u:ug%
UNITED STATES j-NUCLEAR REGULATORY COMMISSION Ef WASHINGTON, D.C. 2056M001 s., *... /
CAROLINA POWER & LIGHT COMPANY. et al.
I DOCKET NO. 50-325 BRUNSWICK STEAM ELECTRIC PLANT. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.178 License No. OPR-71 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment filed by Carolina Power & Light Company (the licensee), dated January 25, 1993, as supplemented December 28, 1993, September 13, 1994, January 13, 1995, and May 25, 1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating Licenst No.
DPR-71 is hereby amended to read as follows:
9508170124 950811 PDR ADOCK 05000324 P
4 i
.i (2)
Technical Soecifications The Technical Specifications contained in Appendices A and.B, as-revised through Amendment No. 178, are hereby' incorporated in-the license. Carolina. Power & Light Company shall operate the facility in accordance with the Technical Specifications.
')
3.
This license amendment is effective as of the date of its issuance and-shall be implemented within 60-days of issuance.
FOR THE NUCLEAR REGULATORY C0l#11SSION l
w( tb h
- .__[vk 37W f
t 1 g David B. Matthews, Director I
Project Directorate II-I i
Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation l
hang o the Technical Specifications Date of Issuance:
August 11, 1995 i
[
4 i
.~.I
l ATTACHMENT TO LICENSE AMENDMENT NO,178 FACILITY OPERATING LICENSE NO. DPR-71 DOCKET NO. 50-325 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages. The revised areas are indicated by marginal lines.
Remove Paoes Insert Paoes 3/4 1-4 3/4 1-4 8 3/4 1-2 B 3/4 1-2 B 3/4 1-2a l.
REACTIVITY CONTROL SYSTEMS LIMITING CONDITION'FOR OPERATION (Continued)
ACTION:.(Continued) 2.
If the inoperable control rod (s) is inserted:
a)
Within one' hour disarm the associated directional control valves either:
1)
Electrically, or Hydraulically by.'closin water isolation valves.g the drive water and exhaust 2)
~
b)
Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
3.
The provisions of Specification 3.0.4 are not applicable.
I
^
c.
With more than 8 control rods inoperable, be in at least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SURVEILLANCE REQUIREMENTS 4.1.3.1.1 The scram discharge volume drain and vent valves shall be demonstrated OPERABLE at least once per 31 days by:*
a.
Verifying each valve to be open.
b.
Cycling each valve at least.one complete cycle of full travel.
4.1.3.1.2 All withdrawn control rods not required to have their directional control valves disarmed electrically or hydraulically shall be demonstrated OPERABLE by moving each control rod at least one notch:
i a.
At least once per 7 days when above the preset power level of the j
RWH and b.
At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when above the preset power level of the RWH and any control rod is innovable as a result of excessive friction or mechanical interference.
i 4.1.3.1.3 All withdrawn control rods shall be determined OPERABLE by demonstrating the scram discharge volume drain and vent valves OPERABLE. when the reactor protection system logic is tested per Specification 4.3.1.2. by verifying that the drain and vent valves:
a.
Close within 30 seconds after receipt of a signal for control rods to scram. and b.
Open when the scram signal is reset or the scram discharge volume trip is bypassed.
]
These valves may be closed intermittently for testing under administrative control.
BRUNSWICK - UNIT 1 3/4 1-4 Amendment No. 178 1
l l
REACTTVITY CONTROL SYSTEMS BASES 1
CONTROL RODS (Continued) potential effects of the rod ejection accident are limited.
The ACTION statements permit variations from the basic requirements but at the same time impose more restrictive criteria for continued operation.
A limitation on inoperable rods is set such that the resultant effect on total rod worth and scram shape will be kept to a minimum. The requirements for the various scram time measurements ensure that any indication of systematic problems with rod drives will be investigated on a timely basis.
Damage within the control rod [ drive mechanism could be a generic problem: therefore, with a control rod immovable because of excessive friction
~
or mechanical interference, operation of the reactor is limited to a time period which is reasonable to determine the cause of the inoperability and at
~
the same time prevent operation with a large number of inoperable control rods.
Control rods that are inoperable for other reasons are permitted to be taken out of service 3rovided tlat those in the non-fully-inserted position are consistent with tie SHUTDOWN MARGIN requirements.
With one or more withdrawn control rods inoperable for reasons other than being stuck, operation may continue provided within one hour, either a) the inoperable withdrawn control rod (s) are fully inserted and disarmed (electrically or hydraulically), or b) the inoperable control rod (s) are separated from other inoperable control rods by at least two control cells in all directions. and the insertion capability of each inoperable control rod is demonstrated by inserting the control rod at least one notch t'y drive water pressure within the normal operating range.
Inserting a control rod ensures the shutdown and scram capabilities are not adversely affected. Adequate separation of inoperable withdrawn control rods (inoperable for reasons other than being immoveable or untrippable) is required to ensure consistency with the scram reactivity function assumed in the reload licensing analysis.
