ML20086H652

From kanterella
Jump to navigation Jump to search
Telecopy AO 75-49:on 750806,leakage Found from Feedwater Check Valve 6-96A.Cause Under Investigation.Valve Being Repaired & Will Be Tested
ML20086H652
Person / Time
Site: Peach Bottom 
Issue date: 08/08/1975
From: Ullrich W
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
AO-75-49, NUDOCS 8401190512
Download: ML20086H652 (1)


Text

9 s

3

)

j l

PHILADELPHIA ELECTRIC CCMPA5Y Peach Botten Atc=ic Power Station Delta. Pennsylvania v'

17314 August 8, 1975

)' ~, s oj' h Kr. Ja:es P. 0*Reilly, Director Office or Inspection and Enforcecent

]gg dhdu:R Region 1 United States Suelear Regulatory Coc=ission 631 Park. Avenue King of Prussia, Pennsylvania 19aC6 S ub.i e ct :

Ab no rr.n l Oecurrence 2t-Hour notifiestien Confir=ing 3.

C.

Scith's conversation with Mr.

k* alt Baunact, Region i United States Nuclear Regulatory Conmicsion on August 7, 1975

Reference:

License Nu=ter OPR-56 Tectntesi 0, w s ' ri cati e-Ocfc.;ner:

3.7 5_1 g---

' R eport 7o.T S cr-278-75-L 9 Report Date:

AGEust 7, 1975 Occurrence Date:

August 6, 1975 Facility :.

Peach Botton Atomic Power Station R.D.

1. Delta, Pennsylvania 1731L Identification of Occurrence:

Leakage from feedvater check valve 6-96A (outboard)..

Conditions Prior to Occurrence:.

Unit critical, starting.up.

Description.of Occurrence:

Water was found to be leaking from the bonnet joint on the outboard feedvater check valve 6-96A.

Designation of Apparent Cause of Occurrence:

Under investigation Analysis of Occurrence:

The safety inplication of this occurrence is minimal,sinie under normal, conditions, the leak. is feedwater, and depressurization and' shutdown was. initiated when the leak was discovered.

l Corrective Action:

l The failure is being repaired and will be tested.

t Failure Data:

A previous failure was repdrted as A0-277-75 L3 i

l Very truly'yours, 9 N kWJ" W.

T.

Ullrich. Superintendent Peach Botton Ato:ic Power Station l

8401190512 750808 PDR ADOCK 05000278 S

PDR

' ^

~ hwn

===_.

t l

,-..n r