sketches, or drawings may be used prcmded (1) size is 8 % in. x II in., (2) information in hems 1 through 6 on this report is included on each sheet,(3) each sheet is numbered and the number of sheets is recorded at the top of this form. and (4) each sheet is inhialed and dated by the Omwer or Cax.'s Designee and the AIA.

                                            .                                                                                                        l i

FORM NIS 2 (back)  ! l 1

9. Remarks: 'Ibe VT-3 examination was exempted per code case N-491, Paragraph 1230 k I (Applicable Manufacturers Data Repons to be attached) ,

J CERTlhlCATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section X1.

        'I)pe Code Symbol Stamp: N/A Certificate of Authorization No: N/A                         Expiration Date: N/A

. Signed:__ M/ ll. .Supervisine ASME Codes Enrineer Date: h' Y .19

                  ' Owner or Dwner's Designee, Title CERTIFICATE OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of caltrornia. and employed by Arkwricht Mutual insurance Company (Factor, Mutual Enrincerine Association) of Norwood. Massachusetts have inspected the components described in this Owners Report during the period           ///EN/.l to 6//W/& C . and state that to the best of my knowledge and belief, the Owner has performed examidations and taken correct 4e mF.isures described in this Outers Report in accordance with the requirements of the AShE Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any swranty, expressed or implied, concerning the examinations and corrective measures described in this Ommers Report. Funbermore, neither the Inspector nor his employer shall j ) be liable in any manner for any pe:sonal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

                    -- a    , A,rdI/M
                                   -                                          Commissions /[h          -

Califormia Inspectors Signature (National Board, State, Province, and Endorsements ) Date h$/) y l$., 19 - ' O h

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u ama.or *. w, .ro. ma c.4, sav=xl Shen I ofI

1. Owner: . Southem California Edison Company Unit: 2

( ) 2244 Walnut Grove Avenue MO: 94071579,94092057,94110424 (.,/ Rosemead, California 91770 FCN: F9531M, F10238M,F10239M

                                                               .                             Rspec: 082-94 R1
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 P&lD: 40114D N-5: S2-1206-1
3. WorkPerfonnedby: Bechtej Constniction Company P.O. Box 450 T3pe Code Symbol Stamp: N/A San Clemente, CA 92674-0128 Authorization No: N/A ExpirationDate: N/A
4. Identification of System: Containment Spray '
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. S'74 Addenda (T'ubine/ Installation 11983 Edition. S'85 Addenda (Valvesi Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Re* paired. ASME Name of Manufae:urer National Other Year Replaced or Code Corsponent Manufacturer Serial No. Board No. Identification Built Replacement Stamped

          -                                                                                                                                Yes/No
         ' 'i.:" Piping              Bechtel              N/A                        N/A      S21206ML008,            N/A     Replaced       No S21206ML009 1/2" x .065" Seamless Dubose National          Heat 432578                N/A      RSO 1389-94,            N/A Replacement        No

[] D' Tubing (2) Energy Senice 1/2* x.065" Seamless Teled)me SA-213 TP316 Heat 9E6619 N/A RSO 3305-93, N/A Replacement No Tubing (2) Columbia SA-213 TP316 3/4" SS BW Parker Hannifm Ht Code UBDI N/A RSO 1436-94, N/A Replacement No-Connector (2) SA-479 F316 3/4" x 1/2" SS Tube ParkerHannifm Ht Code HBUY N/A RSO I436-94, N/A Replacement No End Reducer (2) SA-479 F316 1/2* SS Tube Union Puker Hannifm Ht Code UAPE N/A RSO 3286-91, N/A Replacement No (1) SA-403 TP316 1/2" SS Tube Union ParkerHannifm Ht Code UAO! N/A RSO 1675-91, N/A Replacement No (1) SA-182 TP316 1/2" SS Male Parker Hannifm Ht Code CEEH N/A RSO 2009-92, N/A Replacement No Connector (2) SA-403 F316 1/2" 2500# Globe Anderson N70065 N/A RSO 2423-91, 1991 Replacement Yes Valve Greenut>od S21206MR082 1/2" 2500# Globe Anderson N84165 N/A RSO 1182-94, 1994 Replacement Yes Valve Greenwood S21206MR083

7. Description of Work: '

Vent lines S21206MLOO8 and S21206MLOO9 from heat exchanger ME003 were modified and extended in accordance with FCNs F9531M, F10238M and F10239M, to better control the venting of contaminated water. Root valve S21206MR082 was added to line S21206ML008 and S21206MR083 was added to S21206MLOO9.

8. Tests Conducted: Svstem Functional Pressure Test Pres: 330-340 nsic Temp: N_/A fh
  • G
      =

rt=n::::,tr."tze=.:=ct.ce=="==.. _';;='c::"fi;=1-~

T f . FORM NIS-2 (b:ck)

9. Remarks : None.
                         ,                               w. umm.a= % w.:                      ;
                                  ~

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstotherules

                                                  ~

O of the ASME Code, Section XI. repair erreptuement Type Code S 3 mbolStamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Signed: / Suoervirine ASME Codes Encineer Date: ((/7 I 6wner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by 4rkvricht Mutual Insurance Comnanv (Factory Mutual Encineerine Association) gf Norwood. Massachusetts havejnsp_ected the components described in this Owner's Report during the period N/_36/6k/ to 63/4T/99 . and state that to the best of my knowledge and belief, the Owner has peiformed examinations and taken cc:rective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Funhermore, neither the hapector nor his employer shall be liable in any ma .ner for any personal injury or property damage or a loss of any kind arising from or connectedwith thisin en.

                               -I6X/M Inspector's Signature /

Commissions N [.A California National Board, State, Province, and Endorsements D A, a n c m c - e h wo: m nsn $ 1 l i

I l i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A. n ,*.ny e. nm orew ASME Cok SeenmM

  • sheal ers l
1. Owner: Southern California Edison Company Unit: 2 l 7m 2244 Walnut Grove Avenue MO: 94071581 ,94092057,94110421  !

( ) Rosemead,Califomia 91770

    '                                                                                        FCN: F9531M, F10236M, F10237M                           '

Rspec: 083-94R1

2. Plant: San Onofre Nuclear Generating Station San C!cmente, Califomia 92674-0128 P&ID: 40ll4D N-5: S2-1206-1
3. WorkPerformedby: BechtelConstruction Company P.O. Box 450 Type Code Symbol Stamp: N/A San Clemente, CA 92674-0128 Authorization No: N/A Expiration Date: N/A
4. Identification ofSystem: Containment Spray
5. (a) Applicable Conssuction Code: ASME Section Ill Class 2.1974 Edition. S'74 Addenda frubine/Installationi 1983 Edition. S'85 Addenda (Valvest Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of NameOf Manufacturer National 0;her Year Replaced or Code Componera Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 3/4" Piping Bechtel N/A N/A S21206MLOO6, N/A Replaced No S21206MIA07 1/2" x .065* Seamless Dubose National Heat 432578 N/A RSO 1389-94, N/A Replacement No n Tubing (2) Energy Senice SA-213 TP316 i ) 3/4" SS BW ParkerHanmfm Ht Code UBDI N/A RSO 1436-94, N/A Replacement No Connector (2) SA-479 F316 3/4" x 1/2" SS Tube ParkerHa:mifm Ht Code HBUY N/A RSO 1436-94, N/A Replacement No End Reducer (2) SA-479F316 ~ 1/2" SS Tube Union ParkerHannifm Ht Code UAPE N/A RSO 3286 91, N/A Replacement No (6) SA 403 TP316 1/2" SS Male Parker hannifm Ht Code CBEH N/A RSO 2009 92, N/A Replacement No Connector (2) SA 403 F316 1/2' 2500# Globe Anderson N84164 N/A RSO ll82-94, 1994 Replacement Yes Valve Greenwood S21206MR080 1/2' 25004 Globe Anderson N84170 N/A RSO 1182 94, 1994 Replacement Yes Valve Greenwood S21206MR081

7. Description ofWork:

Vent lines S21206MLOO6 and S21206MLOO7 from heat exchanger ME004 were modified and extended in accordance with FCNs F9531M, F10236M and F10237M, to better control the venting ofcontaminated water. Root valve S21206MR080 was added to line S21206MLOO6 and S21206MR081 was added to S21206MLOO7. i

8. Tests Conducted: Svstem Functional Pressure Test Pres: 490 psin Temp: N/A l w===========:== ==-

FORM NIS-2 (back)

         .9. Remarks: None.

ws.- - -.a a,.n. - 3 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confonnstotherules of the ASME Code, Section XL reper wseptacement T3pe Code SpnbolStamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: M/ Sunervisine ASMC Codes Encineer Date: 4' '9I OMier or OwEer's Designee, Title CERTIFICATE OFINSPECTION I, the tmdersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orPresince of California"and employed by Arkwricht MutualInsurance Comenny (Factorv Mutual Enclncerine Association)pf Norwood. Mas:aebusetts have inspected the components desented in this Owner's Repor during theperiod /// ?M/9/4 to 6//S'/QC . and state that to the best ofmy knowledge and belief, the Owner has peiformed examinations and taken codective measures described in this Outer's Report in' accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conce examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any ki d arising from or connected with this inspection. (( Inspector's Signature A2X c/2dM

                                        /           '"

Commissions /I/Is O- California National Board, State, Province, and Endorsements Date ( h e9 / C / W L;~ j a 8 Mo: $4071$41

                                                                                             -- _      m_m__._.______mm.        _______ ___. .__ ..___ -_m_____ ._.m--_.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Nured t y cie Prmsmin sfew ASVE Code SatmM

                         '                                                                                                                  Sheet 1 ofI
1. Owner: Southem California Edison Company Unit: 2
, ~x                         2244 Walnut Grove Avenue                                                                                       MO:         94080194000

( ) Rosemead, California 91770 DCP: 2-6683.04SP Rspec: 061-94

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40172A N-5: S2-1203-32
3. Work Performed by: Southern California Edison Company T3pe Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A S. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition S'74 Addenda. Code case: None (b) Applicable Edition of Section XI Utilized for Repai s or Replacements: 1989 Edition. No Addenda
6. Identification of Components Renaired or Replaced and Replacement Components:

Repaired. ASME Namemf Nameof Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacemers Stamped Yes/No Mechanical Snubber Pacific Scientific 349 N/A S2CC287H009 1976 Permanently No PSA 10-6 Deleted

7. Description of Work:

The mechanical snubber with attachment hardware was no longer required per the latest pipe stress calculation M-1203-287-AA (PSG-116) and was permanently removed in accordance with DCP 2-6683.04SP. The rear bracket wat

,G left in-place. The removed snubbers were placed into the snubber rebuild program.
8. Tests Conducted :H% Pres:N!8 Temp:Na f

i ( Myrre suppien.nuit h ru e she see .f twa sheistus. a drewvos nwy be maad pin, sed 0) sin s : in a a la m.m afern=tua e hems I creush 6 en 8= aPsi e swiudad on =ch sheet.

3) such shese is amnbesd and ou msnbar ersheen a neorded at em top of tus forg and (4) each sheel a betaled and dated by the Owner er owner's designes and on AJA.

FORM NIS-2 (b:ck) I

9. Remarks: None.
                                                      @Ppuebas Mane',wsrs Wta Report to be ana4 bed)

O CERTIFICATE OF COMPLIANCE We certify that the statements made in the repet are correct tnd this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: M// N-Owner or Oumer's Desience, Title Supervisine ASIM Codes Encineer Date: f /MI CERTIFICATE OF INSPECTION - I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insuranee Comoany (Factorv Mutual Engineerine Anociation) of NorwryJ. Massachusetts have inspected the components described in this Oumer's Report during the period

           /2 /5/#/4              .to _ J N 6 /#/8              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taktu corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be .iable in any manner for any sonal injury or property damage or a loss of any kind arising from or connected with this irapec':fn. 3 Wt:cet / s I IL-4 Commissions California I574-Inspector's Signature National Board, State Prosince, and Endorsements on,e 4/sh5

 - a._                                                                                                                                 O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Keewed by Ow Premems ofIhe A$ME code SeetonN! sheni ri

1. Owner [ Southern Califonda Edison Company Unit: 2

/~'S 2244 Walnut Grove Avenue MO: 94080195000 \ / Rosemead,Califomia 91770 DCP: 2-6683.04SP Rspec : 062-94

2. Plant: San Onofre Nuclear Generating Station P&ID : 40172A
                        . San Clemente, Califomia 92674-0128 N-5 : S2 1203-32
3. WorkPerformedby: Southem Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Component Cooling Water Expiration Date: N/A S. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identi6 cation of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Namett NameOf Manufacturer National other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No Mechanical Snubber Pacific ScientiSc 4193 N/A S2CC287H0ll 1978 Replaced Yes PSA 1-4 141/2* Rigid Stmt Lisega S2-CC-287 H-011 N/A RSO 0030-95 N/A Replacement No 3932RRIS

7. Description of Work:

O The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment C/ brackets were reused. A VT-3 examination ofthe support assembly was perfonned after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1203 287-AA (PSG-116) 4

8. Tests conducted :N!A Pres:N/A Temp:H!A

(~~\ G)

    = - - ..e w .r m e                                    . .en       - - >> - .. m . a . u                                         b,nerr.ie       d.e. - ss.a.ded-ee. .e.,
3) and ebem a nenbered and 6e aanbar of abses a reseded as ow top of das fann, and (4) and sbest a smaeled and dated by Ow owner er owners dessnee and du AIA.

FORM NIS-2 (b:ck)

9. Remarks: None.

gAppocaum Manw.staaere Lasu Arports to be stucAed) O

                  ,                                     CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstothe rules                               i of the ASME Code, Section XI.                                              repair or replacement i

T3 pe Code Symbol Stamp: N/A Certificate of Au:horization No: N/A Expiration Date: N/A Signed: NM I Sucenisine ASME Codes Encineer Date: I !95 Oww or Owner's Desicnee, Title CERTIFICATE OFINSPECTION , I, the undersiped holding a valid conunission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insuranee Comnant (Factorv Mutual Eneineerine Association) of Norwood, Massschusetts have inspected the components desenbed in this Owner's Report during the period

             /2/7/94 to                    SN6/95                 . and state that to the best ofmy knowledge and belief, the owner has perfonned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither tr e Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspectic6 /~ t-ten w bh.) m Commissions Californis 1674 Inspector's Signature National Board, State, Prosince, and Endorsements Date d 3 b$ MO. s4080195000 W

           .)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requred h the Promens ef ow A$YI eede $scoenM

                                                                                                                                  $1 wet I ofI

_ l. Oow: Southern Califomia Edison Company Unit: 2 / 2244 Walnut Grove Avenue '() T MO: 9408027S000 Rosemead, California 91770 DCP: 2 6683.04SP

2. Plant: Rrpec: 061-94 San Onofre Nuclear Generating Station San Clemente, California 92674-012S  : 40172A N 5: S2-1203-27
3. WorkPerformedby: Southern California Edison Company Type Code Syrnbol Stamp: N/A Authorization No: N/A
4. Identification of System: Component Cooling Water Expiration Date: N/A
5. (a) Applicable Const.uction Code: ASME Section IIT Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
                                                                                                                                               *                 ~
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufac:urer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Buih Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 3765 N/A S2CC275H008 1977 Permanently Yes PSA 3-5 Deleted

7. Description of Work:

The mechanical snubber with attachment hardware was no longer required per the latest pipe stress calculation 73 M-1203-275 AA (PSG 119) and was permanently removed in accordance with DCP 2-6683.04SP. The rear bracket was ( ) left in-place. The removed snubbers were placed into the snubber rebuild program. %/ . i l i l 1

8. Tests Conducted :E!% Pres:H!% Temp:H% l l

fD Q) l

     =          - u . e.                     .r m .              w.     ,w      d,     u m . .           . n (m.,f                             d          a md--
3) euh sheet a msnbund and te sembs of sheen a ses ded at tw top of the W and H)each shes s kuna)sd and daned by Om owns owners designer and tw A1A

FORM NIS-2 (back)

9. Remarks : None.
                                                      %..      u-1.. . w. unn. w .a.a.o O

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this deletion conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: 84 If Oumer or Owner's Designee, Title Surenisine ASME Codes Encineer Date: f[e 5 CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressur e Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Companv (Factorv Mutual Engineerine A ssociation) of Norwood. Mas s ach usetts have inspected the components described in this Owner's Repon during the period

              /Z/5/94 to                    3// 6/9.5           . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XL By signing this cenificate, neither the Inspector nor ISs employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with this inspectioft.                     (

em ( (C e7 Commissions Califomia I67d-Inspector's Signature National Board, State, Province, and Endorsements oate A] sin i I l l Mo: D40602760C0 9: '

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS - I A.aww.ddvc=n m.= am.Asuse.d.su =xi i

                    ,                                                                                                          Sh.et 3 M t                                                                      j
1. Owner: Southem California Edison Company . Unit : 2-f], 2244 Walnut Grove Avenue MO: 94080282000 V Rosemead, Califomia . 91770 DCP: 2-6683.04SP Rspec : 062-94
    '2. Plant:         San Onofre Nuclear Generating Station .

P&ID : 40172A San Clemente, Califomia 92674 0128 N-5: S2-1203 27

3. WorkPerformedby: Southern Califomia Edison Company Type Code Spnbol Stamp: N/A Authorization No: N/A-
4. Identification of System: Component Cooling Water Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section M. Ches 2-NF.1974 Edition. S*74 Addenda. Code Case: None
       - (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:  ;

Repaired, ASME Narne%f NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer SerialNo. Board No. Identincation Built Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 3788 N/A S2CC275H009 1977 Replaced Yes  ; PSA 3-5 33 3/16* Rigid Strut Lisega S2-CC-275-H-009 N/A RSO OO30-95 N/A Replacement No , 3942RRIS  !

7. Description of Work:

[ The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment \ brackets were reused. A VT-3 examination of the support assembly was pedo med after installation. The removed snubber was placed into the snubber rebuild program. Refe.ence: Stress Cal culation M-1203-275-AA (PSG-119) > 1 Y

8. Tests Conducted :M!% Pres:Fl% Temp: Ele j 3)anch sheet a masnbemt and 9m mesnha af ahese a secorded at es top .f the ferra, and (4)each sheet a sutaW and dated by $w Ouvne er ommer's designes and ou A1A.

FORM NIS-2 (back)

9. Remarks: None.

w a.nuua,mu m a.aa> 0

                 ,                                   CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this replacement confonnstothe rules of the ASME Code, Section XI.                                        repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A                       Expiration Date: N/A' Signed:        MM                                 Supervisinc ASME Codes Encineer                Date:          f       9I

. Owner or OwTier's Designee Title CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Companv (Factorv Mutual Enrineerine Associationtof Norwood. Massachusetts have inspected the components desenbed in this Owner's Repon during the period

              /2/7/94 to J/N-/95                               . and state that to the best of my knowledge and belief, the Owner has performed ekaminations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ouner's Report. Funhermore, neither the Inspector nor his employer shall be liable ipany rnanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio5. , wcu 6 Commissions California 1774 Inspector's Signature National Board, State. Prosince, and Endorsements Date _ a__

FORM NIS-2 OWNER'S As m REPORT i,.or ew p FOR REPAIRS OR REPLACEMENTS , w of Ow ASW Cods $seneM shne1ots .

1. Owner: Southem Califomia Edison Company Unit: 2
,6                           -- 2244. Walnut Grove Avenue                                                                                   DCP: 2-6683.04SP
                              -Rosemead, California 91770-                                                                                  MO:       94080283000

.{b) . Rspec 06194

2. Plant: San Onofre Nuclear Generating Station -

San Clemente, Califomia 92674-0128 P&ID: 40131A N-5: S2-1201-10

          - 3. Work Performed by:                Southern Califomia Edison Company Type Code SpnbolStamp: N/A
4. IdentificationofSystem: ReactorCoolant Authorization No: N/A Expiration Date: N/A- a P
        - 5. (a) Applicable Construction Code: ASME Section lit Class 2 NF.1974 Edition. S'74 Addenda. Code Case: Nong (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: .

Repaired. ASME Nam of Name of Manufacturer National Other Year Replaced or . Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 37420 N/A S2RC073H031 1986 Permanently No PSA 1/4 4 Deleted

7. Description of Work:

The mechanical snubber with attachment hardware was no longer required per the latest pipe stress calculation ' M 1201-073-AA (PSG-148):and was permanently removed in accordance with DCP 2-6683.04SP. The rear bracket was left O in-place. The removed snubber was placed into the snubber rebuild program. l i i l i i i 1 l l I

8. Tests Conducted: H% Pres: FlA Temp: N%

b J 1CTL Supplemensa! sheets a tw Isrm orbsts, sketches, er drs*wes may be used pmided (1) ser s 8 le sL s la m.C)mformaten a lasms 1 deough 6 on em upon is swa ded en euh sheeg

3) sech sheet a numbered and Ou number of sheets a sesorded at the top of this forra, and W each sheet is estaled and Amand by tw Owner as Owners desense and lhe A1A. )

FORM NIS-2 (b:ck) r. s kemarks . None. m w u -,. . w. um . .r.a a, CERTIFlCATE OF COMPLIANCE O We certify that the statements made in the report are correct and this deletion conformstothe rules of the ASME Code, Section XL repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: Ad' z/I/ / --- Sur>ervisine AShE Codes Encineer Date: S6 Owner or OwnePs Desicnee, Title

                                                 ~

CERTIFICATE OFINSPECTION , I, the undersq;ned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Company (Factorv Mutual Enrincerine Anocipdn of Norwood. Mauschusetts have inspected the components described in this Owner's Report during the period 4:/6/74 to d/27/86 . and state that to the best ofmy knowledge and belief, the Owner has , perfonned exammations and taken corrective measures described in this Outer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Outer's Report. Ftuthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspe(tion. 0(DO'1 b dua Commissions Califomia f 574 Inspector's Signature National Board, State, Prosince, and Endorsements sa 199ai D] ate J

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ' As asesred by em Pictisecru .f the AsMI eede sectenXI *

                              ~

shest i efI

1. f0wner: Southern California Edison Company Unit: 2
    ,n                             2244 Walnut Grove Avenue '                                                                            MO: - 94080284000 L Fosemead,Califomia~ 91770                                                                             DCP: 2-6683.04SP L(V)'

Rspec: 062 94

2. . Plant: San Onofre Nuclear Generating Station P&lD : 40131A
                                . San Clemente,Califomia 92674-0128 N 5: S2 1201 10
3. WorkPerformedby: Southem Califomia Edison Company .

Type Code SpnbolStamp: N/A Authorization No: N/A 4.- Identification of System: Reactor Coolant Expiration Date: N/A

5. (a) Applicable Constniction Code: ASME Section M. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None
 ,               (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda i                                                                                                                                                                           '
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Nametf Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes.No Mechanical Snubber Pacific Scientific 9285 N/A S2RC073H038 1900 Replaced No PSA 1/4 - 4 121/4' Rigid Strut Lisega S2 RC 073-H-038 N/A RSO 0030-95 N/A Replacement No 3922RR1

7. Description of Work:

p The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment (' brackets were reused. A VT 3 examination of the suppon assembly was performed aAer installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1201-073-AA (PSG-148) 4

8. Tests Conducted :N % Pres:N/% Temp:Ul%

U .ac. 2 .f e . x d,,dm ..iu,i~mfn

                                                                                                                                      .s              ..           . d.d     4                       .
                    - 3) sash ehesi. numband and se nienho ofsheets .seemeed as the esp.f aus farm, and (4).nch sham. sunnled and duend by en om.ar er ownerie demonse and se AR m._   . . _ _ . . _ _ _ - _ _ _ _ _ _ _ _

FORM NIS-2 (b:ck)

9. Remarks : None.

m -wu.n m a,umn,p.n, w -

                ,                                CERTIFICATE OF COMPLIANCE 9.

We certify that the statements made in the report are correct and this renlacement conforms to the rules of the ASME Code, Section XI. repair orreplacement Type Code S 3 7nbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: 4 i Sunenisine ASME Codes Eneineer Date: f//!95 Owner or Owner's Designee. Title CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of california. and employed by A rkwricht Mutual Insurance Company (Factory Mutual Enrineerine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Repon during the period

           /d/7/94             to  J///e / 95            . and state that to the best of my knowledge and belief, the Owmer has perfonned examinations and taken conective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer sh be lia)1e in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspet: tion. , P en'ut cb Inspector's Signature Commissions Califomia 1574 National Board, State, Province, and Endorsements va,e +ple .o a._ #

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requr by ou Prons.rm of de ASME Co.c Section.1 '

                                                                                                       \

Shcet I ofI

1. Owner: South' ern California Edison Company Unit: 2 x 2244 Walnut Grove Avenue DCP: 2-6683.04SP
) Rosemead,Califamia 91770 MO; 94080324000 V Rspec
061 94
2. Plant: San Onofre Nuclear Generating Station San Clemente. Califomia 92674-0128 P&ID: 40113B N-5: $21204-10
3. Work Performed by: Southem Califomia Edison Company Type Code SpnbolStarnp: N/A
4. Identification of System: Safetyinjection and Shutdown Coolo.g Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Narnesf Narne Of Manufacturer National Other Year Replaced or Code Componen Manufacturer Serial No. Board No. Identification Buih Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 6187 N/A S2S1077H006 1978 Permanently Yes PSA 1/4 Deleted Mechanical Snubber Pacific Scientific 13890 N/A S2S1077H008 1980 Pennanently No PSA 1/4 Deleted Mechanical Snubber Pactfic Scientific 36662 N/A S2S1077H019 1984 Permanently No PSA 1/4 Deleted (a, K

7. Description of Work:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M-1204-077-2A (PSG-354) and u ere permanently removed in accordance with DCP 2 6683.04SP. The rear brackets w ere left in-place. The removed snubbers were placed into the snubber rebuild program.

8. Tests Conducted: HB Pres: N!% Temp: N!%
,a

$v ,am sc.a 3 z.s

                                  ,.,,..r-
                                                . . , w a ,
                                                  .     . .r        %m  m.o     . n . .n -m r              . w uw . .                    a     =

i

                                                                                                          . o . ~,                   .m j

FORM NIS-2 (back) ]

9. Remarks : None.

w .u.u. = , m .s.n,a.n.a.a, CERTIFICATE OF COMPLIANCE O We certify that the statements made in the report are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Si6ned: 88 / Stmervisine ASME Codes Encine.g Date: y /95 Owner or Owher's Desicnee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Company (Factory Mutual Enrineerine A nociation) of Norn ood. Massachusetts have inspected the components described in this Owner's Report during the period

             /2/6/#/4            to      3/27/98              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of te ASME Code, Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manne(for any personal injury or property damage or a loss of any kind arising from or connected with this mspecfon. p

a. L- den Commissions California 67h inspector's Signature National Board, State, Prosince, and Endorsements Date a b b.

J' uo umanaxn

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requped 11 $r hmssons of the ASVE eede sectoaXI sh i s .ri

1. Owner: Southem Califomia Edison Company Unit : 2 2244 Walnut Grove Avenue MO: 94080325000

(( N Rosemead Califomia 91770 DCP: 2-6683.04SP Rspec : 062-94

2. Plant: San Onofre Nuclear Generating Station P&ID : 40113B San Clemente, Califcenia 92674-0128 N-5 : S2 1204-10
3. Work Performed by: Southern Califomia Edison Company T3pe Code Symbol Stamp: N/A Authorization No: N/A
4. Identi5 cation of System: Safety Injection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section IIL Class 2-NF.1974 Edition. S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
                                                                                                                                                                     ~
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Namesf NameOf Manufaaurer National Other Year Replaced or Code Component Manufaaurer Serial No. Board No. 1dersification Built Replacement Stamped Yes/No Mechanical Snubber Pacine Scientinc 3548 N/A S2S!077H012 1978 Replaced Yes PSA 1/4 23 5/16" Rigid Strut Lisega S2 SI-077-H-012 N/A RSO 0030-95 N/A Replacement No 3922RRIS

7. Description of Work:

/~T The mechanical snubber was replaced with a rigid stmt in accordance with DCP 2-6683.04SP. The existing attachment i ) brackets were reused. A VT 3 examination of the support assembly was performed after installation. De removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M 1204-077-2A (PSG-354) 1 l l l I l l I

8. Tests Conducted :UM Pres:N/A Temp:EB c) went .. >a m.s .rn a.o *m. , rw d, d.dm Samm.nm.c3mr .h ie ns e. pons a.d.d..anom.
3) een sheet a ownbeved end the sunnbe ershees a essere.d at th. 69 of cus % and (4) and sket a sWbehd and deed by es Owner as OmM desghet and the A1A.

FOIGI NIS-2 (b ck)

9. Remarks: None.

vppx.u msnu am x,pom w .n.u e O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonns to the rules of the ASME Code, Section XI. repair or replacement Type Code Syrnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: / / / 1 /_- - Sunenisine ASME Codes Encineer Date: /jf Oumer or 6wner's Designee. Title ' CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsuranee Comnanv (Factorv Mutual Enrineerine Associatlani of Norwood. Mass achusetts have inspected the components described in this Owner's Report during the period

              /2/l'7/94 to                 6//L-/95            . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken c'orrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, corretning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

nspecion. p. f Ot m tn C n Commissions California Ih7[

Inspector's Signature National Board, State, Province, and Endorsements Date 4/3 )'fh a wo: ecaos:sooo

7, .. _ _ . 5 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Reemred by tw Previsions orthe AshtE cede sectacL'o

                                                                  ,                                                           shem s .ri I,' Owner: Southem Califomia Edison Company                                                                            Unit: 2
.D.                      2244 Walnut Grove Avenue                                                                             MO: 94080388000 V                       Rosemead, California 91770 DCP: 2-6683.04SP 1

l Rspec: 061-94,

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40124B N-5: S2-1208 5 9 3.' Work Performed by: Southem Califamia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A 4.' identification of System: Chemical and Volume Control E91rationDate: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda }

l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Nameof . Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No.- Board No. Identification Built Reptacement Stamped Yes'No Mechanical Snubber - Pacific Scientific 36643 N/A' S2VC008H004 1984 Permanently Yes PSA 1/4 4 Deleted Mechanical Snubber Pacific Scientific 9280 N/A S2VC008H007 1980 Permanently No PSA 1/4 - 4 Deleted Mechanical Snubber Pacific Scientific 37409 N/A S2VC008H011 1986 Permanently No PSA 1/4 - 4 Deleted O' Mechanical Snubber PSA 1/4 - 4 Pacific Scientific 37402 N/A S2VC059H005 1986 Permanently Deleted No

7. Description of Work:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M 1208 008 2A (PSG 83) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left in-place. The removed snubbers were placed into the snubber rebuild program. , i i l

8. Tests Conducted:NM Pres:H/8 Temp:li%

O _ . ._ _ m _ ._.._....___m._,-.._ _.._ 3)ansk shem a ensnbered and tu amuhe .taheen a susseded si the tap .(eus im and (4) and stwas a .mented and doesd by the Owner a o mero demonse and the A1A.

 ?

FORM NIS-2 (b:ck)

9. Remarks
None.
                                                                % u.n-. - ,                  w.-,

O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this deletion confonnstothe rules of the ASME Code, Section XI. repair or repleement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: /N/ b Owmer or Dwner's Designee, Title Surmisine ASME Codes Encineer Date: 4'[i/96 CERTIFICATE OF INSPECTION ,, I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insuranee Companv /Factorv Mutual Encineerine Association) gf Norwood. Manachusetts have inspected the components described in this Owner's Report during the period

                 /M/94d                     to #M/99                      . and state that to the best of my knowledge and belief, the Owner has perfo/med' examinations and takefi cor(ective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection.

Inspecto'r's Signature /

                                             ,MAM                  Commissions             /M                         Califomia National Board, State, Province, and Endorsements Date f
                                     , 53 MO: a4080388000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Rapsed b #w Pwasiesof de AsME Cede SecnonM - sh.mi.fi p 1. Owner: Southern Califomia Edison Company Unit: 2 1 2244 Walnut Grove Avenue DCP: . 2-6683.04SP Rosemead,Cahfornia 91770 MO: 94080390000 Rspec: 062-94

2. Plant: San Onofre Nuclear Generating Station
                         ' San Clemente, California 92674-0128 P&ID: 40124B N-5:    S2 1208-5
3. Work Performed by: Southern CaliforniaEdison Company Type Code Symbol Stamp: N/A 1
4. Identification ofSystem: Chemical and Volume Control Authorization No: N/A Expiration Date: N/A
 -'   5. (a) Applicable Constmetion Code: ASME Section m. Class 2-NF.1974 Edition. S*74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of Name Of Manufacturer National other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Bulh Replacement Stamped Yes % Mechanical Snubber Pacific Scientific 36668 N/A S2VC008H029 1984 Replaced Yes PSA l/4 29" Rigid Strut Lisega S2 VC-008-H-029 N/A RSO OO30-95, N/A Replacement No 3922RR1S CCase N249, N71

7. DescriptionofWork:

The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT 3 examination of the support assembly was performed after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1208-008-2A (PSG-83) 9 4 l

8. Tests Conductm!: N/8 Pres: N!% Temp: N!%

koTE

  • _ . .

tal shens e the form of bein, skashek e enougs sney be used provided (1) aus s 8 I!2 et a il su C) siformonen a hems j Speigh 6 as the repon a puluded on each sheet . J;each shem s _ f and the numbat of sheet s tesorded es qhe top of pus fong and (4) sech sheet a smaeled and dated by tw Owner er Owners essense and tw AIA

4 FOIOi NIS-2 (back)

9. Remarks : None.

gAppw.moes Mwu steera m Arpone le be er.auwej *~ CERTIFICATE OF COMPLIANCE We cenify thist the statements made in the repon are correct and this confonnstothe mles rentacement of the ASME Code, Section XI. repair or replacement T3 pe Code Spnbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed; M8 IM Suoervisinc ASME Codes Encineer Date: 4 ins' Owner or Oumdr's Designee, Title CERTIFICATE OFINSPECTION I, the undersped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, and employed by A rkwricht MutualInsurance Comnany (Factorv Mutual Encineerine A s sociation) pf Norw cod. Mass achusetts have inspected the components desenbed in this Owner's Repen during the period

      /J?//9/9//--              to 4/3/#6                    , and state that to the best of my knowledge and belief, the Owner has perfofmedhaminations and tak'eiicorrfctive measures described in this Owner's Report in accordance with the requirements of te ASME Code Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any wananty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Repon. Funhennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection

                              //

inspect'or's$igrilittTe

                                > A<
                                    '            ~

Commissions /YM Califomia National Board, State, Province, and Endorsements Date . b7j $f e

 .m             .             .             _ __ .                      ..

i

  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS -

As Request h Ow Nvimens of the ASMICada SectonXI Sheet I of t

   ~js   1. Owner: Southern Califomia Edison Company                                                                                Unit: 2 2244 Walnut Grove Avenue                                                                                  DCP: 2-6683.04SP                                     ;

Rosemead, California 91770 MO: 94080391000 Rspec: 064-94

2. Plant: San Onofre Nuclear Generating Station pgIp;. 40124B '

t

  • San Clemente, California 92674-0128 N-5: S2-1208-5
       ; 3 Work Performed by:             Southem Califomia Edison Company Type Code Spnbol Stamp: N/A '

e 4. Identification ofSystem: Chemical and Volume Control Authorization No: N/A Expiration Date: N/A i

                                                                                                                                                                                       -(
5. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition. S'74 AdAman. Code Cue: None t (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda l
6. Identification of Components Repaired or Replaced and Replacement Components: .

