O O

Vepco s

/ y>

wac.ima e.scrme.o,o#cosacoser.,

Surry Power Station P.O. nox 315 Surry Virginia 23883 necember 31, 1974 Director of Regulatory Operations 230 Peachtree Suite 818 Atlanta, Georgia 30303 This is to inform you by telecopy within twenty-four (24) hours of an Abnorma! Occurrer.cc that was noted on December 30, 1974, at Surry Nuclear Power Station.

A crack was found in the body of a Unit 2 containment spray.ctneck valve.

Subsequent investigation has revealed rockshaft cracks in five other containment spray and recirculation spray check valves.

The Unit 2 containment spray check valve and aII cracked rockshafts are being replaced.

f.5 h E. M. Sweeney, Jr.

Station Manager

\\