r;'

y VIRGINIA ELECTRIC AND TOWER COMPANY RIcnwown', VIRGINIA 202 61 August 2, 1995' U.S. Nuclear Regulatory Commission Serial No.95-316 Attention: Document Control Desk NL&P/EJW

~ Washi~ don, D.O. 20555 Docket No.

50-339 License No.

NPF-7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 2 1995 STEAM GENERATOR REPLACEMENT / REFUELING OUTAGE INSERVICE INSPECTION

SUMMARY

REPORT Pursuant to the provisions of ASME Section XI, Virginia Electric and Power Company i

hereby submits the enclosed. Inservice Inspection Report for the North Anna Power Station Unit 21995 Steam Generator Replacement / Refueling outage. This report is a summary of examinations performed during the outage for the second period of the North Anna Unit 2 second ten-year inservice inspection interval. The report consists of three attachments.

The first attachment, Form NIS-1, Owner's Report for Inse u Inspections, and the

)

second attachment, Form NIS-2, Owner's Report of Repa!

Replacement and the associated summaries, are provided pursuant to IWA-6220 of the 1986 Edition of ASME Section XI. Attachment 3 provides an evaluation analysis for two components found to exceed the acceptance standards of IWF-3410 but which were determined to be acceptable without repair.

If you have any further questions, please contact us.

Very truly yours, James P. O'Hanlon Sonior Vice President - Nuclear Attachments: -

Owner's Report for laservice Inspections -

Owner's Report of Repairs and Replacements -

Evaluation Analysis of Examination and Results 0

9509090201 050909 PDR ADDCK 0500o539

[

[

U PDR i

m

/

-L cc:

U.S. Nuclear 'legulatory Commission Region 11 101 Marietta Street, N.W.

Suite 2900 Atlanta, Georgia 30323 Mr. R. D. McWhorter NRC Senior Resident inspector North Anna Power Station r

J f

6 i

i 4