Repaired. ASME Name of Name Of Manufacturer National Other Year Replaced or ' Code Component Manufacturer Serial No. Board No. Identification Built . Replacement Siamped

                                                                                                                                                                             - Yes/No 2' Pipe Guide                Grinnell Supply            Ht. Code B-086                      N/A          RSO 1414-94,                       N/A Replacement               No SA-36
7. Description of Work:'

The pipe support was modified in accordance with DCP 2-6683.04SP by replacing the u-bolt with a 2' pipe guide.

Reference:

Stress Calculation M 1208-008-2A (PSG-83) ' t i. 9 5 i

8. Tests Conducted: E!A Pres: H% Temp: H%  ;

i k  !

        - - 3;e   . shews
                      - a.r                            . w    - d ,.~.d n, e . . . . l m m - -                               .-,.-g,..e,-.--~                                        :
                                 ^ an d au asnhar of newem a scanded at the top of the som and (4) each sheet s see.i.d mid emed by the owns . Owners desense and the A1A l

FORM NIS-2 (baek)

9. Remarks : None, ma u uas mm ~, .,

CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this repiscement conforms to the rules of the ASME Code, Section XI. repair or replacement TyJe Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: [M Oiner or Ow'ner's Designee, Title Surervisine ASNE Codes Encineer Date: 4/[/tX CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California, and employed by Arkwricht Mutual Insurance Company (Factorv Mutual Eneincerine A ssociationlof Norn ood. Massschusetts have inspected the components described in this Owner's Repon during the period

          ///4/M                  to /4/AAPd7                   . and state that to the best of my knowledge and belief, the Owner has perf6rmed examinations and tak(n' cor'rective measures described in this Owner's Repon in accordance with the requirements of le ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repen. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection. [ #)eh ' Commissions /Wd California inspector's Signanv6 National Board, State, Province, and Endorsements l Date 02 _ 42P [ 1 I f i e IM

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS '

4. ne a >r ew h daw ASME Code SatmM +

Sheet I of, '

l. Oner: Southern CaliforniaEdison Company Unit: 2
       ,W                         2244 Walnut Grove Avenue                                                                  MO: 94080394000
   ;( )                           Rosemead, California 91770 DCP: 2-6683.04SP                               '

Rspec: N/A

             ' 2. Plant:          San Onofre Nuclear Generating Station
                               , San Clemente, California 92674-0128 P&ID: 40124B N-5: S2 1208-5                                 ,

L

3. WorkPerformedby: Southem California Edison Company ,

Type Code SpnbolStamp: N/A

4. Identification of System: Chemical and Volume Control . AuthorizationNo: N/A [
                                                                                                                        . Expiration Date:               N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case: None O (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: -

1 Repaired. ASME Name.of Name of Manufacturer Nadonal Other Year Replaced or Code cm, - - Manufacturer Serial No. Board No. Identificanon Built Replacement Stamped . t YesS'o Pipe Guide --- ---- N/A S2VC008H042 N/A Pennanently No Deleted

7. DescriptionofWork: '

The pipe guide was no longer required per the latest pipe stress calculation M 1208-008-2A (PSG-83) and was permanently removed in accordance with DCP 2-6683.04SP. v  ; I i t l i i

8. Tests Conducted: N% Pres: N% Temp: Ne j l
   .                                                                                                                                                                         l

_.-.,___h.__.....,_._,._e,.__.__ 3)each shee s and the aanha of shout a sumerd a the sep ef sm W and (d)each ahee a estaled and eued by Ow owns or Ommers emmense and tw M 4

r FORM NIS-2 (b:ck)

9. Remarks : None.

mome.,<, moom w .w,, CERTIFICATE OF COMPLIANCE O We certify that the statements made in the report are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: # *

                                    -   /./ #             Supervisine ASME Codes Encineer                Date:                M[

Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comoany (Factory Mutual Enrineerine A s5ociation) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period

           .2/g9/9C to #/#/99                                     , and state that to the best of my knowledge and belief, the Owner has perforined ex'aminations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desenbed in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. k r /}7//22dA 77 Commissions l$$ Califamia insp'ctor's e Signature / National Board, State, Prosince, and Endorsements Date M 8, MN

               /

uo: uososuooo

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A.a. m e. % .rm.Asure s m Sh t i orI

,m     1. Chvner: Southern California Edison Company                                                 Unit: 2

( ) 2244 Walnut Grove Avenue MO: 94080395000 d Rosemead,Califomia 91770 DCP: 2-6683.04SP Rspec: 062-94

2. Plant: San Onofre Nuclear Generating Station PB@: 40124B San Clemente, Califamia 92674-0128 N-5: S2-1218-2
3. Work Performed by: Southem California Edison Company Type Code SymbolStamp: N/A
4. Identification of System: Chemical and Volume Control Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Construction Code: AShE Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: ,
                     .                                                                                                  Repaired,    ASME Name of                 Name Of           Manufacturer      National         Other              Year   Replaced or    Code Component               Manufacturer         Serial No.      Board No.      Identification        Built  Replaecment  Stamped Yes'No Mechanica1 Snubber         Pacific Scientific   1580                   N/A       S2BM037H004              1977   Replaced       Yes PSA l/2                                                                                                                                      '

9 3/8" Rigid Strut Lisega S2-BM-037 H-004 N/A RSO 0030-95, N/A Replacement No 3922RRIS CCase N249, N71 p 7. DescriptionofWork: (*j The mechanical snubber was replaced with a rigid simt in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT-3 examination of the support assembly was performed after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1218-037 2A (PSG-84) I l l i 1 1 1

8. Tests Conducted: N!A Pres: N/A Temp: M I l v  !

wra se4 r .r o n..* *,. a a u . ~ w .u ..r% . .. .r m% m. m.si.a am.an c3.r or~ . o in w .

                                                                                                                  .,        m                        I

FORM NIS-2 (back)  !

9. Remarks: None.

ma mn.au,awa 6..u ca at CERTIFICATE OF COMPLIANCE I We cenify that the statements made in the report are correct and this renlacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: [M /t< -- Sunervisine ASME Codes Encineer Date: h/96 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION , I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Company (Factory Mutual Encineerine s Association) of Norwood. Massachusetts) ave inspected the components described in this Owner's Repon during the period AC//9/9(4 to #/#/#f . and state that to the best ofmy knowledge and belief, the Owner has perforined eicaminations and taketicorrective measures described in this Outer's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injtuy or propeny damage or a loss of any kind arising from or connected with this mspection.

                            &d%4cv                        Commissions         /8MM                         California inspector's Signature /                                         National Board, State, Province, and Endorsements Datehf}2Yt,l, /Wf
             /

e =nomooo

                                                                                                                                     /

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regeed by cie Prms.es of the ASME Ce<le 5 rtws\1 Sheet i eri

1. Ovmer: Southern California Edison Company Unit : 2 m 2244 Walnut Grove Avenue MO: 94080491000

(") Rosemead,Califomia 91770 DCP : 2-6683.04SP Rspec : 062-94

                                                                                                                                                                   +
2. Plant: San Onofre Nuclear Generating Station P&ID : 40112B San Clemente, California 92674-0128 N-5 : S2 1219-3
3. Work Performed by: Southern California Edison Company Type Code S3 Tnbol Stamp: N/A Authorization No: N/A
4. Identification of System: Refueling Water Tanks bpiration Date: N/A
5. (a) Applicable Constmction Code: ASME Section III. Class 2 NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addend 3
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Nameof Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 1605 N/A S2FS057H075 1977 Replaced Yes PSA 1-4 141/2* Rigid Strut Lisega S2-FS-057-H-075 N/A RS0 0030-95 N/A Replacement No 3932RRIS Mechanical Snubber Pacific Scientific 20360 N/A S2FS057H078 1986 Replaced No PSA 1/2 O 101/16' Rigid Strut Lisega S2-FS-057 H-078 N/A RSO 0030-95 N/A Replacement ( /) 3922RRIS . No

7. Description of Work:

The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. Existing attachment brackets were reused. VT-3 examinations of the suppen assemblies were performed after installation. The removed snubbers were placed into the snubber rebuild program.

Reference:

Stress Calculation M-1218-037 2A (PSG-84)

8. Tests Conducted :N_% Pres :NM Temp:N_%

O , NCrrt.

  • 2 shesen in the issm efhsis,0.c4 er dremings sney be used pemedad (t)aus a 8 le sh a in A o)mforrnseca an herns 3 oveush 4 en the report s inclut
3) each ehsei e surnbered and ou menbar afsheet is seseded silhe esp of ihn form, and (d)each shese is sunnled and Anied by the Ommer er Owners des] -

FORM NIS-2 (b:ck)

9. Remarks : None.

I m,, u.~w x, w w a .w.a, f CERTIFIC/ TE OF COMPLIANCE We cenify that the statements made in the report are correct and this renlacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Spnbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: I Owner or Owner's Designee, Title Suoervisinc ASME codes Encineer Date: +///96

                                                                                                                      '/ '

CERTIFICATE OFINSPECTION , I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comnany (Factorv Mutual Encineerine Association) of Norwood. Maisachusetts b ve inspected the components described in this Owner's Repon during the period

             /#//894                 to #/6             ~

_ C . and state that to the kst of rny knowledge and belief, the Owner has perforfned (xaminations and taker (correftive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this aispection. [ Afh ' Commissions /d%2_ Califomia Inspector's 'Signatsre / National Board, State, Province, and Endorsements Date / h81 /eS Nh - A MO ; 64060a91000

m -

                                  * - FORM NIS-2 OWNER'S                              REPORT As seguired                   FOR byihs ,reisions of        REPAIRS the ASME Code seenier,xi   OR REPLACEMENTS :

ShesiI orI

1. Owner: Souibern California Edison Company Unit: 2 .;
    ,q
     ,                              2244 Walnut Grove Avenue'                                                                                  DCP: 2-6683.04SP 1        4                      Rosemend, Califomia ' 91770 -                                                                               MO:        94080494000

'Af Rspec 06194 l

                . 2. Plant:        San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40112B 3                        ,

N 5: S2-1219-3

3. Work Perfonned by: Southern Califomia Edison Company 1 Type Code Symbol Stamp: N/A
4. Identification of System: Refueling Water Tarls Authorization No: N/A ,

Expiration Date: 'N/A j

5. (a) Applicable Construction Code: ASME Section 11L Class 2-NF.1974 Edition. S'74 AMawls Code Cae None . _

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components: -

Repaired. -ASME . Nagor Name of ,. Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yest,o Variable Spring Grinnell Supply S2-FS-057.H-074 N/A S2FS057H074 N/A Permanently No Hanser Deleted

7. Description of Work: -

The spring hanger was no longer required per the latest pipe stress calculation M 1218-037-2A (PSG-84) and was permanently removed in accordance with DCP 2-6683.04SP. i 4 l I h

8. Tests Conducted: Na Pres: N!% Temp: N_n

(' 's mnt .. us . s .rwo e . ws .or w d e d.d m.- n = = n ni m re .e. . iis I ih,.seh s = e. is,-i = **.d d =-ham i.

3) eneh sheet a musee.ed and the numbes of shavis a sneerded er ihn lap of een fers and M) each abs. a seemisd and essed by the Owner er Owners deignee and e.e A1A.

a

3 FORM NIS-2 (b:ck) l

9. Remarks : None. 4 l

wna., mm. w.m u, .aam CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement T3pe Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed. M8 d --- Sunervisine ASME Codes Encineer Date: d((95 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arlewricht Mutual Insurance Companv (Factorv Mutual Enrineerine Association) of Nom ood. Mas sschusetts have inspected the components described in this Owner's Report during the period

               /2 /6 /74           to     3/B7/95
                                             ~
                                                                 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Oner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Omer's Report. Furthermore, neither the Inspector nor his employer shall be liably in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspecfion. . (

                  'CL          -

C42km Commissions Ca!ifornia I6k Inspector's Signature National Board, State Province, and Endorsements Date YKL b JI A uo uosuuwo &

FORM NIS-2 OWNER'S un REPORT FOR REPAIRS OR REPLACEMENTS di,ye.p r..re.4 sus c.d.s_.n:o si .r

1. Oner: Southern Califomia Edison Company Unit: 2
 ,                        2244 Walnut Grove Avenue                                                                   MO:       94080498000 Rosemead, California 91770 (mV)                                                                                                                DCP: 2-6683.04SP Rspec: 061 94
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40123A N-5: S2-1208-3
3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A
4. Identification of System: Chemical and Volume Control Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2 NF.1974 Edition S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repa: red, ASME Name.f NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes % Mechanical Snubber Pacific Scientific 3975 N/A S2VC012H007 1977 Permanently Yes PSA 1/4 - 4 Deleted

7. Description of Work:
          'Ihe mechanical snubber with attachment hardware was no longer required per the latest pipe stress calculation M-1208 003 AA (PSG 142) and was permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were o        left in-place. The removed snubber was placed into the snubber rebuild program.
8. Tests Conducted: N/% Pres: E/% Temp: N/%

(" (- ) - , _ . - ., _ . _ _ ..,_ .... _ _ _ , _ ._ _ .. _ d _, -

3) each them a namnbeved and Du awnbe of sheets a secorded at on top ofihm form, and (4) each shees b .unnled and dated by du Owns er Owners desense and ou AW

FORM NIS-2 (back)

                                                                                                                                ~
9. Remarks : None.
                                                                 =w-         - - .a mpon. % .=,

e O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this deletion conforms to the rules of the ASME Code, Section XI. repair or replacement T3pe Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: 4 l Sur>ervisine ASME Codes Eneineer Date: f f Outer or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arlorricht MutualInsurance Company (Factorv Mutual Encineerine Anociation)/of

                     /d/7 94Nornood. Mass achusetts pave inspected the components described in this Owner's Report d to .#/#fGM . and state that to the best ofmy knowledge and belief, the Oumer has performed examina'tions and taken'corre6tive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. _, [ Ah Commissions /[4$2 California Inspector's Signature / National Board, State. Province, and Endorsements Date$j t/ )WT '

                      /                                                                                                                           i e -mm

T FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regared by Ow PresinW cf ew ASMs Code Secton.\1 Sheet i ofi

1. Oner- Southern California Edison Company Unit: 2 7- 2244 Walnut Grove Avenue DCP: 2-6683.04SP

( ) Rosemesd,Califomia 91770 MO: 94080499000 Rspec: 062-94

2. Plant: San Ono&e Nuclear Generating StaSt PalD: 40123A San Clemente, California 92674-0128 N-5: S2-1208-3
3. Work Performed by: Southern Califonua Edison Company Type Code Symbol Stamp: N/A
4. Identification of System: Chemical and Volume Control Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Constzvetion Code: ASME Section 111. Class 2-NF.1974 Edition. S'74 Addenda. Code Case None -

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASKfE Nameof NameOf hianufacturer National O'her

                                                                                                                                            .                 Year        Replaced or      Code Component                       hfanufacturer                        Serial No.                Board No.             Identification           Built      Replacement      Stamped Yes/No Mechanical Snubber                 Pacific Scientific              4256                                    N/A         S2VC003H019E                   1978         Replaced          Yes PSA 1-4 451/4" Rigid Strut                 Lisega                          S2-VC-003-H019                          N/A         RSO 0030-95,                   N/A Replacement                No 3932RRI                                             CCase N249, N71 Mechanical Snubber                 Pacific Scientific              5367                                    N/A         S2VC003H019W                   1979         Replaced          Yes PSA 1-4
 /~'1  251/2* Rigid strut                 Lisega                          S2-VC 003-H019,                         N/A         RS0 0030-95,                   N/A Replacement                No V                                                                        3932RR1                                             CCase N249, N71
7. Description of Work:

The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. VT 3 examinations of the suppon assemblies were performed after installation. The removed snubbers were placed into the snubber rebuild program.

Reference:

Stress Calculation M-1208-003 AA (PSG-142)

8. Tests Conducted: U!% Pres: U1% Temp: N.18 m

a hoTL supplemensat shree m du fann ofhsta. aheid% or dmwenys mey be used povukd(1) mar s 8 t/2 m a la m o) mformenon a harns 1 through 6 on ihm repen a mcluded on each sheet

               )) each ehsei e nurnbeved and Ow nurnbar of steert a recorded at the tap of the form, and (4) sech sheet a synekd and dened by Ow Owner er Owners desq;new and Og A1A.

FORM NIS-2 (b:ck)

9. Remarks : None.

m--~wa, m.m .a m> CERTIFICATE OF COMPLIANCE 0 We certify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: < Sunenisine ASME Codes Encineer Date: / 86 Owner or Owner's Designee, Title CERTIFICATE OF INSFECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwright Mutual Insurance Company Wactorv Mutual Encineerine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period N// /6/94 to 3 /2 8/'76 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neiL me Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and correctiv .neasures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner ror any personal injury or property damage or a loss of any kind arising from or connected with this mspection. Ocut. n Commissions Califomia 157f Inspector's Signature National Board, State, Prosince, and Endorsements Date k$f05 , Mo. 64080e99000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.no. d>> w.ms eewAmre.4,se.cos sa..o ri m

1. O w ner: Southem Califomia Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 940S0596000

(") Rosemead,Califomia 91770 DCP: 2-6683.04SP Rspec: 061 94

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40112C N 5: S2-1204-11
3. Work Performed by: Southem Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name.of Name of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No, Identification Built Replacement Stamped Yes% Mechanical Snubber Pacific Scientific 36640 N/A S2S1021H0ll 1984 Permanently Yes PSA 1/4 Deletet Mechanical Snubber Pacific Scientific 3091 N/A S2S1021H014 1978 Permar.cntly Yes PSA 1-4 Deleted Mechanical Snubber Pacific Scientific 8092 N/A S2S1021H017 1979 Permanently Yes PSA 3 5 Deleted r3 Mechanical Snubber. Pacific Scientific 3346 N/A S2S1021H021 1977 Pennanently i I Yes PSA 3-5 - Deleted Mechanical Snubber Pacific Scientific 3948 N/A S2S1021H023 1977 Permanently Yes PSA I/4 Deleted Mechanical Snubber Pacific Scientific 280 N/A S2S1021H031 1979 Permanently Yes PSA18 Deleted

7. Description of Work:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M-1204-021 2A (PSG-247) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left in-place. The removed snubbers were placed into the snubber rebuild program.

8. Tests Conducted :HB Pres :H% Temp:H!%

(O \ ) NOTE: L, , J shoem as on farm erIsm,ahnshu,e - ,. sney be med prended (1)au a 8 VJ m a a l m, C)mformniien in hems I #wough 6 en se repen is included on each

3) each sheet a manbeid and su numbs of sheets is sensedid an On top of om imm, and (4) ensb sheet is runohd and ested by on Denner or Dwna4 designes and Ow I

J

y_ FORM NIS-2 (beck)

9. Remarks: None.

w.u uua,- e a auw, O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: _ I<b Owner or Owner's Designee, Title Supervisine ASME Codes Encineer Date: 4 95I CERTIF]CATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by Arkwriebt Mutua! Insurance Comnanv (Factory Mutual Enrineerine A ssociation) of Norwood. Massmehuseng have inspected the components desenbed in this Owner's Report during the period

           / M S #'~C to WWW . and state that to the best of tny knowledge and belief, the Oumer has perfofmed 6xaminations and takericorr(ctive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X].

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in this Owmer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. hh inspector's Signature / Commissions /8M California National Board, State, Province, and Endorsements . l Date 8,h 3, /.6.tPS~ . i Mo: 94000$96000

     ,o    ,
                                                                                                                                                                                       ., )

<?-

           ,                          ' FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Resed b edmW of k ASME Cods SmM
                                                                                                                                                                                ,         )j Shees I of1
                '). Ouver: Southern Califomia Edison Company                                                              Unit: 2 I("} :-                         2244 Walnut Grove Avenue                                                              MO:          94080597000                                         1

(/ Rosemead, California . 91770 DCP: 2 6683.04SP Repec: 061-94

               - 2. Plant:          San Onofre Nuclear Generating Station                                                                                                                  '
                                  . San Clemente Califomia 92674-0128 P&ID: 40112C N 5: : S2 1204 1 I .

3.- Work Performed by: Southem California Edison Company - Type Code Symbol Stamp: N/A Authorization No: N/A

4. Identification of System: Safetyinjection and Shutdown Cooling Expiration Date: N/A ,
             - 5. (a) Applicable Construction Code: ASME Section Ill. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None
                   . (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Nannf . Name Of Manufacturer National Other Yest Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped , YesSo ' MechanicalSnubber Pacific Scientific 36787 N/A S2Sil46H004N 1985 Permanently No l PSA 1/4 Deleted i Mechanical Snubber Pacific Scientific 36704 N/A S2Sil46H004S 1984 Permanently Yes > PSA 1/4 Deleted  ! Mechanical Snubber Pacific Scientific 3682 N/A S2Sil64H005 1978 Permanently Yes l PSA 1-4 Deleted ~ O, 7. DescriptionofWork: . The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M 1204-021 2A (PSG 247) and were permanently removed in accordance with DCP 2-6683.04 SP. The rear brackets were lea in-place. The removed snubbers were placed into the snubber rebuild program. l h i i

8. Tests Conducted:HB Pres:He Temp:N/8 ,

1 l Q,C\ won: .. -' a m . o. f.ne .r>=. ama *=, r 6. m.4 si d.d (i) . : va in 31.% a) hf . m i e ,.n in nsius.d n ch in t 3)ene aest s amabared and k asubu af sheen a receseed elIhs top of tus fang und (d)ema ahea aOwner's sineled and dened desgnes by tw osmer. n a en ih and an AIA, 6

o FORM NIS-2 (b;ck)

9. Remarks: None.
      ~

w uuwm w w e a.a.,s 9, CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: 8MdII--- Owner or Owner's Desienee Title Sutiervisine ASME Codes Encineer Date: f///$6 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Californ:n. and employed by Arkwricht Mutual Insurance Company &actorv Mutual Encineerine Anociation) of Norwood. Massschusetts have inspected the components described in this Owner's Report during the period

                /2/OSNf to G//5/95                               . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certifVate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Impcctor nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this 315Pecti

                     'CL            hh3           O        Commissions                                       Califomia 1574 Inspector's Signature                                          National Board, State, Provmce, and Endorsements Date       b b SS i          7

E FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEM ENTS A, n.eAd w e. ,rm .rn= mr e.d. s.e '

                    ~                                                                                            sheet 3 ofI                                                '

l.- Osmer: Southern California Edison Company , Unit : 2 2244 Walnut Grove Avenue MO: 94080956000  ; Rosemead, California 91770 DCP: 2-6683.04SP Rspec : 061-94

2. Plant: San Onofre Nuclear Generating Station P&ID : 40112C -

San Clemente, California 92674-0128 N-5: S2-1204-11

3. WorkPerformedby: Southern California Edison Company Type Code Symbolstamp: N/A  ;

Authorization No: N/A

4. Identification ofSystem: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 AAAmin Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Narruf NameOf- Manurscrurer National other Year Replaced or Code component Manufacturer Serial No. Board No. Identification Built Replacement Nmped Yes/No Spring Support Grinnell S2 SI-021-H-013 N/A S2SIO21H013 N/A Permanently Assembly No Deleted '  !

7. Description of Work:

i The spring support assembly was no longer required and was permanently removed in accordance with DCP 2-6683.04SP. '

Reference:

M-1204 021-2A(PSG 247) i 4 i 1 i i l l

                                                                                                                                                                             ?

l

8. Tests Conducted :E n Pres:N% Temp:E!%

r

                                                                                                                                                                           .l mnt - . .          ;     . . s .rs a a .              , s. d ,,.ed.d m - 6 m . a. m we
                                                                                                         .e w i = n d -                         .e,.,i = a d . a a
3) sech thsel a membeed and $w mesnha af abase e reuseded at $w tap a(Suis foren, and (4) ask aben b beenhd and ented by tw Ommer er O.mers esegnes and tu A

y FORM NIS-2 (b:ck)

9. Remarks : None.

m -.a. v.u.p.m .caa . CER TIFICATE OF COMPI. LANCE O We cenify that the statements made in the report are c wrect and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: /[ Owser or Ow'ner's Designee, Title Stmervisine ASME Codes Eneineer Date: f!/ JI CERTIFICATE OFINSPECTION I, the undersigned holding a valid cormnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutus'Insu rance Comnany (Factorv Mutual Enrineerine A ssociatior0 of Norwood. Massschusetts have inspected the components desenbed in this Owner's Report during the period A9/A9/47# to 4 4/. S A $P S . and state that to the best of my knowledge and belief, the Owner has perforded exlimiriations and 'takeTi cor(ective measures described in this Owner's Repan in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. ma24r>r- Commissions /gM California inspector's Signatut National Board, State, Prosince, and Endorsements Dats by c_R s@C

            /                                                                                                                          ,

i l l N: e4

                              - FORM NIS-2 OWNER'S                             REPORT FOR REPAIRS OR REPLACEMENTS A.m =dby= p,=

t

                                                                                                   .rn.Asm ca.s e x Sheet 1 or 8 -
1. Owner Southern California Edison Company Unit: 2.

G- 2244 Walnut Grove Avenue MO: 94080999000 Rosemead, California 91770 DCP: 2-6683.04SP Rspec: 06194 i

2. Plant: San Onofre Nuclear Generating Station
                          ' San Clemente, California 92674-0128 P&ID : 40124B N-5 : S2 1208-5
3. WorkPerformedby: Southern California Edison Company T3pe Code Symbol Stamp: N/A '

At:thorization No: N/A l

4. Identification of System: SafetyInjection and Shutdown Cooling ' ExpirationDate: N/A' i
5. (a) Applicable Construction Code: ASME Section 11L Class 2-NF.1974 Edition. S'74 AAAmda Code Case: None *

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda  ;

      . 6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME - Name*of Name Of Manufacturer Nanonal OGwr Year Replaced or Code Component Manufacturer Seria! No. Board No. Idendfication Built Replacement Stamped  ! YesWo Traverse Pipe Stop Bechtel N/A N/A S2VC058H035 N/A Permanently No  ! C.S. Deleted  ! i

7. DescriptionofWork:

The pipe guide was no longer required per the latest pipe stress analysis M-1204-021-2A (PSG-247) and was permanently I removed in accordance with DCP 2-6683.04SP. i l I l

                                                                                                                                                                                       'l l

I

8. Tests Conducted :N!% Pres:S!% Temp:NB won s.. ;as . a. s amma.4=h . y 6. 4,,eme.d m.= = s n m a n m.m mr== .i m i n.ush e = a= =p a = =ch.dd = =* *=t.

3)nch sheet n -

                                     ? and the au-bar of abesin a smerted at to top of aus form. and g)each sheeta sonded and deaed by the owner er ownen desqpws and the A1A.

FOR.TI NIS-2 (back)

9. Remarks : None.

an.w. u.:.me, w n,.n w .wa, CERTIFICATE OF COMFLIANCE O We cenify that the statements made in the repon are correct and this deletion confonnstothe rules of the ASME Code. Section XI. repair or replacement T3pe Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: // v2 5 , Supenisine ASME Codes Encineer Date: 9/[95' Ouner or Ow'ner's Desicnee, Title CERTIFICATE OF INSPECTION I, the undersigned hoi [!ing a valid commission issued by the National Board ofBoiler and Pressure Vesse! Inspect or Province 6f California. and employed by Arkwricht Mutus1 Insurance Com.nanv fFactorv Mutual Encineerine A ssociation) of Norwood. Massachusetts hjve inspected the components described in this Owner's Repon during the period

       /MM#4                  to 4/4/9W . and state that to the best of my knowledge and belief, the Owner has perforffied c'xaminations and taken'conective measures described in this Owner's Repon in accordance with the requirements te ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warran:y, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. madh Commissions /84 Califomia Inspector's Signature / ' Natiorial Board, State, Province, and Endorsements Date&, rs

         -               , fM

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENIS asmag.h.aby men-im ersheasmc desad ex I l

       ~
 't        \                                                                                                                                               i j                                                                                                   Sheet 1 of1                                   i
1. Owner: Southern California Edison Company Unit: 2 l 2244 Walnut Grme Avenue, th. CA 91770 MO: 94081017 j
             ,                                                                                               RS:         04S-94                            !
2. Plant: San Onofic Nudcar Cencrating Station P&ID: 40111B (E-4)

P.O. Box 128, San Clemente, CA 92674 4128 N-5: N/A

3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A 1
4. Identification of System: Reactor Coolant Expiradon Date: N/A S. (a) Applicable Construedon Code: ASME Secnon III, Cass 2,1974 Edition, S'74 N, Code Cases: None l (b) Applicable Edition of Secdon XI Utilized for Repairs or Replacemenu: 1989 Edition, No Addenda
6. Identificadon of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer Nadonal Other Year Replaced, or Code Component Manufacturer Sedal No. Board No. Identificadon Built Replacement Stamped Yet/No W Union Tube Parker Hannifin Trace Code UBAE N/A Downstream of N/A Replacement No S21201MR042 RSO 3028-93 SA-213, Gr 316

7. Description of Work:

O The tube fitting downstream of S21201MR042 was found leaking at a compression connection joint and was replaced.

8. Tests Conducted: System Irakage [ ] System Funcdonal [X] System Insemce [ ] Hydrostatic [] Pneumatic [ ] Other [ ]
  • Pressure: 2260 psig Temp: N/A
     ,s~ ~

k

     \

Note: Supplernental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information in Items 1 through 6 on this report is included on each sheet, (3) each sheet is numbered and the number of sheets is tycorded at the top of this form, and (4) each sheet is initialed and dated by the Owner or Owner's designee and the AIA.

FORM NIS-2 (back) 1

9. Remarks: None
                                                                                                                                          ]

(Applicable Manufacturer's Data Reports to be attached) l CERTIFICATE OF COMPLIANCE I We certify that the statements made in the report are correct and this nelamment conforms to the rules of the ASME Code, Seedon XI. Type Code Symbol Stamp: N/A Certificate of Authorizadon No: N/A Expiration Date: N/A signed: Owner or Owner's Designee, Title

                                                            .Sutervisine ASME Codes Enrineer            Date:        // !I k .19 M CERT 1FICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspecton and the State or Province of California. and employed by Arkwriebt Mutual Insurance Company (Factory Murual EnMneerint AMtion) of Norwood. Massachusetts have ins         ed * . ponents described in this Owner's Report during the period GI/N/642               to /         .8            . and state that to the best of my knowledge and belief, the Owner has performed examinations and talen corfective measures described in this Owncfs Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correedve measures described in this owners Report. Furthermore, neither the Inspector nor his employer shall - be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                     -LA4)W2d/>f
          ~1nspect' ors Signatude Commissions       l$b0                        California (National Board, State, Province, and Endorsements }

Date # 19

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u n.,-4 w e. en-.ms ofhe ASME cede SansM m 1. Owner: Southem Califomia Edison Company Unit: 2 lV T 2244 Walnut Grove Avenue Rosemead, California 91770 MO: 94081166000 FCN: F10906M Rspec : 049-95

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califorma 92674-0128 P&ID: 40134A E-8 N-5: S2-1212-13
3. WorkPerformedby: Southern Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Nuclear Plant Sampling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'75 Addenda. Code Cases: Nong (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped - Yes'No 3/4" Globe Valve Rockwell RA937 N/A S21212MR073 1977 - Yes Intemational Disc Rockwell Heat H3584 N/A RSO 2-P-1448-81, N/A Replacement No International SA567 Gr.1 ,m

7. Description of Work-The valve was disassembled for rework due to seat leakage, this required the removal of the body-to-bonnet seal weld. The valve was reassembled after replacing the valve disc. Weld record WR2-95-169 and FCN F10906M were used to re-seal weld the body-to-bonnet joint. A PT examination was performed on the new seal weld.
8. Tests Conducted: System Functional Pressure Test Pres: 2250 nsia Temp: N_/A 3

(G_ p Wh 5 QM W $

FORM NIS-2 (b:ck)

9. Remarks : A dass 1 valve is currently installed in a class 2 system, as allowed by ASME III, paragraph NCA 2134 w,-- % no.a.pw==w.nua.e CERTIFICAIE OF COMPLIANCE We cemfy that the statements made in the repo:t are correct and this renlacement conformstotherules of the ASME Code, Section XI. repair er rn ramment Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed:

OwnerorOwner'sDesignee Title Suoervisine ASME Codes Entineer Date: 8/:7 5 CERTIFICATE OFINSPECTION

                                                                    ~

I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of Californla. and employed by 4 rkwricht Mutual Insurance Comnanv (Factorv Mutual Eneineerine Association) of Norwood, Massachusetts have inspected the components described in this Oser's Report during the period _3/4/QS to M / 7 4 T . and state that to the best ofmy knowledge and belief, the Owner has perfo'rmed examinations and'taken corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thisin tion.

                            /hrf/2d M                    Commissions /MS                            Califomia                               i Inspector's Signature /                                     National Board, State, Province, and Endorsements va,. w y .         .

ms  : 1 i e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u hei-w hv e. ei .re. asur e.d. -x ss.n i .c: i

1. Owner! Southem California Edison Company Unit: 2 s -

2244 Walnut Grove Avenue O MO: 94081552000 Rosemead, California 91770 t DCP: 2-6683.04SP [ 2.' Plant:' Rspec: 061-94 i San Onofre Nuclear Generating Station San Clemente, California 92674-0128 PAID: 40112A  ! N-5: S2 1204 34 l 3 WorkPerformedby: Southem Califomia Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A .  !

4. ' Identification of System: Safety Injection and Shutdown Cooling Expiration Date: N/A  :
5. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF_1974 Edition S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name,of Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 2556 N/A S2SIO48H004 1977 Permanently Yes PSA 1/4-4 Deleted Mechanical Snubber Pacific Scient fic 37398 N/A S2S1048H007 1986 Permanently No PSA I/4-4 Deleted ' Mechanical Snubber Pacific Scientific 3678 N/A S2S1049H003 1978 Permanently Yes = l PSA 1/2 -21/2 Deleted - Mechamcal Snubber Pactfic Scientific 20364 N/A S2Sil86H001 1986 Permanently No . PSA 1/2 - 21/2 Deleted - l

7. Description of Work:

i The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation . M-1204 014-4A (PSG 7) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left j in. place. Tbe removed snubbers were placed into the snubber rebuild program. ' I h i l

8. Tests Conducted :MS Pres:N M Temp:lle mnt s.. - a.n. e.s.-arm ama . 16 i d, d m== s e m a = n m.m w. ==== n=== i e w == es =paa e sia d d = ==h
  • a, -
3) each shesi e nienbered and te number erahesis e amanted as tu tup ares W and F)esh shoes a svented and ented by as owns er Ws emignee and 9. &

FORM NIS-2 (b:ck)

9. Remarks : None.
                                                         - u.nuo-. - - .w                  ,

CERTIFICATE OF COMPLIANCE O We cenify that the statements made in the repon are correct and this deletion conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: # Sunenisine ASME Codes Encineer Date: [ ' M Oumer or' Owner's Designee. Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel !nspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnany (Factorv Mutual Encineerine Association) of Norwood. Massschusetts have inspected the components described in this Owner's Report during the period

           / M 6' M~ P #             to /M/PS . and state that to the best of my knowledge and belief, the Owmer has perforfneilfxaminations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennore, neither the Inspector nor his employer shall be liable in r.r., .aanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                 /             mfd 24+t                     Commissions       #O                              California inspector's Signature #                                        National Board, State, Prosince, and Endorsements Date     /
                            $ bNS Wo ' 94001552000                                                                                                                       9  i l

l l

        '..                       FORM NIS-2 OWNER'S                REPORT FOR REPAIRS OR REPLACEMENTS -

A a.c.e4i.ye %.fe. Asur e.d.s.e axi

  • sheet I of a
1. Owner: Southern Califomia Edison Company Unit : 2-
 .'-N                           2244 Walnut Grove Avenue                                                     MO: 94081553000 L                       Rosemead,Cahfomia ~ 91770
      '                                                                                                      DCP: 2-6683.04SP Rspec : 062-94
             ' 2 Plant:         San Onofre Nuclear Generating Station -
                              . San Clemente, Califomia 92674-0128                                           P&ID: 40112A l N-5: S2-1204-34
3. WorkPerfonnedby: Southem Califomia Edison Company Type Code Spnbolstamp: N/A Authorization No: N/A
4. Identifwation of System: Safety Injection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2 h'F.1974 Edition. S*74 Addenda. Code Case None
                ' (b) Applicable Edition cf Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. - Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Nameof Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesNo Mechanical Snubber Pacific Scientific 1587 N/A S2S1053H003 1977 Replaced Yes PSA 1/2 - 21/2 9 3/8" Rigid strut Lisega S2-SI-053-H-003 N/A RSO OO30-95 N/A Replacement No 3922RRIS

7. Description of Woik:

The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT 3 examination of the suppen assembly was performed after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M 1204-014-4A (PSG-7)

8. Tests Conducted :M/A Pres:N/A Temp:N!6 O_.______........_.___,._._.__
3) anah siwat s ownbared and su numbs ofsheen o susedsd er tu up of aus fem and (4) each sheet is suunbed and dened by du owner a Owner's d

FOTG1 NIS-2 (b:ck)

9. Remarks : None.

Wphoss Man &,wsrs .mte Keppu 1o be acached) O CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Spnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: 8 IM Sunenisine ASME Codes Encineer Date: 4M9I Owner or Owmer's Designee, Title ' CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnanv (Factory Mutual Encineerine A ssociation) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period

      /#/AiI#44                to #f5/#S , and state that to the best of my knowledge and belief, the Owner has pe fohned examinations and take'n corr'ective measures described in this Oner's Repon in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Oner's Repon. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind a2ising from or connected with this aspection.

