MONTi!LY OPERATING REPORT BROWNS FERRY NUCLEAR PLANT TENNESSEE VALLEY AUT110RITY NOVEMBER 1991 DOCKET NUMBERS 50-259,--50-260, AND 50-296 LICENSE NUMBERS DPR-33, DPR-52, AND DPR-60

?

2112190140 911213 -

c'DR ADOCK 05000259 R PDR

, to . .

3,3. .. 3

-,p ,

i I

i a

OPERATIONAL,

SUMMARY

NOVEMBER 1991 UNIT 1 Unit remains on administrative hold to resolve various TVA and NRC concerns.

' UNIT 2 Unit 2 generated 800,200 MWHs (gross) electrical power and was on line 100 percent of.the reporting period.

UNIT 3 Unit remains on Edministrative hold to resolve various TVA and NRC concerna.

l l .-

0 7.', - ,

-AVERAGE DAILY UNIT POWER LEVEL DOCKET N0. 50-259 Unit One PREPARED.IlY S . . A uRat 1i f f_.

TELEPil0NE (205) 729-2932

- MONTil .. NOVEMBER 1991

- DAY. f.VERAGE DAILY POWER LEVEL. DAY -AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) l' -0 17 0 2 0 18 0 3 0 19 0 4 0 20 0 5 0 21 0 6' 0- 22 0

7. 0 23 0 8 -0 24 0 9 0 25 0 10- 0 26 9_

~

-11 0 27 0 12- 0 -

28 0

~13 0 29 0 14- 0 30 0 15 0 16 0

'0449k/8

- _ _ _ _ _ _ _ _ _ _ _ _ - ____ . _ . _ _ _ _ _ _ _ - _ _ _ _ - - _ _ . _ _ _ _ - _ ____-_ _ ___ __. __-m

1 l

e i

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-269 Unit Two PREPARED BY S. A. Ratlif.1_

TELEPHONE I2SJ) 729-2937 MONTl! NOVEMBER 1991 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 .1922__. 17 __

1092 2 1051 18 1088 3 1046 19 1100 4 1077 20 1110 5- 1098 21 1110 6- 1102' 22 1069 7 _ _ _ _

1093 23 1075 8 1107 24 1072 9 1098 25 1091 10_ 1091 ___ 26 1095

- 11 1085 27 1097

- 12 1084 28 1096 13 -- 1025 -29 1073 14 1073 30 1100 15' 1109-16 1062 0449k/9 l-1 -.

n .., , , , ,,m, 9

. : . .- s,

-AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-296 ,_

UNIT ..Three

^

PREPARED llY S. A. Ratliff TELEP110NE L205) 729-2937 MONTil NOVEMBER 1991 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWEP LEVEL (MWe-Net)_ (MWe-Net) 1- 0 17- 0 2 0 18 0-3 0 19 0 4 0 20 0 5 0 21 0 6 0 22 0 7 0 23 0 8 0 24 0 9 -0 25 0 10 0- 26 0

~

11 0 27 0 12 0 _ 28- 0 0 29 0

-14 0 30 0 15 0-16 0 0449k/10 nrr i,, - _ _,

/m , .

OPERATIrs DATA REPORT d

50-259

' DOCKET NO. .*

PREPARED BY S A. Ratliff TELEPHONE T3D5) 729-2937 OPERATING STATUS Eotes

1. Unit Name: Browns Ferry Unit One
2. Reporting Period: NOVEMBER-1991
3. Licensed Thermal Power (MWt):. 3293
4. Nameplate Rating-(Gross MWe): 1152
5. Design Electrical Rating-(Net MWe):- 1065
6. Maximum Dependable Capacity (Gross MWe): 1098.4
7. Maximum Dependable Capacity (Net MWe): 1065
8. If Changes occur in Capacity ' Ratings (Items Hu:nber 3 Through 7) Since Last Report, Give . Reasons: -

N/A

9. Power Level To Which Restricted, If'Any (Net MWe): N/A
10. Reasons For Restrictions, If Any: N/A This Month Yr-to-Date Cumulative 720 E016 152000
11. Hours in Reporting Perica 0 0 59521
12. Number of Hours Reactor Was Critical 0 6997
13. Reactor Reserve Shutdown Hours 0 0 0 58267
14. Hours Generator On-Line 0 0 0
15. Unit Reserve Shutdown Hours 168066787
16. Gross Thermal Energy Generated-(MWH) 0 0
17. Gross Electrical Energy Generated (MWH) 0 0 55398130

[

18. Net Electrical Energy Generated (MWH) -3077 -23876 53537594 0 0 38.3
19. Unit Service Factor 38.3
20. Unit Availability Factor 0 0 0 0 33.1
21. Unit Capacity Factor (Using MDC Net)
22. Unit Capacity Factor (Using DER Net) 0 0 33.1 l 23. Unit' Forced Outage Rate 100 100 56.3
24. Shutdowns Scheduled Over-Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: To be determined 0449k/11

OPERATING DATA REPORT #

DOCKET NO. 50-260 '.