Inserted inoperable control rods are disarmed to prevent inadvertent withdrawal during subsequent operations. The control rods can be hydraulically disarmed by closing the drive and exhaust water isolation valves or electrically disarmed by disconnecting power from all four directional control valve solenoids.
Technical Specification 3.1.3.1. ACTION b is generic to the other control rod Technical Specifications 3.1.3.2. 3.1.3.4. 3.1.3.5. 3.1.3.6 and 3.1.3.7. which identify individual types of control rod inoperability.
Each of the individual control rod Technical Specifications identifies that the provisions of Technical Specification 3.0.4 are not applicable provided the specification ACTIONS are satisfied. the affected control rod is declared inoperable, and the requirements of Technical Specification 3.1.3.1 are satisfied.
Inclusion of an exemption from the requirements of Technical f
Specification 3.0.4 in Specification 3.1.3.1. ACTION b allows changing from 0)ERATIONAL CONDITION 2 to OPERATIONAL CONDITION 1 with inoperable control rods and is consistent with the individual control rod operability specifications listed above (Reference 8).
BRUNSWICK - UNIT 1 B 3/4 1-2 Amendment No.178 l
REACTIVITY CONTROL SYSTEMS BASES CONTROL RODS (Continued)
The number of control rods permitted to be inoperable could be more than the eight allowed by the specification, but the occurrence of eight ino>erable rods could be indicative of a generic problem and the reactor must be slut down for investigation and resolution of the problem.
The control rod system is analyzed'to bring the reactor subcritical at a rate fast enough to prevent the HPCR from becoming less than the Safety Limit l
HCPR of Specification 2.1.2 during the limiting power transient analyzed in Section 14.3 of the FSAR.
This analysis shows that the negative reactivity rates resulting from the scram with the average response of all the drives as given in the specifications, provide the required protection and MCPR remains greater than t1e Safety Limit MCPR of Specification 2.1.2 The occurrence of scram times longer than those specified should be viewed as an indication of a systemic problem with the rod drives and. therefore. the surveillance interval is reduced in order to prevent operation of the reactor for long periods of time with a potentially serious problem.
Control rods with inoperable accumulators are declared inoperable and Specification 3.1.3.1 then applies. This prevents a pattern of inoperable accumulators that would result in less reactivity insertion i
BRUNSWICK - UNIT 1 B 3/4 1-2a Amendnent No. 178 l
.k i
@ Lttg, 2
_ k UNITED STATES
?
o
' NUCLEAR REGULATORY COMMISSION f
WASHINGTON, D.C. 20066 4 001 g
/
CAROLINA POWER & LIGHT COMPANY. et al.
DOCKET NO. 50-324.
BRUNSWICK STEAM ELECTRIC PLANT. UNIT 2
[
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 209 License No. DPR-62 t
1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment filed by Carolina Power & Light Company (the licensee), dated January 25, 1993, as supplemented i
December 28, 1993, September. 13, 1994, January 13, 1995, and May 25, 1995, complies with the standards and. requirements of the i
Atomic. Energy Act of 1954, as. amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; j
B.
The facility will operate in conformity with the application, the I
provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (1) that the activities autho' rized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations;
- i D.
The issuance of this amendment will not be iniatical to the common defense and security or to the health and safety'of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No. DPR-62 is hereby
- amended to read as follows:
.S m.
tt r
- t--
4 t
(2)
Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 209, are hereby incorporated in the license.
Carolina Power & Light Company shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance and shall be implemented within 60 days of issuance.
FOR THE NUCLEAR REGULATORY COM ISSION l
w(4
.>LSht tfd t
' [ David B. Matthews, Director
-jk Project Directorate 11-1 1
/
Division of Reactor Projects - I/II j
Office of Nuclear Reactor Regulation i
Attachment:
Changes to the Technical I
Specifications
-l l
Date of Issuance:
August 11, 1995
]
O
i ATTACHMENT TO LICENSE AMENDMENT NO. 209 FACILITY OPERATING LICENSE NO. OPR-62 DOCKET NO. 50-324 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.
The revised areas are indicated by marginal lines.
-Remove Paaes Insert Paaes 3/4 1-4 3/4 1-4 B 3/4 1-2 B 3/4 1-2 B 3/4 1-2a 4'
i
REACTIVITY CONTROL SYSTEMS LIMITING CONDITION'FOR OPERATION (Continued)
ACTION:
(Continued) 2.
If the inoperable control rod (s) is inserted; a)
Within one hour disarm the associated directional control valves either:
1)
Electrically, or,
2)
Hydraulically by closing the drive water and exhaust water isolation valves.
b)
Otherwise. be in 5t least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
~
3.
The provisions of Specification 3.0.4 are not applicable.
c.
With more than 8 control rods inoperable, be in at least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.1.3.1.1 The scram discharge volume drain and vent valves shall be demonstrated OPERABLE at least once per 31 days by:*
a.
