ML20086N255

From kanterella
Jump to navigation Jump to search
Proposed TS 5.2.1, Fuel Assemblies, Allowing Use of Cladding Matls Other than Zircaloy or ZIRLO W/Approved Temporary Exemption to 10CFR50.46,10CFR50.44 & 10CFR50,App K & Allowing Use of Lead Fuel Assemblies
ML20086N255
Person / Time
Site: Calvert Cliffs  
Issue date: 07/13/1995
From:
BALTIMORE GAS & ELECTRIC CO.
To:
Shared Package
ML19325F616 List:
References
NUDOCS 9507250156
Download: ML20086N255 (4)


Text

,

ATTACHMENT (1) l J

UNIT I TECIINICAL SPECIFICATIONS MARKED-UP PAGE 5-1 9507250156 950713 PDR ADOCK 05000317 P

PDR

5.0 DESIGN FEAT 11RES 5.1 SITE LOCATION The site for the Calvert Cliffs Nuclear Power Plant is. located on the western shore of the Chesapeake Bay in Calvert County, Maryland, about 10-1/2 miles southeast of Prince Frederick, Maryland. The site is approximately 45 miles southwest of Washington, DC, and 60 miles south of Baltimore, Maryland. The exclusion area boundary has a minimum radius of 1,150 meters from the center of the plant.

5.2 REACTOR CORE 5.2.1 FUEL ASSEMBLIES The reactor shall contain 217 fuel assemblies. Each assembly shall consist of a matrix of cylindrical zircaloy or ZIRLO cladding fuel rods with an initial composition of natural or slightly enriched uranium dioxide (UO,)

as fuel material.

Limited substitutions of zirconium alloy or stainless steel filler rods for fuel rods, in accordance with approved applications of fuel rod configurations, may be used.

Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC staff approved codes and methods and shown by tests or analyses to comply with all fuel safety design bases. A limited number of lead test assemblies that have not completed representative testing may be placed in nonlimiting regions. 4 5.2.2 CONTROL ELEMENT ASSEMBLIES The reactor core shall contain 77 full length and no part length control elenent assemblies.

1 5.3 FUEL STORAGE 5.3.1 CRITICALITY 5.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a.

Fuel assemblies having a maximum U-235 enrichment of 4.52 weight percent; b.

k,,,5 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.7.2 of the UFSAR; c.

A nominal 10-3/32-inch center-to-center distance between fuel assemblies.

g g(

clgdd, R7& beria h fY7ap N WY agoved e temp %

CALVERT CLIFFS - UNIT 1 5-1 Amendment No. -204-

ATTACHMENT (2) i f

UNIT 2 TECIINICAL SPECIFICATIONS MARKED-UP PAGE 5-1 l

1 1

5.0 DESIGN FEATURES 5.1 SITE LOCATION The site for the Calvert Cliffs Nuclear Power Plant is located on the western shore of the Chesapeake Bay in Calvert County, Maryland, about 10-1/2 miles southeast of Prince Frederick, Maryland. The site is approximately 45 miles southwest of Washington, DC, and 60 miles south of Baltimore, Maryland. The exclusion area boundary has a minimum radius of 1,150 meters from the center of the plant.

5.2 REACTOR CORE 5.2.1 FUEL ASSEMBLIES The reactor shall contain 217 fuel assemblies. Each assembly shall consist of a matrix of cylindrical zircaloy or ZIRLO cladding fuel rods with an initial composition of natural or slightly enriched uranium dioxide (UO,)

as fuel material.

Limited substitutions of zirconium alloy or stainless steel filler rods for fuel rods, in accordance with approved applications of fuel rod configurations, may be used.

Fuel assemblies shall be limited to those fuel designs that have been analyzed with applicable NRC staff roved codes and methods and shown by tests or analyses to comply with a

a

'uel safety design bases. A limited number of lead test assemblies t..

have not completed representative testing may be placed in non11miting regions. (

g 5.2.2 CONTROL ELEMENT ASSEMBLIES The reactor core shall contain 77 full length and no part length control element assemblies.

5.3 FUEL STORAGE 5.3.1 CRITICALITY 5.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

Fuel assemblies having a maximum U-235 enrichment of 4.52 weight a.

percent; b.

k,,, < 0.95 if fully flooded with unborated water, which includes an a'ilowance for uncertainties as described in Section 9.7.2 of the UFSAR; c.

A nominal 10-3/32-inch center-to-center distance between fuel assemblies.

MCed 4)Ah 9n

" /'

CALVERT CLIFFS - UNIT 2 5-1 Amendment No.-182-