. PREPARED BY S.A. Ratliff . -

TELEPIIONE (205) 729-2937' ~

Of_ERATING STATUS Notes

1. Unit Name: Browns Ferry Unit Two
2. ' Reporting Eeriod:. NOVEMBER 1991
3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross MWe): 1152
5. Design Electrical Rating (Net MWe): lQ65
6. Maximum Dependable Capacity (Gross MWe): 109S,
7. Maximum Dependable Capacity (Net MWe): 1065
8. If Changes occur in Capacity Ratings (Items Numbet _ through 7) Since Last Report, Give Reasons:

N/A'

9. Power Level To Which 1:estricted,' If Any (Net MWe): N/A
10. Reasons For Restrictions, If Any: N/A This Month Yr-to-Date Cumulative
11. Hours in Reporting i*sriod 720.0 8016.0 146887
12. Number of Ilours Reactor Was Critical 720.0 3945.1 59805
13. Reactor Reserve Shutdown flours 0 0 14200
14. Hours Generator On-Line 720.0 3432.4 57771
15. Unit Reserve Shutdown IIours 0 0 0
16. Gross Thermal Energy Generated (MWII) 2334469.6 9685199.7 162930367
17. Gross Electrical Energy Generated (MWII) 800220.0 3164670.0 53936468
18. Net Electrical Energy Generated (MWII) 781571.0 3044008.0 52095129
19. Unit Service Factor 100.0 42.8 _. 39.3
20. Unit Availability Factor 100.0 42.8 39.3
21. Unit Capacity Factor (Using MDC Net) 101.9 35.7 33.3
22. Unit Capacitr Factor (Using DER Net) 101.9 35.7 33.3
23. Unit Forced Outage Rate 0 56.1 .._J 3 ,8 ..
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At. End Of Report Period, Estimated Date of Startup: N/A 0449k/12

. OPERATING DATA REPORT DOCKET NO. 50-296 -

PREPARED BY S.A. Ratliff .

TELEPHONE (205) 729-2937 OPERATING STATUS Notes

1. Unit Name: Browns Ferry Unit Three
2. Reporting Period: ._ NOVEMBER 1991
3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross MWe): 1152
5. Design Electrical. Rating (Net MWe): 1065
6. Maximum Dependable capacity.(Gross MWe):- 1098.4
7. Maximum Dependable Capacity (Net MWe): . 1065-
8. If Changes Occur in Capacity Ratings' (Items Number 3 Through 7) Since Last Report, Give Reasons: .

N/A

9. Power Level To Which Restricted, If Any (Net MWe): N/A
10. Reasons For Restrictions, If Any: N/A This Month Yr-to-Date Cumulative
11. Hours in Reporting Period 720 8016.0 129312
12. Number of Hours Reactor Was Critical 0 0 45306
13. Reactor Reserve Shutdown Hours 0 0 5150
14. Hours Generator On-Line 0 0 44195
15. Unit Reserve Shutdown Hours 0 0 0
16. Gross Thermal Energy. Generated (MWH) 0 0 131868267
17. Gross Electrical Energy Generated (MWH) 0 0 43473760
18. Net' Electrical Energy Generated (MWH) -1783 -18098 41954438'
19. Unit Service Factor 0 0 34.2
20. Unit Availability, Factor 0 0 34.2
21. Unit Capacity Factor (Using MDC Net) 0 0 30.5
22. Unit Capacity Factor (Using DER Net) 0 0 30.5
23. Unit Forced Outage Rate 100 100 60.8
24. Shutdowns Scheduled Over Hext 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut 'Down At End Of Report Period, Estimated Date of Startup: To be determined 0449k/13

_ . _ _ _ . _ _ - _ _ _ _ _ _ _ _ . _ _ . _ _ _ _ - _ _ _ _ _ - _ c e ~

EMDET NO: 50-259 tMIT., SHUTDOWNS AND POWER REDUCTIONS UNIT NAME: One .

PREPARED BY:$. A. Ratliff' ',

REPORT MONTH: NDVEMBER 1991 TELEPHONE:(205) 729 2937 l l ]Methodof l l- l l Licensee l l 'l CauseandCorrective'l l l l -l Duration l -lShuttingDown l Event' l System lComponenti Action to j lNo. l Date l Type I' l - (Hours ) . l Reason 2

-l Reactor 3

lReportNo. l Code 4 s <

i Code l Prevent Recurrence -l l l 1 l l l l' l I 1

-l-1 I I I 'l 1 l .I I I l-l315 l06/01/85 l F. l 720 l F- l 4 l. l l l Administrative hold to ,l l l l l l l l 9 l l l resolve various TVA and l l l l l l l l 1' l lNRCconcerns. l.