Verifying each valve to be open.
b.
Cycling each valve at least one complete cycle of full travel.
4.1.3.1.2 All withdrawn control rods not required to have their directional control valves disarmed electrically or hydraulically shall be demonstrated OPERABLE by moving each control rod at least one notch:
a.
At least once per 7 days when above the preset power level of the RWM and b.
At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when above the preset power level of the RWM and any control rod is immovable as a result of excessive friction or mechanical interference.
4.1.3.1.3 All withdrawn control rods shall be determined OPERABLE by demonstrating the scram discharge volume drain and vent valves OPERABLE, when the reactor protection system logic is tested per Specification 4.3.1.2. by verifying that the drain and vent valves:
a.
Close within 30 seconds after receipt of a signal for control rods to scram, and b.
Open when the scram signal is reset or the scram discharge volume trip is bypassed.
i l
These valves may be closed intermittently for testing under administrative control.
BRUNSWICK - UNIT 2 3/4 1-4 Anendment No. 209 l
REACTIVITY CONTROL SYSTEMS BASES CONTROL RODS (Continued) potential effects of the rod ejection accident are limited.
The ACTION statements permit variations from the basic requirements but at the same time impose more restrictive criteria for continued operation.
A limitation on inoperable rods is set such that the resultant effect on total rod worth and scram shape will be kept to a minimum.
The requirements for the various scram time measurements ensure that any indication of systematic problems with rod drives will be investigated on a timely basis.
Damage within the control rod.. drive mechanism could be a generic problem: therefore, with a control rod immovable because of excessive friction or mechanical interference, operation of the reactor is limited to a time period which is reasonable to determine-the cause of the inoperability and at the same time prevent operation with a-large number of inoperable control rods.
Control rods that are ino]erable for other reasons are permitted to be taken out of service provided tlat those in the non-fully-inserted position i
are consistent with t1e SHUTDOWN MARGIN requirements.
1.
With one or more withdrawn control rods inoperable for reasons other than being stuck, operation may continue provided within one hour either a) the inoperable withdrawn control rod (s) are fully inserted and disarmed (electrically or hydraulically), or b) the inoperable control rod (s) are j
separated from other inoperable control rods by at least two control cells in all directions, and the insertion capability of each inoperable control rod is demonstrated by inserting the control rod at least one notch by drive water pressure within the normal operating range.
Inserting a control rod ensures the shutdown and scram capabilities are not adversely affected. Adequate separation of inoperable withdrawn control rods (inoperable for reasons other than being immoveable or untrippable) is required to ensure consistency with the scram reactivity function assumed in the reload licensing analysis.
Inserted inoperable control rods are disarmed to prevent inadvertent withdrawal during subsequent operations.
The control rods can be hydraulically disarmed by closing the drive and exhaust water isolation valves. or electrically disarmed by disconnecting power from all four directional control valve solenoids.
Technical Specification 3.1.3.1. ACTION b is generic to the other control rod Technical Specifications 3.1.3.2. 3.1.3.4. 3.1.3.5. 3.1.3.6. and 3.1.3.7. which identify individual types of control rod inoperability.
Each of the individual control rod Technical Specifications identifies that the provisions of Technical Specification 3.0.4 are not applicable provided the specification ACTIONS are satisfied. the affected control rod is declared inoperable, and the requirements of Technical Specification 3.1.3.1 are satisfied.
Inclusion of an exemption from the requirements of Technical Specification 3.0.4 in Specification 3.1.3.1. ACTION b. allows changing from OPERATIONAL CONDITION 2 to OPERATIONAL CONDITION 1 with inoperable control rods and is consistent with the individual control rod operability specifications listed above (Reference 8).
BRUNSWICK - UNIT 2 B 3/4 1-2 Amendment No. 209 l
REACTfVTTY CONTROL SYSTEMS BASES CONTROL RODS (Continued)
The number of control rods permitted to be inoperable could be more than the eight allowed by the specification. but the occurrence of eight inowrable rods could be indicative of a generic problem and the reactor must be slut down for investigation and resolution of the problem.
The control rod system is analyzed to bring the reactor subcritical at a rate fast enough to prevent the MPCR from becoming less than the Safety Limit MCPR of Specification 2.1.2 during th.e limiting )ower transient analyzed in Section 14.3 of the FSAR. This analysis shows tlat the negative reactivity rates resulting from the scram with the average response of all the drives as given ir. toe specifications, provide the required protection and MCPR remains greater than t1e Safety Limit MCPR of Specification 2.1.2 The occurrence of scram times longer than those specified should be viewed as an indication of a systemic problem with the rod drives and. therefore the surveillance interval is reduced in order to prevent operation of the reactor for long periods of time with a potentially serious problem.
Control rods with inoperable accumulators are declared inoperable and Specification 3.1.3.1 then applies. This prevents a pattern of inoperable accumulators that would result in less reactivity insertion BRUNSWICK - UNIT 2 B 3/4 1-2a AmendmentNo.209l