ML20087J837
| ML20087J837 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 01/31/1984 |
| From: | Belmore C, Hillman R Battelle Memorial Institute, PACIFIC NORTHWEST NATION |
| To: | |
| Shared Package | |
| ML20087J830 | List: |
| References | |
| NUDOCS 8403230112 | |
| Download: ML20087J837 (24) | |
Text
_
4 PROGRESS REPORT FOR THE THIRTY-FIFTH QUARTER On STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK GENERATING STATION To GPU NUCLEAR CORPORATION February 29,1984 by R.E. Hillman and C.I. Belmore REPORT NO.15220 October 21,1983 to January 31,1984 i
l BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts 02332 Battelle is not engaged in research for advertising, sales promotion, or publicity purposes, and this report may not be reproduced in full or in part for such purposes.
8403230112 840316 PDR ADOCK 05000219 R
A TABLE OF CONTENTS EX EC UR VE SU M M A RY.....................................................
i j
IN T RO D UCTION............................................................
1 PROCEDURES AN D INTERIM DATA..........................................
2 E==>re Panels.......................................................
2 Water Quali ty.........................................................
2 Teredinid Gonadal Development Studies...................................
2 LIST OF TABLES Table 1.
Geographical Locations of Exposure Panel Arrays in Barnegat Bay, N ew Jersey.................................................
4
)
Table 2.
Incidence of Teredinidae in Panels Removed November 7-8, 1983.......
8 Table 3.
Incidence of Teredinidae in Panels Removed December 5-6, 1983.......
9 Table 4.
Incidence of Teredinidae in Panels Removed January 9-10,1984........
10
(
Table 5.
Incidence of Limnoria in Panels Removed November, December,1983 and J anuary, 198 4................................................
11
(
Table 6.
Water Quality at Exposure Panel Stations, November 7-8, 1983.........
12 Table 7.
Water Quality at Exposure Panel Stations, December 5-6, 19 8 3.........
13 I
Table 8.
Water Quality at Exposure Panel Stations, January 9-10, 198 4..........
14 Table 9.
Condition of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from October through December,1983.........
15 L
LIST OF FIGURES s
Figure 1.
Outline of Barnegat Bay Showing Geographical Locations of r-Exposure Panels.................................................
3 L
?
f
l L
L i
EXECUTIVE
SUMMARY
This progress report presents data from field and laboratory work during the period October 21,1983 to January 3.,1984.
All field work during this quarter was carried out by GPU Nuclear personnel.
{
Temperature, salinity, dissolved oxygen and pH were measured and recorded at each of the 20 stations during the three periods of exposure panel exchange.
Exposure panel racks at Stations 1 and 7 were moved to different locations on the same docks. Station 8 and 9 were relocated to other sites. Station 3 was moved about 2,000 feet further away from the generating plant and Station 9 was moved about 2,000 feet closer to the plant.
No Teredo bartschi were found in any of the exposure panels examined from Barnegat Bay during 1983.
No unusual patterns of gonad development were noted for the months of October, November, and December,1983.
l 1
k
r 1
L PROGRESS REPORT FOR THE THIRTY-FIFTH QUARTER on STUDY OF WOODBORER POPULATIONS j
IN RELATION TO THE OYSTER CREEK GENERATING STATION to f
GPU NUCLEAR CORPORATION February 29,1984 by Robert E. Hillman and C.I. Belmore l
REPORT NO.15220 October 21,1983 to January 31,1984 from BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts 02332 INTRODUCTION Battelle's New England Marine Research Laboratory is conducting an investigation to determine whether the generating station is affecting the resident marine borer population in Oyster Creek to the extent that that population is contributing significantly to marine borer-caused damage in Barnegat Bay.
A description of the program and procedures used may be found in the seventh annual report titled, " Study of Woodbcrer Populations in Relation to the Oyster Creek Generating Station", dated May 15, 1983.
This report presents data for the thirty-fif th quarterly period from October 21,1983 to January 31,1984.
{
I L
2 PROCEDURES AND INTERIM DATA Exposure panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods of November 7-8, December 5-6, 1983, and January 9-10, 1984. Long-term and short-term panels at all stations were retrieved and replaced by personnel from GPU's Oyster Creek Nuclear Generating Station.