I I i 1 I I  :

i I I I I I 1 I i 'l I I I I I I I I I I l I l- I I I I I I I I I i i l i i l I l- 1 I I I I I i I 1 I I I I I I I I I I I I I I I I I I I i i I I l

I I I I I I I I I I I I I I I I I I 1 i -

I i i i I I I I I I I I i i i I I I I I I I i 1 I i l i l i I I I I I I I I I I I i 1 I 1 I I I I I l i I i i i I I I I I I i i 1 i l l I I I i 1 1 1 1 1 i l l I l l l a

1 I l l l l l l I I l l l l

I:F Forced 2 3 Reason: Method: #

5: Scheduled A-Equinment Failure (Emplain)

Enhibit G-Instructions 1-Manual for Preparation of Cata ,

B-Maintenance or Test 2-Manual Scram Entry sheets for Licensee C-Refueling 3-Automatic Scram Esent Report (LER) File

. D-Regulatory Restriction 4-Continuation of Existing Outage (NUREG-061)

E-Operator Training and License Examination 5-Reduction F-Administrative 94ther G-Operational Error (Emplain) S H-Other (Explain) Exhibit 1-Same Source 0449k i

^

. DOCKET NO: 50-260 - -

UNIT SHtRDOWNS AND POWER RECUCTIONS UNIT hAME: Two COMPLETED BY:5. A. Ratliff ,-

REPORT MONTH: NOVEMBER 1991 . TELEPHONE:(2051 729-2937 s l 1. l l l l Method of l Licensee l l l Cause and Corrective l 3 l l l' l Duration l lShuttingDown l Event [ System l Component l Action to j ';

l No. l: Date l Type I

l(Hours) l Reason 2

l Reactor 3

lReportNo. l Code4 l Code 5

l Prevent Pecurrence l ..

l l l- 'l I 'l l l I l l l 1 I l i I I I i i i INee l l l .l l l l l l l 1 l' I I 1 I l l I I I I I I I I I l- 1 I I I I l I l i I i ' i 1 l I l- 1 I I I I l l l 1 1 I i 1 I i 'l l I I I I I I I I I I I LI I l-1 I I I I I I I i 1 1 I I I I I I I I I I I I I I I I l  !  ! I I I i l I i l I I i i i i 1 I I I I i i i i i l i i l i I I I I I I I I I I I I I i I I i l i i l i i l I i l i i l i i l I I i 1 l l l 1 1 I I I I I I I I I I I I I l l I I I I i i i l 1 1 I i  ! I I I I I I l- i 1 1 I I I I 1-l l l l l I I I I l l 2 Reason: 3 #

I:F Forced Method: Enhibit G-Instructions 5: Schedul ed A-Equipment Failure (Emplain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry sheets for Licensee C-Refueling 3-Automat;c Scram Event Report (LER) File D-Regulatory Restriction 42.ontinuation of Existing Outage (NUREG-061)

E-Operator Training and License Examination 5--Reduc tion F-Administrative 9-Other S

G-Operational Error (Emplain) Enhibit I-Same Source H-Other (Esplain) 0449k

.c c DOCKET NO: 50-296-

' UNIT SIUTDOWNS AND POWER REDUCVIONS' UNIT NAME: Three ..

REPORT MONTH:

COMPLETED BY:5. A. Ratliff -

NOVEMBEtt 1991 TELEPHDNErf205) 729-2937 l l l .

l l lNethodof' l Licensee l l .l l l l l Duration l Cause and Corrective' l lShuttingDown l Event l System lNo. l Date l Type I l(Hours) 'l Reason 2 l Component l Action to l l 1 I l Reactor. lReportNo. l Code 4 l Code 5

l Prevent Recurrence I I I' l l' l I i 1 l- 1 I 1 l I I I l157. l03/03/85 l F l'720 l. F. 4 I i 1 l l l .]

l l l l [

l Administrative hold to .l l l l l 1 1 1 l lresolvevariousTVAand'l

!- 1 I I I i 1 INRc coaceras.'

I I I I i I i i I i I i l i I l I I I i i i i l I i i i l l- 1 I I I I I I I I I i I 1 I i i i l 1 I I i i I l-l I I i 1 I i i i i 1 I i i  !

i l l I 'l I i i I I I i 1 i i i i I i I 'l i I I l i 1

i I I I I l i l I I I 1 I l I i

_l i i I i 1

I I I i i i I I I I 1 i i i i l i 1 i i i i I I I I I I i i  ! I I

i I I l i 1. I I I i

I I I I I i 1 1 1 I 1 1 I I I I I I I I I I l 1 'I i l i 1 1 l l l I

1 I I l F: Forced ' Reason:

" Method: #

S. Scheduled A-Equipent Failure (Explain) Exhibit G-Instructions 1-Mar.ua'l BWintenance or Test for Preparation of Data 2-Manual Scram Entry sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction '

4-Contircation of Existing Outage (NUREG-061)

E-Operator Training and License Esasination 5-Reduction F-Administrative 94ther G-Operational Error (Explain) S H-Other (Explain) Enhib?t I-Same Source 0449k/

_ _ _ _ . _ . _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ . _ _ _ _ _ _ . _ . _ _