,a
- 1' j
l GPU Nuclear Corporation j
g g gs Post Office Box 388 i
MB Route 9 South Forked River,New Jersey 08731-0388 609 971-4000 i
Writer's Direct Dial Number 1
August 15,1995
)
C321-95-2250 i
U.S. Nuclear Regulatory Commission 1
Attention: Document Control Desk j
Washington, D.C. 20555
Dear Sir:
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219 Monthly Operating Report - July,1995 I
In accordance with the Oyster Creek Nuclear Generating Station Operating License No. DPR-16, Appendix A, Section 6.9.1.C, enclosed are two (2) copies of the Monthly Operating Data (gray book information) for the Oyster Creek Nuclear Generating Station.
If you should have any questions, please contact Brenda DeMerchant, Oyster Creek Licensing Engineer at (609) 971-4642.
incere f
,}
^
Joli i J. Etrj.on Vi e PresWient and Director I
ster Cirek JJB/BDEM Attachment cc:
Administrator, Region 1 Senior NRC Resident Inspector Oyster Creek NRC Pmject Manager 9508220310 950731 PDR ADOCK 05000219 R
PDR GPU Nuclear Corporation is a subsidiary of General Public Util! ties Corporation i
~ '.
.t,
SUMMARY
July,1995 There were no significant power reductions during July at Oyster Creek.
However, minor power reductions due to environmental discharge temperature
~
limits occurred throughout the month. During the month, Oyster Creek generated 438,119 net MWH electric and attained a MDC net capacity factor of 95.1%.
{
h i
l' I
g.
MON'ITILY OPERATING REPORT LICENSEE EVENT REPORTS No LER's were submitted during the month of July 1995.
i i
l l
fi
.,t:
J*;s Oyster Creek Station #1 Decket No. 50 219 REFUELING INF0llMATION JULY,1995 Name of Facility: Syster Creek Station #1 Scheduled dets for next refueling shutdown September,1996 Scheduled date for restart following refueling: Currently projected for November,1998 Will refueling er resumption of operation thereafter require a Technical Specification change er other license amendment?
No important licensing considerations associated with refueling, e.g., new or different fuel desip er supplier, unreviewed design er performance analysis methods, significant changes in fuel design, new operating procedures:
1.
General Electric Fuel Assemblies Fuel design and performance analysis methods have been approved by the NRC.
The number of fuel assemblies (a) la the cors 580
=
lb) la the spent fuel storega peel
= 2049 (c) in dry storage
=. 24 '
The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies:
Present Licensed Capacity: 2845 The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:
Full core discharge capacity to the spent fuel pool will be ovellable through the 1998 refueling outage.
{L s
't-3.,.
L AVERASE DAILY POWER LEVEL NET MWe DOCKET #........... 50 219 UNIT......... SYSTER CREEK #1 REPORT DATE......... Bl4195 COMPILED BY....... PAUL EDELMANN TELEPHONE #...... 508 9714097 MONTH: JULY,1995 E
M M
M 1.
818 18.
597 2.
818 17.
591 3.
' 518 18.
584 4.
815 19.
805 i
5.
808 20.
808 8.
594 21.
808 7.
801 22.
804 8.
807 23.
590 9.
813 24.
580 10.
813 25.
548 11.
811 28.
513 IL 811 27.
529 13.
805 28.
507 14.
808 29.
518 15.
582 30.
588 31.
587
r Je :
fS:
OPERATING DATA REPORT l
OPERATING STATUS
' 1.
D')CKET:
50 219
- 2. ; REPORTING PERIOD: Jul 95 i
3.
UTILITY CONTACT:. PAUL EDELMANN (809-0714097).
4.
LICENSE 0 THERMAL POWER WWt):
1930 -
5.
. NAMEPLATE HATING (GROSS MWel: 887.5 x 0.8 = 550 8.
DESIGN ELECTRICAL RATING INET MWel: 850 s
7.
MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 541
- 8.
MAXIMUM DEPENDASLE CAPACITY INET MWe): 8tt 8.
IF CHANGES OCCUR AB0VE SINCE LAST REPORT, GIVE REASONS:
NONE
- 10. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWe):
NONE l
- 11. REASON FOR RESTRICTION,IF ANY:
NONE MONTH 1188 CUMULATIVE
- 12. REPORT PERIOD HOURS 744.0 5087.0 224447.0
- 13. NOURS RX CRITICAL 744.0 5087.0 150887.7
- 14. RX RESERVE SHUT 00WN HRS 0.0 0.0 918.2
- 15. NRS GENERATOR ON-LINE 744.0 5087.0 147388.1
- 18. UT RESERVE SNTOWN NRS -
0.0 0.0 0.0
- 17. GROSS THERM ENERGY WWH) 1197395 9577103 254100807
- 18. GROSS ELEC ENERGY NWM) 455211 3237197 85283488 II. NET ELEC ENERGY WWM) 438119 3121079 81798188
- 20. UT SERVICE FACTOR 100.0 100.0 85.7
- 21. UT AVAll FACTOR 100.0 100.0 85.7
- 24. - UT FORCE 0 OUTAGE RATE 0.0 0.0 10.0
- 25. FORCEO OUTAGE HRS 0.0 0.0 18289.8
- 28.. SHUTOOWNS SCHEDULE 0 OVER NEXT $ MONTHS (TYPE, DATE, DURATION):
NONE
- 27. IF CURRENTLY SHUT 00WN, ESTIMATED STARTUP OATE: NlA
ilI!
.lIjq jjilI'll1lll il;l 1lll1i!1llfl)ll' s
o.
rg S
en T
wi M
or E
opug M
t d n t
M t
ecoo.
TS wiip CN f t ed EO eicro RI rnu i RT egd er oC hieh e CA T srt p 5
9 R
9 n
cO) k 1
a N
2 e
r IR(
e
. E TO r 4 TTR C
1
. 8 vCE sAW M
1 9
r t
8 SEO 1
e s d 4
RP 2
t u
i 7
s r v 1
0EG 0
v u
a 7
HN 5
O A D 9
nTI o
C sNU TWD EOE B :
MDR Y
oE E
NM
- O DN A
TM TB E
- LF m)
KTEPE a n
)
CITML ri 1
ONAOE mca
(
S DUDCT aSl N
r p
N O
ccx O
S SiE I
A t (
T E
Dll a C
R O aamr TID H uuoe E
T nnth R
E aaut MMMAO R
E
)
(
P DN N
A O )s S
Tu
~
I r
N A o d
R 6
U h D(
m u
a
)
x n
u r.
E ia S
e l
T i
p L
x IN E
U
(
g r
n o
i r) nern i vEi ai a
rtll d
E e
Taaprnx r
l rt oE Td u Ted osi(
t i t ce rh ana r rire oc FS emeh pd pt OAOO FS
.. gh ef..
)n i
E a
T l
A p
n 5
D x
o 9
E i
9
( t t
1 s
c ee.i y
rT r
l u
t u
l r s
J i o e
a R
F e c
y t ngr nano E
enit T
N pt el mel a N
o O
N O i nuu M
- S uif g YA qae e T
RE EMRR R
M),
R O
P E
L1 abcd R
S(
e l!l.
l ll
'