            /M h4&fc:>r                                Commissions             /M                           California InspectoPs Signatur(                                                National Board, State, Province, and Endorsements Date &, 3. ,WS .

I m

FORM NIS-2 OWNER'S un REPORT FOR REPAIRS OR REPLACEMENTS dw em n..< mr e s- oa ) 3hret I of,

                                                                                                                                                                 )
1. Owner [ Southem Califomia Edison Company Unit: 2 es 2244 Walnut Grove Avenue MO: 94081555000

(#) Rosemead,Califomia 91770 DCP: 2-6683.04SP  ! Rspec : 062 94 l

2. Plant: San Onc&e Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID : 40112A N-5 : S2 1204-34 I
3. WorkPerformedby: Southern Califomia Edison Company i T3pe Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section 111. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Nametr NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes*No - Mechanical Snubber Pacific Scientifm 9219 N/A S2S1185H001 1980 Replaced No PSA 1/2 - 21/2 101/4* Rigid Strut Lisega S2-SI-185-H-001 N/A RS0 0030-95 N/A Replacement No 3922RR1

7. Description of Work:

(~N The mechanical snubber was replaced with a rigid stmt in accordance with DCP 2-6683.04SP. The existing attachment () brackets were reused. A VT 3 examination of the support assembly was performed after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1204-014-4A (PSG-7)

8. Tests Conducted :Ha Pres: N/ MTemp:Na 1

f N.] - -

                     .-.__.,,._dm_s....,_.-,,,..-_.

3)msh shes a sunbered and tw sambe ofshwu a sessded a tw top of em % and (4) each sheet s semeled and ested by an Owner e O=sen dengne, arul Ow & , 1 I

FORM NIS-2 (back)

      - 9. Remarks : None.

m,,a u.auua uu m. w s. .n.a a> CERTIFICATE OF COMPLIANCE 0 , We cenify that the statements made in the repon are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: / // Owner or Owner's Desicnee, Title Supervisine ASME Codes Encineer Date: (I /95 CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comoanv (Factorv Mutual Enrineerine A ssociation) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 4#.//4/96 to 4//-3V96 , and state that to the best of my knowledge and belief, the Owner has perforfned e(aminations and taken corfective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manneifor any personal injury or property damage or a loss of any kind arising from or connected with this mspection.

                 /          hM@yr                           Commissions /84#2.                                Califomia Inspector's Signature /                                          National Board, State Prosince, and Endorsements Oe           4
                                                                                                                                         . l MO: 94061$$3000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regwed by 9e Provisions of te ASME Code $sceienXI Sheet I ef t

1. Oner: Southern Califomia Edison Company Unit : 2
  '(7-                    2244 Walnut Grove Avenue                                                                     MO: 94081654000 3          .            Rosemead, California 91770 DCP: 2-6683.04SP Rspec : 067-94
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID : 40112A '

N-5 : S2-1204-34

3. Work Performed by: Southern California Edison company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification ofSystem: SafetyInjection and Shutdon Cooling Expiration Date: N/A S. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identifica* ion of Componats Repaired or Replaced and Replacement Components:
                                                                                                                                            ' Repaired,      ASME Namfor                   NameOf               Manufacturer           National               Other                Year    Reptaced or      Code Component                 Manufacturer             Serial No.          Board No.           Identification           Built   Replacement     Stamped l

Yes%

  • Pipe Suppen --- --

S2S104SH002 -- .-- -- l 2* Pipe Guide Grinnell Ht. Code B-086 N/A RSO 1414-94, N/A Replacement No -i SA-36. Pt. CL144N  ;

7. Description of Work:
    %      Pipe support S25104SH002 was modified in accordance with DCP 2-6683.04SP by adding a 2* diameter pipe guide. All                                               i welding and NDE were performed using weld record WR2-94-323, followed by a VT-3 examination of the completed .                                                I support. 

Reference:

Stress calculationM-1204-014-4A (PSG-7) '

                                                                                                                                                                        .j i

l

                                                                                                                                                                         ]

1 I

8. Tests Conducted :N!% Pres:N!% Temp:N%

O _ . .. _ _ _ _ ._. _ _ . ,, ._ _ , ._e, . _ _

3) esta shes a swesend and en awaber ofshese a sweerd,d as the top of tes fem and (4) each ehea a sueeled and deasd by su owner er Owners deskues and du A

FORM NIS-2 (b:ck)

9. Remarks: None.

w a u.u - a,u. m wu. m , CERTIFICATE OF COMPLIANCE 9 We certify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: [Id M Supervisine ASME Codes Eneineer Date: 4[/!95 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the tmdersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comnanv (Factorv Mutual Encineerine Association) of Norwood. Massachusetts have inspected the components described in this owner's Report during the period

      /4 //4 /42 42-           to //43/W                    , and state that to the best ofrny knowledge and belief, the Owner has perforined ekaminations and take6 corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, sgssed or implied, concermng the examinations and corrective measures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection.

                !            A 44Jat Inspector's Signature /              '

Commissions /8 U California National Board, State, Province, and Endorsements Date khjY0 /WW y < m

FORM NIS-2 OWNER'S un REPORT FOR REPAIRS OR REPLACEMENTS  ; dere. % .r w.surcod.s.aorm . sh.so ori  !

1. Owner: Southern California Edison Company Unit : 2 3

. /~$ 2244 Walnut Grove Avenue - MO: 94081661000 i Rosemead, California 91770 DCP: ~ 2-6683.04SP . Rspec: 068 94 '

2. Plant: San Onofre Nuclear Generating Station '

San Clemente, California 92674-0128 P&ID: 40112A - N 5: S2-1204 34

3. . Work Perfonned by: ' Southem California Edison Company Type Code Symbol Stamp: N/A Authodzation No: N/A '
4. Identification of System: Safety Injection and Shutdouti Cooling Expiration Date: N/A  !

i

  • 5. (a) Applicable Construction Code: ASME Section III. Class 2 NF_1974 Edition. S*74 Addenda. Code Case: None .

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda :i

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Namcor Name Of . Manufacturer ' National Component Odwr . Year Replaced or Code

   ,                                                 Manufacturer                Serial No. Board No.           Identification                   Built  Replacement Stamped       -

YesNo Pipe Support --- N/A S2S1049H011- N/A --- --  ! 2* Pipe Guide Grinnell Ht. Code B-086 N/A RSO 1414-94, N/A Replacement No t SA-36, Pt. CLl44N l

7. Description of Work: I Pipe support S2SIO49H011 was modified in accordance with DCP 2-6683.04SP by adding a 2" diameter pipe guide. All O

l

                  . welding and NDE were performed using weld record WR2 94-327s followed by a VT-3 examination of the completed support. 

Reference:

Stress calculation M-1204-014-4A (PSG-7) - i q

                                                                                                                                                                                        .1 J
                                                                                                                                                                                   .       J I

i

                                                                                                                                                                                          .I 1
8. Tests Conducted:N_% Pres:NM Temp:H%

k ' NOTE " . . _ sheen m tu funn ofhat .: A er L- _,.sney be used proin6ed (1)saat b 8 ifJ h a il A.Q)afennamen si homa 1 Spagh 6 en the repon a mduded an each she 3)ansh shea b misnhered and en nur as orshese in resordsd si su top or sus $sent and (d) each shoes is summind and dated by b owner er Ommers emmysse end d l' i

FORM NIS-2 (b:ck)

9. Remarks: None.

w- unm=.r. m.,on, o .m O CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code S)Tnbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: M/ T d Supervisine ASME Codes Encineer Date: /'~ 95 Owner or Ow"mer's Desience, Title CERTIFICATE OF INSPECTION , I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Comoanv (Factorv Mutual Encineerine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period

           /f//9 /94-          to      3//5/c75              . and state that to the best of my knowledge and belief, the Owner has perfonned examinations and taken corrective measures described in this Owmcr's Report in accordance with the requirements of te ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any watranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any marmer for any personal injury or propeny damage or a loss of any kind arising from or connected with this a_ 03 on Commissions California 1574 Inspector's Signature National Board, State, Prosince, and Endorsements Date _ l 4.1995 ss eo; uwaem

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requred by the Pmmons of the A$ME Coes "U shaii ri

1. ' Owner: Southern Califomia Edison Company Unit: 2
 ' [3                     . 2244 Walnut Grove Avenue                                                                  MO: 94081662000
  'v/                      Rosemead, California 91770 DCP: 2-6683.04SP Rspec : 069-94
2. Plant: San Onofre Nuclear Generating Station
                        ' San Clemente, California 92674-0128                                                         P&ID : 40112A N-5 : ' S2-1204-34 3 WorkPerformedby:                Southern California Edison Company Type Code Spnbol Stamp: N/A Authorization No:                  N/A
       - 4. Identification of System: Safety Injection and Shutdown Cooling                                         Expiration Date:                   N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 AAAmda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared. ASME Name of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Idenufication Built Replacement Stamped YesNo Traverse Pipe Stop Bechtel N/A N/A S2SIl85H002 N/A Permanently No Deleted

7. Description of Work:

The traverse pipe stop and mounting plate were no longer required per the latest pipe stress analysis M-1204-014-4A (PSG 7) and were permanently removed in accordance with DCP 2-6683.04SP. v 1 I

8. Tests Conducted :N!% Pres:NM Temp:N!%

NOTE

  • _ ! sheet e em Sen otheek shatchu, e drawsgs nun be emed prwded (I)see is 8 P2 st a Il m,o) edornuten a hems t 8voegh 6 on tus separt a sw:tuded on each sheet, 3)each absen a numbend and Du nasabe of shoem a reemded at the top of the % and (4) each shoes a suested and dmed by the owner er Owners desense ed the AIA.

FORM NIS-2 (bick)

9. Remark,s : None.

we e w.,<,- - ,- CERTIFICATE OF COMPLIANCE O We certify that the statements made in the report are correct and this deletion confonns to the rules of the ASME Code, Section XI. repair or replacement T)pe Code S3 mbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: [//- Sunenirine ASME Codes Eneineer Date: (;d[if Owner or Owner's Desicnee, Title CERTIFICATE OFINSPECTION - I, the undersigned hoiding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rk,vricht Mutual Insurance Companv (Factory Mutual Engineerine Association) of Nonvood. Massachusett: have inspected the components described in this Owner's Repon dur:cg the period

          /2 //9 /94           to      J//4/96              . and state that to the best of my knowledge end N!ief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes ar y warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspecti (- Yut /33 'n Commissions Inspector's Signature California 674 National Board, State Province, and Endorsements Date Lb 1995 O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS us.e.aises %, .fu mscues a sw.o .n

1. Owner: Southern California Edison Company Unit: 2 2244 Walnut Grove Avenue MO:

(n*) Rosemead,Califomia 91770 940816S7000 DCP: 2-6683.04SP

2. Plant: San Onofre Nuclear Generating Station Rspec: 061 94 San Clemente, Califomia 92674-012S P&ID: 40112A N-5: S2-1204-34
3. WorkPerformedby: Southern California Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Safety 1njection and Shutdown Cooling Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section m. Class 2-NF.1974 Edition S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, A$kfE Nametf NameOf hianufacturer National Other Year Replaced or Code Component Efanufacturer Serial No. Board No. Identification Buut Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 36763 N/A S2S1014H012 1986 Permanently No PSA 1/4 Deleted Mechanical Snubber Pacific Scientific 20356 N/A S2S1014H018 1986 Permanently No PSA 1/2 Deleted Mechanic,.1 Snubber Pacific Scientific 460 N/A S2S1014H021 N/A Pennanently No PSA 1-4 Deleted

7. Description of Work:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M-1204-014-AA (PSG-8) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left in-place. The removed snubbers were placed into the snubber rebuild program.

8. Tests Conducted :Fl% Pres:H% Temp:NB k = . 2.s . mm . = _ , w ,. d m . .. . i x m .f ~ i . . we e. a.-
3) each sheet a owntwed and ou number ofsbess a pesardad ei en top of e. 5.r.( end (4) each sheet a swimled and esied by ou Owner er Owners demsner and Om AIA

FORM NIS-2 (b:ck)

9. Remarks : None.
                                                                     +ma-u      uuw,m em a.n.a,,

O

                          ,                                           CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this deletion                   confonnstothe rules of the ASME Code, Section XL                                                repair or replacement Type Code Symbol Stamp: N/A

} Certificate of Authorization No: N/A Expiration Date: N/A Signed: # b Sutiervisine ASME Codes Encineer Date: 4 /[95 Owner or Owner's Desicnee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insuranee Companv (Factorv Mutual Engineerine Association) of Norwood Massachusetts have inspected the components described in this Owner's Report during the period

                   /2/5/94                                to  J//5/95        , and state that to the best of rny knowledge and belief, the Owner has pe formed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of te ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owner's Report Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or cormected with this tnspectifn. et00. L L1. Commissions Califomia 1674 Inspector's Signature National Board, State, Prosince, and Endorsements Date b)b!$$ [ I 7

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regined by the Prewoons of tw ASMf, Code seenonXI Sheet i ofI s 1. Owner: Southern Califomia Edison Company Unit: 2 ( j 2244 Walnut Grove Avenue DCP: 2-6683.04SP V Rosemead, California 91770 MO: 94081688000 Rspec: 070 94

2. Plant: San Onofre Nuclear Generating Station
                          ' San Clemente, California 92674-0128                                                                              P&ID: 40112A N-5:         S2-1204-34
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A
4. IdentificationofSystem: Safety Injection and Shutdomi Coolm.g Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: .

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Buih Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 4194 N/A S2SIO14H019 1978 Replaced Yes PSA 1-4 241/4" Rigid Stmt Lisega S2-SI-014-H-019 N/A RSO 0030-95 N/A Replacement No 3942RR1 Rear Brackets w/ Load Lisega 3542RR1 N/A RSO 0030-95 N/A Replacement No Pins (2) [mV} 7. Description of Work: The mechanical snubber was replaced with a rigid stmt in accordance with DCP 2-6683.04SP and weld record WR2-94-328 The attachment brackets were also replaced. A VT-3 examination of the support assembly was performed after installatior. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1204-014-AA (PSG-8) l 1 i 1 l l l l

8. Tests Conducted: M/A Pres: N/A Temp: N/A l

Id0rE Supplemental stwets e the farm of hsm, aksiche, er drewegs may be used provuled (1) saan s 81/2 st a 11 m, C) m hems I through 6 en the report a ecluded on each sheet.

3) each sheet s numbered and em nwnher of sheets a reeaveed at the top of een form. and (4) each shool a svealed and deed by the Owner or Owners designes and du Al>L 1

FORM NIS-2 (b:ck)

9. Remarks : None.

LAPPuseoss Manuwscrs kam Aeperm W H erwheaj CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are concet a.nd this renlacement confonns to the rules of the ASME Code, Section XL repair or replacement T)pe Code Spubol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Signed: N/ // ~I/~ Sunenirine ASME CodesEncineer Date: 9 Owner or Oute/s Desicnee, Title ' CERTIFICATE OFINSPECTION

                                 '                                                                                            ~

I, the undersignpd holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwrfcht MutualInsurance Comosnv (Factorv Mutual Encineerine Association) of Norwood. Mass achusetts have inspected the components described in this Owner's Report during the period

               /2 / 7N4              to    3/% /96                 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures dese:ibed in this Oumer's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owmer's Repon. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or pr openy damage or a loss of any kind arising from or connected with this
       $5Pectip-caN Inspector's Signature
                                   .          cYi           Commissions                                          California 1574 National Board, State, Prosince, and Endorsements h

Date Q E 4,I903 V' m;wo.ma= h

l j FORM NIS-2 OWNER'S u n, REPORT FOR REPAIRS OR REPLACEMENTS d er e., % w rom AsW cWe SumM

                    '                                                                                 ss o.ri
       ). Outer: Southem Califemia Edison Company                                                     Unit : 2
-m                     2244 Walnut Grove Avenue                                                       MO: 94081689000

(") Rosemend,Califomia 91770 DCP: 2-6683.04SP Rspec : 07194

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID : 40112C N-5: S2 1204 11
3. Work Perfonned by: Southem Califomia Edison Company Type Code Syrnbol stamp: N/A Authorization No: N/A
4. Identification of System: Safety Injection and Shutdown Cooling Expiration Date: N/A f

S. (a) Applicable Constmetion Code: ASME Section III Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: . I989 Edition. No AddgL3 d

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Namesf Name Of Manufacturer National OLher Year Replaced or Code Component Manufacturer Seria1 No. Board No. Identification Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 4793 N/A S2S1021H002A 1979 Replaced Yes PSA l/2 Mechanical Snubber Pacific Scientific 4764 N/A S2S1021H002B 1979 Replaced Yes PSA 1/2 9" Rigid Struts (2) Lisega S2 SI-021-H-002 N/A RSO 0030-95 N/A Replacement No 3942RR1 (3 Rear Brackets (4) Lisega 3542RR1 N/A RSO OO30-95 N/A Replacement No V Load Pins (4) Lisega HL 257 N/A RSO 0030-95 N/A Replacement No

7. Description of Work:

The mechanical snubbers were replaced with rigid stmts in accordance with DCP 2-6683.04SP and weld record WR2 94-329. The attachment brackets were also replaced. VT 3 examinations of the support assemblies were performed after installation. The removed snubbers were placed into the snubber rebuild program.

Reference:

Stress Calculation M 1204-014-AA (PSG-8)

8. Tests Conducted :NE Pres:N!% Temp:He V ,,m .
                      .m.ew-.r _ . w                       d,-n..               ..ixmm,                 .e.d.em- ~.                  ~ descrwe and en AtA.

3)wh shee a menbe.d and om m ber ershe.m a e. ended a sw t, erem tem and (d) and sina a km.i.d and dead by en owner = owners

FORM NIS-2 (b:ck)

9. Remarks : None.

w u m .m ,on, .u.aw CERTIFICATE OF COMPLIANCE e We certify that the statements made in the repon are correct and this rentacement conformstothe rules of the ASME Code, Section XI. repairor replacement Type Code Symbol Stamp: N/A' Certificate of Authorization No: N/A Expiration Date: N/A signed: # e, /M Sunervisine ASME Codes Encineer Date: 4 95 Owner or Own'er's Designee, Title ' CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnanv (Factory Mutual Enrineerine Association) of Norwood. Massschusetts have inspected the components described in this Owmer's Report during the period

                   /2//4 /94             to     8//4/96                . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall t>e liable in any manner'for any personal injury or property damage or a loss of any kind arising from or connected with this inspectirrn. ( Oct L hA2 Commissions Califomia 1574 Inspector's Signature National Board, State, Prosince, and Endorsements

                                    ,   1995 Datev %.

h40 : 940818850 0

   ~

5 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS  ; As Reesd h h hevissens of h ASME Coh SatwM i

                                                                                      .                                                                  su s ers
1. Owner: Southern Califomia Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 94082002000 p)g.

t.

Rosemead, Califomia - 91770 DCP: 2-6683.04SP Rspec : 062-94
2. ' Plant: San Onofre Nuclear Generating Station P&ID : 40112A San Clemente, Califomia 92674-0128 N-5 : S2-1204 34
3. Work Performed by: Southem California Edison Company T3pe Code Spnbol Stamp: N/A Authorization No: N/A
4. IdentiScation of System: SafetyInjection and Shutdown Cooling Expiration Date: N/A l  ?
5. (a) Applicable Construction Code: ASME Section III. Class 2-h?. t 074 Edition. S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 589 Edition.No Addenda .
6. IdentiEcation of Components Repaired or Replaced and Replacement Components:  :

Repaired, ASME Name.of Nameof Manufacturer National 06er Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 3809 N/A S2SIO83H0AE 1977 Replaced Yes PSA 1/4 12" Rigid Strut Lisega S2-SI-083 H-0AE N/A RSO 0030-95 N/A Replacement No 3922RR1

7. DescriptionofWork:

( The mechanical snubber was replaced with a rigid strut in accordance with DCP 2 6683.04SP. The existing attachment (. brackets were reused. A VT-3 examination of the support assembly was perfonned after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Analysis PSG-#216 '

                                                                                                                                                                                                                   \

1

8. Tests Conducted:H/A Pres:M Temp:H/A

_ _ h .,,_ _ . ._d _.d ....., _ ._ _ , d . - _ ._ _

3) ensk sheet a sarnbead and the misaber of shesis is resweed a h top of des fars and (c) each sheet is botnied and enied by the oener er owners desqsner and to AIA.

O

FORM NIS-2 (back)

    . 9. Remarks : None.

w u m a u, w w . m \ l CERTIFICATE Oy COMPLIANCE ' We cenify that the statements made in the repon are correct and this renlac; ment conforms tothe rules of the ASME Code, Section XI. repair or replacement Type Code Syrnbol Stamp: N/A Certdicate of ^.cthorization No: N/A Expiration Date: N/A Signed. [/8 AIZ --- Sunenisine ASME Codes Enrinen Date: fM/9 T Owner or Owner's Desicnee Title

                ~

CERTIFICA7E OFINSPECTION I, the undersigned homing a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, and employed by A rkwricht Mutualinsurance companv (Factorv Mutual Enrineerine A ssociationi of Norwood. Massachusetts have inspected the components descibed in this Owner's Repon during the petivo

               #4/4WI to W W /4P C . and state that to the best of my knowledge and belief, the Owner has g/m, edVxafninations and takin corfective measures described in this Owner's perfo                                                                                                                       Repon in a te ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any wananty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this mspection. AMsb ' Commissions /84 5 California Inspecthr' signatur( National' Board State. Prmince, and Endorsements Date *AcT ' N C kJ: D4062002000

4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regured by ow Prewmans of om ASME code $scasc3 sh iiori ex 1. Ovmer: Southem California Edison Company Unit: 2 I

    )                      2244 Walnut Grove Avenue                                                                                     MO:         94082003000                           !

L/ Rosemead, California 91770 DCP: 2-6683.04SP l

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40114B N.5: S2-1206-1
3. WorkPerformedby: Southern California Edison Company Type Code Symbol Stamp: N/A Authorization No: N/A '
4. Identification of System: Containment Spray Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section M. Class 2-NF.1974 Edition. S*74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name'of Name Of Manufacturer National Cr.her Year Replaced or Code Componera Manufacturer Serial No. Board No. Iderairication Built Replacernent Stamped Yes/No Mechanical Snubber Pacific Scientific 25762 N/A S2CS003H011 1986 Permanently No PSA 1-4 Deleted Mechanical Snubber Pacific Scientific 3580 N/A S2CS003H053A 1978 Permanently Yes PSA 1/2 Deleted Mechanical Snubber Pacific Scientific 2596 N/A S2CS003H053B 1978 Perranently Yes p PSA 1/2 Deleted Mechanical Snubber Pacific Scientific 2588 N/A S2CS003H063A 1978 Permanently Yes i"/ PSA 1/2 , Deleted Mechanical Snubber Pacific Scientt5c 20431 N/A S2CS003H063B 1987 Permanently No PSA 1/2 Deleted

7. Description of Work:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M-1206-003-AA (PSG-53) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left in-place. The removed snubbers were placed into the snubber rebuild program. I l i 1 i

                                                                                                                                                                                          )

i i l l l I

8. Tests Conducted :NB Pres:M% Temp:NB l

3 8 m) NorlL ? _, , ' sheen m Om farm ofbsik s&stlus, er drewmp any be used prow (1) mas s $ 81 m a Il rL Q) adormataa e lens 1 Brotch 6 on the repen a mduded on sech sheet, 3)sech sheet a . and Ow ownbar of shesen a ncorded as Ow top of Om fann, and (4) each sheet a sannse and deud by tw Owner or Owner's demsnee and Ou AR 1

r FORM N'IS-2 (b:ck)

9. Remarks : None.

i w uu- u.n ~ ~pa. a .m -> CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are concet and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: NN [/ Stmenisine ASME Codes Encmeer Date: 9M95' Owner or Owfer's Desicnee. Title CERTIFICATE OFINSFECTION I, the undersigned hoiding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province Bf California. and employed by A rkwricht MutualInsurance Comnanv (FactorOfutual Enrineerine Assoelatlon) of Norm ood Massachttsetts have inspected the components described in this Owter': Repon during the period A:2M~M(4 to M ~ F 9 C , and state that to the best ofmy knowledge and tdef, the Owner has perforfned fcxaminations and take'n corfective measures described in this Outer's Report in accordance with the requirements of .

       'he ASME Code, Section XI.                                                                                                         '

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and conective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuy or property damage or a loss of any kind arising from or connected with this aspection. [ ~ M2> r Commissions 8 s f 2. California InWector's Signature' National Board, State, Province, and Endorsements Date 7 0AZ/ 1,9' $T - mo: uoerxxxn

l

                                   ' FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As llegasi h $t hew cf he t.5ME code SedmXI
                                                                             .                                                           shnis n
1. Owner: ~ Southem California Edison Company - Unit : 2 2244 Walnut Grove Avenue MO: 94082005001 95030517000 l 5 j( 7 Rosemead, California 91770 DCP: 2-6683.04SP ,

Rspec : 062-94 l

2. Plant: San Onofre Nuclear Generating Station P&ID : 40114B  !
                               , San Clemente, Califorma 92674-0128 N-5 : S2-1206-1                                        :

1

3. ; Work Performed by: Southem Califomia Edison Company Type Code Symbol Stamp: N/A .f Authorization No: .N/A-  !
4. Identifice. tion of System: Containment Spray Expiration Date: N/A l I

i

5. (a) Applicable Construction Code: ASME Section III. Class 2 NF.1974 Edition. S*74 Addenda. Code Case None {

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Editior. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components Repaired, -

Namesf Name of Manufacturer National - Oiher Year Replaced or ASMEl Code l i Component Manufacturer Senal No. Board No. Identification Built Replacement Stampt i Yes'No l t 10" Rigid Strut Lisesa S2-CS-003 H-061 N/A RSO 0030-95 N/A Replacement No i 3922RRIS  ! Load Pins (2) Pacific Scientific Ht. Code N2959 N/A RSO 2657 90 N/A Replacement No l SA-564 Gr 630 -  : i

          ' 7. Description of Work:
       /O        A rigid strut was installed in accordance with DCP 2-6683.04SP. Replacement lead pins were required to support the V

installation. A VT 3 examination of the support assembly was performed afterir.stallation.

Reference:

Stress Calculation M 1206-003-AA(PSG-53) I

                                                                                                                                                                                           -    i l

1 I l

                                           ,                                                                                                                                                    )
8. Tests Conducted :H M Pres:H% Temp:H/a <

O - -..-.-,-....e..,_..h....--

3) each shoe o anhared and su maste.fshwa b resseesd et the esp.f 9m farms and (4)such sham h suested and esand by tu Ommer a Ommary duense and en AM.

i 1

E '~ FORM NIS-2 (back)

9. Remarks : None.
                                                         % u==.r. woon. w .r a.

O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confonnstothe mies of the ASME Code, Section XI. repair or replacement Type Code Syrnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: 8 Supervisine ASME Codes Encineer Date: Y 8 Owner or Oumer's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Company (Factory Mutual Enrineerine Association) of Norwood. Mass achusetts have inspected the components described in this Owner's Report during the period 2 // S/ 9.5 to J//t /95 , and state that to the best of my knowledge and belief, the Owmer has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of We ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owmer's Report. Funhermore, neither the Irgector nor his employer shall be liabley any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this mspectw9 C btOOJt . ') Commissions California I574 Inspector's Signature National Board, State, Province, and Endorsements Date k fS $$ wo; usan smi I

k FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS us awu % .ru erca.s. amu Sheet i of I

1. Owner: Southem Califomia Edison Company Unit: 2 s 2244 Walnut Grove Avenue DCP: 2 6683.04SP Rosemead, California 91770
          )                                                                                                                            MO:         94082007000 Rspec: 062-94
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40114B N-5: S2 1206 1
3. Work Performed by: Southem Califomia Edison Company Type Code S 3 mbolStamp: N/A
4. Identification of System: Containment Spray Authorization No: N/A Expiration Date: N/A L
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF 197f. Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of NameOf Manufacturer National Other Year Reptaced or Code Component Manufacturer Serial No. Board No. Identification Built Reptacement Stamped Yes/No Mechanical Snubber Pacific Scientific 7152 N/A S2CS003H065B 1979 Replaced Yes PSA 3 5 Mechanical Snubber Pacific Scienttfic 7149 N/A S2CS003H065T 1979 Replaced Yes PSA 3 5 19" Rigid Stnits (2) Lisega S2-CS-003-H-065 N/A RSO 0030-95, N/A Replacement No 3942RR1 CCase N249 ('s (") 7. Description of Work: The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. Existing attachment brackets were reused. VT-3 examinations of the support assemblies were performed aner installation. The removed snubbers were placed into the snubber rebuild program.

Reference:

Stress Calculation M-1206-003-AA (PSG-53)

8. Tests Conducted: NJB Pres: N_% Temp: NJ%

77 I won - . 2.h.meens=..rh,m,.h 6.. ,w.ap,w ac 3.m s an s u so,a) ed sm a ham I Swough 6 m 8m nyan b erkda e me she4 3)each shes e ownbared and se ownbe ernharm a rusarded at se esy of aus larm, and (4) each abat s esenled and daned by tu owns er ourne's degnse and du &

FORM NIS-2 (b:ck)

9. Remarks : None.
                                                      #,s   w u.nw-u..r. o    yon. i. i,. . u ,

O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonns to the rules of the ASME Code, Section XI. repair or replacement Type Code Syrnbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed; d b Owner or Owner's Designee, Title Supervisine ASME Codes Encineer Date: N96 CERTIFICATE OF INSPECTION . I, the undersigned holding a valid commission issued by the National Board '7 oiler and Pressure Vessel Inspectors and the State or Province of California and employed by A rkwricht MutualInsurance Company (Factorv Mutual Enrineerior Association) o Norwood. Mausschusetts have inspected the components described in this Owner's Report during the period A:?#/ # to #/6/Q6~ . and state that to the best ofmy knowledge and belief, the Owner has perfo/med 6xami6ations and tafen ecfrrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Oumer's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this mspection. [ Avd/d.or ' Commissions /I U California Irspector's Signatur/ ' National Board, State, Prosince, and Endorsements Date/18s B/Nf l

          /'                                                                                                                            .

l l l l l uo; mamme

-. a . --

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ~ . As n.ep dby e n m..re. Aswc.d.sawmxi Shem l ofi E 1. Owner: Southem California Edison Company Unit: 2 [- ]

   -()                       2244 Walnut Grove Avenue Rosemead, California 91770 MO:        94082017000 DCP: 2-6683.04SP Rspec 061-94
2. Plant: San Onofre Nuclear Generating Station l San Clemente, California 92674-0128 P&ID: 40114B N-5: S2-1206-1
3. WorkPerformedby: Southern Califomia Edison Company T)pe Code Symbol Stamp: N/A Authorization No: N/A
4. Identification of System: Containment Spray Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 AddmA=_ Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: ,
                           ,                                                                                                                                    Repaired,       ASME Name of                      Nameof                     Manufacturer                National                Other               Year       Replaced or      Code Component                   Manufacturer                   Serial No.               Board No.            Idersification          Built      Replacement     Stamped YesNo Mechanical Snubber              Pacific Scientific          3090                                N/A         S2CS003H041                   1978     Pennanently         Yes PSA :-4                                                                                                                                               Deleted 7, DescriptionofWork:

The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M lh06@3-4A (PSG-55) and were permanently removed in accordance with DCP 2 6683.04SP. The rear brackets wwe left in-place. The removed snubbers were placed into the snubber rebuild program.

8. TestsConducted:NS Pres:F/A Temp:N!%

O V NO3 Sh aheet h Om fann afhm.sketshe, se drueugs may be imed Inc uled (1) mar s 9 th a Il m o) mfarmsten a luns i Srough 5 an tem nyan a moluded an each shock M such shes a manhoud and ou asuber of sheseus sesorded m en top of Gus inrnt and (d)such sheet a siamhd and deemd by tw Owns as owners eaugnse and the AR 4

                                                             - FORM NIS-2 (back)
9. Remarks: None.

w3. .r.= , -,,on, .n.a , CERTIFICATE OF COMPLIANCE O We cenify that the statements made in the repon are correct and this deletion conformstothe rules of the ASME Code, Section XI. repair or replacement T3 pe Code S 3 mbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: [/I .I M Surenisine ASME Codes Eneineer Date: fM.95 Owner or Duner's Desicnee. Title CERTIFICATE OFINSPECTION

  • I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors a or Province oTCalifornia and employed by Arkwricht MutualInsurance Comnanv (Factorv Mutual Enrineerine Association) Norwood. Massachusetts have inspected the components described in this Owner's Repon during the period
             /X6 44                  to 4// M 9 C . and state that to the best of my knowledge and belief, the Outer has perfofmeicxaminations and take6cordctive measures described in this Owner's Repon in accordance with the requirements of We ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a losoof any kind arising from or connected with this nspection. Inspector's Signatud h- ' Commissions MdJ2 Califomia National Board, State Province, and Endorsements Date N, f . d/WT .a 1 W: 940tG017000

                         ' FORM NIS-2 O"WNER'S REPORT FO.R REPAIRS OR REPLACEMENTS I
                                                             - 4 a. ar.d er e e m   ametsus e.d.s-.=u                                                                              '

ss.a i ef s i

1. Owner: - Southern California Edison Company . Unit: 2 A 2244 Walnut Grove Avenue MO: 94082019000

~Q Rosemead, California 91770 DCP: 2-6683.04SP . Rspec : 062 2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40114A N-5 : S2-1206-1

3. WorkPerformedby: Southem Califomia Edison Company Type Code Symbol Stamp: N/A-Authorization No: N/A .
4. Identification of System: Containment Spray Expiration Date: N/A ,

1

5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Nameef Repaired, .ASME NameOf Manufacturer National Odwr Year Replacedor Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No , Mechanical Snubber Pacific Scientific 3639 N/A S2CS003H043~ 1978 Replaced Yes PSA l-4 15 3/16" Rigid Strut Lisega S2 CS-003-H-043 N/A RSO 0030-95 N/A Replacement No 3932RR1S

7. Description of Work:

(S The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT 3 examination of the support assembly was perfonned after installation. The removed snubber -

  • was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1206-003-4A (PSG-55) I 1 i S. Tests Conducted :N!% Pres:He Temp:N% l WOTE ..