I At the time of the November,1983 panel exchange period, the exposure panel rack at Station 1 was moved to the opposite side of the bulkhead and about 40 feet closer to shore. The exposure panel rack at Station 7 was re19cated to the end of the same dock into deeper water. Station 8 was changed to a company-owned dock about 2,000 feet nearer to the mouth of Oyster Creek. Also, Station 9 was changed to company-owned property about 2000 feet closer to the Oyster Creek Nuclear Generating Station.
Table 1 describes the geographical locations of the exposure sites. Data from the laboratory examination of the panels are presented in Tables 2 through 5.
Water Quality Salinity, water temperature, dissolved oxygen and pH were taken at each site by the GPU Nuclear field team.
Results wr November, December, 1983, and January,1984 are presented in Tables 6 through 8.
Teredinid Gonadal Development Studies Table 9 shows the gonad condition of teredinid borers collected in October, November, and December,1983. Included are results from panels exposed for periods ranging from 6 to 12 months. No unusual patterns of development were observed.
0
3 MANASOUAN INLET SQiELLE b
O POINT 4 AS PLEASANT r
(
INT A ACO ASTAL -
WATE AWAY CAN AL MANTOLOKING 15 KETTLE CAEEK 0
Do 8
SEASIDE
/ f SLOOP l
ATLANTIC OCEAN HOLLY PARK O*
STOUTS CAEEK 108
['
LEDGE 10 ISLAND Q10A o
[5$
OYSTER 6
BARNEGAT INLET OYSTER CREEK NUCLEAR GENERATING t BARNEGAT WARETOWN CITY 4
BAANEGAT BEACH CONKLIN
$ PANEL ARRAY ISLAND 0
2 3
I MILES BARNEGAT INLET. NEW JERSEY Latitude 39 45 8 N Longitude 74 06 0 W 2
l4 k
FIGURE 1. OUTLINE OF BARNEGAT BAY SHOWING GEOGRAPHIC LOCATIONS OF EMOSURE PANELS
TABLE 1.
GEOGRAPHICAL LOCATIONS OF BATTELLE NEW ENGLAND MARINE RESEARCH LABORATORY'S EXPOSURE PANEL ARRAYS IN BARNEGAT BAY, NEW 3ERSEY I
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude i
l l
l 1.
Barnegat Coast Guard Finger Pier WC1 Lat. 390 45.8'N Station, Barnegat Inlet Bulkhead WFCL 1948-1967 Long. 740 06.5'W I
2.
Ashton Marina Bulkhead WC 13,14 Lat. 390 40'N l
1450 Bay Ave.
Long. 74013'W Manahawkin 3.
Iggie's Marina Bulkhead WC 16,17,18,19 Lat. 390 45'N East Bay Ave.
Long. 740 12.5'W Barnegat (Conklin Island) 4.
Liberty Harbor Marina Bulkhead WC21 Lat. 390 47'N Washington Ave.
R. Turner Long. 740 ll'W Waretown Rutgers U.
4-A *.
Holiday Harbor Marina Bulkhead WC 21 Lat. 390 48'N Lighthouse Drive R. Turner Long. 740 ll'N Waretown Rutgers U.
5.
Mouth of Oyster Creek, Dock WC 29, 30 Lat. 390 48.5'N Lot 4, Compass Road Rutgers U.
Long. 74010.3'W Offshore End j
6.
Oyster Creek i Dock Lat. 390 48.5'N Lagoon, Inshore End Long. 7t:0 10.35'W 37 Capstan Drive
TABLE 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 7.
Private Dock End of Dock WC 27,28 Lat. 390 48.5'N Dock Ave.
R. Turner Long.74 l l. I'W Oyster Creek Rutgers U.
Sands Pt. Harbor Waretown 8.
Oyster Creek Bridge Bulkhead 1500 ft.
WC 26 Lat. 390 48.7'N Discharge Canal east of the R.R.
Long. 74012'W bridge 9.
Forked River Metal pier WC 31 Lat. 390 49.2'N South Branch Long. 74012.2'W ui Intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 390 50.I'N Bay Ave.
Long. 74011.6'W Forked River l
10A *.
Private Dock Under Dock Lat. 390 49'N l
1217 Aquarius Ct.
Long. 74010'W Forked River 10B*.
