Download: ML20086U301 (2)


Text

??

4 Ngy k

t..

300 Madhon Avenue

.hihn P. siser loisdo, OH 43652-0001 Vice President. Nuclear 419-249-23M gg I

b; A

Docket Number 50-346 License Number NPF-3 7

Serial Number 2305 i

[.

July 28, 1995 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555

Subject:

Proposed Modification to Davis-Besse Nuclear Power ' '

on (DBNPS) Technical Specifications 3/4.8.1.1 - A.C.

Sour-ces - Operating,'3/4.8.1.2 - A.C. Sources - Shutdown, and q

their Associated Bases, and Bases 3.0.5.

ladies and Gentlemen:

Enclosed is an application for an amendment to the DBNPS Unit Number 1 Operating License NPF-3, Appendix A, Technical Specifications. The pro-posed changes involve Technical Specification (TS) 3/4.8.1.1 - A.C. Power Sources - Operating, TS 3/4.8.1.2 - A.C. Sources - Shutdown, and their associated Bases, and Bases 3.0.5.

Specifically, the proposed revisions: clarify the Limiting Condition for Operation for TS 3.8.1.1 and 3.8.1.2 from " independent" circuit to " qual-ified" circuit; explain in the Bases the requirements for operability of an offsite circuit; delete the STAGGERED TEST BASIS ccheduling require-ment to perform Emergency Diesel Generator surveillances; explain in the Bases an acceptable method for verification of Emergency Diesel Generator speed for sut:veillance requirements (SR) 4.8.1.1.2.a.4 and 4.8.1.1.2.c.4; remove a burveillance test extension that has expired for SR 4.8.1.1.1.b; and add an1 exception for SR 4.8.1.1.2.c.5 and 4.8.1.1.2.c.7 to SR 4.8.1.2.

A revision is also proposed to Bases 3.0.5 to ref1cet the clarification from " independent" circuit to " qualified" circuit.

O J 0 0 0.,'

950B040043 950729 PDR ADOCK 05000346 p_

PDR A00 I operating companies Cleveland Electnc tiluminatinD Toledo Edison Il[

l

m--

N'

?Do'cket Number 50-346'

.Licenzo Number NPF-3 r;

Serial Number 2305

,Page 2 i

Toledo Edison requests that the NRC approve and issue this change by j

February 7, 1996.

Should you have any questions or require additional information, please contact Mr. Villiam T. O'Connor, Manager - Regulatory Affairs, at (419) 249-2366.

Very truly yours, l

DHL/laj Enclosure i

cc:

L. L.'Gundrum, DB-1 NRC/NRR Project Manager H. J. Miller, Regional Administrator, NRC Region III S. Stasek, DB-1 NRC Senior Resident Inspector J. R. Villiams, Chief of Staff, Ohio Emergency Management Agency, State of Ohio (NRC Liaison) j!

Utility Radiological Safety Board