                     ._ ahere to sw form of has, abseshes,e drewwge may be und prended (1) sur b 8 trJ m a Il n. C) biformanen s tumm i eveugh 6 en the wpmi s wukded en och ehed.

3)ensk shed is numbered and 1he aseher of aheum a socarded ai sin esp of dem % and (d)ensk sheet a bienled and ested by the owner er Owner's dungnes and the AD

FORM NIS-2 (b ck)

9. Remarks : None.

m~ uaa. a, va u,.n u, u .una, O CERTIFICATE OF COMPLIANCE We certify that the statements made in the repen are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replaxment Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed; b Owner or'Owmer's Desicnee, Tit;e Sunervisine ASME Codes Encineer Date: /!95 CERTIFICATE OF INSPECTION ,

                                                                                                                                         )

I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Comoanv (Factorv Mutual Encineerine AssociationM Norwood. Mas sachusettshave inspected the components desenbed in this Owner's Repon during the period MAV944 to /X/8VM . and state that to the best of my knowledge and belief, the Owner has perfonfied 6xaminations and taken' corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Repon. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. feh ' Commissions Afd.Z Califomia Inspector's Signatuf'c National Board, State, Province, and Endorsements Datch < 9, NS l i 1

 . a--                                                                                                                                       .

I 1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A. no w w e. p==-.m afdw ASMs Code Se:anM i Sheet I ofi

1. Owner: Southem California Edison Company . Unit: 2
 . rO.                     2244 Walnut Grove Avenue MO: .94082020000

() Rosemead,Califomia 91770 DCP: 2-6683.04SP l Rspec: 062-94

2. Plant: San Onofre Nuclear Generating Station P&ID: 40114A i San Clemente, Califomia 92674-0128 N-5: S2-1206-1
3. WorkPerformedby: Southem CalifomiaEdison Company Type Code Symbol Stamp: N/A
4. Identification of System: Containment Spray Authorization No: N/A .

ExpirationDate: N/A

5. (a) Applicable Constniction Code: ASME Section III. Class 2 NF.1974 Editien. S'74 AAAmda Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda '

{

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaared, ASME , NameBf Kame Of Manufacturer National Other Year Replaced or Code r Component Manufacturer SerialNo. Board No. IM-" Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 2671 N/A S2CS003H044 1977 Replaced Yes  ; PSA 3  ; 19-3/4" Rigid Strut Lisega S2-CS-003-H-044 N/A RSO 0030-95, N/A Replacement No 3952RR1S CCase N249eN71

7. Description of Work:

FT Q  : The mechanical snubber was replaced with a rigid stnit in accordance with DCP 2-6683.04SP. The existing attachment  ; bedets were reused. A VT-3 examination of the support assembly was performed afterinstallation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M-1206-003-4A (PSG-55) i i l

8. Tests Conducted: N/A Pres: N/A Temp: Fl/A 1

. t NOTc Suppismanid sheet a Ow lona of hsm, skmchen, er droorgt enny be seed provided o) mas is B !!! n a Il n. c) '. m lisses 1 Ovough 4 en Oss report a ecluded on each shee'. 3)each shaus a awnbend and su nurnber of shave a recorded at tw top of the forrn, and (4) each chnet a ente' ad sad deced by se Owner er owner's demones and the ADL

l FORM NIS-2 (b:ck)

9. Remarks : None.

mewa,- pon. . .mm, CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rentacement conforms to the rules of the ASME Code, Section XI. . repair or replacement Type Code Syrnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed:  ! d Supervisine ASME Codes Encineer Date: 4/5[96 Outer or Outer's Desicnee, Title CERTIFICATE OF INSPECT]ON ,, I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orProvince of California. and employed by Arkwricht Mutual Insurance Company Factorv Mutual Enrioeerine A s sociation) ofNorwood. Mass schusetts have inspected the components described in this Owmer's Report during the period

       /4/4/Q'<4 to 4t/7/8T . and state that to the best of my knowledge and belief, the Owner has pe fornfed claminations and taliesconictive measures described in this Owner's Report in accordance with the requirements of
le ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Ouner's Report. Furthermore, neither the Inspector nor his employer shall

 ~be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this uupection.

A?//f2ds/n InspecioPs' Signature / Commissions /[ d California National Board, State, Province, and Endorsements Date b,l$4/.7., $T l 1 m i l l w

F t FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regasped by 04 Pre +1swns of the A5ME code SecacrA1 sh I ori

1. Ow11er:- Southern California Edison Conipany Unit: 2 o-2244 Walnut Grove Avenue DCP: 2-66S3.04SP  ;

Rosemead,Califomia 91770

        )-                                                                                                                                          MO:        94082021001 Rspec: 062-94
2. Plant: San Onc 5e Nuclear Generating Station P&ID: 40114B San Clemente, California 92674 0128 N-5: S2 1206-1
3. Work Performed by: Southern Califomia Edison Company T3pe Code Spnbol Stamp: N/A Authorization No: N/A
4. Identification of System: Containment Spray Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.NP.1974 Edition. S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Rep;acements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components: -

Repaired. ASME Namecf Name of Mar ufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YeCNo Mechanical Snubber Pacific Scientific 2632 N/A S2CS003H046A 1977 Replaced Yes PSA 3 Mechanical Snubber Pacific Scientific 2631 N/A S2CS003H046B 1977 Replaced Yes PSA 3 18 9/16* Rigid Struts Lisega S2-CS-003-H-046 N/A RSO OO30-95e N/A Replacement No (2) 3952RR1S CCase N249

  ,r                                                                                                                                                                                                       :
 - ( }/
7. Description of Work:

The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. Existing attachment brackets were reused. VT-3 examinations of the support assemblies were performed after installation. The removed snubbers were i placed into the snubber rebuild program.

Reference:

Stress Calculation M 1206-003-4A (PSG-55)  ; I l l l

8. Tests Conducted: N/A Pres: N!% Temp: NB f3 Pf07E: Supplenuntal shosts tri the fans ef tsis, aksuhos, er drawing siay be imed provided (1)ser s t IfJ bL e Il sh, Q) hiasmatan h hans l Oveesh 4 se tus repari s bcluded en each sheet 3)each sheet n - " and ou misaber ofsheets e sunorded at ou sep of ess fem and (d)each shoes a sunnand and ested by the Owns er Osmers desgner and De AW

FORM NIS-2 (b:ck)

9. Remarks : None.

m uma wm.w , O CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: [N/ /I Owner or Owner's Desicnee, Title Supervisine ASME Codes Encineer Date: 4MM CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Company (Factorv Mutual Encineerine Association) of Norwood Massachusetts have inspected the components described in this Owner's Report during the period 2/7/95 to J//5/'f5 . and state that to the best of my knowledge and belief, the Owner has perfonned examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of

he ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Repon. Funhennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

       .'tYW          l     kla     n              Commissions                                        Califomia N Id.spector's Signature                                          National Board, State Province, and Endorsements Date     b         0$

l 1

1,

                                    -. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEn1ENTS                                                                                                                ;
4. n..e.d w a mm eu Asus c.d. s.amx, .
                              ,                                 ..          .                                                              sw d.                                                          i
1. Owner: Southern Califomia Edison Company Unit: 2 l,%- 2244 Walnut Grove Avenue MO: 94082022000 )

. :( L Rosemead,Califomia 91770 DCP : 2-6683.04SP - V Rspec: 062 94

2. Plant: San Onofre Nuclear Generating Station P&ID : 40114B-San Clemente, California 92674 0128 N-5: S2-1206-1 l
3. Work Performed by: Southem Califomia Edison Company -

Type Code 53 mbol Stamp: N/A . Authorization No: N/A

4. Identif, cation of System: Containment Spray Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case None

~- (b) Applicable Edition of Section XI Utilized for Repairs orReplacements: 1989 Edition.No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                                                                                                       ~

Repaired, ASME Nameaf Name of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacemera Stamped Yasso . Mechanical Snubber Pacific Scientific 2161 N/A S2CS003H047 1977 Replaced Yes PSA 3 5 18 9/16' Rigid Strut Lisega S2-CS-003 H 047 N/A RSO 0030-95 N/A Replacement No 3952RR1S

7. Description of Work:

s- The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. "Re existing attachment j brackets were reused. A VT 3 examination of the suppen assembly was performed afterinstallat. ion. The removed snubber i was placed into the snubber rebuild program.

Reference:

Stress calculation M 1206-003-4A (PSG-55) 1 r e 4 I

8. Tests Conducted:H% Pres:Na Temp:H!/A i

O _ s_ _ _ _e. _ m_..,_.,____.._.h.. _. _

3) enra shee a misabwed and en aanho etshout s esswend at en tar of aus faren, and(4)each eben a svenhd and diend by die ones er Owner's damipuu and da AR.

i I

6 FORM NIS-2 (back)

9. Remarks: None.

vou u.n aa. w a.,,,. . -, w CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: , Sunervisine ASME codes Encineer Date: f[95 Owner or O'wner's Designee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid corrunission issued by the National Board ofBoiler and Pressure VesselInspectors and the State or Province of California. and employed by A rkwricht MutualInsurance Company (Factorv Mutual Enrineerine Association) of Norwood. Massschusetts pave inspected the components described in this Owner's Repon during the period

           / 4 /4 6 7 # (2. to 4#5F9S . and state that to the best of my knowledge and belief, the Owner has perfor6ed efaminations and taken'corre4tive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection. 8 #-shof

                        ~

Commissions /3:Id4 California Inspecior's Signature '# National Board, State, Prosince, and Endorsements Date bs S,/995 r - I l 1 l j i i l 1 M I l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS . A. n -ora.p .rm. Asw c.a. - EbensIofI

1. Owner. Southem Califemia Edison Company Unit: 2

],)/ L

    -                    2244 Walnut Grove Avenue Rosemead, California 91770 MO: 94082256000 DCP: 2-6683.04SP
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 P  : 0 12B g ,g
3. WorkPerformedby: Bechtel Constmetion Company' P.O. Box 450 Type Code SymbolStamp: N/A 7

San Clemente, CA 92674-0128 AuthanzationNo: N/A Expiration Date: N/A

4. Identi5 cation of System: Safety Injection and Shutdown Cooling .
5. (a) Applicable Construction Code: ASME SectionIIL Class 2-NF.1974 Edition. S'74 Addeds. Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addman
6. Identification of Components Repaired or Replaced and Replacement Components: .. . .-

Repaired. ASME Name of Nomeof Manufacturer National Other Year Replaced or Code Cornponent Manufacturer Serial No. Board No. tdentification Built Replacement Stamped YesNo , 2" NPS Sch. 80 Pipe Consolidated Heat 427512 N/A RSO 0071-95, N/A Replacement No Power Supply SA 106 Gr.B, CR 2000-94 (g 2" 90 deg Elbow Capitol Mfg. Ht CodeRI12N N/A RSO 3248-92, N/A Replacement No (j SA 105,

                                                                        .                  CR 88-007 14" Pipe Clamp          Lisega               S2 SI-038-H 116           N/A      RSO 0194 95,              N/A Replacement                             No Heat A272D                         SA515-55 Pipe Clamp Bolts (2)     Nova Machine         Ht Code 3M08093           N/A      RSO 1609 94,              N/A Replacement                             No Products                                                SA 193 Gr.E7, CR 2001-93 Pipe Clamp Nuts (5)      Vitro,Inc.           Heat 108                  N/A      RSO0572 95,               N/A Replacement                             No SA 194 Gr. 2H I/4" x 1* U-bolt        GrinnellSupply                                 N/A      RSO 1414 94,              N/A Replacement                             No SA 36 Hex Nuts (6)             GrinnellSupply                                 N/A      RSO 1414-94,              N/A Replacement                             No      I SA-563 Gr. A                                                                  l
7. Description of Work:  ;

A new pipe support assembly was installed in location S2S!038H116 in accordance with DCP 2-6683.04SP. Installation was performed using weld record WR2-94 356. A VT-3 examination was performed on the support assembly with satisfactory results. Reference Stress Calculation M-1204-038-5A (PSG 74)  ! l

8. Tests Conducted: N!A . Pres: E% Temp: N/%
       -       ;.a.            ..:=:===:==:..o===--

FORM NIS-2 (b:ck)

9. Remarks : Applicable code reconciliations have been identified in Block 6.

w e.=m - .a.a.,-.. e CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacer 2ent conformstothe rules of the ASME Code, SectionXI. repair or replacement T3 pe Code Symbol Stamp: N/A Cenificate ofAuthonzationNo: N/A Expiration Date: N/A Signed: Sunervisine ASME Codes Encineer Date: X // SS Owner o"r Owner's Designee, Title / l CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State j or Prevince of California. and employed by A rkwriebt MutualInsurance Comoanv (Factory Mutual Enrineerine A ssoef ation) of Norwood. Massschusetts have inspected the components described in this Owner's Report during the period -- 1//A/GS to M4f M . and state that to the best of my knowledge and belief,'the Owner has perforrned ex'aminations and takc6 corrective measures described in this Owner's Report in accordance with the requirements of { the ASME Code, Section XI. l l By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his emplo3w shall  ! be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this l

       .nspection.                                                                                                                           '

Arddwt ' Commissions _fNSM. California inspector's fiij; nature / National Board, State, Prosince, and Endorsements l Date bEA-g

                            .h, /Q QT ko: Sce.?Acao O
                          . FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As llequerd by the Prevuiens of the ASME Code $semenXI
                                                              .                                                           Sheet 1 ofi
1. Chmer: Southem Califomia Edison Company Unit: 2

,e 2244 Walnut Grove Avenue DCP: 2-6683.04SP (m) w ./ Rosemead,Califomia 91770 MO: 94082257000 Rspec 062-94

2. Plant: San Onone Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40124B N-5: S2-1208-5
3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A
4. Identification of System: Chemical and Volume Control Authorization No: N/A Eg' ntionDate- N/A S. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

I Repaired. ASME Name.,pf Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Buih Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 5929 N/A S2VC008H039A 1978 Replaced Yes PSA 1/4 Mechanical Snubber Pacific Scientdie 5923 N/A S2VC008H039B 1978 Replaced Yes PSA 1/4 121/16" Rigid Stmts Lisega S2 VC-008-H-039, N/A RSO OO30-95 N/A Replacement No (2) 3922RR1S rm ('") 7. Description of Work: The mechanical snubbers were replaced with rigid stmts in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. VT 3 examinations of the support assemblies were perfonned after installation. The removed snubbers were placed into the snubber rebuild program.

Reference:

Stress Calculation M-1208-008-AA (PSG-110)

8. Tests Conducted: N!/A Pres: N!A Temp: N!A b NOrt Supplemental ahe a e the fann ef tsas skeuM or esewys ney be ined peended (1)aan is 8 I"J m a la m, c)oderummemir; hems 1 Ovough 6 se Ous repun a edaded on e 3)eeshihse a m abned and1he murnbar of she u a venerdad at the tar of Ous form.and (4 each sheet a sotaled and daud by tu owns e Owner's degnee and the AIA

FORM NIS-2 (b:ck)

9. Remarks: None.

w wwa,me n ,m O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this uplacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: M4 IM Sunetvisine ASME Codes Encineer Date: Y' 85 Ouner or Owner's Desicnee. Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Company (Factorv Mutual Encineerinz Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period

              /2//1/W              to     N 2 5/'/S              . and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Report in accordance with the requirements of
      'Jie ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liablyin any manner for anyyersonal injury or property damage or a loss of any kind arising from or connected with this inspection. - (' s c a c. h1 on Commissions Cahfornia I674 Inspector's Signature National Board, State, Prosince, and Endorsements Date Mo: 9401o257000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requee,by 6. Previ.iors of 0. ASMI C.dr 5.etied1 Sh.et I ofI i

1. Owner: Southem Califomia Edison Company Unit: 2 l s 2244 Walnut Grove Avenue DCP: 2-6683.04SP Rosemead, Califamia 91770 '

( ) MO: 94082258000 Rspec: 062-94

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40123B N-5: S2-1208-5
3. WorkPerfonnedby: Southem California Edison Company Type Code Symbol Stamp: N/A
4. Identification ofSystem: Chemical and Volume Control Authorization No: N/A i Expiration Date: N/A
5. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition. S*74 Addenda. Code Case: None -

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Namcor Name Of Manufacturer National Ohr Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped YesWo Mechanical Snubber Pacific Scientific 11123 N/A S2VC104H019A 1980 Replaced No PSA14 Mechanical Snubber Pacific Scientific 9122 N/A S2VC104H019B 1979 Replaced No PSA 1-4 14 7/16' Rigid Stmts Lisega S2-VC-104 H-019 N/A RSO 0030-95, N/A Replacement No l (2) 3932RRI CCase N249, N71 (Q

'~'

j 7. Description of Work: The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. The existing attachment  ; brackets were reused. VT 3 examinations of the support assemblies were performed after installation. The removed snubbers j were placed into the snubi rebuild program.

Reference:

Stress Calculation M-1208-008-AA (PSG-110) l l l 1 I i l i

8. Tests Conducted: N!% Pres: H% Temp: N/A O

V = .r __ , .,m,.

                       ... _m      ._ ,. .<.,   . . _ ,. ,., ,,. _ m ,. ._n, . . i i              - .               i ~ .
                                                                                                                        .~           _. . . x 9

FORM NIS-2 (b:ck)

9. Remarks : None.

mmw.ae. uw w .wa> CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are conect and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: // II/- Supervisine ASME Codes Eneineer Date: 9 9f Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comnanv (Factorv Mutual Enrincerine Association) of Norwood. Mass schusetts have inspected the components described in this Owner's Report during the period

          /.2 //6 /14-            to     d/26M5                . and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI.

By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concenung the examinations and coni etive measures described in this Outer's Report. Furthermore, neither the Inspector nor his employer shall be liableAn any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspectIan Ort k'G- L-V1 Conunissions California 1574 Inspector's Signature National Board, State, Prosince, and Endorsements Date d h l _ a__ O

         --                                                                                                             ~

s > FORM NIS-2 OWNER'S ua.,ewwREPORT FOR s.d.ea n _.re 4suse.a REPAIRS OR REPLACEMENTS --

           -                                                                                                     Shne1.fi
  • 1. Oumen SouthemCalifomiaEdisonCompany Unit: 2 2244 Walnut Grove Avenue Rosemead, California 91770 MO: 94082323000,94071419000 DCP 2-6988.00 0 l 2 Plant: San Onofre Nuclear Generating Station '94 R1,007 94-6988 San Clemente, California 92674-0128 - 3 N-5: S2-1208 11
3. WorkPerformedby: BechtelConstmetion Company
j. P.O. Box 450 T)pe Code SpnbolStamp: N/A San Clemente, CA 92674 0128 r.

AuthorizationNo: N/A f ExpirationDate: N/A i

4. IdentiScation of System:' Chemical and Volume Control P
5. (a) Applicable Ccidstruction Code: ASME Section III. Class 2.19[1 Edition. S'73 ANAa (Kerotest & Cu
  • Vahesi 1974 Edition. S'74 Addenda finstallationi 1974 Edition. S'75 Addenda (Henry Vent Valvel Code Casec None (b) Applicable Edition of Section XI Utilized fce Repairs or Replacements: 1989 Edition. No Addenda. Code C
6. Identi5 cation of Components Repaired or Replaced and Replacement Components:

Nares of NameOf Repaired, ASME Marmfacame National O&er Year Compenant Manufacarer Replaced er Code . SerialNo. Board No. Idenuracation BuDt ' Replacement Stamped YesWo l'NPS PipeSpool Bechtel N/A N/A S21208MID98, 1978 Repaired No S2-VC-098-00A 1* Sch 40S Seamless Sandvik Heat 461879 N/A RSO 1567 90, N/A Replacement No

           \          Pipe V(^              l' 3000# 90 Deg. SW Alloy Stainless             Ht Code AIS              N/A SA-376 TP 304 RSO 2299-93,              N/A Replacement Elbow                          Products                                                                                           No SA 182 F316, CR 3012      ,

3' Sch 40S Pipe AlTech Specialty HeatAH8352 i N/A RSO 175194, N/A Replacement No

 '!                                                                                                     SA 376 TP304 3' 90 Deg. Elbow               Ladish Company    Ht CodeZ4TSJ             N/A     RSO 1388-94,              N/A Replacement       No SA-403 WP304 3' x l' Weldolet Sch            WFI,Inc.          Heat 775VNA              N/A     RSO 1396-94,              N/A Replacement       No 40S -

SA 182 F316 l'BW Globe Valve Kerotest owl 1-10 N/A S21208MR050 1976 Replaced Yes l' SW Gate Vah'e Henry Vogt 4 216848 N/A RSO 0471-94 1994 Replacement Yes 3' BW Gate Valve Control 653361 1 1 N/A RSO 1445-94, 1994 Replacement Yes Components S21208MU216

7. DescriptianofWork: '

In accordance with DCP 2-6988.00SN, gate vahe S21208MU216 was added to line S21208M valve S21208MUO31. His also required changing drain vahe S21208MR050 from a buttjoint Kerot valve to a socketjoint Henry Vogt Mark iO8 gate valve. In lieu ofperfonning a hydrostatic pressure test as required of ASME XI for this work, a system leakag conducted satisfactorily under the rules and requirements ofASME Code Case N-416-1. All NDE was perfo evaluated in accordance with Code Case N-416-1 requirements.

8. Tests Conducted: System 12akere Pressure Test Pres: 317 osir Temp:lQ5E p Svstem Functiona1 Pressure Test 317 osin 1 91. 6 a b b S

aiMyypygg v 547~ v-mw-(myrv .

                                                                                                                                        ;gg FORM NIS-2 (baek)
     ' Remarks : CR 3012-94 reconciles the replacement elbow, which was cenified to ASME III-2,1986 Edition, No

/ Addenda. we ,u m ma,.n. w-  : CERTIFICATE OF COMPLIANCE We cutify that the statements made in the report are cor" rect and this reoair and reelseement conforms to the rules of the ASME Code, Section XI. ry.itorreptucoxos - - - Type Code SymbolStamp: N/A , certificate ofAuthorizationNo: N/A ExpirationDate: N/A Siped: /2/' 2 Sunervisine ASME CodesEngineer Date: G /6!9T ' Owner'or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of Califormia. and employed by Arkwriebt Mutual Insurance Comeanv (Factory Mutual ed the components described in this Owner's Report En eineerine Associatien) during theperiod //-/f- eP/e/ of Norwood. to Massachusett: havp ig'6 . and state that to the best of my knowledg 6/6/4 belief, the Owner has perfonned examinations and tafcen corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owmer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or aloss of any kind arising from or connected with this inspection. [ /JnfE24/pt ' Commissions NMO Californie National Board, State. Province, and Endorsements Inspector's Sipaturef/ Date _ , f. MillWS b ,o h e _ a__

FORM NIS.2 CWNER',S A. a.pi ,4 y seREPORT r,.es .tn.FC R REPAIRS OR REPLACEMENTS Asxc c.4. s s.a x1 m '

/    }.                                                                                                              Sheet I ofI

\ / 1. Ommr: Southern CnLfornia Edison Company Unit: 2 2244 Walnut Grove Asense,Rosemead.CA 91770 CWO: 94082325000,94071412000, 94071412001

2. Plant: San Onofre Nuclear Generating Staden DCP: 249ts.00SN,Rev. 0 San Gemente,CA 92674-012s Palp: 40114D , ,

b' 5: $21204 34 ,

3. Verk Perfctmed by: Bechtel Construction Company Repair Spee: 6988 2-94,Rev.1 P.O.Bez d50 San Clemente, CA 92674 0123 . TypeCodeSitobolstamp: N/A AuthernadenNo: N/A
4. Idendfication ofSpiern: SafetyInjection(1204) Expiration Date: N/A
5. (a) Applicable Construction Code: ASME SeedonIII, Class 2,1974 Edition, S'74 Addenda, Code Casest None (PIptng)
           ,                             ,                                  ASME SectionIII Claas 2,1983 Edition, S*$3 Addenda, Code Cases: None (Valve)

(b) Applicable Edition of Seedon XI Utilized for Repairs or Replacements: 1989 EdItlon, No Addenda

6. Identificadeo of Cornponents Repaired or Replaced and Replacement N&

ASME Repaired, Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No. Board No. Repta-t Identi5 cation Built Yes/No Piping Subassembly Puttman N-3250 N/A Spoo1 #2.S!-048 003 1977 Altered Yes item t9 4' x 3/4' 3000# S.S. SA.182 Gr. P316 Sockolet W.F.I., Inc. HT #775VNA N/A N/A RSO #1396-94 Rehent No item #10 Consolidated SA-376 TP316 CX 3/4* Seit to S.S. Pipe Power Supply HT #461457 N/A RSO #3227-93 N/A Replacement No k  ! Item #11 I S21204 MR.446 3/4* S.S. SW Oate Vafve Anchor Darling S/N E326517 9 N/A RSO #0543-90 1990 Replacement Yes

7. Desaipdon ofWork: Vent vah S21204MR446 mas added'to line $21204M1h48 to facilitate the performance ofIST on 2HV9347 and 2HV9348. Mataial verification and prefab under CWO 94071412, *msta!!ation and NDE under CWO 94082325.

Dramings: ISO-S2-1204 MIA4t, Rev.13,1DCN S.1 i Valve.$0123 408 4 23

                                                                                                                                                                               ]
8. Tests Conducted: SysternLeakage[} 5)stemPunctional[X) SpiemInsenice[} Hydrostade[} Pneumatic [] Other[]

Pressure:960psig Temp:N/A i 4 b\ U Note: Supplemental sheets in the form oflists, sketches, or drawints may be used prodded (1) size is 3 % ist x 11 in (2)informa*. ion in items I threvgh 6 on this report is included on each sheet (3) each sheet is numbered and the number ofsheets is rscorded at the top of this form, and (4) each sheet is initialed and dated by the Owner or Omner's Designes and the AI A.

i F8RM NIS-2 (b:ek)

9. Remarks:

The replacement valve wu certified to a higher code class, ASME III.I. as aflouwl per ASME III, paragraph NCA-2134. T (Applicable Manufacturers Data Reports to be a: ached) CERTIFJCATEOFCOMP11ANCE ,* ,' We cenify that the catements made in the report are correct and this re01:eement confonns to the rules ofthe ASME Code, Section XI. Type Code SpnbolStamp: N/A

  • Certificate ofAuthor'zation
                            .        No: N/A                  Egiration Date: N/A Signed-                    /                 .Supenfrine ASME Codes Enrine r Desipes,Tr.le Date:      8         19M            Ouner or Owner's i

CERTIFICATE OFINSPECTION I,the undersigned holding a valid comrnission issued by the National Board ofBoiler and Pressure VesselInspeders and the State or Cahfornis. and employed by Arkmicht Mutug Insurance comnanv (Feetory Mutual En-incerine Associstfoni ofh*erwood. Massachmetts have inspeced the components desen' bed in this Owner's Report during the period /J? -SR - Wto 6/4 /d4"" . and state that to the best ofmy knowiedge and beliet the Ouner has performed exanunations and taken corrective measures described in this Ouners Reportin accordance with the requirements of the ASME Cade, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, egressed or implied, concerning the exardna corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any m personalinjury or damage or a loss ofany kind rising from or connected with this inspectioit A&M - Commissions b California inspeee<s sipature r

                                                                                      <xational Bond, State, Province and r     -i> >                  I      -

Date _ id h a 19QT.

            /                 '

s t

f-~ -..

                                                                                                                                                                                    ]
           ~ ~~.

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS as R.ptr.ny a. rresa. .t ausur c.a. snu. It > Sheet 1 of1

1. Owner: Southern Californla Edison Company Unit: 2 2244 Walnut Cros e Avenue,Rosemead,CA 91770 CWO: 94082326000,94071412000, 94071412001
2. Flard: San Onofre Nuclear Genersdng Stadon DCP: 2 6988.00$N,Rev.O San Cemente,CA 926744128 - P&lD: 40114D '
                                                                                                                     ~ N 5:          S2-1204 34
3. Work Performed by: Bechtel Construeden Company Repair Spec: 6988-2 94,Rev.1 F.O. Box 450 San Cemente, CA 926744128 T3ps Cole Spbol Stamp: N/A AuthernationNo: N/A 4 Identification of System: SafetyInjection(1204) Expiration Date: S.'A
5. (a) -l Applicable Construction Code: ADIE Section III, Class 2,1974 Edidon, S'74 Addenda,, Code Cases: None (P! ping)

ADIE Section XII, Class 2,1983 Edidon, S'83 Addenda, Code Cases: None (Valve) (t) Applicable Edition of Sec. ion XI Utilir.ed for Repairs or Replacements: 1989 Edidon, No Addenda

                                                                                                  ~
6. Identification of tys. Repaired w Replaced and Replacement Components:

ASME , Repaired, Code Name of Name of Manufacturer National O:hcr , Year R placed,or Stamped Component Manufacturer SerialNo. Board No. Identification BuDt Replacement YesNo Pipe (Mat!'l Onfy) Bal *ock & WUcox HTiM0671 N/A Spool #S2-S!452 007 N/A Aftered No item #12 4" x 3/4* 3000# S.S. SA-182 Gr.F316 Sockelet W.F.1, Inc. HT #775VNA N/A RSO #1396-94 N/A Replacement No Itern 413 l l Consolidated SA 376 TP 316 3/4* Scft 80 S.S. Pipe Pont Suppty HT #461457 N/A RSO #3287 93 N/A Replacement No

                                                      .                                                      Item #14 '

S2-1204-MR-445 3/4" S.S. SW Gate Valve AnchorDarling S/N E326517-10 N/A RSO #0543-90 1990 Replacement Yes

7. Description of Work: %nt Valve S21204MR445 was added to line $21204MI.D$2 to facilitate performance ofIST on 2HV9306 and 2HV9307. Material verification and prefah under CWO 94071412,ir*Ltion and NDE under CWO 94082326.

Drawings: !$0-$21204.MIA32, Sht 1, Rev. 9,IDCN S-1 Valve SO123-4084-23

8. TestsConducted: SpiemLeakage[] SpiemFunctiersJ1X] SyrenIrmervice[] Hydrostatic [] Pncumatic[] Other[]

Pressure:987psig Temp:N/A 1 ' l 1 l l l h l g i Note: Supplemental sheets in the farm oflists. sketches, or drswings may be used provided (1) size i: 8 % in x 11 in.,(2) Information in Items 1 through 6 on Wis report is included on each sheet. (3) each sheet is numbered and the number of sheets is recerded at the top of this form, and (4) i, each sheet is initiskd and dated by the Oner or Oner's Designes and the AIA

e l v

    !                                                                   FCRM NIS-2 (bsek)
9. Remarks: ne replacemers n1ve su certified to a Wgher code class, A$ e 'U.1, as anowed per ASME III, paragraph NCA.2134.

(Applicable Manufacturers Data Reports to he anached)

                                                                                                                '                                                    ~

CERTIFICATEOFCOMPLIANCE We certify that the ::atemert.s made in the report are corre:r and this reciscement confonns to the rules ofthe-ASME Code. SectionXL Type Code symbol Stamp: N/A Certificate ofAutiwr!aationNo: N/A Exp*r ation Date: N/A Signed:

                           /         2              Muservidne ASME Codes Enrine r                  Date-    /5 I .19 M                Owner or Owne/s Designee,TrW ' ' . *                                                                                ~l CERTIFICATEOFINSPECTION                                                        .

1,the undmignr.d holding a niid comaussion issued by the National Board of Boiler and Pressure Vessellarpectors and the State or Proece of

 ,,      C3fernia. and employed by Arbaht Mutual Insursnee comoan, &setery Mutual Endneedne Assoctsetor0 of Norwood.

1, Massselusetts have i tdh d ib d in this Owners Report duringthe period //-6 /- W / to f,9 //e/%ge e t e cc 4wients escr e. and state t% to the best ofmy know1 edge and belief,the Owner has performed exam measGres described in this Owners Report in accordance with the requiremeru ofthe ASME Code, Section XL By signing this cert 3cate, neither the Inspector nor his employer makes any svranty, ex;ressed er implied concerning the examinations and conective n

  • wares described in this Owners Report. Fur.hermore, neither the Inspector nor his emplo)w shan be liable in any manner for any pmonalirsury er pr ,erty ge or a loss ofany kind arising from or connected with this inspection.

A/ Ads 71 y Commissions /I M Califomia _ ins,ea ss % e cuon.i Boa,4 stase.t,gnee. and tnd-Date 24U b ,- 19 s y - i i 1 1 4 I

                                                                                                                                                                       -  i 1

e" asa.;. . -. FMI NIS.2 OWNER'S REPORT FOR REPAIRS CR REPLACEMENTS As amtw h m re.vu.= .t e Asatt c.d. s es.a xt

        ^

1 j - Shed1of1 7

 \' '/
1. Oncri Southern Californ!n Edison Company -

2244 Walnut Grove Avenue, Rosemead, CA 91770 Unit: CWO: 2 94082327000,94071412000, 94071412001

2. Plant: San Onofre Nuclear Genersdng Staden DCP: 2 6988.00$N,Rev.O San Cemente, CA 92674 0128 P&lD: 40112B ,
                                                                                                              ~~ RepairSpee: 683 3-94,Rev.1
3. Work Perfanned by: BechtelConstrueden Compary P.O. Box 450 T 3pe Code 5)Tnbol Stamp: NA San Cemente,CA 926744128 AmhonzationNo: N/A Exp'ration Date: N/A
4. Idraification of 53stem: Safety Injection (1204)
5. (a) Applicable Construsion Code: ASME Seedon III, Cass 2,1974 EdIden, S'74 Addenda. Code Cases: None (Piping)

J'

                                                                      . ASME Seedon III.Oss 2,1974 EdJtion, S'i5 Addenda, Code Cases: None (Valve)

(t) . Applicable Edition of Section XI Utilized for Repain or Replacements: 1989 Edidon,No Addenda

6. IwWon of Components Repaired or Replaced and Replacement Components: .

ASME Repaired, Code Name of Name of Ma*ufacturer National 0:hcr Year Replaced, or Stamped e- Manufae:urer Seria1 No. Board No. Identification Built Replacement Yes'No Piping Sub.Assemb)y . Bechtel N/A N/A Spool #2.SI.0501 N/A Altared No* Itern #47 , 3" x 3d.' 3000# S.S. S.4182 Or. F316 Sockolet WH Inc. HT#775VNA N/A RSO #1396 94 N/A ' Replamment No Itern #48 [

          ;                                     Consolidated                                           SA-376TP 304 1/4" Sch 40S S.S. Pipe             Power Supply      HT#9E4490                  N/A       RSO #3287 93             N/A         Reptscement          No
                                                           .                                           Item #49 1/4" 6008 S.S. SW Gate              HcnryYogL                                             S21204.MR.447 Valve                             Machine Co.        S/N 10-216845             N/A       RSO #2048 93             1993        Replacement          Yes
7. Desenption of Work: Drain ulve S21204MR447 ns added to line S21204M1450 to facilitate perfonnance ofIST on 2HV 162. Material veification and pre. fab under CWO 94071412, installation and NDE under CWO 94032327.