Private Dock Under Dock Lat. 390 49.4'N 1307 Beach Blvd.
Long. 74010.I'W l
Forked River 11.
Forked River Bulkhead Wc 35 Lat. 390 49.7'N (near mouth)
Rutgers U.
Long. 74010'W 1413 River View Drive
TABLE I. (Continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 12.
Stouts Creek Bulkhead WC 38, 40, 41 Lat. 390 50.5'N 1273 Capstan Drive R. Turner Long. 740 08.8'W Wurtz Rutgers U.
13.
Rocknak's Yacht Basin End of Pier WC 46 Lat. 390 52'N Seaview Ave.
Long. 740 09'W Lanoka Harbor Cedar Creek 14.
Dicks Landing Pier WC 49 Lat. 390 54'W Island Drive R. Turner Long. 740 08.I'W Bayville (Holly Park)
Nelson 15.
Winter Yacht Basin Inc.
Pier WC 57 Lat. 400 02.5'N Rt.528 Long. 740 04.9'W Mantoloking Bridge 16.
Berkely Yacht Basin Pier WC 60,61 Lat. 390 55.9'N
- 3. Street Long. 740 04.9'W Seaside 16A *.
Municipal Dock Pier WC 60,61 Lat. 390 56.6'N Seaside Heights Long. 740 04.9'W 16B*.
Bayside Boats Pier WC 60,61 Lat. 390 36.6'N State Highway 35 and Long. 740 04.9'W Bay Boulevard Seaside Heights, NJ
TABLE 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 4
^
.17.
Isla'nd Beach Pier WC 68 Lat. 390 47.I'N
,. State Park
' (Sedge Island)
Long. 740 05.9'W j.-
All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Racks hung with nylon'iine from existing structures so the bottom panels are close to, but not touching the bottom. Racks at Forked River t
railroad bridge and Oyster Creek railroad bridge suspended with wire rope.
' Wb = Woodward-Clyde
/ WFCL = William F. Clapp Laboratories l
Site 4-A installed April,1977.
i Sites 10A,10B ins' alled April,1978.
t Site 16 discontinued November,1981.
Site 16A installed December,1981 - discontinued June,1982.
Site 16B installed June,1982.
8 l
TABLE 2. INCIDENCE OF TEREDINIDAE IN PANEL.S REMOVED NOVEMBER 7-8, 1983.
No of Percent Size Range Station Panet Specimens Filled in mm.
Species identification Remarks l
1 P
400 99 25 T_. navalis,375 Only 1 alive Teredinidae*
l C
42
<1
<1 42 Teredinidae*
2 P
1 3
255 1 Teredo spp.
C 0
5 P
1 6
355 1 B. gouldi C
0 7
P 4
20 170-330 4 B. gouldi C
0 8
P 3
10 75-265 3 B. gouldi 1 of 3 dead C
0 9
P 1
<1 4
1 B. gouldi C
0 10A P
2 5
55-290 1 B. gouldi, 1 Teredinidae*
I of 2 dead C
0 11 P
52 97 25-200 44 B. gouldi,8 T.
navalis
~
C 0
12 P
1 1
130 1 B_. gouldi C
0 13 P
18 75 110-340 17 B. gouldi, 1[navalis C
0 14 P
80 98 15-230 18 B. gouldi,62 62 dead Teredtntdae
- C 0
15 P
5 25 120-280 4 B. gouldi, 1 T. navalts C
0 16B P
1 3
220 1 B. gouldi C
0 17 P
17 12
<!-115 i B. gouldi; 10 T.
navalis; 6 Teredinidae*
C 5
<1
<1 Stations 3-4A,6,10, and ICB - No Teredinidae present.
P = Long-term panel submerged May 2-3, 1983.
C = Short-term panel submerged October 4-5, 1983.
- = Not speciated due to size or condition.
9 TABLE 3. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED DECEMBER 5-6,1983.
No. of Percent Size Range Strtion Panet Specimens Filled in mm.
Species Identification Remarks 1
P 400+
99 400 Teredinidae*
Only section 2"x4" received. Tubes broken. None alive.
