ML20086G983

From kanterella
Jump to navigation Jump to search
AO 75-15:on 750222,hydraulic Snubber on HPCI Steam Line Found W/Empty Reservoir.Cause Under Investigation.Source of Leakage Could Not Be Identified.Snubber Reservoir Refilled
ML20086G983
Person / Time
Site: Peach Bottom 
Issue date: 03/04/1975
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Anthony Giambusso
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20086G986 List:
References
AO-75-15, NUDOCS 8401130162
Download: ML20086G983 (2)


Text

_ __

PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET PHILADELPHIA PA.19101

'o.

(21518414000 tI

./g

~~

.,.\\

,a March h,1975 Mr. A. Gianbusso, Director Division of Reactor Licensing Office of Nuclear Reactor Regulations United States Nuclear Regulatory Cct=tission Washington, D.C.

20555

Dear Mr. Gimbusso:

Subject:

Abnomal Occurrence The following occurrence was reoorted to Mr. Tcet Shedlowsk,

/

Office of Inspection and Enforcement, Regien 1, United States Nuclear Regulator / Comnission on Febraary 22,1975 Written notification uns r.ade to Mr. Jees P. O'Reilly. Office of Tntipm+.4 nn.and W ra-a-t, Region ], United States Nuclear Regulatory Ccaniscion on February 2h, 1975 In accordance with Section 6.7.2.A of the Technical Spccifications, Appendix A of DFR-56 for Unit 3 Peach Botton Atomic Pctier Station, the following report is being submitted to the Directorate of Reactor Licensing es an Abnomal Occurrence:

Reference:

License Nunber DPR-56 Tcchnical Specification

Reference:

h.11.D.1 Repcrt No.:

50-278-75-15 Report Date:

March h,1975 Occurrence Date:

February 22, 1975 Facility:

Peach Botton Atcnic Power Station R.D.1, Delta, Pennsylvania 1731h Identification of Occurrence:

Incperable hydraulic snubber on HPCI Stean line.

Conditions Prior to Occurrence:

Reactor shutdcun; naintenance outage in progress.

i 2554 8401130162 750304 gDRADOCK05000

Y, e Mr. A. GitnbussoA O

r ce 2 March h, 1975 V

Descrintien of Occurrence:

A routine inspection of Unit 3 dr;/well hydraulic snubbers during an cutage identified snubbers 3-23 DM 5-23 as having an cr:pty i

reservoir.

Desirmation of Apparent Cause of Occurrence:

The cause of the enpty snubber reservoir is under investigation.

Analysis of Occurrence:

No danage of piping or supports was noted during the inspection.

Safety inplications are, therefore, minimal.

Corrective Action:

The source of Icakage from the snubber could not be identified.

j The snubber reservoir was refilled. This snubber shall again be inspected the next time access to the drywell is available.

i Failure Data:

Additienc1 hydrculic snubber difficulties were reported as j

A0-5-277-7h-h5, 50-278-7h-3h, A0-50-278-7h-16, A0-50-278-7h-8.

Very truly yours, h /h M. '. Cooncy 1

As 't Gen'l Superintendent

  • Generation Division cc:

Mr. J. P. O'Reilly Director Office of Inspection and Enforcer.cnt I

Region 1 United States Nuclear Regulatory Connission 631 Park Avenue King of Prussin, PA 19h06 a.

-