Drawings: ISO.S2 1204-MIA50, Sht.1. Rev.10, IDCN S.2 Valve.SO23 408110 49 & 182

8. TestaConduced: Systemf.eakage[} SysternPuncional[X) SystenInsernce[] Hydrostatic [] Pneumatic [] Other[]

Pressure: 503 psig Temp:N/A

  • Spool insta!!ed under Sec. XI, DCP 29N, not listed on any N5, b

1 i Note: Supplemental sheets in the form oflists, sketches, er drawings may be used provided (1) size is t % in, u 11 in.,(2)information in Items I through 6 on this report is included on each sheet,(3) each sbect is numbered and the number of sheets is recerded at the top of this form, and (4) each sheet is initiated and dated by the Owner or Owweri Designee and the A1 A. l

MNII~hMs4MMDj@ckh[jgE*i:,4)?jfY4 *'P.kWM';YD i' NCR$NpI 'l y f - ,

                                                                                                                                                                           )

1 FORM NIS-2 (back)

 ,/   9.          Remarts: None.

I (Applicable Manufac:uref: Data Reports to be anached) CERTIFICATEOFCOMPLIANCE

  • We certifythat the statements made in the report are correct and & reviseement conforms to the rules of ths ASME Code, SectionXI.

Type Code symbol stamp: N/A Certi5cate ofAuthorizationNot N/A Expiration Date: N/A M~ ~ Signed: . unervisine ASME Codes Endneer Date: [ 19 f,f Ouner or Ouners Designee.T% , CERTIFICATE OFINSPECTION I,the undersigned bolding a valid commission issued by the National Board of BcDer and Pressure vessel!nspectors and the State or Prosince of ofNorwood. Californft and employed by Arhti+ht hfutualInsurance Company (Fortory hfutual Eneineerine Associstfon)1-to i

         }le/6./ 9 6f assachusetts                   have
                                      . and state that to the inspected      the and best ofmy knowledge components belief,the Ownerdescribed       in this Ounefs has performed mmmanons   and taken Report corrective during the period meisures described in this Owne/s Reportm' accordance with the requirements of the A$hE Code, Section XI.

f By signing this certificate, neither the lnspector nor his employcr makes any w arranty, expressed or implied, concerning the exanunations and corrective rneasures described in this owners Report. Furthennore, neither the Inspector nor hL employer shall be IIable in any manner for any l l personaliryuryor damage or a loss of any kind aris"mg from or connected with this inspection.

                               # h M dCPT                                                 Commissions N                          Califomia inspedor's Signature /                                           (National Board, State Province, and Endorsements )

Date , /A4d_ ( o. ., 19hT O

                                                                                                                                                                                         ~;..- -.;

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required br Ow Pminans erem ASM1 Ceds SenernX) Shousl of f

1. Owner: Southem Califomia Edison Company Unit: 2 cs 2244 Walnut Grove Avenue MO: 94082421000,95031402000

( ) Rosemead,Califomia 91770 DCP: 2-6683.04SP Rspec: 062 94

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 PalD: 40141C N-5: S2-1301-2
3. WorkPerformedby: Southem Califamia Edison Company T3pe Code Symbol Stamp: N/A
4. Identification of System: Main Steam Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Constn.iction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Namut Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Seria1 No. Board No. Idemification Buin Replacement Stamped YesSo Mechanical Snubber Pacific Scientific 132 N/A S2ST002H026 N/A Replaced No PSA 100 - 6 36' Rigid Stnit Lisega S2-ST-002 H 026 N/A RSO 0030-95, N/A Replacement - No 3992RR1S CR-2000-95 Load Pin ITT Grinnell Ht. Code B7 N/A RSO 1820-85, N/A Replacement No l SA-193 Gr.B7

                                                                                                                                                                                                   \

[m)

7. Description of Work:

The mechanical snubber was replaced with a rigid strut in accordan .e with DCP 2 6683.0(SP. The existing attachment brackets were reused. A damaged load pin was identified and replaced (MO 95031402). A VT-3 examination was performed after installation. The removed snubber was placed into the snubberrebuild program.

Reference:

Stress CalculationM-1301-002-4A (PSG-14)

8. Tests Conducted: N% Pres: Ff% Temp: N/A
  .m
     \

NOTE. Swedesmental sheet m en fann erbsst sW ar drewmss may be used prended (1) ser s B la A a al m o)afannesen a tiens i Orogh 6 on em repen e included on each sheet. 3J east shes s -

                                 .4 and Pe niunbe ofshsem in seeseded as se top of om fanst aid (d) each absei a sanned and esied by tw ommer er Oumers desense and 9m A1A.

FORM NIS-2 (b ek)

9. Remarks : The replacement load pin was certified to ASME III-1-NF.

vw~u ume. u. w w .m O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Starrp: N/A Certincate of Authorization No: N/A Expiration Date: N/A Signed: IM Owner or Owner's Designee, Title Sunervisine ASME Codes Encinem Date: Y

                                                                                                                       /'

9f CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comcanv (Factorv Mutual Enrineerine Association)

          /22//S/ of,O(ZNorwood. to # / /,l    Massachusetts
                                                   / 9 5               have inspected the components described in this Owner's Re
                                                                 . and state that to the best of my knowledge and belief, the Owner has perfon6ed e/ammations and take6contctive measures described in this Ownen Report in accordance with the requirements of le ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warra.'ty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Furthermo t, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kl.,d arising from or connected with this m8Pection.

                         //3 y M d/f>t                    Commissions         (([I                           Califomia Inspector's Signa' tuff                                           National Board, State, Province, and Endorsements Date hAAY                 , )h(

f . m.umma

  ;                                                                                                                                                                                       l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A. a.e-d by o. Pr emas d$u A$ME Cade SanmM                                                                  '

Shen I of t

             .1. Owner: Southem Califomia Edien Company                                                                              Unit: 2                                                 j
    .rN.                        2244 Walnut Grove Avenue -                                                                          MO:         94082425000
                              - Rosemead, Califomia 91770

(~ DCP: 2-6683.04SP Rspec: 061 94 12.' Plant: San Onofre Nuclear Generating Station ' P&ID: 40141C San Clemente, Califomia 92674-0128 N-5: S2 1301-2 [ - 3. Work Perfonned by: Southem Califamia Edison Company T3pe Code SymbolStamp: N/A .j h 4. Identification of System: Main Steam ^" ^ j E D ' l.

5. (a) Applicable Construction Code: ' ASPE Section IIL Class 2-NF.1974 Edition. S*74 AAAmda. Code Case: None -

'- (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components: .
                                                                                                                                                                                           ]
                                                                                                                             .                               Repaired,       ASME Namn(                        NameOf-                                                                                                                                 '

Manufacturer National Odwr Year . Replaced or Code Component . Manufacturer Serial No. Board No. Identification Built Replacemerd Stamped j i Yes/No a

 ~

Spring Can ITT Grinnell S2-ST-002 H-013A N/A S2ST002H013A N/A Pennanently No i Deleted  ; Spring Can. ITT Grinnell S2 ST-002 H-013B N/A S2ST002H013B N/A Pennanently No Deleted

7. Description of Work:  :
        )       The spring cans and slide bearing pads were no longer required per the latest pipe stress calculation M 1301-002-4A s  /       (PSG 14) and were permanently removed in accordance with DCP 2-6683.04SP. Miscellaneous attachments were left in place.
8. Tests Conducted: N/A Pres: U!% Temp: Uf%

_ _.-._____....,_h._.d.n_ 3)ensk aben a snsubend and the nenha .f shese a reemend m en top e($us % and (4)auch shen b x +. / end duend by die Ones es owners endsnee and tw ALA.

FORM NIS-2 (baek)

9. Remarks : None.

(AppiuWe Mmaasfurers Ents Esptwu b be atwhed) O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this , - deletion confonnstothe rules of the ASME Code, Section XI. repair or replacement Type Code S3 Tnbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: M*b Owner or Owner's Designee. Title Sunenisine ASME Codes Encineer Date: '/ f CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arl<wricht Mutual insurance Company (Factorv Mutual Eneineerine Association) of Norwood. Massachusetts 1 ave inspected the components described in this Owner's Report during the period Md/7/94 to #/#/95~~ . and state that to the best of my knowledge and belief, the Owner has perfonsed 6xaminations and takes cor(ective measures described in this Owner's Report in accordance with the requirements of

     ' e ASME Code, Section XI.

l By signing this certificate, neither the Inspector nor his employer makes any wananty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connectM with this mspection.

                            /}s/L4//>r       ~

Commissions /I48 Califomia inspector's'Signatud National Board, State Province, and Endorsements Datch

              /

Y. /$$ I J l l l 1 1 1 1 90: ses2csooo e!I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A a -a er e >== are. ASME Code $emmU

                                                                                                               $ bass I er1 1.- Owner. Southern Califomia Edison Company                                                Unit: 2

[~ T - 2244 Walnut Grove Avenue MO: 94082528000 () Rosemead, California 91770 DCP: 2-6683.04SP 4

                 - 2. Plant:       San Onofre Nuclear Generating Station
                                - San Clemente, California 92674-0128                                          P&ID: 40141C N-5:          S2-1301-2
3. WorkPerformedby: Southem California Edison Company Type Code Symbolstamp: N/A.

Authorization No: N/A

4. Identification ofSystem: Main Steam EvirationDate: N/A -
5. (a) Applicable Construction Code: ASME Section III. Class 2-NF_1974 Edition: S*74 Add: xia_ Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No AAAamin
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name'of Name of Manufacturer National Oiher Year Replaced or Code Componses Manufacturer Serial No. Board No. Idenuficanon Built Replacement Stamped Yes/No Mechanical Snubber PaciSc Scientific 36644 N/A S2ST002H041 1984 Permanently Yes . PSA 1/4 Deleted Mechanical Snubber Pacific Sci ntific 5320 N/A S2ST002H046 1979 Permanently Yes PSA 1-4 Deleted

7. DescriptionofWork:

h V The mechanical snubbers with attachment hardware were no longer required per the latest pipe stress calculation M-1301-002-5A (PSG-351) and were permanently removed in accordance with DCP 2-6683.04SP. The rear brackets were left in-place. The removed snubbers were placed into the snubber rebuild program.

8. Tests Conducted:N!% Pres:N/B Temp:N/%

v f- 3) e end AYe.="eeware dYous per No iU and en.4[emode o dessen b N

FORM NIS-2 (brck)

9. Remarks : None.

m umca uaa, n. a a.aa> O CERTIFICATE OF COMPI.IANCE We certify that the statements made in the report are correct and this deletion confonns to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Cenificate ofAuthorization No: N/A Expiration Date: N/A Signed: M b Strnervisine ASME Codes Encineer Date: 4I/96 Owner or Oumer's Designee, Title ' CERTIFICATE OFINSPECTION I, the undersiEntd holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insursnee Comnany Factorv Mutual Encineerine Association) of Norm ood. Massachusetts have inspected the components described in this Owmer's Repon during the period 12/06/S4 to 3//5/95 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any wan anty, expressed or implied, conceming the examinations and corrective measures described in this Owmr's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this

nspe(tion. s n

td - G Commissions Califomia f 57f Inspector's Signature National Board, State, Province, and Endorsements Date M 4,'l995 c./ 1 1 1 1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Reemrod by em Pnmssons ersw d.5ME code seces00 sheet I ofI

..        1. Owner: Southern California Edison Company                                                                                      Unit: 2

- f"T 2244 Walnut Grove Avenue MO: 94082529000. V Rosemeado California 91770 DCP: 2-6683.04SP i Rspec: 077 94 2 - Plant: San Onofre Nuclear Generating Station P&ID: 40141C San Clementes California 92674-0128 N-5: S2-1301-2

3. WorkPerformedby: Southern California Edison Company Type Code Symbol Stamp: N/A
4. Identification of System: Main Steam Authorization No: N/A Expiration Date: N/A'
5. (a) Applicable Construction Code: ASME Section III. Class 2 NF.1974 Edition. S*74 Addenda. Code case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Nameof Afanufacturer National other Year Replaced or Code-Componers hianufacturer Serial No. Board No. Identification Built Replacement Stamped ' Yes % f Mechanical Snubber Pacific Scientific 33872 N/A S1ST002H040 1984 Replaced Yes  ; PSA 1/4 i 30' Rigid strut Lisega S2ST002H040 N/A RSO OO30-95, N/A Replacement No 3922RRIS CCaseN249 N71 1/4"x1/2"xi1/2* Energy & Process Heat 412A0101 N/A y RSO O393-95e N/A Replacement No Lues (2) Corp. - i SAS16 Gr 70

 \   7. Description of Work:

The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. Two lugs were welded to the pipe using weld record WR2-94-362. The existing attachment brackets were reused. A VT-3 examinction of the support assembly was performed after installation. De removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M 1301-002 5A (PSG-351) i

8. Tests Conducted: N/% Pres: N]% Temp: N_%

E Nort Septemensel alweis si en forse orhsm, shenshan,er 4,wegs any te used psevded (0 ene s 8 l*J m a 83 m,c)' _ _

                                                                                                                                     -a hems I eragh 6 en tus repen a metuded en each sheet,
3) each sheet a senbseed and Wu msnha of shesu a veceseed el $e imp of sus im and (d) each sheet a subaled and daard by su Ommer er Owners dangnes and the A1JL

FORM NIS-2 (b:ck) l

9. Remarks : None.

m m= mm.m w. w u a .mwo CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstothe niles of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: < Supervising ASME Codes Encineer Date: M 96 Owner or Owner's Desicnee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Compar,v (Factorv Mutual Enrineerine A ssociation) of Norwood. Massnebuietts have inspected the components described in this Owner's Repon during the period

       / SAP /94/ to 4229/9& . and state that to the best of my knowledge and belief, the Owner has perfofmed damiriations and taken'co:Tective measures described in this Owner's Repen in accordance with the requirements of the ASME Cxle, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this utspection.

                  ~

Ah Insjatcir's SignatuF Commissions ~/8A California National Board, State. Prosince, and Endorsements Date $,Df/ *5 N6~

 .__                                                                                                                        g l

J

a

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS -

4.h ,.4w r- .rse ASW Can Sut.XI Sh.a i .ri

1. Owner: Southem Califomia Edison Company . Unit: 2  ;

2244 Walnut Grove Avenue MO: 94082530000 j

   /N).-

O. Rosemead,Califomia 91770 DCP: 2-6683.04SP. i

                                                                               .                                                               Rspec: 078-94                                              i
2. Plant: San Onofre Nuclear Generating Station PalD: '40141C
                                , San Clemente, Califomia 9267.4-0128                                                                                                                                     I N-5:         S2-1301-2                                      )
3. Work Pe: formed by: Southem Califomia Edison Company Type Code SymbolStamp: N/A
4. Identification of System: Mafn Steam Authori ation No: N/A ~

Expirstion Date: N/A.

5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case: None  !

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components: .

Repaired. ASME , Namettf Name Of Manufacturer National Oiher Year - Replacedor Code. , Component Manufacturer Seria1 No. Board No. Identification Built Replacement Stamped t YesWo Mechanical Snubber Pacific Scientific 37448 N/A S2ST002H042 1986 Replaced No PSA 1/4 221/4* Rigid Strut Lisega S2 ST-002-H-042 N/A RSO 0030-95 N/A Replacement No . , 3922RR

  • 1/4* x t/2* x l 1/2* Energy & Process Heat 412A0101 N/A; RSOO393 95, N/A Replacement No Lugs (2) Corp. i SA516 Gr.70
  .b
   \j     7. Description of Work:

The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. Two lugs were welded to the pipe sides using weld record WR2-94 363. The existing attachment brackets were reused. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M 1301-002 5A (PSG-351) i 4 s

                                                                                                                                                                                                          ?

l

8. Tests Conducted: HB Pres: Ha Temp: NJA
           - --. _ . _ m......,_                                                                                                            ~               h...-.-.-
3) each shes a numbered and tw assaner ofeksen a sesorded at sw hy of the farm, and (4)eesh shna o emmened and disse h su owner as owners daugnse and 9e AIA. '

5

p ' l FORM NIS-2 (b:ck)

9. Remarks : None.

e e . nut.n m up  % 9\ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: / b Stmervisine AShE Codes Encineer Date: #Nb5 Outer or Oumer's Desicnee. Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Company (Factorv Mutual Encineerine A ssociation) of Norwood. Mass schusetts have inspected the components desenbed in this Owner's Report during the period

       /f/AP/9// to #fMFC . and state that to the best of my knowledge and belief, the Owner has perforfned daminat' ions and takefi con'ective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Oumer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this mspection.
               /            AAdor                       Commissions MEC2.                               Califomia Inspe7c Ters'signatufe /

National Board, State Province, and Endorsements Datch,b/ c_T /WS W O o a__ e

V i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regwed by tie Fevuiens ef ew A$Mt Code SecuenXI Siwst 1 ofI

  -    'l. Owner:' Southem California Edison Company                                                                               Unit: 2

[N 2244 Walnut Grove Avenue - DCP: 2-6683.04SP . sj Rosemead, California 91770 MO: 94082532000 Rspec: 062 94

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&ID: 40141C -

N-5: S2-1301-2

3. Work Perfonned by: Southern California Edison Company Type Code Symbol stamp: N/A '
4. Identification of System: Main Steam Authorization No: N/A Expiration Date: N/A
5. (a) ApplicableConstructionCode: ASME Section III. Class 2 NF.1974 Edition. S*74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda  ;
6. . Identification of Component * .iepaired or Replaced and Replacement Components: -
                                                                                                                                                      ' Repaired,         'ASME Name of                     Name of                   Manufacturer            National                 Other                Year    Replaced or          Code Component                    Manufacturer                 ' Serial No.          Board No.              Identification        . Built  Replacement Stamped YeWNo Mechanical Snubber              Pacific Scientific         5321                             N/A'           S2ST002H047                 1979     Replaced             Yes PSA 1-4 451/2" Rigid Strut              Lisega                     S2-ST-002-H-047                  N/A           RSO 0030-95,                 N/A Replacement               No 3932RRIS                                       CCase N249, N71
7. Description of Work:

(9 () The mechanical snubber was replaced with a rigid strut in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT 3 examination of the support assembly was perfonned after installation. The removed snubber was placed into the snubber rebuild program.

Reference:

Stress Calculation M 1301-002 5A (PSG-351) l t

                                                                                                                                                              .                     ?

I R

                                                                                                                  ,e
8. Tests Conducted: M Pres: M Temp: M
m
      -        -.-~~.-,dm...,,.                                                                                               . - ,e         . ~ ,
3) seek shes b - d .h
                                    ? and an amiske of shens b nearend si su tap of tus sammt and (d)each ehese a bunal.d and emed by en owner er oe'ner's daup=se and tw AIA.

1

FORM NIS-2 (b:ck)

9. Remarks : None.
                                                      + w u.nma.m eu,uaam CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI.                                         repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A                         Expiration Date: N/A Signed:       ##d/M                                  Supervisinc ASME codes Enintg                 Date:         Y      .F5 Owmer or Owmer's Designee, Title CERTIFICATE OF INSPECTION                                        .

I, the undersil;ned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnany (Factorv Mutual Encineerine Asmistion) ofNorwood, Massschusetts have inspected the components described in this Owner's Report during the period

         /4/M/94                  to    4/#/9C                  , and state that to the best of my knowledge and belief, the Owner has perforfned efaminations and taken t!orre'ctive measures described in this Oner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Oner's Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection [ ' AM Conumssions /[/IJ2 Califamia inspector's Sigrfature/ National Board, State, Pro ince, and Endorsements Date h,8 h f k, / N C l l i _ a__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS um ar= % <=4mec.us m

1. Owner: Southern CaliforniaEdison Company Unit: 2 2244 Walnut Grove Avenue MO: 94082566001 Rh. California 91770 FCN: F10154M
 - ~)(V-                                                                                                        Rspec : 063-94 R1
2. Plant San Onofre Nuclear Generating Statim San Clemente, California 92674-0128 P&ID: 40156C H-5 N 5: S2-1305-8
3. WorkPerformedby: Southem Califomia Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identi5 cation ofSystem: Feedwater ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 (Elbow & Tubinet s'75 A A%cta (Valvel CodeCases None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements. 1989 Edition.No AdA=4=
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared, ASME Name of Name of Manufamner Natiemal Otbar Year Replaced or Code cornponent Manufacturer - SerialNo. Board No. 1Ma'W Built T- ^ Stamped YeeWo 3/8" Isolation Valve Gould Inc. 23730 N/A 2PI4048M 1979 Replaced Yes In-usst Valve 3/8" Isolation Valve Anderson N89277 N/A RSO 1307-93, 1993 Replacement Yes Greenwood CR-89-003 3/8" Elbows (3) Parker-Hanmfin Ht Code UBBH N/A RSO 1090-94, Part N/A Replacement Yes 6-6-EBZ-SS 3/8" Tubing Hub Inc. Heat 460342 N/A RSO 1760-89, N/A Replacement No SA-213 TP 316

7. Description of Work:

The instrument isolation valve for 2PI4048M was leaking by and was replaced. The replacement valve was changed from a Gould valve to an Anderson Greenwtxxl valve in accordance with FCN F10154M. This also required the replacement of the tubing unions and elbow due to the difference in the valved configuration. t i l 1

8. Tests Conducted: System Functional Pressure Test Pres: JJl1Qpsig Temp: M i

lTd"U.'."*230L"#a"!L',L"l'Ui l'<%%"llff.!M.F M/="~o ' W O,f,1*'d' ""* M1 -

                                                                                                                                  #e                             #

FORM NIS-2 (b:ck) -

9. Remarks:

CR-89-003 reconcDes the replacement valve which was certifed to ASME III-2,1983 Edition, STS Addenda. v __ , m m - m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reelectment conformstotherules of the ASME Code, Section XI. npair ernotacemece Type Code SymbolStamp: N/A Certi5cate ofAuthorization No: N/A ExpirationDate: N/A Signed:_[/ /M Stmervisine ASME Codes Encineer Date: Ma/W

                                                                                                                       ~

Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commi" ion issued by the National Board ofBoiler and Pressure Vesse the State orProvince of Califormla. and employed by Arkwriebt MutualInsurance Comoany Gaetory Mutual En clocerine Association) duringtheperiod M/f9X94 of Norwood. Massachusetts hafe m' spected the components described i to '7//-7X9h . and state that to the best of my knowledge and belief, the Owner has pe' rfarnied exammations and taken corrective measures described in this Owner's accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any wananty, ap 2 orimplied examinations and corrective measures desaibed in this Outer's Report. Fmthermore, neither the Inspector norh employer shall be liable in any manner for any personal injury or propaty damage or a loss of any kind arisin

                                     &                   Commissions / de'2-                        California Inspector's Signature /

National Board, State, Provmee, and Endorsements

                                                            .s Dat _          _ $3fc9M                              '
              /       O e

e e m N$ M e G ig

                   'ed

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Ragused by su Preimens ef te Ashff Code SestemXI Sheet I ofI

         . 1. Owner: Southem California Edison Company                                                                       Unit: 2 2244 Walnut Grove Avenue                                                                          MO:       94090086000
   '/ 9                       Rosemead, California 91770 DCP: 2-6683.04SP
   '( /-                                                                                                                       Rspec 062-94                                        >
2. Plant: . San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 P&ID: 40122B N 5: S2 1219-4
3. Work Performed by: Southem Califomia Edison Company Type Codes)TnbolStamp: N/A
4. Identification of System: Refueling Water Tanks Authorization No: N/A Expiration Date: N/A i
5. (a) Applicable Construction Code: ASME Section IIL Class 2 NF.1974 Edition. S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                                                                                      ~

Repaired. ASME Namg,cf Name Of hianufacturer National Other Year Replaced or Code Component Efanufacturer Serial No. Board No. Identification Built Replacement Stamped , Yes/No Mechanical Snubber Pacific Scientific 4445 N/A S2FS107H006 1978 Replaced . Yes PSA 1-4 141/2' Rigid Strut Lisega S2-FS-107 H-006, N/A RSO 0030-95, N/A Replacement No 3932RRIS CCase N249, N71

      . 7. Description of Work:

The mechanical snubber was replaced with a rigid stmt in accordance with DCP 2-6683.04SP. The existing attachment brackets were reused. A VT 3 examination of the support assembly was performed after installation. The removed snubber

    '%.        was placed into the snubberrebuild pregram. 

Reference:

Stress Calculation M 1204-080-AA (PSG-205)

8. Tests Conducted: N% Pres: N_% Temp: N/%

hM SasPp6smeMal ahere a the fann erkan.oW es 6 =wgs may be emed prended (t) ene s 8 t/2 st a Il m, C)mfanneman a hesns i ereueh d en es repset a usteded em sech sheet,

3) each sheet a membered and se member ernhese a susweed as the kg of ses ferns and y)each shest a sueeled and daled by the owner er 0% deegnes and the AR

FORM NIS-2 (back)

9. Remarks : None.

ww u.nme, we s. .n.a a, O CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A , Signed: / 2/ h- Sut>ervisine ASME Codes Encineer Date:

                                                                                                                  /'

Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersi6ned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutt at Insurance Comoany (Factorv Mutual Eneineerine Association) of Norwood. Massschusetts have inspected the components described in this Owner's Report during the period

       /2//6 /94             to      3/29/95               . and state that to the best of my knowledge and belief, the Owmer has performed exammations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By sigring this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector ner his employer shall be liabic in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspecti a
              %                    C      1         Commissions                                        Califomia I67I Inspector's Signature                                             National Board, State, Prosince, and Endorsements oate      4/4/w I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS  ! As Required by Ow Promissa of the ASME Cods Sacher03 .l Shem I ofI )

1. Owner: Southern Califomia Edison Company - Unit: 2 3
  /N                     2244 Walnut Grove Avenue                                                                       DCP: 2-6683.04SP                          :

C ' Rosemead, California 91770 MO: 94090088000 Rspec: 062-94

2. Plant: San Onofre Nuclear Generating Station
                                                                                                                      ' P&ID: 40122B                             l
                     . SanClemente,Califomia 92674 0128 N 5: S2 1219-4
3. WorkPerformedby: Southem Califomia Edison Company Type Code Spnbol Stamp: N/A
4. Identification ofSystem: Refueling Water Tanks Authorization No: N/A ExpirationDate: N/A.

l S. (a) Applicable Constmetion Code: ASME Section III. Class 2-NF.1974 Edition. S'74 Addenda. Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of NameOf Manufacturer National Chher Year Replaced or Code ' Componers Manufacturer Serial No. Board No. Identification Buik Replacement Stamped Yes!No Mechanical Snubber Pacific Scientific ~ 4686 N/A S2FS107H007A 1978 Replaced Yes PSA 14 Mechanical Snubber Pacific Scientific 4685 N/A S2FS107H007B 1978 Replaced . Yes PSA 1-4 13 3/4' Rigid Stmts 1.isega S2 FS-107 H-007, N/A RSO 0030 95, N/A Replacement No (2) 3932RR1S CCaseN249 N71 (,/ 7. Description of Work: The mechanical snubbers were replaced with rigid struts in accordance with DCP 2-6683.04SP. Existing attachment brackets were reused. VT-3 examinations of the support assemblies were performed after installation. The removed snubbers were placed into the snubber rebuild program

Reference:

Stress Calculation M 1204-080-AA (PSG-205)  ; 1 l I

8. Tests Conducted: N!% Pres: N]/A Temp: N]%

i

======e:.======.~o= ==-

FORM NIS-2 (b:ck)

9. Remarks: None.

e u-w.wi.up w.a, O CERTIFICATE OF COMPLIANCE We certdy that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp: N/A Ceruficate of Authorization No: N/A Expiration Date: N/A Signed: 8  ?. Stmervisine ASME Codes Encineer Date: 9 M Owner or Odmer's Designee, Title CERTIFICATE OFINSPECTION - I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insuranee Comnanv (Factorv Mutual Enrineerine Associatiot0 of Norwood. Massachusetts have inspected the components described in this Owmer's Report during the period

           /3/ /5/94              to 3/B8/f5                    . and state that to the best of my knowledge and belief, the Owmer has performed examinations and taken' corrective measures desenbed in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Furthermore, neither the Inspector nor his employer shall be liabic,in any manner for an, personal injury or propeny damage or a loss of any kind arising from or connected with this mspect on. ( (tth N k & ke'Y) Commissions Califomia 1574 Inspector's Signature National Board, State, Province, and Endorsements Date 1 l l

l: .

          ,'.       s.                     FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACDIENTS u n.cie.4 6r a
                                                                                 . re. s.s    .e 6. asur c.4.s.es n b
       \

f "- /. Sheet 1 of1

1. Ommer: Sonthern California Edison Company Unit: 2 2244 Walnut Crore Avenue, Rosemead, CA 91770 CWO: 94090173000
                                                                            .                                     DCP:         SG2,C8
2. Phnt: San Onofre Nodear Generating Station P&lD: 40141A' San Ckmente, CA 92674 0128 N-5: S2-1301 1
3. Work Performed by: Bechtel Construction Company 7ype Code Symbol Stamp: N/A P.O. Box 450 Authorization Nc:

i

                                                                                                                                                  -N/A San Clemente, CA 92674-0128                          Expiration Date:                 N/A L

l 4. Identification.of S) stem: Main Stearn (1301)

5. (a) Applicable Construction Code: ASME Section III, Class 1, l' 971 Edition, S'71 Addenda, Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Rephcements: 1989 Edition, No Addenda
6. Identification of Components Repaired or Replaced and Repheement Components:

ASME Repaired, Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No. Board No. Identification Built Replacement Yes/No

                  $21301.ME-088                   Combustion Steam Generator                 Engineering     71270-2                    22219              N/A            1976        N/A           Yes SA 193 Grade B7 Combustion                                            RSO 299191 Rev.1 1" Hand Hole $1ud (1)           Engineering     HT #85689                   N/A       CR 2001-93             N/A     Replacement        No SA 193 Grade B7
   /9             l' Hand Hole Stud Nut           Combustion                                            RSO 2249-91 (I             (1)                             Engineering    HT #11472                    N/A       CR-2001-93             N/A     Rephcement         No 7.

Desciption of Work: Remove and reinstaued S/O secondary handhole cover on 321301 ME OSS with a replacement stud and nut.

8. Tests Conducted:

Sptem 1.catage [X] S3 stem F.nctional [] System Inservice [] Hydrostatic [ ] Pneumatic [ ] Other [ ] Pressure: 983 psig Temp: 544*F l l l f3 Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form. and (4) each sheet is initiated and dated tw the Owner or Owner's Desirnee and the AI A.

FORM NIS 2 (back) 9. Remarts: CR-2001-93 reconciles the replacement stud, which mis cenified to ASME Ill-1,1974 Edition, W'74 Addenda and the replacement nut, which m3s certified to ASME !!!.1,1980 Edition, W82 Addenda. ~ (Applicable Manufacturer's Data Repons to be attached) CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this replacement conforms to the rules of the ASME Code, Section XI.

       "!)pe Code Symbol Stamp: N/A Ceni0cate of Authhtion No: N/A                                 Expiration Date: N/A Signed:                           /

Dun'er o'r Ommer's D'esignee, Title

                                                                  .Supervisine ASME Codes Enrineer           Date:      N  8
                                                                                                                                         .19M   s CERTIFICATE OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arhvirbt Mutual Insurance Company (Factorv Mutual Enrineerine Associadon) of Norwood. Mawchusetts have inspected the components described in this Owner's Repon during the period /A2/i///94/

to . E//g/(/6

                                   . and state that to the best of my knowledge and belief, the Owner has performed examfhations' and taken correcfive afeasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warrsnty, expressed or implied, concerning the examinations and corrective measures described in this Oumer's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damsge or a loss of any kind arising from or connected with this inspection.

v - AB8/2f- y Commissions I?M California Inspector's Signature (National Board, State, Province, and Endorsements ) Date WMA / , 19 b y < m

                                        . cr   iy                                                                                                         .
                                        - F'ORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1
a. n,+n s. s r w.u .t s. asus ca. s a n

( ,)

       \

Sheet 1 of 1

1. Oster: Southern California Edison Company Unit: 2 ,

2244 Walnut Grove Atenne, Rosemead, CA 91770 CWO: 94090289000

                                                                          ,                                  DCP:         SG2/C8
2. Plant: Sac. Onofre Nedear Generating Station P&lD: 40141A San Clemente, CA 92674 0128 N-5: S2 1301 2
3. Work Performed by: Bechtel Construction Company 'I)pe Code Symbol Stamp: N/A P.O. Box 450 Authorization No: N/A San Clemente, CA 92674-0128 Expiration Date: N/A
4. Identification of System: Mala Steam (1301)
5. (a) Applicable Construction Code: ASME Section III, Class 1,1971 Edition, S'71 Addenda, Code Cases: None (b) A"pplicable Edition of Section XI Ut!!ized for Repairs or Replacements: 1989 Edition, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

ASME Repaired, Code Name of Name of Manufacturer - National Other Year Replaced, or. Stamped Component Manufacturer Serial No. Board No. Identification Built Replacement Yes/No S21301 ME 089 Combustion ' Steam Oenerator Engineering 71270-1 22218 N/A 1976 N/A Yes j SA 193 Grade B7 RSO 2991-91 Rev.1 Combustion RSO 2249-91

 ,.~ ,           l' Handhole Stud (10)           Engineering     HT #85689                N/A       CR-200193               N/A    Replacement        No

! )l \, Combustion Engineering HT #11472 N/A SA 193 Grade B7 RSO 299191 Rev.1 CR-200193 N/A Replacement No l l' Handhole stud nut (1) l l l

7. Description of Work: Removed and reinstalled S/O secondary handbole covers on 521301 ME 089 with 10 new studs and one new nut.

I

8. Tests conducted: Sptem Leakage [X) System Functional [] System Inseniec [] Hydrostatie [] Pneumatie [] Other []

Pressure: 984 psig Temp: 544*F . f*'\i t V Note: Supplemental sheets in she form of lists, sketches. or drawings may be used prcnided (1) size is 8 % in. x 11 in-, (2) information in hems 1 through 6 on this report is included on each sheet,(3) cach sheet is numbered and the number of sheets is ri: corded as the top of this form, and (4) emeh sheet is initiated and dated by the Owner of Owner's Desirnee and the A1A.