C 60
<1
<1 60 Teredinidae*
5 P
5 35 180-410 5 B. gouldi C
0 7
P 7
18
<!-250 6 B. gouldi,1 Teredinidae
- C 0
8 P
10 60
<l-335 9 B. gouldi,1 1 B. gouldi dead Teredinidae
- C 0
10A P
4 25
<2-460 3 B. gouldi,1 Teredo spp.*
C 0
10B P
1 4
260 1 B. gouldi C
0 11 P
47 98 40-160 47 B. g C
0 12 P
3 12 15-400 3 B. gouldi idead C
0 13 P
18 90 95-230 18 B. gouldi 3 dead C
0 14 P
90 90
<l-170 40 B_. gouldi, 2 T.
navalis,48 Teredinidae*
C 0
15 P
7 8
<!-250 1 B_. gouldi, 3 T_.
navalis, 3 Teredinidae*
C 0
17 P
23 15
<l-160 15 T. navalis; 8 Teredinidae
- 1 dead C
0 Stations 2-4A,6,9-10, and 16B - No Teredinidae present.
P = Long-term panel submerged June 6-7, 1983.
C = Short-term panel submerged November 7-8, 1983.
o = Not speciated due to size or condition.
10 TABLE 4. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED JANUARY 9-10, 1984 f
No. of Percent Size Range St tion Panel Specimens Filled in mm.
Species Identification Remarks 1
P*
4001 99 4 T. navalis, 3961 Wood crumbling, Teredinidae *
- None alive C
0 2
P 1
2 160 1 T_. navalis C
0 5
P 2
<1
< !- l 2 Teredinidae*
- C 0
7 P
2 4
<!-220 1 B. gouldi, 1 Teredinidae*
- C 0
8 P
5 15 65-200 5g.gouldi C
0 10A P
1
<1 1
1 Teredinidae *
- C 0
11 P
16 50 11-260 13 p. gouldi, 3 C
0
-T. navalis 12 P
1 4
230 1 B. gouldi C
0 13 P
5 20 180-200 5g.gouldi C
0 14 P
36 35 90-240 36 g. gouldi C
0 15 P
3 8
140-230 3 T. navalis C
0 17 P
24 10 7-110 24 T_. navalis C
0 Stations 3-4A,6,9,10,10B, and 16B - No Teredinidae present.
P = Long-term panel submerged July 5-6, 1983.
C = Short-term panel submerged December 5-6, 1983.
- = Long-term panel removed November 7,1983 due to severity of attack.
- = Not speciated due to size or condition.
I1 TABLE 5. INCIDENCE OF LIMNORIA IN PANELS REMOVED NOVEMBER, DECEMBER,1983, AND JANUARY,1984 November December January No. of No. of No. of No. of No. of No. of StCtion Panel Tunnels Specimens Tunnels Specimens Tunswis Specimens 1
P O
O 0*
C 2
0 0
0 2
P 2400 2010 1500 800 280 165 C
2 2
0 0
3 P
80 70 27 15 4
0 C
0 0
0 4
P 610 510 3
2 2
1 C
0 0
0 4A P
7800 5000 6000 4500 3600 1500 C
1 0
0 0
Stations 5-17, no Limnoria present.
1 i
P = Long-term panel, submerged 6 months.
C = Short-term panel, submerged 1 month, o = Panel removed November 7,1983 due to severe teredinid attack.
