hp u
Afp
~
LADELPHIA ELECTRIC COMPANY Peach Bottom Atomic Power Station Delta, Pennsylvania 17314 September 20, 1974 Mr. James P. O'Reilly, Director United States Atomic Energy Com:nission Directorate of Regulatory O'pc:ations
,C - [., -.
3-631 Park Avenue 6[M
,;,C1N; King Of Prussia, Pennsylvania 19406 Rg
Subject:
Abnor=al Occurrence 24-Hour Notification PMf J.?;., " k Confirming R. S. Fleischmann's phone conversation with Mr. Walt Baunack.
-[ f!.f A.E.C. Region 1 Regulatory Operations Office on September 20, 1974.
7.s
?&.W
&y W
Reference:
License Number DPR-44, Amendment Number 1 Technical Specification 3.2.B hy.]
Report No.:
50-277-74-41 Y.J.Q'],
- !c Report Date:
September 20, 1974 hg-.Q Occurrence Date:
September 19, 1974 Facility:
Peach Bottom Atomic Power Station
+ -
k,p.'.1$
R. D. 1, Delta, Pennsylvania 17314
,.,-p'l-Identification of occurrenca:
ME ri Setpoint of HPCI ateam line high flow sensor outside of Technical Specification limits.
Conditions Prior to Occurrence:
The reactor was at 80% power.
g Description of Occurrence:
During a routine instrument calibration eurveillance test, the setpoint of one of the EPCI' ateam line high flow sensors, DPIS-2-23-76, was found to have drifted outside the limita allowed by the Technical Specifications. The prescribed setpoint for this 3g a device is less than or equal to 225 inches H 0.
The device was found to trip at Q jf 2
231 inches H20.
hg f 4 9jV U kM(i'~
W' Designation of Apparent Cause of Occurrence:
[
A careful examination of the subject switch revealed no evidence of binding or other mechanical calfunction. The switch tripped consistently at 231 inches B 0.
This 3fg,',
2 setpoint failure is attributed to setpoint drif t only.
9,W '.;',
.t.
l
%'h Analysis of Occurrence:
i The HPCI steam line high flow isolation signal circuitry is arranged in a one out d
of two configuration. A high flow signal from either of the two differential pressure devices is sufficient to cause an isolation of the HPCI steam supply.
gh,y A
=
Due to the s=sil magnitude of the setpoint shift and the fact that the device was n.I. Q.
functional,,this occurrence has a minimal effect on plant safety.
j0gy k,.,,
- -wmu.
Corrective Action:
i The subject device was imediately recalibrated to within acceptable limits and returned to service. The calibration of the companion switch was checked and found to be satisfactory.
8401270046 740929 m
=
i PDR ADOCK 05000277 i
Failure Date:
S PDR j