FORM NIS 2 (back)

9. Remarks: CR.2001-93 reconciles the replacement studs, which were cenified to ASME III 1,1974 Edition, W'74 Addenda and the replacement nut, stich was cenified to ASME 111-1,1980 Edition, %"82 Addenda.

h (Applicable Manufacturer's Data Repons to be attached) CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this replseement conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp: N/A Cenificate of Authq'rization No: N/A Expiration Date: N/A Signed: ) .Supervisine ASME Codes Enrineer Date: 8~!b 19 Oster or Ommer's Designee, Title CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Callfemin. and employed by Arimrfebt Mutual Insurance company (Factory Motaal Enrine-rfor Assylatie) of Norwood, Massachusetts have inspected the components described in this Ommer's Report during the ,v.w M9/SMNlf to M//4/OasiI . and state that to the best :( my knowledge and belief, the Owner has performed exat6inatiobs'a~nd taken correct 6eimeisures described in this Ommer's Repon in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranry, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funbermore, neither the Inspector nor his employer shall be liable In any manner for any penoarl injury or propeny damage or a loss of any L!nd arising from or connected with this inspection. MMt W Commissions / b California

                        )

Inspector's Signature (National Board, State, Prmince, and Endorsements ) i f n G' r Daie1 O h 7 ' h 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A.ae , w byenri we. asurc.d.se m

1. Owner: Southern Califomia Edison Company Unit: 2 r~~N 2244 Walnut Grove Avenue MO: 94090490000
   )                      Rosemead,Califwnia 91770                                                               Rspec GEN-105 R1 P&ID: 40141A F-5
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1201-3
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A
4. Identification ofSystem: Reactor Coolant
                                                                                                                         *          *                   ^
5. (a) Applicable Construction Code: ASME Section III. Class 1.1971 Edition. S'71 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                                                                                             , Rep ued, ,       ASME Name of                     Name Of                       Manufacturer              National               Other              Year
  • Replacedor Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes'No Steam Generator Combustion 71270-2 22219 S2130lME088P 1976 -

Yes Engineering Geared Nut EG&G Sealo!Inc. Heat 52763, N/A RSO 2554-85, N/A Replacement No N93876-0134 SA-194 Gr. 7 Manway Studs (2) Combustion Heat 82158, Ht. N/A RSO 2-P-1131-83, N/A Replacement No Engincedng Code J-6391-1 SA-540 B24 Cl. 3 V I

7. Description of Work: '

The steam generator primary manway stud and nut in location 3 of the cold leg, and stud in location 17 of the hot leg failed their VT-1 examinations and were replaced. "Ihe new replacement studs and nut were VT-1 exammed with satisfactory results.

8. Tests Conducted: System Leakace Pressure Test Pressure: 2258 esia Temp: 510*F m
     -      _ .                       _ .                               _ _ ..,e....                          _ . - t._cd.                         _ . _ _ _, -

M such sheet u awnteed and .w awreber of t'neets a recorded at the k9 et cus fann. and (4) each sheet u estuned and deled by ou Omns er Owner's desgnee and tw AIA

FORM NIS-2 (b:ck)

9. Remarks : None.

e m -.w. w ww. m CERTIFICATE OF COMPl. LANCE We certify that the statements made in the report are coTect and this reolacement conformstothemies of the ASME Code, Section XI. rerair oc replacement Type Code Spnbol Stamp: N/A Certificate ofAuthorizationNo: N/A Expiration Date: N/A Signed: / Sunervisine ASME Codes Eneineer Date: 9 6 Owner or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orPrmince of California. and employed by A rkwrfeht hfutualInsurance Comoanv (Factorv Mutual . ---- Eneincerinr A:sorfstioni gf Norwood. Massachusetts have inspected the components desented in this Outer's Report --- during the period /MM/Q& to M/449E ~

                                                                           . and state that to the best of my knowledge and belief, the Owner has perfonned examinations and faken corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concermng the examinations and corrective measures described in this Owrer's Report. Furthermore, neither the Inspector nor his employer shall be liabic in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                              &                    Commissions Md                               Califomia inspector's Signature /                                    National Board, State Province, and Endorsements Date b]hl~  g.

b., f&Q6 v h

er <

                                                      ~

4 j I

y
                ;(

4

                                                          ' FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPIACEMENTS As a.emand by e.b esi .te.asser c.a. s e m                                                                          .

j i

 ~ ll
  'j l

jl Sheet 1of1 l n

     ' 'A                       1. '       Ownert Soethern California Edimen Cougamy                           .

Unit: ' 2 i

                                                     . 2244 Walmet Game Asemen, n======4 CA 91770                              CWO:         94100582000,94100582001"                                       '

DCP: SG2C8- ']

2. Plant: Sea Ometro Neelaar Generating Staties 'P&ID: 40141A San (1====le, CA 92674 0128 N-5: - 52 1301 -3. Work Performed by: Beebtel Constructies Ceempany Type Code Symbol Stamp:~ IN/Al l' P.O. Der 480 - Authorization No: . ' N/A
                                                                            . Sea Clemente, CA 92674 0128                      Expiration Date                     N/A                                   ,
4. Identification of System: Mels Steams (1301) .
5. (a) icable Construchos Code ASME Section III, Class 1,1971 Edities, S'71 Ahg Code Cases: None - -

(b) Applicable Edition of Secuon XI Utilized for Repairs or Replacements: 1989 Editlen, No Aha

6. Identification of Components Repaired or Replaud and Replacement Components: -

l i ASME

                                                                                                                                                     . - Repaired, Code Name of                   Name of           Manufacturer      National           Other            Year       Replaced, or -       Stamped Component               Manufacturer          Serial No.     . Board No.      Identification       Buat       P-at - t-            Yes/No
                                $21301-ME488                       Combustion Steam Generator                    Engineering    71270-2                22219                                                                                           '
                                                                                                                           . N/A            1976            N/A                 Yes

, Combustion SA-540 Grade B24 .s 1%* Manway Stud Engineering HT #40545 N/A RSO 3522 90 - N/A .- FT-t. No.  ! Combustion SA-193 Grade B7 l 1%* Manway Stud Nut Enginecting HT #J-6765-1 N/A RSO #344045 N/A Replacement ' No i

                                                                                                                                                                                                       ~
7. Desctiption of Work: Removed and reinstalled SX3 secondary manway cover on S2-1301-ME488 with a new stud and nut.

J

8. Tests Conducted: System Leakage [X] System Functional [] Systeminservice [] Hydrostatic [] Pneumatic [} Other[] l Pressurc 983 psig Temp: 544'F Performed on CWO 94090156000.

l

j
                                                                                                                                                                                                         '1 4

a l 1 Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 % in. x 11 in., (2) information . In items I through 6 on this repon is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded _ at the top of this form, and (4) each sheet is initiated and dated by the Owner or Owner's Designee and the A1A l

     , . . . ,                       ..,                .                       -        -                - --                                            ,         . . - -          , - . ~

. _. wer, 7

                                                                                                                                                        ~

FORM NIS-2 (back)

       $           Remsxke None.

(Applicable Manufacturer's Data Reporta to be attached) l h ses04 %el84*ar [ CERTIFICATE OF COMPLIANCE We cenif fthat the statements made in the report are correct and this replaceme,7t_ conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp: N/A CeniGcate of Autwization No: N/A Expiration Date: N/A Signed: t .SupervisingASyE Codes Eneineer Date: I .19h Omter v Oster's Designee,'Iitle ' CERTIFICATE OF INSPECTION I, the undersigned bolding a valid commissio. issued ty the National Board of Boiler and Pressure Vesse! Inspectors and the State or Province of California. and etaployed by Arkwrtrht Mutual Insursoce Company (Factory Mutual Enrineerirar Assoch;ttJon of Kor=voA Massachuset,g have inspecten the components s.acribed in this Owner's Report during the period //)/MW/

     , io S // # 4 4~                       . and state that to the best of my knowledge and belief, the Onser has performed exaufinations a'nd taken corretftive 16easures described in this Owner % Repon in accordance with the requirements of the ASME Code, Section XI.

By shning this ceniGcate, neither t'ae impce 4 nor t.9 ceployer makes any warranty, expressed or implied, conarnin; the ( l cxammations and conective measures described in this O*cer's Repon. Funbermore, neither the Inspector nor his employer shali I be liable in any manner for any personal injury or propeny camage or a loss of any kind arising from or connected with this inspection.

                          .N                 /
                                                  #_                                    Commiss4*ts       /[d-A                       California Inspector's Signature (Wonal Board, State, Province, and Endorsements )

Date I!8A /[ 19(( U' ' 1 4

 ,y FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS                                                                                                    -

um s.dw u w .< asiac ss xx

1. Owner Southern Califamia Edison Company Unit- 2

[] 2244 Walnut Grove Avenue MO: 94100692000 Q R- A, California 91770 Rspec GEN 105 R1 P&ID: 40141A E-5

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5-* S2*1201~3 l l
3. Work Performed by: Southern Califomia Edison Company Type Code SymbolStamp: N/A Authorization No: N/A
                             .                                                                                 ExpirationDate:                    N/A                                         i
4. Identification ofSystem: Reactcr Coolant i 4 .
5. (a) Applicable Construction Code: ASME Section IIL Class 1.1971 Edition. S'71 Addenda. Code Case: None  !
                                                                                                                                                                                             }

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda i

6. Identification of Components Repaired or Replaced and Replacement Components:

Rapered, ASME , Nameof Nameof Manufacturer National Odwr Year Replaced or

  • Code' i c=,- Manufacturer Serial No. Board No. Identifacation Buih Replacement Stamped Ye6'o  ;

Steam Generator Combustion 71270-1 22218 S21301ME089P 1976 - Yes Engmeering Geared Nuts (2) EG&O SealolInc. Heat 52763 N/A RSO 2554-85, N/A Replacement No N93876-0134 SA-194 Gr. 7  ; 0355 r

    /"      Manway Stud                     Combustion                 Heat 82158, Ht.                 N/A      RSO 2-P-ll31-83,              N/A Replacement             No Engineering                Code J-6391-1                            SA-540 B24 Cl. 3                                                             :
7. Description of Work:

The steam generator primary manway stud and out in location 13 of the hot leg, and nut in location 8 of the cold leg, failed their VT 1 examinations and were replaced. The new replacement stud and nuts were VT-1 examined with satisfactory results. , k

8. Tests Conducted: System Irakane Pressure Test Pressure: 2258 esia Temp:ilD*E O _._._ -.,____ _ ..,_.. _ .._,h.__._ _

3)each she. e n.nhered ased e. s mber.(shese a escorded as the sur of du % and @ auch ehen a summand and daisdOwns. tg Owner's demonse and sie A1JL , t

FORM NIS-2 (b:ck)

9. Remarks : None.

m u.-~ ~, m m ,, s. m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstotherules of the ASME Code, Section XI. , repair er reptuemera Type Code SymbolStamp: N/A Certificate of Authorization No: N/A ExpirationDate: N/A Siped; I Supervisine ASME Ccdes Encineer Date: .P 33 Owner or Owner's Desipee, Titic CERTIFICATE OFINSPECTJON I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inrpecton and the State or Province of Ca1Kornia. and employed by bykwricht Mutu al Insurance Companv (Factors kJutual , ,,,__,_ _ Eneineerine Association 1 pf Norwood. Massachusetts have ~ ected the components described in this Owners Report .. during the period fo'2 5 9 / Q 4 to M/4/9 . and state that to the best of my knoviedge and ' belief, the Owner has perform 6d examinations and tiken donective measures desented in this Ow:cers Report in accordance with the requirements of the ASME Ccde, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in tids Ovnets Report. Furthennare, neither the Inspector nor his ernployer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising frem or connected with this * 'on,

                           ~ h nfrpt                  Commissions 1bG                              California Inspedor's Sipature /                                         National Board, State, Province, and Endon unents Date bil,A. . //, f%.-<
                                                                                                                                                                                            -g 7                                                                                                                                                                                  '

. . FORM NIS 2 OWNER'S REPORT FOR REPAIRS GR REPLACEMENTS . - w n a a s, s. p u .e 6. ama c.a. a s ) e... ,

   . . . -                                                      t                                                              Sheat l of 1 '                                                   ,
                      ' 1. '              Ownen Sesehern Calperale Edhna Comepany                         .. ,

Unit: 2-' -! [(FN ti L '[A,#)h Commissions AC.'2 California inspectors Signature (Natior,al Board, State, Province, and Endorsements ) Date 48N k 19b( V 4 d b I e

                                  , FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
                                 ;                           A,a.w.4w w w .ce.Arv.:e.4.s.w n sh.aI ofI
                                                                                                                                                 ~
1. Owner: Southern Califamia Edison Company Unit: 2 2244 Walnut Grovr Avenue MO: 94111649000,001,94110491000
   ,a                              Rosemead,Califomia 91770
   '")             2. Plant:       San Ondre Nuclear Generating Statim FCN: F10539M,F10950M Rspec: 14194 R2,111-94 R1 San Clemente,Califomia 92674-0128                           P&ID: 40141A G-6 N-5: S2-1305-8                               ,,          ..
3. WorkPerfannedby: BechtelConstruction Company P.O. Box 450 TypeCode SymbolStamp: N/A San Clemente, CA 92674 0128 AuthonzationNo: N/A ExpirationDate: N/A
4. IdentificationofSystem Feedwater 4
5. (a) Applicable Cc6struction Code: ASME Section Ill. Class 2.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda. Code Case: N-416-1
6. Identi5 cation of Components Repaired or Replaced and Replacement Components:

r Name of Repaired, ASME Name of Manufacturer Nadenal O'2er Componers Year Replaced er Code Manufaerurer ScialNo. Board No. Identificadon BvDt Reptacernent Stamped Yes/No Pipe Spools Pullman,Inc. N/A N/A S21305ML189 1978 Repaired Yes 2-FW 189-5 2-FW 189-6 18' Sch.100 CS Pipe US SteelGroup Ht CodeRY2125 N/A RSO 1769-94, N/A Replacement No SA 106 Gr. C, (~~T) t CR 2000-94 38' Sch. 80 CS 45 Custom Alloy Trace Code 8985A N/A RSO 1769-94, N/A Repl,acement No Deg. Elbow corp. SA-234 Gr. WPB 18' Sch. 80 CS 90 Custom Alloy Trace Code 8987A N/A

  • Deg. Elbow N/A Replacement No Com. RSog9-94, SA-234 Gr. WP,8,.

CS Gamma Plug WFI,Inc. Ht Code 878WNR N/A RSO 0156-95, N/A Replacement No SA-105, i CR-88-007 R1

7. Description of Work:

The magnetic particle examinations identified cracks in feedwater line S21305ML189 on Unit 2 steam generator S2130lME088 safe-end to 45 deg. cibow (NCR 9312002901). FCN F10539M addresses the removal of a 90 deg. the upstream end Mspool 2 FW-189-5 and spool 2-FW-189-6 and the installation ofnew replacernent material (CW 94111649). Gamma plugs were fabricated and installed following satisfactory radiography performed on the new inst welds (CWO 94110491 for fabrication of gamma plugs). The provisions of Code Case N-4161 were applied which allow for altemative pressure testing. Accordingly, the requirements of the 1992 Edition with no Ad/enda of Sections III and XIwere implemented for NDE and pressu S. Tests Conducted: Sys1em Leakare Pressure Test Pres: 983 t3sie Temp: N/A

    ~

l

   '~~'       "'*

L P*2,'"O:'t.22.l"T"l1:,TOCf. ',.0;t 'lt 2,52:.%t""l'"I'!: o " "::"M*d.'""*

FORM NIS-2 (back) l

9. kemuks: CR SS-007 Rev. I reconciles the plug material,dich was cenified to ASME DL2,1986 Edition,.19S6 Addenda. CR 2000-94 reconciles the replacement pipe, which was ceni5ed to ASME III-2,1986 Edition, No Addenda. .

ve ~mean  ; CERTIFICATE OF COMPLIANCE We certfythat the statements made in the report ne correct and & renair a o d rentseement co:: forms to the rules . . . . of the ASME Code, Section XI. repair =reptue:nent T3pe Code SymbolStamp: N/A Certificate ofAmborizationNo: N/A EgirationDate: N/A Signed:__IM Supervisine ASME Codes Encineer Date: 68 Ownerordwmer'sDesignee Title - # CERTIFICATE OFINSFECTION I, the tmdersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ofCalifornis. and employed by A rimileht Mutual Insu rsnee Comoanv (Factory Mutual EnrIneerine Assoelationi of Norwood. Massachusetts hp e inspected the components described in this Owner's Report during theperiod //&//G S- to (o/9/66 . and state that to the best ofmy knowledge and belief, the Owner has'pe: formed examinations and t'aked cecrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this ceniGeate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective rnessures described in this Owner's Report. Funhermore, neither the Inspector nor his employer shall be liabic in any manner for any personal injury or property damage or a loss of any kind uising from or connected with this

  • ection. .

d A r/ M A >t bommissions /I62 Califemia Inspeidor's Signature / National Bord, State, Province, end Endorsements u 4 u,.. Date Rf & , $6 f/ m O Moi mism

FT . FORM NIS-2A.a.OWNER'S

  • w w 6.i w .re a s mREPORT e.4,s e FOR REPAIRS OR
1. Ovmer: ss .n Southern CalifomiaEdison Compa::y 2244 Walnut Grove Avenue Unit: 2 Rosemead,Califomia 91770 MO: 94111654000, 001,94110658000 FCN: F10540M,F10951M *
2. F1:nt: San Onofre Nuclear Generating Station Rspec: 142 94 R2,11194 R1 San Clemente,Califomia 92674-0128 P&ID: 40141AC-6 N,5: S2-1305-7  ; ..

y 3. WorkPerformedby: BechtelConstruction Company . s P.O. Box 450 San Clemente, CA 92674-0128 Type Code S3r.bolStamp: N/A l Authorizatio:5No:

          '                                                                                                                         N/A Expiration Date:
4. IdentiScation ofSystem: Feedwater N/A
5. (a) Applicable C;onstruction Code: ASME Section IU. Cfass e2.1974 Edit .

(b) Applicable EditJon of Section XI Utilized for Repairs or Replacements: l 1989 Edition. No Addenda. Code Case: N-

6. Identi5cationofComponentsRepairedorReplaced andReplacementComponents:

Name d Name Of Compmera Mamfacturce Repaired. ASME Mandactwer Nc.ienal Cr.her Sch! No. Ycar Reptseed w Code BoardNo. IdemiGcation Buih Repk=

  • Sh~d Pipe Spools Pulhnan,Inc. Yes/No N/A N/A S21305ML190 1978 Repaired Yes 2-FW-190-5 18' Sch.100 CS Pipe US SteelGroup 2-FW-190-6 Ht CodeRY2125 G N/A RSO 1769 94, SA 106 Gr. C, CR-2000-94 N/A Replacement No 18' Sch. E0 CS 45 Custom Alloy Deg. Elbow Trace Code S856A N/A RSO 3347 93, Corp. N/A Replacement No SA 234 Gr. WPB, 1B* Sch. S0 CS 90 Custom Alloy CR4006 93 9 . -

Deg. Elbow corp. Trace Code S987A N/A RSO 1769-94, N/A Replacement No CS Gamma Plug WF1,Inc. SA 234 Gr. WPB Ht Code 878WNR N/A RSO 0156-95, N/A Replacement No SA-105, CR-88-007 R1

7. Description of Work:

A sudace examinstion of the Unit 2 safe end to 45 deg. elbow (steam revealed eracks (NCR 9312003001). FCNF10540M addresses the rem - 2-FW 190-6 and the installation ofnewreplacement material (CWO 941 following successful radiographyperformed on the newinstallation welds (CW gamma plugs). The provisions of Code Case N-416 1 were applied which allow for alte . requirements of the 1992 Edition with no Addenda of Sections III and

8. Tests Comfucted: System Leakere Pressure Test
    ,m""

Pres 984 esie Temp:If%

  \          ]                                                                                                                                           .

x> m g g ,6..w ge g ,., g ,g g g g g.gy . a gggp6x

FO,RM NIS-2 (back)

         ,    o
9. hemarks:

CR-S8-007 Rev.11cemeiles the p ug mzterid, certified to ASME III 2,1986 Edition,19S6 Ad CR 2000-94 reconciles the replacemet pipe, certified to 1986Editie,No Add. CR-2006-93 the 45 deg* cibow, certi5ed to 1989 Edition, No Add. , ,.

                                                                      .,,,,,,,,m._..                                                ,

CERTIFICATEOFCOMPLIANCE We certify 6tt 6e statements made in the report ere ccere:t ed this rensir so d rents ,cete re;<rerreplueiis . , of the ASME Code,SectionXL TypeCodeS)nbolStampi N/A Expirttion Date: N/A Certifeste ofAu6eriutimNo N/A nervisine ASMECodesEncheer Date: d!9.6 Signed:

  • Oumer or 06er'sDesipee, Title CERTIF3CATEOFINSPECTION I, the undersiped holding a vdid co:nznission issued by the Natied Board of Boiler and the State orProsce of California. and employed by A rkwricht hfufus1Iosurance Comnany (Fac En91ncerIne Assoelationi of Norwood, hfassnebusetfs baye inspected the components describe duringthe period ////f/S 6- to_ 4/9/#f , and state that to the best of my knowledge :nd belief, the O*mer has p'erfornied examinstions and tLken corrective measures described in
     '              secordance with the requirements of the ASME Code, Section XI.

By signing this certifieste, neither 6e Inspector nor his empicryer makes eny warret examinatims and corrective measures described in this Outer's Report. Funhennere, neider the employer shall be liabic in sny manner for any persced injury or property damage or a connectedwiththis ' . on. 44# h \ be:nmissions IM Celifemia National Board, State, Province, and Endorsements Inspector's Sipature g.

                                                                                                 &-          , s. -

Date g

                            . M 4,, /99C-4                 v s

3 ! hi I J ... I h.

   ?
   )                                                           .
   .T:

Y;*

     't

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.m wr -we.macoa se sb.m idi

 /

m 1. Owner: Southern California Edison Company Unit 2

      )                           2244 Walnut Grove Avenue                                                                            MO: 94120052000 C/                              Rosemead, California 91770 DCP: 2 2012.00 0
2. Plant San Onofre Nuclear Generating Station W 9 - 012 San Clemente, California 92674-0128 M: 4123B N-5: S2-1208-13
3. WorkPerformedby: BechtelConstmction Company P.O. Box 450 -

San Clemente, CA 92674 0128 Type Code SymbolStamp: N/A AuthorizationNo: N/A

4. Identification of System: Chemical and Volume Control ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section 111. Class 2.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addends
6. Identi5 cation of Components Repaired or Replaced and Replacement Compecents:

Repared. ASME Naais of Name of Manufacnner National 0:ber Year Replaced ~ce code s Component Manufadurar Scrial No. Board No. Identdcation BuDt Replacement Stazaped Ymm l' Relief Valve Crosby N59368-00@03 N/A 2PSV9207 1977 Replaced Yes l' 3000# SW Pipe Camco Ht. Code DAW N/A R:iO 0190-84 N/A Replacement No Cap

   <~3

( ) 7. Description ofWork: The relief valve was permanently removed and spool 2-VC-111 1 A was capped as part of DCP 2-2012.00SN, which modifies the filter housing. A socket-weld pipe esp was installed in accordance with FIDCN M 9816 for ALARA considerations. j i I

8. Tests Conducted: System Functional Pressure Test Pres: 325 psir Temp: N/A
 ;p) o       .

NC7!I: $4591 e.n.m I thefts a d. form ofhstk skanch , er W shey b u d prend.d (1) star is 810 ht a !! WL.o)infarn.mtia. b hans 6.a $m esport a rududed e.. ash ab t. w.-m.h w 6 a ae. >..r.h . - 4.a.e.=,. tee w am sh.h.a.sw.w 44.w6,s.o o n4 eo.Aa.

                  /
     / a'
 ' 9. Remarks : None.

FORM NIS-2 (b:ck) CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Lentseement conforms

                                                               ~

to the rules of tbc ASME Code, Section XL , repairorreplacement; , , Type Code SymbolStamp: N/A Certificate ofAuthorization No: NA ExpirationDate: N/A 4 Signed: . A Stmervisine ASME Codes Engineer Date: /,/S[3'$ Owfer or Ow'mer's Designee, Title CERTIFICATE OFINSPECTION I, the uniersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State x Province of California. and employed by A rknTicht Mutu s1 Insurance Com pany (Factory Mutual En eineerire A ssociationi of Norwood. Mass a ebus etti have insgected the components described in this Outer's Report ciuring theperiod - /~ 6;- Q4~ to 4;//o/G"/, . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and tiken corrective measures described in this Outer's Repert in accordance with the requirements of the ASME Code, Section XL By signing this certiScate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and conective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Ae/4h Commissions /M California Inspector's Signatur/ National Board, State Province, and Endorsements Date __ 1, # h , l995~

             /

4 I 1 l l - e;

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u a.euir.d by a. me--. .re. Asur c.de s-*.au shsse I afi

1. Owner: Southern California Edison Company Unit: 2 (m) 2244 Walnut Grove Avenue MO: 94120187000 V Rosemead, California 91770 .

DCP: 2 2012.00-0

2. Plant: San Onofre Nuclear Generating Station spec: 3 % 2012 San Clemente, California 92674-0128 M: 40123B .

N-5: S2-1208 13

3. WorkPerfannedby: BechtelConstruction Company ,

P.O. Box 450 San Clemente, CA 92674-0128 Type Code Symbo1 Stamp: N/A AuthorizationNo: . N/A

4. Identification of System: Chemical and Volume Control . ExpirationDate: N/A S. (a) Applicable Construction Code: ASME Section IIL Class 2.1971 Edition. S'73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Narna of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Tu don ca Built Replacement Stamped Yes/No 3* Swing Check Walworth-Aloyco A3361 1180 S21208MUO73 1976 See Work Yes Valve Description p 7. Description of Work: He 3' swing check valve was no longer required per DCP 2-2012.00SN, which modifies the filter housmg. Rather than , remove the valve from the systen, only the valve internals were permanently deleted.  ; l i 1 l l

8. Tests Conducted: System Functional Pressure Test Pres: M Isig Temp: E p) i v -

M7TE. ,f al shoem in sw fra ofhaan, nW ar droomse suy be med prostand (t)tiiar is 4 trJ ht u II tit,, o) sJannatan si hans I dwangth 6 as the report b included en each abs

3) and shsee a ownheed and su menbar af shoem a sneerded at eu top elem inna, and (4) nach shes a sutmied and enue be tu owner er Owner's demsnee and aw AR

l . FORM NIS-2 (bsek)

      ' 9. Remarks t None.
                                                       % *-. a. a.,.n.          w .-

CERTIFICA~E OF COMPLIANCE We certify that the statements made in the report are correct and this deletion conforms to the rules of the ASME Code, Section XI. - repairorreplacement Type Code Symbol Stamp: N/A

                                                                                                              ~

Certificate ofAuthorization No: N/A Expiration Date: N/A Signed:- r / Surervisine ASME Codes Eneineer dineirorOster'sDesignee Title Date: (!6!8f

  • CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutumi Insurance Comoanv (Fs etory Mutual Eizrinnrie e Association) of Norm ood. Masssebusetts have inspected the components desented in this Owner's Report during the period. /A 47- W to_ ds//e/96 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken correctis e rocas ves described in this Outer's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neith x the Inspector nor his employer makes any warranty, egad or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuzy or property damaEe or a loss of any kind arising fnxn or connected with this inspection. h Commissions /NC Califomia InspectorsSignature / National Board, State, Province, and Endorsements Date mf [> , /MC

                #          ~ '

i 1 _ a_

1 1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As aw-edbye.rr.e=nonsoreis Aswecod.s- m i sham a of a -

1. Oner: Southern Califomia Edison Company Unit: 2 i (3 2244 Walnut Grove Avenue MO: 94120446001

( ) Rosemead,Califamia 91770 Rspec 042-95 { P&ID: 40141C B-5 l

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5-* S2-1301-2  !

l

3. Work Performed by: Southern California Edison Company Type Code Symbol Stamp: N/A Authonzation No: N/A i Expiration Date: N/A i
4. Identification of System: Main Steam j
5. (a) Applicable Construction Code: ASME Section ZL Class 2.1974 Edition. S*74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs cn Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer Nanonal Othe Yeir . Replaced w *

                                                                                                                                                                             ~

Code' ~ Component Manufacturer Serial ~.4 Board No. Identificadon Built Replacement Stamped Yes/No 3/8" x 3/4 Pipe to Parker Hannifm Heat 39482 N/A 2-ST-002-005, N/A Replacement No Tube Adapter Corp. RSO 1429-93, SA-105

7. Description of V/ork:

r"% ('-) The pipe-to-tube adapter was leaking downstream of S2130lMRI 15 and warranted replacement. Installation and NDE were performed in accordance with weld record WR2-95 164. I

8. Tests Conducted: System Functional Pressure Test Pressure: 863 psia Temp: N%

G NOTL

  • tal shnen e> eu fasia o(hst, maskhan, or drewegs se he used proMed (1) aus a 8 !!2 m a 13 a.C) sdanneman a heres I evmgh 6 on om repon is mduded en each sheet
3) each sheet a membered aM eu murnbe of sheets a rusarded a su tar orthes fann, and (4) ens 6 sheul a subaled and deasd by the Owner or Ommer's desgnse and the A1A

FORM NIS-2 (baek) i

9. Remarks: None.

v -

                                                                  .. a. w.        .r a,.e CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reniseement conformstotherules of the ASME Code, Section XI.                                         repair erretuement                                            i Type Code S   3 mbol Stamp: N/A Certificate of Authorization No: N/A                Expiration Date: N/A Siped:             [                   Sunenisine ASME codes Enginen Owner or Owner's Desipee, Title Date:      J
                                                                                                         /'

96 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht MutualInsuranee Comnanv (Factory Mutual Eneineerine Associationi pf Norwood. Massachusetts have m' spected the components described in this Qwner's Repon during the period 3 /16 /4 S to 7/3//95 , and state that to the best ofmy kn6wledge and belief, the Owner has performed examinations and taken corrective rneasures described in this Owner's Repon in accordance with the requirements of the ASME Code, Section XI. l By siping this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer 4 hall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connect d'with this ' <pection. , Rh . CZ/3f(.n-) Commissions / California [ ' Inspector's Signature National Board, State Province, and Endorsements

                    /

l I l l m huo : 94120446001 l 1 I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

a. a >.d 6, e. p .r6. Assa c.d. =---=
1. Owner: Southern California Edison Company Unit 2 2244 Walnut Grove Avenue MO: 94120695001
  .(~n)                               Rosemead, California 91770                                                                               FCN: F11031M,F11032M Rspec : 145-94 R1
2. Plant San Onofre Nuclear Generating Station San Clemente, California 92674-0128 P&lD: 40134DF 6 N 5: S2-1212-19
3. WorkPerformedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A Authernation No: N/A
4. Identification ofSystem: NuclearPlant Sampling ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 A Admda (Pioinal 1971 Edition. S'73 Addenda. (Valve). Code Cases None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition.No AAAmA=
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaned, ASME Name of NameOf Manufa4mrer National Other Year Replaced or Code Cornpanent Manufacturer Seria! No. Board No. Identificataan Built ' R7'- Stamped

                                                                                                                                                                     .                       Yes/No 3/4' Globe Valve                  Kerotest               VH12-13                                                N/A.      S21212MU008               1978 Permanatly       Yes Deleted 3/4' SW Pipe Cap                  Alloy Stainless       Ht. Code DIA                                            N/A       RSO 0611-95,              N/A Replaccment        No Products                                                                                 SA-182 F316, CR 2000-93
7. Description of Work:

r l Isolation valve S21212MU008 was permanently removed in accordance with FCNs F11031M through F11037M. A socket l weld esp was welded onto the end of the inlet pipe, where the valve was previously attached, using weld s ecord WR2-95 309.

8. Tests Conducted: System FunctionalPirssure Test Pres: >1500 nsir Temp: N/A l
 .O                                                                                                                                                                                                      '
                ---.-,.-~..1,..da..-,._e,d.-.___
3) emit sham h numbused and he number of sheen a seemind at se enp ofIhis fang and (4) ensh abus a suunned and amend by en owns er Owners % and em ADL

FORM NIS-2 (back)

9. Remarks:
                  ~        Tbc replacement pipb cap, cestified to ASME III-2,1989 Editim, No Addenda, was reconciled using CR-2000-93.                         -

e -

                                                                      .ma.upe a m CERTIFICATE OF COMPLIANCE We certdy that the statements made in the repat are correct and this replacement conformstotherules of the ASME Code, Section XI.                                       rep.ir erreptuwmas Type Code SymbolStamp: N/A Certificate ofAuthorizationNo: N/A                   ExpirationDate: N/A Signed:

Owner or Owner's Designee, Title uoervisine ASME Codes Eneineer Date: 7!/E[98 CERTIFICATE OFINSFECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Is.gec- and the State or Province of California. and employed by Arkwricht Mutual Insurance Comnanv (Factorv Mutual Enricttrin e A esociationtof Nopwood. Mas acbusetts have inspected the components described in this Owner's Repat duringthe period _9/R//SE to 7/fM/AM . and state that to the best ofmy knowledge and belief, the Oncr has pefform6d examinations a6d talen corrective measures described in this Oncr's Repat in accordance with the requirements of the ASMB Code, Section XI. By signing this certificate, neither the InWar nor his employer makes any warranty, vg a or implied, concerning the examinations and corrective measures described in this Oner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

  • tien.

sMf1//>f lasp's Signature / Commiedons b California National Board, State, Provmee, and Endorsements Date _21/ A9 lWS

                /      v' b

M M t H1N k W I WM-T-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ua w mye. m re.Asnec s.aw.:e-sh .r a , Unit: 2

           ~
1. Owner: . Southern California Edison Company

, p 2244 Walnut Grove Avenue MO: 94121829000

 -Q                     . Rosemead, California 91770                                        Rspec GEN-122D R1 P&ID: 40112A D-5
2. Plant: San Onofre Nuclear Generating Station N-5-' S2-1204 21 San Clemente, California 92674-0128 ,
3. Work Performed by- Southern California Edison Comp ny Type Code Symbol Stamp: N/A Authonzation No: N/A  ;
                                                                                                   *         *               ^
4. Identification of System: Safety Injection and Shutdown Cooling l S. (a) Applicable Constmction Code: ASME Section III. Class 2.1974 Edition. S*74 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda ,
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer National Other Year Replaced or - Code Cong.onent Manufacturer Seria! No. Board No. Idernification Buih Repla ement Stamped Yes/No 1/2" x 1/2" Relief Crosby N59371-00-0010 N/A 2PSV8154 1978 - Yes 7alve i Spring w/spnng Crosby NX2702-0063, N/A RSO 1539-91 N/A Replacement No ) washers (2) N89058-84-0690,

                                                         -0691                                                                                             i Spindle                     Crosby             K58660-34-0054          N/A       RSO 2-P-294,           N/A Replacement              No          l CR-88-003
7. Description of Work: ,

The relief valve was disassembled for inspection due to leakage. The valve was cleaned and reassembled using a new replacement spring, spindle and spring washers. S. Tests Conducted: System Functional Pressure Test Pressure: RWST @ 96 8% Temp: N_/A wort .. :a e s-. ann,* =* ,. % = y6. . n ie ushs a a n.a.

               - .            .       - ~ .                --d ,==ad m = =av.2 _= = n m.c>.r==.6.,       - . - . e- .p.t. _==h.d.d

FORM NIS-2 (b:ck)

9. Remarks : None.
                        ,                             w-       -

c,a a.r- i.w.=a.e CERTIFICATE OF COMPLIANCE We certfy that the statements made in the report are correct and this replacement confonns to the mles of the ASME Code, Section XI. repair er reptueman Type Code Symbolstamp: N/A Certficate of Authorization No: N/A Expiration Date: N/A b Suoervising ASME Codes Enrineer Signed; Owner or Ow6er's Designee, Title Date: NZ') I CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Comoanv (Factorv Mutual Enrineerine A ssociation) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period ///2s/4 6 to 7/Mf/G6 . and state that to the best ofmy knowledge and belief, the Owner has p6rform'ed examinations and 11 ken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employermakes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this in ction.