12 TABLE 6. WATER QUALITY AT EXPOSURE PANEL STATIONS NOVEMBER,1983 Depth in Salinity Temperature O2 Station Date Time Feet 0/00 (OC)
(mg/1) pH 1
11/7/83 0902 7.5 27.5 9.4 10.0 8.0 2
11/7/83 0942 4.0 25.2 9.2 8.6 8.0 3
11/7/83 1017 2.0 24.2 9.2 8.2 3.0 4
11/7/83 1040 3.0 26.9 10.2 3.0 8.0 4A 11/7/83 1058 2.0 27.0 11.4 8.4 8.1 5
11/7/83 1118 2.0 21.2 10.5 8.2 7.9 6
11/7/83 1130 2.2 21.0 9.7 9.0 7.9 7
11/7/83 1153 4.0 25.8 12.2 8.6 8.0 8
11/7/83 1450 2.2 22.9 12.2 9.3 8.0 9
11/7/83 1335 7.0 24.5 13.2 7.7 7.9 10 11/8/83 1237 4.0 23.8 13.5 7.8 7.8 10A 11/7/83 1510 2.0 24.8 11.0 9.4 8.0 10B 11/7/83 1525 4.0 25.0 11.3 9.0 7.9 11 11/7/83 1537 2.0 22.0 11.0 9.7 8.0 12 11/3/83 1208 3.0 22.1 12.1 9.7 8.0 13 11/8/83 1132 3.0 22.6 12.2 8.6 8.0 14 11/8/83 1108 3.5 17.0 10.5 8.7 7.9 15 11/8/83 0847 35 21.0 9.7 9.9 8.0 16B 11/8/83 0915 4.5 17.5 9.5 9.4 8.I 17 11/3/83 1000 1.0 24.5 10.2 8.7 7.8 s
9
13 TABLE 7. WATER QUALITY AT EXPOSURE PANEL STATIONS DECEMBER,1983 Depth in S dinity Temperature O2 Station Date Titre Feet 0/00 (OC)
(mg/l) pH I
12/5/83 0905 9.0 29.1 9.0 9.2 8.1 2
12/5/83 0940 3.0 22.6 7.0 10.0 8.1 3
12/5/83 1012 3.0 24.2 6.6 10.2 8.1 4
12/5/83 1033 4.5 25.0 7.2 9.9 8.1 4A 12/5/83 1052 3.0 24.0 7.1 10.1 8.2 5
12/5/83 1109 3.0 20.8 7.8 10.0 8.0 6
12/5/83 1121 3.5 21.9 7.8 10.3 7.9 7
12/5/83 1136 2.5 15.1 8.0 11.0 7.3 8
12/5/83 1200 4.0 22.0 8.1 9.9 7.7 9
12/5/83 1222 5.5 21.1 9.1 7.8 7.0 10 12/5/83 1420 5.5 20.8 8.0 8.6 7.8 10A 12/5/83 1330 3.0 21.8 8.2 9.6 7.7 10B 12/5/83 1342 4.5 23.1 7.3 9.8 7.9 11 12/5/83 1400 3.0 21.2 7.3 9.6 8.I 12 12/5/83 1442 3.0 20.9 7.3 9.6 7.9 13 12/5/83 1505 3.0 20.8 6.8 9.3 7.9 14 12/5/83 1522 5.5 21.8 6.6 9.4 7.9 15 12/6/83 0850 4.5 17.9 7.3 10.6 7.7 16B 12/6/83 0920 5.5 14.0 7.I 11.I 7.6 17 12/6/83 0956 2.0 28.6 8.9 10.6 8.0 1
1 l
4
i 14 1
TABLE 8. WATER QUALITY AT EXPOSURE PANEL STATIONS 3ANUARY,1984 Depth in Salinity Temperature O2 Station Date Time Feet 0/00
( C)
(mg71) pH I
1/9/84 0910 7.0 23.1 0.3 11.4 8.2 2
1/9/84 0945 3.5 21.2 0.2 12.0 8.1 3
1/9/84 1025 1.0 20.5 0.5 11.4 8.1 4
1/9/84 1055 3.0 24.9 1.2 11.6 8.2 4A 1/9/84 1115 1.5 23.1 2.0 11.4 8.1 5
1/9/84 1130 1.0 14.0 1.2 12.0 7.6 6
1/9/84 1150 1.3 14.1 0.7 11.6 7.3 7
1/9/84 1204 3.0 24.2 3.0 11.2 8.2 8
1/9/84 1225 2.0 22.4 3.0 10.8 8.2 9
1/9/84 1355 6.0 23.8 4.0 9.4
- 7.8 10 1/9/84 1526 3.5 19.9 3.3 10.7 7.8 10A 1/9/84 1438 0.8 19.0 3.3 10.9 7.5 10B 1/9/84 1458 3.0 20.2 3.3 10.4 7.6 11 1/9/84 1510 1.0 17.6 2.3 11.6 7.9 12 1/9/84 1601 1.8 11.3 2.8 11.6 7.3 13 1/10/84 1128 2.0 9.8 5.3 13.0 7.4 14 1/10/84 1110 2.5 10.0 3.5 12.2 7.5 15 1/10/84 0858 3.0 15.0 2.4 12.8 7.5 16B 1/10/84 0935 3.5 17.2 4.2 9.4 7.4 17 1/10/84 1012 0.8 16.8 4.1 5.0 7.1
- Changed DO meters af ter Station 9. Air bubble under membrane.
l 15 TABLE 9. CONDITION OF GONADS OF TEREDIN!D BORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM OCTOBER THROUGH DECEMBER,1983 EA=Early active; LA= Late active; R= Ripe; PS= Partially spawned; S= Spent; M: Male; F= Female; H= Hermaphrodite
=
Month No. Months Gonad Specimen No.
