ML20087B392

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Rept 50-219/83-25.Corrective Actions:Chemistry Surveillance Test Program Revised to Ensure That Chemistry Surveillances Listed & Completed as Scheduled
ML20087B392
Person / Time
Site: Oyster Creek
Issue date: 01/27/1984
From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20087B389 List:
References
NUDOCS 8403090073
Download: ML20087B392 (2)


Text

_ _ - _ _ _ _ _.

l e

t GPU Nuclear Corporation

- Nuclear

= g r 388 Forked River, New Jersey 08731-0388 609 971-4000 Writers Direct Dial Number

January 27, 1984 Mr. %cmas T. Martin, Director Division of Engineering and Technical Programs U.S. Nuclear Regulatory Commission Region 1 631 Park Avenue King of Prussia, PA 19406

Dear Mr. Martin:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Inspection Report 83-25 Wis letter is submitted in response to your letter of December 28, 1983, regarding the Notice of Violation (t m ) contained in Appendix A.

In accordance with 10 CFR 2.201, the attachment to this letter represents our reply to the tm.

If there are any questions regarding the information therein, please contact me or Mr. Michael Laggart of my staff at (609)971-4643.

Very truly yours, ne _ -

A y yf-a)' J Pethr %. Fiecler Vice President and Director Oyster Creek PBF:PFC: dam

' Attachment cc: Dr. W omas E. Murley, Administrator Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 NRC Resident Inspector Oyster Creek Nuclear Generating Station Forked River, NJ 08731 8403090073 840305 PDR ADOCK 05000219 O

PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation

n

[.;

.,t.

.o

[

s ATTACHMENT i-L Violation:

. Technical Specification 4.6.B.2.C requirec, in part, that a monthly proportional cmposite sample of each lig. tid effluent discharge batch be

. analyzed for tritium.

. Contrary to the above, no monthly proportional composite sample for liquid effluent discharge batch 58-82, released on August 22, 1982, was analyzed for tritium. Also, no tritium assay was conducted on samples from the two liquid effluent discharge batches released during March 1982.

Wis is a Severity Iavel V violation'(Supplement IV).

' Reply:

We concur ith the violation as stated A review of all Chemistry-related surveillances required by Appendix A Technical Specifications was performed for the period January 1982 through September 1983.. No discrepancies in effluent records during the period in question were identified in addition to those already indicated in the Notice of Violation.

Procedure No. 832.1, "Chomistry Surveillance Test Program", was reviewed for coupleteness. Revisions to the above procedure ensure that all Appendix A Technical Specification Chemistry surveillances are listed and coupleted as scheduled. Specifically, weekly review of surveillances and

. sign-off documentation is now required by Procedure No. 832.1.

Supervisor awareness has been increased by the weekly surveillance follow-up and sign-off requirement. Furthermore, periodic in-depth review by an independent staff member is also conducted.

' he corrective steps discussed above have been taken to prevent a recurrence of this type.

Ee. data review was completed on October 26, 1983. We procedure was revised and full implementation was achieved on November 21, 1983.

i si r

_ _ _ _