  • Commissions /I/$d Califamia Inspector'sSignature / Nationr.1 Board, State, Province, and Endorsements Dat ,

4.3! /3GT f (f% ' - _ a_ , e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A. n d by e r=== <ew AsME Code $womXI sh.n a .(a

1. Oncr: Southern Cahfornia Edison Company Unit: 2 CN 2244 Walnut Grove Avenue MO: 95010620001
     )                       Rosemead,Califomia 91770                                                                 Rspec: EREF-0241 P&ID: 40124B C 2
2. Plant: San Onofre Nuclear Generating Statim N-5-* S2-1208-5 San Clemente, Califcynia 92674 4128
3. Work Performed by: Southern California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A
                            .                                                                                         Expiration Date~-                     N/A
4. Identification of System: Chemical and Volume Control S. (a) Applicable Construction Code: ASME Section m. Class 2.1971 Edition. S*73 Addenda. Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer Natismal Other Year Reptaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 2" Y Type Globe Kerotest MA8-14 N/A S21208MU017 1976 - Yes Valve Disc Kerotest APG6-3 N/A RSO 2552-93 1993 Replacement Yes Cover Kerotest 304239 N/A RSO 2852-93, 1993 Replacement Yes i Part 72609050 O l

  'g/
7. Description of Work:

The valve was disassembled for inspection due to seat leakage. The valve was reassembled after replacing the valve disc, which was worn, and the valve cover, which had been damaged during disassembly. S. Tests Conducted: System Functional Pressure Test Pressure: 2350 nsic Temp: NJ%

  \,

_s _.-_.w.-h._d-_........____,._.h.__._.n_

                                 ^

3)sesh ehem . _ end tw number of shen. .senareed er ou ky ofGun fom and (d)sech sheet a .ubated and dated by em owns or owners daugnee and ou ADL

FORM NIS-2 (becT)

9. Remarks:

The installed valve, as well as the replacement disc and cover, w ere cenified to a higher code class, ASME 111-1, as allowed by ASME 111, paragraph NCA-2134 w , , = - a . % n, a . = ,,a, CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this replacement confonns to the rules of the ASME Code, Section XI. repair er replacement Type Code Symbol Stamp: N/A Cenificate of Authorization No: N/A Expiration Date: N/A Signed: a S Owner et Owners Designee, Title nervisine ASNE Codes Encineer Date: [ CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rk,vricht MutualInsurance Comnanv (Factorv Mutuaj Enfineerine during the period Association)/7/96of 9 to Nora ood. Massachusetts have inspected the components described 7/3//95 . and state that to the best ofmy knowledge and belief, the Owmer has performed examinations and taken corrective measures described in this Chsters Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concern examinations and corrective measures described in this Outers Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or i tion ' connect! th? this in r MUH 0Q A C&ssions lUY Califomia lU'l Lispectors Signature National Board, State, Province, and Endorsements Date [/#/75 1 I i 1 uo: ne a nxn e-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u a mde m.p 4 r .e Asia c.d.s.aw.ca 3has 4 of &

1. Owner: Southern CaliforniaEdison Company Unit: 2
e. 2244 Walnut Grove Avenue MO: 95020158000 R-aA. California 91770

(' }. . Rspec- EREF-0104 P&lD: 40127F C-5

2. Plant: San Onofre Nuclear Generating Station
                                   ' San Clemente, California 92674-0128                                                       N-5: S2-1203-39
3. WorkPerfonnedby: Southern California Edison Company Type Code SymbolStamp: N/A AuthonzationNo: N/A-
4. Identification of System Component Cooling Water
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'74 AAAm4= (BoltinA Code C=aae Nggg (b) Applicable Edition of Section XI Otilized for Repairs or Replacements: ,1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement W-Repaired, ASME Name of Name of Manufacturer National Other Year Replaced or Code Component Manufadurer Serial No. Board No. Built Idsidificatsen Papie stanced F YmNo 10'Bunerfly Valve Fisher Controls BF228813 4065 2HV6216 1978 -

Yes 7/8* 9x10' Studs (12) A&O Engmeenng Ht Code QI N/A RSO 1722-85 N/A Replacement No SA 193 B7 7/8*-9 Heavy Hex A&GEngmeenng H1 Code ADD N/A RSO 1722-85, N/A Replacement No i Nuts (24) SA 194 2H l ( 7. Description of Work: ' 1 The valve was removed due to leakage from the downstream flange. 'Ibe flange boltmg required replacement. The valve was remstalled using the new flange studs and nuts identiSed above. i-

8. Tests Conducted: System Functional Pressure Test Pressure: 80 osig Temp: N/A I

3 ( - wne ,6ei .a. I

                                                .ri % -*                      ,       d -m             h m a a n m.m - *ii i                      =u-s            a e m.m.d.d-3)ensk sheet b aum.bmed and hesusuke elshe.s a seen d.d as as top af an. nom, and(4) and abast a intahsd m.d e.a.d by as owner or oumers d.msnee and 8.e &    a w.              !
   ,: . ~. .
           . n ,. ; . ,   -:. . c.                                                                                            .

FORM NIS-2 (back)

9. Remarks : None.
                                                     ;.,     __.,,.._m,,.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this npf~,;suggt emformstotherules of the ASME Code, Sectim XI. npair er.M Type Code SymbolStamp: N/A Certt6cate ofAuthorizationNo: N/A ExpirationDate: N/A Siped: Own,8/ eror Owner's Designec, Title Smervisine ASME Codes Eneineer Date* ~#//4/95 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State er Province of California. and employed by A rkwrlebt Mutua1 Insurance Comnanv (Factory Mutual Enelneerior Association) of Norwood. Massachusetts h ed the cPJs desenhd in this Owner's Report duringthe period B/P4./G4~ to '//f"8 . and state that to the best ofmy knowledge and belief, the Outer has performed examinations arif taken' corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By siping this certificate, neither the Inspectornor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Outer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this * 'on . d - Commissions /IS2 Califomia Inspector's Sipature ' National Board, State, Province, and Endorsements Date N. A%T

              /      (b e

, .e o e b , 3 =

                             . FORM NIS-2 OWNER'S              REPORT FOR REPAIRS OR REPLACEMENTS u w u m denmac.s, -

m.asas

1. Owner: Southern California Edison Cornpany . Unit: 2 g ~2244 Walnut Grove Avenue MO: 95020801000 i j' R-d. California 91770 Rspec GEN 112R1
2. Plant: P&ID: 40124B E-2 .

San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2 1208 5

3. Work Performed by: . Southern California Edison Company ' Type Code Symbol Stamp: N/A AuthonzationNo: N/A ExpirationDate: N/A
             ~4. Identificatio.n of System: Chemical and Volume Control
5. (a) Applicable Construction Code: ASME Section Ill Class 2.1974 Edition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No AWas
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name of Manufacturer - National Other Year Replaced er Code Compone a Manufacturer SerialNa Board No. Idztification Bulk Replacement Stamped YanSo 1 I/2" x 2' Relief Crosby N59380-00-0002 N/A 2PSV9226 1977 Replaced Yes Valve l I 1/2" x 2' Relief Crosby N59380-00-0008 N/A RebuildMO 1984 Replacement Yes l Valve 94011452

7. Desenption of Work:
                                                                                                                                             ]

The valve in plant position 2PSV9226 was removed due to body-to-bonnet leakage and replaced with a rebuilt spare. The ' removed valve was placed into the rebuild program. l

8. Tests Conducted: System Functional Pressure Test Pressure: 2dOO esic Temp: M l
       " $ % 5 N Ns. k % ". M Ys'm',pt R N $ $E.!, 0 N $s %. Yo.lE U $ $
                                                     .                                                                                1 FORM NIS-2 (b:ck)
9. Remarks : None.
                                                           ; --      ~ ,u. w m CERTIFICATE OF COMPLIANCE We ce:tfy that the statements made in the report are correct and this rentscement conformstotherules of the ASME Code, Section XI.                                         nyaernpw Type Code SymbolStamp: N/A Certificate ofAmborizationNo: N/A                       ExpirationDate: N/A Signed:         /                        Suoervisine ASME Codes Enrineer          Date:        ;rhph5 Owner or Owner's Desigoce, Title CERTIFICATE OFINSPECI1ON I, the smdersigned holding a valid com:nission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State orProvince of Californfa. and employed by A rkwriebt Mutus1 Insurance Comoany (Factorv Mutual EnrIneerine A ssociationi of Norwood. Massschusetts baye in            ed the components described in this Owner's Report during the period . 42//7/Q C                  to 7/'5/49                . and state that to the best ofmy knowledge and belief, the Owner has p6rfom5ed examinations and'take (corrective measures desented in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, erM orimplied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju:y or property damage or a loss of any kind arising from or connected with this inspection.

                      /          A se/Af/71                  Commissions      /N                         Califomia Inspector's' Signature /                                     NationalBoard, State Province,andEndorsements             '

Date . ~4ll/995^

               /       (A      /

i i 1 l 1 l 1 a sg. , ,, # - L.

F l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS un dwe.ri .re.mac.d. - Shast i of &

1. Owner: Southern California Edison Company Unit: 2 p)(
       -                       2244 Walnut Grove Avenue R-4 California 91770 MO: 95020807000 Rspec EREF-0014 P&ID: 40123AB-6
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674 0128 N-5: S2-1201-3 7
3. WorkPerformedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A AuthenzationNo: N/A
4. IdentificationofSystem: Ra n" Coolant
5. (a) Applicable Constmetion Code: ASME Section IIL Class 1.1971 Edition. S'73 Addenda. Code Cases: None s) Applicable Edition of Section XI Utilized fc-Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Nameof M:mfacturer National Other , . Year Replaced or Code s Componset Ma - faa -ur SerialNo. Board No. Identification Built Ecplacemers Stamped YesNo 3/4" Y-type Globe Kerotest TND4 23 N/A S2120lMR074 - Yes Valve Disc BW/IP 64,Part 311023 N/A RSO 1826-94, 1994 Replacement Yes Intemational SA-479 Tp 316 w/ stellite #6 O V 7. Description of Work:  ! I.cakage was observed et the valve and the downstream pipe cap. The valve intemals were inspected and the valve disc was subsequently replaced. The one inch and less exemption was taken for pre =sure testing in accsd nce with ASME XI, IWA-7400. i I l I l

8. Tests Conducted: HgDs Pressure: M Temp: M i

(n)

     '                                                                                                                                                                                      i
         - - .                               _                         _ m...,m.,,m.,_._-,~.e.m.__                                                                                          1
3) each sheet a nuaband end tu number of shes a mounted at se top of aus fann, and (4)sach abe a su.nies and dated W em D=nm er Owneris ds.enne and the AW

K t: ' _

                                                                                                                                  =

a.. . .y n s .

s. s. w a . . .

FORM NIS-2 (b:ck)

        ' 9. Remarks : None.~

w,=.= -

c. o. . = e CERTIFICATE OF COMPLIANCE ,

We certify that the statements made in the report are correct and this replacement conformstotherules of the ASME Code, SectionXI. rep.irerrept eement Type Code SymbolStamp: N/A Certificate ofAuthorizationNo: N/A ExpirationDate: N/A Signed: Owner or OvJfds Designee, Title Suoervisine ASME Codes Nineer Date: (Mid6 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure VesselInspectors and l the State or Provmoe of California. and employed by Arkwricht MutualInsurance Comoanv (Factory Mutual ( Emelmeerine Association 1of Norwood. Massachusetts have inWad he t components described in this Owner's Report duringtheperiod ~E A7/# f to MSMd . and state that to the best ofmy knowledge and belief, the Owner bas p6rformed'exammations and'taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, sg M or implied, concerning the examinations and corrective measures described in this Oner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fem or connected with this ' 'on. [ As h Inspector's'Bignatiire 7 Commissicos /[d2 alifamis National Board, State, Province, and Endorsements K\ -

                                                             \

nate M E /$P6-~

               /                /

l a i

                       .                                                                                                             )

J

o H u FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS un i,y e. hmem a,6e ASME Cae EsaWG

                                                                                                                                                                      . m a ao
l. Owner: Southern California Edison Company Unit: 2
. , _} 2244 Walnut Grove Avenue MO: 95020822000 t
         ,                                          Rot,emead,Califamia 91770                                                                                           Rspec. EREF-0013 P&!D: 40123A F-6
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 N ^<- S2-1208-1
3. Work Performed by: Southem CaliforniaEdison Company Type Code SymbolStamp: N/A Authonzation No: N/A t-
4. Identification of System: Reactor Coolant
                                                                                                                                                                                         *                ^

S. (a) Applicable Constniction Code: ASME Section IIL Class 2.1971 Edition. S'73 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addng!,3 l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of Nam of Manufacti.ver National Other Year Re Code j Cornpment Manufacturer Seria1 No. Board No. Identification Built ' n;placed lassment er starnped Yan/No 3/4" Y-type Globe Kerotest OS22-21 N/A S21208MRI19 1976 - Yes Valve Disc BW/IP Intl. 311023 SN 24 N/A RSO l826-94 1994 Replacement Yes

7. Description of Work:

O The valve was disassembled for inspection due to the accumulation ofboric acid crystals.' He valve was cleaned and reassembled using a new frplacement disc. l l l i 1 I 1 r

8. Tests Conducted: System Functional Praewe Test Pressure: 31QP;ig Temp: N_/A

)

                                 ~.  . _ , -._a..,-._                                                           ., _ .          . _,. , ,__ m _. . m .,,

m.,._a _. .~ _._.,._ _ .. __ . . I

FORM NIS-2 (b:ck)

9. Remarks :

The replacement disc was cenified to a higher code class, AShE III-1, as allowed by AShE III, paragraph NCA 2134 v w - - ~ m ,:,. m . m .,a.u.a, CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this renlacement conformstotherules of the AShE Code, Section XI. repair er rephament Type Code S 3 mbol stamp: N/A Cenificate ofAuthorization No: N/A Expiration Date: N/A Siped: I # Sunervisine ASME Codes Eneineer Owner or Owners Desipee, Title Date: [ //f5 CERTIFICATE OFINSPECTION I, the undersiped holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comoanv (Factorv Mutual Eneineerine Associationi of Norn ood. Maisachusetts have inspected the components described in this Owners Repon during the period .3h3/95 to 7/3//M . and state that to the best of my knowledge and belief, the Ouner has perfonned examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the AShE Code, Section XI. By siping this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connect dwiththisinspecti M h [ Commissions /WCalifornia Inspectors Sipature National Board, State. Province, and Endorsements Date I/#/iI Mo: 8502%m

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.a. ,sede e. ram r .re.Asurc.d.sa ann  ; m i .e i

l. Owner: Southem CaliforniaEdison Company Unit: 2 2244 Walnut Grove Avenue MO: 95020881000 95020882000 Rosemead, California 91770.

Rspec 027-95,EREF-0250

2. Plant: San Onofre Nuclear Generstmg Station PAID: 40123A E-7 ,

N-5: S2 1201-3-9 SanClementes California 92674 0128

3. WorkPerfonnedby: Southern California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A.

Expiration Date: N/A I

4. Identification of System: Reactor Coolant l

S. (a) Applicable Construction Code: ASME Section IIL Class 1.1971 Edition. S'73 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Adaman

6. Identification of Components Repaired or Replaced and Replacement Components:

Repured, ASME ~ Name of Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacsonant Stamped YesHe 2" Y-type Check Kerotest ABR9-17 N/A S2120lMUO21 1983 Repaired Yes  ; Valve Disc Kerotest AKF21 N/A RSO 5866-85 1985 Replacement I Yes Cover Kerotest AMM2-2 N/A RSO 0437-86 1985 Replacement Yes 4 [

7. Description of Work -

The check valve failed functional testing as skscribed in NCR 95020024. The valve was disassembled for rework and reassembled using a new replacemeat disc and cover under MO 95020882. The body-to-cover fillet weld was perfonned in accordance with weld record WR2 SS 131 and MO 95020881. A PT examination oc performed on the completed weld. l

                                                                                                                                                                              )
8. Tests Conducted: System Leaksee Pressure Test Pressure: 2255 osia Temp: 510*F O _ _ _ __ _ _.._.... _ ._ ._ohd
3) each shes e awnbered and 8. nsnbe of shoem a recorded at ow enp of the imm, and M)each sheet u .etaled and dated by the Owns or Owners dessener and the AIA.

r+

FORM NIS-2 (b:ck)

9. Remarks : None.

ww - _ , we m CERTIF]CATE OF COMPLIANCE We certify that the staternents made in the report are co: rect and this rentseement conformstotherules of the ASME Code, Section XI. nper or npluement Type Code Spnbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A Siped:,_ / M Xervisine ASME Codes Engineer Date: [ 95 r#ner or Owner's Designee, Title { CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by A rkwricht Mutua1 Insurance Comoanv (Factorv Mutual - Eneincerinr Association) of Norwood. Massachusrttspave inspected the components described in this Owner's Report during the period M//6/96 to 9/R/M . and state that to the best of my knowledge and belief, the Owmer has per' formed examinations and iaken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this * 'on. [ e#Af3dSR Commissions NO Califomia Inspector's Sipature / National Board, State, Prosince, and Endorsements Date k/JO, W fQ9[

                   /

l 1 i Mo: 95020ea1oco

r FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ' as m d krs.r .rer ASME dads e -=====vt ama a et 4

1. Owner: Southem Califomia Edison Company - Unit: 2 <

q 2244 Walnut Grove Avenue Rosemead,Califomia 91770 MO: 95021078000 l Rspec: 029-95 P&ID: 40130B B-7

2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1201-13
3. WorkPerformedby: Southem California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A i
4. Identification of System: Reactor Coolant
5. (a) Applicable Construction Code: ASME Section IIL Class 2.1974 Edition. S*74 A Adada (Tubinei S'75 A AAMa (Valvel  :

Code Cases None * (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No A AAm.& i l

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer National Other Year Replaced or Code Component Manufneturer Serial No. Board No. Identi6 cation Built Replacement Sumped Yes'No c37.s' 3-Valve Bypass Gould Inc. 15128 N/A Upstream of 1978 Replaced Yes gdanifold 2PDT0123 3/8* 3 Valve Bypass Gould,Inc. 15041 N/A RSO 2073-84 1978 Replacement Yes Manifold 3/8" OD Tubing Sandvik Heat 703114 N/A RSO 0488 95, N/A Replacement No SA 213 TP316

7. Description of Work:

The 3 valve b3pass manifold upstream ofinstrument 2PDT0123 was replaced as a result of seat leakage. The instmment tubing also required replacement due to the accumulation of boric acid crystals on the tubing. The existing pipe-to-tube . adapter fittings were reused.

8. Tests Conducted: System Functional Pressure Test Pressure: 2262 nsic Temp: N/A Nort ,, J sheets a tu form of hsts, skaiches. er drawegs may be med promhed (I) sue b 8 I4 m a Il 4% Q)' m hems 1 Ormsb 6 on om supon a actuded on och sheet, 3)each shest e awnbered and tu numbs of sheen is smearded a de top ofihm form.and (4) anch shest e outsled and dated by Sir Owner er Owners desgnse and the AIA.

FORM NIS-2 (b:ck)

9. Remarks: None.
                                                +nu.m u.,mmm.um us a s. a.a.a, CERTIFICATE OF COMPLIANCE                                                   <

We cenify that the statements made in the report are correct and this reofacement confonns to the mies of the ASME Code, Section XI. repair or reptuement Type Code Spnbol Stamp: N/A Cenificate ofAuthorization No: N/A Expiration Date: N/A Signed: - Sunervidne ASME Codes Encineer Date: 8 MI Owner or Owner's Designee. Title CERTIFICATE OF INSPECTION 1, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsuranee Co nnanv (Factorv Mutual Encineerine Association) of b'ornod. Maisachusetts have inspected the components described in this Owner's Repon during the period J// 2 / 95 to 7/3//95 . and state that to the best of my knowledge and belief, the Owner has perfonned examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,'Section XI. By signing this cenificate, neither the Inspector nor his employer makes any wananty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Repon. Funhermore, neither the Inspector nor his employer rhall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connect with thisin tiort. biolltvl . Inspector's Signature aa fun Commissions N$ California b NationalBoard, State Province,andEndorse sts Q Date $/l $5

.= a o

m / FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.am .r 4:use.d.s.es m shmal er,

1. Owner: Southern California Edison Company - Unit: 2
  '[ )                      2244 Walnut Grove Avenue                                                                                         MO:        95021158000 U/                       Rosemead, California 91770 Rspec: 030-95 P&ID: 40134A E-5
2. Plant: San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1212-13
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A
       ' 4. Identi5 cation of System: NuclearPlant Sampling                                                                                Authonzation No:                       N/A ExpirationDate:                        N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 A ANs Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer Nationat other Year Replaced or Code Camponent Manufacturer Serial No. Board Net IM- Built Replaame===r Stamped Yes/No Mechanical Snubber Pacific Scientific 13958 N/A S2SS037H006 1980 - No PSA 1-4 3/8"Imad Pin Paci5c Scientine Heat N2959 N/A RSO 2657-90, N/A Replacement No SA-564 Gr. 630 O 7 . DescriptionofWork: d The snubber load stud was replaced with a load pin for casier access and ALARA considerations. A VT-3 exammation of the support assembly was performed aner installation.

8. Tests Conducted: MS Pressure: E!A Temp: N!A

_ s___.___.--__.._....__.,_,._.__ 3)each sheit is nurnbered and tu asuber of sheets a ses.rded at On lor of Gus fanut,and (4)each ohna is tenmind and essed by On Ouma er Ownes daigne, and the A1A

FORM NIS-2 (b:ck)  !

9. Remarks: None.  !

w -, a. a,, a m j CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstothe mles of the ASME Code, Section XI. repair orreplacement Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A Expiration Date: N/A 2!9T Signed: / Sucervisine ASME Codes Ennneer Date: Owner or Owher's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Companv (Factory Mutual EnrIneerine Association) gf Norwood. Mass schusetts have inspected the components desenkd in this Owner's Report during the period

           ,.2/f27/M 5'             to     6/(/4C . and state that to the best ofmy knowledge and belief, the Owner has perfdmed c'xaminations and taken ' corrective measures desenhd in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures desenkd in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or pmperty damage or a loss of any kind arising from or connected with this mspection. Jf)#3d/77 ' Commissions /bj Califomia Inspector's Signatyfe National Board, State, Prosince, and Endorsements ou Gh1L4.1%T l/ 4 Mo: 95C211$5000

FORM NIS-2 GWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 4.n.gd d by6.n efn Asia c.d -vi EbsstI ef t 1.' Owner: Southern Califernia Edison Company Unit: 2 2244 Walnut Grove Avenue MO: 95021160000 '

 -(m[

kJ R-=A. California 91770 Rspec 031-95 3

2. Plant- San Onofre Nuclear Generating Station -
                                                                                                                        . P&ID: 40141A San Clemente, California 92674 0128                                                           N-5-*      S2 1301-2
3. WorkPerformedby: ' Southern California Edison Company Type Code SymbolStamp: N/A
4. Identification ofSystem: Main Steam No: A De, l

S. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition. S'74 A AA ada Code Case None - ' (b) Applicable Edition of Section XI Utilized for Repairs or Repleennents: 1989 Mition. No AdMa  !

6. ' Identification of Components Repaired or Replaced and Replacement Components:  !

Reposed, ASME Name of Nameof Manufacturer Nationat Other Year Replaced or Code C- Manufacturer Serial No, Board No. Idenuficaban Built R7 Br===rari 5 Yes/No f MechanicalSnebber Pacific Scientific 5954 N/A S2ST018H041 1978 - Yes PSA 1/4 - 4 i 3/8" Lond Pin Pacific Scientific N2959 N/A RSO 2657-90 N/A Replacesnent No

7. Description ofWork:

O The snubber load stud was replaced with a load pin fcr easier access and ALARA considerations. A VT-3 exammation of the V support assembly was perfanned after installation.

                                                                       \

k

                                                                                                                                                                                   ~

I l l l l l l 1 l

                                                                                                                                                                                      \
8. Tests Conducted: Fl% Pressure: U!% Temp: H/A

(^) .

  \    Nom      *c'        "
                          . shsam m te form ofhsen, A% er drawings mey be innd gemded (1)sur s 8 I/J h a la h. Q)mfh si teurus I eragh 6 en Sus esport a insinded on ensb short, i '
3) sun sheet is numbaud and tw msnbe of abeas b immerded at se tap of $m face, and (4)ensk abest is suunned and dated by em Ourner er Onnart daugnar and te AIA,

[ . 1 FORM NIS-2 (b::ck) l

9. Remarks : Neoe. . 1 u._ . o upon. . m CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement confonnstothe rules l of the AShE Code, Section XI, repair orreplacement Type Code SymbolStamp: N/A Certificate ofAuthorizationNo: N/A Expiration Date: N/A Signed: -

Oumer or Owner's Designee, Title Supewisire ASME codes Encineer Date: I !95

 .                                                         CERTIFICATE OFINSPECTION T, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnanv (Factory Mutual Encineerine Associatlan) of Norwood. Mass schusettspave inspected the components desenkd in this Owner's Report during the period 4dM4796 to                  6/#/G6                 . and state that to the best of my knowledge and belief, the Owner has performed exafninations and taken (orrective measures desenkd in this Owner's Report in accordance with the requirements of ie AShE Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this nspection.

                                &#fM./ Commissions                                  /Idj                       Califomia Inspector's signature /                                         National Board, State, Province, and Endorsements Os,e m a e r
                     /7-e 0

ho: 95c211eccoo

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS A.a m e.t.+.os.es.Asurc.d.s e Shamleft

1. Owner: Southern California Edison Company Unit: 2
 '(                                                         2244 Walnut Grove Avenue MO: 95021212000 s                                                        Rosemead, Califami 91770                                                                                                    Rspec 060-95 P&ID: 40130A
2. Plant: San Onofre Nuclear Generating Station San Clemente, Califamia 92674-0128 N-5: S2-1201-6
3. WorkPerfonnedby: Southern California Edison Company Tm Ne SW Sup N/A
4. IdentificationofSystem: ReactorCoolant A D

i l 5. (a) Applicable ConstructionCode: ASME Section IIL Class 2-NF.1974 FAition. S'74 Addenda. Code Case: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: j989 Edition.No Addenda f i

6. Identification of Components Repaired or Replaced and Replacement Compecents:

Repared, ASME Name of Name of Manufacturer National Other Year Replaced er Code r- Manufacturer Serial No. Board No. Identification Built R;1 ~ nent Staoiped Yes/No MechanicalSnubber Pacific Scientific ~;i;54 N/A S2RC149H00C 1986 - No PSA 1/4 - 4 3/8" lead Pin Pacific Sciriific N2959 N/A RSO 2657-90, N/A Replacement No SA 564 Gr. 630

7. Description of Work-The snubber load stud was replaced with a load pin for easier access and ALAPA considerations. A VT-3 exammation of the support assembly was performed after installation.

A e

8. Tests Conducted
NL% Pressure: N]% Temp: N]%

i i == .. w.h .a .rm- a y h. d ,, d.d o> . in a u 5a> wo, --i w d o. n.m -

3) each sh.st is membend and tu munbe of shes. m noorded at tw top of tus Tann, and (4) each shes a henbd and dansd h du owner or 06 deugner and in A1A, i

I

FORM NIS-2 (b:ck)

9. Remarks : None.

en .o m.p , w e CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonnstothe rules of the ASME Code, Section XI. repair orreplacement j Type Code SymbolStamp: N/A Certificate of Authanzation No: N/A ExpirationDate: N/A Signed: / / Surervisine ASME Codes Encineer Date: f 9J Owher or Ow*ner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwriebt Mutual Insurance Comnanv (Factory Mutual Enrineerine l As sociation) of Norwood. Mas:acbusetts have inspected the components described in this Owner's Repon during the period

V/:V96 to M/#/QT . and state that to the best of my knowledge and belief, the Owner has -

perfolmed exammations and taken (:orrective measures desenkd in this Outer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall l be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this  ; tnspection. i

                           /d#f40d#h             '

Commissions $d Califamia Ins;Ector's $ignature/ National Board, State, Prmince, and Endorsements I ou 0 % 4,1975 rr  : Wo: 95021212000

b FORM NIS-2 OWNER'S u n, REPORT FOR REPAIRS OR REPLACEMENTS a ny e. %w we. Ashe ce sanoOO Sheet I of 3

1. Owner: Southem Califomia Edison Company Urdt: 2 2244 Walnut Grove Avenue MO: _95021213000

( Rosemead,Califomia 91770 Rspec 041 95 P&ID: 40113B

2. Plant: San Onofre Nuclear Generating Station San Clemente, Califomia 92674-0128 N-5' S2-1204-9
3. WorkPerformedby: Southem Califomia Edison Company Type Code S3 mbol Stamp: N/A
4. Identification of System: SafetyInjection and Shutdown Coolm.g - Authorization No: N/A Expiration Date: N/A
5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition S'74 Addenda Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Re. Mired, ASME Namrof Name Of Manufacturer National Other Year Replaced er Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 38687 N/A S2S1074H002 1992 - No PSA 1/4 -4 Load Pin Pacific Scientific Ht.N2959 N/A RSO 2657 90 N/A Replacement No SA-564 Tp 630

7. Description of Work:

The snubber load pin was replaced. A VT-3 examination of the support assembly was performed after installation.

8. Tests Conducted: He Pres: H% Temp: H%

M i. U O e. D O.m " D 7m Y. .r N D $ $ U O ". M U de *.od . Yo M E A N '" 9

FORM NIS-2 (b:ck)  ; l

9. Remarks: None. , I e:

wm ua,,uua u,um a,a,,a, CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conformstothe rules ' af the ASME Code, Section XI. repair or replacement l Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: Supervisine AShE Codes Enrinen Date: Y/I Owner o/ Owner's Desismee. Title CERTIFICATE OFINSPECTION , I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comoanv (Factory Mutual Enrince rine Association) of Norwood. Massachusetts have inspected the components described in this Owner's Report during the period 2/27/95 to S/22/95 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective Incasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injmy or property damage or a loss of any kind arising from or connected with this inspection. ; r a 'Ct. CL1bn Commissions Califomia 674 Inspector's Signature National Board, State, Province, and Endorsements Date  ! MO: 95021213000

q FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

                                                           .           use,u er .erise a.or m ecea, -

Best I af a  !

1. Owner: Southern CaliforniaEdian Company ' Unit: 2

.(,,j 2244 Walnut Grove Avenue MO: 95021216000,95031256000 (,/ Rosemead, California 91770 Rspec 069-95 P&ID: 40111B l

2. Plant- San Onofre Nuclear Generating Station San Clemente, California 92674-0128 N-5: S2-1212-6  !

1

3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A AuthorizationNo: N/A Expiration Date: N/A >
4. Identification of System: Nuclear Plant Sampling , i
5. (a) Applicable Construction Code: ASME Section IIL Class 2-NF.1974 Edition. S'74 AdAmda Code Cases 1644-7 (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repas4 ASME Narne of NameOf Manufacturer National Other Year Reptaced or Code e v Manufacturer SerialNo. Board No. Identification Built Replacement Sumnped Yes/No  ; MechanicalSnubber PaciSc Scientific 37421 N/A PSA.1/4 - 4 S2SSO42H010 1986 - No ) 3/8%ad Pin Pacific Scientific N2959 N/A RSO 2657-90, N/A Replacement No , SA 564 Gr.630 Mechanical Snubber Pacific Scientific 37422 N/A S2SS042H021 1986 Replaced No  ; PSA 1/4 - 4  ! [V] Mechanical Snubber Pacific Scientific 38708 N/A RSO 1081-92 N/A Replacement No  ! PSA 1/4 - 4 3/8%ad Pin Paci5c Scientific N2959 N/A RSO 2657-90, N/A Replacement No SA 564 Gr. 630 i

7. Description ofWork-
                                                                                                                                                                                           )

i The snubber load studs were replaced with load pins for easier access and ALARA considerations under MO 95021216.  ; Subsequently, MO 95031256 replaced mechanical snubber S2SSO42H021 as a preventative maintenance action. The  ; snubber assemblies were visually examined (VT 3) with satisfactcsy results. The removed snubber was placed into the snubber rebuild program. l l I l I 1 l l

8. Tests Conducted:N/A Pressure: E Temp: E l l

4 l

%                                                                                                                                                                                           l Norr suppasmeier shoem ei en seem of hee, skashes, er es. sos swy be seed prended 0)== s in s 1 m., c) krenneman nn liens a nuouch e en om repan a induisd en each sheet, i

3)each does s - _ and the number of thesis a recorded a Su anp of om ferg and (4)each ehen k sateled and dined by the Owner er Oumer's emagnes and tw AIA,

[ , FORM NIS-2 (bcck)

9. Remarks : The replacement snubber was certi5ed to ASME III 1 NF as allowed by ASME III, paragraph NCA-2134.

6Apphanus Me,mbaarurs pum Reports e, si W CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstothe rules of the ASME Code, Section XI. - repair orreplacement Type Code SymbolStamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Signed: Owner or Owner's Designee, Title Sunenisine ASME Codes Encinen Date: t/#/95 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwriebt MutualInsurance Comnanv (Factory Mutual Encineerinr Association) S#f/6/C of Norwood. to 4:e/9'/ Massnebusetts d> . and b@state ave in5seted the components described in this Owner's Rep that to the best ofmy knowledge and belief, the Owner has  ; perfortned examinations and taken'cortc6tive measures described in this Owner's Report in accordance with the requirements of i 6e ASME Code, Section XI.  ; By signing this certificate, neither the Inspector nor his employt:r makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owacr's Report. Furthermore, neither the Inspector nor his employer shall l be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this  ! mspection. 4h Commissions / b '2. California l Inspecior's Signature / National Board, State, Prmince, and Endorsements i i b oate y AL9,. /9?C 1

t i

                          ' FORM NIS-2 OWNER'S REPORT FOR' REPAIRS OR REPLACEMENTS un           nrasn            .ee. Anac.d.s =xx Sheeti ett                                         f
1. Owner: Smthern CalifamiaEdison Cornpany Unit- 2 '

O 2244 Walnut Grove Avenue MO: 95021301000 -V F- A. California 91770 Rspec. 034-95 P&ID: 40111C

2. Plant: San Onofre Nuclear Generating Station N-5: S2-1212 9 San Clemente, California 92674-0128
3. WorkPerformedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A
4. Identification ofSystem: NuclearPlant Sampling Authorization No: N/A ExpirationDate: N/A S. (a) ApplicableConstructionCode: ASME Section III. Class 2-NF.1974 Edition. S'74 AAAanda Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda 6, Identification of Components Repaired or Replaced and Replacement Components:  !