Setion Renweed Exposed Species Sex Condition Comments 1281 14 Oct 83 4
Teredo navalis F
R 1282 6
Oct 83 6
Bankia gouldi No discernable gonad 1283 a 14 Oct 83 6
Bankia gouldi F
S b
Bankia gouldi M
PS c
Bankia gouldi M
S d
Bankia gouldi F
S e
Bankia gouldi M
S f
Bankia gouldi F
S g
Bankia gouldi F
S h
Bankia gouldi F
S i
Bankia gouldi F
S j
Bankia gouldi F
S k
Bankia gouldi M
EA 1
Bankia gouldi F
S m
Bankia gouldi M
EA n
Bankia gouldi F
S o
Bankia Rouldi F
S p
Bankia gouldi F
S 1284 10B Oct 83 6
Bankia gouldi F
S 1285 a 8
Oct 83 6
Bankia gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi F
S 1286 a 13 Oct 83 6
Bankia gouldi M
PS b
Bankia gouldi M
S c
Han W gouldi M
PS d
Bankia gouldi F
S e
Bankia gouldi F
PS f
Bankia gouldi F
S g
Bankia gouldi F
S h
Bankia gouldi F
S i
Bankia gouldi F
S j
Bankia gouldi M
S k
Bank:a gouldi F
S 1
Bankia gouldi M
S m
Bankia gouldi M
S n
Bankia gouldi F
S o
Bankia gouldi F
S p
Bankia gouldi F
S q
Bankia gouldi M
S r
Bankia touldi F
S 1287 a 17 Oct 83 6
Teredo navalis No discernable gonad b
Teredo navalis No discernable gonad c
Teredo navalis F
S d
Teredo navalis F
S e
Teredo navalis F
S f
Teredo navalis M
S 1288 17 Oct 83 6
Bankia gouldi F
S 1289 12 Oct 83 6
Bankla gouldi F
S 1290 13 Oct 83 6
Bankia gouldi No discernable gonad
16 TABLE 9. (Continued)
Menth No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1291 a 7
Oct 83 6
Bankia gouldi M
S b
Bankia gouldi F
S c
Bankia gouldi M
S 1292 10A Oct 83 6
Bankia gouldi No discernable gonad 1293 a 11 Oct 83 6
Bankia gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi F
S d
Bankia gouldi M
S e
Bankia gouldi M
S f
Bankia gouldi M
S g
Bankia gouldi F
S h
Bankia gouldi M
S i
Bankia gouldi M
S j
Bankia gouldi F
S k
Bankia gouldi F
S 1
Bankia gouldi M
S 129ts a 17 Oct 83 12 Teredo navalis F
EA Special panel b
Teredo navahs N1 5
c Teredo navabs No discernable gonad d
Teredo navahs M
S Teredo navahs M
S e
f Teredo navahs M
S Teredo navahs No discernable gonad g
1295 a 17 Oct 83 12 Bankia gouldi M
S Special panel b
Bankia gouldi M
S c
Bankia gouldi M
S d
Bankia gouldt No discernable gonad 1296 a 11 Oct 83 12 Bankia gouldi M
S Special panel b
Bankia gouldi No discernable gonad c
Bankta gouldi M
S d
Bankia gouldi No discernable gonad e
Bankia gouldi No discernable gonad i
Bankia Rouldi No discernable gonad g
Bankia gouldi No discernable gonad 1297 7
Oct 33 7
Bankia gouldi M
S Special panel 1298 15 Nov 83 6
Teredo navalis F
R 1299 13 Nov 33 6
Teredo navalis H
S 1300 a 15 Nov 83 6
Bankia gouldi M
S No discernable gonad b
c Bankia gouldi M
S d
Bankia gouldi M
S
