Janusry 25. 1974 Mr. Jaiec P. O'Reilly, Director p
United Sintes f.temic Encyc/ onniccicn C
Directorate of Recult. tory Operations M,g, d.
631 Park Avenue King of Pruccin. Ferairylvania 1946 Subiect:
Abnor-J Occurrence 24-Rour florification Confirning cy telephone convercation with Mr. R. A. Feil, A.E.C. Region 1 Reguistory Operations of: ice on January 25. 1974.
Referenec: Licence !!urber DPR-44, A.,endnent Number 1, Technical Specification Table 31.1 Report 1lo.
50.277-74-3 Report Date:
1/25/74 Occurrence Date:
1/25/74 Facility:
Peach Botto: Ato:ic Power Station - Unit 2 R.D.1, Delta, Penncylvania 17314 Identification of Occurrence:
Elcetrical fault on E-4 Diesel Generator current trarefomera.
Conditions Prior to occurrence:
i 0
Renetor criticci, very lov pe"er, vented at 160 F reactor coolant torporature.
Description of Occurrence:
Relays initiated generator trip during a surveillance test.
Designatica of' Apparent Cause of Occurrence:
~
Fault cauced by high water level in cable chase.
Analycic of Occurrence:
E1 h water level due to seepage into cable chace area of water 5
draining to ficer drain from defective leaking ete r cyste:
condennate return purp.
^
Corrective Action:
Drain cabic chase. Replace current transforcers. Enke applicable electrical tectc. Co plete curroillence testa.
Assure that cabic chnee cannot ' fill with vnter in the future.
Failure Date:
I;o previous.
,1
+
A V. T. Ullrich, Superintendent '
'),
Peach Botto. Atomic Power Station
[* t <,b'q*
8402070111 740204 PDR ADOCK 05000277 S
~
O O
MEMO ROUTE SLIP 5 a m * * '<~ ' "' * -
' a' c aac "*
- c '-
Fa' ac t'ca.
e o,,,,
u r..,
< 8,. u.g 4. e,i,, w sio2.o eu,,. 4.....
,,,,,1, r o, i,,,-..
i 1o e.+..a o.o
...n.ts R M..
s l
ROChief,FS&I/>
PIIIIADELPilIA ELECTRIC CO.
RO:llQ (4)
/
RO Files Dan PEAcil BOITOM 2 DR Central Files Directorate of A0 74-3 To c...,a.e.n mitm.3 RtM Ras Licensing (4)
The above A0 is forwarded for information.
OCC Distribution will be made by this of fice Dart to the PDR, Local PDR, NSIC, 17FIE, and State T O P.ame anJ watt)
INTIAL5 REMARKS Representatives.
DATE F ROM (N.m, and unit)
REMARKS a'<. n js y
s w-p, v
II. J. Brunner Region I PHONE pedL DATE 8-337-1246 1/29/74 USE OTHER SIDE FOR ADD 4flomaL REM APK$