Repared, ASME Name of Name of Manufacturer National Other Year Replaced or Code Component Manufacnner Seria!No. Board No. Ideaufiataan Buik R7'-

                                                                                                                                                                      - ^

stamped Yes/No i 1 MechanicalSnubber Pacific Scientific 4797 N/A S2SS072H00Y 1978 Replaced Yes PSA l/4 - 4 Mechanical Snubber Pacific Scientific 38644 N/A RSO 2181-91, N/A Replacement No PSA 1/4 -4 CCase 1644-7

                                                                                                                                                                                         )
7. Description ofWork:

d ' The mechanical snubber was replaced as a preventative maintenance action. The snubber assembly was visually av==inad (VT-3) after installation with satisfactory results. The removed snubber was placed into the snubber rebuild program. i

8. Tests Conducted: h11.A Pressure: M Temp: M I O

V ,crs: _  :.i.e%.r m . . d m a.m.nm.o3 .-iu.. t.au.-a= 1 3)ench sheet a numbered and en numbs of shes. m .conded at es k9 ersus fara and (4) ansa sheet a sumaled and doesd by em 0,me er Demer4 demense and em AR

i FORM NIS-2 (b:ck) l

9. Remarks : The replacement snubber was certified to ASME III-1-NF as allowed by ASME III, paragraph NCA-2134.

we --

                                                                         .a. wha e CERTIFICATE OF COMPLIANCE We certfy that the statements made in the report are correct and this renlacement          conforms to the rules                      l of the ASME Code, Section XL                                      repairorreplacement Type Code SymbolStamp: N/A Certficate ofAuthonzation No: N/A                        ExpirationDate: N/A Signed:      // d                                Suoervisior ASME Codes Encineer                Date:       I       .9J Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure VesselImpectors and the State orProvince of California. and employed by A rkwriebt MutualInsurance Comnanv (Factory Mutual Enelacerine Anociatien) of Norwood.

f Massaebusetts have inspected the components desented in this Owner's Report during the period

               #d#7/M               to 5744/4?f                  . and state that to the best of my knowledge and belief, the Owner has perfor6ed c'xaminations and takefi corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, up M or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthennere, neither the Inspector nor his employer shall > be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

       $8Pection.

df/h_ Commissions /M2 California Inspector's Signature / National Board, State. Presince, and Endci-G

                                                           ,i Date       8$Mi/N6
                    //\

v. l l l l l Mo: ese21Xn000 l

( 9 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS -  ; A.a dsyn.7, -.s. ors = Asurc.d.s.a=x ' shun a ao

1. Owner: Southern California Edison Company ~

Unit: 2

      ;(/'y 2244 Walnut Grove Avenue Rw=A. California 91770 MO: 95021302000 Rspec 035 95                                                                    ,

P&ID: 40141A I

              . 2. Plant-           San Onofre Nuclear Generatirg Station N        S2-1301-1 San Clemente, California 92674-0128                                                              '                                                                         ,
3. WorkPerfonnedby: Southen California Edison Company Type Code Symbol Stamp: N/A ,

Authartzation No: N/A. l

4. Identification ofSystem: Main Steam
5. (a) Applicable Construction Code: ASME Section HL Class 2-NF.1974 Edition. S'74 AdAmla cme Cases 1644-7
      ,             (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufactum National Other Year Replaced or Code Component Manufactwar SerialNo. Board No. Idenhfication Built Replacement Stamped Yes/No Mechanical Snubber Pacific ScientiSc 3316 N/A S2ST014H041 1977 Replaud Yes . PSA 1/4 - 4 Mechanical Snubber Pacific Scienti5c 38710 N/A RSO 1081-92 N/A Replacement No PSA 1/4 - 4 r ( 7. Description of Work: , The mechanical snubber was replaced as a preventative maintenance action. The snubber assembly was visually examined (VT-3) after installation with sitisfactory results. The remoad snubber was placed into the snubber rebuild program. l l i

8. Tests conducted: NE Pressure: H% Temp: U!%  !

l I _ _ . - . - _ .._ _d._ d. _ ..,_ .... _ _ _ , .. e. _ _. _ . F1 s.ch sheel b awnband and Ow su her of sh.m . seeerd.d at On top of Gu. % and (4) mch shest h butaled and doesd by se oumer er Damers daugn.e .nd De A1A

y- - FORM NIS-2 (back)

9. Remarks : The replacement snubber was certified to ASME III-I-NF as allowed by ASME III, paragraph NCA-2134.

e..

                                         ,                     -. um m,              %

CERTIFICA1E OF COMPLIANCE

  ~

We certify that the statements made in the report are correct and this replacement conformstothe rules of the ASME Code, Section XI. - repair or replacement Type Code SymbolStamp: N/A Certi5cate ofAuthorizationNo: N/A Expiration Date: N/A Signed: Owner or Owner's Designee, Title Supervisine ASME Codes Enemeer Date: 4 h/95 ' CERTIFICATE OFINSPECTION . I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure VesselInspectors and the State or Provmee of California. and employed by Arkwriebt Mutual Insurance Comoanv (Factory M'utual Enrineerine Association) of Norwood. Mass a ebusetta havye 'ed the components described in this Owner's Report during the period 8//#7C to 6 /49 / 9 5 . and state that to the best of my knowledge and belief, the Owner has pcfofmed examinations and taken'cofrfetive measures described in this Owner's Report in accordance with the requirements of the ASME Code, SectionXI. By signing this certificate, neither the Inspector nor his employer makes any warranty, sp M or implied, concernmg the examinations and corrective measures desenkd in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspection.

                      //           A 4e2&A              ~ Commissions ' 84 %                                California Inspect 07s Sigriature    /                                   National Board, State, Province, and Endorsements             3
                                                            ~.
                                                            \'

D*tc 0, /995~

                /

l l Mo: 950lMs02000 1

i I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. m.g-d w s= Puumme das ASME Cons mm 3hast i of 4 j
1. Owner- Southern CaliforniaEditon Company Unit: 2  ;

7 m., 2244 Walnut Grove Avenue MO: .95021465000 ' '. ) R-ad. California 91770 Rspec: 033-95

2. Plant: San Onofre Nuclear Generating Station P&ID: 40113B N 5'- S2-1204-2 j SanClementes California 92674-0128
                                                                                                                                                                         )
3. WorkPerfonnedby: Southem California Edison Company Type Code SymbolStamp: N/A Authonzation No: N/A  !
                                                                                                             *          *               ^
4. Identification of System: SafetyInjection and Shutdon Cooling
5. (a) Applicable Construction Code: ASME Section m. Class 1-NF.1974 Edjijon. S'74 Addwfa. Code Case: 1644-7  :

(b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No AdAmAn

6. Identification of Components R'epaired or Replaced and Replacement Components:  :

Name of Repastd, ASME Nanu Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. N' Idanification Buik - Stamped l Yes/No  ; Mechanical Snubber Pacific Scientific 38649 N/A S2SIO66H030 1991 Replaced No l PSA 1/4 - 4 Mechanical Snubber - Pacific Scientific 38705 N/A RSO 1081-92 N/A Pqlacement No PSA 1/4 - 4 i

7. Description of Work:

The rnechanical snubber was replaced as a preventative maintenance action. The snubber assembly was visually exammed (VT 3) after installation with satisfactmy results. The removed snubber was placed into the snubber rebuild program.

8. Tests Conducted: N% Pressure:N!% Temp: N!%

O _ . . _ ._ . _. ._ _ . . _ . . , __ _ d _ . _. _ 3)auch shest a nwnhand ard ou number of shout is semaided et tw top of tus fann, and (4)each ohnet is outened and esand h tu Dwner as Owners desgner ved om A

FORM NIS-2 (b:ck)

   - 6. Remarks : None.
                                        .             - u-. o. a,                 -

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this umlacement conformstothe rules of the ASME Code, Section XI. repairorreplacement Type Code SymbolStamp: N/A , Certtficate ofAuthorizationNo: N/A ExpirationDate: N/A Signed: M Supervisine ASME Codes Eneineer Date: /JM/97 Owner or Owder's_ Designee, Title CERTIFICATE OFINSPECTION r, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Companv (Factory Mutual Enrineerine l As soelatJon) of Norwood. Massaebusetts h3ve inspected the components described in this Owner's Report during the period

         #/J7/#C                  to      (p/9/Vf . and state that to the best ofmy knowledge and belief, the Owner has perfd'rmed 'c:caminations and taken' corrective measures described in this Oumer's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concernmg the examinations and corrective measures described in this Owner's Report. Ftuthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.

                             /A#h CommissionsNational                      M2 Board, State, Province,Califenia Inspe'ctorssigniture /                                                                        and Endorsanents               l l

Oate, ,! - e O

[' L FORM NIS-2 OWNER'.S REPORT

4. #.,iymmor FOR REPAIRS OR REPLACEMENTS ASECatsSunoni7, m i.o
1. Owner: Southern CaliforniaEdison Company Unit: 2

(( 2244 Walnut On>ve Avenue ' MO: 95021485000. Aj R-=A California 91770 Rspec: GEN 140 . P&ID: 40lllB

                . 2. Plant:           San Onofre Nuclear Generating Station N-5:       S2-1201-2 San Clemente, California 92674-0128
3. ' Work Performed by: Southern California Edison Company Type Code Sytnbol Stamp: N/A Au-u uuu No: N/A
4. Identification of System: Reactor Coolant '

S. (a) Applicable Construction Code: ASME Section IIL Class I.1971 Edition. S'71 Addada Code Case None

                     ' (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addeda
6. Identification of Components Repaired or Replaced and Replacement Components: '

Repaired, ASME Name of Name of Manufacturer National Orer YeEr r Replaced or

  • Code- '-
                                                                                                                                                                                                        - e
                             '"P                          Manufacturer                  Serial No.             Board ha.           Identification          Built     Replacement         Stamped YesWo Pressunzer                        Combustion                  70602                           21495        S21201ME087                  1976            -               Yes Engineering 1 1/2" x 141/4'                   Combustion                  Ht Code J-6391-1,                N/A         R50 2-P-ll31 83,             N/A Replacement                 No Manway Studs                      Engmeermg                   Heat /82158                                  SA-540 B24 Cls 3 1 1/2" diam.Manway                EG&G                        Heat 52763,PN                    N/A         RSO 2554-85,                 N/A Replacement                 No p             Nuts                                                          N93876-0148,                                 SA-194 Gr. 7 t                                                                          0164,-0200 s
7. Description of Work:

The pressunzer manway studs in locations 4 and 8, and nuts in locations 4,8 and 9 failed C.r VT-1 examinations and were , replaced. The new replacement studs and nuts were VT-1 examined with satisfactory rer .ts. l 1 I l

8. Tests Conducted: System Leakace Dressure Test Pressure: 2243 osia Temp: 659'F l

O Nort; Supplenuntal shras a tw fe s of hans, skesches, er drewmss niey be used prowled (I) sue a 8 85 m a 11 m, n) sdormaton in hams a trough 6 en ons report is beluded en sech abset,

3) esub sheet a msnbered W en surnbei of ansets a vosoeded si the top of the form, and (d) each sheet a suaaled and deced Ly the Owner er Oneers desgnee and the AR l

I

p FORM NIS-2 (b:ck) 1

9.- Remarks
None.
                                                 %      u.a.c.m.t e . .= w CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this rentacement conformstotherules of the ASME Code, Section XI.                                      repairor replacement v                                                                                                                                         ;

T3pe Code SytnbolStamp: N/A Cenificate ofAuthorization No: N/A Expiration Date: N/A Signed: Supenisine AShE Codes Eneine_u Owner or Owner's Designee, Title Date: 8 '!M CERTIFICATE OFINSPECTIO'N I, the undersigned holding a valid ecmmission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rtwricht Mutual Insurance comnanv (Factory Mutual Eneineerine A ssociation) of Norwood. Massaebusetts hav9 m1j!pected the components described in thjs Owner's Repon during the period d/#/95 to 7/ 3//93 . and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemmg the examinations and conective measures described in this Owner's Report. Furthermore, neither the Inspector nor his empi er shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or conn ed with ecti , N !I74 Inspector's Signature N Commissions C alifomia II National Board, State, Province, and Endorsements Q I DsteuWJ4tAAk I, I997 i l

                                                                                                                                          \

_ .a_ # 4

g_ l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS p A.a#w w en n an. Asus ca.s m 1.' Owner: Southern California Edison Company Unit- 2  !
 -fs.                         ' 2244 Walnut Grove Avenue                                         MO:       95021534001

( ) Rosemead, California 91770

         '                                                                                       Rspec: EREF-0162,048-95
2. Plant: ' P&ID: 40114D E-4 .

San Onofre Nuclear Generating Station - N-5-' S2-1204 34 San Clemente. California 92674-0128

3. WorkPerformedby: Southern CalifomiaEdison Company T)pe Code SymbolStamp: N/A >

Authorization No: N/A

4. Identification of System: SafetyInjection and Shutdown Cooling Expiration Date*- N/A'
5. (a) Applicable Constmetion Code: ASME Section III. Class 2. I 974 Edition. S'75 AAA=Aa. Code Case: None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition. No A AAmda
6. Identification of Components Repaired or Replaced t.nd Replacement Components:

Repared, ASME_ Name of Name Of Manufacturer National Other Year Replaced or Code Component Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 4" Pow R-Seal Gate WKM 495439 1533 2HV9348 1979 Repaired Yes Valve

7. Description of Work:

g During valve stroke testing if was found that the valve ha'd excessive intemal friction, caused from high spots rubbing between ( the dis / segment assembly and the valve body. The segment foot, segment seating surface and gate were repaired by light

  'v             machining and hand-stoning in accordance with NCR 95020063 to remove the high spots to enable uniform contact between                 -

the segment and the valve body. 1 i l l

                                                                                                                                                          )

l

8. Tests Conducted: System Functional Pressure Test Pressure: 1486 nsin Temp: N/A

(/ w - _ . - _ , _ ,.~e ... .......,_._., . ..

                                                                                                                                         ~

3-i. . _ .r . .a. ..< % .>,.-.uaw ~.,-. - ,,.m

                                                       --                -                                                         a

<- s FORM NIS-2 (b2ek)

9. Remarks : None.

a ' war. om a,an. m n. m CERTIFICATE OF COMPLIANCE , . M M' rep.lr - We certify that the statements made in the report are correct and this-iw:.<cmem conforms to es 7A W W of the ASME Code, Sectior.XI. repairer reptuement Type Code SymbolStamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Siped:. d Sunerv* sine ASME Codes Encineer Date: ' 8/#/ 5 I Owmer or Owner's Desipee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht Mutual Insurance Comoany (Factory Mutual . -- Eneineerirm Association) of Norwood. Massachusetts have inspected the components described in this Owner's Rep during the period .2/JJ/9_f to 6/4 M S . and state that to the best ofmy knowledge and belief, the Owner has perfonned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conce examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his empipfer shallbeliable y manner for any personal injury or property damage or a loss of any kind arising from or conn!ct wi wtion. auE Inspectors Signature

                                      -G              Commissions                      1 5 7 4 Caiifomia N         tl National Board, State, Province, and Endorsements              g 1

Det.1_ Lu$ b , $ U$ ve l l l 1 l l l I m: escrisumi l

e FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As a wer as e- a was ARE Cds Samu'G hastlef t

1. Owner: Southern CaliforniaEdison Company Unit: 2 1 O 2244 Walnut Grove Avenue MO: 95021577000 i R-> California 91770 Rspec 036-95 l P&lD: N/A
2. Plant: San Onofre Nuclear Generating Station N *"* S2-1204-5 San Clemente, California 92674-0128  ;

1

3. Work Performed by: Southern California Edison Cornpany Type Code SymbolStamp: N/A

{

4. Identi6 cation of System: SafetyInjection and Shutdown Cooling Authornation No: N/A Expiration Date: N/A l i
5. (a) Applicable Constmetion Code: ASME Section IIL Class 1-NR 1974 Edition. S'74 Addmda Code Case: None (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989Edjtion H2 Addenda
6. Identi5 cation of Components Repaired or Replaced and Replacement Components:

Repaared, ASME Name of Name Of Manufacturer National

  • Other Year Replaced er Code Camponent Wa=w Seria!No. Board No. Idani6 cation Built Replacemeri Stanged Yes/No i

MechanicalSnubber Paci5c Scienti6c 17082 N/A S2S1043H01SB 1985 Replaced No PSA 104 Mechanical Snubber Pacific Scientific 17 % 3 N/A RSO 1352-91 N/A Replacement No-PSA 10-6

7. Description ofWork: .

d The mechanical snubber was replaced in accordance with NCR 95020078 aAer failing Man =1 testing. The snubber , assembly was visually av==~aad (VT-3) aner installation with satisfactory results. i I

8. Tests Conducted: HM Pressure: H% Temp: U!A
     /
            -ware      su,,ianant sh== = en == orhm.shashus er e                                                       s y be i pn=esd c) us.. m A : =,a> w-in n. s : er.oh 4 en s= =part h indde en och sheet,
3) anch shest b assubmed and an =subar afahese h nosided e eu top of 8ms % sad (4) assh shese is amended and ested by tu owner er Osmar's emmener eid su ADL

FORM NIS-2 (baek)

9. Remarks : None.

v.; - :, w.m w w CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this relacement conformstothe rules of the ASME Code, Section XI. repair orreplacement Type Code Symbol Stamp: N/A Certificate of Authorization No: N/A Expiration Date: N/A Signed: /) Stmervisinc ASME codes Encineer Date: ___4 17b Chmer or Oume(s Designee, Title 'I ' CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsursnee Comoanv Tsetory Mutual Encineerine A ssociation) of Norwood. Massschusetts have inspected the components desenhd in this Ownefs Report during the period S/S6/9S to 4///#/95 . and state that to the best of my knowledge and belief, the Owner has perfo/med ex'aminations and taken cor(ective measures desenhd in this Owner's Report in accordance with the requirements of

he ASME Code, Section XI.

By signing this certi5cate, neither the Inspector ner his employer makes any warranty, sg M or implied, concemmg the examinations and corrective measures described in this Ownefs Report. Furthermore, neither the Inspcx: tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or comected with this impection. M /// ~ Commissions /#4O California Inspector's' Signature / NationalBoard, State Province,andEndorsements Date/)Alf/$,$$ W: 95 ens 77Dpo O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS asaw$ro Pron .ra.mac.e s =x ShastI of1

1. Owner: Southern California Edison Company Unit: 2 i 2244 Walnut Grove Avenue MO: 95021655000 j Rosemead, California 91770 Rspec 038-95
2. Plant- San Onofre Nuclear Generating Station P&ID: 40lllA San Clemente, California 92674-0128
S2-120b3-11
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A
4. Identi5cationofSystem: ReactorCoolant Authorization No: N/A ExpirationDate: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 1-NF.1974 Edition. S'74 Addenda. Code Cases: None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired. ASME Name of NameOf Manufacturer National Other Year Replaced or Code Componers Manufacturer Seria! No. Board No. Identification Buik Replacement Stamped Yes% Mechanical Snubber Pacific Scientific 30635 N/A S2RC147H001B 1989 Replaced No PSA 3 - 5 Mechanical Snubber Pacific Scientific 30483 N/A RSO 3895-86, N/A Replacement No PSA 3 - 5 CR-88-001, CCase

                                                                                .                                                                       1644-7 fm      Mechanical Snubber                               Pacific Scientific 30701                                                             N/A     S2RCl47H001T              1991      Replaced        No

( ) PSA 3 - 5

 'v'      Mechanical Snubbe.r                              Pacific Scientific 30713                                                             N/A     RSO l890-91,              N/A Replacement           No l

PSA 3 - 5 CCase 1644-7 . I J

7. Description of Work:

The mechanical snubbers were replaced in accordance with NCR 95020088 after failing functional testing. The raubber assemblies were visually examined (VT-3) after installation with satisfactory results.  ; l 1

8. Tests Conducted: M Pressure: M Temp: M (v mnt w u
  • a. f-. .a a . r w.d , a.d m - s i n . n x m - m - i .,-.h d e- ,-i . - a.a.
3) each shese a msnbered and en aanbe of sheets m .unarded at the top of eus fara and M =ach sheet a reenned and dated by the Owner er Owne's desgner and the AIA

sr.+ *4N E .M.,

  • p t F ,*h e s > ** * * * . r-
  • FORM NIS-2 (b:ck) r
9. Remarks : CR-88-001 r-dles the replacement snubber SN 30483, which was certified to ASME III-I NF,1974 Edition, S'76 Addenda.

w+ ~, o,. n,a. ,, m > CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reniacement conformstothe rules of the ASME Code, Section XI. repair orreplacement Type Code Symbol Stamp: N/A Certificate ofAuthorization No: N/A ExpirationDate: N/A Signed: 4 Suoervisine ASME Codes Encineer Date: M/2/96 Owner or Owner's Designee, Title CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwriebt Mutual Insurance Company (Factory Mutual Enrineerine Association) of Norwood. Massaebusetts have inspected the components desented in this Owner's Report during the period S/M/GC to '7//-7AR6 . and state that to the best of my knowledge and belief, the Owner has perforrried exaininations and taken corrective measures described in this Owner's Report in accordance with the requirements of te ASME Code, Section XI. By signing this certificate, neither the Inrpector nor his employer makes any w3rranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mpection. MM Commissions /YU Califomia Inspector'sSignature / g National Board, State, Province, and Endorsements

                                                          \

Date A f / -1 / B M 61 (/ ' 9

a e' d FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS . As sequmed by b Pronnes etas ASME Code **vt Spot IafI

 ,,-      1.- Owner: Southern CaliforniaEdisonCompany                                                                                        Unit- 2

'( 1 2244 Walnut Grove Avenue MO: 95021661000 (/ Rosemead, California 91770 Rspec: EREF-0255 P&ID: 40111C G-5

2. Plant- San Onofre Nuclear Generstmg Station San Clemente, California 92674-0128 y,3'. S2-1901-2
3. WorkPerfonnedby: Southern CaliforniaEdison Company TypeCode SymbolStamp: N/A i 4.- Identification of Sys*em: Pnnary Plant Makeup A No: N/A
5. (a) Applicable Construction Code: ASME Section III. Class 2.1974 Edition. S'73 AAAmda Code Case None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda i i
6. Identification of Components Repaired or Replaced and Replacement Cumycocats-l I

Repased. ASME' l Nameof' NameOf Manufacturer National Other Year Replaced er Code Component Ma=#enww Serial No. Board No. Manen&=non Built R ;- - Stamped , Yes/No 2' Y-type Check Kerotest MA7-6 N/A S21901MU573 1976 - Yes Valve  ; Disc Kerotest APG6-2 N/A RSO 2552-93, PN 1993 Replacement Yes 72609092 Cover BW/IP 304240 N/A RSO 2852-93, PN 1993 Replacement Yes j International 72609050 {% l V) 7. Description ofWork: l

                                                                                 \

The check valve was disassembled for inspection after failing its 11RT as documented in NCR 95020091. Thevalve cover and disc were replaced and the valve reassembled. l I l i l l l

8. Tests Conducted: System Functional Pressure Test Pressure: 60.5 esia Temp: N/A _
 /

(

s. .

No!T. Sepplememm1 sheen in tar form ernen, ekst&as, or eewings may be used provided 0) siar is 8 IfJ in m II in. (2)mfemmehen a limus I $seegh 6 en $as ppert is included ca ensb abast, 3)ensk shese s seenbermt and en munbar of sheen a neerdsd a the kg of tes fem and (4) enc 6 aben s humansd and duasd by es Owaar er Owns's desense and the A1A

FORM NIS-2 (back) *

9. Remarks : The replacement items were certiSed to ASME III.1 as allowed by ASME IIL paragraph NCA I m -
                                                               . um       ., s. e.o CERTIFICATE OF COMPLIANCE We certzfy that the <me made in the report are correct and this replacement of the ASME Code, Section XI. -                                                    conformstothe rules repairorreplacement Type Code, Symbol Stamp: N/A CertificateofAuthorization No: N/A                 ExpirationDate: N/A Signed:                    'M Outer or Owix:r's Desim. Title Surevisine ASME codes Encirar              Date:        S// M95 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pn:ssu or Province of California. and employed by Arkwricht Mutual Insurance Companv (Factory Mutual Enrine A ssociation)

S/S4/GC of Norwood. to S //RMassachusetts M have inspected the wwycaents descdbed in this Ow

                                                       . and state that to the best ofmy knowledge and belief, the Owner has perform'ed the               examinations ASME Code, Section    XL        and taked correictive measures desenkd in this Owner's Report in By signing this certificate, neither the Inspector nor his employer makes any wwranty, spJ be liable in any manner for any personal injury or property damage tnspection.

A0 erd #>r Commissicas /8[ef Inspesor's'SiE nsture/ California National Board, State, Prmince, and Endorsements DateMI,///. //,. /Mf k. . 1

                                                                                                                     .         \

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

4. a., d by en t==-.rew ASME Cads sectaOG shed 4 ef &
1. Owner: Southem California Edison Company Unit: 2
 ,    N,                        2244 Walnut Grove Avenue                                                                     MO: 95021798000 (j-                            Rasemad.Califomia 91770                                                                      Rspec 043-95 P&ID: 40112C
2. Plant: San Onofre Nuclear Generating Station N-5: S2-1204-32 San Clemente, Califomia 92674-0128
3. WorkPerformedby: Southern California Edison Company T3pe Code Symbol Stamp: N/A AuthorizationNo: N/A
4. Identification of System: Safety Injection and Shutdown Cooling
5. (a) Applicable Construction Code: ASME Section IIL Class 1-NF.1974 Edition. S'74 Addenda. Code Cases: 1644-7

, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition.No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Repaired, ASME Name of Name Of Manufacturer Nanonal Other Year Replaced or Code Component Manufacturer SerialNo. Board No. Idendrication Built Replacement Stamped Yes/No Mechanical Snubber Pacific Scientific 25772 N/A S2Sil65H006 1986 Replaced No PSA 1 - 4 Mechanical Snubber Pacific Scientific 25764 N/A RSO 1704-86 N/A Peplacement No PSA l - 4

7. Description of Woric

( ~ Ihe mechanical snubber was replaced as a preventative maintenance action. The snubber assembly was visually examined (VT-3) after installation with satisfactory results. The removed snubber was placed into the snubber rebuild program.

8. Tests Conducted: E!A Pressare: E!% Temp: E!%

i

  's     - _ . _               _-.                                                   ,._dm             .....                 _         .s,~.              - ~

n 3)och s' eet a numbered and om numbe of shoes a vuoarded at du top of em larm and (4) each shest s inranied and daind by em Owns er Osmer's dessnee and tu AR

l FORM NIS-2 (b:ck)

9. Remarks: None.
                                         -            w um.= a,                i, %

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement confonnstothe rules of the ASME Code, Section XI. - repairorreplacement Type Code SymbolStamp: N/A Certdicate ofAuthorizationNo: N/A Expiration Date: N/A Siped: / , Ie Supervisine ASME Codes Ennneer Owner or Owner's Designee, Title Date: #[# 95 CERTIFICATE OFINSPECTION r, the tmdersigned holding a valid commissica issued by the National Board ofBoiler and Pressure Vessel Inspectors and the State or Province of California. and employed by Arkwricht MutualInsurance Comnany (Factory Mutual Enrincerine A ssociationbf Norwood. Massachioetts hs 'e 2 inspected the components described in this Owner's Report during the period J/#WQE to__ 60 / 9 / C M . and state that to the best ofmy knowledge and belief, the Owner has perfofmed cixaminations and taken' corrective measures described in this Owmer's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his empicyer makes any warranty, era orimplied, conceming the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. d w441#n- ' Commissions 42 California Insim: tor's Signatur/ National Board, State, Province, and Endorsements

                       -     f 9

WJ' 950217M000 9,

                           . FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u a.,*.e er e. p=*             efes ASME Cok Semi.XI amaaeo                                                          !
1. Owner: Southem California Edisco Company Unit: 2 ,

'7 / 2244 Walnut Grove Avenue MO: 95021927000

  • Q' Raarma*A,Califamia 91770 Rspec: 045-95 P&ID: 40113B
2. Plant: San Onofre Nuclear Generating Station N-5: ' S2-1204-9 San Clemente, Califamia 92674-0128
3. WorkPerformedby: Southern CaliforniaEdison Company Type Code SymbolStamp: N/A  ;

AuthonzationNo: N/A i ExpirationDate: N/A i

4. Identi5 cation of System: SafetyInjection and Shutdown Cooling .
     . 5. (a) Applicable Construction Code: ASME Section III. Class 2-NF.1974 Edition S'74 Addanda Code Cases: 1644-7 (b) Applicable Edition of Section XI Utihzed for Repairs or Replacements: 1989 Edition No Addenda                                                                            !
6. Identification of Components Repaired orReplaced and Replacement Components:

Repared. ASME Name of Name Of Manufacturer National Other Year Replaced or Code Ce Manufacturer Seria1No. Board No. Identification Built Replaosment Stamped i YesWo Mechanical Snubber Pacific Scientific 38665 N/A S2SIO74H002 1991 Replaced No PSA 1/4 -4 Mechanical Snubber Pacific Scientific 38687 N/A RSO 0522-92 N/A Replacement No PSA 1/4 -4

7. Description ofWork:

The mechanical snubber was replaced as a preventative maintenance action. The snubber assembly was visually exammed (VT-3) after installation with satisfactory results. The removed snubber was placed into the snubber rebuild program.

                                                        ~

1 l i i l 1 l l 1 1 1

8. Tests Conducted: N/A Pressure: N/A Temp: E!A r

(-

    - - . - wes-                                                                                  .e,....               _ ,._g,d.s-.---

3)es:b sheet is nurnband and su numbs af shose is pseuded at the eup arts farm. and (d) each sheet e irutaled and deind by em osmer w owner's desgnse and tw AR

l FORM NIS-2 (b:ck)

9. Remarks : Ibe rep!scement snubber was certified to ASME m-1 NF as allowed by ASME m, paragraph NCA-2134.
v. --_n w .u m CERTIFICATE OF COMPI, LANCE We certtfy that the statements made in the report are correct and this replacement caformstothe rules  !

of the ASME Code, Section XI. - repairorreplacement ' Type Cooe SymbolStamp: N/A Certi5cate ofAuthorization No: N/A ExpirationDate: N/A Signed: / d Owner or Owner's Designee, Title Sunervisine ASME Codes Encineer Date: 4 I CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwriebt MutualInsurance Company (Factorv Mutual Enrineertar AssociatbnJp/Chf f/MK Norwood. Massschusettslave inspected the components described in this Owner's Report to 6/6//9C . and state that to the best ofmy knowledge and belief, the Owner has perfofmed examinEians and takes caricetive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certi5cate, neither the Inspector nor his employu makes any warranty, exprencd or implied, concerning the exartdnations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this aspection.

               ,   #M4/24n t                 '

Commissions /B4> 2. Califomia Inspector's Signature [ National Board, State, Province, and Endorsements Date ,ut V /W(

         /             '

6 i _ l % esanmoco . 1 1 1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1 Aswbye enm m..re.4:usc. des.amoa

1. Owner: Southern CaliforniaEdison Company Unit: 2 7- -

2244 Walnut Grove Avenue MO: 95021980000 { Rosemead, California 91770 Rspec: EREF-0118

2. Plant: San Onofre Nuclear Generating Station P&ID: 40134A G-7 San Clemente, California 92674-0128 N-5' S2-1212-5 '
3. WorkPerformedby: Southern California Edison Company Type Code SymbolStamp: N/A Authorization No: N/A-Expiration Date: N/A
4. Identification of System: Nuclear Plant Sampling i
5. (a) Applicable Constniction Code: ASME Section III. Class 2. I 974 Edition. S'74 Addenda. Code Cases: 1713 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components:

Repared. ASME_ Name of Narne Of Manufacturer National Other Year Replaced or Code Corgonent Manufacturer Serial No. Board No. Identification Built Replacement Stamped Yes/No 3/4" Globe Valve WKM 70-117799 1209 2HV0517 1977 -- Yes 3/4" Valve Plug Anchor / Darling Ht. A794 N/A RSO 0738-94, N/A Replacement No (Disc) Stellite 6B i

7. Description of Work:

O d The valve showed evidence ofboric acid leakage and was disassembled. The valve plug broke during disassembly and required replacement. P l i l l

8. Tests Conducted: System Functional Pressure Test Pressure: 2256 osia Temp: FjA NUTE. ".,,

f sheets a du kun ofism. Aab es drawags any be used prouded (I)sias s 8 IfJ st a !! st Q) mformation in hems ! Osough 6 on em repet s included on each shee

3) each sheet a numbered and en nonbar of sheen is moorded at tw top of the form, and (4) each short is subaled and dated t'y ou Owner er Owners demanee and om A1

FORM NIS-2 (b:ck)

9. Remarks : None.

e we. = % w w CERTIFICATE OF COMPlJANCE We certify that the statements made in the report are correct and this renlacement confonnstotherules of the ASME Code, Section XI. repair er reptu=mers Type Code SymbolStamp: N/A Certificate ofAuthonzation No: N/A Expiration Date: N/A Signed: Owner or Owner's Designee. Title Sunervisine AShE Codes Encineer Date: B[7 Jf CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Comnanv (Factory Mutual - Enrincerior Assoelation) of Norwood. Massachusetts have inspected the components desented in this Owner's Report during the period M/2/95 to ,8 /*7/ W . and state that to the best ofmy knowledge and belief, the Owner has p4rforined examinations and ta' ken'cenective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Outer's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                      /2md2dayt                      Commissions /d%2.                           Califomia Inspector's' Sigriature /
                                      ~

National Board, State. Prosince, and Endorsements Date -- (01/A,. . 7/55

s Comiserto FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS u n i.ed by e r- m.orsu ASME Caen Sees 00 m 1. Owner: Southem California Edison Company Unit: 2
                            . 2244 Walnut Grove Avenue                                                                MO: 95030412000 (h'

Rosemead, California 91770 Rspec 058-95

2. Plant: San Onofre Nuclear Generating Station P&ID: 40ll3A San Clemente, California 92674-0128 S 42M
3. WorkPerformedby: Southern Califamia Edison Company Type Code Symbol Stamp: N/A '  ;

Authorization No: N/A l Expiration Date- ' N/A

4. Identification of System: SafetyInjection and Shutdown Cooling
5. (a) Applicable Construction Code: ASME Section Ill Class 1-NF.1974 Edition. S'74 Ad4da Code Caea None _

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989 Edition. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:
                                                                                                                                                                      , Repaired,
                                                                                                                                                                         ,                  ASME_.

Name of NameOf Manufacturer National Other Year Replaced or Code Component Manufacturer SerialNo.- Board No. Identification Built Replacement Starrged Yes/No Mechanical Snubber Pacific Scientific 2587 N/A S2SIO64H030 1978 Replaced . Yes PSA 1/2 - 21/2 Mechanical Snubber Pacific Scientific 20702 N/A RSO 2192-92, N/A Replacement No ~ PSA 1/2 21/2 CCase 1644-5

 ,m                                                                                                                                                                                                 !
7. Description of Work:

The mechanical snubber was replaced in accordance with NCR 95030040 after dif!Iculties experienced during functional testing. The snubber assembly was visually examined (VT-3) after installation with satisfactory results. The removed snubber was placed into the snubber rebuild program.

8. Tests Conducted: M Pressure: M Temp: M O

v N(TTE " _ , , tal sheet a Sw farin afhsts, skmches, or drawags may be W pnmded (I) mas s 8 t/J si a Il st, o) si hans I through 6 an the repet is suluded en suh shest,

3) and shre a nurnbend and the number of shoes is sesorded at du top of has fang, and (d)each shed a sesled and dated by tw Owner er Owner's desgnee and the AIA
                    ..;: / w.:-                                                                                       CORRECTED FORM NIS-2 (b:ck)                                                             .
9. Remarks: None.

m --. a. m,.on, i. - CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this renlacement conformstotherules of the ASME Code, Section XI. npair cenplument Type Code 3S mbol Stamp: N/A Certificate ofAuthorizati No: N/A Expiration Date: N/A Siped: (/r* Owner or Owner's Designee, Title mervisinc ASME Codes Eneineer Date: 8!.3[36 CERTIFICATE OFINSPECTION I, the undersigned holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California. and employed by A rkwricht Mutual Insurance Companv (Factory Mutual . .- Encineerine Associationi of Norwood. Massachusetts have inspected the components described in this Owmer's Report during the period _3/#/96 to E/4/94~ . and state that to the best of my knowledge and belief, the Owner has performed examinations and tsken corrective measures oescribed in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, med or implied, conceming the examinations and corrective measures described in this Owner's Report. Funbermore, neither the Inspector nor his employer shall be liatle in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thisinspection. [ >Sweh ~ Commissions /I4A Califomia Inspector's Signature / National Board, State, Prosince, and Endorsements Date bl,66& A. /.9W 4 4}}