l 17 TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1301 a 13 Nov 83 6
Bankia gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi No discernable gonad d
Bankia gouldi F
S e
Bankia gould M
f Bankia gouldi M
S g
Bankia gouldi M
S h
Bankia gouldi M
S i
Bankia gouldi M
S j
Bankia gouldi M
S k
Bankia goulda M
S 1
Bankia gouldi M
S 1302 a 14 Nov 83 6
Bankia gouldi M
S b
Bankia goulda M
LA c
Bar.kia gouldi F
S d
Bankta gouldi M
S e
Bankia goulds F
S f
Bankia gouldt M
S g
Bankia gouldi F
S h
Bankia gouldi F
S i
Bankia gouldi F
S 1303 8
Nov 83 6
Bankia gouldi M
S Bankia gouldi M
S 1304 5
Nov 83 6
Sankia gouldi M
S 1305 10A Nov 83 6
Bankia gouldi M
S 1306 16B Nov 83 6
Bankia gouldi M
S 1307 12 Nov 83 6
Bankia gouldi M
PS 1308 a 11 Nov 83 ','
6 Bankia gouldi M
S b
Bankia gouldi M
S d
Bankia goulda M
c 4 '
Bankia gouldi M
S
,;,, l-Bankia gouldi M
LA e
'\\
f u
Bankia gouldi M
S g
tsankia gdi M
LA h
Bankia goulda M
LA i
Bankia gouldt M
S i
j Bankia gouldt M
S 1339 a 17 Nov 33 6
Teredo navalis M
EA b
Teredo navalis M
c Teredo navalis F
EA d
Teredo navalis F
R e
Teredo navalis H
S f
Teredo navalis M
LA g
Teredo navalis F
LA h
Teredo navalis F
PS
18 TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Frpnand Species Sex Condition Comments 1310 a Nov 83 6
Teredo navalis F
S b
Teredo navalis F
S 1311 a 7
Nov 83 6
Bankia gouldi No discernable gonad b
Bankia gouldi M
S c
Bankia gouldi No discernable gonad d
Bankia gouldi No discernable gonad 1312 a 17 Nov 83 Bankia gouldi M
S Special panel b
Bankia gouldi F
S l
1313 2
Nov 83 6
Teredo spp.
F S
1314 a 17 Nov 83 12 Teredo navalis M
EA Special panel l
b Teredo navalis F
EA l
c Teredo navalis M
LA l
d Teredo navalis M
EA e
Teredo navalis F
LA f
Terado navalis F
LA
(
g Teredo navalis H
LA h
Teredo navalis M
S l
1 Teredo navalis M
EA j
Teredo navalis F
EA k
Teredo navalis F
S 1
Teredo navalis M
EA m
Teredo navalis F
LA n
Teredo r.avalis M
EA j
o Teredo navalis M
EA 1313 17 Nov 83 6
Bankla gouldi M
S
(
1316 i
Nov 83 6
Teredo navalis M
S I
l 1317 12 Nov 83 12 Bankia gouldi M
S Special panel 1
1318 a 7
Nov 83 12 Bankia gouldi M
S Special panel b
Bankia gouldi No discernable gonad 1319 a 11 Nov 83 12 Bankia gouldi Special panel; no
[
discernable gonad b
Bankia gouldi No discernable gonad e
Bankia gouldi No discernable gonad d
M gouldi No discernable gonad e
Bankia gouldi No discernable gonad i
Bankia gouldi No discernable gonad g
Bankia gouldi M
S h
Bankia gouldi No discernable gonad i
Bankia Louldi M
S j
Bankia gould I M
PS k
Bankia gould.
M S
1 Bankia gould..
M S
l l
l 19 l
TABLE 9. (Continued) l Month No. Months Goned Specimen No.
Station Removed Fwpnmed Species Sex Condition Comments 1320 a 17 Dec 83 6
Teredo navalis M
PS b
Teredo navalis H
LA c
Teredo navahs H
LA d
Teredo navalis F
PS e
Teredo navalis M
LA f
Teredo navalis F
LA g
Teredo navalis H
S h
Teredo navahs F
LA 1321 a 14 Dec 83 6
Bankia gouldi M
S b
Bankia gouldi F
EA c
Bankia gouldi M
EA d
Bankia gouldi F
S e
Bankia goug M
EA f
Bankia gouldi M
EA g
Bankia gouldi M
EA h
Bankta gouldi M
EA a
Bankia kouldi M
EA j
Bankia gouldi M
S k
Bankia gouldi M
EA 1
Bankia Louldi F
S m
Bankia gouldi F
S n
Bankia Louldi' M
S o
Bankia gouldi M
S 1322 13 Dec 83 6
Bankia gouldi M
S 1323 a 13 Dec 83 6
Teredo navalis F
PS b
Teredo navalis No discernable gonad c
Teredo navalis M
LA 1324 a 14 Dec 83 6
Teredo navalis F
PS b
Teredo navahs F
PS 1323 a 13 Dec 83 6
Bankia gouldi M
S b
Bankia gouldi M
EA e
Bankia gouldi M
S d
Bankia gouldi F
EA e
Bankia gouldi No discernable gonad f
Bankia gouldi F
EA l
g Bankia gould F
EA h
Bankia gouldi F
S i
Bankia gould F
)
Bankia gouldi F
S k
Bankia goulds M
EA 1
Bankia gouldi F
S m
Bankia gouldi M
S n
Bankia gouldi M
S o
Bankia gouldi M
S 1326 12 Dec 83 6
Bankia M M
EA 1327 a 12 Dec 83 6
Bankla gouldi M
S b
Bankia M No discernable gonad
20 TABLE 9. (Continued)
Month No, Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1328 a 8
Dec 83 6
Bankia gouldi M
S b
3ankia gouldi M
S c
Bankia gouldi M
5 d
Bankia gouldi M
S e
Bankia gouldi No discernable gone.d f
Bankia gouldi M
S g
Bankia gouldi No discernable gonad h
Bankia gouldi M
S 1329 a 7
Dec 83 6
Bankia gouldi F
S b
Bankia gouldi No discernable gonad c
Bankia gouldi No discernable gonad d
Bankia gouldi e
Bankia gouldi No discernable gonad 1330 7
Dec 83 12 Bankia gouldi Special panel; no discernable gonad 1331 10B Dec 83 6
Bankia gouldi No discernable gonad 1332 a 12 Dec 83 12 Bankia gouldi F
S Special panel b
Bankia gouldi No discernable gonad 1333 a 10A Dec 8 3 6
Bankia gouldi No discernable gonad b
Bankia gouldi M
S c
Bankia gouldi No discernable gonad 1334 a 17 Dec 83 12 Bankia gouldi Special panel; no discernable gonad b
Bankia gouldi F
EA 1333 a 17 Dec 83 12 Teredo navalis M
EA Special panel b
Teredo navalis F
S c
Teredo navalis M
EA d
Teredo navalis M
S e
Teredo navalis H
S f
Teredo navalis H
S g
Teredo navalis H
S h
Teredo navalis F
PS i
Teredo navalis M
LA j
Teredo navalis M
LA k
Teredo navalis M
LA 1
Teredo navalis M
LA m
Teredo navalis F
EA n
Teredo navalis M
LA o
Teredo navalis M
EA l
21 TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1336 a 11 Dec 83 6
Bankia gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi M
S d
Bankia gouldi M
S e
Bankia gouldi M
S f
Bankia gouldi M
S Bankia gouldi No discernable gonad h
Bankia gouldi M
S i
Bankia gouldi M
S i
Bankia goulds M
S k
Bankia gouldi F
S 1
Bankia gouldi F
S m
Bankia gou!di F
S n
Bankia gouldi M
S 1337 a 3
Dec 83 6
Bankia gouldi No discernable gonad b
Bankia gouldi No discernable gonad c
Bankia goulds No discernable gonad d
Bankia gouldi F
S e
Bankia gouldi No discernable gonad 1338 a 11 Dec 83 12 Bankia gouldi M
S Special panel j
b Bankia gouldi No discernable gonad I
c Bankia gouldi No discernable gonad d
Bankia gould No discernable gonad e
Bankia gouldi No discernable gonad i
Bankia gouldi No discernable gonad l
l 1
s a
t Batielle New England Marine Research Laboratory 397 Washington Street Duxbury, Massachusetts 02332 Telephone (617) 934-5682